Search NASA⌕ Search

SEARCH · Search NASA

Results for “STORAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Assessment of tank designs for hydrogen storage on heavy duty vehicles using metal hydrides

The objective of this project was to evaluate material-based hydrogen storage solutions as a replacement for high-pressure hydrogen gas or liquid hydrogen on Class 7 or 8 tractor fuel cell electric vehicles. The project focused on low-density main-group hydrides, a well-known class of materials for hydrogen storage. Prior research has considered metal amides as storage materials for light-duty vehicles but not for heavy-duty applications. The project established the basis for further development of storage systems of this type for heavy duty vehicles (HDV). Systems analysis of an HDV storage system comprised of a tank and associated balance of plant (piping, coolant tubes, burner) was performed to determine the usable hydrogen capacity. A composite storage material comprised of a metal hydride mixed with a high thermal-conductivity carbon is predicted to have a usable hydrogen volumetric capacity comparable to or exceeding that of 700 bar pressurized hydrogen gas. The gravimetric capacity of this material is also predicted to be competitive with pressurized gas, particularly if costly carbon fiber composite Type III or Type IV tanks are excluded. The storage system design parameters and material properties served as inputs to a second model that simulates fuel cell operation in conjunction with the storage system during an HDV drive cycle. The results show that sufficient hydrogen pressure can be produced to operate a Class 8 HDV, yielding a range of ~480 miles. These results are particularly relevant for high-impact regions, such as the South Coast Air Quality Management District, for which an economical vehicular hydrogen storage system with minimal impact on cargo capacity could accelerate adoption of heavy-duty fuel cell electric vehicles. An additional benefit is that knowledge generated by this project can assist in development of material-based storage for stationary applications such as microgrids and backup power for data centers.

