Search NASA⌕ Search

SEARCH · Search NASA

Results for “condition based monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Direct Radiative Effect of Aerosols Based on PARASOL and OMI Satellite Observations

Accurate portrayal of the aerosol characteristics is crucial to determine aerosol contribution to the Earth's radiation budget. We employ novel satellite retrievals to make a new measurement-based estimate of the shortwave direct radiative effect of aerosols (DREA), both over land and ocean. Global satellite measurements of aerosol optical depth, single-scattering albedo (SSA), and phase function from PARASOL (Polarization and Anisotropy of Reflectances for Atmospheric Sciences coupled with Observations from a Lidar) are used in synergy with OMI (Ozone Monitoring Instrument) SSA. Aerosol information is combined with land-surface bidirectional reflectance distribution function and cloud characteristics from MODIS (Moderate Resolution Imaging Spectroradiometer) satellite products. Eventual gaps in observations are filled with the state-of-the-art global aerosol model ECHAM5-HAM2. It is found that our estimate of DREA is largely insensitive to model choice. Radiative transfer calculations show that DREA at top-of-atmosphere is −4.6 +/- 1.5 W/sq m for cloud-free and −2.1 +/- 0.7 W/sq m for all-sky conditions, during year 2006. These fluxes are consistent with, albeit generally less negative over ocean than, former assessments. Unlike previous studies, our estimate is constrained by retrievals of global coverage SSA, which may justify different DREA values. Remarkable consistency is found in comparison with DREA based on CERES (Clouds and the Earth's Radiant Energy System) and MODIS observations.

Globalsatellite measurements↗

Ionic-Based Electrochemical Gas Sensors for Low-Cost, High-Sensitivity SO2 Detection

Sulfur dioxide (SO2) is a toxic gas associated with adverse health and environmental effects that necessitate reliable monitoring techniques. Here, we report the development of an all-solid-state electrochemical sensor utilizing a lithium borate (Li3BO3) solid electrolyte capable of subppm of SO2 detection. While subppm of SO2 sensing has been previously demonstrated in other solid-state electrolyte systems─such as stabilized zirconia, natrium super ionic conductors (NASICON) under mixed-potential conditions─here we establish Li3BO3 as an alternative solid electrolyte enabling equilibrium potentiometric sensing in an all-solid architecture. This sensor demonstrates a detection limit of at least 0.25 ppm, surpassing the human-olfactory threshold and meeting the rigorous requirements for industrial and personal monitoring applications. The sensing mechanism relies on the formation of Li2SO4 on the electrode surface, as evidenced by multimodal characterization techniques, including Raman spectroscopy, scanning electron microscopy (SEM), and scanning transmission electron microscopy (STEM). The strong linear correlation between the open-circuit potential (OCV) and the logarithm of SO2 concentration between 0.25 and 2 ppm indicates that the response is Nernstian in nature.

Lagunas, Francisco (ORCID:000000026377683X)↗

Monitoring the defoliation of hardwood forests in Pennsylvania using LANDSAT

An automated system for conducting annual gypsy moth defoliation surveys using LANDSAT MSS data and digital processing techniques is described. A two-step preprocessing procedure was developed that uses multitemporal data sets representing forest canopy conditions before and after defoliation to create a digital image in which all nonforest cover types are eliminated or masked out of a LANDSAT image that exhibits insect defoliation. A temporal window for defoliation assessment was identified and a statewide data base was established. A data management system to interface image analysis software with the statewide data base was developed and a cost benefit analysis of this operational system was conducted.

Dottavio, C. L.↗

An Advanced Approach to Simultaneous Monitoring of Multiple Bacteria in Space

The utility of a novel microarray-based microbial analyzer was demonstrated by the rapid detection, imaging, and identification of a mixture of microorganisms found in a waste water sample from the Lunar-Mars Life Support Test Project through the synergistic combination of: (1) judicious RNA probe selection via algorithms developed by University of Houston scientists; (2) tuned surface chemistries developed by Baylor College of Medicine scientists to facilitate hybridization of rRNA targets to DNA probes under very low salt conditions, thereby minimizing secondary structure; and (3) integration of the microarray printing and detection/imaging instrumentation by Genometrix to complete the quantitative analysis of microorganism mixtures.

