Search NASA⌕ Search

SEARCH · Search NASA

Results for “correlation coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Application of mixed kernels function (MKF) based support vector regression model (SVR) for CO 2 – Reservoir oil minimum miscibility pressure prediction

Carbon dioxide (CO 2 ) injection into oil reservoirs is considered a mature enhanced oil recovery (EOR) technique for conventional reservoirs. The local displacement efficiency of the CO 2 -EOR process is highly dependent on the minimum miscibility pressure (MMP), estimating this parameter is critical to design of the CO 2 injection process. Traditional empirical methods to test the CO 2 -oil MMP are time consuming and expensive; derived correlations are fast but not accurate. Therefore, an efficient and reliable method to determine MMP is beneficial. Here in this study, a mixed kernels function (MKF) based support vector regression (SVR) model was developed and used to predict the MMP for both pure and impure CO 2 injection cases. Four parameters were chosen as input parameters: (1) reservoir temperature; (2) average critical temperature; (3) molecular weight of pentane plus (C 5+ ) fraction of crude oil, and; (4) the ratio of volatile components to intermediate components in crude oil. MMP was selected as the desired output parameter to train and test this newly developed model. The performance of basic kernels function based SVR model is compared with that of this newly developed MKF-SVR model. The well-trained MFK-SVR was compared with three well-established published correlations, demonstrated the highest correlation coefficient (R of 0.9381), lowest root mean square error (RMSE of 1.9151), smallest average absolute error (AAE of 1.1406) and maximum absolute error (MAE of 4.6291). We believe that the proposed MFK-SVM model is a more reliable and stable regression model to predict MMP. In addition, a sensitivity analysis was conducted to evaluate the physical correctness. It indicates that the predicted results from the newly developed model are in excellent agreement with previous empirical work.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aerosol emissions from water-lean solvents for post-combustion CO 2 capture

Advanced water-lean solvents (WLS) for post-combustion CO 2 capture have been gaining interest due to their ability to reduce the parasitic penalty from energy needed for solvent regeneration. Commercial implementation of these novel CO 2 capture technologies hinges on successful control of amine emissions. RTI conducted a parametric study of fundamental and operational variables influence on overall amine aerosol and vapor emissions from our water-lean solvent eCO 2 Sol™ using our 6-kW equivalent bench-scale gas absorption system. The parametric testing used a simulated flue gas with 15 % CO 2 , 2.3–4.2 % H 2 O, and 0–6 ppm sulfite (SO 3 ) to examine the impact of the presence of aerosols to the capture performance and amine emissions from the system. The SO 3 reacts with water in the flue gas to create H 2 SO 4 , which forms liquid aerosol droplets and provide nucleation sites for growth of aerosols. Scanning Mobility Particle Sizer and Aerodynamic Particle Sizer instruments monitored the aerosol particle size distribution. Parametric testing results suggested that the presence of the aerosols in the flue gas could increase the overall amine emissions by 10X compared to the baseline emissions from WLS’s vapor pressure. Principal component analysis (PCA) and projection to latent squares (PLS) developed models to predict the aerosol-based amine emissions from process data. The predictive PLS model had a correlation coefficient (Q 2 ) of 0.92 and could predict the aerosol-based emissions from the NAS process with ±15 % accuracy (average absolute deviation, AAD). The PLS regression model also identified key variables affecting aerosol-based emissions from WLS.

42 ENGINEERING↗

Inferences About Prostate Intrafraction Motion From Pre- and Posttreatment Volumetric Imaging

