Literature Review of Selected Publications Relevant to Carbon Dioxide Pipeline and Storage Systems

The annotated bibliographies provided in this document focus on identifying and reviewing environmental impact statements (EIS), environmental assessments (EA), and scientific literature relevant to aspects of CO 2 pipeline and storage construction and operation. The purpose of these summaries is to aid stakeholders responsible for the preparation of documents compliant with the National Environmental Policy Act (NEPA) requirements to have access to a quick and comprehensive guide of the literature that can inform their activities. They aim to inform the development of EISs and EAs by identifying potential environmental concerns and mitigation strategies. The annotated bibliographies captured in this document cover the general environmental assessment and impact topics relevant to CO 2 pipeline and storage construction and operation activities, with the subject of waste creation and handling being specifically pulled out into its own section. The reasoning behind a dedicated section for waste is that many EAs and EISs focus on the description of waste and its impacts, be it caused in routine operation or as a result of an accident.

54 ENVIRONMENTAL SCIENCES↗

Developing A New NG Super-Absorbent Polymer (NG-SAP) for a Practical NG Storage System with Low Pressure, Ambient Temperature, and High Energy Density

This R&D project proposed a systematical study to develop a new class of NG super-absorbent polymer (NG-SAP) with the objective to achieve similar CNG volumetric storage level ~250 cm 3 -STP/cm 3 and fast sorption-desorption kinetics at ambient temperature but lower operational pressure (<100 bar). We suggested two consecutive research phases, including (i) a systematical investigation of various polymer systems to identify the suitable classes that can exhibit methane (C1) binding energy in the range of 20-25 kJ/mol and then (ii) focusing on the potential class polymers to identify the specific structure and morphology that can achieve the project objective.In first research phase (1st year), the major tasks included design and synthesis of several representative polymers with various structure attributes, examining their molecular structures, pore morphology, and BET surface area as the prepared samples, and then studying their C1 binding energy and sorption capacity.

03 NATURAL GAS↗

Advanced Turbine Airfoils for Efficient CHP Systems: Energy Storage Integration Analysis

This report documents the energy storage systems (ESS) integration portion of the work conducted under the Office of Energy Efficiency and Renewable Energy (EERE) advanced Manufacturing Office (AMO) Lab Call DE-LC-000L059 project titled "Advanced Turbine Airfoils for Efficient CHP Systems." The objective of this work is to analyze the previously-developed combined heat and power (CHP) plant with the upgraded gas turbine to include an ESS to improve the operational flexibility. The analysis includes identifying a candidate CHP configuration for the ESS integration and identifying possible storage systems to be integrated. A qualitative analysis was made to down select possible storage technologies and a techno-economic analysis (TEA) was made for the CHP system with the selected storage technology.

20 FOSSIL-FUELED POWER PLANTS↗

Savings in Action: Lessons from Observed and Modeled Residential Solar Plus Storage Systems

The electric grid is rapidly evolving as small-scale, demand-side resources play increasingly important roles in grid operations and decarbonization. Maximizing the potential of demand-side resources involves incentivizing electricity customers to use those resources in ways that benefit the broader electrical grid. These incentives depend largely on the electricity cost savings that customers can realize from demand-side resource adoption. Determining these potential cost savings is a complex task. Cost savings depend on numerous factors, including the characteristics of different technologies, the algorithms that control these devices, system performance, customer behavior, electricity rate structures, and climatic factors. Another challenge is that estimated cost savings are frequently based on modeled rather than observed system performance, particularly in the academic literature. In this study, we begin to fill the gap in empirical research of demand-side resources using data from a new construction residential community equipped with rooftop solar and storage (S+S) in Arizona. We use these data to analyze the factors that determine customer electricity cost savings and emissions impacts of S+S in the real world. We then compare these data to modeled system performance to understand how models deviate from real-world outcomes. Based on these findings, we explore ways to improve such models and, conversely, use modeled results to suggest improvements to actual S+S deployment. The results of these analyses can be summarized in four key findings: 1) rate structures play a central role in the grid and customer value of demand-side resources; 2) certain customers can benefit more from demand-side resource adoption than others; 3) modeled battery dispatch and sizing reveals opportunities for additional cost savings; and 4) optimal dispatches can reduce grid emissions while maximizing bill savings.

