Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Analysis of TATB by HPLC-DAD (V.1.4)

The following procedure describes the method for determining the purity of 1,3,5-triamino 2,4,6-trinitrobenzene (TATB) samples using a High-Performance Liquid Chromatography (HPLC) system fitted with a Diode Array Detector (DAD). This procedure is also applicable for the detection of some impurities present in TATB.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Identification and Quantification of Photosynthetic Pigments in Algae (Laboratory Analytical Procedure (LAP))

The Laboratory Analytical Procedure (LAP) outlined here describes a method to quantitatively extract phytopigments from microalgae biomass, as well as to identify and quantify individual pigments based on separation and detection with a High-Performance Liquid Chromatography (HPLC) system coupled to a Diode Array Detector (DAD). Pigments were extracted with greater than 95 % extraction efficiency. Chromatographic conditions allowed for isomeric resolution between pigments and identification based on UV/Vis spectra and comparison to analytical standards.

09 BIOMASS FUELS↗

Diagnostics for PSR Upgrade

This report discusses the diagnostics upgrade plan for the PSR. The PSR diagnostics under discussion include beam position and phase monitor (BPPM), wirescanners, wall current monitors, bunch shape monitors, laser notchers, and diamond array detectors. Existing diagnostics at the PSR include beam position monitors (BPM), a wirescanner, and a wall current monitor. All existing diagnostics need modernization, as part of the PSR upgrade plan. Meanwhile, we will introduce minor changes to improve the existing setups, which will enhance the performance and the longevity of the diagnostics equipment and components in the upgraded PSR operation. On the other hand, new, advanced, and available diagnostic technologies at a high technology readiness level (TRL) can also be considered for implementation for the PSR upgrade. In this note, we go through all types of diagnostics, introducing their basic principle, operating status, and plans for the PSR upgrade.

43 PARTICLE ACCELERATORS↗

Constraining Neutron Star Structure with Indirect Nuclear Reaction Studies

There were zero expenditures charged against the DE-SC0019042 account after 31 August 2022, i.e., there were no charges during the reporting period. The remaining graduate student that was supported by DE-SC0019042, Nisha Singh, has been supported by another grant, DE-FG02-88ER40387 (PI: Carl R. Brune), since 1 September 2022. She has continued with the same projects that were supported by DE-SC0019042, the determination of the level density in 28 Si via the 27Al(d; n) 28 Si reaction and development of an Si detector array for measuring charged-particle coincidences with neutrons. She continues to make good progress towards her Ph.D.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Using DAPPER to extract the photon strength function of 58Fe using the inverse Oslo and shape methods

The photon strength function of 58 Fe has been extracted using both the Oslo and Shape methods from particle-γ coincidence data measured using the Detector Array for Photons, Protons, and Exotic Residues, which probes nuclei utilizing (d,p) reactions in inverse kinematics. Four particle-γ coincidence matrices, each constructed with different treatments of the γ-ray energies, are explored in order to observe the impact on the resulting nuclear level density and photon strength. The final photon strength function reported is found to agree well with previous Oslo measurements of other iron isotopes. Systematic uncertainties are included, using different model parameters and their reported errors to perform the Oslo method normalization. The model-independent Shape method is explored and the functional form of the photon strength function obtained is in agreement with the Oslo method results. A low-energy enhancement is not reported for 58 Fe in this work given possible subtraction issues originating from strongly populated states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First Experimental Test of the Ratio Method

The ratio is a new reaction observable suggested to extract accurately structure information on halo nuclei. It corresponds to the ratio of differential cross sections for scattering and breakup, which is predicted to remove the uncertainty related to the reaction dynamics. We present here the first experimental test of the method for the 11 Be + 12 C collision at E Lab = 20A MeV performed at Texas A&M University. Differential cross sections for scattering and inclusive one-neutron breakup have been measured with the new detector array BlueSTEAl. The ratio of cross sections is very smooth and independent of the projectile-target interaction, which demonstrates the validity of the ratio method. We extend our analysis to existing 11 Be + 208 Pb data, confirming that the method works well on any target.

