Search NASA⌕ Search

SEARCH · Search NASA

Results for “consistent filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Spectroscopic imaging of self-organization in high power impulse magnetron sputtering plasmas

Excitation and ionization conditions in traveling ionization zones of high power impulse magnetron sputtering plasmas were investigated using fast camera imaging through interference filters. The images, taken in end-on and side on views using light of selected gas and target atom and ion spectral lines, suggest that ionization zones are regions of enhanced densities of electrons, and excited atoms and ions. Excited atoms and ions of the target material (Al) are strongly concentrated near the target surface. Images from the highest excitation energies exhibit the most localized regions, suggesting localized Ohmic heating consistent with double layer formation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectroscopic imaging of self-organization in high power impulse magnetron sputtering plasmas

Excitation and ionization conditions in traveling ionization zones of high power impulse magnetron sputtering plasmas were investigated using fast camera imaging through interference filters. The images, taken in end-on and side-on views using light of selected gas and target atom and ion spectral lines, suggest that ionization zones are regions of enhanced densities of electrons, and excited atoms and ions. Excited atoms and ions of the target material (Al) are strongly concentrated near the target surface. Images from the highest excitation energies exhibit the most localized regions, suggesting localized Ohmic heating consistent with double layer formation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Calibration of the microcalorimeter spectrometer on-board the Hitomi (Astro-H) observatory (invited)

The Hitomi Soft X-ray Spectrometer (SXS) was a pioneering non-dispersive imaging x-ray spectrometer with 5 eV FWHM energy resolution, consisting of an array of 36 silicon-thermistor microcalorimeters at the focus of a high-throughput soft x-ray telescope. Here, the instrument enabled astrophysical plasma diagnostics in the 0.3–12 keV band. We introduce the SXS calibration strategy and corresponding ground calibration measurements that took place from 2012–2015, including both the characterization of the microcalorimeter array and measurements of the x-ray transmission of optical blocking filters.

47 OTHER INSTRUMENTATION↗

Ferromagnetic resonances in single-crystal yttrium iron garnet nanofilms fabricated by metal-organic decomposition

Tunable microwave and millimeter wave oscillators and bandpass filters with ultra-low phase noise play a critical role in electronic devices, including wireless communication, microelectronics, and quantum computing. Magnetic materials, such as yttrium iron garnet (YIG), possess ultra-low phase noise and a ferromagnetic resonance tunable up to tens of gigahertz. Here, we report structural and magnetic properties of single-crystal 60 and 130 nm-thick YIG films prepared by metal-organic decomposition epitaxy. These films, consisting of multiple homoepitaxially grown monolayers, are atomically flat and possess magnetic properties similar to those grown with liquid-phase epitaxy, pulsed laser deposition, and sputtering. Our approach does not involve expensive high-vacuum deposition systems and is a true low-cost alternative to current commercial techniques that have the potential to transform the industry.

Wang, Szu-Fan (Paul)↗

Target-specific optimization of four-dimensional cone beam computed tomography

Purpose: Under-sampling artifacts are a major problem in four-dimensional cone-beam computed tomography (4D-CBCT) and may compromise evaluation of target motion. Several studies have addressed scan parameter selection for minimizing under-sampling artifacts; however, the role of the target characteristics in scan parameter selection has not been investigated. In this work, the authors evaluated 4D-CBCT performance by assessing the accuracy of target motion measurements for various target sizes and motions. The results may serve as patient-specific guidelines for scan parameters selection in 4D-CBCT. Methods: The authors acquired 4D-CBCT scans of a moving phantom consisting of six water-filled sphere targets of sizes 10-37 mm, using various scan times ranging from 30 s to 3 min., setting the motion to 3-s and 6-s periods. The authors used automatic image registration to extract the target motion trajectories and evaluated these measurements for various target sizes and motions over various combinations of scan parameters including scan time, detector configuration, number of respiration phases, and reconstruction filters. Results: The most important object parameter to 4D-CBCT performance was the period of motion. Measurements for the 6-s motion were always systematically less accurate than measurements for the 3-s motion for 34 of 36 objects of various sizes and periods of motion. The 6-s motion required a greater scan time than the 3-s motion for equivalent measurement accuracy. The second most influential parameter was the target size. For the 3-s period of motion, objects larger than 13 mm were tracked with sub-millimeter accuracy with a 1-min scan time. For the 6-s period of motion, objects larger than 22-mm were tracked with sub-millimeter accuracy with a 1.5-min scan time. For all sizes and motions, temporal blurring was observed when the number of phases was fewer than 8. Offset detector configuration provided the same performance as centered detector except for small targets (20 mm.) at short scan times ({<=}1 min). Finally, reconstruction filtering and number of respiratory phases did not affect performance. Conclusions: Scan time should be set according to target size and motion. The authors have provided figures that provide the minimum scan time needed to achieve the particular motion measurement accuracy for a particular size and motion period.

