Search NASA⌕ Search

SEARCH · Search NASA

Results for “Windows”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

TH-E-BRE-05: Analysis of Dosimetric Characteristics in Two Leaf Motion Calculator Algorithms for Sliding Window IMRT

Purpose: The Smart leaf motion calculator (SLMC) in Eclipse treatment planning system is an advanced fluence delivery modeling algorithm as it takes into account fine MLC features including inter-leaf leakage, rounded leaf tips, non-uniform leaf thickness, and the spindle cavity etc. In this study, SLMC and traditional Varian LMC (VLMC) algorithms were investigated, for the first time, in dosimetric characteristics and delivery accuracy of sliding window (SW) IMRT. Methods: The SW IMRT plans of 51 cancer cases were included to evaluate dosimetric characteristics and dose delivery accuracy from leaf motion calculated by SLMC and VLMC, respectively. All plans were delivered using a Varian TrueBeam Linac. The DVH and MUs of the plans were analyzed. Three patient specific QA tools - independent dose calculation software IMSure, Delta4 phantom, and EPID portal dosimetry were also used to measure the delivered dose distribution. Results: Significant differences in the MUs were observed between the two LMCs (p≤0.001).Gamma analysis shows an excellent agreement between the planned dose distribution calculated by both LMC algorithms and delivered dose distribution measured by three QA tools in all plans at 3%/3 mm, leading to a mean pass rate exceeding 97%. The mean fraction of pixels with gamma < 1 of SLMC is slightly lower than that of VLMC in the IMSure and Delta4 results, but higher in portal dosimetry (the highest spatial resolution), especially in complex cases such as nasopharynx. Conclusion: The study suggests that the two LMCs generates the similar target coverage and sparing patterns of critical structures. However, SLMC is modestly more accurate than VLMC in modeling advanced MLC features, which may lead to a more accurate dose delivery in SW IMRT. Current clinical QA tools might not be specific enough to differentiate the dosimetric discrepancies at the millimeter level calculated by these two LMC algorithms. NIH/NIGMS grant U54 GM104944, Lincy Endowed Assistant Professorship.

60 APPLIED LIFE SCIENCES↗

SU-E-T-200: Comparison Between HybridARC and Sliding Windows IMRT for Spine SBRT Tumors

Purpose: Spine SBRT treatments require high dose to PTV, located close to OAR. Treatment time should be short due to patient condition. The objective of this work is to compare HybridARC (HA) with sliding windows IMRT treatment modality Methods: A 6MV photon beam with 1000MU/min (SRS beam) produced by a NovalisTX (Varian/BrainLAB) equipped with HDMLC was used. The TPS was iPlan v4.5.3 (BrainLAB). Treatment plans comparison was done for 5 patients. Dose prescription was 27Gy in 3 fractions. HA used 1 arc plus 3 (HA), 5 (HA5) and 8 (HA8) IMRT fields. HA plans used OAR high. Between 60–40% of the prescribed dose was given by the arc. IMRT plans used 15 beams. Treatment times, MU, CI, V50% and V20% was used for plans comparisons. Results: Assuming IMRT plan as reference, the treatment time was reduced by −14.6% with HA8, −8.6% with HA5 and −23% with HA3. Increasing arc dose proportion in HA (arc MU > 2000) requires 2 or more arcs which increments treatment time. HA3 and HA5 exhibits beam hold off for fixed IMRT fields which in some cases need to be split in 2 segments. MU varied +4% with HA8, +3.7% with HA5 and −5% with HA3. CI increased +5% with HA8, +23% with HA5 and +37% with H3. V50% increased +5% with HA8, +43% with HA5 and +62% with HA3. V20% increased +13.2% with HA8, +7.6% with HA5 and +1% with HA3. OARs doses were keep within tolerances in all plans. Conclusion: HybridARC for spine SBRT with 8 fix IMRT gantry angle shows a treatment time reduction, comparable MU and similar dose conformation to dMLC IMRT. HybridARC with 5 or 3 fix IMRT fields produce undesirable beam hold off, worse dose conformation and increments the total volume with 50% of the prescribed dose.

