Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Emittance and Phase Space Exchange for Advanced Beam Manipulation and Diagnostics

Alternative chicane-type beam lines are proposed for exact emittance exchange between transverse phase space (x,x') and longitudinal phase space (z,{delta}), where x is the transverse position, x' is the transverse divergence, and z and {delta} are relative longitudinal position and energy deviation with respect to the reference particle. Methods to achieve exact phase space exchanges, i.e., mapping x to z, x' to {delta}, z to x, and {delta} to x', are suggested. Schemes to mitigate and completely compensate for the thick-lens effect of the transverse cavity on emittance exchange are studied. Some applications of the phase space exchange for advanced beam manipulation and diagnostics are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design improvements to the SNS ion source and diagnostics

The U.S. Spallation Neutron Source (SNS) is a state-of-the-art neutron scattering facility delivering the world's most intense pulsed-neutron beams to a wide array of instruments which are used to conduct investigations in many fields of science and engineering. The accelerator system is fed by an RF-driven, multicusp, H - ion source which nominally provides pulsed beam currents of 50-60 mA (1ms, 60Hz). This report provides a discussion of ongoing design improvements to the SNS ion source and Low Energy Beam Transport (LEBT) as well as diagnostic upgrades undertaken since the previous ICIS conference. These improvements include (i) simple mechanical modifications to the source outlet aperture which resulted in dramatically increased extracted beam current and comparable or lower emittance at similar beam currents, (ii) design improvements to the LEBT chopper target which will enable full power beam-dumping during physics studies, (iii) refinement of the SNS Allison emittance scanner that has enabled the first reliable LEBT beam measurements at full beam power (65kV, 50-100mA, 1ms, 60Hz) on the SNS ion source test stand and (iv) the implementation of a thermal imaging camera for the monitoring the LEBT electrode temperatures. (v) The design of an advanced Cs system, capable of more efficient Cs utilization with significantly lower Cs losses from the source is also presented. Mechanical details, computational simulations and experimental results are discussed within the context of these improvements.

47 OTHER INSTRUMENTATION↗

Summary of the 2014 Beam-Halo Monitoring Workshop

Understanding and controlling beam halo is important for high-intensity hadron accelerators, for high-brightness electron linacs, and for low-emittance light sources. This can only be achieved by developing suitable diagnostics. The main challenge faced by such instrumentation is the high dynamic range needed to observe the halo in the presence of an intense core. In addition, measurements must often be made non-invasively. This talk summarizes the one-day workshop on Beam-Halo Monitoring that was held at SLAC on September 19 last year, immediately following IBIC 2014 in Monterey. Workshop presentations described invasive techniques using wires, screens, or crystal collimators, and non-invasive measurements with gas or scattered electrons. Talks on optical methods showed the close links between observing halo and astronomical problems like observing the solar corona or directly observing a planet orbiting another star.

43 PARTICLE ACCELERATORS↗

Electron Cloud at Low Emittance in CesrTA

The Cornell Electron Storage Ring (CESR) has been reconfigured as a test accelerator (CesrTA) for a program of electron cloud (EC) research at ultra low emittance. The instrumentation in the ring has been upgraded with local diagnostics for measurement of cloud density and with improved beam diagnostics for the characterization of both the low emittance performance and the beam dynamics of high intensity bunch trains interacting with the cloud. A range of EC mitigation methods have been deployed and tested and their effectiveness is discussed. Measurements of the electron cloud’s effect on the beam under a range of conditions are discussed along with the simulations being used to quantitatively understand these results.

43 PARTICLE ACCELERATORS↗

Simulations and Analysis of an Infrared Prism Spectrometer for Ultra-short Bunch Length Diagnostics at the Linac Coherent Light Source

We require a means of determining the minimum achievable bunch length at the Linac Coherent Light Source (LCLS) at SLAC National Accelerator Laboratory. Current methods of measurement in the time domain do not have the resolution to measure ultra-short bunch lengths below 10 fs. An alternative method has been designed, using a single-shot near- to mid-infrared prism spectrometer for bunch length diagnosis in the frequency domain. This design requires the precision alignment of sensitive optical equipment and complete understanding of the spectrum reaching the spectrometer's detector surface. This paper provides information on preliminary simulations designed to model beam behavior in the optical set-up and at the detector surface for comparison to measured values as an indication of the current achievable optical alignment and the study of optimal detector orientation. The results of these simulations indicate the necessity for a method of greater precision in optical alignment and further study of achievable spectrometer range!

