Search NASA⌕ Search

SEARCH · Search NASA

Results for “building case study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Seamless Digital Environment – Plan for Data Analytics Use Case Study

The U.S Department of Energy Light Water Reactor Sustainability (LWRS) Program initiated research in to what is needed in order to provide a roadmap or model for Nuclear Power Plants to reference when building an architecture that can support the growing data supply and demand flowing through their networks. The Digital Architecture project published report Digital Architecture Planning Model (Oxstrand et. al, 2016) discusses things to consider when building an architecture to support the increasing needs and demands of data throughout the plant. Once the plant is able to support the data demands it still needs to be able to provide the data in an easy, quick and reliable method. A common method is to create a “one stop shop” application that a user can go to get all the data they need. The creation of this leads to the need of creating a Seamless Digital Environment (SDE) to integrate all the “siloed” data. An SDE is the desired perception that should be presented to users by gathering the data from any data source (e.g., legacy applications and work management systems) without effort by the user. The goal for FY16 was to complete a feasibility study for data mining and analytics for employing information from computer-based procedures enabled technologies for use in developing improved business analytics. The research team collaborated with multiple organizations to identify use cases or scenarios, which could be beneficial to investigate in a feasibility study. Many interesting potential use cases were identified throughout the FY16 activity. Unfortunately, due to factors out of the research team’s control, none of the studies were initiated this year. However, the insights gained and the relationships built with both PVNGS and NextAxiom will be valuable when moving forward with future research. During the 2016 annual Nuclear Information Technology Strategic Leadership (NITSL) group meeting it was identified would be very beneficial to the industry to support a research effort focused on data analytics. It was suggested that the effort would develop and evaluate use cases for data mining and analytics for employing information from plant sensors and database for use in developing improved business analytics.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal and electric multidomain dynamic model for integration of power grid distribution with behind-the-meter devices

As renewable energy sources like solar and wind power become more integrated into the grid, coordinated control of behind-the-meter devices is crucial for enhancing grid flexibility and reliability and for meeting cost targets, with standardized models being developed to support this transition. The increasing flexibility and uncertainty of integrated renewable energy grids, along with interactions between various subsystems, make traditional steady-state modeling insufficient to capture transient and dynamic behaviors. Current models (e.g., composite load and battery equivalent models) focus on thermodynamic or electrical characteristics but overlook critical electromechanical interactions. This limits the ability to share performance information for grid services and hampers fast dynamic simulations. In addition, motor stalling is usually triggered by a fault event and attributed to the characteristics of the mechanical torque of the motor, resulting in absorption of a large amount of reactive power during the stalling period. Further, this significant withdrawal of reactive power will deteriorate the dynamic voltage stability of power grids and cause delayed voltage recovery. Therefore, an in-depth modeling of the thermodynamics or mechanical torque is essential to study the impacts of the realistic torque characteristics of those behind-the-meter devices on power system voltage stability. This study developed a dynamic multidomain model for building HVAC systems, such as air-source heat pumps, to simulate their thermal and electrical responses to grid transients. The model can accurately predict power metrics with a mean absolute percentage error of 10%, by validating against with power system computer-aided design performance data. Case studies demonstrate the model capability of capturing the transient response to sudden voltage changes, rapid load fluctuations, and system shutdowns respectively. During a sudden voltage drop (30% for 0.1s), a fully loaded heat pump’s motor speed dropped, continued declining, and shut down after 3.6s, with severe power oscillations and a torque spike. A partially loaded unit experienced temporary oscillations but stabilized. Under higher building loads, compressor speed increased from 64% to 100%, with power and torque rising before stabilizing. In safety-triggered shutdowns, power decreased after minor fluctuations, and torque briefly spiked before dropping to zero.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An agent-based approach to study the diffusion rate and the effect of policies on joint placement of photovoltaic panels and green roof under climate change uncertainty

As two of the highest trending green technologies, photovoltaic panels and green roofs are proven to be effective practices for energy generation and energy saving. The achievable impact from the widespread installation of such technologies is, however, not clearly established. This is mainly because the degree of this impact highly depends on the inherently uncertain environmental and climate factors, as well as the unknown adoption rates of these technologies, which in turn depend on different characteristics of decision makers and interactions among them. To that end, this study aims to investigate the diffusion rate of these green technologies under uncertainties caused by climate change, characteristics of adopters, and their interactions. An integrated framework is developed to capture the interplay between financial and attitudinal aspects, as well as the uncertainties due to both the stochastic nature of system parameters and the interactions among agents involving human beings. Specifically, this framework consists of a integer programming model to optimize the green roof and/or photovoltaic panel installation settings for a given building under climate change uncertainty, and an agent-based model to factor in the role of human behavior and interactions. A case study for the city of Knoxville, TN, is presented to evaluate the effects of different policies on the diffusion rate of the green technologies of interest. The results show that the affordability of green technologies and public awareness are the key drivers of the adoption of these technologies, which highlight the important role of the decision makers in impacting the diffusion rate.

