Search NASA⌕ Search

SEARCH · Search NASA

Results for “commodity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

LEED: A Lightwave Energy-Efficient Datacenter

The Lightwave Energy-Efficient Datacenter (LEED) program is a disruptive “green-field” approach that provides a quantum leap in the energy efficiency of datacenters. LEED’s fundamental value proposition is that a novel and re-architected optical network—RotorNet— can deliver “more bandwidth per buck” as well as unique system-level attributes that significantly improve overall datacenter energy efficiency and performance. LEED has developed three system-level testbeds. The first testbed uses calibrated hardware and software power measurements to determine server energy efficiency as a function of network bandwidth and workload. These measurements have shown that increasing network communications bandwidth dramatically increases server energy efficiency providing a realistic path to the overall ENLITENED program goal of doubling the number of transactions per joule. The second testbed demonstrates key hardware: a prototype low-loss, high-port count optical “selector switch”. This switch was fabricated, racked, and tested. Measured switch characteristics include loss, bandwidth, crosstalk, switch time, system-level switch time (including the transceivers), and bit error rate. The third testbed demonstrates a fully working and manufactured pinwheel design which dramatically lowers the cost of design, while delivering high switch radix and low reconfiguration times. The LEED project has tied these three novel photonic switch prototypes together with production servers and software through the development of a novel FPGA-based NIC platform called Corundum. Corundum ensures that the packet-switched protocols supported by commodity operating systems and devices can interface with the Rotor switch design. The LEED group has used this combined hardware and software prototype to characterize applications running at a commercially relevant scale. The project has used a combination of enhanced optical modulation amplitude (OMA) modulators, broadband multiplexers and demultiplexers, avalanche photodiodes, and a novel burst-mode receivers to enable the insertion of LEED-developed optical switches without the need for expensive optical amplification. Our modeling has shown that measured LEED-developed device characteristics can achieve link characteristics of 2 pJ/bit including both transceivers and the Rotor switch. In summary, the LEED program has demonstrated a credible and practical path, through novel hardware and software, to realize the program objectives of ENLITENED. The net result will ensure that the United States maintains its strength in the crucial sector of Information Technology, which is vital to both our economic security and our national security.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving durability and performance of solid oxide electrolyzers by controlling surface composition on oxygen electrodes

Solid oxide electrolysis cell (SOEC) is a promising technology for high-efficiency energy conversion, enabling the production of hydrogen, syngas, synthetic fuels, and various commodity chemicals. Unlike traditional thermochemical processes, SOECs operate at elevated temperatures (600-850°C), benefiting from favorable thermodynamics and reaction kinetics. This makes them highly energy efficient compared to alkaline or polymer electrolyte membrane (PEM) electrolysis technologies. However, despite these advantages, SOECs face significant challenges related to performance degradation over time. A primary issue is the degradation of the oxygen electrode due to strontium (Sr) segregation and impurity poisoning from chromium (Cr) and sulfur (S). This is because the pathway to deposition of Cr and S include the reaction of Cr and S with the segregated SrO at the surface. Sr segregation leads to the formation of insulating compounds such as SrCrO4 and SrSO4, which block active sites, reduce oxygen exchange rates, and compromise the electrode's electrochemical stability. The degradation mechanisms involve complex interactions between the electrode material's surface chemistry, microstructure, and the operating environment. Sr segregation is particularly problematic because it facilitates the deposition of Cr and S impurities, exacerbating performance losses. Addressing these issues is critical to enhancing the durability and economic viability of SOEC technology. The primary goal of this project is to improve the durability and performance of SOECs by controlling the surface composition of the oxygen electrode. This is achieved by suppressing Sr segregation, thereby mitigating impurity poisoning pathways. The project aims to enhance the oxygen exchange rate, improve cell stability, and extend the operational lifespan of SOECs without necessitating major changes to electrode chemistry or stack components.