08 HYDROGEN↗

NORTH DAKOTA CARBONSAFE PHASE III: SITE CHARACTERIZATION AND PERMITTING OF GEOLOGIC STORAGE OF CARBON DIOXIDE

The Energy & Environmental Research Center (EERC), in partnership with Minnkota Power Cooperative Inc. (Minnkota), SLB, and Computer Modelling Group Ltd. (CMG), supported wide-scale deployment of carbon capture and storage (CCS) as part of the U.S. Department of Energy (DOE) National Energy Technology Laboratory Carbon Storage Assurance Facility Enterprise (CarbonSAFE) Initiative Phase III. This phase included the acquisition, analysis, and development of information to fully characterize two storage complexes to demonstrate viable storage resources for commercial volumes of CO2 (defined by DOE as a minimum of 50 million tonnes [MMt] of CO2 within a 30-year period) (National Energy Technology Laboratory, 2024). Phase III also involved the preparation, submission, and approval of North Dakota underground injection control (UIC) Class VI storage facility permits (SFPs)—required precursors to applications for Class VI injection well permits. The presumed viability of commercial-scale CCS, situated adjacent to Minnkota’s Milton R. Young Station (MRYS), is validated by Minnkota’s continued pursuit of Project Tundra—an initiative to build the world’s largest lignite-based CCS project in central North Dakota (www.projecttundrand.com). Project Tundra comprises two scopes of work, Tundra Capture (installation of postcombustion CO2 capture at MRYS) and Tundra SGS (secure geologic storage). The efforts of North Dakota CarbonSAFE Phase III, Site Characterization and Permitting, supported Tundra SGS. Extensive site-specific characterization activities included a successful multimeasurement geophysical approach and drilling a stratigraphic test well (J-ROC 1, subsequently renamed Liberty-1) adjacent to MRYS. Core collection and analyses, downhole testing and fluid sampling, and geophysical logging were performed on J-ROC 1 and on a nearby stratigraphic test well (known as J-LOC 1), which was drilled, cored, and tested under a complementary project funded by the North Dakota Lignite Research Program. The injection tests performed on J-LOC 1 positively impacted the CarbonSAFE project, resulting in fewer proposed injection wells and significant construction, operations, and monitoring cost savings. The characterization data collected and analyses performed were integrated into geologic models, and successive numerical simulations were run to determine CO2 plume extent and subsurface pressure buildup associated with the planned CO2 injection rate of nearly 4 MMt per year. The latter doubles the CarbonSAFE Initiative goal with an estimated 100 MMt of CO2 stored in 20 years. Application of the U.S. Environmental Protection Agency’s (EPA’s) method for estimating the Class VI Rule area of review (AOR) to the overpressurized Broom Creek Formation inspired an alternative method of calculation, called risk-based AOR delineation. This peer-reviewed method was applied for the first time during the storage facility-permitting process. The two SFP applications submitted in 2021 successfully resulted in North Dakota Industrial Commission (NDIC) orders in 2022 authorizing the creation of the storage facility areas and amalgamation of pore space as well as establishing financial responsibility requirements. After approval of the SFPs, Minnkota filed in 2022 applications for permits to reenter the J-ROC 1 well and to drill two new wells—all with the intended purpose to become Class VI injection wells. To establish eligibility under the Internal Revenue Code for Section 45Q tax incentives, a monitoring, reporting, and verification (MRV) plan was prepared and submitted by Minnkota to EPA in 2022, resulting in the first such plan approved in North Dakota. Also in 2022, under the National Environmental Policy Act (NEPA), Minnkota prepared and submitted an environmental information volume (EIV) describing the proposed CCS project and associated potential environmental impacts. Based on the EIV, DOE determined that the proposed construction project required an environmental assessment, and Minnkota submitted the first draft in 2023 and a revised draft in 2024. Both submissions were followed by a public comment period. Subsequently, DOE issued a finding of no significant impact (FONSI) on September 13, 2024. A successful outreach program, strongly based in the production, presentation, and dissemination of informational material, fostered an environment to aid stakeholders in making informed decisions regarding the planned project. Opportunities for public input were provided at various steps along the way, including at county planning and zoning meetings, before and during the SFP administrative hearing, and during environmental assessment public comment periods. In addition, land/pore space owners and mineral owners had various points of contact, including granting access rights, securing pore space leasing, and mineral owner notifications. Based upon the successful storage facility permitting issued by NDIC, approval of the MRV plan by EPA, and receipt of a FONSI under the NEPA, Minnkota is continuing its pursuit of Project Tundra. In December 2023, the Office of Clean Energy Demonstrations under its Carbon Capture Demonstrations Projects Program announced funding for the capture system (Office of Clean Energy Demonstrations, 2023) and a proposal for CarbonSAFE Phase IV: Construction funding was submitted in March 2024 for the storage project. A go/no-go decision to proceed with construction and operations in the Broom Creek Formation is anticipated in 2024. References National Energy Technology Laboratory, CarbonSafe Initiative, https://netl.doe.gov/carbon-management/carbon-storage/carbonsafe (accessed August 2024). Office of Clean Energy Demonstrations, 2023, OCED selects three projects in CA, ND, and TX to reduce harmful carbon pollution, create new economic opportunities, and advance carbon reducing technologies, December, www.energy.gov/oced/articles/oced-selects-three-projects-ca-nd-and-tx-reduce-harmful-carbon-pollution-create-new (accessed August 2024).

Peck, Wesley↗

High temperature thermal energy storage, including a discussion of TES integrated into power plants

Storage temperatures of 260 C and above are considered. Basic considerations concerning energy thermal storage are discussed, taking into account general aspects of thermal energy storage, thermal energy storage integrated into power plants, thermal storage techniques and technical considerations, and economic considerations. A description of system concepts is provided, giving attention to a survey of proposed concepts, storage in unpressurized fluids, water storage in pressurized containers, the use of an underground lined cavern for water storage, a submerged thin insulated steel shell under the ocean containing pressurized water, gas passage through solid blocks, a rock bed with liquid heat transport fluid, hollow steel ingots, heat storage in concrete or sand, sand in a fluidized bed, sand poured over pipes, a thermal energy storage heat exchanger, pipes or spheres filled with phase change materials (PCM), macroencapsulated PCM with heat pipe concept for transport fluid, solid PCM removed from heat transfer pipes by moving scrapers, and the direct contact between PCM and transport fluid.

