Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time resolved imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

REVEALING COMPANIONS TO NEARBY STARS WITH ASTROMETRIC ACCELERATION

A subset of 51 Hipparcos astrometric binaries among FG dwarfs within 67 pc has been surveyed with the Near-Infrared Coronagraphic Imager adaptive optics system at Gemini-S, directly resolving for the first time 17 subarcsecond companions and 7 wider ones. Using these data together with published speckle interferometry of 57 stars, we compare the statistics of resolved astrometric companions with those of a simulated binary population. The fraction of resolved companions is slightly lower than expected from binary statistics. About 10% of astrometric companions could be 'dark' (white dwarfs and close pairs of late M-dwarfs). To our surprise, several binaries are found with companions too wide to explain the acceleration. Re-analysis of selected intermediate astrometric data shows that some acceleration solutions in the original Hipparcos catalog are spurious.

79 ASTRONOMY AND ASTROPHYSICS↗

The Hybrid X-Pinch as a Source of XUV Radiation

The first detailed study of hybrid X-pinch (HXP) radiation in the wavelength range 10–200 Å on the BIN pulser (270 kA, 100 ns rise time) is introduced here. X-pinch loads were made from Al, Mo, Ag, and W wires with 13–30 μm diameters. Time-integrated images were obtained using open pinholes with 100 μm aperture. Spatially resolved XUV spectra were recorded using a transmission grating spectrograph on UF-4 film and with Fuji TR image plates. Signals from calibrated photoconducting detectors enabled estimates of the absolute yield of radiation and demonstrated that Mo HXPs radiate about 100× more energy in UV radiation than in X-rays with energy above 1 keV.

Hot spot (HS)↗

From 3rd- to 4th-generation light sources: Free-electron lasers in the X-ray range

Activities on free-electron laser (FEL) x-ray sources, based on linear accelerators, to produce spatially coherent, ultra-short ({approx}100 fs) pulses with very high peak brilliance (10{sup 28}-10{sup 32} photons/s/mm{sup 2}/mrad{sup 2}/0.1% BW) are summarized. The scientific case includes time-resolved studies of dynamics on sub-ps scales, structural studies by imaging of non-periodic systems, and investigation of high energy-density phenomena such as non-linear x-ray optics and the production of warm dense matter. Examples are presented, with emphasis on the operational facilities, FLASH at DESY, Hamburg and LCLS in Stanford, California, and on the European XFEL project in Hamburg.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Shock-Driven Hydrodynamic Instability Growth Near Phase Boundaries and Material Property Transitions: Final Report

Activities for this grant included: 1) Development of dynamic impact experiments to probe strength and phase transition influence on dynamic deformation, 2) development of modern strength and phase aware simulation capabilities, 3) and post-processing of experimental data with simulation and closed form analytical techniques. Two different dynamic experiments were developed to probe material strengths in solid metals (largely copper and iron in this effort). In the first experiment a flyer plate impacts a flat target with an opposite rippled surface that is partially supported by a weaker window material. Post mortem analysis of the target sample showed a strong and repeatable residual plastic deformation dependence on grain orientation. Yield strengths for strain rates near 10 5 s -1 and plastic strains near ~50% were estimated to be around 180 to 240 MPa, varying in this range with grain orientation. Unfortunately dynamic real-time measurements were difficult with this setup due to diagnostic laser scattering; hence, an additional experimental setup was developed to complement these results. In the second set of experiments a rippled surface was ablated by a controlled laser pulsed, which launched a rippled shock front to an opposite initially flat diagnostic surface that was monitored in real-time with spatially resolved velocimetry techniques, e.g., line VISAR in addition to Transient Imaging Displacement Interferometry (TIDI) displacement measurements. This setup limited the displacements at the diagnostic surface to a reasonable level for TIDI measurements (~ less than one micrometer). These experiments coupled with analytical and numerical solutions provided evidence that viscous and elastic deviatoric strength affect shock front perturbation evolution in clearly different ways. Particularly, normalized shock front perturbation amplitudes evolve with viscosity (η) and perturbation wavelength (λ) as η/λ, such that increasing viscosity (or decreasing the initial wavelength) delays the perturbation decay. Conversely our experimental data, analysis and simulations show that for materials with elastic yield strength Y the normalized shock perturbation amplitude evolves with Yλ/A 0 , which shows wavelength increases have the opposite effect as in viscous materials and perturbation decay is also dependent on initial amplitude A 0 (viscous materials are independent of this parameter). Materials where strength had clear strain rate dependence, e.g., such as a PTW material law, behaved similarly to materials with only an effective yield stress (elastic-perfectly plastic) in the shock front perturbation studies obeying a Y eff λA 0 relationship where Y eff was a constant (near ~400 MPa for Cu for strain rates around 10 6 s -1 ). Magnitude changes in strain rate would increase Y eff as would be expected from the PTW behavior, but small perturbations (typical of regions behind the shock front) near a mean had little effect. Additional work based on simulations showed that phase transformation kinetics can affect the behavior of the perturbed shock front as well as the evolution of the RM-like instability that develops due to the imprint of the perturbed shock front on the initially flat surface as the shock breaks out.

