Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thick Target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

A platform for non-local thermodynamic equilibrium atomic physics research using the buried layer target approach at a kJ level laser facility

Here we present a design and first use of a kJ level laser facility for research of non-local thermodynamic equilibrium atomic physics using the buried layer target method. The target design included a metal layer buried inside a plastic tamper with thicknesses tailored to the expected laser intensities. The target was illuminated from each side by two laser beams with intensities of 0.5–5 × 10 14 W/cm 2 . The advanced diagnostic suite included static and time-resolved imagers and spectrometers with various spectral resolutions. A 3D printed dual elliptically curved spectrometer is presented, and its results are compared to a traditional crystal spectrometer. Experimental results and radiation hydrodynamic simulations demonstrate that the target achieved the desired thermodynamic conditions of n e ≈ 10 21 –10 22 cm -3 and T e ≈ 1–2 keV.

3D printing↗

Optical resonant ultrasound spectroscopy for spherical target characterization

A new non-contact resonant ultrasound spectroscopic technique is employed to determine the response characteristics of spherical fusion targets, with particular emphasis on both the displacement sensitivity and frequency response of the technique. The optical experimental method is based on photorefractive optical lock-in detection scheme with narrow bandwidth amplification to measure phase variations in light scattered from optically rough, continuously vibrating surfaces with very high, linear sensitivity and a noise level on the order of 10.6 nanometers RMS. This high sensitivity is needed to determine the vibrational modes of the gas inside an spherical target separately from the elastic modes of the containment shell. These measurements can be used to calculate the pressure and density of the internal gas. This approach is also used to discriminate between nearly-degenerate resonant modes characteristic of the frequency spectrum when the target fabrication is inadequate (non-uniform shell thickness, misalignment of hemispheres) or when the Deuteriumrrritium solid fuel inside the target is not symmetrically distributed at cryogenic temperatures. Asymmetries in the fuel layering and geometric perturbations disturb the target implosion process creating deleterious effects in fusion energy generation. The technique is applied to determine the modal characteristics of a target sphere with known response from 100 KHz to 450 KHz. The results demonstrate the unique capabilities of the optical lock-in detection method to measure very small resonant ultrasonic signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structure of {sup 46}Ti at low excitation energy

The nucleus {sup 46}Ti has been studied with the reaction {sup 42}Ca({sup 7}Li,p2n){sup 46}Ti at a bombarding energy of 31 MeV. Thin target foils backed with a thick Au layer were used. Five new levels of negative parity were observed. Several lifetimes have been determined with the Doppler shift attenuation method. Low-lying experimental negative-parity levels are assigned to three bands with K{sup {pi}=}3{sup -}, 0{sup -}, and 4{sup -}, which are interpreted in terms of the large-scale shell model, considering particle-hole excitations from d{sub 3/2} and s{sub 1/2} orbitals. Shell model calculations were performed using a few effective interactions. However, good agreement was not achieved in the description of either negative- or positive-parity low-lying levels.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Resputtering effect during MgO buffer layer deposition by magnetron sputtering for superconducting coated conductors

In this study, MgO thin films were deposited by radio-frequency magnetron sputtering. The film thickness in the deposition area directly facing the target center obviously decreased compared with that in other areas. This reduction in thickness could be attributed to the resputtering effect resulting from bombardment by energetic particles mainly comprising oxygen atoms and negative oxygen ions. The influences of deposition position and sputtering pressure on the deposition rate were investigated. Resputtering altered the orientation of the MgO film from (111) to (001) when the film was deposited on a single crystal yttria-stabilized zirconia substrate. The density distribution of energetic particles was calculated on the basis of the measured thicknesses of the MgO films deposited at different positions. The divergence angle of the energetic particle flux was estimated to be approximately 15°. The energetic particle flux might be similar to the assisting ion flux in the ion beam assisted deposition process and could affect the orientation of the MgO film growth.