14 SOLAR ENERGY↗

DOE Climate Change Vulnerability and Adaptation Planning: Three Relevant Case Studies - 16056

Executive Order 13653, Preparing the United States for the Impacts of Climate Change, was issued in 2013. The President emphasized the importance for federal agencies to take action to enhance climate preparedness and resilience. The U.S. Department of Energy released the DOE Climate Change Adaptation Plan in 2014 to build resilience and mitigation across the Department, and to assure inclusion of climate change adaptation as part of its planning and operations. DOE's Office of Environmental Management has an important mission to manage safe cleanup of environmental legacy contamination brought about from five decades of nuclear weapons development and government sponsored nuclear energy research. Specifically, Environmental Management is responsible for remediation of soil and groundwater, deactivation and decommissioning of facilities, and disposal of hazardous and radioactive waste. Three case studies are discussed in this paper that demonstrate the cost benefit and importance for Environmental Management to assess climate change vulnerability and implement planning procedures: 1. Los Alamos National Laboratory in New Mexico has experienced $0.5 billion in unanticipated costs as a result of climate-related events including: extreme drought, wildfires, deluge rains, and historic flooding over the past 15 years. 2. The U.S. Environmental Protection Agency American Cyanamid Superfund Site, situated on the New Jersey coast was hit by Hurricane Irene in 2011. Three major contaminated, solvent impoundment berms were breached within the 100-year flood plain, causing major damage to the facility. 3. For radioactive waste disposal facilities in low-lying areas in proximity to groundwater, climate change vulnerability and assessment is prudent for operational management. One such Superfund hazardous and radioactive waste disposal facility, the Environmental Management Waste Management Facility located at the DOE Oak Ridge Reservation in Tennessee, has documented surface and ground water management challenges since construction began in 2001, driven by changing regional weather patterns. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An approach for fast and accurate simulation of phase change material based thermal energy storage in buildings

Latent heat thermal energy storage (LHTES) has significant potential for mitigating peak electricity demand and enabling load shifting in buildings. Phase Change Material embedded heat exchangers (PCM-HX) can significantly improve energy demand management due to high storage capacity. However, PCM-HX evaluation typically depends on computationally expensive fully transient simulations, posing significant challenges for scalable system- and building-level energy assessments across different climates and system architectures. This paper presents a generalized, accurate, and computationally efficient methodology for simulating building energy systems integrated with LHTES. The PCM-HX transient performance is represented by performance maps generated using a Generalized Resistance-Capacitance Model (GRCM) that enables accurate predictions of arbitrary PCM-HXs at low computational cost. The feasibility of the proposed approach was verified using a case study considering a dual-mode heat pump-thermal energy storage (HP-TES) system simulated in Modelica with Spawn of EnergyPlus™ for a DOE prototype small office building in two locations: Tampa, FL, and International Falls, MN. The PCM-HX performance maps provided accurate predictions of PCM-HX transient behavior, with mean absolute percentage deviations within 2–4% compared to GRCM while also achieving at least 1800× reduction in computational time. Moreover, the HP-TES system achieved energy savings of up to 17.4% in Tampa, FL, and 62.2% in International Falls, MN, demonstrating the broader applicability of the proposed methodology across different climate zones. This work highlights the importance of robust PCM-HX models in enabling accurate and computationally efficient building-level simulations and enabling future research opportunities for investigating optimized HP-TES designs and advanced control strategies for grid-interactive buildings.

Modelica↗

Exploring Grid-Interactive Efficient Building Strategies for Laboratories Through Energy Modeling