30 DIRECT ENERGY CONVERSION↗

Evaluation of Getters for Helium Purification

• Helium-3 is a vital commodity in both medical and defense applications • Ultra-low cryogenic coolant (MRI imaging, etc.) • Neutron detectors • Being investigated as possible fusion fuel • Managed and distributed by DOE-OS • New PDRD project exploring helium isotope separation • Limited supply • Only available from tritium decay • Prohibitively difficult to separate from helium-4 • SRS Tritium Facility provides a steady source

Angelette, Lucas M.↗

Core Model Proposal #: 374 Global Iron and Steel Trade

This core model proposal (CMP) enables GCAM to track the gross trade of regional iron and steel commodities. Following the logit-based Armington trade modeling framework, this CMP aims to improve the representation of physical output (Mt) flows in GCAM v6.0’s iron and steel sector. In addition, the core model proposal also updates the regional steel demand and improves the representation of iron and steel technologies (and their energy coefficients) across all GCAM regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Core Model Proposal #390: Base Year Update: Initial Updates Preparing for the New Base Year

GCAM's current base year – the last historical year used for calibration – 2015, is considerably lagged compared to the present year, indicating out-of-date assumptions about near-past state of the resources, commodities, and technologies represented in GCAM. This proposal makes data and code changes to enable updating the GCAM base year easier by making the processing code more flexible and robust.

97 MATHEMATICS AND COMPUTING↗

Core Model Proposal #389: Ammonia Trade and Miscellaneous GCAM 7.0 Bugfixes

This proposal re-structures the N fertilizer sector in the model, replacing the trade structure which was implemented before GCAM had the capability to trade secondary goods between regions, and re-naming the production commodity "ammonia" in order to better set up the model for representing ammonia as an energy carrier in subsequent work. Several bugfixes for GCAM 7.0 are also included in the proposal.

97 MATHEMATICS AND COMPUTING↗

ASU’s DAC polymer-enhanced cyanobacterial bioproductivity (AUDACity)

ASU’s DAC polymer-enhanced cyanobacterial bioproductivity (AUDACity) project aims to demonstrate a novel, scalable method for removing carbon dioxide (CO 2 ) directly from ambient air and delivering it to cyanobacterial cultures to produce commodity biofuel, mid-value protein for supplements, and high value phycocyanin (PC), a natural blue colorant (Figure A). This approach uses low-cost, reusable anion exchange polymers embedded in modular mesh packets, which capture CO 2 during drying cycles when exposed to ambient air, and release concentrated CO 2 into aqueous cultivation systems. The project addresses a critical challenge in energy research needed for developing sustainable, economically viable methods of Direct Air Capture (DAC) that can be integrated with bio-based systems for fuel and chemical production. AUDACity contributes to scientific understanding by integrating materials chemistry, cyanobacterial biology, and system engineering to create a distributed CO 2 delivery platform. Key insights have emerged around the design of biocompatible sorbents, optimization of CO 2 capture-release cycles, and durability of packet-based delivery systems under outdoor conditions. Notably, the team has synthesized and tested a range of polymer sorbents, identified mechanisms of material degradation and fouling, and advanced both lab- and pilot-scale cultivation systems to evaluate performance. From a technical and economic standpoint, AUDACity shows promise for achieving cost-effective CO 2 capture and delivery into aqueous media and biofuel production. Preliminary techno-economic analysis (TEA) indicates that the DAC system based on current performance can reach $\$$680/tonne CO 2 delivered into aqueous solution; with reasonable improvements to sorbent lifetime, sorbent capacity, reducing water uptake the approach could reach $\$$66/tonne by avoiding the need for energy-intensive sorbent regeneration and CO 2 compression, making it more feasible for decentralized deployment. With these costs for CO 2 and by extracting and selling high-value PC ($\$$50/kg) and mid-value protein supplement ($\$$6/kg), the remaining biomass can be hydrothermally treated into biofuel for $\$$2.50/gallon, and would support a small first-of-a-kind biorefinery capable of producing 500 barrels per day of biofuel. The project offers meaningful public benefits by advancing carbon removal technologies that are low-energy, modular, and adaptable to non-arable land and brackish water use. It aligns with national goals to develop advanced biotechnology and supports future pathways for bio-based fuels and products. By enabling direct coupling of CO 2 transfer into aqueous medium and biological carbon utilization, AUDACity lays the groundwork for effective algae cultivation without wasteful CO 2 delivery and is a promising and innovative solution for low-carbon fuel and bioproduct generation contributing to a vigorous bioeconomy.