36 MATERIALS SCIENCE↗

NucD-24 Nuclear Diagnostics Development: Time resolved 12 C-rhoR on GCD and NIS technology development for polar LOS and data quality [Slides]

The Neutron Imaging team is readying for the NIS2 polar LOS development and future improvements to data quality on all LOS given consistently higher yields at NIF. Next-gen nano guide scintillators for NIS2 and CMOS cameras to replace outdated CCDs will be studied. Digital image plates will be tested for better data quality on passive imaging systems. The transition into the ignition regime is expected to show a significant signature in the ablator areal density. In the marginal ignition regime, a decrease of 12C-rhoR (ablator areal density) is expected but once the burn propagation produces a shock and compresses the ablator the trend reverses. GCD with the PD-PMT can resolve this effect in the ablator areal density by a temporal shift in the carbon signal. To give quantitative results a calibration of the detector for the Hohlraum/TMP signal is needed. Shots using Al, Si, and Au pucks will yield the needed information to move forward with this project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In Situ Synchrotron Micro-CT of Microballoon-Filled RTV Silicone During Thermal Decomposition

This work investigates the thermal decomposition of microballoon-filled room-temperature-vulcanizing (RTV) silicone using time-resolved synchrotron micro-CT at the Advanced Light Source. In situ imaging of constrained and unconstrained samples captures the evolution of the internal microstructure during heating, including material expansion, microballoon and void growth, tearing, pyrolysis, shrinkage, and increasing porosity. The measurements provide new insight into the mechanisms governing RTV degradation and generate three-dimensional data for future quantitative analysis and material-response model development.

TPS↗

In-Situ Photostability Analysis of Perovskite Solar Cells by Time-Evolving Photoluminescence Imaging

In this work we investigate reversible metastabilities and irreversible degradation due to light soaking of triple-cation mixed-halide perovskite p-i-n solar cells. We use spatially resolved luminescence imaging to document the spatial inhomogeneities that exist even in high-performance devices with median efficiencies >20%. We monitor light-soaking degradation in-situ using time-evolving photoluminescence images, electro-luminescence images, and transient photovoltage. Post-stress measurements of external quantum efficiency and Kelvin- probe force microscopy suggest that long-term degradation primarily affects electrode interfaces rather than the absorber layer.

electroluminescence↗

Strictly Enforcing Invertibility and Conservation in CNN-Based Super Resolution for Scientific Datasets