60 APPLIED LIFE SCIENCES↗

Multi-Angle Snowflake Camera Instrument Handbook

The Multi-Angle Snowflake Camera (MASC) takes 9- to 37-micron resolution stereographic photographs of free-falling hydrometers from three angles, while simultaneously measuring their fall speed. Information about hydrometeor size, shape orientation, and aspect ratio is derived from MASC photographs. The instrument consists of three commercial cameras separated by angles of 36º. Each camera field of view is aligned to have a common single focus point about 10 cm distant from the cameras. Two near-infrared emitter pairs are aligned with the camera’s field of view within a 10-angular ring and detect hydrometeor passage, with the lower emitters configured to trigger the MASC cameras. The sensitive IR motion sensors are designed to filter out slow variations in ambient light. Fall speed is derived from successive triggers along the fall path. The camera exposure times are extremely short, in the range of 1/25,000th of a second, enabling the MASC to capture snowflake sizes ranging from 30 micrometers to 3 cm.

47 OTHER INSTRUMENTATION↗

Analysis of the Intrinsic Mid-infrared L band to Visible–Near-infrared Flux Ratios in Spectral Synthesis Models of Composite Stellar Populations

We analyze the intrinsic flux ratios of various visible–near-infrared filters with respect to 3.5 μm for simple and composite stellar populations (CSPs), and their dependence on age, metallicity, and star formation history (SFH). UV/optical light from stars is reddened and attenuated by dust, where different sightlines across a galaxy suffer varying amounts of extinction. Tamura et al. (2009) developed an approximate method to correct for dust extinction on a pixel-by-pixel basis, dubbed the “β{sub V}” method, by comparing the observed flux ratio to an empirical estimate of the intrinsic ratio of visible and ∼3.5 μm data. Through extensive modeling, we aim to validate the “β{sub V}” method for various filters spanning the visible through near-infrared wavelength range, for a wide variety of simple and CSPs. Combining Starburst99 and BC03 models, we built spectral energy distributions (SEDs) of simple (SSP) and composite (CSP) stellar populations for various realistic SFHs, while taking metallicity evolution into account. We convolve various 0.44–1.65 μm filter throughput curves with each model SED to obtain intrinsic flux ratios β{sub λ,0}. When unconstrained in redshift, the total allowed range of β{sub V,0} is 0.6–4.7, or almost a factor of eight. At known redshifts, and in particular at low redshifts (z ≲ 0.01), β{sub V,0} is predicted to span a narrow range of 0.6–1.9, especially for early-type galaxies (0.6–0.7), and is consistent with observed β{sub V} values. The β{sub λ} method can therefore serve as a first-order dust-correction method for large galaxy surveys that combine JWST (rest-frame 3.5 μm) and HST (rest-frame visible–near-IR) data.

79 ASTRONOMY AND ASTROPHYSICS↗

An ultrathin ionomer interphase for high efficiency lithium anode in carbonate based electrolyte

High coulombic efficiency and dendrite suppression in carbonate electrolytes remain challenges to the development of high-energy lithium ion batteries containing lithium metal anodes. Here we demonstrate an ultrathin (≤100 nm) lithium-ion ionomer membrane consisting of lithium-exchanged sulfonated polyether ether ketone embedded with polyhedral oligosilsesquioxane as a coating layer on copper or lithium for achieving efficient and stable lithium plating-stripping cycles in a carbonate-based electrolyte. Operando analyses and theoretical simulation reveal the remarkable ability of the ionomer coating to enable electric field homogenization over a considerably large lithium-plating surface. The membrane coating, serving as an artificial solid-electrolyte interphase filter in minimizing parasitic reactions at the electrolyte-electrode interface, enables dendrite-free lithium plating on copper with outstanding coulombic efficiencies at room and elevated (50 °C) temperatures. The membrane coated copper demonstrates itself as a promising current collector for manufacturing high-quality pre-plated lithium thin-film anode.