Turner, R. H.↗

Advanced onboard storage concepts for natural gas-fueled automotive vehicles

The evaluation of several advanced concepts for storing natural gas at reduced pressure is presented. The advanced concepts include adsorption on high surface area carbon, adsorption in high porosity zeolite, storage in clathration compounds, and storage by dissolution in liquid solvents. High surface area carbons with high packing density are the best low pressure storage mediums. A simple mathematical model is used to compare adsorption storage on a state of the art carbon with compression storage. The model indicates that a vehicle using adsorption storage of natural gas at 3.6 MPa will have 36 percent of the range, on the EPA city cycle, of a vehicle operating on a compression storage system having the same physical size and a peak storage pressure of 21 MPa. Preliminary experiments and current literature suggest that the storage capacity of state of the art carbons could be improved by as much as 50 percent, and that adsorption systems having a capacity equal to compression storage at 14 MPa are possible without exceeding a maximum pressure of 3.6 MPa.

Remick, R. J.↗

Fuel Cell Systems for First Lunar Outpost: Reactant Storage Options

A Lunar Surface Power Working Group was formed to review candidate systems for providing power to the first lunar outpost habitat. The working group concluded that the most attractive candidate included a photovoltaic unit, a fuel cell, a regenerator to recycle the reactants, and storage of oxygen and hydrogen gases. Most of the volume (97 percent) and weight (64 percent) are taken up by the reactants and their storage tank. The large volume is difficult to accommodate, and therefore, the working group explored ways of reducing the volume. An alternative approach to providing separate high pressure storage tanks is to use two of the descent stage propellant storage tanks, which would have to be wrapped with graphite fibers to increase their pressure capability. This saves 90 percent of the volume required for storage of fuel cell reactants. Another approach is to use the descent storage propellant tanks for storage of the fuel cell reactants as cryogenic liquids, but his requires a gas liquefication system, increases the solar array by 40 percent, and increases the heat rejection rate by 170 percent compared with storage of reactants as high pressure gases. For a high power system (greater than 20 kW) the larger energy storage requirements would probably favor the cryogenic storage option.

Nelson, P. A.↗

Terrestrial Energy Storage SPS Systems

Terrestrial energy storage systems for the SSP system were evaluated that could maintain the 1.2 GW power level during periods of brief outages from the solar powered satellite (SPS). Short-term outages of ten minutes and long-term outages up to four hours have been identified as "typical" cases where the ground-based energy storage system would be required to supply power to the grid. These brief interruptions in transmission could result from performing maintenance on the solar power satellite or from safety considerations necessitating the power beam be turned off. For example, one situation would be to allow for the safe passage of airplanes through the space occupied by the beam. Under these conditions, the energy storage system needs to be capable of storing 200 MW-hrs and 4.8 GW-hrs, respectively. The types of energy storage systems to be considered include compressed air energy storage, inertial energy storage, electrochemical energy storage, superconducting magnetic energy storage, and pumped hydro energy storage. For each of these technologies, the state-of-the-art in terms of energy and power densities were identified as well as the potential for scaling to the size systems required by the SSP system. Other issues addressed included the performance, life expectancy, cost, and necessary infrastructure and site locations for the various storage technologies.

Brandhorst, Henry W., Jr.↗

Storage Characteristics of Lithium Ion Cells

Lithium ion cells are being developed under the NASA/Air Force Consortium for the upcoming aerospace missions. First among these missions are the Mars 2001 Lander and Mars 2003 Lander and Rover missions. Apart from the usual needs of high specific energy, energy density and long cycle life, a critical performance characteristic for the Mars missions is low temperature performance. The batteries need to perform well at -20 C, with at least 70% of the rated capacity realizable at moderate discharge rates (C/5). Several modifications have been made to the lithium ion chemistry, mainly with respect to the electrolyte, both at JPL' and elsewhere to achieve this. Another key requirement for the battery is its storageability during pre-cruise and cruise periods. For the Mars programs, the cruise period is relatively short, about 12 months, compared to the Outer Planets missions (3-8 years). Yet, the initial results of our storage studies reveal that the cells do sustain noticeable permanent degradation under certain storage conditions, typically of 10% over two months duration at ambient temperatures, attributed to impedance buildup. The build up of the cell impedance or the decay in the cell capacity is affected by various storage parameters, i.e., storage temperature, storage duration, storage mode (open circuit, on buss or cycling at low rates) and state of charge. Our preliminary studies indicate that low storage temperatures and states of charge are preferable. In some cases, we have observed permanent capacity losses of approx. 10% over eight-week storage at 40 C, compared to approx. 0-2% at O C. Also, we are attempting to determine the impact of cell chemistry and design upon the storageability of Li ion cells.