Eggers, M.↗

Real-Time and Online Monitoring of Glucose Contents by Using Molecular Imprinted Polymer-Based IDEs Sensor

A highly sensitive, selective, reversible, and reusable glucose sensor is developed by using molecularly imprinted polymer-based artificial receptors onto interdigital transducer. Sensor receptors were synthesized through bulk imprinting technology by using styrene as monomer, ethylene glycol dimethacrylate (EGDMA) as cross-linker, and AIBN as free radical initiator. Topography of the synthesized receptors was investigated by scanning electron microscopy (SEM). Fabricated sensor showed concentration-dependent linear and reversible response with lower limit of detection of 30 ppb and upper limit of detection ~ 500 ppm. Furthermore, newly fabricated sensor is highly selective towards its analyte of interest in the presence of other competing agents, and the regeneration of sensor response has been assessed with the percentage error of less than 2% under the period of 1 year at room temperature and pressure conditions. The reported sensor may have potential technological applications in the field of medical diagnostics, food, and pharmaceutical industry.

60 APPLIED LIFE SCIENCES↗

Biochemical properties of glycerol kinase from the hypersaline-adapted archaeon Haloferax volcanii

ABSTRACT Extremophilic microorganisms are promising candidates for industrial and analytical biocatalysis.Haloferax volcanii, a halophilic archaeon that prefers glycerol over glucose, channels this substrate into central metabolism through glycerol kinase (GK). Here, we report the biochemical properties ofH. volcaniiGK and its potential for biotechnological applications. An N-terminal His-tagged GK was functionalin vivoand yielded 3 mg/L culture—4.5 times more enzyme than a C-terminal StrepII-tagged version. Size exclusion chromatography revealed a glycerol-induced oligomeric shift from homodimer to a dimer-dominant state with detectable tetramer. The purified enzyme showed robust activity across broad pH and salinity ranges, with optimal activity at 100 mM NaCl and 50°C–60°C. It retained catalytic activity in 5%–10% dimethyl sulfoxide (DMSO) and crude glycerol containing methanol. His-GK was freeze-thaw stable and thermotolerant in 2 M NaCl buffers. In the absence of ligands, the enzyme’s melting temperature (T m ) was 80°C. Glycerol increased the T m to 85°C, and combinations with MgCl₂ (84°C) or ATP (88°C) provided further stabilization. The highest T m (89°C) occurred with all three ligands, suggesting a cumulative stabilizing effect. Kinetic analyses revealed positive cooperativity for glycerol, ATP, and Mg² + ; Mn² + and Co² + also supported the activity.H. volcaniiGK is the first known GK to exhibit positive cooperativity with glycerol and ATP. Its high stability and substrate flexibility support its use in biodiesel waste valorization,in vitrobiocatalysis, and biosensor development—applications demanding robust, specific, and stable enzymes. IMPORTANCE This study reveals thatH. volcaniiGK exhibits positive cooperativity for glycerol, ATP, and Mg² + , a kinetic feature not previously reported for glycerol kinases. This behavior enables steep, switch-like responses to small substrate changes, offering unique advantages for biosensor design. Importantly,H. volcaniiGK also maintains high activity under extreme salinity, temperature, broad pH, and solvent conditions that typically limit enzyme use in industrial and environmental applications. These traits make this GK an ideal candidate for enzyme-based biosensors, which often suffer from poor tolerance to pH, solvent, and thermal stress. Its robustness supports its use in cross-linked enzyme crystals, an immobilization method that enhances enzyme stability and reusability under harsh conditions. Moreover, GKs are already employed in Mg² + detection kits; however,H. volcaniiGK’s ability to tolerate and respond to diverse divalent cations (e.g., Co² + , Mn² + ) broadens their potential for pollutant detection and environmental monitoring. These features collectively positionH. volcaniiGK as a valuable biocatalyst for biosensing,in vitrodiagnostics, and biotechnological applications requiring both precision and durability.

Biotechnology & Applied Microbiology↗

Inverter ratio failure detector

A failure detector which detects the failure of a dc to ac inverter is disclosed. The inverter under failureless conditions is characterized by a known linear relationship of its input and output voltages and by a known linear relationship of its input and output currents. The detector includes circuitry which is responsive to the detector's input and output voltages and which provides a failure-indicating signal only when the monitored output voltage is less by a selected factor, than the expected output voltage for the monitored input voltage, based on the known voltages' relationship. Similarly, the detector includes circuitry which is responsive to the input and output currents and provides a failure-indicating signal only when the input current exceeds by a selected factor the expected input current for the monitored output current based on the known currents' relationship.