09 BIOMASS FUELS↗

Visolis Microbial Chemical Intermediate Library Screening (CRADA Final Report)

Visolis is developing a commercial process for the bioproduction of a chemical intermediate, towards the derivative production of a portfolio of bio-based chemicals with large application potential, from drop-in commodity chemicals, to innovative specialty chemical offerings, to materials for multiple end markets and industries, which will ultimately benefit consumers and the public. Visolis already has several variants of a microbe that produce the chemical intermediate at distinct levels (i.e. high, medium, and low). They are currently pursuing transcriptomics analysis for some of these strains, towards a better understanding of the biology behind what makes certain strains perform better than others. There exist genome-scale library approaches for the microbe that could be used to screen gene disruption, overexpression, or repression candidates for perturbations to the production of the chemical intermediate. These approaches often reveal opportunities for further production improvement that are not otherwise accessible using hypothesis-driven metabolic engineering approaches. However, Visolis, while it could generate or procure such genome-scale libraries, does not have the automated strain engineering workflows required to screen thousands of variants, obtaining a production phenotype and a genotype for each. The purpose of this collaboration is to use LBNL and SNL capabilities to enable Visolis to effectively screen thousands of genome-scale library strain variants for phenotype/genotype relationships that will complement Visolis’ transcriptomic investigations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Technical and Economic Assessment and Gap Analysis of Advanced Nuclear Reactor Integration with a Reference Methanol Synthesis Plant

Efforts continue to identify the most-economic methods to decarbonize several sectors of the United States (U.S.) economy. Industrial processes such as synfuel synthesis and high value commodity chemicals rely heavily on energy-dense and easily stored and transported fossil fuels, which power and feed their operations. Steam methane reforming (SMR) is a widely used process for producing methanol. In this process, methane (CH 4 ) from natural gas (NG) reacts with steam (H 2 O) over a catalyst at high temperatures (700°1,000°C) to produce syngas, a mixture of hydrogen (H 2 ) and carbon monoxide (CO). The syngas is then converted into methanol (CH 3 OH) through a second catalytic reaction. This method is known for being an efficient and commonly employed pathway for industrial methanol production. The high-temperature heat needed for SMR, which is currently used in the natural-gas-to-methanol process, cannot be supplied by small modular nuclear reactor (SMNR) direct heating; the temperatures required for the SMR process exceed those of the main steam produced by near-market high-temperature gas reactors (HTGRs). For the conventional methanol process, this leaves possible nuclear-integration opportunities that include: (1) blending nuclear hydrogen into the SMR NG fuel, or (2) assessing alternative synthesis routes leveraging nuclear capabilities and steam electrolysis outputs. In the reference methanol plant, SMR provides the methanol-synthesis reactor with H 2 and co. In Case (2), the state-of-the-art reverse water gas shift (RWGS) pathway achieves the same, sourcing carbon from an industrial CO 2 source.

08 - HYDROGEN↗

Precursor Analysis Report: Doppelpaymer Ransomware Attack on Petroleos Mexicanos (PEMEX) 2019

The DoppelPaymer Ransomware Attack on Petroleos Mexicanos (PEMEX) 2019 Precursor Analysis Report leverages publicly available information about the PEMEX cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. The 2019 DoppelPaymer ransomware attack on PEMEX, Mexico’s nationalized petroleum corporation, highlights a unique threat that ransomware and cybercriminal extortion poses to Operational Technology (OT) environments in critical infrastructure. The incident began with an employee downloading commodity malware that allowed adversaries to gain initial access to PEMEX’s enterprise environment. After conducting privilege escalation, tool ingress, and data exfiltration, the adversaries deployed DoppelPaymer ransomware throughout the PEMEX enterprise environment, resulting in the company having to take dozens of systems offline for at least several days. Although PEMEX stated that their operations were not affected, the data exfiltrated from PEMEX was made available for download on DoppelPaymer’s leak site, as well as on other illicit criminal forums. This stolen data included not only company information, but also sensitive OT-specific configuration data. This incident showcases how cybercriminal exfiltration and posting of sensitive OT architecture documentation can pose security concerns for the targeted organization for years due to the long lifespan of OT assets and architectures. Researchers and analysts identified 18 unique techniques utilized during the attack with a total of 190 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Fifteen of the identified techniques used during the DoppelPaymer ransomware attack were precursors to the triggering event. Analysis identified 163 observables associated with these precursor techniques, 34 of which were assessed to have an increased likelihood of being perceived in the 60 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Hydrocracking Plastic Mixtures into Xylene