11Be↗

A Novel Dew Point Meter: Application to the Measurement of the Sulfuric Acid Dew Point for Combustion Flue Gas

Accurate knowledge of acid dew point is essential for industrial and applied combustion applications. Sulfur in the fuel or raw materials is converted to sulfur dioxide (SO2) during combustion, and a portion of the SO2 is oxidized to sulfur trioxide (SO3). The SO3 will react to form H2SO4 vapor when in the presence of water vapor. Even with just trace levels of H2SO4 vapor in the gas phase (1-10 ppm), the dew point can reach 100°C and higher. To avoid acid condensation and the resulting corrosion on heat recovery equipment, plant engineers must ensure that surface temperatures are above the acid dew point, but this decreases the efficiency of thermal energy recovery. Thus, there is a trade-off between minimizing equipment corrosion and maximizing thermal energy recovery, and the acid dew point is a key parameter for this optimization. Commercially available acid dew point meters use electric conductivity sensors. These sensors are known to greatly underestimate the dew point due to their low sensitivity. In addition, no validation testing has been reported for these units and they are often expensive. In this work, we analyze the theory of the sulfuric acid condensation and develop a novel dew point meter based on this analysis. The meter consists of a novel optical instrument that is designed to monitor the slightest appearance of condensation on a hydrophobic window surface as the surface temperature of the window is slowly decreased. In this way, an accurate measurement of the dew point is obtained under a wide range of concentrations. The basis of the instrument is that a collimated beam from a diode laser will generate forward scattered light when the beam encounters surface condensate, and a sophisticated array detector is used to sensitively monitor the onset of light scattering. The measurement procedures are established to rapidly find the acid dew point, while minimizing error. Further, to calibrate the dew point meter we developed a calibration system based on a liquid bubbler that can generate a stable gas flow with a known sulfuric acid dew point. Test results show that the dew point meter can accurately measure acid dew point over a wide range. For H2SO4 vapor concentrations as low as 6 ppm the acid dew point is measured with an error of only ~1°C. To demonstrate the versatility of this instrument, the dew point meter was adapted for use with a high-pressure flow cell to allow for measurements of the dew point of flue gas from pressurized oxy-fuel combustion in a 100 kWth pressurized reactor.

Cheng, Mao↗

A Novel Dew Point Meter: Application to the Measurement of the Sulfuric Acid Dew Point for Combustion Flue Gas

Accurate knowledge of acid dew point is essential for industrial and applied combustion. Sulfur in the fuel or raw materials is converted to sulfur dioxide (SO2) during combustion, and a portion of the SO2 is oxidized to sulfur trioxide (SO3). The SO3 will react to form H2SO4 vapor when in the presence of water vapor. Even with just trace levels of H2SO4 vapor in the gas phase (1-10 ppm), the dew point can reach 100°C and higher. To avoid acid condensation and the resulting corrosion on heat recovery equipment, plant engineers must ensure that surface temperatures are above the acid dew point, but this decreases the efficiency of the thermal energy recovery. Thus, there is a trade-off between minimizing equipment corrosion and maximizing thermal energy recovery efficiency, and the acid dew point is a key parameter for this optimization. In this work, we analyze and discuss the theory of the sulfuric acid condensation process and develop a novel dew point meter based on this analysis. The meter consists of a novel optical instrument that is designed to monitor the slightest appearance of condensation on a hydrophobic window surface, and the surface temperature of the window is slowly decreased until condensation is first observed, yielding an accurate measurement of the dew point. The basis of the instrument is that a collimated beam from a diode laser generates scattered light when encountering surface condensate, and a sophisticated array detector is used to sensitively monitor the light scattering. The measurement procedures are established to rapidly find the acid dew point, while minimizing error. Further, we propose a calibration system based on a liquid bubbler, which can generate a stable gas flow with known sulfuric acid dew point, to test the dew point meter. Test results show that the dew point meter can accurately measure the acid dew point over a wide range.

