Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reliability Target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Measurement of the Kaon Production Normalization in the NuMI Target Using Uncontained Charged-Current Muon Neutrino Interactions in the NOvA Far Detector

aNOvA is a long-baseline neutrino oscillation experiment that uses the NuMI beam from Fermilab. Its physics goals include providing constraints to the neutrino mass hierarchy and the CP-violating phase $\delta$ by precision measurements of the electron (anti)neutrino appearance in a muon (anti)neutrino beam. Similarly, new limits on the values of $\sin^2{\theta_{23}}$ and $\Delta m^{2}_{32}$ will be achieved by measurements of the muon (anti)neutrino disappearance probabilities. A combined analysis measurement will allow a better resolution of the $\theta_{23}$ octant. The NuMI beam is produced by the collision of high energy protons into a target, giving rise to kaon and pion mesons that decay to neutrinos of a specific flavor. This thesis presents a measurement of the kaon production normalization scale using uncontained charged-current muon neutrinos at the Far Detector. Because the neutrino beam is not pure in flavor, it contains an admixture of other different n eutrino flavors that become a source of background. %in oscillation analysis. Therefore, it is of paramount importance for accelerator experiments, such as NOvA, to have a reliable flux prediction of the neutrino beam in order to achieve its physics goals. One method to constrain the flux is to constrain and measure each flux component independently. The kaon component contributes to the intrinsic $\nu_{e}$ contamination of the beam, a key background for the $\nu_{e}$-appearance analysis. We observed that the uncontained sample in the 10-20 GeV region corresponds to the kaon component of the NuMI beam at the Far Detector. We also found a 60-80\% correlation between the Near Detector $\nu_{e}$ background and the Far Detector $\nu_{\mu}$ uncontained signal. The data used for this analysis was collected from October 2014 to February 2017, corresponding to $7.99 \times 10^{20}$ protons-on-target (POT). The ratio between the Far Detector data and the simulation is fitted to a lin e in the 10-20 GeV energy region. Calibration, energy scale,! final state interactions and neutrino flux (e.g. beam transport and hadron production shape only) systematic uncertainties are considered. The kaon production normalization scale is measured to be $S_{K} = 1.07 \pm 0.16$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Preliminary Analysis of Nuclear-Powered Data Center Scenarios

This report provides a comprehensive analysis of the potential for nuclear energy to meet the growing energy demands of data centers (DCs). It evaluates the technical, economic, and socio-environmental implications of coupling Nuclear Power Plants (NPPs) with DCs, providing initial responses to several key research questions: What is the potential increased energy demand from DCs in the U.S., in the short, medium and long term? The U.S. is experiencing a rapid increase in energy demand from DCs, with projections indicating a total increase of 24-74 GWy(e) by 2028. Meeting this demand with nuclear energy would require 27–85 GWe of installed capacity. While this surge is expected to slow in the long term, the DC industry needs reliable, scalable, and clean energy sources. How much nuclear capacity can be deployed to meet DC demand and in which timeframe? Several pathways for increasing nuclear capacity were identified, including uprates, restarts of recently retired reactors, power purchase agreements with existing fleet, and new construction. Approximately 20‒28 GWe of nuclear capacity could be dedicated to DCs by the early 2030s. How much High Assay Low Enriched Uranium (HALEU) would be needed to support some nuclear deployment scenarios for DCs? Meeting the deployment targets announced by Google and Amazon for the Kairos Power Fluoride-Salt-Cooled High-Temperature Reactor or KP-FHR (~500 MWe by 2035) and the Xe-100 (~1 GWe by 2040), respectively, requires ramping up 19.75% enriched HALEU production to ~6 t/yr by 2040. What types of nuclear energy/DC coupling options exist, and what are the different benefits/challenges? Five coupling options were analyzed, ranging from grid-connected configurations to colocated, behind-the-meter setups. Key design considerations include the proximity to high- and/or medium-voltage transmission lines, the desired internal fault tolerance, and the sources of alternative/backup power during outages. Each coupling option offers unique benefits and challenges in terms of reliability, system costs, regulation, timeline, etc. A list of NPP/DC deployment scenarios was developed, considering existing or newly built NPP or DC projects. Colocated DCs with new small modular reactors or large reactors on greenfield and brownfield sites are the focus of this report. What types of reactors, especially what size, may be incentivized by DCs? Reactor sizing optimization revealed that the ideal reactor size and number of units depend on DC demand, coupling configurations defined in this report, and other economic factors. Larger reactors are preferred for high-demand DCs and grid-connected systems, while larger number of smaller reactors are better suited for DC configurations without grid backup. Which sites may be compatible with co-located nuclear-powered DCs? Siting those projects is a complicated evaluation factoring local water resources, grid connection availability and reliability, IT infrastructure, local work force, proximity to population zones, etc. For this effort greenfield and brownfield sites such as retired coal-fired plants were used to evaluate this question. This evaluation is not meant to recommend any particular site but it highlights key siting criteria and demonstrates large-scale site availability. What are the socio-economic impacts of co-located nuclear-powered DCs? Those projects generate substantial economic benefits to the local economy, particularly in urban settings. Hyperscale DCs colocated with nuclear power plants (sized around 1 GW of power) can create nearly 1,700 jobs for annual operations and more than 7,300 jobs among the supply chain and local businesses as a result of increased household spending. Rural projects also provide significant benefits, but at lower magnitudes compared to urban deployments.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