Our research aims to tackle the challenge in recycling end-of-life plastics, the accumulation of which has become a grand challenge to our society, sustainability and economy. Guided by life-cycle assessment (LCA) and tech-economic analysis (TEA), we specifically target the catalytic conversion of low-cost #3-7 plastic mixtures ($\$$5/ton) into p-xylene (>$\$$1000/ton), one of the most valuable hydrocarbon products. This goal is achieved by carrying out integrated research including catalysis, process engineering, and reactor design. The ultimate goal of this project is to enable energy-efficient and economically viable depolymerization of end-of-life plastic mixtures into value-added commodity chemicals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advanced Microturbine Systems

In July 2000, the United Technologies Research Center (UTRC) was one of five recipients of a US Department of Energy contract under the Advanced Microturbine System (AMS) program managed by the Office of Distributed Energy (DE). The AMS program resulted from several government-industry workshops that recognized that microturbine systems could play an important role in improving customer choice and value for electrical power. That is, the group believed that electrical power could be delivered to customers more efficiently and reliably than the grid if an effective distributed energy strategy was followed. Further, the production of this distributed power would be accomplished with less undesirable pollutants of nitric oxides (NOx) unburned hydrocarbons (UHC), and carbon monoxide (CO). In 2000, the electrical grid delivered energy to US customers at a national average of approximately 32% efficiency. This value reflects a wide range of powerplants, but is dominated by older, coal burning stations that provide approximately 50% of US electrical power. The grid efficiency is also affected by transmission and distribution (T&D) line losses that can be significant during peak power usage. In some locations this loss is estimated to be 15%. Load pockets can also be so constrained that sufficient power cannot be transmitted without requiring the installation of new wires. New T&D can be very expensive and challenging as it is often required in populated regions that do not want above ground wires. While historically grid reliability has satisfied most customers, increasing electronic transactions and the computer-controlled processes of the 'digital economy' demand higher reliability. For them, power outages can be very costly because of transaction, work-in-progress, or perishable commodity losses. Powerplants that produce the grid electrical power emit significant levels of undesirable NOx, UHC, and CO pollutants. The level of emission is quoted as either a technology metric or a system-output metric. A common form for the technology metric is in the units of PPM {at} 15% O2. In this case the metric reflects the molar fraction of the pollutant in the powerplant exhaust when corrected to a standard exhaust condition as containing 15% (molar) oxygen, assuring that the PPM concentrations are not altered by subsequent air addition or dilution. Since fuel combustion consumes oxygen, the output oxygen reference is equivalent to a fuel input reference. Hence, this technology metric reflects the moles of pollutant per mole of fuel input, but not the useful output of the powerplant-i.e. the power. The system-output metric does embrace the useful output and is often termed an output-based metric. A common form for the output-based metric is in the units of lb/MWh. This is a system metric relating the pounds of pollutant to output energy (e.g., MWh) of the powerplant.

01 COAL, LIGNITE, AND PEAT↗

April 2008 monitoring report for Morrill, Kansas.