25 ENERGY STORAGE↗

Plant functional trait change across a warming tundra biome

Trait-based ecology promises to predict community assembly1–3, ecosystem function4–6, and responses to environmental change4,7 across spatial and temporal scales. At the global scale the majority of plant trait variation is explained by just two dimensions8, corresponding to resource acquisition9 and plant size10,11. However, it is unknown whether (1) globally established trait relationships are maintained across biomes, (2) species level relationships could be invalidated by trait variation within species, and (3) trait variation is independent of scale. We tested these questions at the cold extremes of life on earth using the largest tundra plant trait database ever compiled. Here we show we found that tundra plants exhibited a two-axis spectrum consistent with global findings, and demonstrated remarkable consistency in the range of resource acquisition traits, but not size traits, compared to global trait distributions. The majority of trait variation occurred at the species level, but within-species variation comprised an important component of variation at local scales (<10 km2) and at low species richness (<10 species), implying that.... Our findings indicate that the dimensions of functional trait space are maintained in the coldest ecosystems on the planet despite strong environmental filtering of plant size, but that a greater focus on within-species trait variation is required to predict trait change at the community scale.

Bjorkman, Anne D.↗

AI-accelerated protein-ligand docking for SARS-CoV-2 is 100-fold faster with no significant change in detection

Protein-ligand docking is a computational method for identifying drug leads. The method is capable of narrowing a vast library of compounds down to a tractable size for downstream simulation or experimental testing and is widely used in drug discovery. While there has been progress in accelerating scoring of compounds with artificial intelligence, few works have bridged these successes back to the virtual screening community in terms of utility and forward-looking development. We demonstrate the power of high-speed ML models by scoring 1 billion molecules in under a day (50 k predictions per GPU seconds). We showcase a workflow for docking utilizing surrogate AI-based models as a pre-filter to a standard docking workflow. Our workflow is ten times faster at screening a library of compounds than the standard technique, with an error rate less than 0.01% of detecting the underlying best scoring 0.1% of compounds. Our analysis of the speedup explains that another order of magnitude speedup must come from model accuracy rather than computing speed. In order to drive another order of magnitude of acceleration, we share a benchmark dataset consisting of 200 million 3D complex structures and 2D structure scores across a consistent set of 13 million “in-stock” molecules over 15 receptors, or binding sites, across the SARS-CoV-2 proteome. We believe this is strong evidence for the community to begin focusing on improving the accuracy of surrogate models to improve the ability to screen massive compound libraries 100 × or even 1000 × faster than current techniques and reduce missing top hits. The technique outlined aims to be a fast drop-in replacement for docking for screening billion-scale molecular libraries.

59 BASIC BIOLOGICAL SCIENCES↗

Non-Equilibrium Dynamics Contribute to Ion Selectivity in the KcsA Channel

The ability of biological ion channels to conduct selected ions across cell membranes is critical for the survival of both animal and bacterial cells. Numerous investigations of ion selectivity have been conducted over more than 50 years, yet the mechanisms whereby the channels select certain ions and reject others are not well understood. Here we report a new application of Jarzynski’s Equality to investigate the mechanism of ion selectivity using non-equilibrium molecular dynamics simulations of Na + and K + ions moving through the KcsA channel. The simulations show that the selectivity filter of KcsA adapts and responds to the presence of the ions with structural rearrangements that are different for Na + and K + . These structural rearrangements facilitate entry of K + ions into the selectivity filter and permeation through the channel, and rejection of Na + ions. A mechanistic model of ion selectivity by this channel based on the results of the simulations relates the structural rearrangement of the selectivity filter to the differential dehydration of ions and multiple-ion occupancy and describes a mechanism to efficiently select and conduct K + . Estimates of the K + /Na + selectivity ratio and steady state ion conductance for KcsA from the simulations are in good quantitative agreement with experimental measurements. This model also accurately describes experimental observations of channel block by cytoplasmic Na + ions, the ‘‘punch through’’ relief of channel block by cytoplasmic positive voltages, and is consistent with the knock-on mechanism of ion permeation.

59 BASIC BIOLOGICAL SCIENCES↗

The Infrared Medium-deep Survey. III. Survey of Luminous Quasars at 4.7 ≤ z ≤ 5.4

We present the first results of our survey for high-redshift quasars at 5≲z≲5.7. The search for quasars in this redshift range has been known to be challenging due to the limitations of the filter sets used in previous studies. We conducted a quasar survey for two specific redshift ranges, 4.60 ≤ z ≤ 5.40 and 5.50 ≤ z ≤ 6.05, using multi-wavelength data that include observations made with custom-designed filters, is and iz. Using these filters and a new selection technique, we were able to reduce the fraction of interlopers. Through optical spectroscopy, we confirmed six quasars at 4.7 ≤ z ≤ 5.4 with −27.4<M{sub 1450}<−26.4 that recently were discovered independently by another group. We estimated black hole masses and Eddington ratios of four of these quasars from optical and near-infrared spectra, and found that these quasars are undergoing nearly Eddington-limited accretion that is consistent with the rapid growth of supermassive black holes in luminous quasars at z ∼ 5.

