Search NASA⌕ Search

SEARCH · Search NASA

Results for “RESIDENTIAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Technology inventory: energy efficiency measures for residential, commercial, and industrial sectors in the United States

Energy efficiency is expected to continue to be one of main levers for governments to address the energy and climate crisis. While a diverse mix of energy efficiency programs has been regarded as an important part of governmental actions, an energy efficiency policy or program needs to identify and assess eligible savings measures, i.e., specific technologies or practices, for designing key features, e.g., target type, target stringency, covered load, and cost recovery. This report briefly discusses U.S. energy efficiency policies and programs, explores publicly available resources of energy efficiency measures for residential, commercial, and industrial sectors in the U.S., and describes how to compile key measures and characteristics into an integrated spreadsheet database. The database in the initial version offers, for more than 1,200 measures, efficiency or improvement potential, technical notes, costs at a given year, where applicable. Energy efficiency measures compiled here could play an important role in determining savings targets and target stringency under a potential energy efficiency policy such as an energy efficiency resource standard in Korea, and offer significant opportunities for energy efficiency improvement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential HVAC Installation Practices: A Review of Research Findings

This report summarizes relevant findings from available literature and research that were evaluated to better quantify the potential benefits of improving current installation practices for heating, ventilation, and air conditioning (HVAC) equipment in existing homes (i.e., equipment replacements). Although some of the findings may be informative and applicable to the new construction market, this report focuses on analyses specific to the single-family residential HVAC replacement market. The research findings summarized in this report reveal that improving the installation of central heating and air conditioning systems has the potential to decrease operating and maintenance costs, decrease equipment purchase price, improve indoor air quality and overall indoor comfort, and reduce household energy consumption by mitigating a variety of common system performance issues.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Residential HVAC Installation Practices: A Review of Research Findings

This report summarizes relevant findings from available literature and research that were evaluated to better quantify the potential benefits of improving current installation practices for heating, ventilation, and air conditioning (HVAC) equipment in existing homes (i.e., equipment replacements). Although some of the findings may be informative and applicable to the new construction market, this report focuses on analyses specific to the single-family residential HVAC replacement market. The research findings summarized in this report reveal that improving the installation of central heating and air conditioning systems has the potential to decrease operating and maintenance costs, decrease equipment purchase price, improve indoor air quality and overall indoor comfort, and reduce household energy consumption by mitigating a variety of common system performance issues.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterize the Demand and Energy Characteristics of Residential Electric Vehicle Supply Equipment

The EV Project enrolled over 8,000 residential participants. These participants purchased or leased a Nissan Leaf or Chevrolet Volt. The EV Project provided and installed Blink Electric Vehicle Supply Equipment (EVSE), used to recharge their PEV, in exchange for their agreement to allow project analysts to evaluate data collected from charging their PEV at their residence and away from home. The power required to recharge a PEV can be a significant contributor to the electrical load a residence places on the electric grid. What insight can The EV Project data provide in characterizing this contribution in terms of power demand and energy consumption to assist electric utilities in PEV adoption planning?

33 ADVANCED PROPULSION SYSTEMS↗

Non-residential Electricity Prices: A Review of Data Sources and Estimation Methods

This paper presents a review of electricity price data sources and estimation methods for non-residential consumers, including a detailed empirical study of tariff-based prices collected as part of Lawrence Berkeley Lab's Tariff Analysis Project (TAP). We compare the TAP data to two other data sources: utility-level annual sales, revenues and consumer counts published by the Energy Information Administration (EIA), and the Typical Bills reports published by the Edison Electric Institute. A brief overview of the types of rate structures included in the TAP database illustrates the often complex relationship between the consumer's energy use and the costs they see on their electricity bills. We provide mathematical definitions of the different types of electricity price that are useful in cost-benefit analysis, construct estimation methods appropriate to each data set, compare the results, and evaluate the relative strengths and weaknesses of each approach. We also examine how price variation is driven by differences in season, region, industry business model, and variables characterizing consumer energy use. Tables of regional price estimates for each data source, based on 2015 data, are included in the Appendix to this paper.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Life Cycle Assessment of Future Photovoltaic Electricity Production from Residential-scale Systems Operated in Europe