In September 2005, the Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) initiated periodic sampling of groundwater in the vicinity of a grain storage facility formerly operated by the CCC/USDA at Morrill, Kansas. The sampling at Morrill is being performed on behalf of the CCC/USDA by Argonne National Laboratory, in accord with a monitoring program approved by the Kansas Department of Health and Environment (KDHE), to monitor levels of carbon tetrachloride contamination identified in the groundwater at this site (Argonne 2004, 2005a). This report provides results for the most recent monitoring event, in April 2008. Under the KDHE-approved monitoring plan (Argonne 2005b), groundwater was initially sampled twice yearly for a recommended period of two years (in fall 2005, in spring and fall 2006, and in spring and fall 2007). The samples were analyzed for volatile organic compounds (VOCs), as well as for selected geochemical parameters to aid in the evaluation of possible natural contaminant degradation (reductive dechlorination) processes in the subsurface environment. During the recommended two-year period, the originally approved scope of the monitoring was expanded to include vegetation sampling (initiated in October 2006) and surface water and stream bed sediment sampling (initiated in March 2007, after a visual reconnaissance along Terrapin Creek [Argonne 2007a]). The analytical results for groundwater sampling events at Morrill in September 2005, March 2006, September 2006, March 2007, and October 2007 were documented previously (Argonne 2006a,b, 2007b, 2008). Those results consistently demonstrated the presence of carbon tetrachloride contamination, at levels exceeding the KDHE Tier 2 risk-based screening level (5.0 {micro}g/L) for this compound, in a groundwater plume extending generally south-southeastward from the former CCC/USDA facility, toward Terrapin Creek at the south edge of the town. The results of those five monitoring events gave little indication of consistent changes in the contaminant concentrations at the individual monitoring points or of plume migration. Low levels (= 1.3 {micro}g/L) of carbon tetrachloride were persistently detected at monitoring well MW8S, however, on the bank of an intermittent tributary to Terrapin Creek. This observation suggested a possible risk of contamination of the surface waters of the creek. That concern became the driving force for ongoing monitoring and consideration of possible remedial options for Morrill. In light of the early findings, in 2006 the CCC/USDA recommended expansion of the approved monitoring program to include the collection and analysis of surface water samples along Terrapin Creek (Argonne 2006a). At the request of the KDHE (2007a), locations for both surface water and shallow sediment sampling were discussed with the KDHE in January 2007. An addendum to the existing monitoring plan and a standard operating procedure (SOP AGEM-15) for sediment sampling were submitted to the KDHE on the basis of these discussions (Argonne 2007c,d). To supplement the original scope of the monitoring, Argonne also sampled natural vegetation along Terrapin Creek in October 2006, April 2007, and July 2007 for analyses for VOCs. The results of the plant tissue analyses were reported previously (Argonne 2008). The April 2008 sampling event reported here represents a continuation of the two-year monitoring program, as requested by the KDHE (2007b). The sampling is presently conducted, in accord with the monitoring plan (Argonne 2005b) and the addendum to that plan (Argonne 2007a), in a network of 12 monitoring wells and 3 private wells (Figure 1.1), at locations approved by the KDHE. An event that affects the results of the April 2008 monitoring is the installation of an irrigation well, owned by Kent Grimm, on the south side of Terrapin Creek, near monitoring well MW6S. The WWC-5 well registration form (in Appendix A) indicates that the well diameter is 16 in., that artesian flow is occurring at a rate of 250 gpm, and that installation occurred on March 10, 2008.

54 ENVIRONMENTAL SCIENCES↗

July 2008 monitoring results for Barnes, Kansas.

The Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) operated a grain storage facility at Barnes, Kansas, during most of the interval 1949-1974. Carbon tetrachloride contamination was initially detected in 1986 in the town's public water supply wells. In 2006-2007, the CCC/USDA conducted a comprehensive targeted investigation at and near its former property in Barnes to characterize this contamination. Those results were reported previously (Argonne 2008a). In November 2007, the CCC/USDA began quarterly groundwater monitoring at Barnes. The monitoring is being conducted on behalf of the CCC/USDA by Argonne National Laboratory, in accord with the recommendations made in the report for the 2006-2007 targeted investigation (Argonne 2008a). The objective is to monitor the carbon tetrachloride contamination identified in the groundwater at Barnes. The sampling is presently conducted in a network of 28 individual monitoring wells (at 19 distinct locations), 2 public water supply wells, and 1 private well (Figure 1.1). The results of the 2006-2007 targeted investigation and the subsequent monitoring events in November 2007 (Argonne 2008b) and March 2008 (Argonne 2008c) demonstrated the presence of carbon tetrachloride contamination in groundwater at levels slightly exceeding the Kansas Department of Health and Environment (KDHE) Tier 2 risk-based screening level (RBSL) of 5.0 {micro}g/L for this compound. The contaminant plume appears to extend from the former CCC/USDA property northwestward, toward the Barnes public water supply wells. Information obtained during the 2006-2007 investigations indicates that at least one other potential source might have contributed to the groundwater contaminant plume (Argonne 2008a). This current report presents the results of the third monitoring event, conducted in July 2008. During this third monitoring event, low-flow sampling methods were used to purge and sample all wells. This was the second event at Barnes during which low-flow sampling methods were used.

