Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Improvements to the Photometric response and positional accuracy of the Yale PDS 2020G microdensitometer

The necessity to incorporate several hardware changes to optimize the Yale PDS 2020G microdensitometer for photometric and astrometric research are discussed. The properties of a new high speed photometer and a positional calibration system are described. The new photometer incorporates a high speed logarithmic analog to digital converter with more than 10 times the resolution of the former system and a cycle time of approximately 50 usec. The positional calibration system monitors the drunkenness of the stages with respect to fixed index lines and enables the correction of the +/- 5 micro stage errors to an accuracy of better than 1 micro.

Lee, J. F.↗

Advances in the RXTE Proportional Counter Array Calibration: Nearing the Statistical Limit

During its 16 years of service Rossi X-ray Timing Explorer (RXTE) mission has provided an extensive archive of data, which will serve as a primary source of high cadence observation of variable X-ray sources for fast timing studies. It is, therefore, very important to have the most reliable calibration of RXTE instruments. The Proportional Counter Array (PCA) is the primary instrument on-board RXTE which provides data in 2-50 keY with higher than millisecond time resolution in up to 256 energy channels. In 2009 RXTE team revised the response residual minimization method used to derive the parameters of the PCA physical model. The procedure is now based on the residual minimization between the model spectrum for Crab nebula emission and a calibration data set consisting of a number of spectra from the Crab and the on-board Am241 calibration source, uniformly covering a whole RXTE span. The new method led to a much more effective model convergence and allowed for better understanding of the behavior of the PCA energy-to-channel relationship. It greatly improved the response matrix performance. We describe the new version of the RXTE/PCA response generator PCARMF vll.7 along with the corresponding energy-to-channel conversion table (version e05v04) and their difference from the previous releases of PCA calibration. The new PCA response adequately represents the spectrum of the calibration sources and successfully predicts the energy of the narrow iron emission line in Cas-A throughout the RXTE mission.

Shaposhnikov, Nikolai↗

μ⋆ masses: weak-lensing calibration of the Dark Energy Survey Year 1 redMaPPer clusters using stellar masses

ABSTRACT We present the weak-lensing mass calibration of the stellar-mass-based μ⋆ mass proxy for redMaPPer galaxy clusters in the Dark Energy Survey Year 1. For the first time, we are able to perform a calibration of μ⋆ at high redshifts, z > 0.33. In a blinded analysis, we use ∼6000 clusters split into 12 subsets spanning the ranges 0.1 ≤ z < 0.65 and μ⋆ up to ${\sim} 5.5 \times 10^{13} \, \mathrm{M}_{\odot }$, and infer the average masses of these subsets through modelling of their stacked weak-lensing signal. In our model, we account for the following sources of systematic uncertainty: shear measurement and photometric redshift errors, miscentring, cluster-member contamination of the source sample, deviations from the Navarro–Frenk–White halo profile, halo triaxiality, and projection effects. We use the inferred masses to estimate the joint mass–μ⋆–z scaling relation given by $\langle M_{200c} | \mu _{\star },z \rangle = M_0 (\mu _{\star }/5.16\times 10^{12} \, \mathrm{M_{\odot }})^{F_{\mu _{\star }}} ((1+z)/1.35)^{G_z}$. We find $M_0= (1.14 \pm 0.07) \times 10^{14} \, \mathrm{M_{\odot }}$ with $F_{\mu _{\star }}= 0.76 \pm 0.06$ and Gz = −1.14 ± 0.37. We discuss the use of μ⋆ as a complementary mass proxy to the well-studied richness λ for: (i) exploring the regimes of low z, λ < 20 and high λ, z ∼ 1; and (ii) testing systematics such as projection effects for applications in cluster cosmology.

79 ASTRONOMY AND ASTROPHYSICS↗

A space system for high-accuracy global time and frequency comparison of clocks

A Space Shuttle experiment in which a hydrogen maser clock on board the Space Shuttle will be compared with clocks on the ground using two-way microwave and short pulse laser signals is described. The accuracy goal for the experiment is 1 nsec or better for the time transfer and 10 to the minus 14th power for the frequency comparison. A direct frequency comparison of primary standards at the 10 to the minus 14th power accuracy level is a unique feature of the proposed system. Both time and frequency transfer will be accomplished by microwave transmission, while the laser signals provide calibration of the system as well as subnanosecond time transfer.