36 MATERIALS SCIENCE↗

D 2 and DT Liquid-Layer Target Shots on NIF

Experiments at the National Ignition Facility (NIF) using targets containing a Deuterium-Tritium (DT) fuel layer have, until recently, required that a high-quality layer of solid deuterium-tritium (herein referred to as an "ice-layer") be formed in the capsule. The development of a process to line the inner surface of a target capsule with a foam layer of a thickness that is typical of icelayers has resulted in the ability to field targets with liquid layers wetting the foam. Successful fielding of liquid-layer targets on NIF required not only a foam lined capsule, but also changes to the capsule filling process and the manner with which the inventory is maintained in the capsule. Additionally, changes to target heater power and the temperature drops across target components were required in order to achieve the desired range of shot temperatures. These changes, and the target's performance during four target shots on NIF will be discussed.

42 ENGINEERING↗

New Mie Scattering Diffuse Targets Development and Characterization

Earth science remote sensing observations require the detection and measurement of light originating from bright targets, such as clouds, and darker targets, such as an open ocean. This requirement drives the need to design, develop, and characterize improved calibration targets in support of current and future NASA instruments. New diffuse targets to be used as spectral albedo calibration standards were developed and characterized. The new targets based on fused silica or/and pressed and sintered Polytetrafluoroethylene (PTFE) were developed to be Earth scene specific. The various reflectance levels are achieved by modifying the material parameters, thickness, and surface finish. The new targets were characterized in laboratory and simulated space environments. We acquired high accuracy reflectance and transmittance data using a precision optical scatterometer and spectrophotometer located in the NASA Goddard Space Flight Center (GSFC) Diffuser Calibration Lab. The Total hemispherical reflectance (THR) and Bidirectional Reflectance Distribution Function (BRDF) were measured over the range of solar incident and scattered elevation and azimuthal angles typically realized on orbit by remote sensing instruments. We intend to space certify the new calibration targets after concluding on-orbit testing on the International Space Stations (ISS) scheduled for the second half of 2023.

Georgi Georgiev↗

Design-informed neutronics assessment of long-lived fission product transmutation in a tokamak fusion reactor blanket

This study presents a neutronics-based assessment of the feasibility and viability of transmuting six major long-lived fission products (LLFPs) from light-water reactors, namely 99 Tc, 129 I, 79 Se, 93 Zr, 126 Sn, and 135 Cs, within the blanket region of a tokamak fusion reactor, using the MIT ARC design as a concrete fusion configuration. Monte Carlo neutronics simulations were performed to evaluate LLFP transmutation and to compare the results with a reference boiling water reactor (BWR). The results indicate that transmutation of all six LLFPs is neutronics-feasible in fusion reactors, with transmutation half-lives significantly shorter than their natural decay half-lives. For elemental targets, transmutation of 135 Cs, 126 Sn, and 93 Zr was found potentially viable, as the net mass transmuted exceeded that achievable in the reference BWR under identical target volume and irradiation time. When isotopically separated targets were considered, transmutation of 126 Sn and 93 Zr appeared potentially viable. A parametric study demonstrated that plasma geometry modifications can enhance local neutron flux, increasing the transmuted 93 Zr mass by approximately 33% and reducing the transmutation half-life from approximately 240 years to 180 years. Repositioning the target and adjusting material layer thickness reduced the transmutation half-life of 93 Zr to 67 years and increased the net mass transmuted by a factor of 50. Furthermore, these results demonstrate that fusion reactors can enable LLFP transmutation beyond the practical limits of thermal fission reactors and highlight the critical role of reactor and blanket design optimization. Engineering and fuel-cycle considerations required for deployment are beyond the scope of this neutronics-focused study.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mono-energetic ion beam acceleration in solitary waves during relativistic transparency using high-contrast circularly polarized short-pulse laser and nanoscale targets

In recent experiments at the Trident laser facility, quasi-monoenergetic ion beams have been obtained from the interaction of an ultraintense, circularly polarized laser with a diamond-like carbon target of nm-scale thickness under conditions of ultrahigh laser pulse contrast. Kinetic simulations of this experiment under realistic laser and plasma conditions show that relativistic transparency occurs before significant radiation pressure acceleration and that the main ion acceleration occurs after the onset of relativistic transparency. Associated with this transition are a period of intense ion acceleration and the generation of a new class of ion solitons that naturally give rise to quasi-monoenergetic ion beams. An analytic theory has been derived for the properties of these solitons that reproduces the behavior observed in kinetic simulations and the experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of {sup 25}Al+p resonant elastic scattering for studying the {sup 25}Al(p,{gamma}){sup 26}Si

