Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAMPLING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

rHealth One Demonstration Aboard ISS: A Microfluidic Bioanalyzer Based on Sheath/Hydrodynamic Focusing Flow Cytometry

The Exploration Medical Capability (ExMC) element aims to provide astronauts with the means for their own health monitoring, diagnosis, and treatment during exploration missions. As space flight ventures further from earth, the need for autonomous medical care increases under greater constraints on size, mass, and resources. One pillar for diagnosis that crew would be separated from is laboratory analysis. Even now on ISS, blood samples must be collected and returned to earth for testing. In response, ExMC is assessing how assays for hematology, bone health, radiation exposure etc. could be addressed through commercial-off-the-shelf (COTS) and Small Business Innovation Research (SBIR) funded bioanalyzers that are miniaturizing lab technology. Since missions will reach distances where there are no timely replacements, validation on the International Space Station (ISS) is a necessary part of that assessment. In partnership with NASA Johnson Space Center (JSC) Immunology Lab and the Research Operations and Integration (ROI) element, ExMC conducted a technology demonstration on ISS of the rHEALTH ONE, a flow cytometry based bioanalyzer, to assess future devices based on this design. In flow cytometry, there are predominantly three ways to focus the cells (or particles) into a single file stream: hydrodynamic focusing, microcapillary, and acoustic focusing. The rHEALTH ONE utilizes the commercial standard, sheath-based hydrodynamic focusing. rHEALTH itself represents both a company and a suite of medical tools NASA has funded through SBIR grants towards the development of a promising diagnosis instrument for exploration missions. rHEALTH ONE is the interim version of the technology, functional as a benchtop analyzer and test bed for the next generation of rHEALTH in development. Several modifications were made to the rHEALTH ONE analyzer for operation in microgravity. For function, fluid management was key. A sheath-based analyzer uses sheath fluid to flow the sample, cleaning fluid to prevent biological contamination, and a reservoir to collect the liquid waste. The rHEALTH ONE analyzer uses bottles dependent on gravity to separate the air and liquid pathways and keep the liquids contained. It uses only 1 psig of air pressure to directly push the liquid through the device, requiring little-to-no resistance at inlet and outlet. A microtubing assembly with self-sealing luer connectors was designed – featuring 0.014 mm thick durable medical balloons to hold water inside the supply bottles – to create safe containment and easy access for the crew while maintaining the analyzer’s function. For safety, copper tape was added to the interior of the plastic housing to reduce electromagnetic interference, fluid and electrical connections were secured against vibration and leaks, and gaps were further sealed to ensure containment of the optical block and lasers. Water as the sheath and cleaning fluid and TOX 0 samples were used to reduce the biohazard risk to the crew. In May 2022, European Space Agency astronaut Samantha Cristoforetti demonstrated the rHEALTH ONE aboard ISS for its sample loading, flow cytometry, and data collection capability in microgravity. The JSC Immunology Lab provided flow cytometry expertise, designed the sample test protocol, and manufactured and benchmarked the flight samples on a ‘gold-standard’ flow cytometer. The analyzer was primed with water, purged of air, and four calibration solutions of polystyrene microparticles were tested to characterize its performance. Tightly controlled procedures and excellent execution prevented air bubble interference during air/water separation, fluid transfer, sample mixing and loading. Data showed a slight increase in signal noise on 3 of 5 channels and an anomaly of fluorophores migrating in one sample (confirmed by JSC post-flight). Flight results correctly detected the change in sample, matched the analyzer’s ground performance, and were consistent with the gold-standard’s ground results. Although areas were noted for improvement, these outcomes signified complete mission success.

R. S. Miller↗

Culture-Independent Fungal Profiling for the International Space Station using Nanopore Sequencing: Method Development