OTHER↗

Erosion rate diagnostics in ion thrusters using laser-induced fluorescence

We have used laser-induced fluorescence (LIF) to monitor the charge-exchange ion erosion of the molybdenum accelerator electrode in ion thrusters. This real-time, nonintrusive method was implemented by operating a 30cm-diam ring-cusp thruster using xenon propellant. With the thruster operating at a total power of 5 kW, laser radiation at a wavelength of 390 nm (corresponding to a ground state atomic transition of molybdenum) was directed through the extracted ion beam adjacent to the downstream surface of the molybdenum accelerator electrode. Molybdenum atoms, sputtered from this surface as a result of charge-exchange ion erosion, were excited by the laser radiation. The intensity of the laser-induced fluorescence radiation, which is proportional to the sputter rate of the molybdenum atoms, was measured and correlated with variations in thruster operating conditions such as accelerator electrode voltage, accelerator electrode current, and test facility background pressure. We also demonstrated that the LIF technique has sufficient sensitivity and spatial resolution to evaluate accelerator electrode lifetime in ground-based test facilities.

Gaeta, C. J.↗

Perspectives on Machine Learning-assisted Plasma Medicine: Towards Automated Plasma Treatment

Cold atmospheric plasmas (CAPs) have shown great promise for medical applications through their synergistic chemical, electrical, and thermal effects, which can induce therapeutic outcomes. However, safe and reproducible plasma treatment of complex biological surfaces poses a major hurdle to the widespread adoption of CAPs for medical applications. Predictive modeling of the mutual interactions between the plasma and biological surfaces and, thus, systematic approaches to quantify and predict plasma treatment outcomes remain largely elusive due to the lack of mechanistic understanding of plasma-surface interactions that can span across vastly different length-and time-scales. In addition, real-time sensing capabilities in biomedical CAP devices are often limited, which can be detrimental to plasma treatment due to the intrinsic plasma and surface variability during the treatment, as well as sensitivity to external perturbations. All of these challenges can make reproducible and effective plasma treatment of biological surfaces difficult to realize, which is further compounded by errors due to human operation of hand-held CAP devices. Machine learning and data-driven approaches can be particularly useful in addressing these challenges in three major ways: (i) data-driven modeling of hard-to-model plasma-surface interactions and plasma treatment outcomes; (ii) learning data analytics for plasma and surface diagnostics in real-time; and (iii) developing predictive controllers that enable reliable and effective CAP treatments. Furthermore, this paper discusses the promise of machine learning to accelerate plasma medicine research in these areas, toward machine learning-assisted and automated CAP treatment of complex biological surfaces.

60 APPLIED LIFE SCIENCES↗

Development of a Simple and Rapid Diagnostic Method for Polymer-Electrolyte Fuel Cells

A simple and fast diagnostic tool has been developed for analyzing polymer-electrolyte fuel-cell degradation. The tool is based on analyzing changes in polarization curves of a cell over its lifetime. The shape of the polarization-change curve and its sensitivity to oxygen concentration are found to be unique for each degradation pathway based on analysis from a detailed 2-D numerical model of the cell. Using the polarization-change curve methodology, the primary mechanism for degradation (kinetic, ohmic, and/or transport related) can be identified. Here, the technique is applied to two sets of data to explain performance changes after two different cells undergo voltage-cycling accelerated stress test, where it is found that changes are kinetic and then ohmic or transport in nature depending on the cell type. The diagnostic tool provides a simple method for rapid determination of primary degradation mechanisms. Finally, areas for more detailed future investigations are also summarized.