Proton resonant states in {sup 26}Si have been studied by the resonant elastic scattering of {sup 25}Al+p with a {sup 25}Al radioactive ion beam at 2.863 MeV/nucleon bombarding a thick H{sub 2} gas target with the inverse kinematics method at the low-energy RI beam facility CRIB (CNS Radioactive Ion Beam separator), University of Tokyo. The properties of these resonance states are important to better determine the production rates of {sup 25}Al(p,{gamma}){sup 26}Si reaction, which is one of the astrophysically important nuclear reactions to understand the production of the ground state of {sup 26}Al, the emitter of its characteristic 1.809-MeV gamma-ray, under the explosive stellar environments such as novae and X-ray bursts. In this work, several resonances above the proton threshold level have been observed with a high statistics and background free through a covered the range of excitation energies from E{sub x}{approx} 6.8 to 8.2 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of NbC thin films for soft X-ray multilayer applications

Compound materials are being used in soft x-ray and Extreme ultraviolet (EUV) optics applications. Structural properties of compound materials changes drastically when ultrathin films are formed from bulk material. Structural properties need to be investigated to determine the suitability of compound materials in soft x-ray multilayer applications. In the present study Niobium carbide (NbC) thin films were deposited using ion beam sputtering of an NbC target on Si (100) substrate. Thickness roughness and film mass density was determined from the X-ray reflectivity (XRR) data. XRR data revealed that the film mass density was increasing with increase in film thickness. For 500Ǻ thick film, mass density of 6.85 g/cm{sup 3}, close to bulk density was found. Rms roughness for all the films was less than 10Å. Local structure of NbC thin films was determined from EXAFS measurements. The EXAFS data showed an increase in Nb-C and Nb-(C)-Nb peak ratio approaches towards bulk NbC with increasing thickness of NbC. From the present study, NbC thin films were found suitable for actual use in soft x-ray multilayer applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamics and structure of self-generated magnetics fields on solids following high contrast, high intensity laser irradiation

The dynamics of self-generated magnetic B-fields produced following the interaction of a high contrast, high intensity (I > 10{sup 19 }W cm{sup −2}) laser beam with thin (3 μm thick) solid (Al or Au) targets is investigated experimentally and numerically. Two main sources drive the growth of B-fields on the target surfaces. B-fields are first driven by laser-generated hot electron currents that relax over ∼10–20 ps. Over longer timescales, the hydrodynamic expansion of the bulk of the target into vacuum also generates B-field induced by non-collinear gradients of density and temperature. The laser irradiation of the target front side strongly localizes the energy deposition at the target front, in contrast to the target rear side, which is heated by fast electrons over a much larger area. This induces an asymmetry in the hydrodynamic expansion between the front and rear target surfaces, and consequently the associated B-fields are found strongly asymmetric. The sole long-lasting (>30 ps) B-fields are the ones growing on the target front surface, where they remain of extremely high strength (∼8–10 MG). These B-fields have been recently put by us in practical use for focusing laser-accelerated protons [B. Albertazzi et al., Rev. Sci. Instrum. 86, 043502 (2015)]; here we analyze in detail their dynamics and structure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a cryogenically cooled platform for the Magnetized Liner Inertial Fusion (MagLIF) Program [Development of a cryogenically-cooled platform for the Magnetized Liner Inertial Fusion (MagLIF) Concept]