60 APPLIED LIFE SCIENCES↗

SU-F-T-273: Using a Diode Array to Explore the Weakness of TPS DoseCalculation Algorithm for VMAT and Sliding Window Techniques

Purpose: To identify the weakness of dose calculation algorithm in a treatment planning system for volumetric modulated arc therapy (VMAT) and sliding window (SW) techniques using a two-dimensional diode array. Methods: The VMAT quality assurance(QA) was implemented with a diode array using multiple partial arcs that divided from a VMAT plan; each partial arc has the same segments and the original monitor units. Arc angles were less than ± 30°. Multiple arcs delivered through consecutive and repetitive gantry operating clockwise and counterclockwise. The source-toaxis distance setup with the effective depths of 10 and 20 cm were used for a diode array. To figure out dose errors caused in delivery of VMAT fields, the numerous fields having the same segments with the VMAT field irradiated using different delivery techniques of static and step-and-shoot. The dose distributions of the SW technique were evaluated by creating split fields having fine moving steps of multi-leaf collimator leaves. Calculated doses using the adaptive convolution algorithm were analyzed with measured ones with distance-to-agreement and dose difference of 3 mm and 3%.. Results: While the beam delivery through static and step-and-shoot techniques showed the passing rate of 97 ± 2%, partial arc delivery of the VMAT fields brought out passing rate of 85%. However, when leaf motion was restricted less than 4.6 mm/°, passing rate was improved up to 95 ± 2%. Similar passing rate were obtained for both 10 and 20 cm effective depth setup. The calculated doses using the SW technique showed the dose difference over 7% at the final arrival point of moving leaves. Conclusion: Error components in dynamic delivery of modulated beams were distinguished by using the suggested QA method. This partial arc method can be used for routine VMAT QA. Improved SW calculation algorithm is required to provide accurate estimated doses.

60 APPLIED LIFE SCIENCES↗

SU-F-T-373: Monte Carlo Versus Pencil Beam Dose Calculation for Spine SBRT Treatments Using HybridARC and Sliding Windows IMRT

Purpose: The purpose of this work was to quantify the dosimetric impact of Monte Carlo (MC) dose calculation algorithm compared to Pencil Beam (PB) on Spine SBRT with HybridARC (HA) and sliding windows IMRT (dMLC) treatment modality. Methods: A 6MV beam (1000MU/min) produced by a Novalis TX (BrainLAB-Varian) equipped with HDMLC was used. HA uses 1 arc plus 8 IMRT beams (arc weight between 60–40%) and dIMRT 15 beams. Plans were calculated using iPlan v.4.5.3 (BrainLAB) and the treatment dose prescription was 27Gy in 3 fractions. Dose calculation was done by PB (4mm spatial resolution) with heterogeneity correction and MC dose to water (4mm spatial resolution and 4% mean variance). PTV and spinal cord dose comparison were done. Study was done on 12 patients. IROC Spine Phantom was used to validate HA and quantify dose variation using PB and MC algorithm. Results: The difference between PB and MC for PTV D98%, D95%, Dmean, D2% were 2.6% [−5.1, 6.8], 0.1% [−4.2, 5.4], 0.9% [−1.5, 3.8] and 2.4% [−0.5, 8.3]. The difference between PB and MC for spinal cord Dmax, D1.2cc and D0.35cc were 5.3% [−6.4, 18.4], 9% [−7.0, 17.0] and 7.6% [−0.6, 14.8] respectively. IROC spine phantom shows PTV TLD dose variation of 0.98% for PB and 1.01% for MC. Axial and sagittal film plane gamma index (5%-3mm) was 95% and 97% for PB and 95% and 99% for MC. Conclusion: PB slightly underestimates the dose for the PTV. For the spinal cord PB underestimates the dose and dose differences could be as high as 18% which could have unexpected clinical impact. CI shows no variation between PB and MC for both treatment modalities Treatment modalities have no impact with the dose calculation algorithms used. Following the IROC pass-fail criteria, treatment acceptance requirement was fulfilled for PB and MC.

60 APPLIED LIFE SCIENCES↗

Hydrologic windows into the crystalline basement and their controls on groundwater flow patterns across the Paradox Basin, western USA