54 ENVIRONMENTAL SCIENCES↗

Final work plan : investigation of potential contamination at the former CCC/USDA grain storage facility in Hanover, Kansas.

The Commodity Credit Corporation (CCC), an agency of the U.S. Department of Agriculture (USDA), operated a grain storage facility at the northeastern edge of the city of Hanover, Kansas, from 1950 until the early 1970s. During this time, commercial grain fumigants containing carbon tetrachloride were in common use by the grain storage industry to preserve grain in their facilities. In February 1998, trace to low levels of carbon tetrachloride (below the maximum contaminant level [MCL] of 5.0 {micro}g/L) were detected in two private wells near the former grain storage facility at Hanover, as part of a statewide USDA private well sampling program that was implemented by the Kansas Department of Health and Environment (KDHE) near former CCC/USDA facilities. In April 2007, the CCC/USDA collected near-surface soil samples at 1.8-2 ft BGL (below ground level) at 61 locations across the former CCC/USDA facility. All soil samples were analyzed by the rigorous gas chromatograph-mass spectrometer analytical method (purge-and-trap method). No contamination was found in soil samples above the reporting limit of 10 {micro}g/kg. In July 2007, the CCC/USDA sampled indoor air at nine residences on or adjacent to its former facility to address the residents concerns regarding vapor intrusion. Low levels of carbon tetrachloride were detected at four of the nine homes. Because carbon tetrachloride found in private wells and indoor air at the site might be linked to historical use of fumigants containing carbon tetrachloride at its former grain storage facility, the CCC/USDA is proposing to conduct an investigation to determine the source and extent of the carbon tetrachloride contamination associated with the former facility. This investigation will be conducted in accordance with the intergovernmental agreement between the KDHE and the Farm Service Agency (FSA) of the USDA. The investigation at Hanover will be performed, on behalf of the CCC/USDA, by the Environmental Science Division of Argonne National Laboratory. Argonne is a nonprofit, multidisciplinary research center operated by UChicago Argonne, LLC, for the U.S. Department of Energy (DOE). The CCC/USDA has entered into an interagency agreement with DOE, under which Argonne provides technical assistance to the CCC/USDA with environmental site characterization and remediation at its former grain storage facilities. Seven technical objectives have been proposed for the Hanover investigation. They are as follows: (1) Identify the sources and extent of soil contamination beneath the former CCC/USDA facility; (2) Characterize groundwater contamination beneath the former CCC/USDA facility; (3) Determine groundwater flow patterns; (4) Define the vertical and lateral extent of the groundwater plume outside the former CCC/USDA facility; (5) Evaluate the aquifer and monitor the groundwater system; (6) Identify any other potential sources of contamination that are not related to activities of the CCC/USDA; and (7) Determine whether there is a vapor intrusion problem at the site attributable to the former CCC/USDA facility. The technical objectives will be accomplished in a phased approached. Data collected during each phase will be evaluated to determine whether the subsequent phase is necessary. The KDHE project manager and the CCC/USDA will be contacted during each phase and kept apprised of the results. Whether implementation of each phase of work is necessary will be discussed and mutually agreed upon by the CCC/USDA and KDHE project managers.

54 ENVIRONMENTAL SCIENCES↗

March 2008 monitoring results for Centralia, Kansas.