Ratnakumar, B. V.↗

Researching the Effects of Long-Term Dry Storage on Commercial Spent Nuclear Fuel

When the fuel in a nuclear reactor no longer contributes efficiently to power production, it is discharged and stored onsite in a water-filled spent fuel pool. When nuclear power plants in the United States were originally designed, it was expected that onsite storage would be temporary. The used nuclear fuel, also known as spent nuclear fuel (SNF), was to be removed from the storage pools after only a few years of cooling and sent for reprocessing. However, commercial reprocessing was not implemented in the United States, and utility spent fuel pools began running out of room. In order to continue power production, nuclear utilities began expanding onsite fuel storage capacities, first by increasing the density of fuel in the fuel pool racks, and then by developing and implementing dry storage casks. The dry storage casks are stored onsite by each utility at a licensed and secured independent spent fuel storage installation (ISFSI). Dry storage casks are robust systems typically consisting of a sealed metal cylinder surrounded by a combination of steel and concrete to provide radiation shielding. The first dry storage casks were loaded with SNF in 1986. Currently there are over 3,000 loaded dry storage casks, and approximately 200 new casks are being placed into service annually at operating nuclear power plants nationwide. Multiple nuclear power plant sites in the United States have shut down and completed decommissioning activities except for the removal of fuel in dry storage. Eventually, the 75,000+ tons of discharged SNF at more than 70 secured locations will need to be safely and securely transported to a new location(s) for eventual disposition. The continued safety and security of this material must be assured.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nano-enhanced solid-state hydrogen storage: Balancing discovery and pragmatism for future energy solutions

Nanomaterials have revolutionized the battery industry by enhancing energy storage capacities and charging speeds, and their application in hydrogen (H 2 ) storage likewise holds strong potential, though with distinct challenges and mechanisms. H 2 is a crucial future zero-carbon energy vector given its high gravimetric energy density, which far exceeds that of liquid hydrocarbons. However, its low volumetric energy density in gaseous form currently requires storage under high pressure or at low temperature. This review critically examines the current and prospective landscapes of solid-state H 2 storage technologies, with a focus on pragmatic integration of advanced materials such as metal-organic frameworks (MOFs), magnesium-based hybrids, and novel sorbents into future energy networks. These materials, enhanced by nanotechnology, could significantly improve the efficiency and capacity of H 2 storage systems by optimizing H 2 adsorption at the nanoscale and improving the kinetics of H 2 uptake and release. We discuss various H 2 storage mechanisms—physisorption, chemisorption, and the Kubas interaction—analyzing their impact on the energy efficiency and scalability of storage solutions. The review also addresses the potential of “smart MOFs”, single-atom catalyst-doped metal hydrides, MXenes and entropy-driven alloys to enhance the performance and broaden the application range of H 2 storage systems, stressing the need for innovative materials and system integration to satisfy future energy demands. High-throughput screening, combined with machine learning algorithms, is noted as a promising approach to identify patterns and predict the behavior of novel materials under various conditions, significantly reducing the time and cost associated with experimental trials. In closing, we discuss the increasing involvement of various companies in solid-state H 2 storage, particularly in prototype vehicles, from a techno-economic perspective. In conclusion, this forward-looking perspective underscores the necessity for ongoing material innovation and system optimization to meet the stringent energy demands and ambitious sustainability targets increasingly in demand.