RESULTS FOR THE FIRST QUARTER 2011 TANK 50 WAC SLURRY SAMPLE: CHEMICAL AND RADIONUCLIDE CONTAMINANT RESULTS

This report details the chemical and radionuclide contaminant results for the characterization of the 2011 First Quarter sampling of Tank 50 for the Saltstone Waste Acceptance Criteria (WAC). Information from this characterization will be used by Waste Solidification Engineering (WSE) to support the transfer of low-level aqueous waste from Tank 50 to the Salt Feed Tank in the Saltstone Facility in Z-Area, where the waste will be immobilized. This information is also used to update the Tank 50 Waste Characterization System. The following conclusions are drawn from the analytical results provided in this report: (1) The concentrations of the reported chemical and radioactive contaminants were less than their respective WAC targets or limits unless noted in this section; (2) The reported detection limit for {sup 59}Ni is above both the requested limits from Reference 2 and the established limits in Reference 3; (3) The reported detection limit for {sup 94}Nb is above the requested limit from Reference 2; however, it is below the established limits in Reference 3. This is a change from previously reported results; (4) The reported concentration of {sup 242m}Am is above the target in Listed in Attachment 8.4 of the Saltstone WAC. This is a change from the previously reported results; (5) {sup 247}Cm and {sup 249}Cf are above the requested limits from Reference 2. However, they are below the limits established in Reference 3; (6) The reported detection limit for Norpar 13 is greater than the limit from Table 4 and Attachment 8.2 of the WAC; (7) The reported detection limit for Isopar L is greater than the limit from Table 3 of the WAC; and (8) Isopar L and Norpar 13 have limited solubility in aqueous solutions making it difficult to obtain consistent and reliable sub-samples. The values reported in this memo are the concentrations in the sub-sample as detected by the instrument; however, the results may not accurately represent the concentrations of the analytes in Tank 50.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Planning Study Comparison of Real-Time Target Tracking and Four-Dimensional Inverse Planning for Managing Patient Respiratory Motion

Purpose: Real-time target tracking (RT-TT) and four-dimensional inverse planning (4D-IP) are two potential methods to manage respiratory target motion. In this study, we evaluated each method using the cumulative dose-volume criteria in lung cancer radiotherapy. Methods and Materials: Respiration-correlated computed tomography scans were acquired for 4 patients. Deformable image registration was applied to generate a displacement mapping for each phase image of the respiration-correlated computed tomography images. First, the dose distribution for the organs of interest obtained from an idealized RT-TT technique was evaluated, assuming perfect knowledge of organ motion and beam tracking. Inverse planning was performed on each phase image separately. The treatment dose to the organs of interest was then accumulated from the optimized plans. Second, 4D-IP was performed using the probability density function of respiratory motion. The beam arrangement, prescription dose, and objectives were consistent in both planning methods. The dose-volume and equivalent uniform dose in the target volume, lung, heart, and spinal cord were used for the evaluation. Results: The cumulative dose in the target was similar for both techniques. The equivalent uniform dose of the lung, heart, and spinal cord was 4.6 {+-} 2.2, 11 {+-} 4.4, and 11 {+-} 6.6 Gy for RT-TT with a 0-mm target margin, 5.2 {+-} 3.1, 12 {+-} 5.9, and 12 {+-} 7.8 Gy for RT-TT with a 2-mm target margin, and 5.3 {+-} 2.3, 11.9 {+-} 5.0, and 12 {+-} 5.6 Gy for 4D-IP, respectively. Conclusion: The results of our study have shown that 4D-IP can achieve plans similar to those achieved by RT-TT. Considering clinical implementation, 4D-IP could be a more reliable and practical method to manage patient respiration-induced motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rapidly Assessing the Quality of Targeted Proteomics Experiments through Monitoring Stable-Isotope Labeled Standards