In September 2005, periodic sampling of groundwater was initiated by the Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) in the vicinity of a grain storage facility formerly operated by the CCC/USDA at Centralia, Kansas. The sampling at Centralia is being performed on behalf of the CCC/USDA by Argonne National Laboratory, in accord with a monitoring program approved by the Kansas Department of Health and Environment (KDHE). The objective is to monitor levels of carbon tetrachloride contamination identified in the groundwater at Centralia (Argonne 2003, 2004, 2005a). Under the KDHE-approved monitoring plan (Argonne 2005b), the groundwater is being sampled twice yearly (for a recommended period of two years) for analyses for volatile organic compounds (VOCs), as well as measurement of selected geochemical parameters to aid in the evaluation of possible natural contaminant degradation (reductive dechlorination) processes in the subsurface environment. The sampling is presently conducted in a network of 10 monitoring wells and 6 piezometers (Figure 1.1), at locations approved by the KDHE (Argonne 2006a). The results of groundwater sampling and VOCs analyses in September-October 2005, March 2006, September 2006, March 2007, and September 2007 were documented previously (Argonne 2006a,b, 2007a, 2008). The results have demonstrated the presence of carbon tetrachloride contamination, at levels exceeding the KDHE Tier 2 Risk-Based Screening Level of 5 {micro}g/L for this compound, in a broad groundwater plume that has shown little movement. This report presents the results of the groundwater sampling at Centralia in March 2008, performed in accord with the KDHE-approved monitoring plan (Argonne 2005b). The September 2007 sampling represented the fifth and final monitoring event performed under the recommended two-year monitoring program approved by the KDHE. The March 2008 sampling begins an extension of the approved monitoring that is to continue until the final site remedy has been implemented and a comprehensive program of performance and compliance monitoring has been established at Centralia (KDHE 2008a).

54 ENVIRONMENTAL SCIENCES↗

Results of groundwater monitoring at Everest, Kansas, in April 2008.

On September 7, 2005, the Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) presented a Scoping Memo (Argonne 2005) for preliminary consideration by the Kansas Department of Health and Environment (KDHE), suggesting possible remedial options for the carbon tetrachloride contamination in groundwater at Everest, Kansas. The suggested approaches were discussed by representatives of the KDHE, the CCC/USDA, and Argonne at the KDHE office in Topeka on September 8-9, 2005, along with other technical and logistic issues related to the Everest site. In response to these discussions, the KDHE recommended (KDHE 2005) evaluation of several remedial processes, either alone or in combination, as part of a Corrective Action Study (CAS) for Everest. The primary remedial processes suggested by the KDHE were the following: Hydraulic control by groundwater extraction with aboveground treatment; Air sparging (AS) coupled with soil vapor extraction (SVE) in large-diameter boreholes (LDBs); and Phytoremediation. As a further outcome of the 2005 meeting and as a precursor to development of a possible CAS, the CCC/USDA completed the following supplemental investigations at Everest to address several specific technical concerns discussed with the KDHE: (1) Construction of interpretive cross sections at strategic locations selected by the KDHE along the main plume migration pathway, to depict the hydrogeologic characteristics affecting groundwater flow and contaminant movement (Argonne 2006a). (2) A field investigation in early 2006 (Argonne 2006b), as follows: (a) Installation and testing of a production well and associated observation points, at locations approved by the KDHE, to determine the response of the Everest aquifer to groundwater extraction near the Nigh property. (b) Groundwater sampling for the analysis of volatile organic compounds (VOCs) and the installation of additional permanent monitoring points at locations selected by the KDHE, to further constrain the existing contaminant plume. (c) Resampling of all existing permanent monitoring points for VOCs and biodegradation parameter analyses, at the request of the KDHE. On the basis of these studies (Argonne 2006a,b) and the CCC/USDA's past investigations at Everest (Argonne 2006c), the CCC/USDA concluded that groundwater extraction is not an effective remedial option for the main body of the groundwater plume, and the KDHE concurred (KDHE 2006); the KDHE later noted, however (KDHE 2007a), that this and other technologies might represent viable remedial options in the event of further downgradient migration of the plume toward the intermittent creek. In February 2007, the CCC/USDA presented preliminary analyses of (1) the AS-SVE remedial alternative, incorporating the use of LDBs, and (2) the risks to human health and the environment posed by the observed carbon tetrachloride plume in groundwater (Argonne 2007a). The results of these analyses demonstrated the following: (1) Neither groundwater extraction nor AS-SVE in LDBs represents a practical approach for effective remediation of the groundwater contamination at Everest (near the Nigh property). (2) Periodic sampling and analyses for VOCs conducted by the CCC/USDA documented that the areal extent and range of carbon tetrachloride concentrations detected in the groundwater plume at Everest had changed relatively little from 2000 to 2006. (3) Estimates of groundwater flow and contaminant migration times, based on the hydrogeologic properties of the groundwater flow system identified at Everest (Argonne 2003, 2006b,c), indicated that, at minimum, approximately 4 years would be required for the carbon tetrachloride plume (in the subsurface) to reach the vicinity of the intermittent creek directly west of the Nigh property, and more than 20 years would be required for the contamination to reach the identified groundwater discharge area southwest of the Nigh property. (4) The existing (January-March 2006) plume posed no immediate danger of contamination to the surface waters of the intermittent creek. In light of these observations, the CCC/USDA proposed a phased program--over approximately 2-3 years--of groundwater sampling, surface water sampling, and related monitoring activities at Everest to (1) identify locations where a phytoremediation system would be effective and determine that area's extent and (2) support the potential development of a phytoremediation treatment alternative for the site. The recommended elements of the monitoring program are summarized in Table 1.1. In conjunction with this program, both the CCC/USDA and the KDHE recommended the construction of several new monitoring wells, at locations along and near the intermittent creek west of the Nigh property (Argonne 2007b; KDHE 2007b).