Laboratories are often overlooked in demand flexibility research due to constraints on their operations as mission critical facilities, despite the major role they play in an organization's emissions. Laboratories consume 3-4 times more energy than a typical office building and are commonly the largest energy users on any campus. Consequently, most laboratories in the United States are significant contributors to their organization's carbon footprint if their energy needs are met through the combustion of fossil fuels. As part of the initiative to decarbonize laboratories, this report documents an analysis on specifically grid-interactive efficient building (GEB) opportunities for reducing energy costs and emissions associated with laboratory operations. The goal of this initiative was to provide a case study and guidance on how to use OpenStudio and REopt as modeling tools for GEB technologies and strategies in laboratory environments across different climate zones in the United States. The analysis found that efficiency-based GEB strategies had the most significant impact on laboratory operations, while load-shedding and load-shifting GEB strategies produced smaller results. The culmination of these approaches applied across all five climate zones generated on average: 1) 28% energy cost savings and 30% greenhouse gas (GHG) emissions reductions, and 2) 4% enhanced energy cost savings under a time-of-use (TOU) pricing schedule compared to traditional pricing schemes. Grid-interactive efficiency building measures were found to produce the greatest energy savings in both electricity and natural gas, particularly in regions with high electrical loads, such as warm climates for cooling. Laboratories that had high levels of natural gas consumption, meanwhile, experienced the greatest emission reductions. The report concludes with an analysis on the opportunities for flexible loads in lab spaces and how small-scale measures in addition to opaque pricing structures for peak demand could become barriers to demand flexibility planning. The report also explores how electrifying laboratory buildings with heat pumps could reduce energy costs and GHG emissions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating an Exterior Insulation and Finish System for Deep Energy Retrofits

This report provides a case study of a deep energy retrofit using a site-applied exterior insulation and finish system (EIFS). Prefabricated EIFS panels are also discussed as a potential wall insulation retrofit solution. EIFSs are common in new and retrofit commercial construction. Such products typically consist of five layers installed over the top of a water resistive barrier as follows: (1) Adhesive (2) Foam insulation (3) Base coat (4) Reinforcing mesh embedded in the base coat (5) Top or finish coat. They can be applied to new or existing buildings that employ wood or masonry construction, and can utilize an insulation thickness of up to 16 in. However, such systems are rarely used in lowrise residential retrofits. Reasons for this might include a lack of demand for or knowledge of the systems in residential retrofit industry, high cost, and/or lack of suitable distribution channels serving the residential market. While the final appearance of an EIFS installation resembles stucco, it is a distinctly different system. Stucco is a generic cementitious-based material, whereas EIFSs are proprietary synthetic formulations distributed by manufacturers to a network of authorized applicators. An EIFS is composed of polymeric (organic) bonded aggregate and cement reinforced with a glass mesh. Stucco is made of inorganic cement, sand, and lime. In this project, a home was retrofitted using a site-applied 4-in.-thick EIFS. Site-specific details were developed as required for the residential retrofit application. Site work and the costs of the EIFS were documented. The case study home was modeled using version 2 of the National Renewable Energy Laboratory-developed Building Energy Optimization (BEopt) energy and cost analysis software. While a package utilizing the 4-in. EIFS is the optimal retrofit of the options analyzed in terms of annualized energy-related costs, it is higher cost than replacing the siding with midrange vinyl alone. However, compared to high-end vinyl, the EIFS package has a lower annualized energy cost. This held true for both the Islip, New York (climate zone 4) and Boston (climate zone 5) case studies. The report discusses the risks, selection criteria, interactions with other building systems, cost, performance, and other aspects of using an EIFS in a deep energy retrofit. EIFSs do not require special site safety precautions beyond general construction site precautions. Moisture design is important. Trapping moisture between two vapor/air barriers is a risk of all wall systems, including EIFS cladding applications if an interior vapor barrier exists and if there is not adequate ventilation through the drainage plane behind the insulation layer. Face-sealed approaches that rely on exposed sealants do not provide acceptable rain control or durability and are very risky. Generally, fire codes permit EIFSs for most building types and conditions.

airtightness↗

U.S. Building Stock Characterization Study: A National Typology for Decarbonizing U.S. Buildings

To support the U.S. Department of Energy’s (DOE) Advanced Building Construction (ABC) Collaborative, the National Renewable Energy Laboratory (NREL) has been tasked with characterizing the U.S. building stock and developing a national typology of buildings. The potential use cases of such a typology are flexible and evolving, but in this initial phase, the primary intention is to help identify technology requirements and engineering solutions for moving the U.S. building stock toward a zero-carbon future by midcentury. This study was developed by NREL, with input from the ABC Analysis Working Group, which is a subset of the ABC Collaborative led by the Rocky Mountain Institute (RMI).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

New Whole-House Solutions Case Study: Meeting DOE Challenge Home Program Certification - Chicago, IL; Denver, CO; Devens, MA

In this project, three production home builders—K. Hovnanian Homes, David Weekley Homes, and Transformations, Inc.—partnered with Building America team Building Science Corporation to evaluate the certification of five test homes to the new DOE Challenge Home program performance standard (now DOE Zero Energy Ready Home program). The builders identified key benefits and barriers that impacted the certification of the test homes, and the likelihood of whether DOE Challenge Home certification would be pursued in future homes