Cheng, Mao↗

Summary Statistics for Fun Dough Data Acquired at LLNL

Using x-ray computerized tomography (CT), we have characterized the x-ray linear attenuation coefficients (LAC) of a Play Dough{trademark}-like product, Fun Dough{trademark}, designated as PD. Table 1 gives the first-order statistics for each of four CT measurements, estimated with a Gaussian kernel density estimator (KDE) analysis. The mean values of the LAC range from a high of about 2100 LMHU{sub D} at 100kVp to a low of about 1100 LMHU{sub D} at 300kVp. The standard deviation of each measurement is around 1% of the mean. The entropy covers the range from 3.9 to 4.6. Ordinarily, we would model the LAC of the material and compare the modeled values to the measured values. In this case, however, we did not have the composition of the material and therefore did not model the LAC. Using a method recently proposed by Lawrence Livermore National Laboratory (LLNL), we estimate the value of the effective atomic number, Z{sub eff}, to be near 8.5. LLNL prepared about 50mL of the Fun Dough{trademark} in a polypropylene vial and firmly compressed it immediately prior to the x-ray measurements. Still, layers can plainly be seen in the reconstructed images, indicating that the bulk density of the material in the container is affected by voids and bubbles. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the data capture and image reconstruction are given in this report. Additional details may be found in the experimental SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an 80% central-core segment of volume elements ('voxels') lying completely within the specimen, away from the walls of the polypropylene vial. All of the voxels within this central core, including those comprised of voids and inclusions, are included in the statistics. We then calculated the mean value, standard deviation and entropy for (a) the four image segments and for (b) their digital gradient images. (A digital gradient image of a given image was obtained by taking the absolute value of the difference between the initial image and that same image offset by one voxel horizontally, parallel to the rows of the x-ray detector array.) The statistics of the initial image of LAC values are called 'first order statistics;' those of the gradient image, 'second order statistics.'

99 GENERAL AND MISCELLANEOUS↗

Summary Statistics for Homemade ?Play Dough? -- Data Acquired at LLNL

Using x-ray computerized tomography (CT), we have characterized the x-ray linear attenuation coefficients (LAC) of a homemade Play Dough{trademark}-like material, designated as PDA. Table 1 gives the first-order statistics for each of four CT measurements, estimated with a Gaussian kernel density estimator (KDE) analysis. The mean values of the LAC range from a high of about 2700 LMHU{sub D} 100kVp to a low of about 1200 LMHUD at 300kVp. The standard deviation of each measurement is around 10% to 15% of the mean. The entropy covers the range from 6.0 to 7.4. Ordinarily, we would model the LAC of the material and compare the modeled values to the measured values. In this case, however, we did not have the detailed chemical composition of the material and therefore did not model the LAC. Using a method recently proposed by Lawrence Livermore National Laboratory (LLNL), we estimate the value of the effective atomic number, Z{sub eff}, to be near 10. LLNL prepared about 50mL of the homemade 'Play Dough' in a polypropylene vial and firmly compressed it immediately prior to the x-ray measurements. We used the computer program IMGREC to reconstruct the CT images. The values of the key parameters used in the data capture and image reconstruction are given in this report. Additional details may be found in the experimental SOP and a separate document. To characterize the statistical distribution of LAC values in each CT image, we first isolated an 80% central-core segment of volume elements ('voxels') lying completely within the specimen, away from the walls of the polypropylene vial. All of the voxels within this central core, including those comprised of voids and inclusions, are included in the statistics. We then calculated the mean value, standard deviation and entropy for (a) the four image segments and for (b) their digital gradient images. (A digital gradient image of a given image was obtained by taking the absolute value of the difference between the initial image and that same image offset by one voxel horizontally, parallel to the rows of the x-ray detector array.) The statistics of the initial image of LAC values are called 'first order statistics;' those of the gradient image, 'second order statistics.'

99 GENERAL AND MISCELLANEOUS↗

The MAJORANA DEMONSTRATOR search for neutrinoless double beta decay

The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an ultra-low background, modular, HPGe detector array with a mass of 44.8-kg (29.7 kg enriched -88% in 76Ge) to search for neutrinoless double beta decay in 76Ge. The next generation of tonnescale Ge-based neutrinoless double beta decay searches will probe the neutrino mass scale in the inverted-hierarchy region. The MAJORANA DEMONSTRATOR is envisioned to demonstrate a path forward to achieve a background rate at or below 1 count/tonne/year in the 4 keV region of interest around the Q-value of 2039 keV. The MAJORANA DEMONSTRATOR follows a modular implementation to be easily scalable to the next generation experiment. First data taken with the DEMONSTRATOR are introduced here.