The photovoltaics (PV) industry is growing rapidly to meet the increasing demand of green power. As the industry grows, the manufacturing processes and the material and energy efficiencies of PV cells and panels are improving. To assess the impacts of this trend, future scenarios of single-crystalline (single-Si, also known as mono-crystalline) silicon and cadmium-telluride (CdTe) PV systems installed on European residences were established. Assessment of the improvement potential of PV electricity-generating technologies such as single-Si and CdTe could be considered in long-term energy strategy decisions. This study aims to provide scenario-based information about the environmental per-formance of single-Si and CdTe PV modules produced and operated in the far future (2030 to 2050). The deployment application assessed considers European residential roofs. We made scenario-dependent projections of key parameters for single-Si and CdTe PV panels manufactured in 2050. The parameters included cell efficiency, module efficiency, wafer thickness, cutting losses, kerf losses, silver use, glass thickness and operational lifetime. This study combines developments for these parameters with projections of the environmental performance of electricity mixes in the main manufacturing countries/regions (European Union, China and the United States of America) and with projections of the environ-mental performance of basic material production (aluminium, copper, magnesium, nickel, pig iron, zinc, clinker and flat glass) in the far future. The three scenarios used in the assessment of future PV electricity were categorized into three classes: 'business as usual' (BAU), 'realistic improvement' (REAL) and 'optimistic improvement' (OPT). It estimates the current life cycle greenhouse gas emissions of single-Si PV electricity produced on the roofs of European residences to be approximately 80 grams CO2-equi-valent per kWh (g CO2-eq per kWh). Based on the projected changes to key parameters and the background system, life cycle greenhouse gas (GHG) emissions could be reduced to 65% (scenario BAU), 31% (scenario REAL) and 18% (scenario OPT) of that value in the far future. Results for other life cycle assessment (LCA) metrics are also assessed in this study such as: non-renewable cumulative energy demand, acidification potential, human toxicity potential, photochemical ozone creation potential, particulate matter formation potential, and land use. We calculated the total energy payback time (EPBT) and the non-renewable energy payback time (NREPBT) in the far future of single-crystalline silicon-based PV panels operated in Europe by dividing the estimate of non-renewable cumulative energy demand of PV electricity for the given scenario by the non-renewable cumulative energy demand of the scenario-dependent national and regional non-renewable residual electricity mixes. The study estimates the payback time could be reduced from 2.4 years today to 1.7, 1.2 and 1.2 years (scenarios BAU, REAL and OPT, respectively) in the far future, based on the assumptions and projections in the analysis. It finally estimates the current life cycle greenhouse gas emissions of CdTe PV electricity produced on the roofs of European residences to be approximately 30 g CO2-eq per kWh. Based on the projected changes to key parameters and the background system, life cycle GHG emissions could be reduced to 70% (scenario BAU), 44% (scenario REAL) and 32% (scenario OPT) of that value in the far future.

14 SOLAR ENERGY↗

Low-GWP Refrigerant Evaluation in AC Systems for High Ambient Temperature Applications – Acquire Nortek Residential AC/HP Units for Evaluation and Model the Units Using HPDM