79 ASTRONOMY AND ASTROPHYSICS↗

NEAR-ULTRAVIOLET PROPERTIES OF A LARGE SAMPLE OF TYPE Ia SUPERNOVAE AS OBSERVED WITH THE Swift UVOT

We present ultraviolet (UV) and optical photometry of 26 Type Ia supernovae (SNe Ia) observed from 2005 March to 2008 March with the NASA Swift Ultraviolet and Optical Telescope (UVOT). The dataset consists of 2133 individual observations, making it by far the most complete study of the UV emission from SNe Ia to date. Grouping the SNe into three subclasses as derived from optical observations, we investigate the evolution of the colors of these SNe, finding a high degree of homogeneity within the normal subclass, but dramatic differences between that group and the subluminous and SN 2002cx-like groups. For the normal events, the redder UV filters on UVOT (u, uvw1) show more homogeneity than do the bluer UV filters (uvm2, uvw2). Searching for purely UV characteristics to determine existing optically based groupings, we find the peak width to be a poor discriminant, but we do see a variation in the time delay between peak emission and the late, flat phase of the light curves. The UV light curves peak a few days before the B band for most subclasses (as was previously reported by Jha et al.), although the SN 2002cx-like objects peak at a very early epoch in the UV. That group also features the bluest emission observed among SNe Ia. As the observational campaign is ongoing, we discuss the critical times to observe, as determined by this study, in order to maximize the scientific output of future observations.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-AB-BRB-09: Real Time In Vivo Scintillating Fiber Array Detector for Medical LINACS

Purpose: An in vivo transmission scintillation fiber detector was developed to monitor patient treatment in real time for the enhancement of patient safety and treatment accuracy. The detector system is capable of monitoring each pulse from a medical LINAC during treatment to determine the dose delivered as treatment progresses. Methods: The detector system consists of 60 parallel scintillating fibers coupled to fast data processing optoelectronics that can monitor the beam fluence in real time. Each 2.5mm{sup 2} square fiber is aligned with an MLC leaf pair and is long enough to capture a 40cm field. The fibers are embedded within a water equivalent polymer substrate that is secured in the LINAC accessory tray. The fibers are coupled to high speed photosensors and front end amplifiers that filter noise and pass each pulse to a high speed analog-to-digital converter. The system components are capable of detecting pulse repetition times shorter than what is delivered by a medical LINAC to ensure true real time data acquisition. Results: The system was able to capture and record the signal from each linac pulse and display the information in real time with no pulse pile up. It was found that the fiber array attenuates 2.65% of the beam which can easily be compensated for in treatment planning. The fibers responded linearly with dose, are independent of clinical beam energies, and are independent of dose rate. Calibration of the system was performed as a function of beam energy, beam size, dose rate, and monitor units to optimize beam fluence error detection. Conclusion: The detector system presented provides true real time in vivo beam monitoring to enhance patient safety and treatment delivery accuracy. Furthermore, the detector can be used for current patient specific QA.

60 APPLIED LIFE SCIENCES↗

Ex Situ Catalytic Fast Pyrolysis of Lignocellulosic Biomass to Hydrocarbon Fuels: 2018 State of Technology and Future Research

This report will update modeled costs for a fixed bed ex situ catalytic fast pyrolysis process for the conversion of biomass to liquid hydrocarbon fuels based on recent bench-scale experimental results. It will also update previously published information for this conversion pathway in the DOE Bioenergy Technologies Office 2016 Multi-Year Program Plan with current understanding of research goals achievable by 2022 and associated modeled cost reductions. All costs will be updated to a consistent set of assumptions in 2016 dollars.