A cryogenically cooled hardware platform has been developed and commissioned on the Z Facility at Sandia National Laboratories in support of the Magnetized Liner Inertial Fusion (MagLIF) Program. MagLIF is a magneto-inertial fusion concept that employs a magnetically imploded metallic tube (liner) to compress and inertially confine premagnetized and preheated fusion fuel. The fuel is preheated using a ~2 kJ laser that must pass through a ~1.5-3.5-μm-thick polyimide “window” at the target’s laser entrance hole (LEH). As the terawatt-class laser interacts with the dense window, laser plasma instabilities (LPIs) can develop, which reduce the preheat energy delivered to the fuel, initiate fuel contamination, and degrade target performance. Cryogenically cooled targets increase the parameter space accessible to MagLIF target designs by allowing nearly 10 times thinner windows to be used for any accessible gas density. Thinner LEH windows reduce the deleterious effects of difficult to model LPIs. The Z Facility’s cryogenic infrastructure has been significantly altered to enable compatibility with the premagnetization and fuel preheat stages of MagLIF. The MagLIF cryostat brings the liquid helium coolant directly to the target via an electrically resistive conduit. This design maximizes cooling power while allowing rapid diffusion of the axial magnetic field supplied by external Helmholtz-like coils. A variety of techniques have been developed to mitigate the accumulation of ice from vacuum chamber contaminants on the cooled LEH window, as even a few hundred nanometers of ice would impact laser energy coupling to the fuel region. Here, the MagLIF cryostat has demonstrated compatibility with the premagnetization and preheat stages of MagLIF and the ability to cool targets to liquid deuterium temperatures in approximately 5 min.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of scatter in digital mammography from physical measurements

Purpose: That scattered radiation negatively impacts the quality of medical radiographic imaging is well known. In mammography, even slight amounts of scatter reduce the high contrast required for subtle soft-tissue imaging. In current clinical mammography, image contrast is partially improved by use of an antiscatter grid. This form of scatter rejection comes with a sizeable dose penalty related to the concomitant elimination of valuable primary radiation. Digital mammography allows the use of image processing as a method of scatter correction that might avoid effects that negatively impact primary radiation, while potentially providing more contrast improvement than is currently possible with a grid. For this approach to be feasible, a detailed characterization of the scatter is needed. Previous research has modeled scatter as a constant background that serves as a DC bias across the imaging surface. The goal of this study was to provide a more substantive data set for characterizing the spatially-variant features of scatter radiation at the image detector of modern mammography units. Methods: This data set was acquired from a model of the radiation beam as a matrix of very narrow rays or pencil beams. As each pencil beam penetrates tissue, the pencil widens in a predictable manner due to the production of scatter. The resultant spreading of the pencil beam at the detector surface can be characterized by two parameters: mean radial extent (MRE) and scatter fraction (SF). The SF and MRE were calculated from measurements obtained using the beam stop method. Two digital mammography units were utilized, and the SF and MRE were found as functions of target, filter, tube potential, phantom thickness, and presence or absence of a grid. These values were then used to generate general equations allowing the SF and MRE to be calculated for any combination of the above parameters. Results: With a grid, the SF ranged from a minimum of about 0.05 to a maximum of about 0.16, and the MRE ranged from about 3 to 13 mm. Without a grid, the SF ranged from a minimum of 0.25 to a maximum of 0.52, and the MRE ranged from about 20 to 45 mm. The SF with a grid demonstrated a mild dependence on target/filter combination and kV, whereas the SF without a grid was independent of these factors. The MRE demonstrated a complex relationship as a function of kV, with notable difference among target/filter combinations. The primary source of change in both the SF and MRE was phantom thickness. Conclusions: Because breast tissue varies spatially in physical density and elemental content, the effective thickness of breast tissue varies spatially across the imaging field, resulting in a spatially-variant scatter distribution in the imaging field. The data generated in this study can be used to characterize the scatter contribution on a point-by-point basis, for a variety of different techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-319: The Effect of Slice Thickness On IMRT Planning

Purpose: The accuracy of volume estimated of a treatment planning system is investigated in this study. In addition, the effect of slice thickness on IMRT planning is also studied. Methods: The accuracy in volume determination was investigated using a water phantom containing various objects with known volumes ranging from 1–100cm{sup 3}. The phantom was scanned with different slice thickness (1–10 mm). The CT data sets were sent to Eclipse TPS for contour delineation and volume calculation. The effect of slice thickness on IMRT planning was studied using a commercial phantom containing four different shaped objects. The phantom was scanned with different slice thickness (1–5 mm). IMRT plans were generated for the different CT datasets to calculate TCP, homogeneity (HI) and conformity indices (CI). Results: The variability of volumes with CT slice thickness was significant especially for small volume structures. The minimum and maximum error in the volume estimation is in the range of −2.3% to 92%. On the other hand, with increasing slice thickness, the PTV mean dose and TCP values decreases. Maximum variation of ∼5% was observed in mean dose and ∼2% in TCP with slice thickness change from 1–5 mm. The relative decrease in target volume receiving 95% of prescribed dose is ∼5% slice thickness change from 1–5 mm. HI increases up to 163% and CI decreases by 4% between 1–5 mm slice thickness change, producing highly inhomogeneous and least conformal plan. Conclusion: Accuracy of volume estimation is dependent on CT slice thickness and the contouring algorithm in a TPS. During TPS commissioning and for all clinical protocols, evaluation of volume should be included to provide the limit of accuracy in DVH calculation. A smaller slice thickness provides superior dosimetry with improved TCP values. Thus, the smallest possible slice thickness should be used for IMRT planning.