For the upcoming refrigerant transition from HFCs to minorly flammable HFO refrigerants (A2L), refrigerant charge reduction is important to mitigate the fire hazard. Microchannel heat exchangers (MHXs) are a mature technology, which is effective in reducing system charge while maintaining similar heat transfer performance. MHXs will be applied more widely when the new refrigerants are used. Prior studies of the A2L HFO blends were mostly focused on fin-and-tube coils (FTC). An in-depth study for an air conditioner (AC)/heat pump (HP) system using all microchannel heat exchangers is still lacking. In FY19, a side-to-side comparison will be conducted between two residential split heat pumps, one using all FTCs and the other using all MHXs for drop-in investigation, to identify potential issues for future design. The two heat pumps have similar rated capacity, SEER, HSPF levels, similar fan, blower and compressor, but differ in heat exchangers. Both the HPs use two-stage compressors to facilitate investigating different refrigerant flow rates. We will drop-in HFO refrigerants (replacements for R-410A, e.g. R452B, R447B, R32, etc.). The experiments will reveal the potential of MHXs for charge reduction, and how the two systems using A2L refrigerants operate under standard SEER and HSPF rating conditions. The two units were donated by our partner, i.e. Nortek Global HVAC, an industry leader in making heat pumps using all MHXs as well as FTCs. The units were shipped to ORNL this week, and the product design data were also shared for modeling the two units using HPDM.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Risk Assessment of Catastrophic Leak Of R-452b From Package Unit into A Residential Space

With the effort to find alternative refrigerants with lower global warming potential (GWP), challenges have arisen due to the flammability risk for many of the alternatives. One of the new alternatives is R-452B, which is recommended as a replacement for R410A. R-452B is classified as a mildly flammable refrigerant (A2L) by ANSI/ASHRAE Standard 34. This paper summarizes a computational fluid dynamic (CFD) simulation study of a leak incident of R-452B from a 3-ton packaged unit which serves a 167 m 2 residence. The R-452B leak is assumed to be downstream of the evaporator coil. The simulated residence has four rooms and a hallway. The packaged unit distributes the conditioned air through a supply duct system delivering the air through registers. The dispersion of R-452B is characterized for two scenarios: one with underfloor supply air ducts and another with ceiling supply air ducts. The mass flow rate of R-452B exiting the duct outlets is quantified and the refrigerant volume fraction is monitored inside the residential space.

42 ENGINEERING↗

Tracer gas test in Net-Zero Energy Residential Test Facility

The Net-Zero Energy Residential Test Facility (NZERTF) at NIST was built in 2012 to support the development and adoption of cost-effective net-zero energy designs, technologies, and construction methods. It is two-story, and has four bedrooms, three bathrooms, and an open living room, dining room, and kitchen space. The NZERTF also has a basement and attic, both located within the conditioned space because the thermal and air-moisture barriers encompass the basement walls and attic roof. Transfer grilles link the living spaces to these two zones. The central heating and cooling system includes an air-toair heat pump, which delivers air to the basement, first and second floors. The heat pump has a cooling capacity of 7.6 kW and a heating capacity of 7.8 kW. The indoor unit is in the basement and ductwork runs along the basement ceiling. A balanced heat recovery ventilator (HRV) is installed in the basement and has its own dedicated ductwork. The HRV supplies 47 L/s of outdoor air to the house, with supplies on the first floor (in the kitchen/dining area) and in each of the three second-floor bedrooms. Air from the first-floor bathroom and both second-floor bathrooms is returned to the HRV before being exhausted, though the HRV was turned off during the tests. The house also has a range hood exhaust and a clothes dryer exhaust, both of which were turned off for the tests. The temperature of the house was measured and the operation of the space conditioning system, including its recirculating air distribution fan, were controlled by a commercially available thermostat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FY20 Third Milestone Report for Advanced Techno-Economic Modeling for Geothermal Heat Pump Applications in Residential, Commercial, and Industry Buildings

This report summarizes the developments of an integrated simulation program for enabling simulation, auto-sizing, and optimization of geothermal heat pump systems. This work fulfills the following FY20 third milestone for WBS 2.5.5.3: Advanced Techno-Economic Modeling for Geothermal Heat Pump Applications in Residential, Commercial, and Industry Building.