Microbial monitoring of the International Space Station (ISS) environment is a crew health requirement that encompasses both bacterial and fungal identification. To achieve this currently, culture-based methods are used for sample collection, and these samples must be returned to the laboratory for analysis. The use of culture and the need for sample return to Earth results in a bias toward culturable organisms and causes a significant delay between sample collection and delivery of final data (weeks to months), respectively. Recently, advancements in molecular technology have aided a broad range of applications, including medical, industrial, and basic sciences. Additionally, increases in portability and ease-of-use of molecular platforms have provided point-of-use capabilities demonstrated by the miniPCR thermal cycler (miniPCR bio) and the MinION sequencer (Oxford Nanopore Technologies). Together, these devices have been applied to, and validated for, the identification of bacteria onboard the ISS. Building on this work, we have developed a spaceflight-compatible fungal workflow. Molecular-based fungal analysis is complicated by low biomass, difficult-to-lyse spores, debate regarding the region for taxonomic assignment, and the lack of bioinformatic pipelines and reference databases. To overcome these difficulties, primers yielding an ~ 2 Kb amplicon were validated against a wide range of ISS fungal isolates. The current spaceflight library preparation was substantially optimized, a bioinformatic pipeline was created, and refinements to the UNITE database were implemented. To compare this optimized method to the current culture-based standard, 30 sample sets (60 total swabs, two swabs held in tandem) were evaluated. Parallel fungal profiles were obtained between the two methods, with the culture-independent method revealing increased diversity. The addition of this method to the already established bacterial process fulfills the crew health identification requirement. Moreover, the implementation of this method onboard ISS will enhance our understanding of its unique fungal microbiome.

Hang N. Nguyen↗

Tidal distortions in pairs of early-type galaxies

The authors are conducting an imaging survey of pairs of elliptical galaxies which has already produced interesting results. Some pairs present a common pattern of distortion interpreted in terms of tidal effects (Davoust and Prugniel, 1988; Prugniel et al., 1989). Other examples drawn from the literature (Borne and Hoessel, 1988; Colina and Perez-Fournon, 1990) share the same morphology. New cases and lists of the characteristics of 24 such systems. The authors' pairs are drawn from a sample of binary and multiple galaxies which has in turn been extracted from the CGCG, UGC (Nilson, 1973) and VV (Vorontsov-Velyaminov, 1959) catalogues. This sample includes that of Karachentsev (1972). It contains 1800 pairs, among which 700 are S - S or mixed morphology pairs. The authors are working on the remainder to produce a sample of close physical pairs of elliptical galaxies (they also include bulge dominated SO's since the morphological discrimination from ellipticals is often ambiguous, in particular for interacting galaxies). One of the interests of this work is to provide a sample selected on purely optical criteria, at variance with other works (e.g., Valentijn and Casertano, 1988). This will allow statistical studies of non-optical properties of these pairs (in particular radio emission). The authors have so far obtained charge-coupled device (CCD) images of 125 pairs with a 2m telescope and velocities' differences of 78 pairs were obtained using the 1.93 meter telescope of Observatoire de Haute Provence and from the literature. One is an optical pair (VV 190). Eighteen of our pairs present the morphological effect described in Davoust and Prugniel (1988): the external parts of each member are stretched in opposite senses in a direction rougly perpendicular to the pair axis. The proportion of 15 plus or minus 4 percent distorted pairs confirms previous estimates. Except for a few cases involving flattened galaxies with nearly aligned major axes which deserve careful detailed analysis (Prugniel, 1989), the apparent distortions do correspond to physical distortions. We have searched the literature for isophote maps showing this effect. In the survey of radio galaxies by Colina and Perez-Fournon (1990), 7 out of 20 pairs show this characteristic distortion.

Prugniel, Philippe↗

Low power arcjet system spacecraft impacts

Potential plume contamination of spacecraft surfaces was investigated by positioning spacecraft material samples relative to an arcjet thruster. Samples in the simulated solar array region were exposed to the cold gas arcjet plume for 40 hrs to address concerns about contamination by backstreaming diffusion pump oil. Except for one sample, no significant changes were measured in absorptance and emittance within experimental error. Concerns about surface property degradation due to electrostatic discharges led to the investigation of the discharge phenomenon of charged samples during arcjet ignition. Short duration exposure of charged samples demonstrated that potential differences are consistently and completely eliminated within the first second of exposure to a weakly ionized plume. The spark discharge mechanism was not the discharge phenomenon. The results suggest that the arcjet could act as a charge control device on spacecraft.