07 ISOTOPE AND RADIATION SOURCES↗

TU-F-BRF-09: Feasibility Study of Spatial and Temporal Fractionation Using a Table-Top Image-Guided MRT System

Purpose: Microbeam radiation therapy is a promising experimental radiotherapy method for cancer treatment. Synchrotron studies have shown that MRT can preferentially ablate tumors while mostly preserving the surrounding normal tissues. Our purpose is to develop a compact microbeam irradiator that can be accessible for laboratory research on MRT's therapeutic mechanism, with the ultimate goal of translating this technique for clinical applications. Utilizing a carbon nanotube field emission X-ray source array, our lab has developed a first of its kind table-top microbeam irradiator. The purpose of this study is to investigate the possibility of increasing the total dose to the tumor region using spatial and temporal fractionation. Methods: MRI and CT scans were acquired and registered to locate both the target region and the landmark in the treatment coordinate space. A crossbeam treatment configuration was planned to achieve the desired dosage and tumor coverage. One array of 300 μm-thick microbeams was delivered to the target on the first day. Another array, perpendicular to the first one, was delivered the next day targeting the same region. The feasibility of this image-guided MRT procedure was evaluated using a phantom. Gafchromic EBT2 film was employed to characterize the targeting accuracy and the delivered tumor dose. Results: The preliminary phantom study showed that a cross-pattern of microbeam arrays was successfully delivered with sub-millimeter targeting accuracy. The delivered dose in the target region was doubled. The fraction of tumor volume that received the peak dose was increased. Conclusion: Temporal fractionation of crosspatterned microbeams can be delivered to the same target region. The feasibility of this procedure was investigated with a phantom study. Once implemented, this procedure has the potential of increasing the tumor control effect of MRT and of achieving better normal tissue recovery.

60 APPLIED LIFE SCIENCES↗

MO-FG-303-08: PET-Detectable Bimetallic (Zn@Au) Nanoparticles for Radiotherapy and Molecular Imaging Applications

Purpose: A technical challenge in clinical translation of GNP-mediated radiotherapy is lack of in-vivo imaging tools for monitoring biodistribution of GNPs. While several modalities (x-ray fluorescence, photoacoustic, etc.) are investigated, we propose a potentially more effective technique based on PET imaging. We developed Zn@Au NPs whose Zn core acts as positron emitters when activated by protons, while the Au shell plays the original role for GNP-mediated radiosensitization. Methods: Spherical Zn NPs (∼7nm diameter) were synthesized and then coated with ∼7nm thick Au layer to make Zn@Au NPs (∼20nm diameter). A water slurry containing 29mg of Zn@Au NPs was deposited (<10µm thickness) on a thin cellulose target and subsequently baked to remove the water. The cellulose matrix was placed in an aluminum target holder and irradiated with 14.5MeV protons from a GE PETtrace cyclotron with 4µA for 5min. After irradiation the cellulose matrix with the NPs was placed in a dose calibrator to assay radioactivity. Gamma spectroscopy using a HPGe detector was conducted on a very small fraction (<1mg) of the irradiated NPs. Results: We measured 158µCi of activity 32min after end of bombardment (EOB) using 66Ga setting on the dose calibrator (contribution from the cellulose matrix is negligible) which decreased to 2µCi over a 24hrs period. A gamma spectrum started one hour after EOB on the small fraction and acquired for 700sec showed a strong peak at 511keV (∼40,000 counts) with several other peaks (highest peak <1200 counts) of smaller magnitude. Conclusion: Strong 511keV gamma emission from proton-activated Zn cores can potentially be utilized to image the biodistribution of Zn@Au NPs using a PET scanner. The developed Zn@Au NPs are expected to retain radiosensitizing capability similar to solid GNPs, while observable through PET imaging for human-sized objects. Moreover, bioconjugated PET-detectable GNPs would allow a new option to perform molecular imaging.