08 HYDROGEN↗

Preparations for a high gradient inverse free electron laser experiment at Brookhaven national laboratory

Preparations for an inverse free electron laser experiment at Brookhaven National Laboratory's Accelerator Test Facilty are presented. Details of the experimental setup including beam and laser transport optics are first discussed. Next, the driving laser pulse structure is investigated and initial diagnostics are explored and compared to simulations. Finally, planned improvements to the experimental setup are discussed.

43 PARTICLE ACCELERATORS↗

AI-Ready Control System for the Fermilab Accelerator Complex

Reliable, high-intensity operation of the Fermilab Accelerator Complex is critical to the success of the Long-Baseline Neutrino Facility and Deep Underground Neutrino Experiment. We describe the requirements and infrastructure necessary to support routine use of artificial intelligence and machine learning (AI/ML) in the accelerator control system. Three capabilities are identified: a machine learning operations (MLOps) framework standardizing the lifecycle of AI/ML automation from data management through deployment and monitoring; a data quality framework defining and enforcing standards required to build trustworthy AI/ML applications; and workflow integration with large language models to assist physicists, engineers, and operators with information retrieval, code development, and routine analysis. Use cases spanning beam diagnostics, beam control, and support system automation illustrate the technical requirements across the complex.

43 PARTICLE ACCELERATORS↗

A plasma deflagration accelerator as a platform for laboratory astrophysics

The replication of astrophysical flows in the laboratory is critical for isolating particular phenomena and dynamics that appear in complex, highly-coupled natural systems. Particularly, plasma jets are observed in astrophysical contexts at a variety of scales, typically at high magnetic Reynolds number and driven by internal currents. In this paper, we present detailed measurements of the plasma parameters within deflagration-produced plasma jets, the scaling of these parameters against both machine operating conditions and the corresponding astrophysical phenomena. Using optical and spectroscopic diagnostics, including Schlieren cinematography, we demonstrate the production of current-driven plasma jets of »100 km/s and magnetic Reynolds numbers of »100, and discuss the dynamics of their acceleration into vacuum. Finally, the results of this study will contribute to the reproduction of various types of astrophysical jets in the laboratory and indicate the ability to further probe active research areas such as jet collimation, stability, and interaction.

79 ASTRONOMY AND ASTROPHYSICS↗

Dynamic Characterization of Mock Explosive Material Using Reverse Taylor Impact Experiments

The motivation for the current study is to evaluate the dynamic loading response of an inert mock explosive material used to replicate the physical and mechanical properties of LX-17-1 and PBX 9502 insensitive high explosives. The evaluation of dynamic material parameters is needed for predicting the deformation behavior including the onset of failure and intensity of fragmentation resulting from high velocity impact events. These parameters are necessary for developing and validating physically based material constitutive models that will characterize the safety and performance of energetic materials. The preliminary study uses a reverse Taylor impact configuration that was designed to measure the dynamic behavior of the explosive mock up to and including associated fragmentation. A stationary rod-shaped specimen was impacted using a compressed-gas gun by accelerating a rigid steel anvil attached to a sabot. The impact test employed high-speed imaging and velocity interferometry diagnostics for capturing the transient deformation of the sample at discrete times. Once established as a viable experimental technique with mock explosives, future studies will examine the dynamic response of insensitive high explosives and propellants.

36 MATERIALS SCIENCE↗

Guidelines for investigating causality of sequence variants in human disease

The discovery of rare genetic variants is accelerating, and clear guidelines for distinguishing disease-causing sequence variants from the many potentially functional variants present in any human genome are urgently needed. Without rigorous standards we risk an acceleration of false-positive reports of causality, which would impede the translation of genomic research findings into the clinical diagnostic setting and hinder biological understanding of disease. Here we discuss the key challenges of assessing sequence variants in human disease, integrating both gene-level and variant-level support for causality. We propose guidelines for summarizing confidence in variant pathogenicity and highlight several areas that require further resource development.