BSC↗

Improved turbopump dynamics

A study was initiated to investigate the practicality of increasing rotor critical speeds by changes in manufacturing method. The technique would be to build a pump with an all laser welded shaft and case; such unit to be opened by laser cutting and rebuilt by rewelding the same surface. Use of a split casing, common in industry, would permit assembly of the rotor outside the case. A team was formed to perform the study; however, the work of the team was severely restricted by conflict with higher priority tasks. No manpower was available to evaluate alternate configurations. Thus, much of the synergetic effects of cohesive design modification was lost. Although very limited results were achieved, nothing was found to indicate that the method is not worth further investigation.

Kiefling, L.↗

Distribution Grid Impact Study in Highland Park, Michigan: Understanding Rooftop Solar, Behind-the-Meter Energy Storage, Electric Vehicle Charging, and Building Electrification [Slides]

Through the Communities LEAP (Local Energy Action Program) Pilot, the National Renewable Energy Laboratory (NREL) engaged the Highland Park Stakeholder Coalition to scope four technical assistance work areas to address their energy needs and goals. This slide deck addresses the highlighted tasks under work area "B" related to policy analysis, due diligence, and case studies for removing barriers and providing best practices for local clean energy development. Highland Park community members face frequent, long-duration power interruptions due largely to the aging distribution system serving the area and the legacy design standards used in its construction. While degrading physical infrastructure such as poles, crossarms, and transformers can result in this substandard reliability, another notable characteristic of this legacy system is the lower, 4.8 kV, voltage class. This is a legacy construction standard which many utilities, DTE included, are phasing out in favor of higher, 15 or 25 kV, voltage classes instead. The existing 4.8 kV distribution system serving Highland Park may limit significant adoptions of clean-energy technologies like high percentages of building electrification or electric vehicle adoption. The following analysis seeks to quantify these limitations under a variety of clean-energy technology adoption scenarios. It compares the overall system risks of the present system to those of a hypothetical, upgraded 13.2 kV system, using NREL-developed risk metrics and offers upgrade cost considerations. The legacy 4.8 kV voltage class serving Highland park is not, as we have modeled it, a major limitation to the widespread adoption of cost-optimal rooftop solar and/or behind-the-meter energy storage. Within our modeling framework, these technologies namely impact secondary, low-voltage assets, which may be remedied without the need for a system-wide upgrade to a 13.2 kV voltage class. Our model of the current 4.8kV system indicates it is not capable of supporting community-wide electrification efforts. Widespread building electrification, and the resulting large increase in wintertime load, dramatically increases the prevalence of voltage violations and thermal overloading on the current 4.8 kV distribution system. These impacts illustrate the need for system-wide upgrades to a 13.2 kV voltage class to accommodate these technologies. Low to Moderate DER adoption does not adversely impact the grid but does improve undervoltage and asset overloading issues. However, these benefits are insufficient to defer grid upgrades. Higher DER penetration is shown to increase overvoltage and asset overloading in future electrification scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Nevada National Security Site (NNSS) Environmental Remediation Using EPA's Model Evaluation Guidance to Move to Closure - 15588

The National Nuclear Security Administration Nevada Field Office (NNSA/NFO) has adapted the Environmental Protection Agency's guidance on environmental model evaluation as a framework for evaluating corrective action investigation models. Model evaluation is an important confidence building activity, which is needed to support closure of the Nevada National Security Site (NNSS) Corrective Action Units (CAUs) associated with underground nuclear testing. Through this process, site-investigation models of groundwater flow and contaminant transport are reviewed and compared to new site-specific data to determine if the results can be used to support regulatory decisions required for closure and to achieve NNSA/NFO site management objectives. The regulatory decisions include identifying and establishing CAU regulatory boundaries; identifying institutional controls, including use-restriction boundaries; and developing a long-term closure monitoring program. A successful case study from Frenchman Flat, Nevada is used to illustrate the model evaluation process. Groundwater flow and transport from two of the 10 underground nuclear tests in Frenchman Flat had the largest potential for contaminating groundwater, and were selected for evaluation. Wells were drilled, logged, hydraulically tested, sampled, and analyzed for radionuclides and the data was evaluated with respect to previous site conceptualization and numerical model results. The approach and results of this process as applied to the PIN STRIPE test and how it helped build confidence to close the Frenchman Flat CAU is described in this case study. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Toward initial conditions of conserved charges. Part I. Spatial correlations of quarks and antiquarks