Cuesta Soria, Clara↗

Longitudinal Solid P Longitudinal Solid Polarized Target for CL get for CLAS12 and Study of Spin AS12 and Study of Spin Structure of Nucleons

A suite of experiments measuring target-spin observables in electron-nucleon scattering (dubbed Run Group C) was conducted at Jefferson Lab's Hall B in Newport News, VA with a new polarized nuclear target known as 'APOLLO' (Ammonia POLarized LOngitudinally). This innovative target is engineered to seamlessly integrate with the advanced 12GeV CEBAF (Continuous Electron Beam Accelerator Facility) accelerator and the Hall B CLAS12 (12 GeV CEBAF Large Acceptance Spectrometer) detector array. The 'APOLLO' target harnesses the power of Dynamic Nuclear Polarization (DNP) to achieve longitudinal polarization of solid ammonia, thereby creating a net polarization in both protons (NH3) and deuterons (ND3). These samples are subjected to a 5 Tesla magnetic field produced by the CLAS12 spectrometer central solenoid, cooled to 1 K using helium evaporation, and subsequently exposed to microwave radiation at a frequency of 140 GHz. This project was made possible through a collaborative partnership between the Jefferson Lab Target Group, Old Dominion University, University of Virginia, Christopher Newport University, and the CLAS Collaboration. Integrating the APOLLO target into CLAS12 presented unique challenges because of its specific spatial and dimensional constraints. This dissertation will highlight the innovative solutions developed to address these challenges, including the creation of a new target material transport system, the incorporation of superconducting magnetic correction coils, and the development of a customized Nuclear Magnetic Resonance (NMR) system. In addition to a detailed description of the development and operation of APOLLO, and an overview of RGC, this document also describes the global data fitting of proton asymmetries in the Deep Inelastic scattering (DIS) and the Resonance regions, and it offers insights into the comprehensive analysis of target polarization data.

Pandey, Pushpa↗

Case Study of High-Throughput Drug Screening and Remote Data Collection for SARS-CoV-2 Main Protease by Using Serial Femtosecond X-ray Crystallography

Since early 2020, COVID-19 has grown to affect the lives of billions globally. A worldwide investigation has been ongoing for characterizing the virus and also for finding an effective drug and developing vaccines. As time has been of the essence, a crucial part of this research has been drug repurposing; therefore, confirmation of in silico drug screening studies have been carried out for this purpose. Here we demonstrated the possibility of screening a variety of drugs efficiently by leveraging a high data collection rate of 120 images/second with the new low-noise, high dynamic range ePix10k2M Pixel Array Detector installed at the Macromolecular Femtosecond Crystallography (MFX) instrument at the Linac Coherent Light Source (LCLS). The X-ray Free-Electron Laser (XFEL) is used for remote high-throughput data collection for drug repurposing of the main protease (Mpro) of SARS-CoV-2 at ambient temperature with mitigated X-ray radiation damage. We obtained multiple structures soaked with nine drug candidate molecules in two crystal forms. Although our drug binding attempts failed, we successfully established a high-throughput Serial Femtosecond X-ray crystallographic (SFX) data collection protocol.

60 APPLIED LIFE SCIENCES↗

A versatile technique to enable sub-milli-Kelvin instrument stability for precise radial velocity measurements: tests with the habitable-zone planet finder