Selected reaction monitoring (SRM), also known as multiple reaction monitoring (MRM), is a data acquisition technique used in targeted analysis of molecules, including targeted proteomic studies. It exploits the unique capability of triple-quadrupole (QQQ) mass spectrometers to monitor the predefined precursor and fragment ion pairs of specific molecules of interest throughout a liquid chromatography (LC) elution profile. Compared to shotgun proteomics, targeted proteomics using SRM has high selectivity, high sensitivity, and a wide linear dynamic range,(1-3) which makes it especially useful in the accurate and reproducible quantification of low-abundance proteins in highly complex biological samples. SRM has been widely used in the fields of biomarker discovery,(4-7) analysis of protein post-translational modifications(8) and characterization of biological protein networks.(4,9) In the recent years, multiple technical advances have greatly improved the throughput of SRM analyses, allowing for the quantification of hundreds of peptides in a single analysis.(6,7,10) For example, a single 800-plex SRM assay (e.g., 400 unlabeled and heavy-labeled peptide pairs and 2400 transitions with retention time scheduling) using ultrahigh-performance liquid chromatography (UHPLC) has been developed to quantify proteins in plasma.(11) Advanced labeling techniques utilizing in vitro proteome-assisted MRM for protein absolute quantification (iMPAQT) demonstrated the capability of SRM in genome-wide protein quantification of over 18?000 human proteins.(12) Moreover, the scan speed of QQQ instrumentation has been greatly improved in recent releases of commercial instrumentation. The newly developed TSQ Altis (released in 2017) can scan more than 600 transitions per second, which is 6 times more than a traditional QQQ scan speed of 100 transitions per second. The breadth of measurement enabled by these technological improvements to QQQ mass spectrometry has increased the feasibility and popularity of large scale targeted proteomics studies,(13) a major application of which will be in clinical studies in which up to hundreds of protein candidates need to be quantified in hundreds of clinical specimens.(14) Quantitative accuracy is a primary motivating factor for utilizing a targeted proteomics protocol. The precise and reproducible absolute quantification produced by SRM assays is essential to many clinical and laboratory experiments.(15,16) Because the abundance of an endogenous peptide is calculated from the measurement of the spiked-in reference standard, it is essential to assess the data quality of these references.(17) In early applications of targeted proteomics, when instrument speed greatly limited the number of transitions that could be monitored, much of this quality assessment was done manually. However, recent improvements in instrument performance and experimental design have enabled a dramatic increase in the number of target peptides and associated SRM transitions, which makes manual quality assessment an untenable and laborious task. A variety of computational tools assist in SRM experiment design and data analysis. The first task in creating an SRM experiment is the choice of proteins and representative peptides to monitor. Achieving a reliable protein abundance requires appropriately choosing peptides that have a strong signal and are free from interferences in the biological matrix. Numerous computational tools exist to facilitate assay design by identifying peptides and refining SRM transitions.(18-21) To help share these assays and eliminate time spent designing the same transitions at multiple institutions, community portals have begun to host well-designed and vetted assays.(22-24) Analyzing the experimental data requires significant computational effort to align files across replicates and experimental conditions, pick peaks and produce quantitative values, normalize data and perform statistical tests, etc.(25-27)

Gibbons, Bryson C.↗

Indirect, dual-media, phase changing material modular thermal energy storage system