In this work, we study the spatial correlations among quarks and antiquarks produced at mid-rapidity by gluon pair production in the color glass condensate framework. This paper is the first part of a series in which we calculate a complete set of quark/quark, quark/antiquark, and antiquark/antiquark spatial correlation functions in heavy-light ion collisions, with the goal of incorporating their conserved charges into the initial conditions of hydrodynamics. The physical mechanisms captured in this calculation include geometric, entanglement, and interaction-mediated correlations. In this first paper, we construct the building blocks for the correlations arising from single- and double-pair production, studying in detail the single-pair case and the general features of the double-pair case. We find a rich correlation structure in transverse coordinate space, with different mechanisms dominating over different length scales, and we present explicit results for the quark-antiquark correlations in the single-pair production regime. We reserve a detailed discussion of the double-pair production regime for the next paper in this sequence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

WearGP: A computationally efficient machine learning framework for local erosive wear predictions via nodal Gaussian processes

Computational fluid dynamics (CFD)-based wear predictions are computationally expensive to evaluate, even with a high-performance computing infrastructure. Thus, it is difficult to provide accurate local wear predictions in a timely manner. Data-driven approaches provide a more computationally efficient way to approximate the CFD wear predictions without running the actual CFD wear models. In this paper, a machine learning (ML) approach, termed WearGP, is presented to approximate the 3D local wear predictions, using numerical wear predictions from steady-state CFD simulations as training and testing datasets. The proposed framework is built on Gaussian process (GP) and utilized to predict wear in a much shorter time. The WearGP framework can be segmented into three stages. At the first stage, the training dataset is built by using a number of CFD simulations in the order of O (10 2 ). At the second stage, the data cleansing and data mining process are performed, where the nodal wear solutions are extracted from the solution database to build a training dataset. At the third stage, the wear predictions are made, using trained GP processes. Two CFD case studies including 3D slurry pump impeller and casing are used to demonstrate the WearGP framework, in which 144 training and 40 testing data points are used to train and test the proposed method, respectively. The numerical accuracy, computational effiency and effectiveness between the WearGP framework and CFD wear model for both slurry pump impellers and casings are compared. It is shown that the WearGP framework can achieve highly accurate results that are comparable with the CFD results, with a relatively small size training dataset, with a computational time reduction in an order of 10 5 to 10 6 .

42 ENGINEERING↗

A simple method for understanding the triangular growth patterns of transition metal dichalcogenide sheets

Triangular nanoflake growth patterns have been commonly observed in synthesis of transition metal dichalcogenide sheets and their hybrid structures. Triangular nanoflakes not only show exceptional properties, but also can serve as building blocks for two or three dimensional structures. In this study, taking the MoS{sub 2} system as a test case, we propose a Matrix method to understand the mechanism of such unique growth pattern. Nanoflakes with different edge types are mathematically described with configuration matrices, and the total formation energy is calculated as the sum of the edge formation energies and the chemical potentials of sulfur and molybdenum. Based on energetics, we find that three triangular patterns with the different edge configurations are energetically more favorable in different ranges of the chemical potential of sulfur, which are in good agreement with experimental observations. Our algorithm has high efficiency and can deal with nanoflakes in microns which are beyond the ability of ab-initio method. This study not only elucidates the mechanism of triangular nanoflake growth patterns in experiment, but also provides a clue to control the geometric configurations in synthesis.

36 MATERIALS SCIENCE↗

Fault detection and analysis in nuclear research facility using artificial intelligence methods

In this article, an online detection of transducer and actuator condition is discussed. A case study is on the reading of area radiation monitor (ARM) installed at the chimney of PUSPATI TRIGA nuclear reactor building, located at Bangi, Malaysia. There are at least five categories of abnormal ARM reading that could happen during the transducer failure, namely either the reading becomes very high, or very low/ zero, or with high fluctuation and noise. Moreover, the reading may be significantly higher or significantly lower as compared to the normal reading. An artificial neural network (ANN) and adaptive neuro-fuzzy inference system (ANFIS) are good methods for modeling this plant dynamics. The failure of equipment is based on ARM reading so it is then to compare with the estimated ARM data from ANN/ ANFIS function. The failure categories in either ‘yes’ or ‘no’ state are obtained from a comparison between the actual online data and the estimated output from ANN/ ANFIS function. It is found that this system design can correctly report the condition of ARM equipment in a simulated environment and later be implemented for online monitoring. This approach can also be extended to other transducers, such as the temperature profile of reactor core and also to include other critical actuator conditions such as the valves and pumps in the reactor facility provided that the failure symptoms are clearly defined.

42 ENGINEERING↗