54 ENVIRONMENTAL SCIENCES↗

Final work plan : supplemental upward vapor intrusion investigation at the former CCC/USDA grain storage facility in Hanover, Kansas.

The Commodity Credit Corporation (CCC), an agency of the U.S. Department of Agriculture (USDA), operated a grain storage facility at the northeastern edge of the city of Hanover, Kansas, from 1950 until the early 1970s. During this time, commercial grain fumigants containing carbon tetrachloride were in common use by the grain storage industry to preserve grain in their facilities. In February 1998, trace to low levels of carbon tetrachloride (below the maximum contaminant level [MCL] of 5.0 {micro}g/L) were detected in two private wells near the former grain storage facility at Hanover, as part of a statewide USDA private well sampling program that was implemented by the Kansas Department of Health and Environment (KDHE) near former CCC/USDA facilities. In 2007, the CCC/USDA conducted near-surface soil sampling at 61 locations and also sampled indoor air at nine residences on or adjacent to its former Hanover facility to address the residents concerns regarding vapor intrusion. Low levels of carbon tetrachloride were detected at four of the nine homes. The results were submitted to the KDHE in October 2007 (Argonne 2007). On the basis of the results, the KDHE requested sub-slab sampling and/or indoor air sampling (KDHE 2007). This Work Plan describes, in detail, the proposed additional scope of work requested by the KDHE and has been developed as a supplement to the comprehensive site investigation work plan that is pending (Argonne 2008). Indoor air samples collected previously from four homes at Hanover were shown to contain the carbon tetrachloride at low concentrations (Table 2.1). It cannot be concluded from these previous data that the source of the detected carbon tetrachloride is vapor intrusion attributable to former grain storage operations of the CCC/USDA at Hanover. The technical objective of the vapor intrusion investigation described here is to assess the risk to human health due to the potential for upward migration of carbon tetrachloride and chloroform into four homes located on or adjacent to the former CCC/USDA facility. The technical objective will be accomplished by collecting sub-slab vapor samples. The preliminary data collected during the July 2007 investigation did not fully address the source of or migration pathway for the carbon tetrachloride detected in the four homes. The scope of work proposed here will generate additional data needed to help evaluate whether the source of the detected carbon tetrachloride is vapor intrusion attributable to activities of the CCC/USDA. The additional vapor sampling at Hanover will be performed, on behalf of the CCC/USDA, by the Environmental Science Division of Argonne National Laboratory and H&P Mobile Geochemistry of San Diego (http://www.handpmg.com). Argonne is a nonprofit, multidisciplinary research center operated by UChicago Argonne, LLC, for the U.S. Department of Energy (DOE). The CCC/USDA has entered into an interagency agreement with DOE, under which Argonne provides technical assistance to the CCC/USDA with environmental site characterization and remediation at its former grain storage facilities. The professional staff members of H&P Mobile Geochemistry are nationally leading experts in soil gas sampling and vapor intrusion investigations.

54 ENVIRONMENTAL SCIENCES↗