Design, validate at prototype level, and then demonstrate a full size, 800 MWht Thermal Energy Storage (TES) system based on Phase Changing Material (PCM) TES modules with round trip efficiency in excess of 93%. The PCM TES module would be the building block of a TES system which can be deployed at costs inline with the DOE benchmark of 2020. The development of a reliable, unsophisticated, modular, and scalable TES system designed to be massmanufactured utilizing advanced automated fabrication and assembly processes and field installed in the most cost-effective configuration could facilitate the attainment of a Levelized Cost of Energy (LCOE) of $.07/kWh by 2015. It was believed that the DOE targets can be attained by finding the best combinationTES module size, its optimal integration in the power cycle, and readily available PCM. Work under this project ultimately focused on the development and performance evaluation of a 100kWht prototype heat exchanger. The design utilizes a commercially available heat exchanger product to create a unique latent heat PCM storage module. The novel ideal associated with this technology is the inclusion of an agitation mechanism that is activated during the discharge process to improve heat transfer. The prototype unit did not meet the performance goals estimated through modeling, nor did the estimated costs of the system fall in line with the goals established by DOE.

14 SOLAR ENERGY↗

DOE SunShot (FY15 Final Technical Report)

Sandia National Laboratories (Sandia) manages four of the five PV Regional Test Centers (RTCs). This report reviews accomplishments made by the four Sandia-managed RTCs during FY2015 (October 1, 2014 to September 30, 2015) as well as some programmatic improvements that apply to all five sites. The report is structured by Site first then by Partner within each site followed by the Current and Potential Partner summary table, the New Business Process, and finally the Plan for FY16 and beyond. Since no official SOPO was ever agreed to for FY15, this report does not include reporting on specific milestones and go/no-go decisions. The RTCs validate new solar technologies and system configurations, demonstrating performance and reliability under field conditions over time. There are five sites representing a range of climate conditions (NREL manages the Colorado site). The RTCs provide technical assistance to solar companies in the US. This program has shifted its focus, along with the industry, from validation of large systems to more targeted studies of small systems designed to compare sub-arrays of different module technologies. In addition, the RTCs are actively seeking partners from both module manufacturers and balance-of-systems producers.

14 SOLAR ENERGY↗

Enhanced Accident-Tolerant Fuel Performance and Reliability for Aggressive iPWR/SMR Operation

This project will develop a process that evaluates the whole-core operational and safety performance of a reactor-and-fuel combination by integrating core-wide three-dimensional neutronics with Moose/Bison and Peregrine multi-physics fuel performance assessments using explicit time and space dependent fuel rod operational power histories generated in the whole-core analysis. Demonstration of the process will target large contemporary PWRs with traditional UO2 fuel and Zircaloy cladding to establish a baseline analysis, while the innovative application of this project will extend the developed process to evaluate operational and safety performance, via reactor physics and fuel performance analyses, of key emerging/leading concepts of enhanced Accident Tolerant Fuels (ATFs) within increasingly aggressive operational scenarios such as loadfollow maneuvers in PWRs and long-cycle rodded and unborated operation in small modular reactors (SMRs). The ATFs to be considered include standard UO2 fuel pellets cladded with advanced iron-based alloys (FeCrAl) as well as particle-based Fully Ceramic Microencapsulated (FCM) fuels with FeCrAl or Zircaloy cladding, but the process being developed and demonstrated could ultimately be applied to any candidate ATF concept in a light water reactor. In fact, given that ATF R&D priorities are in a dynamic state, the scope related to ATFs will be targeted for the second half of this three-year project so to provide some opportunity to strengthen the programmatic alignment of this project with the DOE Fuels Campaign, by identifying the most promising and relevant ATFs at that time for further evaluation, while the early part of the project will focus upon fine-tuning the process herein developed and upon generating the baseline analyses against which a larger scope of ATF concepts can be compared.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Systematic Uncertainties and Cross-Checks for the NOvA Joint $\nu_\mu$+$\nu_e$ Analysis