Pencil, Eric J.↗

Flux-focusing eddy current probe and method for flaw detection

A flux-focusing electromagnetic sensor which uses a ferromagnetic flux-focusing lens simplifies inspections and increases detectability of fatigue cracks and material loss in high conductivity material is presented. The unique feature of the device is the ferrous shield isolating a high-turn pick-up coil from an excitation coil. The use of the magnetic shield is shown to produce a null voltage output across the receiving coil in the presence of an unflawed sample. A redistribution of the current flow in the sample caused by the presence of flaws, however, eliminates the shielding condition and a large output voltage is produced, yielding a clear unambiguous flaw signal. The maximum sensor output is obtained when positioned symmetrically above the crack. Hence, by obtaining the position of the maximum sensor output, it is possible to track the fault and locate the area surrounding its tip. The accuracy of tip location is enhanced by two unique features of the sensor; a very high signal-to-noise ratio of the probe's output which results in an extremely smooth signal peak across the fault, and a rapidly decaying sensor output outside a small area surrounding the crack tip which enables the region for searching to be clearly defined. Under low frequency operation, material thinning due to corrosion damage causes an incomplete shielding of the pick-up coil. The low frequency output voltage of the probe is therefore a direct indicator of the thickness of the test sample.

Simpson, John W.↗

Flux-focusing eddy current probe and rotating probe method for flaw detection

A flux-focusing electromagnetic sensor which uses a ferromagnetic flux-focusing lens simplifies inspections and increases detectability of fatigue cracks about circular fasteners and other circular inhomogeneities in high conductivity material. The unique feature of the device is the ferrous shield isolating a high-turn pick-up coil from an excitation coil. The use of the magnetic shield is shown to produce a null voltage output across the receiving coil in the presence of an unflawed sample. A redistribution of the current flow in the sample caused by the presence of flaws, however, eliminates the shielding condition and a large output voltage is produced, yielding a clear unambiguous flaw signal. By rotating the probe in a path around a circular fastener such as a rivet while maintaining a constant distance between the probe and the center of a rivet, the signal due to current flow about the rivet can be held constant. Any further changes in the current distribution, such as due to a fatigue crack at the rivet joint, can be detected as an increase in the output voltage above that due to the flow about the rivet head.

Wincheski, Buzz A.↗

Imaging Spectrometry-Concepts and System Tradeoffs

The concept of imaging spectrometry is finding broad application in scientific instrumentation for earth-based, airborne, and space applications. An imaging spectrometer is characterized by the combination of imaging with complete sampling in the spectral domain. In so doing, material identification can be accomplished and displayed in conjunction with the conventional recognizable image. An image spectrometer incorporates a wide variety of techniques, including focal plane arrays, imaging and spectrometer optics, and spectral dispersing devices. The design of a successful system involves a complex set of tradeoffs incorporating the properties and limitations of the various technologies. For applications in the infrared, additional technologies such as focal plane cooling are required, and the other technologies present more limitations and constraints.

Herring, M.↗

Rotating flux-focusing eddy current probe for flaw detection

A flux-focusing electromagnetic sensor which uses a ferromagnetic flux-focusing lens simplifies inspections and increases detectability of fatigue cracks about circular fasteners and other circular inhomogeneities in high conductivity material. The unique feature of the device is the ferrous shield isolating a high-turn pick-up coil from an excitation coil, The use of the magnetic shield is shown to produce a null voltage output across the receiving coil in the presence of an unflawed sample. A redistribution of the current flow in the sample caused by the presence of flaws, however, eliminates the shielding condition and a large output voltage is produced, yielding a clear unambiguous flaw signal. By rotating the probe in a path around a circular fastener such as a rivet while maintaining a constant distance between the probe and the center of a rivet, the signal due to current flow about the rivet can be held constant. Any further changes in the current distribution, such as due to a fatigue crack at the rivet joint, can be detected as an increase in the output voltage above that due to the flow about the rivet head.

Wincheski, Russell A.↗

Flux focusing eddy current probe

A flux-focusing electromagnetic sensor which uses a ferromagnetic flux-focusing lens simplifies inspections and increases detectability of fatigue cracks and material loss in high conductivity material. The unique feature of the device is the ferrous shield isolating a high-turn pick-up coil from an excitation coil. The use of the magnetic shield is shown to produce a null voltage output across the receiving coil in the presence of an unflawed sample. A redistribution of the current flow in the sample caused by the presence of flaws, however, eliminates the shielding condition and a large output voltage is produced, yielding a clear unambiguous flaw signal. The maximum sensor output is obtained when positioned symmetrically above the crack. Hence, by obtaining the position of the maximum sensor output, it is possible to track the fault and locate the area surrounding its tip. The accuracy of tip location is enhanced by two unique features of the sensor; a very high signal-to-noise ratio of the probe's output which results in an extremely smooth signal peak across the fault, and a rapidly decaying sensor output outside a small area surrounding the crack tip which enables the region for searching to be clearly defined. Under low frequency operation, material thinning due to corrosion damage causes an incomplete shielding of the pick-up coil. The low frequency output voltage of the probe is therefore a direct indicator of the thickness of the test sample.