Decher, R.↗

Implementing Best Practices for Data Quality Assessment of the National Renewable Energy Laboratory's Solar Resource and Meteorological Assessment Project

Effective solar radiation measurements for research and economic analyses require a strict protocol for maintenance, calibration, and documentation to minimize station down-time and data corruption. The National Renewable Energy Laboratory's Concentrating Solar Power: Best Practices Handbook for the Collection and Use of Solar Resource Data (1) includes guidelines for operating a solar measure-ment station. This paper describes a suite of automated and semi-automated routines based on the best practices hand-book as developed for the National Renewable Energy La-boratory Solar Resource and Meteorological Assessment Project. These routines allow efficient inspection and data flagging to alert operators of conditions that require imme-diate attention. Although the handbook is targeted for con-centrating solar power applications, the quality-assessment procedures described are generic and should benefit many solar measurement applications. The routines use data in one-minute measurement resolution, as suggested by the handbook, but they could be modified for other time scales.

14 SOLAR ENERGY↗

Absolute calibration for SAR systems

Absolute calibration of synthetic aperture radar data is desirable for space and time continuity in earth resource investigations. For this purpose, a calibration signal is used to compare data from a calibration flight, during which precision reflectors are imaged, to data from subsequent SAR flights. The calibration signal duplicates the SAR response from a point source. This signal is amplified and converted by the radar system and processed in precisely the same way as data.

Jackson, P. L.↗

Reducing Uncertainties in Model Predictions via History Matching of CO 2 Migration and Reactive Transport Modeling of CO 2 Fate at the Sleipner Project

An important question for the Carbon Capture, Storage, and Utility program is “can we adequately predict the CO 2 plume migration?” For tracking CO 2 plume development, the Sleipner project in the Norwegian North Sea provides more time-lapse seismic monitoring data than any other sites, but significant uncertainties still exist for some of the reservoir parameters. In Part I, we assessed model uncertainties by applying two multi-phase compositional simulators to the Sleipner Benchmark model for the uppermost layer (Layer 9) of the Utsira Sand and calibrated our model against the time-lapsed seismic monitoring data for the site from 1999 to 2010. Approximate match with the observed plume was achieved by introducing lateral permeability anisotropy, adding CH 4 into the CO 2 stream, and adjusting the reservoir temperatures. Model-predicted gas saturation, CO 2 accumulation thickness, and CO 2 solubility in brine—none were used as calibration metrics—were all comparable with the interpretations of the seismic data in the literature.

20 FOSSIL-FUELED POWER PLANTS↗

On-line calibration of high-response pressure transducers during jet-engine testing

Current jet engine testing is concerned with the effect of inlet pressure and temperature distortions on engine performance and involves the use of numerous miniature pressure transducers. Despite recent improvements in the manufacture of miniature pressure transducers, they still exhibit sensitivity change and zero shift with temperature and time. To obtain meaningful data, a calibration system is needed to determine these changes. A system has been developed which provides for computer selection of appropriate reference pressures selected from nine different sources to provide a two- or three-point calibration. Calibrations are made on command, before and sometimes after each data point. A unique 'no leak' matrix valve design is used in the reference-pressure system. Zero-shift corrections are measured and the values are automatically inserted into the data reduction program.

Armentrout, E. C.↗

On-line calibration of high-response pressure transducers during jet-engine testing

Jet engine testing is reported concerned with the effect of inlet pressure and temperature distortions on engine performance and involves the use of numerous miniature pressure transducers. Despite recent improvements in the manufacture of miniature pressure transducers, they still exhibit sensitivity change and zero-shift with temperature and time. To obtain meaningful data, a calibration system is needed to determine these changes. A system has been developed which provides for computer selection of appropriate reference pressures selected from nine different sources to provide a two- or three-point calibration. Calibrations are made on command, before and sometimes after each data point. A unique no leak matrix valve design is used in the reference pressure system. Zero-shift corrections are measured and the values are automatically inserted into the data reduction program.