Purpose: To evaluate the ability of rectal filling, bladder filling, and prostate localization from pre- and posttreatment volumetric imaging to predict prostate intrafraction motion. Methods and Materials: Pre- and posttreatment cone beam computed tomography images (CBCTs) and intrafractional kV fluoroscopy were acquired at each fraction for 20 prostate patients in supine position, totaling 374 fractions available for analysis. Rectal and bladder filling status were evaluated for each CBCT, and correlation with prostate intrafraction motion measured from kV fluoroscopy was performed. The accuracy of pre and posttreatment prostate localization to predict intrafraction motion was evaluated. Results: Rectal filling status was a significant predictor of prostate intrafraction motion (p <0.001), and gas volume was correlated with the maximum vector displacement at MV delivery with a correlation coefficient (cc) of 0.37 and p <0.001. Prostate motion was greater for patients who consistently had gas volume >0.5 cm{sup 3} within the imaged region (cc = 0.52, p = 0.028). A weak relationship was found between bladder filling and posterior prostate drift for fractions with gas volume {<=}0.5 cm{sup 3} (cc = -0.17, p = 0.046). The sensitivity of detecting a 3-, 5-, and 7-mm excursion at MV delivery using posttreatment imaging was 76%, 75%, and 81% respectively. Conclusions: Rectal filling is a significant predictor of prostate intrafraction motion, whereas bladder filling is of limited usefulness. Pre- and posttreatment localization can provide a reasonable estimate of prostate motion during MV delivery when intrafraction localization is not available, with an error of 95% within 3.1 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

B1 Sequence-Based Real-Time Quantitative PCR: A Sensitive Method for Direct Measurement of Mouse Plasma DNA Levels After Gamma Irradiation

Purpose: Current biodosimetric techniques for determining radiation exposure have inherent delays, as well as quantitation and interpretation limitations. We have identified a new technique with the advantage of directly measuring circulating DNA by amplifying inter-B1 regions in the mouse genome, providing a sensitive method for quantitating plasma DNA. Methods and Materials: Real-time quantitative polymerase chain reaction (PCR) was used to detect levels of DNA by amplifying inter-B1 genomic DNA in plasma samples collected at 0-48 h from mice receiving 0-10 Gy total- or partial-body irradiation ({sup 137}Cs {gamma}-ray source at {approx}1.86 Gy/min; homogeneity: {+-} 6.5%). Results: The correlation coefficient between DNA levels and the threshold cycle value (C{sub T}) was 0.996, and the average recoveries of DNA in the assay were 87%. This assay revealed that when BALB/c mice were exposed to 10 Gy total-body irradiation (TBI), plasma DNA levels gradually increased beginning at 3 h after irradiation, peaked at 9 h, and returned to baseline within 48 h. Increased plasma DNA levels were also detected following upper-torso or lower-torso partial-body irradiation; however, TBI approximately doubled those plasma DNA levels at the same radiation dose. This technique therefore reflects total body cell damage. The advantages of this assay are that DNA extraction is not required, the assay is highly sensitive (0.002 ng), and results can be obtained within 2.5 h after collection of plasma samples. Conclusions: A radiation dose-dependent increase of plasma DNA was observed in the dose range from 2 to 10 Gy, suggesting that plasma DNA may be a useful radiation biomarker and adjunct to existing cell-based assays.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single Versus Customized Treatment Planning for Image-guided High-Dose-Rate Brachytherapy for Cervical Cancer: Dosimetric Comparison and Predicting Factor for Organs at Risk Overdose With Single Plan Approach

Purpose: To compare the dose distribution between customized planning (CP) and adopting a single plan (SP) in multifractionated high-dose-rate brachytherapy and to establish predictors for the necessity of CP in a given patient. Methods and Materials: A total of 50 computed tomography-based plans for 10 patients were evaluated. Each patient had received 6 Gy for five fractions. The clinical target volume and organs at risk (i.e., rectum, bladder, sigmoid, and small bowel) were delineated on each computed tomography scan. For the SP approach, the same dwell position and time was used for all fractions. For the CP approach, the dwell position and time were reoptimized for each fraction. Applicator position variation was determined by measuring the distance between the posterior bladder wall and the tandem at the level of the vaginal fornices. Results: The organs at risk D{sub 2cc} (dose to 2 cc volume) was increased with the SP approach. The dose variation was statistically similar between the tandem and ring and tandem and ovoid groups. The bladder D{sub 2cc} dose was 81.95-105.42 Gy{sub 2} for CP and 82.11-122.49 Gy{sub 2} for SP. In 5 of the 10 patients, the bladder would have been significantly overdosed with the SP approach. The variation of the posterior bladder wall distance from that in the first fraction was correlated with the increase in the bladder D{sub 2cc} (SP/CP), with a correlation coefficient of -0.59. Conclusion: Our results support the use of CP instead of the SP approach to help avoid a significant overdose to the bladder. This is especially true for a decrease in the posterior wall distance of {>=}0.5 cm compared with that in the first fraction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative Analysis of Extracapsular Extension of Metastatic Lymph Nodes and its Significance in Radiotherapy Planning in Head and Neck Squamous Cell Carcinoma