25 ENERGY STORAGE↗

Performance evaluation of a dynamic wall integrated with active insulation and thermal energy storage systems

Thermal energy storage systems in buildings can store cooling/heating energy during non-peak load hours or when renewable energy sources are available for later use when demanded. Using the building envelope as a thermal battery can help to shave the peak load, reduce the burden in electric grids, and enhance the occupant's thermal comfort. Sensible energy storage on wall systems such as thermally activated building systems can provide an active thermal storage strategy. However, most of the stored energy is used through passive means directed by the thermal lag, which can impede the on-demand release of the stored energy. Integrating active insulation systems with building thermal storage systems can increase the flexibility of charging and discharging time and duration. In this study, a wall system equipped with an active insulation system and thermally activated storage system was designed, and its performance on active cooling energy contribution was studied. The performances of energy storage (charging), release (discharging) of the thermal energy storage energy, and the active insulation system were studied separately and together as an integrated system. Results showed that the thermal properties of the thermal energy storage core material and the pipe spacing of both embedded pipes in the thermal energy storage and hydronic pipes used in the active insulation system affected the wall performance the most out of all the tested wall system parameters. During discharging, the heat flux into the wall was as high as 81.92 W/m 2 . This active insulation system's dynamic R-value varied between less than 1ft 2 •°F•h/BTU (0.18 m 2 •K/W) to 98% of the equally thick foam insulation's R-value.

25 ENERGY STORAGE↗

Off-design operation and performance of pumped thermal energy storage

In this article, we describe off-design models and control strategies for a Pumped Thermal Energy Storage (PTES) system that uses liquid thermal energy storage: specifically molten salt for hot storage and methanol for cold storage. Off-design conditions arise when load-following, or due to variations in storage tank temperatures or ambient temperatures. We propose a control strategy that uses inventory control to manage the mass flow rate in the thermodynamic cycles, which facilitates load following. We also propose a control strategy for the storage fluid mass flow rates, which are varied to ensure the molten salt is maintained at its design temperature. This maximizes efficiency and minimizes problems with salt freezing or degradation. The cold storage fluid mass flow rate is varied so that the cold tanks have the same state-of-charge as the hot tanks. This leads to variations in cold fluid temperature, but these variations are shown to be acceptably small (e.g. 7.5% increase), and this control method is shown to be simpler and more efficient than an alternative strategy where tanks become unbalanced. The ambient temperature and storage tank temperatures are moved ±50 °C from the design values and the impact on power, duration, and tank temperatures is quantified. Results demonstrate that the proposed control strategy is stable and self-correcting - that is, storage temperatures converge on stable values after two-to-three charge-discharge cycles. When inputs return to design values, the system returns to its design point after two charge-discharge cycles. We also demonstrate that inventory control enables delivery of the target power output even when off-design conditions exist that would normally reduce the power output.

25 ENERGY STORAGE↗

Quantifying CO 2 storage efficiency factors in hydrocarbon reservoirs. A detailed look at CO 2 Enhanced Oil Recovery

Carbon dioxide (CO 2 ) enhanced oil recovery (EOR) will likely be the primary means of geologic CO 2 storage during the early stages of commercial-scale carbon capture and storage (CCS) because of the inherent economic incentives as well as the abundant experience and demonstrated success in the United States, where CO 2 EOR has been employed since 1974. The work presented here estimates CO 2 storage efficiency factors in CO 2 EOR operations using a unique industry database of CO 2 EOR sites and 12 different reservoir simulation models. The simulation models encompass fluvial clastic and shallow shelf carbonate depositional environments for reservoir depths of 1219 and 2438 m (4000 and 8000 feet) and 7.6-, 20-, and 64-m (25-, 66-, and 209-foot)-thick pay zones. A novel statistical modeling technique incorporating the Michaelis–Menten function is used to generate empirical percentile estimates of CO 2 storage efficiency factors. West Texas San Andres dolomite water alternating gas (WAG) CO 2 flood performance data were used to derive P10, P50, and P90 CO 2 storage efficiency factors of 0.76, 1.28, and 1.74 Mscf/STB (stock tank barrel) of original oil in place. Median CO 2 storage efficiency factors from continuous CO 2 injection following conventional waterflood varied from 15% to 61% and 8% to 40% for fluvial clastic and shallow shelf carbonate simulation models, respectively, while those from WAG injection varied from 14% to 42% and 8% to 31%, respectively. Variation in the CO 2 storage efficiency factors was largely attributable to reservoir depth (a surrogate for reservoir pressure and temperature) and lithology (clastic versus carbonate). The results of this work provide practical information that can be used to quantify CO 2 storage resource estimates in oil reservoirs during CO 2 EOR operations (as opposed to storage following depletion) and the uncertainty associated with those estimates.