14 SOLAR ENERGY↗

Expanding market opportunities: cogeneration strategies for integrated PWR and thermal energy storage systems

We assess the economic viability of nuclear cogeneration by investigating three different modes—fixed dispatch, fully flexible dispatch, and flexible dispatch with minimum heat supply requirements. The analysis focuses on an existing pressurized water reactor (PWR) integrated with thermal energy storage (TES). Heat production costs are estimated under these modes for two U.S. electricity markets: the Electric Reliability Council of Texas (ERCOT) and the Pennsylvania–New Jersey–Maryland Interconnection (PJM). A sensitivity analysis examines profitability at varying heat market prices. Results indicate that fixed heat dispatch inflates heat production costs, often rendering projects economically feasible only at higher heat price levels. Fully-flexible dispatch lowers heat production costs by an average of 43 % compared to fixed dispatch. However, the current 30 % thermal dispatch limit may be insufficient to serve high baseline industrial demands cost‐effectively; higher maximum dispatch rates could enhance project economics. Markets with higher and more volatile electricity prices (e.g., ERCOT) offer greater total energy sales potential (i.e., heat and electricity), but also increase opportunity costs when heat production scheduling restrictions are imposed. In contrast, lower-price, less volatile markets (e.g., PJM) experience smaller impacts from such constraints and provide greater flexibility in accommodating varying cogeneration modes. In conclusion, these findings provide a framework to guide nuclear plant operators in aligning cogeneration strategies with industrial process requirements and electricity market conditions.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Molten Salt Thermal Energy Storage Systems

The feasibility of storing thermal energy at temperatures of 450 C to 535 C in the form of latent heat of fusion was examined for over 30 inorganic salts and salt mixtures. Alkali carbonate mixtures were chosen as phase-change storage materials in this temperature range because of their relatively high storage capacity and thermal conductivity, moderate cost, low volumetric expansion upon melting, low corrosivity, and good chemical stability. Means of improving heat conduction through the solid salt were explored.

Maru, H. C.↗

Re-Designing the CSP Thermal Energy Storage System to Enable Higher-Temperature Performance at Reduced Cost (Final Technical Report)

Current commercial concentrating solar power (CSP) plants distinguish themselves from ordinary photovoltaic (PV) power plants by storing enough collected energy to enable generation for several hours after the sun goes down. CSP plants store this energy in the sensible heat of nitrate salts in large metallic storage tanks. Stainless-steel AISI 347H (SS347H) is needed for the hot tank operating at about 565 degrees C whereas carbon steel is sufficient for the cold-tank materials. Two-tank nitrate-salt thermal energy storage (TES) is presently in use in several trough-based CSP plants in Europe and in the U.S., operating up to about 390 degrees C. Three commercially operating tower-based CSP plants - Gemasolar in Spain, Crescent Dunes in Nevada, and Noor III in Morocco - use the same approach, storing nitrate salts at temperatures up to 580 degrees C. SS347H is many times more expensive than carbon steel and constitutes a significant cost element in today's CSP plants. Hence, CSP developers need to close the cost gap with PV-based solar plants by making cost reductions in every system of the plant. Redesigning the TES tanks is one opportunity for cost reduction.

14 SOLAR ENERGY↗

Large Format Multifunction 2-Terabyte Optical Disk Storage System

The Kodak Digital Science OD System 2000E automated disk library (ADL) base module and write-once drive are being developed as the next generation commercial product to the currently available System 2000 ADL. Under government sponsorship with the Air Force's Rome Laboratory, Kodak is developing magneto-optic (M-O) subsystems compatible with the Kodak Digital Science ODW25 drive architecture, which will result in a multifunction (MF) drive capable of reading and writing 25 gigabyte (GB) WORM media and 15 GB erasable media. In an OD system 2000 E ADL configuration with 4 MF drives and 100 total disks with a 50% ration of WORM and M-O media, 2.0 terabytes (TB) of versatile near line mass storage is available.

Kaiser, David R.↗

Data Placement Optimization for ATLAS in a Multi-Tiered Storage System within a Data Center

Scientific experiments and computations, especially in High Energy Physics, are generating and accumulating data at an unprecedented rate. Effectively managing this vast volume of data while ensuring efficient data analysis poses a significant challenge for data centers, which must integrate various storage technologies. This paper proposes addressing this challenge by designing and developing a precise data popularity prediction model utilizing state-of-theart AI/ML techniques. This model is crafted from the analysis of ATLAS data and access patterns. It enables us to migrate infrequently accessed data to more economical storage media, such as tape drives, while storing frequently accessed data on faster yet costlier storage media like HDD or SSD. This strategic approach ensures data is placed optimally into the appropriate storage classes, thereby maximizing storage capacity while minimizing data access latency for end-users. Furthermore, the paper includes a performance evaluation of the prediction model using various key metrics such as F1 score, accuracy, precision and recall. Finally, we present a prototype use case, leveraging real-world file access data to assess the model’s impact on performance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Advanced compact holographic data storage system

In this paper, recent technology progress developing this CHDS at JPL will be presented. The recent applications of the CHDS to optical pattern recognition systems as a high density, high transfer rate memory bank will also be discussed.