Wagner, A. P.↗

Design and performance of the KSC Biomass Production Chamber

NASA's Controlled Ecological Life Support System program has instituted the Kennedy Space Center 'breadboard' project of which the Biomass Production Chamber (BPC) presently discussed is a part. The BPC is based on a modified hypobaric test vessel; its design parameters and operational parameters have been chosen in order to meet a wide range of plant-growing objectives aboard future spacecraft on long-duration missions. A control and data acquisition subsystem is used to maintain a common link between the heating, ventilation, and air conditioning system, the illumination system, the gas-circulation system, and the nutrient delivery and monitoring subsystems.

Prince, Ralph P.↗

The characterization of an air pollution episode using satellite total ozone measurements

A case study is presented which demonstrates that measurements of total ozone from a space-based platform can be used to study a widespread air pollution episode over the southeastern U.S. In particular, the synoptic-scale distribution of surface-level ozone obtained from an independent analysis of ground-based monitoring stations appears to be captured by the synoptic-scale distribution of total ozone, even though about 90 percent of the total ozone is in the stratosphere. Additional analyses of upper air meteorological data, other satellite imagery, and in situ aircraft measurements of ozone likewise support the fact that synoptic-scale variability of tropospheric ozone is primarily responsible for the observed variability in total ozone under certain conditions. The use of the type of analysis discussed in this study may provide an important technique for understanding the global budget of tropospheric ozone.

Fishman, Jack↗

Lessons Learned During Implementation and Early Operations of the DS1 Beacon Monitor Experiment

A new approach to mission operations will be flight validated on NASA's New Millennium Program Deep Space One (DS1) mission which launched in October 1998. The Beacon Monitor Operations Technology is aimed at decreasing the total volume of downlinked engineering telemetry by reducing the frequency of downlink and the volume of data received per pass. Cost savings are achieved by reducing the amount of routine telemetry processing and analysis performed by ground staff. The technology is required for upcoming NASA missions to Pluto, Europa, and possibly some other missions. With beacon monitoring, the spacecraft will assess its own health and will transmit one of four beacon messages each representing a unique frequency tone to inform the ground how urgent it is to track the spacecraft for telemetry. If all conditions are nominal, the tone provides periodic assurance to ground personnel that the mission is proceeding as planned without having to receive and analyze downlinked telemetry. If there is a problem, the tone will indicate that tracking is required and the resulting telemetry will contain a concise summary of what has occurred since the last telemetry pass. The primary components of the technology are a tone monitoring technology, AI-based software for onboard engineering data summarization, and a ground response system. In addition, there is a ground visualization system for telemetry summaries. This paper includes a description of the Beacon monitor concept, the trade-offs with adapting that concept as a technology experiment, the current state of the resulting implementation on DS1, and our lessons learned during the initial checkout phase of the mission. Applicability to future missions is also included.

Sherwood, Rob↗

Evaluating the success of treatments that slow spread of an invasive insect pest

BACKGROUND Treatments for the suppression and eradication of insect populations undergo substantial testing to ascertain their efficacy and safety, but the generally limited spatial and temporal scope of such studies limit knowledge of how contextual factors encountered in operational contexts shape the relative success of pest management treatments. These contextual factors potentially include ecological characteristics of the treated area, or the timing of treatments relative to pest phenology and weather events. We used an extensive database on over 1000 treatments of nascent populations of Lymantria dispar (L.) (gypsy moth) to examine how place-based and time-varying conditions shape the success of management treatments. RESULTS We found treatment success to vary across states and years, and to be highest in small treatment blocks that are isolated from other populations. In addition, treatment success tended to be lower in treatment blocks with open forest canopies, possibly owing to challenges of effectively distributing treatments in these areas. CONCLUSIONS Our findings emphasize the importance of monitoring for early detection of nascent gypsy moth colonies in order to successfully slow the spread of the invasion. Additionally, operations research should address best practices for effectively treating with patchy and open forest canopies. © 2021 Society of Chemical Industry.

Jonathan A Walter↗

An Optical Oxygen Sensor for Long-Term Continuous Monitoring of Dissolved Oxygen in Perfused Bioreactors