Armentrout, E. C.↗

Magsat vector magnetometer calibration using Magsat geomagnetic field measurements

From the time of its launch on Oct. 30, 1979 into a nearly polar, Sun synchronous orbit, until it reentered the Earth's atmosphere on June 11, 1980, Magsat measured and transmitted more than three complete sets of global magnetic field data. The data obtained from the mission will be used primarily to compute a currently accurate model of the Earth's main magnetic field, to update and refine world and regional magnetic charts, and to develop a global scalar and vector crustal magnetic anomaly map. The in-flight calibration procecure used for 39 vector magnetometer system parameters is described as well as results obtained from some data sets and the numerical studies designed to evaluate the results.

Lancaster, E. R.↗

ADVANCES IN THE RXTE PROPORTIONAL COUNTER ARRAY CALIBRATION: NEARING THE STATISTICAL LIMIT

During its 16 years of service, the Rossi X-Ray Timing Explorer (RXTE) mission has provided an extensive archive of data, which will serve as a primary source of high cadence observations of variable X-ray sources for fast timing studies. It is, therefore, very important to have the most reliable calibration of RXTE instruments. The Proportional Counter Array (PCA) is the primary instrument on board RXTE which provides data in 3-50 keV energy range with submillisecond time resolution in up to 256 energy channels. In 2009, the RXTE team revised the response residual minimization method used to derive the parameters of the PCA physical model. The procedure is based on the residual minimization between the model spectrum for Crab Nebula emission and a calibration data set consisting of a number of spectra from the Crab and the on-board Am{sub 241} calibration source, uniformly covering the whole RXTE mission operation period. The new method led to a much more effective model convergence and allowed for better understanding of the PCA energy-to-channel relationship. It greatly improved the response matrix performance. We describe the new version of the RXTE/PCA response generator PCARMF v11.7 (HEASOFT Release 6.7) along with the corresponding energy-to-channel conversion table (version e05v04) and their difference from the previous releases of PCA calibration. The new PCA response adequately represents the spectrum of the calibration sources and successfully predicts the energy of the narrow iron emission line in Cas-A throughout the RXTE mission.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial On-Orbit Spectral Calibration of the PACE Ocean Color Instrument

The NASA Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission Project Science Team has used Ocean Color Instrument (OCI) measurements of Fraunhofer lines in spectra of sunlight reflected by the solar diffuser and measurements of atmospheric absorption bands in cloudtop and ocean spectra to characterize the spectral calibration of OCI on orbit. Multiple lines have been analyzed for both the ultraviolet to visible (UVVIS, 340−607 nm) and visible to near-infrared (VISNIR, 597−897 nm) grating spectrographs. The spectrographs yield hyperspectral observations with 5 nm bandwidths and 0.625 nm sampling intervals. The on-orbit observations have been compared with the prelaunch spectral calibration of OCI performed by the Goddard Laser for Absolute Measurement of Radiance (GLAMR) during thermal vacuum testing to track any changes in the calibration since launch. The calibration analyzed the line positions and strengths for the Fraunhofer lines for each spectrograph by comparing the solar spectra measured by OCI with predicted solar spectra derived from the solar reference spectrum and the BRDF of the solar diffuser, convolved with the OCI relative spectral responses. The calibration also compared the line positions of the atmospheric absorption bands with the model transmissions used by the PACE Project. The line position comparisons show that the root mean square (RMS) spectral difference between the measured and predicted spectra is 0.15 nm, the average spectral shift is 0.062 nm, and the residual spectral dispersion over the wavelength range of the Fraunhofer lines is 0.17 nm. All three estimates of the spectral accuracy of OCI meet the instrument functional requirement of a spectral accuracy of 0.5 nm and are well within the 0.625 nm sampling interval of the data. The line strength comparisons between measured and predicted spectra are essentially the same. These results show that the spectral calibration of OCI on orbit has not drifted since the prelaunch calibration of OCI by GLAMR and that the on-orbit spectral calibration of OCI is stable over time. These results also provide a baseline for monitoring the future spectral performance of OCI on orbit.

