Search NASA⌕ Search

SEARCH · Search NASA

Results for “cold”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Energy and Exergy Analysis of Low-Global Warming Potential Refrigerants as Replacement for R410A in Two-Speed Heat Pumps for Cold Climates

Heat pumps (HPs) are being developed with a new emphasis on cold climates. To lower the environmental impact of greenhouse gas (GHG) emissions, alternate low global warming potential (GWP) refrigerants must also replace the exclusive use of the refrigerant R410A, preferably without re-engineering the mechanical hardware. In this paper, we analyze the performance of four low-GWP alternative refrigerants (R32, R452B, R454B, and R466A) relative to the conventional R410A and draw conclusions on the relative performances for providing heating in cold climates based on the Air-Conditioning, Heating, and Refrigeration Institute (AHRI) 210/240 standard for two-speed heat pumps. The simulations are carried using the Department of Energy, Oak Ridge National Laboratory (DOE/ORNL) Heat Pump Design Model (HPDM), a well-known heating, ventilation, and air conditioning (HVAC) modeling and design tool in the public domain and the HVAC research and development community. The results of the simulation are further scrutinized using exergy analysis to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate low-GWP refrigerants to replace R410A using available compressors and system components, without compromising performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mechanical and Tribological Performance of Additively Manufactured Nanocrystalline Aluminum via Cryomilling and Cold Spray

In this study, nanocrystalline (NC) aluminum (Al) and magnesium (Mg)-doped Al bulk components were fabricated using a hybrid manufacturing process that combines cryomilling and high-pressure cold spray (HPCS) additive deposition techniques. Yttria-stabilized zirconia (YSZ) was also added during the HPCS process to improve deposition efficiency and build-up thickness via peening. The evolution of morphology, crystallite size, and elemental composition of both cryomilled powders and cold-sprayed (CS’ed) components was systematically characterized using X-ray Diffraction (XRD), Scanning Electron Microscopy (SEM), and Transmission Electron Microscopy (TEM). Mechanical characterization was performed using Vickers microhardness and uniaxial tensile testing, while the tribological behavior was assessed using sliding wear tests under dry/lubricated conditions. XRD analysis revealed that increased cryomilling duration led to significant crystallite refinement, which directly correlated with enhanced hardness and strength. This mechanical strengthening was accompanied by an increase in coefficient of friction (COF) and lower wear rates. The results also showed that the Mg-doped Al exhibited superior hardness, tensile strength, and tribological performance compared to pure Al. The study further explores the underlying mechanisms responsible for these enhancements, highlighting the potential of solute-assisted grain boundary stabilization in tailoring high-performance NC Al alloys.

36 MATERIALS SCIENCE↗

Aerosol size distribution properties associated with cold-air outbreaks in the Norwegian Arctic

The aerosol particles serving as cloud condensation and ice nuclei contribute to key cloud processes associated with cold-air outbreak (CAO) events but are poorly constrained in climate models due to sparse observations. Here we retrieve aerosol number size distribution modes from measurements at Andenes, Norway, during the Cold-Air Outbreaks in the Marine Boundary Layer Experiment (COMBLE) and at Zeppelin Observatory, approximately 1000 km upwind from Andenes at Svalbard. During CAO events at Andenes, the sea-spray-mode number concentration is correlated with strong over-ocean winds with a mean of 8±4 cm −3 that is 71 % higher than during non-CAO conditions. Additionally, during CAO events at Andenes, the mean Hoppel minimum diameter is 6 nm smaller than during non-CAO conditions, though the estimated supersaturation is lower, and the mean number concentration of particles that likely activated in-cloud is 109±61 cm −3 with no statistically significant difference from the non-CAO mean of 99±66 cm −3 . For CAO trajectories between Zeppelin Observatory and Andenes, the upwind-to-downwind change in number concentration is the largest for the accumulation mode with a mean decrease of 93±95 cm −3 , likely attributable primarily to precipitation scavenging. These characteristic properties of aerosol number size distributions during CAO events provide guidance for evaluating CAO aerosol–cloud interaction processes in models.

54 ENVIRONMENTAL SCIENCES↗

Lunar Cold Trap Contamination by Landing Vehicles

Tools have been developed to model and simulate the effects of lunar landing vehicles on the lunar environment (Metzger, 2011), mostly addressing the effects of regolith erosion by rocket plumes and the fate of the ejected lunar soil particles (Metzger, 2010). These tools are being applied at KSC to predict ejecta from the upcoming Google Lunar X-Prize Landers and how they may damage the historic Apollo landing sites. The emerging interest in lunar mining poses a threat of contamination to pristine craters at the lunar poles, which act as "cold traps" for water and may harbor other valuable minerals Crider and Vondrak (2002). The KSC Granular Mechanics and Regolith Operations Lab tools have been expanded to address the probability for contamination of these pristine "cold trap" craters.