Insufficient instrument thermomechanical stability is one of the many roadblocks for achieving 10 cm s{sup −1} Doppler radial velocity precision, the precision needed to detect Earth-twins orbiting solar-type stars. Highly temperature and pressure stabilized spectrographs allow us to better calibrate out instrumental drifts, thereby helping in distinguishing instrumental noise from astrophysical stellar signals. We present the design and performance of the Environmental Control System (ECS) for the Habitable-zone Planet Finder (HPF), a high-resolution (R = 50,000) fiber-fed near-infrared (NIR) spectrograph for the 10 m Hobby–Eberly Telescope at McDonald Observatory. HPF will operate at 180 K, driven by the choice of an H2RG NIR detector array with a 1.7 μm cutoff. This ECS has demonstrated 0.6 mK rms stability over 15 days at both 180 and 300 K, and maintained high-quality vacuum (<10{sup −7} Torr) over months, during long-term stability tests conducted without a planned passive thermal enclosure surrounding the vacuum chamber. This control scheme is versatile and can be applied as a blueprint to stabilize future NIR and optical high-precision Doppler instruments over a wide temperature range from ∼77 K to elevated room temperatures. A similar ECS is being implemented to stabilize NEID, the NASA/NSF NN-EXPLORE spectrograph for the 3.5 m WIYN telescope at Kitt Peak, operating at 300 K. A [full SolidWorks 3D-CAD model] and a comprehensive parts list of the HPF ECS are included with this manuscript to facilitate the adaptation of this versatile environmental control scheme in the broader astronomical community.

79 ASTRONOMY AND ASTROPHYSICS↗

The Distribution of Ultrahigh-energy Cosmic Rays along the Supergalactic Plane Measured at the Pierre Auger Observatory

Ultrahigh-energy cosmic rays are known to be mainly of extragalactic origin, and their propagation is limited by energy losses, so their arrival directions are expected to correlate with the large-scale structure of the local Universe. In this work, we investigate the possible presence of intermediate-scale excesses in the flux of the most energetic cosmic rays from the direction of the supergalactic plane region using events with energies above 20 EeV recorded with the surface detector array of the Pierre Auger Observatory up to 2022 December 31, with a total exposure of 135,000 km 2 sr yr. The strongest indication for an excess that we find, with a posttrial significance of 3.1σ, is in the Centaurus region, as in our previous reports, and it extends down to lower energies than previously studied. We do not find any strong hints of excesses from any other region of the supergalactic plane at the same angular scale. In particular, our results do not confirm the reports by the Telescope Array Collaboration of excesses from two regions in the Northern Hemisphere at the edge of the field of view of the Pierre Auger Observatory. With a comparable integrated exposure over these regions, our results there are in good agreement with the expectations from an isotropic distribution.

Abdul Halim, A. [Univ. of Adelaide, SA (Australia)↗

Searching for resonances in the unbound 6Be nucleus using a radioactive 7Be beam

Knowledge of the 3He(3He,2p)4He reaction is important for understanding stellar burning and solar neutrino production. Previous measurements have found a surprisingly large rise in the cross section at low energies that could be due to a low energy resonance in the 3He + 3He (6Be) system or electron screening. In the 6Be nucleus, however, no excited states have been observed above the first 2+ state at Ex = 1:67 MeV up to 23 MeV, even though several are expected. The d(7Be,t)6Be reaction has been studied for the first time to search for resonances in the 6Be nucleus that may affect our understanding of the 3He(3He,2p)4He reaction. A 100-MeV radioactive 7Be beam from the Holifield Radioactive Ion Beam Facility (HRIBF) was used to bombard CD2 targets, and tritons were detected by the Silicon Detector Array (SIDAR). It appears that a combination of reaction mechanisms are necessary to explain the observed triton energy spectrum.

Chae, K. Y.↗

24 Mg(p, α) 21 Na reaction study for spectroscopy of 21 Na

The Mg-24(p, alpha)Na-21 reaction was measured at the Holifield Radioactive Ion Beam Facility at Oak Ridge National Laboratory in order to better constrain the spins and parities of the energy levels in Na-21 for the astrophysically important F-17(alpha, p)Ne-20 reaction rate calculation. 31-MeV proton beams from the 25-MV tandem accelerator and enriched Mg-24 solid targets were used. When recoiling He-4 particles from the Mg-24(p, alpha)Na-21 reaction we used a highly segmented silicon detector array to detect them; it measured the yields of He-4 particles over a range of angles simultaneously. A observed a new level at 6661 ± 5 keV in the present work. The extracted angular distributions for the first four levels of Na-21 and the results from distorted wave Born approximation (DWBA) calculations were compared to verify and extract the angular momentum transfer.

43 PARTICLE ACCELERATORS↗