Radiometric Calibration↗

SBND Calibration

The Short-Baseline Near Detector (SBND) is a 112-ton liquid argon time projection chamber (LArTPC) serving as the near detector of the Short-Baseline Neutrino Program at Fermilab. SBND aims to make precise measurements of neutrino-argon interactions, necessitating an extensive calibration program for the LArTPC to ensure precision/accuracy in these measurements. This talk describes the use of cosmogenic, radiogenic, and neutrino interaction activity with both Monte Carlo simulation and data in calibrating the SBND subsystems of the Time Projection Chamber, Photon Detection System, and Cosmic Ray Tagger. We will highlight some of SBND's first calibration results, including electronics calibrations, measurement of the electron lifetime, shower calibration, and studies of space charge effects in the detector.

Oh, Sungbin [Fermilab]↗

Development of prechamber enabled mixing-controlled combustion strategy for ultra-low methane emissions from lean burn natural gas engines

This numerical study explores the optimization of Prechamber Enabled Mixing-Controlled Combustion (PC-MCC) using natural gas in heavy-duty engines, aiming to enhance combustion efficiency to minimize methane slip and NOx emissions. The approach involves a prechamber ignition system, distinct from conventional spark ignition (SI) systems, to initiate combustion of direct injected natural gas. By leveraging the robust ignition characteristics of the prechamber, the PC-MCC method demonstrates significant potential in achieving efficient combustion akin to diesel engines but with lower greenhouse gas emissions. The research evaluates the effects of various geometric and operational parameters on the combustion process and emissions, including prechamber volume, nozzle diameter, direct injector (DI) geometry, and engine operating strategies. Computational Fluid Dynamics (CFD) simulations are utilized, focusing on a heavy-duty, single-cylinder engine modeled after the Caterpillar C9.3B engine. Key findings indicate that a prechamber volume of 3 cc, coupled with a nozzle diameter of 2.75 mm for two prechamber holes, strikes an optimal balance between combustion efficiency and emissions reduction. This configuration ensures robust combustion across a range of operating conditions while maintaining methane slip within targeted limits. Further investigation into DI geometry shows the significance of the injector umbrella angle and nozzle diameter in shaping the fuel-air mixing and combustion dynamics. An umbrella angle of 130° and a nozzle diameter of 300 microns are identified as optimal, promoting rapid and efficient combustion with minimized methane and NOx emissions. The study also investigates the impact of injection timing and pressure, highlighting their roles in controlling combustion timing and influencing emissions levels. Advanced injection timing is found to be crucial in achieving the desired low methane slip, whereas retarded injection timing assists to reduce NOx emissions while having a slight increase in methane emissions. Operating strategies incorporating various levels of Exhaust Gas Recirculation (EGR) are assessed for their effectiveness in further reducing emissions. The research demonstrates that a judicious combination of internal hot EGR and careful calibration of DI pressure and SOI timing can achieve significant reductions in NOx emissions while keeping methane slip under control. Specifically, an internal EGR level of 15%–25%, combined with DI pressures of 200–300 bar and injection timings at or after top dead center, is recommended. These findings contribute valuable insights into the development of advanced combustion techniques for natural gas engines, offering a viable pathway to reduce methane slip without compromising engine efficiency or performance. The PC-MCC system presents a promising solution for the future of heavy-duty natural gas engine technology to reduce methane emissions.

Nsaif, Osama↗

Calibration Refinements in Support of MISR

The Multi-angle Imaging SpectroRadiometer (MISR) is one of five instruments on-board the EOSI Terra spacecraft, and has collected science data since March 2000. A multi-angle capability is provided by ninecameras, which view up to 70' forward and aft of the spacecraft track and enable unique geophysical retrievals. Throughout its mission, a calibration team has made periodic refinements to the process used to calibrate MISR. These have resulted in improved absolute, and band and camera-relative calibrations, as well as in derived geophysical data products. Data reprocessing is on-going, such that these refinements also improve previous data acquisitions. The calibration process is believed to be mature at this time, with no other changes anticipated. Bimonthly deployments of the on-board-calibrator continue to monitor instrument response degradations, and provide correction coefficients needed to maintain the accuracy of the radiance products.