Lunar↗

Characterization of Low Pressure Cold Plasma in the Cleaning of Contaminated Surfaces

The characterization of low pressure cold plasma is a broad topic which would benefit many different applications involving such plasma. The characterization described in this paper focuses on cold plasma used as a medium in cleaning and disinfection applications. Optical Emission Spectroscopy (OES) and Mass Spectrometry (MS) are the two analytical methods used in this paper to characterize the plasma. OES analyzes molecules in the plasma phase by displaying the light emitted by the plasma molecules on a graph of wavelength vs. intensity. OES was most useful in identifying species which may interact with other molecules in the plasma, such as atomic oxygen or hydroxide radicals. Extracting useful data from the MS is done by filtering out the peaks generated by expected molecules and looking for peaks caused by foreign ones leaving the plasma chamber. This paper describes the efforts at setting up and testing these methods in order to accurately and effectively characterize the plasma.

cold plasma characterization↗

Carbon Monoxide in the Cold Debris of Supernova 1987A

We report spectroscopic and imaging observations of rotational transitions of cold CO and SiO in the ejecta of SN1987A, the first such emission detected in a supernova remnant. In addition to line luminosities for the CO J = 1-0, 2-1, 6-5, and 7-6 transitions, we present upper limits for all other transitions up to J = 13-12, collectively measured from the Atacama Large Millimeter Array, the Atacama Pathfinder EXperiment, and the Herschel Spectral and Photometric Imaging REceiver. Simple models show the lines are emitted from at least 0.01 M ☉ of CO at a temperature >14 K, confined within at most 35% of a spherical volume expanding at ~2000 km s-1. Moreover, we locate the emission within 1'' of the central debris. These observations, along with a partial observation of SiO, confirm the presence of cold molecular gas within supernova remnants and provide insight into the physical conditions and chemical processes in the ejecta. Furthermore, we demonstrate the powerful new window into supernova ejecta offered by submillimeter observations.

Cold↗

The Interaction Between Boundary Layer and Convection Schemes in a WRF Simulation of Post‐Cold‐Frontal Clouds over the ARM East North Atlantic Site

The correct representation of lowlevel midlatitude clouds found in the wake of cold fronts strongly relies on the representation of planetary boundary layer (PBL) and convection processes, which are typically parameterized separately in numerical models. Using the Weather Research and Forecasting Model (WRF), this study investigates how distinct pairs of PBL and convection parameterization schemes represent cloud fraction in the postcoldfrontal region. The simulations focus on the region of the DOEARM Eastern North Atlantic observation site in the Azores Islands in the wake of a cold front that passed on December 25, 2015. Different PBL and convection schemes are combined to create 12 distinct configurations. The main differences between the selected physical parameterizations are the strength of vertical mixing and the entrainment. The simulations produce a wide range of cloud fractions, where some configurations significantly underestimate while others clearly overestimate satellite and surfacebased estimates of cloud fraction. A skill score is used to quantitatively assess the performance of each configuration with respect to groundbased radar data. The key processes that are found to significantly impact the cloud fraction distribution are the strength of the PBL decoupling, the vertical wind shear, entrainment and detrainment rates in shallow convection and the occurrence of drizzle. This indicates that to successfully simulate postcoldfrontal clouds, modeled physics must balance strong internal vertical mixing and weak exchange with the free troposphere. For this case study, cloud fraction was more sensitive to the choice of convection scheme than PBL scheme.

moist convection interaction between parameterizat↗

How strong is ocean mixing in the Pacific Ocean cold tongue, and does it matter?

Microstructure observations within the Pacific Ocean cold tongue reveal that strong surface boundary layer turbulence often penetrates into the thermocline producing hundreds of W/m^2 of downward heat transport during nighttime and early morning. Hence, it has been suggested that ocean turbulent mixing contributes significantly to the sea-surface temperature budget and modulates air-sea interaction on a wide range of timescales with consequences for global climate and weather. However, most observations of ocean microstructure in the cold tongue are from 0 N,140 W. In this presentation, I will attempt to characterize ocean mixing at and beyond 0 N,140 W using models. Questions to be addressed include: 1) can we model ocean mixing at 0 N,140 W? And 2) how does ocean mixing vary in space and time beyond 0 N,140 W? Finally, 3) how does ocean mixing compare to the air-sea heat flux in the sea-surface temperature budget? Results will be derived from existing observations at 0 N, 140 W and a new hierarchy of regional ocean process simulations including a 20-year-long submesoscale-permitting regional model and month-long turbulence-permitting large eddy simulations embedded in a regional model.