For long-term growth of man1ITlalian cells in perfused bioreactors, it is essential to monitor the concentration of dissolved oxygen (DO) present in the culture medium to quantitate and control level of DO. Continuous measurement of the amount of DO in the cell culture medium in-line under sterile conditions in NASA's perfused bioreactor requires that the oxygen sensor provide increased sensitivity and be sterilizable and nontoxic. Additionally, long-term cell culture experiments require that the calibration be maintained several weeks or months. Although there are a number of sensors for dissolved oxygen on the market and under development elsewhere, very few meet these stringent conditions. An optical oxygen sensor (BOXY) based on dynamic fluorescent quenching and a pulsed blue LED light source was developed in our laboratory to address these requirements. Tris( 4,7 -diphenyl-l, 1 O-phenanthroline )ruthenium(II) chloride is employed as the fluorescent dye indicator. The sensing element consists of a glass capillary (OD 4.0 mm; ID 2.0 mm) coated internally with a thin layer of the fluorescent dye in silicone matrix and overlayed with a black shielding layer. Irradiation of the sensing element with blue light (blue LED with emission maximum at 475 nm) generates a red fluorescence centered at 626 nm. The fluorescence intensity is correlated to the concentration of DO present in the culture medium, following the modified non-linear Stern-Volmer equation. By using a pulsed irradiating light source, the problem of dye-bleaching, which is often encountered in long-term continuous measurements of tIns type, 'is minimized. To date we achieved sensor resolution of 0.3 mmHg at 50 mmHg p02, and 0.6 mmHg at 100 mmHg p02, with a response time of about one minute. Calibration was accomplished in sterile phosphate-buffered saline with a blood-gas analyzer (BGA) measurement as reference. Stand-alone software was also developed to control the sensor and bioreactor as well as to acquire data. Two HOXY sensors with a single calibration were employed to continuously monitor the DO in GTSF-2 medium during a Baby Hamster Kidney (BHK-21) cell culture in a Rotating Wall Perfused Vessel (RWPV) bioreactor for 90 days. HOXY sensors were located at the inlet to and outlet from the bioreactor. One of the sensors was placed between an oxygenator and the inlet to the bioreactor. The dissolved oxygen concentrations determined by both sensors were compared with those measured regularly with the BGA reference. The cell culture was maintained for 110 days. Sensor output was found to correlate well with the BGA data throughout the experiment, where the DO of the medium ranged between 25 and 50 mmHg at the bioreactor outlet and 90-130 mmHg at the bioreactor inlet. Measuring DO with the HOXY sensors versus the BGA reference indicated bias values of -2 mmHg and -15 mmHg, and precision values of +/-3mmHg and +/-16 mmHg at the bioreactor inlet and outlet, respectively.

Gao, F. G.↗

Microprocessor-based cardiopulmonary monitoring system

The system uses a dedicated microprocessor for transducer control and data acquisition and analysis. No data will be stored in this system, but the data will be transmitted to the onboard data system. The data system will require approximately 12 inches of rack space and will consume only 100 watts of power. An experiment specific control panel, through a series of lighted buttons, will guide the operator through the test series providing a smaller margin of error. The experimental validity of the system was verified, and the reproducibility of data and reliability of the system checked. In addition, ease of training, ease of operator interaction, and crew acceptance were evaluated in actual flight conditions.

Source record↗

Ohio River Basin Water Resources: Monitoring Flash Drought Potential and Quantifying the Hydrologic Impacts in the Ohio River Basin

Flash drought conditions emerge in a matter of weeks following persistent weather anomalies, such as high temperatures or large vapor pressure deficits, that drive increased evaporative demand. Vegetation response rapidly depletes soil moisture, threatening surface water supplies, triggering significant crop loss, and increasing wildfire risk. Drought indices sensitive to flash drought are currently not included in drought forecast models in the Ohio River Basin (ORB). The team assessed and compared drought indices, gauge-based data, and satellite measurements over the course of the September 2019 flash drought event in the Ohio River Basin to investigate environmental fingerprints throughout flash drought evolution. Potential leading flash drought indicators were compared to the Standardized Precipitation Index (SPI) to aid the National Weather Service (NWS) Ohio River Forecast Center and Kentucky Climate Center in producing early warning flash drought forecasts. These drought indices included Evaporative Demand Drought Index (EDDI), Standardized Precipitation Evapotranspiration Index (SPEI), and Landscape Evaporative Response Index (LERI) (derived from Terra Moderate Resolution Imaging Spectroradiometer (MODIS)). Drought index behavior inherently varies based on parameters incorporated - EDDI measures evaporative demand through potential evapotranspiration, and demonstrates more variations due to sensitivity to seasonal changes in evaporative demand throughout the 2010-2019 study period. Conversely, LERI measures evaporative response through actual evapotranspiration, representing different environmental changes. Soil moisture response was evaluated using Soil Moisture Active Passive (SMAP) L-band radiometer data and Kentucky Mesonet gauge-based measurements. This analysis enables climatologists and weather forecasters to keep decision-makers and stakeholders better informed about drought risks, and to implement the appropriate actions for preparation of drought onset.