15 GEOTHERMAL ENERGY↗

Effects of EMP Testing on Residential DC/AC Microinverters

Electromagnetic pulse (EMP) coupling into electronic devices can be destructive to components potentially causing device malfunction or failure. A large electromagnetic field generated from the EMP can induce large voltages and currents in components. As such, the effects of EMP on different devices needs to be understood to elucidate the effect of EMP on potentially vulnerable systems. This report presents test results for small-scale residential DC to AC solar panel microinverters that were subjected to high voltage impulses and currents. The impulses were intended to emulate an EMP coupling event to the AC and DC sides of the microinverter. State-of-health measurements were conducted to characterize device performance before and after each test.

42 ENGINEERING↗

Alabama Residential Energy Code Field Study: Baseline Report

A research project in the state of Alabama identified opportunities to reduce homeowner utility bills in residential single-family new construction by increasing compliance with the state energy code. The study was initiated in March 2014 and continued through May 2014. During this period, research teams visited 134 homes during various stages of construction, resulting in a substantial data set based on observations made directly in the field. Analysis of the data has led to a better understanding of the energy features present in homes, and indicates nearly $1.3 million in potential savings to Alabama homeowners that could result from increased code compliance. Public and private entities within the state can use this information to justify and catalyze future investments in energy code training and related energy-efficiency programs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Arkansas Residential Energy Code Field Study (Baseline Report)

A research project in the State of Arkansas identified opportunities to reduce homeowner utility bills in residential single-family new construction by increasing compliance with the state energy code. The study was initiated in May 2015 and continued through October 2015. During this period, research teams visited 226 homes during various stages of construction, resulting in a substantial data set based on observations made directly in the field. Analysis of the data has led to a better understanding of the energy features present in homes, and indicates over $300,000 in potential annual savings to Arkansas homeowners that could result from increased code compliance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Savings Analysis: 2018 IECC for Residential Buildings

DOE and Pacific Northwest National Laboratory (PNNL) conducted a technical analysis to determine energy savings for the 2018 IECC residential provisions relative to the previous edition, the 2015 IECC. This report documents the methodology used to conduct the analysis and summarizes the results and findings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Georgia Residential Energy Code Field Study: Baseline Report

A research project in the State of Georgia identified opportunities to reduce homeowner utility bills in residential single-family new construction by increasing compliance with the state energy code. The study was initiated in April 2015 and continued through November 2015. During this period, research teams visited 216 homes during various stages of construction, resulting in a substantial data set based on observations made directly in the field. Analysis of the data has led to a better understanding of the energy features present in homes, and indicates over $3 million in potential annual savings to Georgia homeowners that could result from increased code compliance.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Determination for the 2006 International Energy Conservation Code, Residential Buildings (Technical Support Document)

The Energy Conservation and Production Act of 1976, as amended, requires the U.S. Department of Energy (DOE) to determine whether revisions to the 2006 International Energy Conservation Code (IECC) would improve energy efficiency in residential buildings. An “affirmative determination” for any IECC revision triggers a requirement that each state certify to DOE, within two years of the publication of the determination, that it has reviewed the provisions of the new code and made a determination whether it is appropriate to update its building code(s) to meet or exceed the revised IECC.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy Use Savings for a Typical New Residential Dwelling Unit Based on the 2009 and 2012 IECC as Compared to the 2006 IECC

The 2009 and 2012 International Energy Conservation Codes (IECC) require a substantial improvement in energy efficiency compared to the 2006 IECC. This report averages the energy use savings for a typical new residential dwelling unit based on the 2009 and 2012 IECC compared to the 2006 IECC. Results are reported by the eight climate zones in the IECC and for the national average.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Idaho Residential Energy Code Field Study

A research project in the state of Idaho identified opportunities to reduce homeowner energy costs in residential single-family new construction by increasing compliance with the current state energy code. The study was initiated in January 2018; data collection began in March 2018 and continued through June 2018. During this period, research teams visited 127 homes during various stages of construction, resulting in a collection of data based on observations made directly in the field. Analysis of the data has led to a better understanding of the energy features present in homes and indicates nearly $500,000 in potential annual savings to Idaho homeowners that could result from increased compliance with the Idaho Energy Conservation Code.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