Strong↗

The Impact of Dry Intrusions on Midlatitude Cold-Air Outbreak Cloud Transitions

Cold-air outbreaks (CAOs) form marine boundary layer (MBL) clouds that undergo rapid overcast-to-broken cloud regime transitions, initiated by substantial rain. CAOs are usually accompanied by dry intrusions (DIs) that subside as free-tropospheric (FT) air into the postfrontal sector of mid-latitude storms. For an exemplary cold-air outbreak in the NW Atlantic that showed faster transitions (corresponding to reduced extents of overcast clouds) closer to the low-pressure system, we posit that varying transitions are caused by an uneven meteorological pattern imposed by the prevailing DI. We compile satellite observations, reanalysis fields, and Lagrangian large-eddy simulations (LES) translating along MERRA2-based trajectories to show that postfrontal trajectories closer to the low-pressure system are uniquely favorable to rain formation (and, thus, cloud transitions) as they show (1) weaker FT subsidence rates, (2) greater FT humidity, (3) greater MBL windspeeds, and (4) a colder MBL as well as reduced lower-tropospheric stability. We present an updated conceptual view of postfrontal cloud formation that may guide future investigations.

Cold-air outbreaks↗

Design and Hardware Progress on a Magnetically-Geared Actuator for Extremely Cold Lunar Environments

Introduction: Under the Motors for Dusty and Extremely Cold Environments (MDECE) Project, NASA Glenn Research Center is developing a magnetically-geared actuator for extremely cold space environments to avoid the wiring and significant efficiency penalty associated with heating grease-lubricated actuators as well as the stringent life and loading constraints imposed by dry film lubricated mechanical gears. The heating penalty can be equivalent to up to a 90% efficiency reduction in permanently shadowed regions on the Moon. This poster or presentation will summarize the progress made over the past 6-12 months on designing the fully-functional actuator and building a proof-of-concept actuator and testing it in an ambient environment. Design Progress: A critical design review was successfully completed at the end of June 2023. This presentation will touch on the key highlights from that review in the areas of electro-magnetic design and optimization, bearing optimization, thermal analysis, structural analysis, and mechanical design and manufacturing. The predicted technical performance measures of the actuator will be mentioned. The team is currently finishing some actions from the review and finalizing the drawing package in preparation for hardware procurement. Hardware Progress: Despite some significant delays in receiving fabricated parts and magnetic subassemblies, progress was made in manufacturing and assembling a proof-of-concept version of both the actuator’s magnetically-geared motor (Fig. 1) and the actuator’s cycloidal-type output magnetic gear stage (Fig. 2) [3]. The presentation will mention key lessons learned to date from the fabrication, assembly, and testing of the proof of concept.

Lunar surface↗

Aerosol Size Distribution Properties Associated With Cold-Air Outbreaks in the Norwegian Arctic

The aerosol particles serving as cloud condensation and ice nuclei contribute to key cloud processes associated with cold-air outbreak (CAO) events but are poorly constrained in climate models due to sparse observations. Here we retrieve aerosol number size distribution modes from measurements at Andenes, Norway, during the Cold-Air Outbreaks in the Marine Boundary Layer Experiment (COMBLE) and at Zeppelin Observatory, approximately 1000 km upwind from Andenes at Svalbard. During CAO events at Andenes, the sea-spray-mode number concentration is correlated with strong over-ocean winds with a mean of 8±4 cm−3 that is 71 % higher than during non-CAO conditions. Additionally, during CAO events at Andenes, the mean Hoppel minimum diameter is 6 nm smaller than during non-CAO conditions, though the estimated supersaturation is lower, and the mean number concentration of particles that likely activated in-cloud is 109±61 cm−3 with no statistically significant difference from the non-CAO mean of 99±66 cm−3. For CAO trajectories between Zeppelin Observatory and Andenes, the upwind-to-downwind change in number concentration is the largest for the accumulation mode with a mean decrease of 93±95 cm−3, likely attributable primarily to precipitation scavenging. These characteristic properties of aerosol number size distributions during CAO events provide guidance for evaluating CAO aerosol–cloud interaction processes in models.