59 BASIC BIOLOGICAL SCIENCES↗

Radiation Hydrodynamics of Stainless Steel Wire Arrays on the Z Accelerator

Experiments on the Z accelerator with nested stainless steel wire arrays produced K-shell x-ray yields exceeding 50 kJ in the energy range 5.5 to 8 keV. Stainless steel (Z = 24-28) can barely be ionized to the K-shell on Z, and the spectra are therefore sensitive to the details of the implosion. We have simulated the implosion dynamics of stainless steel wire arrays with diameters ranging from 4.5 to 8.0 centimeters using a detailed configuration non-LTE radiation hydrodynamics model. Reasonable agreement with total and K-shell experimental yields was obtained for the various array configurations. A comparison is made between the 1-D and 2-D simulations for shot Z-578.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Design of Superconducting Wiggler Beamline BL7 at SAGA-LS

A new hard X-ray beamline has been designed at Saga Light Source. The beamline, named BL7, uses a newly developed 4-Tesla superconducting wiggler as a light source in order to cover a wide energy range to 30 keV. This beamline has a simple optics: a double-crystal monochromator and a Rh-coated bent-cylindrical mirror and can supply a focused beam with a photon flux about 1x10{sup 10} photons/s and a sub-millimeter size. Several experiments will be performed in the experimental station: e.g. protein crystallography; X-ray micro computed tomography; X-ray absorption fine structure measurement.

43 PARTICLE ACCELERATORS↗

Study of x-ray radiant characteristics and thermal radiation redistribution in CH foam filling cylindrical cavities

Experiments are presented, which demonstrate the properties of x-ray radiation and redistribution of radiant thermal energy in high Z cylindrical cavities filled with low Z CH foam. Time integrated spectra records were obtained by a calibrated space-resolved transmission grating spectrometer. The x-ray radiation became weaker in intensity and was changed to a softer near-Planckian radiation light after a 1500 {mu}m long transport in the foam filling cavity. The experimental redistribution of the radiant thermal energy was plotted and compared to the numerical results of a simplified model. Good agreements have been achieved.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Imaging and Coherence Beamline I13 at Diamond

The coherence and imaging beamline I13 is dedicated to hard x-ray imaging on the micro- and nano-lengthscale, performing microscopy either in direct or reciprocal space. For both, lens-based and lensless imaging, two independent stations will be operated in a separate building at a distance of 250 m from the source. The imaging branch will perform in-line phase contrast imaging and tomography over a large field of view in the 6- to 35-keV energy range. In addition, it will be possible to switch to full-field microscopy with 50-nm spatial resolution. Other microscopies will be developed according to the scientific needs. Resolution beyond the limitations given by the detector and x-ray optics will be achieved with techniques working in the far field. Coherent x-ray diffraction (CXRD) and other coherent diffraction imaging techniques such as ptychography will also be implemented on the same 'coherence' branch. The beamline hosts a number of innovative features such as the so-called 'mini-beta' layout for electron optics in the storage ring or new concepts for beamline instrumentation. The stations will be operational in 2011.

43 PARTICLE ACCELERATORS↗

Improved Scanning Geometry to Collect 3D-Geometry Data in Flat Samples

3D integration through silicon technology of integrated circuits challenges non-destructive testing methods. 3D x-ray methods are the techniques of choice to localize defects in interconnects. The development of high-power x-ray sources enabled the use of x-ray microscopy in laboratory tools. Those devices are able to resolve features down to 40 nm in an acceptable measurement time. However, the field of view is very limited to 16 {mu}m in high-resolution mode and to 65 {mu}m in large-field-of-view mode. To record tomography data, the size of the samples must not exceed the field of view to circumvent specific artifacts. Semiconductor samples usually do not fulfill the condition mentioned above since they have the shape of flat sheets. Therefore limited-angle tomography is typically used. The missing angles cause typical capping artifacts and poor signal-to-noise ratio. We present a modified scanning geometry that overcomes some of the artifacts and yields a better image quality. The geometry and potential applications are presented in comparison to the traditional limited-angle tomography.

07 ISOTOPE AND RADIATION SOURCES↗