Abstract Recently, deep convolutional neural networks (CNNs) have revolutionized image “super resolution” (SR), dramatically outperforming past methods for enhancing image resolution. They could be a boon for the many scientific fields that involve imaging or any regularly gridded datasets: satellite remote sensing, radar meteorology, medical imaging, numerical modeling, and so on. Unfortunately, while SR-CNNs produce visually compelling results, they do not necessarily conserve physical quantities between their low-resolution inputs and high-resolution outputs when applied to scientific datasets. Here, a method for “downsampling enforcement” in SR-CNNs is proposed. A differentiable operator is derived that, when applied as the final transfer function of a CNN, ensures the high-resolution outputs exactly reproduce the low-resolution inputs under 2D-average downsampling while improving performance of the SR schemes. The method is demonstrated across seven modern CNN-based SR schemes on several benchmark image datasets, and applications to weather radar, satellite imager, and climate model data are shown. The approach improves training time and performance while ensuring physical consistency between the super-resolved and low-resolution data. Significance Statement Recent advancements in using deep learning to increase the resolution of images have substantial potential across the many scientific fields that use images and image-like data. Most image super-resolution research has focused on the visual quality of outputs, however, and is not necessarily well suited for use with scientific data where known physics constraints may need to be enforced. Here, we introduce a method to modify existing deep neural network architectures so that they strictly conserve physical quantities in the input field when “super resolving” scientific data and find that the method can improve performance across a wide range of datasets and neural networks. Integration of known physics and adherence to established physical constraints into deep neural networks will be a critical step before their potential can be fully realized in the physical sciences.

54 ENVIRONMENTAL SCIENCES↗

The Physics of Gain Mechanisms in a Self-Amplified Spontaneous Emission Free-Electron Laser

This is the final report for the DoE BES contract DE-FG02-07ER46272. This grant began under a title that gives its history in a few words: The Physics of Gain Mechanisms in a Self-Amplified Spontaneous Emission Free-Electron Laser. At the time of adopting this name, the UCLA Particle Beam Physics Laboratory (PBPL) was at the forefront of the first demonstrations of SASE FEL, giving the experimental basis for the 4th generation X-ray light source now exemplified by the LCLS, a remarkable generation of machines that have revolutionize nanoscale and ultrafast science. The grant title indicates that physical aspects of the FEL are of interest, and implies that progress requires comprehensive investigations. These aspects include: the physics and technology of high brightness electron beam generation, phase space manipulations, advanced beam diagnostics, state-of-the-art undulators, studies of FEL mode characteristics, as well as the introduction of new theoretical models and start-to-end simulations, all yielding a deep understanding of the SASE FEL. The latest period (2010-13) of BES grant support has been the most productive yet for the UCLA PBPL, and the extensive list of accomplishments is illustrative of our central contributions to advanced FEL research. We give a concise overview here and review our research results in further detail below. In FEL and ultrafast beam physics, we have experimentally investigated: production of helical beams and FEL modes with orbital angular momentum; chirp-taper single-spike FEL gain; new FROG techniques optimized for FEL, introduced coherent imaging of beam profiles using transition radiation; and demonstrated a next generation cryoundulator. We have performed deep theoretical studies of these phenomena and other advanced FEL physics concepts, such as the space-charge amplifier. In high brightness beams, we have: introduced a new class of hybrid photoinjector for <100 fs beam production; developed new approaches to self-shaped ellipsoidal beams; used nonlinear plasma oscillations to create beam pulse trains; tested new plasmonic, high quantum efficiency cathodes, and developed new methods of beam measurement with um spatial/sub-fs temporal resolution. In ultrafast imaging, we have: developed advanced electro-optic timing systems, performed the 1st pump-probe study using single shot UED, demonstrated continuously time-resolved UED with RF deflection; made initial use of inverse Compton scattering (ICS) X-ray sources in application through single-shot inline phase contrast imaging, established single-shot X-ray diffraction, and observed ICS high harmonic generation and redshifting due to nonlinear effects. In 5th generation light source research, we have developed the techniques of narrowband, very high power coherent Cerenkov radiation sources based on dielectric wakefield devices. This work is represented by numerous publications in leading journals: e.g. Nature Physics, Physical Review Letters, Applied Physics Letters. The PBPL program’s influence on the field also extends to organization of the electron beam applications community; we have organized the first international UED workshops and the initial two meetings dedicated to 5th generation light source.