Conceptual models of sedimentary basin groundwater flow systems typically assume that the crystalline basement acts as an impermeable boundary and can be neglected. In this study, we use hydrologic models constrained by isotopic and geochemical datasets to argue that the La Sal Mountains, Utah, USA, act as a hydrologic window into the Paradox Basin’s lower aquifer system and underlying crystalline basement. We conducted a sensitivity study in which we varied crystalline basement/laccolith permeability as well as fault zone connectivity along a cross-sectional transect from the La Sal Mountains to Lisbon Valley. When the crystalline basement/laccolith units are set at relatively permeable levels (10–14 m 2 ), simulated tracers that include total dissolved solids, oxygen isotopic composition of pore fluids (δ 18 O), and groundwater residence times are in closest agreement with field measurements. Model results indicate that pore fluids in the basal aquifer system underlying the Paradox Formation confining unit are a mixture of relatively young meteoric fluids and older Paradox Formation brines. The presence of faults did not significantly modify fluid exchange between the upper and lower aquifer systems. This was due, in part, to underpressuring within the Paradox Formation. Our study concludes that the Paradox Basin represents a regional recharge area for the Colorado Plateau, with groundwater discharge occurring along the Colorado River within the Grand Canyon some 375 km away to the southwest. This is only possible with a permeable crystalline basement. Our findings help explain the genesis of Mississippi Valley-type ore deposits of the US Midcontinent, where the presence of a permeable basement may be useful in addressing issues related to solute mass and energy balance.

54 ENVIRONMENTAL SCIENCES↗

Window Glasses: State and Prospects

Analysis and generalization of the results of investigations devoted to the improvement of optical properties have been carried out, and descriptions of a structure and a reaction mechanism of available and promising window glasses with solar radiation are presented. All devices are divided into groups with static constant and dynamic regulated spectral characteristics. The group of static glasses includes heat-protective and spectrally selective glasses with low-emissivity coatings and infrared filters with dispersed plasmonic nanoparticles. Electrochromic glasses, nanostructured dynamic infrared filters, and glasses with separated regulation of the transmission of visible-light and near-infrared radiation are dynamic devices. It is noted that the use of mesoporous films made of plasmonic nanoparticles open up especially wide possibilities. Their application allows one to realize a dynamic separated regulation of the transmission of visible light and nearinfrared radiation in which, under the gradual increase in the electric potential on the glass, mechanisms of plasmon and polaron reduction of solar radiation gradually change the glass’ condition from light warm to light cold and then to dark cold consecutively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multilayer X-ray mirrors for the (4.4-5)-nm carbon-window spectral region

Cr/C-based multilayer X-ray mirrors intended for the reflection of X-ray radiation in the 'carbon-window' spectral region ({lambda} = 4.4-5 nm) are fabricated and studied. The structures are formed by magnetron sputtering at different deposition parameters. Under normal incidence, record reflection coefficients up to 15% are reached. The structural parameters of the mirrors are investigated by reflectometry at wavelengths of 0.154 and 4.47 nm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Soft X-ray microscopy in the spectral region of 'carbon window' with the use of multilayer optics and a laser-plasma source

This paper reports on the fabrication and testing of multilayer mirrors for X-ray optical systems operating in the 'carbon window' region (at wavelengths from 4.5 to 5.0 nm) and the results of their application in soft X-ray imaging of the internal structure of organic objects. The developed approaches to the fabrication and control of graded Co/C multilayer coatings have made it possible to create an X-ray multimirror system with a maximum known entrance aperture and throughput. The use of the developed high-spatial-resolution X-ray optics can significantly extend the field of practical application of soft X-ray absorption microscopy based on compact laser-plasma sources.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Light-heavy-ion collisions: a window into pre-equilibrium QCD dynamics?

Relativistic collisions of light on heavy ions (p + Au at $\sqrt{s}$ = 7.7 GeV, p + Au, d + Au, 3 He + Au at $\sqrt{s}$ = 62.4 GeV and 200 GeV and p + Pb, 3 He + Pb at $\sqrt{s}$ = 5.02 TeV) are simulated using “superSONIC”, a model that includes pre-equilibrium flow, viscous hydrodynamics and a hadronic cascade afterburner. Even though these systems have strong gradients and only consist of at most a few tens of charged particles per unit rapidity, one finds evidence that a hydrodynamic description applies to these systems. Based on these simulations, the presence of a triangular flow component in d + Au collisions at $\sqrt{s}$ = 200 GeV is predicted to be similar in magnitude to that found in 3 He + Au collisions. Moreover, the v 3 (p T ) ratio of 3 He + Au to d + Au is found to be sensitive to the presence of pre-equilibrium flow. This would imply an experimentally accessible window into pre-equilibrium QCD dynamics using light-heavy-ion collisions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Open Host Network Packet Process Correlator for Windows

The Hone sensors are packet-process correlation engines that log the relationships between applications and the communications they are responsible for. Hone sensors are available for a variety of platforms including Linux, Windows, and MacOSX. Hone sensors are designed to help analysts understand the meaning of communications on a deeper level by associating the origin or destination process to the communication. They do this by tracing communications on a per-packet basis, through the kernel of the operating system to determine their ultimate source/destination on the monitored machine.