Simpson, John W.↗

Image sensor with high dynamic range linear output

Designs and operational methods to increase the dynamic range of image sensors and APS devices in particular by achieving more than one integration times for each pixel thereof. An APS system with more than one column-parallel signal chains for readout are described for maintaining a high frame rate in readout. Each active pixel is sampled for multiple times during a single frame readout, thus resulting in multiple integration times. The operation methods can also be used to obtain multiple integration times for each pixel with an APS design having a single column-parallel signal chain for readout. Furthermore, analog-to-digital conversion of high speed and high resolution can be implemented.

Yadid-Pecht, Orly↗

Analysis of Screen Channel LAD Bubble Point Tests in Liquid Oxygen at Elevated Temperature

The purpose of this paper is to examine the key parameters that affect the bubble point pressure for screen channel Liquid Acquisition Devices in cryogenic liquid oxygen at elevated pressures and temperatures. An in depth analysis of the effect of varying temperature, pressure, and pressurization gas on bubble point is presented. Testing of a 200 x 1400 and 325 x 2300 Dutch Twill screen sample was conducted in the Cryogenics Components Lab 7 facility at the NASA Glenn Research Center in Cleveland, Ohio. Test conditions ranged from 92 to 130K and 0.138 - 1.79 MPa. Bubble point is shown to be a strong function of temperature with a secondary dependence on pressure. The pressure dependence is believed to be a function of the amount of evaporation and condensation occurring at the screen. Good agreement exists between data and theory for normally saturated liquid but the model generally under predicts the bubble point in subcooled liquid. Better correlation with the data is obtained by using the liquid temperature at the screen to determine surface tension of the fluid, as opposed to the bulk liquid temperature.

Hartwig, Jason↗

Component Characterization of an eVTOL Reference Model for Crashworthiness Studies

Researchers at the National Aeronautics and Space Administration (NASA) Langley Research Center (LaRC) have conducted a series of structural component and seat level tests to improve finite element model (FEM) characterization of a representative vertical take-off and landing (eVTOL) test article developed by NASA. A full-scale dynamic test was conducted on the representative eVTOL test article in November of 2022. The test article represented a high wing, six passenger eVTOL design concept and is referred to as the lift plus cruise (LPC) test article. The full-scale test identified limitations in the analytical models used to predict aircraft structural response, in particular the composite material models did not effectively capture brittle failure of the structure which were measured during dynamic loading. To better understand the mechanism behind the composite material failure mechanisms observed and to improve the FEM, intact sample specimens of the composite airframe structure were recovered from the test article post-test and used in material characterization testing. In addition, the seat configurations used in the LPC test article were further studied using isolated seat and anthropomorphic test device (ATD) drop tower testing. Dynamic compression tests and three-point bend tests, conducted at varied impact speeds, were performed on the recovered frame section specimens. Additional testing was conducted to characterize the material properties of the forming foam, which remained in the frames after fabrication. These tests were used to improve characterization of the damage and failure parameters of the composite material model used in the FE model of the LPC test article. Seat level tests were conducted on the seats used in the LPC test article using acceleration pulses inclusive of current general aviation and rotorcraft certification load levels as well as conditions representative of those measured at the seat base during the LPC test. The structural material models and seat environment models of the LPC test article FEM were calibrated using the generated component test data. The updates made to these models were then integrated into the LPC FEM and simulated in the full-scale test condition. Results demonstrated the effectiveness of component testing to improve predictive capability of composite aerospace structural models within the crash and dynamic loading environments. Demonstration of the LPC FEM response across an accumulation of coupon, component, seat environment, and full-scale test levels provides confidence in the predictive capability of this model for future use in the study of occupant safety within eVTOL relevant crash environments.