54 ENVIRONMENTAL SCIENCES↗

Injection data analysis using material balance time for CO 2 storage capacity estimation in deep closed saline aquifers

Estimating the ultimate storage capacity of deep saline aquifers is important to address the formation potential to store the envisioned large volumes of CO 2 . Injection data (i.e. injection rate, bottomhole pressure, and cumulative injected volume of CO 2 ) are routinely recorded during storage operations. These data contain valuable information on the subsurface (e.g. the reservoir pore volume and the formation storage capacity) that can be extracted. In this paper, we present a two-step graphical technique to infer the pore volume and the ultimate storage capacity of closed saline aquifers by analyzing the available injection data. First, the pore volume is inferred through adapting the concept of the material balance time. Material balance time is an approximate superposition time function developed to interpret production data from oil and gas wells operating at variable pressure/rate conditions during the boundary-dominated flow period. Using material balance techniques, the ultimate storage capacity is then estimated through linear extrapolation of the average pressure trend to the maximum allowable pressure the formation can withstand. The average pressure is not available in practice, but is can be obtained from the injection data. Two approaches are presented in this study to calculate the average pressure; namely the rigorous and the approximate approaches. Unlike the rigorous approach, the approximate approach does not require a prior knowledge of some reservoir properties (e.g. relative permeability, absolute permeability, formation porosity and thickness) to calculate the average pressure. To investigate its potential and reliability in analyzing CO 2 injection data, the proposed technique is applied to four synthetic cases representing different well operating conditions. Results indicate that the approximate approach consistently overestimates the actual (simulated) storage capacity as compared to the rigorous approach. The agreement - between the inferred and the simulated reservoir pore volume, and between the analytical and numerical estimates of storage capacity - validates the potential application of the technique to CO 2 storage in closed saline aquifers. The technique is further substantiated through application to a field data set utilized from a commercial-scale geological storage (CGS) project. Finally, field data interpretation shows that the proposed technique can be utilized to identify the degree of hydraulic continuity and reservoir compartmentalization within a target formation by interpreting the corresponding pressure and rate responses.

02 PETROLEUM↗

On the marginal value of electricity storage

We investigate the problem of characterizing the economic value of energy storage capacity to a wind power producer (WPP) that sells its energy in a conventional two-settlement electricity market. The WPP can offer a forward contract to supply power in the day-ahead market, subject to financial penalties for imbalances between the contracted power and the power that is delivered in real-time. We consider the setting in which the WPP has access to a co-located energy storage system, and can thus reshape its wind power production subject to its storage capacity constraints. Modeling wind power as a random process, we show that the problem of determining optimal forward contract offerings—given recourse with storage—is convex. We further establish that the maximum expected profit is concave and non-decreasing in the energy storage capacity, which reveals that the greatest marginal benefit from energy storage is derived from initial investment in small storage capacity. We provide a characterization of the marginal value of small energy storage capacity to the WPP. The formulae we derive shed light on the relationship between the value of storage and certain statistical measures of variability in the underlying wind power process.

25 ENERGY STORAGE↗

Pseudocapacitive Lithium-Ion Storage in Oriented Anatase TiO2 Nanotube Arrays

We report on the synthesis and electrochemical properties of oriented anatase TiO{sub 2} nanotube (NT) arrays as electrodes for Li-ion batteries. The TiO{sub 2} NT electrodes displayed both pseudocapacitive Li{sup +} storage associated with the NT surface and the Li{sup +} storage within the bulk material. The relative contribution of the pseudocapacitive and bulk storages depends strongly on the scan rate. While the charges are stored primarily in the bulk at low scan rates (<< 1 mV/s), the surface storage dominates the total storage capacity at higher scan rates (>1 mV/s). The storage capacity of the NT electrodes as a function of charge/discharge rates showed no dependence on the NT film thickness, suggesting that the Li{sup +} insertion/extraction processes occur homogeneously across the entire length of NT arrays. These results indicated that the electron conduction along the NT walls and the ion conduction within the electrolyte do not cause significant hindering of the charge/discharge kinetics for NT electrode architectures. As a result of the surface pseudocapacitive storage, the reversible Li{sup +} storage capacities for TiO{sub 2} NT electrodes were higher than the theoretical storage capacity for bulk anatase TiO{sub 2} materials.