The physics goals of NOvA are the constraints of neutrino oscillation parameters such as the octant of $\theta_{23}$, $\delta_{\rm{CP}}$, and the neutrino mass hierarchy via a joint fit to $\nu_{\mu}$ and $\nu_{e}$ oscillation spectrum. We do this by propagating $\nu_{\mu}$ from the world's most intense neutrino beam at Fermilab, over a baseline of 810 km to northern Minnesota, USA, and measure the $\nu_{\mu}$ to $\nu_{e}$ oscillation probability. NOvA announced its latest oscillation results, based on 8.85$\times10^{20}$ (6.9$\times10^{20}$) protons on target neutrino (antineutrino) data. Preliminary results for the allowed values of oscillation parameters are: $\Delta m^2_{32}=2.51^{+0.12}_{-0.08}\times 10^{-3} \mathrm{eV}^2$, $\mathrm{sin}^2\theta_{23} = 0.58 \pm 0.03$ (upper octant), and $\delta_{\rm{CP}}=0.17\pi$ with preference to the normal hierarchy. Reliable constraints on these oscillation parameters require a rigorous treatment of systematic uncertainties and thorough cross-checks. In this paper, we present an overview of the treatment of systematic uncertainties as well as cross-checks using muon removed simulations and cosmic muon bremsstrahlung showers.

Gandrajula, Reddy Pratap↗

Assessment of surface and bulk-dominated methodologies to measure critical resolved shear stresses in hexagonal materials

We present that crystallographic slip in hexagonal metals involves a number of geometrically distinct slip families characterized by their slip direction and slip plane (basal, prismatic, and pyramidal). Owing to the low symmetry of hexagonal lattices, each of these slip families only have a few symmetrically equivalent slip systems (family members). Furthermore, different slip families become active at different resolved shear stress, i.e., they have different critical resolved shear stress values (CRSS). The plastic anisotropy of hexagonal materials makes the numerical prediction of their plastic behavior challenging and depends critically on the knowledge of CRSS values. The present contribution assesses the reliability of three proposed methods (with additional variations) to quantify CRSS values of the different hexagonal slip families. Those methods (a to c) rely on: (a) the statistics of observed surface slip traces in a (slightly) deformed polycrystal; (b) an iterative adjustment of CRSS values until a simulated single crystal indentation matches the corresponding experiment in terms of load–displacement response and residual surface topography of the indent; (c) in-situ high-energy X-ray diffraction to measure the evolution of resolved stress (from lattice strains) in grains for which single-family slip is probable based upon specific lattice reorientation conditions. Virtual experiments are performed on synthetic microstructures such that the (extracted) CRSS values resulting from simulating the different methodologies can be rigorously compared against the (target) CRSS values that are installed in the phenomenological constitutive material description used in the simulations. The resulting CRSS values of methods (a) exhibit a strong dependence on, and deterioration with, decreasing level of slip trace observability, which is an uncertain quantity in experimental measurements. For the inverse indentation method (b), the predicted CRSS values are within 8 % of their reference CRSS values for the two investigated cases. Lastly, the high-energy X-ray diffraction method (c) most reliably determines CRSS values for basal and prism slip, but lacks a strict grain selection criterion to assess pyramidal slip.

36 MATERIALS SCIENCE↗

Comparison of 3 different postimplant dosimetry methods following permanent {sup 125}I prostate seed brachytherapy

Postimplant dosimetry (PID) after Iodine-125 ({sup 125}I) implant of the prostate should offer a reliable qualitative assessment. So far, there is no consensus regarding the optimum PID method, though the latest literature is in favor of magnetic resonance imaging (MRI). This study aims to simultaneously compare 3 PID techniques: (1) MRI-computed tomography (CT) fusion; (2) ultrasound (US)-CT fusion; and (3) manual target delineation on CT. The study comprised 10 patients with prostate cancer. CT/MR scans with urinary catheters in place for PID were done either on day 0 or day 1 postimplantation. The main parameter evaluated and compared among methods was target D90. The results show that CT-based D90s are lower than US-CT D90s (median difference,−6.85%), whereas MR-CT PID gives higher D90 than US-CT PID (median difference, 4.25%). Manual contouring on CT images tends to overestimate the prostate volume compared with transrectal ultrasound (TRUS) (median difference, 23.33%), whereas on US images the target is overestimated compared with MR-based contouring (median difference, 13.25%). Although there are certain differences among the results given by various PID techniques, the differences are statistically insignificant for this small group of patients. Any dosimetric comparison between 2 PID techniques should also account for the limitations of each technique, to allow for an accurate quantification of data. Given that PID after permanent radioactive seed implant is mandatory for quality assurance, any imaging method–based PID (MR-CT, US-CT, and CT) available in a radiotherapy department can be indicative of the quality of the procedure.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Note to Reviewers Suggesting Post-reaction Catalyst Characterization: Know What You’re Asking For