43 PARTICLE ACCELERATORS↗

A multi-cone x-ray imaging Bragg crystal spectrometer

This article describes a new x-ray imaging Bragg crystal spectrometer, which—in combination with a streak camera or a gated strip detector—can be used for time-resolved measurements of x-ray line spectra at the National Ignition Facility and other high power laser facilities. The main advantage of this instrument is that it produces perfect images of a point source for each wavelength in a selectable spectral range and that the detector plane can be perpendicular to the crystal surface or inclined by an arbitrary angle with respect to the crystal surface. Furthermore, these unique imaging properties are obtained by bending the x-ray diffracting crystal into a certain shape, which is generated by arranging multiple cones with different aperture angles on a common nodal line.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser ablated zirconium plasma: A source of neutral zirconium

The authors report spectroscopic investigations of laser produced zirconium (Zr) plasma at moderate laser fluence. At low laser fluence the neutral zirconium species are observed to dominate over the higher species of zirconium. Laser induced fluorescence technique is used to study the velocity distribution of ground state neutral zirconium species. Two-dimensional time-resolved density distributions of ground state zirconium is mapped using planner laser induced fluorescence imaging and total ablated mass of neutral zirconium atoms is estimated. Temporal and spatial evolutions of electron density and temperature are discussed by measuring Stark broadened profile and ratio of intensity of emission lines, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Imaging Three-Dimensional Molecular Structure and Dynamics with Multiparticle Covariance and Cumulant Coulomb Explosion Analysis

Coulomb explosion imaging (CEI) provides a direct means of imaging molecular geometry by correlating fragment ion momenta following the fragmentation of a molecular polycation. Here, we demonstrate the use of three-body covariance and four-body cumulant analysis to extract three-dimensional (3D) structural information from the X-ray-induced Coulomb explosion of tert-butyl iodide (C4H9I). Site-selective ionization at the iodine 4d edge with intense femtosecond soft X-ray pulses from an X-ray free-electron laser (XFEL) enables rapid charge buildup and molecular breakup. By correlating ionic fragments in the molecular frame, we isolate complete dissociation channels and reveal subtle structural changes, such as umbrella-type motion of the branched alkyl chain, during the ionization process. Comparison with point-charge simulations of the Coulomb explosion shows close agreement, validating the approach. Furthermore, these results establish covariance/cumulant mapping as a powerful strategy for imaging complex three-dimensional molecular structures and point the way toward time-resolved CEI using both XFEL and tabletop sources for capturing ultrafast structural dynamics.

Imaging↗

Space and time resolved emission of hard X-rays from a plasma focus

The X-ray emission from focused plasmas was observed with an image converter camera in the streak and framing modes. Use of a very high gain image intensifier enabled weak hard X-ray emission (above 25 keV) to be recorded. The use of an admixture of higher atomic number into the deuterium was avoided, and the role of the vapor from the anode surface could be discerned. The recorded bremsstrahlung emission seemed to be from a metallic plasma of copper released from the anode surface by bombardment from an intense electron beam. The intensity of emission was determined by the density of copper and the density and energy of the electron beam. The main emission recorded occurred several 100 nsec after the focus was over, which implies that the electric fields driving the beam existed for this duration. It is suggested that the fields were created by annihilation of magnetic flux for a time much longer than the focus duration.

Harries, W. L.↗

Measurements of electron temperature in high-energy-density plasmas using gated x-ray pinhole imaging

We present measurements of spatially and temporally resolved electron temperature in high-energy-density plasmas using gated x-ray pinhole imagers. A 2D image of bremsstrahlung x-ray self-emission from laser-driven plasma plumes is detected at the same time through two pinholes covered with different filter materials. By comparing the attenuated signal through each filter, a spatially resolved electron temperature as low as 0.1 keV can be estimated. Measurements of the plasma plume taken from different directions indicate that imaging through extended plasmas has a negligible effect on the temperature estimates. Methods for estimating the expected signal, selecting filters, and incorporating the response of the detector are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Understanding reliability and some limitations of the images and spectra reconstructed from a multi-monochromatic x-ray imager