25 ENERGY STORAGE↗

Permeability and Mineral Composition Evolution of Primary Seal and Reservoir Rocks in Geologic Carbon Storage Conditions

It has been reported that deep saline aquifers represent the largest geologic CO 2 storage resource. To better predict containment effectiveness and long-term reservoir behavior of these formations, it is important to understand the potential geochemically induced changes to the porosity and permeability of both the primary sealing formation and CO 2 storage formation rocks. To investigate these potential changes, an experimental study to probe the geochemical interactions of CO 2 /brine/rock system under geologic CO 2 storage conditions was conducted in a static reaction system. Marine shale (primary sealing formation) and Lower Tuscaloosa sandstone (CO 2 storage formation) core samples taken from the Plant Daniel CO 2 storage test site (Jackson County, Mississippi) were exposed to CO 2 -saturated brine in a batch reactor at relevant geologic storage conditions (85°C and 23.8 MPa CO 2 pressure) for 6 months. X-ray diffraction, scanning electron microscopy, computed tomography, and brine chemistry analyses were performed before and after the exposure. Permeability measurements from the marine shale and sandstone core samples before and after CO 2 /brine exposure indicated a significant effective permeability change. Sealing marine shale permeability increased following exposure while the permeability of the sandstone from the storage formation was observed to decrease. Analysis results of the primary sealing formation sample (marine shale) at the Plant Daniel CO 2 storage test site have not been reported before. In conclusion, the permeability decrease of the Lower Tuscaloosa sandstone sample reported in this study verifies the results reported in a previous study. These results have implications for the integrity of the primary seal in a CO 2 storage setting.

01 COAL, LIGNITE, AND PEAT↗

Developing a concept for a national used fuel interim storage facility in the United States

In the United States (U.S.) the nuclear waste issue has plagued the nuclear industry for decades. Originally, spent fuel was to be reprocessed but with the threat of nuclear proliferation, spent fuel reprocessing has been eliminated, at least for now. In 1983, the Nuclear Waste Policy Act of 1982 [1] was established, authorizing development of one or more spent fuel and high-level nuclear waste geological repositories and a consolidated national storage facility, called a 'Monitored Retrievable Storage' facility, that could store the spent nuclear fuel until it could be placed into the geological repository. Plans were under way to build a geological repository, Yucca Mountain, but with the decision by President Obama to terminate the development of Yucca Mountain, a consolidated national storage facility that can store spent fuel for an interim period until a new repository is established has become very important. Since reactor sites have not been able to wait for the government to come up with a storage or disposal location, spent fuel remains in wet or dry storage at each nuclear plant. The purpose of this paper is to present a concept developed to address the DOE's goals stated above. This concept was developed over the past few months by collaboration between the DOE and industry experts that have experience in designing spent nuclear fuel facilities. The paper examines the current spent fuel storage conditions at shutdown reactor sites, operating reactor sites, and the type of storage systems (transportable versus non-transportable, welded or bolted). The concept lays out the basis for a pilot storage facility to house spent fuel from shutdown reactor sites and then how the pilot facility can be enlarged to a larger full scale consolidated interim storage facility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Value of Energy Storage for Grid Applications

This analysis evaluates several operational benefits of electricity storage, including load-leveling, spinning contingency reserves, and regulation reserves. Storage devices were simulated in a utility system in the western United States, and the operational costs of generation was compared to the same system without the added storage. This operational value of storage was estimated for devices of various sizes, providing different services, and with several sensitivities to fuel price and other factors. Overall, the results followed previous analyses that demonstrate relatively low value for load-leveling but greater value for provision of reserve services. The value was estimated by taking the difference in operational costs between cases with and without energy storage and represents the operational cost savings from deploying storage by a traditional vertically integrated utility. The analysis also estimated the potential revenues derived from a merchant storage plant in a restructured market, based on marginal system prices. Due to suppression of on-/off-peak price differentials and incomplete capture of system benefits (such as the cost of power plant starts), the revenue obtained by storage in a market setting appears to be substantially less than the net benefit provided to the system. This demonstrates some of the additional challenges for storage deployed in restructured energy markets.

24 POWER TRANSMISSION AND DISTRIBUTION↗