refinements↗

R-values

I'll try to keep this short and simple. R{sub LANL} = (beta cpm of X{sub exp} on system 'A')/ (beta cpm of {sup 99}Mo{sub exp} on system 'A')/ (beta cpm of X on system 'A', from thermal on {sup 235}U)/ (beta cpm of {sup 99}Mo on system 'A', from thermal on {sup 235}U). As I understand it, the above equation is the historical (as well as current) way of determining R-values using data from beta counting at LANL. The ratio in the denominator, a little 'r', is the 'baseline' or 'calibration' value for a specific beta detector. Over time, if the detector 'drifts' one would see a variation in this 'r' during a thermal calibration measurement. This baseline is what LANL likes to track to monitor specific detector performance - this is not relevant to LLNL where gamma detection is used for determining R-values. LANL states that uncertainty is only dependent upon the count statistics for the isotopes measured. If one tries to convert this to an atom basis, the uncertainties will increase due to the incorporation of the uncertainties in the nuclear data used to convert the cpm to atoms. LLNL switched to gamma detection methods in the 1970s thus replacing our beta counting effort. The equation below is how we have since determined R-values. The numerator ratios atom values of isotopes that are determined by measuring gamma cpm (usually? using several peaks per isotope) and then converting to particle decay in dpm using detector efficiency for each peak and the appropriate branch ratio for each gamma emission. Isotope decay is then converted to atoms using specific activity, mass or volume?, and Avogadro's number. The denominator is simply the ratio of published, cumulative fission product chain yields for isotopes produced in a thermal irradiation on 235U - values of England & Ryder are used by LLNL for the NTNF program. Uncertainties in LLNL R-values are dependent upon gamma counting statistics as well as the nuclear data for each isotope. R{sub LLNL} = (Atoms of X{sub exp})/(Atoms of {sup 99}Mo{sub exp})/(Cumulative Fission Chain Yield of X, from thermal on {sup 235}U)/(Cumulative Fission Chain Yield of {sup 99}Mo, from thermal on {sup 235}U). The next page tabulates fission chain yields and 'atoms per gram' amounts measured in a recent NTNF Thermal Calibration. The R-values in the table are calculated using the LLNL method of determining R. The measure of success is demonstrated by how close to 1.00 the R-value is when determined during a Thermal Calibration. A value of 1.00 is the desired value. In the example below, only four isotopes lie outside of 1.00 by more than 3 percent. These are the four isotopic measurements that obviously need to be improved.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Advanced solid-state array spectroradiometer data collection during HAPEX-2 Sahel

Data collection using the Advanced Solid-state Array Spectroradiometer (ASAS) during the Hydrologic Atmospheric Pilot Experiment in the Sahel (HAPEX-II Sahel) field campaign in the Republic of Niger, West Central Africa from 22 Aug. to 19 Sep. 1992 is documented. Details on the ASAS system such as the hardware, data collection methods, information on system calibration, and data processing procedures are included. The ASAS configuration deployed for HAPEX-II Sahel contains several new components, including a new sensor array and pointing system. Because of this, new calibration procedures are being developed at the same time that the first ASAS images from HAPEX-II Sahel are being processed. These new calibration procedures will be documented in a future publication.

Walthall, Charles L.↗

Precision Determination of Atmospheric Extinction at Optical and Near IR Wavelengths

The science goals for future ground-based all-sky surveys, such as the Dark Energy Survey, PanSTARRS, and the Large Synoptic Survey Telescope, require calibration of broadband photometry that is stable in time and uniform over the sky to precisions of a per cent or better, and absolute calibration of color measurements that are similarly accurate. This performance will need to be achieved with measurements made from multiple images taken over the course of many years, and these surveys will observe in less than ideal conditions. This paper describes a technique to implement a new strategy to directly measure variations of atmospheric transmittance at optical wavelengths and application of these measurements to calibration of ground-based observations. This strategy makes use of measurements of the spectra of a small catalog of bright 'probe' stars as they progress across the sky and back-light the atmosphere. The signatures of optical absorption by different atmospheric constituents are recognized in these spectra by their characteristic dependences on wavelength and airmass. State-of-the-art models of atmospheric radiation transport and modern codes are used to accurately compute atmospheric extinction over a wide range of observing conditions. We present results of an observing campaign that demonstrate that correction for extinction due to molecular constituents and aerosols can be done with precisions of a few millimagnitudes with this technique.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