Source record↗

Berkeley Lab WINDOW Calc Engine (CalcEngine) v2

Calculation of thermal and optical properties of glass, windows, and shades. Calculational code only, no GUI. The software hosted at this repository is one out of five repositories that make up this entire project. The others can be found at the following DOIs: 10.11578/dc.20190522.2, 10.11578/dc.20190522.4, 10.11578/dc.20190522.5, and 10.11578/dc.20190524.1.

Kohler, Christian↗

Berkeley Lab WINDOW Calc Engine (CalcEngine) v2

Calculation of thermal and optical properties of glass, windows, and shades. Calculational code only, no GUI. The software hosted at this repository is one out of five repositories that make up this entire project. The others can be found at the following DOIs: 10.11578/dc.20190522.1, 10.11578/dc.20190522.4, 10.11578/dc.20190522.5, and 10.11578/dc.20190524.1.

Kohler, Christian↗

Berkeley Lab WINDOW Calc Engine (CalcEngine) v2

Calculation of thermal and optical properties of glass, windows, and shades. Calculational code only, no GUI. The software hosted at this repository is one out of five repositories that make up this entire project. The others can be found at the following DOIs: 10.11578/dc.20190522.1, 10.11578/dc.20190522.2, 10.11578/dc.20190522.5, and 10.11578/dc.20190524.1.

Kohler, Christian↗

Berkeley Lab WINDOW Calc Engine (CalcEngine) v2

Calculation of thermal and optical properties of glass, windows, and shades. Calculational code only, no GUI. The software hosted at this repository is one out of five repositories that make up this entire project. The others can be found at the following DOIs: 10.11578/dc.20190522.1, 10.11578/dc.20190522.2, 10.11578/dc.20190522.4, and 10.11578/dc.20190524.1.

Mitchell, Robin↗

Berkeley Lab WINDOW Calc Engine (CalcEngine) v2

Calculation of thermal and optical properties of glass, windows, and shades. Calculational code only, no GUI. The software hosted at this repository is one out of five repositories that make up this entire project. The others can be found at the following DOIs: 10.11578/dc.20190522.1, 10.11578/dc.20190522.2, 10.11578/dc.20190522.4 and 10.11578/dc.20190522.5.

Mitchell, Robin↗

Preoperative Pazopanib in High-Risk Soft Tissue Sarcoma: Phase II Window-of Opportunity Study of the German Interdisciplinary Sarcoma Group (NOPASS/GISG-04)

Background: Preoperative devascularization might improve local control and thus the outcome of patients with soft tissue sarcoma (STS). The multikinase inhibitor pazopanib has antiangiogenic effects and is approved for treating metastatic STS. We conducted a trial of preoperative pazopanib therapy in high-risk STS. Methods: This single-arm, phase II trial included patients with resectable, non-metastatic, treatment-naïve, high-risk STS. Patients received pazopanib 800 mg daily while waiting for surgery (21-day ‘window of opportunity’). The primary endpoint was metabolic response rate (MRR; proportion of patients with ≥ 50% reduction of mean standardized uptake value [SUV{sub mean}] in post- vs. pretreatment fluorodeoxyglucose–positron emission tomography/computed tomography [FDG-PET-CT]). Planned sample size was 35 patients (type I error, 5%; type II error, 20%). A translational substudy explored associations between response and concentration of circulating angiogenic factors. Results: Futility analysis was performed after 21 patients (11 female, mean age 67 years; liposarcoma n = 15); 17/21 patients were evaluable for the primary endpoint. The MRR was 1/17 (5.9%, 95% confidence interval < 0.01–0.29). Mean change in SUV{sub mean} of post- versus pretreatment PET was a 6% decrease (range 65% decrease to 34% increase); 7/21 (33.3%) patients had 12 grade 3/4 toxicities, and 19/21 (95.2%) patients were resected (all R0). One (4.8%) patient suffered a grade 4 postoperative complication (anastomotic leakage). Circulating endothelial progenitor cells, soluble vascular endothelial growth factor, and angiopoietin-2 concentrations showed no relevant changes during treatment. Conclusions: Although this study showed that preoperative pazopanib is not effective for unselected high-risk STS patients, relevant treatment effects were observed in a single patient. Future research needs to better define subgroups potentially benefiting from preoperative pazopanib treatment. ClinicalTrials.gov identifier: NCT01543802.

62 RADIOLOGY AND NUCLEAR MEDICINE↗