Adelaide Schmid↗

Airplane takeoff and landing performance monitoring system

The invention is a real-time takeoff and landing performance monitoring system which provides the pilot with graphic and metric information to assist in decisions related to achieving rotation speed (V sub R) within the safe zone of the runway or stopping the aircraft on the runway after landing or take off abort. The system processes information in two segments: a pretakeoff segment and a real-time segment. One-time inputs of ambient conditions and airplane configuration information are used in the pretakeoff segment to generate scheduled performance data. The real-time segment uses the scheduled performance data, runway length data and transducer measured parameters to monitor the performance of the airplane throughout the takeoff roll. An important feature of this segment is that it updates the estimated runway rolling friction coefficient. Airplane performance predictions also reflect changes in headwind occurring as the takeoff roll progresses. The system displays the position of the airplane on the runway, indicating runway used and runway available, summarizes the critical information into a situation advisory flag, flags engine failures and off-nominal acceleration performance, and indicates where on the runway particular events such as decision speed (V sub 1), rotation speed (V sub R) and expected stop points will occur based on actual or predicted performance. The display also indicates airspeed, wind vector, engine pressure ratios, second segment climb speed, and balanced field length (BFL). The system detects performance deficiencies by comparing the airplane's present performance with a predicted nominal performance based upon the given conditions.

Middleton, David B.↗

A high-temperature mixed potential CO gas sensor for in situ combustion control

An in situ, accurate and robust sensor that can sustain a high temperature of above 1000 °C is needed for on-site combustion monitoring because it can give real-time and local data to the control system to adjust the overall combustion efficiency. In this work, we find that nickel oxide (NiO) is a promising sensing material for CO which is a direct indicator of the status of the combustion process of a power plant. Under the conditions of 0.5–3% O 2 and 1000 °C, the fabricated yttrium-stabilized zirconia (YSZ)-based mixed potential sensor using porous NiO demonstrates good sensitivity to CO, showing a signal as high as 36 mV to 1000 ppm CO. The effects of gas transport, structure and geometry of the NiO electrode on the sensing performance are studied. Results show that fast gas transport is much beneficial to improved sensitivity. NiO having a porous structure is much more sensitive to CO than that having a dense structure. But the t90 (time to achieve 90% final signal magnitude) of the former is much longer due to slower gas diffusion inside the pores. It's worth noting that the NiO sensor exhibits a positive relationship with the CO content, opposite to other reported results of mixed potential sensors to detect CO. We find that this might be due to the electrochemical reduction, instead of oxidation of CO during the interaction with NiO at 1000 °C. Selectivity tests on how CO 2 , CH 4 and steam affect CO sensing are also demonstrated. NiO is insensitive to even 10% CO 2 . CH 4 does not shift the average value of the CO sensing response. However, it makes the sensing signal fluctuate more intensively. 2% steam exerts a great influence on NiO sensitivity to CO: it magnifies the sensitivity of the porous NiO electrode to a low CO range of 0–100 ppm, but inhibits its sensitivity to a CO range of 100 ppm to 1000 ppm. Lastly, an 11 day stability test demonstrates the promising stability property of the proposed NiO-based YSZ sensor.

20 FOSSIL-FUELED POWER PLANTS↗

Secure Time Synchronization in Power Grids and Network HIL Synchrophasor Testing

Reliable and secure time synchronization underpins the monitoring and control functions of modern power grids. As GPS-based timing infrastructures grow more susceptible to spoofing and jamming, their vulnerabilities pose escalating risks to grid stability. This work investigates a secure, resilient timing framework that can serve as an alternative or redundant source for power grids, with a particular focus on synchrophasorbased applications. A candidate timing system architecture is evaluated to guarantee trustworthy time dissemination, even in degraded conditions. A network hardware-in-the-loop testing of two synchrophasors validates the concepts, demonstrating enhanced timing integrity, improved detection of timing anomalies, and sustained observability during adverse timing events.

Wu, Ori [ORNL] (ORCID:0000000326723410)↗

Metallic Fuel Performance Analysis for the European Sodium Fast Reactor (ESFR-SIMPLE): Analysis of metallic fuel performance using SAS4A/SASSYS-1 $-$ MFUEL

The European Sodium Fast Reactor - Safety by Innovative Monitoring, Power Level flexibility and Experimental research (ESFR-SIMPLE) project was initiated in 2022 and includes assessment of a metallic-fueled version of the ESFR concept. Argonne National Laboratory (ANL) has been partnering with the ESFR-SIMPLE project to share its expertise on metallic fueled SFR designs and support some of its analysis. This report focuses on metallic fuel behavior analysis for ESFR-SIMPLE design conditions under base irradiation and transients (ULOF and UTOP).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