Craswhorthiness↗

Component Characterization of an eVTOL Reference Model for Crashworthiness Studies

Researchers at the National Aeronautics and Space Administration (NASA) Langley Research Center (LaRC) have conducted a series of structural component and seat level tests to improve finite element model (FEM) characterization of a representative vertical take-off and landing (eVTOL) test article developed by NASA. A full-scale dynamic test was conducted on the representative eVTOL test article in November of 2022. The test article represented a high wing, six passenger eVTOL design concept and is referred to as the lift plus cruise (LPC) test article. The full-scale test identified limitations in the analytical models used to predict aircraft structural response, in particular the composite material models did not effectively capture brittle failure of the structure which were measured during dynamic loading. To better understand the mechanism behind the composite material failure mechanisms observed and to improve the FEM, intact sample specimens of the composite airframe structure were recovered from the test article post-test and used in material characterization testing. In addition, the seat configurations used in the LPC test article were further studied using isolated seat and anthropomorphic test device (ATD) drop tower testing. Dynamic compression tests and three-point bend tests, conducted at varied impact speeds, were performed on the recovered frame section specimens. Additional testing was conducted to characterize the material properties of the forming foam, which remained in the frames after fabrication. These tests were used to improve characterization of the damage and failure parameters of the composite material model used in the FE model of the LPC test article. Seat level tests were conducted on the seats used in the LPC test article using acceleration pulses inclusive of current general aviation and rotorcraft certification load levels as well as conditions representative of those measured at the seat base during the LPC test. The structural material models and seat environment models of the LPC test article FEM were calibrated using the generated component test data. The updates made to these models were then integrated into the LPC FEM and simulated in the full-scale test condition. Results demonstrated the effectiveness of component testing to improve predictive capability of composite aerospace structural models within the crash and dynamic loading environments. Demonstration of the LPC FEM response across an accumulation of coupon, component, seat environment, and full-scale test levels provides confidence in the predictive capability of this model for future use in the study of occupant safety within eVTOL relevant crash environments.

Craswhorthiness↗

Gas-grain simulation experiment module conceptual design and gas-grain simulation facility breadboard development

This report delineates the Option portion of the Phase A Gas-Grain Simulation Facility study. The conceptual design of a Gas-Grain Simulation Experiment Module (GGSEM) for Space Shuttle Middeck is discussed. In addition, a laboratory breadboard was developed during this study to develop a key function for the GGSEM and the GGSF, specifically, a solid particle cloud generating device. The breadboard design and test results are discussed and recommendations for further studies are included. The GGSEM is intended to fly on board a low earth orbit (LEO), manned platform. It will be used to perform a subset of the experiments planned for the GGSF for Space Station Freedom, as it can partially accommodate a number of the science experiments. The outcome of the experiments performed will provide an increased understanding of the operational requirements for the GGSF. The GGSEM will also act as a platform to accomplish technology development and proof-of-principle experiments for GGSF hardware, and to verify concepts and designs of hardware for GGSF. The GGSEM will allow assembled subsystems to be tested to verify facility level operation. The technology development that can be accommodated by the GGSEM includes: GGSF sample generation techniques, GGSF on-line diagnostics techniques, sample collection techniques, performance of various types of sensors for environmental monitoring, and some off-line diagnostics. Advantages and disadvantages of several LEO platforms available for GGSEM applications are identified and discussed. Several of the anticipated GGSF experiments require the deagglomeration and dispensing of dry solid particles into an experiment chamber. During the GGSF Phase A study, various techniques and devices available for the solid particle aerosol generator were reviewed. As a result of this review, solid particle deagglomeration and dispensing were identified as key undeveloped technologies in the GGSF design. A laboratory breadboard version of a solid particle generation system was developed and characterization tests performed. The breadboard hardware emulates the functions of the GGSF solid particle cloud generator in a ground laboratory environment, but with some modifications, can be used on other platforms.

Zamel, James M.↗

Characterization of Carbon Dioxide Washout Measurement Techniques in the Mark-III Space Suit