Here, we highlight examples of post-reaction characterization in thermo- and electrocatalysis to present the challenges in obtaining reliable data to answer specific questions about the true identity of the active site and/or catalyst deactivation/degradation. We use this editorial to suggest to reviewers that, when formulating comments to authors that involve materials characterization after reaction testing, they should consider what specific, meaningful information can be attained or what targeted question can be answered that adds value to the individual paper and to the field in general, and how to reasonably obtain that data. In contrast, reviewers should avoid vague, open-ended comments that suggest unguided post-reaction characterization that would not add significant value to the report and, similarly, avoid comments that are substantial enough that they could form the basis of an entirely separate report.

36 MATERIALS SCIENCE↗

Plug-and-play polymer microfluidic chips for hydrated, room temperature, fixed-target serial crystallography

The practice of serial X-ray crystallography (SX) depends on efficient, continuous delivery of hydrated protein crystals while minimizing background scattering. Of the two major types of sample delivery devices, fixed-target devices offer several advantages over widely adopted jet injectors, including: lower sample consumption, clog-free delivery, and the ability to control on-chip crystal density to improve hit rates. In this study we present our development of versatile, inexpensive, and robust polymer microfluidic chips for routine and reliable room temperature serial measurements at both synchrotrons and X-ray free electron lasers (XFELs). Our design includes highly X-ray-transparent enclosing thin film layers tuned to minimize scatter background, adaptable sample flow layers tuned to match crystal size, and a large sample area compatible with both raster scanning and rotation based serial data collection. The optically transparent chips can be used both for in situ protein crystallization (to eliminate crystal handling) or crystal slurry loading, with prepared samples stable for weeks in a humidified environment and for several hours in ambient conditions. Serial oscillation crystallography, using a multi-crystal rotational data collection approach, at a microfocus synchrotron beamline (SSRL, beamline 12-1) was used to benchmark the performance of the chips. Furthermore, high-resolution structures (1.3–2.7 Å) were collected from five different proteins – hen egg white lysozyme, thaumatin, bovine liver catalase, concanavalin-A (type VI), and SARS-CoV-2 nonstructural protein NSP5. Overall, our modular fabrication approach enables precise control over the cross-section of materials in the X-ray beam path and facilitates chip adaption to different sample and beamline requirements for user-friendly, straightforward diffraction measurements at room temperature.

59 BASIC BIOLOGICAL SCIENCES↗

Target Normal Sheath Acceleration at ultrahigh intensities: a theoretical parametric investigation

Ions can be effectively accelerated during the interaction of an ultra-intense ultra-short laser pulse irradiating a thin solid target via the so-called Target Normal Sheath Acceleration (TNSA) mechanism. One of the crucial issues at this stage of the research is how to predict the properties of the accelerated ions, both from a fundamental point of view and in the light of foreseen applications. Thus, it is desirable to have a simple but reliable description, to be used to extrapolate current results to regimes likely to be reached in the near future, thanks to developments in laser technology. In this work we theoretically investigated the maximum ion energy achieved in TNSA as a function of laser properties, with special focus to the ranges I{sub L}(pulse intensity)10{sup 20}-10{sup 22} W/cm{sup 2} and E{sub L}(pulse energy) 1-30 J, which appear to be the most interesting for future facilities. Particular attention will be devoted to elucidate the effective dependence of the maximum ion energy on the laser intensity for different combinations of laser parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TH-CD-BRA-02: 3D Remote Dosimetry for MRI-Guided Radiation Therapy: A Hybrid Approach