accumulation mode particle scavenging↗

DEVELOPMENT OF COLD CLIMATE HEAT PUMP USING TWO-STAGE COMPRESSION

This paper uses a well-regarded, hardware based heat pump system model to investigate a two-stage economizing cycle for cold climate heat pump applications. The two-stage compression cycle has two variable-speed compressors. The high stage compressor was modelled using a compressor map, and the low stage compressor was experimentally studied using calorimeter testing. A single-stage heat pump system was modelled as the baseline. The system performance predictions are compared between the two-stage and single-stage systems. Special considerations for designing a cold climate heat pump are addressed at both the system and component levels.

Cold Climate↗

Mathematical modeling of cold cap: Effect of bubbling on melting rate

The rate of melting is a primary concern in the vitrification of radioactive wastes because it directly influences the life cycle of nuclear waste cleanup efforts. To increase glass melting performance, experimental and industrial all-electric waste glass melters employ various melt-rate enhancement techniques, the most prominent being the application of bubblers submerged into molten glass. This study investigates various ways in which bubbling affects melting rate in a waste glass melter. Using the recently developed cold cap model, we suggest that forced convection of molten glass, which increases the cold cap bottom temperature, is the main factor. Other effects, such as stirring the feed into molten glass or reducing the insulating effect of foaming, also play a role.

bubbling↗

Building America Case Study: Field Performance of Inverter-Driven Heat Pumps in Cold Climates - Connecticut, Massachusetts, and Vermont

New inverter-driven ASHPs are gaining ground in colder climates. These systems operate at sub-zero temperatures without the use of electric resistance backup. There are still uncertainties, however, about cold-climate capacity and efficiency in cold weather and questions such as measuring: power consumption, supply, return, and outdoor air temperatures, and air flow through the indoor fan coil. CARB observed a wide range of operating efficiencies and outputs from site to site. Maximum capacities were found to be generally in line with manufacturer's claims as outdoor temperatures fell to -10 degrees F. The reasons for the wide range in heating performance likely include: low indoor air flow rates, poor placement of outdoor units, relatively high return air temperatures, thermostat set back, integration with existing heating systems, and occupants limiting indoor fan speed. Even with lower efficiencies than published in other studies, most of the heat pumps here still provide heat at lower cost than oil, propane, or certainly electric resistance systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of SCC Initiation Precursors in Cold-Worked Alloy 690

Due to its superior resistance to corrosion and stress corrosion cracking (SCC), high Cr, Ni-base Alloy 690 is now commonly used in pressurized water reactors (PWRs). Even though highly cold-worked (CW) Alloy 690 has been shown to be susceptible to SCC crack growth in PWR primary water environments, an open question remains whether SCC initiation was possible for these materials under constant load test conditions. Testing has been performed on a series of CW alloy 690 CRDM tubing specimens at constant load for up to 9,220 hours in 360°C simulated PWR primary water. A companion paper will discuss the overall testing approach and describe results on different alloy 690 heats and cold work levels. The focus of the current paper is to illustrate the use of focused ion beam (FIB), scanning electron microscopy (SEM) and transmission electron microscopy (TEM) for the high-resolution investigation of precursor damage and intergranular (IG) crack nucleation in these specimens. Three-dimensional (3D) FIB/SEM imaging has been conducted on a series of grain boundary (GB) damage precursors, such as IG small cavities, local corrosion and even shallow cracks observed at the specimen surface. Contrast variations and EDS mapping were used to distinguish oxides, carbides and cavities from the matrix material. Nanometer-sized cavities were observed associated with GB carbides in the highly CW specimens. Shallow IG cracks were present in the 30%CW specimens and exhibited oxidized crack flanks and a higher density of cavities ahead of the oxide front in all cases. The shape and distribution of carbides and cavities in the plane of the cracked GBs was analyzed in 3D to gain a mechanistic understanding of the processes that may be leading to crack initiation in highly CW alloy 690.

3D FIB/SEM↗

Healthy Indoor Air Quality: A Guide to Understanding Pollutants in Extreme Cold Climates

Internal air quality management through commonly supported recommendations in extreme cold weather climates is complicated by cold air infiltration. Air filtration and IAQ monitoring, through central and stand-alone systems can improve internal air quality to the benefit of occupant health and safety. This fact sheet includes reference information for pollutants, sources, health effects, and mitigation strategies.

cold climate↗