Temperature and density asymmetry diagnosis is critical to advance inertial confinement fusion (ICF) science. A multi-monochromatic x-ray imager (MMI) is an attractive diagnostic for this purpose. The MMI records the spectral signature from an ICF implosion core with time resolution, 2-D space resolution, and spectral resolution. While narrow-band images and 2-D space-resolved spectra from the MMI data constrain temperature and density spatial structure of the core, the accuracy of the images and spectra depends not only on the quality of the MMI data but also on the reliability of the post-processing tools. In this paper, we synthetically quantify the accuracy of images and spectra reconstructed from MMI data. Errors in the reconstructed images are less than a few percent when the space-resolution effect is applied to the modeled images. The errors in the reconstructed 2-D space-resolved spectra are also less than a few percent except those for the peripheral regions. Spectra reconstructed for the peripheral regions have slightly but systematically lower intensities by ~6% due to the instrumental spatial-resolution effects. However, this does not alter the relative line ratios and widths and thus does not affect the temperature and density diagnostics. We also investigate the impact of the pinhole size variation on the extracted images and spectra. A 10% pinhole size variation could introduce spatial bias to the images and spectra of ~10%. A correction algorithm is developed, and it successfully reduces the errors to a few percent. Finally, it is desirable to perform similar synthetic investigations to fully understand the reliability and limitations of each MMI application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray phase contrast and absorption imaging for the quantification of transient cavitation in high-speed nozzle flows

In this work, high-flux synchrotron radiation has been employed in a time-resolved manner to characterise the distinct topology features and dynamics of different cavitation regimes arising in a throttle orifice with an abrupt flow-entry contraction. Radiographs obtained though both X-ray phase- contrast and absorption imaging have been captured at 67,890 frames per second. The flow lied in the turbulent regime (Re=35,500), while moderate (CN=2.0) to well-established (CN=6.0) cavitation conditions were examined encompassing the cloud and vortical cavitation regimes with pertinent transient features, such as cloud-cavity shedding. X-ray Phase-Contrast Imaging (XPCI), exploiting the shift in the X-ray wave phase during interactions with matter, offers sharp-refractive index gradients in the interface region. Hence, it is suitable for capturing fine morphological fluctuations of transient cavitation structures. Nevertheless, the technique cannot provide information on the quantity of vapour within the orifice. Such data have been obtained utilising absorption imaging, where beam attenuation is not associated with scattering and refraction events, and hence can be explicitly correlated with the projected vapour thickness in line-of-sight measurements. A combination of the two methods is proposed, as it has been found is capable of quantifying the vapour content arising in the complex nozzle flow, while also faithfully illustrating the dynamics of the highly-transient cavitation features.

42 ENGINEERING↗

Plasma-Bubble Imaging and Spectroscopy (Final Report)

The aim of this research was to capture time- and space-resolved behavior of breakdown initiation and development in water with gas bubbles injected between the electrodes when excited with microsecond voltage pulses. The results were directly compared to our previous results from a PCRF collaboration on the development of an electrical discharge in a gas bubble immersed in liquids with different conductivities when excited by nanosecond voltage pulses. For nanosecond regimes, cavitation seems to play a major role in plasma breakdown for low conductivities and discharge initiates at an electrode. On microsecond timescales, where cavitation does not play a role, it has been hypothesized that breakdown in water occurs first in bubbles on or near the electrodes, pre-existing or formed thermally.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-harmonic spin-shearing interferometry for spatially resolved EUV magneto-optical spectroscopy

We present a method for achieving hyperspectral magnetic imaging in the extreme ultraviolet (EUV) region based on high-harmonic generation (HHG). By interfering two mutually coherent orthogonally-polarized and laterally-sheared HHG sources, we create an EUV illumination beam with spatially-dependent ellipticity. By placing a magnetic sample in the beamline and sweeping the relative time delay between the two sources, we record a spatially resolved interferogram that is sensitive to the EUV magnetic circular dichroism of the sample. This image contains the spatially-resolved magneto-optical response of the sample at each harmonic order, and can be used to measure the magnetic properties of spatially inhomogeneous magnetic samples.

Optics↗