09 BIOMASS FUELS↗

Voltage Gated Ion Channel Function: Gating, Conduction, and the Role of Water and Protons

Ion channels, which are found in every biological cell, regulate the concentration of electrolytes, and are responsible for multiple biological functions, including in particular the propagation of nerve impulses. The channels with the latter function are gated (opened) by a voltage signal, which allows Na+ into the cell and K+ out. These channels have several positively charged amino acids on a transmembrane domain of their voltage sensor, and it is generally considered, based primarily on two lines of experimental evidence, that these charges move with respect to the membrane to open the channel. At least three forms of motion, with greatly differing extents and mechanisms of motion, have been proposed. There is a “gating current”, a capacitative current preceding the channel opening, that corresponds to several charges (for one class of channel typically 12–13) crossing the membrane field, which may not require protein physically crossing a large fraction of the membrane. The coupling to the opening of the channel would in these models depend on the motion. The conduction itself is usually assumed to require the “gate” of the channel to be pulled apart to allow ions to enter as a section of the protein partially crosses the membrane, and a selectivity filter at the opposite end of the channel determines the ion which is allowed to pass through. We will here primarily consider K+ channels, although Na+ channels are similar. We propose that the mechanism of gating differs from that which is generally accepted, in that the positively charged residues need not move (there may be some motion, but not as gating current). Instead, protons may constitute the gating current, causing the gate to open; opening consists of only increasing the diameter at the gate from approximately 6 Å to approximately 12 Å. We propose in addition that the gate oscillates rather than simply opens, and the ion experiences a barrier to its motion across the channel that is tuned by the water present within the channel. Our own quantum calculations as well as numerous experiments of others are interpreted in terms of this hypothesis. It is also shown that the evidence that supports the motion of the sensor as the gating current can also be consistent with the hypothesis we present.

Environmental Molecular Sciences Laboratory↗

Pixel color magnitude diagrams for semi-resolved stellar populations: the star formation history of regions within the disk and bulge of M31

The analysis of stellar populations has, by and large, been developed for two limiting cases: spatially resolved stellar populations in the color–magnitude diagram, and integrated light observations of distant systems. In between these two extremes lies the semi-resolved regime, which encompasses a rich and relatively unexplored realm of observational phenomena. Here we develop the concept of pixel color–magnitude diagrams (pCMDs) as a powerful technique for analyzing stellar populations in the semi-resolved regime. pCMDs show the distribution of imaging data in the plane of pixel luminosity versus pixel color. A key feature of pCMDs is that they are sensitive to all stars, including both the evolved giants and the unevolved main sequence stars. An important variable in this regime is the mean number of stars per pixel, N{sub pix}. Simulated pCMDs demonstrate a strong sensitivity to the star formation history (SFH) and have the potential to break degeneracies between age, metallicity and dust based on two filter data for values of N{sub pix} up to at least 10{sup 4}. We extract pCMDs from Hubble Space Telescope optical imaging of M31 and derive SFHs with seven independent age bins from 10{sup 6} to 10{sup 10} year for both the crowded disk and bulge regions (where N{sub pix}≈30--10{sup 3}). From analyzing a small region of the disk we find a SFH that is smooth and consistent with an exponential decay timescale of 4 Gyr. The bulge SFH is also smooth and consistent with a 2 Gyr decay timescale. pCMDs will likely play an important role in maximizing the science returns from next generation ground and space-based facilities.

79 ASTRONOMY AND ASTROPHYSICS↗

Detection of Exocometary CO within the 440 Myr Old Fomalhaut Belt: A Similar CO+CO{sub 2} Ice Abundance in Exocomets and Solar System Comets

Recent Atacama Large Millimeter/submillimeter Array observations present mounting evidence for the presence of exocometary gas released within Kuiper Belt analogs around nearby main-sequence stars. This represents a unique opportunity to study their ice reservoir at the younger ages when volatile delivery to planets is most likely to occur. We here present the detection of CO J = 2-1 emission colocated with dust emission from the cometary belt in the 440 Myr old Fomalhaut system. Through spectrospatial filtering, we achieve a 5.4σ detection and determine that the ring’s sky-projected rotation axis matches that of the star. The CO mass derived ((0.65--42)×10{sup −7} M{sub ⊕}) is the lowest of any circumstellar disk detected to date and must be of exocometary origin. Using a steady-state model, we estimate the CO+CO{sub 2} mass fraction of exocomets around Fomalhaut to be between 4.6% and 76%, consistent with solar system comets and the two other belts known to host exocometary gas. This is the first indication of a similarity in cometary compositions across planetary systems that may be linked to their formation scenario and is consistent with direct interstellar medium inheritance. In addition, we find tentative evidence that (49±27)% of the detected flux originates from a region near the eccentric belt’s pericenter. If confirmed, the latter may be explained through a recent impact event or CO pericenter glow due to exocometary release within a steady-state collisional cascade. In the latter scenario, we show how the azimuthal dependence of the CO release rate leads to asymmetries in gas observations of eccentric exocometary belts.

79 ASTRONOMY AND ASTROPHYSICS↗