A space suit must provide adequate carbon dioxide (CO2) washout inside the helmet to prevent symptoms of hypercapnia. In the past, an oronasal mask has been used to measure the inspired air of suited subjects to determine a space suit's CO2 washout capability. While sufficient for super-ambient pressure testing of space suits, the oronasal mask fails to meet several human factors and operational criterion needed for future sub-ambient pressure testing (e.g. compatibility with a Valsalva device). This paper describes the evaluation of a nasal cannula as a device for measuring inspired air within a space suit. Eight test subjects were tasked with walking on a treadmill or operating an arm ergometer to achieve target metabolic rates of 1000, 2000, and 3000 British thermal units per hour (BTU/hr), at flow rates of 2, 4, and 6 actual cubic feet per minute (ACFM). Each test configuration was conducted twice, with subjects instructed to breathe either through their nose only, or however they felt comfortable. Test data shows that the nasal cannula provides more statistically consistent data across test subjects than the oronasal mask used in previous tests. The data also shows that inhaling/exhaling through only the nose provides a lower sample variance than a normal breathing style. Nose-only breathing reports better CO2 washout due to several possible reasons, including a decreased respiratory rate, an increased tidal volume, and because nose-only breathing directs all of the exhaled CO2 down and away from the oronasal region. The test subjects in this study provided feedback that the nasal cannula is comfortable and can be used with the Valsalva device.

Meginnis, Ian M.↗

Steady-state probability density function of the phase error for a DPLL with an integrate-and-dump device

The steady-state behavior of a particular type of digital phase-locked loop (DPLL) with an integrate-and-dump circuit following the phase detector is characterized in terms of the probability density function (pdf) of the phase error in the loop. Although the loop is entirely digital from an implementation standpoint, it operates at two extremely different sampling rates. In particular, the combination of a phase detector and an integrate-and-dump circuit operates at a very high rate whereas the loop update rate is very slow by comparison. Because of this dichotomy, the loop can be analyzed by hybrid analog/digital (s/z domain) techniques. The loop is modeled in such a general fashion that previous analyses of the Real-Time Combiner (RTC), Subcarrier Demodulator Assembly (SDA), and Symbol Synchronization Assembly (SSA) fall out as special cases.

Simon, M.↗

Development of chip passivated monolithic complementary MISFET circuits with beam leads

The results are presented of a program to demonstrate the processes for fabricating complementary MISFET beam-leaded circuits, which, potentially, are comparable in quality to available bipolar beam-lead chips that use silicon nitride passivation in conjunction with a platinum-titanium-gold metal system. Materials and techniques, different from the bipolar case, were used in order to be more compatible with the special requirements of fully passivated complementary MISFET devices. Two types of circuits were designed and fabricated, a D-flip-flop and a three-input NOR/NAND gate. Fifty beam-leaded chips of each type were constructed. A quality and reliability assurance program was performed to identify failure mechanisms. Sample tests and inspections (including destructive) were developed to measure the physical characteristics of the circuits.

Ragonese, L. J.↗

Mars Molecular and Isotopic Analysis Research Study

Recently, the Martian atmosphere and surface constituents have become of great interest. The Viking in situ gas chromatograph mass spectrometer experiment contributed greatly to our knowledge of the composition of the Martian atmosphere. However, important questions remain such as the abundance of water on Mars. The Viking experiment employed solid reagents to enhance their carbon measurements. Techniques of chemical conversion using simple solid reagents have advanced considerably in the past 20 years. In this investigation we researched the advancements in techniques to reversibly adsorb and desorb water and focused on the techniques potentially useful for the temperatures and pressures on the Martian surface. During the granting period from June 15, 1998 to August 14, 1998, a literature study of the material appropriate for use in a chemical conversion device and the availability of these materials were undertaken. The focus of this investigation was searching for methods and materials potentially useful in enhancing the measurements of water. Three different methods were considered for the means to extract water from a given gas sample. These methods included adsorption in a desiccant, adsorption on a clean metal surface, and adsorption in a carbon molecular sieve or zeolite. Each method was evaluated with feasibility and reversibility in mind. By far the simplest and perhaps cheapest way to remove water from a gaseous sample is by means of a bulk desiccant. Desiccants are commercially available from many companies including those that supply chemicals. The main feature of a desiccant is its ability to rapidly bind or absorb water from the atmosphere. Calcium chloride, for example, is frequently incorporated into drying tubes by organic chemists when reactions require the absence of water. Other desiccants include sodium hydroxide, calcium hydride, and commercial products such as Drierite, available from Aldrich Chemical. The disadvantage to most desiccants is a direct consequence of what makes them so advantageous. Desiccants rapidly and strongly bind water, often reacting chemically with it. This strong binding makes reversibly desorbing the water from the desiccant very difficult. The third method by which to absorb water from a gas sample involves the use of molecular sieves of other ziolites.

Manning, Heidi L. K.↗