60 APPLIED LIFE SCIENCES↗

Development of bimetallic (Zn@Au) nanoparticles as potential PET-imageable radiosensitizers

Purpose: Gold nanoparticles (GNPs) are being investigated actively for various applications in cancer diagnosis and therapy. As an effort to improve the imaging of GNPs in vivo, the authors developed bimetallic hybrid Zn@Au NPs with zinc cores and gold shells, aiming to render them in vivo visibility through positron emission tomography (PET) after the proton activation of the zinc core as well as capability to induce radiosensitization through the secondary electrons produced from the gold shell when irradiated by various radiation sources. Methods: Nearly spherical zinc NPs (∼5-nm diameter) were synthesized and then coated with a ∼4.25-nm gold layer to make Zn@Au NPs (∼13.5-nm total diameter). 28.6 mg of these Zn@Au NPs was deposited (∼100 μm thick) on a thin cellulose target and placed in an aluminum target holder and subsequently irradiated with 14.15-MeV protons from a GE PETtrace cyclotron with 5-μA current for 5 min. After irradiation, the cellulose matrix with the NPs was placed in a dose calibrator to assess the induced radioactivity. The same procedure was repeated with 8-MeV protons. Gamma ray spectroscopy using an high-purity germanium detector was conducted on a very small fraction (<1 mg) of the irradiated NPs for each proton energy. In addition to experimental measurements, Monte Carlo simulations were also performed with radioactive Zn@Au NPs and solid GNPs of the same size irradiated with 160-MeV protons and 250-kVp x-rays. Results: The authors measured 168 μCi of activity 32 min after the end of bombardment for the 14.15-MeV proton energy sample using the {sup 66}Ga setting on a dose calibrator; activity decreased to 2 μCi over a 24-h period. For the 8-MeV proton energy sample, PET imaging was additionally performed for 5 min after a 12-h delay. A 12-h gamma ray spectrum showed strong peaks at 511 keV (2.05 × 10{sup 6} counts) with several other peaks of smaller magnitude for each proton energy sample. PET imaging showed strong PET signals from mostly decaying {sup 66}Ga. The Monte Carlo results showed that radioactive Zn@Au NPs and solid GNPs provided similar characteristics in terms of their secondary electron spectra when irradiated. Conclusions: The Zn@Au NPs developed in this investigation have the potential to be used as PET-imageable radiosensitizers for radiotherapy applications as well as PET tracers for molecular imaging applications.

60 APPLIED LIFE SCIENCES↗

Observations of Shock-Loaded Tin and Zirconium Surfaces with Single-Pulse X-ray Diffraction

A single-pulse X-ray diffraction (XRD) diagnostic has been developed for the investigation of shocked material properties on a very short time scale. The diagnostic, which consists of a 37-stage Marx bank high-voltage pulse generator coupled to a needle-and-washer electron beam diode via coaxial cable, produces line-and-bremsstrahlung X-ray emission in a 40 ns pulse. The molybdenum anode produces 0.71 Å characteristic K lines used for diffraction. The X-ray beam passes through a pinhole collimator and is incident on the sample with an approximately 2 mm×5 mm spot and 1° full width at half maximum angular divergence. Coherent scattering from the sample produces a Debye-Scherrer diffraction pattern on an image plate located at 75 mm from the polycrystalline sample surface. An experimental study of the polycrystalline structures of zirconium and tin under high-pressure shock loading has been conducted with single-pulse XRD. The experimental targets were 0.1-mm-thick foils of zirconium and tin using 0.4-mm-thick vitreous carbon back windows for shock loading, and the shocks were produced by either Detasheet or PBX-9501 high explosives buffered by 1-mm-thick 6061-T6 aluminum. The diffraction patterns from both shocked zirconium and tin indicated a phase transition into a polymorphic mix of amorphous and new solid phases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