Purpose: To validate the dosimetric accuracy of a commercially available MR-IGRT system using a combination of 3D dosimetry measurements (with PRESAGE(R) radiochromic plastic and optical-CT readout) and an in-house developed GPU-accelerated PENELOPE Monte-Carlo dose calculation system. Methods: {sup 60}Co IMRT subject to a 0.35T lateral magnetic field has recently been commissioned in our institution following AAPM’s TG-119 recommendations. We performed PRESAGE(R) sensitivity studies in 4ml cuvettes to verify linearity, MR-compatibility, and energy-independence. Using 10cm diameter PRESAGE(R), we delivered an open calibration field to examine the percent depth dose and a symmetrical 3-field plan with three adjacent regions of varying dose to determine uniformity within the dosimeter under a magnetic field. After initial testing, TG-119 plans were created in the TPS and then delivered to 14.5cm 2kg PRESAGE(R) dosimeters. Dose readout was performed via optical-CT at a second institution specializing in remote 3D dosimetry. Absolute dose was measured using an IBA CC01 ion chamber and the institution standard patient-specific QA methods were used to validate plan delivery. Calculated TG-119 plans were then compared with an independent Monte Carlo dose calculation (gPENELOPE). Results: PRESAGE(R) responds linearly (R{sup 2}=0.9996) to {sup 60}Co irradiation, in the presence of a 0.35T magnetic field, with a sensitivity of 0.0305(±0.003)cm{sup −1}Gy{sup −1}, within 1% of a 6MV non-MR linac irradiation (R{sup 2}=0.9991) with a sensitivity of 0.0302(±0.003)cm{sup −1}Gy{sup −1}. Analysis of TG-119 clinical plans using 3D-gamma (3%/3mm, 10% threshold) give passing rates of: HN 99.1%, prostate 98.0%, C-shape 90.8%, and multi-target 98.5%. The TPS agreed with gPENELOPE with a mean gamma passing rate of 98.4±1.5% (2%/2mm) with the z-score distributions following a standard normal distribution. Conclusion: We demonstrate for the first time that 3D remote dosimetry using both experimental and computational methods is a feasible and reliable approach to commissioning MR-IMRT, which is particularly useful for less specialized clinics in adopting this new treatment modality.

60 APPLIED LIFE SCIENCES↗

Integrating Variable Renewable Energy into the Grid: Key Issues, Greening the Grid

To foster sustainable, low-emission development, many countries are establishing ambitious renewable energy targets for their electricity supply. Because solar and wind tend to be more variable and uncertain than conventional sources, meeting these targets will involve changes to power system planning and operations. Grid integration is the practice of developing efficient ways to deliver variable renewable energy (VRE) to the grid. Good integration methods maximize the cost-effectiveness of incorporating VRE into the power system while maintaining or increasing system stability and reliability. When considering grid integration, policy makers, regulators, and system operators consider a variety of issues, which can be organized into four broad topics: New Renewable Energy Generation, New Transmission, Increased System Flexibility, Planning for a High RE Future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrating Variable Renewable Energy into the Grid: Key Issues, Greening the Grid (Spanish Version)

This is the Spanish version of 'Greening the Grid - Integrating Variable Renewable Energy into the Grid: Key Issues'. To foster sustainable, low-emission development, many countries are establishing ambitious renewable energy targets for their electricity supply. Because solar and wind tend to be more variable and uncertain than conventional sources, meeting these targets will involve changes to power system planning and operations. Grid integration is the practice of developing efficient ways to deliver variable renewable energy (VRE) to the grid. Good integration methods maximize the cost-effectiveness of incorporating VRE into the power system while maintaining or increasing system stability and reliability. When considering grid integration, policy makers, regulators, and system operators consider a variety of issues, which can be organized into four broad topics: New Renewable Energy Generation, New Transmission, Increased System Flexibility, and Planning for a High RE Future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrating Variable Renewable Energy - Russia

To foster sustainable, low-emission development, many countries are establishing ambitious renewable energy targets for their electricity supply. Because solar and wind tend to be more variable and uncertain than conventional sources, meeting these targets will involve changes to power system planning and operations. Grid integration is the practice of developing efficient ways to deliver variable renewable energy (VRE) to the grid. Good integration methods maximize the cost-effectiveness of incorporating VRE into the power system while maintaining or increasing system stability and reliability. When considering grid integration, policy makers, regulators, and system operators consider a variety of issues, which can be organized into four broad topics: New Renewable Energy Generation, New Transmission, Increased System Flexibility, Planning for a High RE Future. This is a Russian-language translation of Integrating Variable Renewable Energy into the Grid: Key Issues, Greening the Grid, originally published in English in May 2015.

24 POWER TRANSMISSION AND DISTRIBUTION↗