Purpose: We performed a histopathologic analysis to assess the extent of the extracapsular extension (ECE) beyond the capsule of metastatic lymph nodes (LN) in head and neck cancer to determine appropriate clinical target volume (CTV) expansions. Methods and Materials: All tumor-positive LN of 98 patients who underwent a neck dissection with evidence of ECE in at least one LN were analyzed by a single pathologist. The largest diameters of all LN, and in the case of ECE, the maximal linear distance, from the capsule to the farthest extent of tumor or tumoral reaction were recorded. Results: A total of 231 LN with ECE and 200 tumor-positive LN without ECE were analyzed. The incidence of ECE was associated with larger LN size (p < 0.001). Of all tumor-positive LN with a diameter of < 10 mm or < 5 mm, 105/220 (48%) nodes or 17/59 (29%) nodes, respectively, showed evidence of ECE. The mean and median extent values of ECE were 2 and 1 mm (range, 1-10 mm) and the ECE was <= 5 mm in 97% and <= 3 mm in 91% of the LN, respectively. Overall, the extent of ECE was significantly correlated with larger LN size (Spearman's correlation coefficient = 0.21; p = 0.001). Conclusions: The incidence of ECE is associated with larger LN size. However, ECE is found in a substantial number of LN with a diameter of < 10 mm. The use of 10-mm CTV margins around the gross tumor volume seems appropriate to account for ECE in radiotherapy planning of head and neck cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

{sup 18}F-FDG PET Definition of Gross Tumor Volume for Radiotherapy of Lung Cancer: Is the Tumor Uptake Value-Based Approach Appropriate for Lymph Node Delineation?

Purpose: Positron emission tomography (PET) with the glucose analogue [18F] fluoro-2-deoxy-D-glucose ({sup 18}F-FDG-PET) has been used in radiation treatment planning for non-small-cell carcinoma. To date, lymph nodes have been contoured according to the uptake of the tumor. This prospective study was performed to evaluate if nodal volume delineates according to FDG uptake within the primary tumor (PET-GTVnt) is suitable for nodal target volume delineation or if individualized nodal FDG uptake measure (PET-GTVnn) is necessary to better nodal target definition. Methods and Materials: Forty cases, who underwent a diagnostic {sup 18}F-FDG PET/computed tomography (CT) scan, were included. Two PET-based GTVs for each lymph node were contoured and compared. First, we used an isocontour of 40% of the maximum tumor uptake (PET-GTVnt). Second, an isocontour of 40% of the maximum uptake of each node (PET-GTVnn) was employed. To avoid interobserver variability, this was carried out by the same radiation oncologist. Afterwards, the difference between both lymph node volumes was plotted against the ratio of the maximum uptakes (I{sub n}/I{sub t}) in a linear regression analysis. Results: Compared with CT-based lymph node volume (CT-GTVn), the intraclass correlation coefficient of PET-GTVnn was higher than the coefficient of PET-GTVnt (p < 0.001). All cases could be divided into four groups: undetected (17.5%), detected but overestimated (10%), detected but underestimated (35%), and correctly detected (37.5%). Conclusions: If a method of automatic delineation shall be applied, this method must be applied to every lesion separately. However, to facilitate the delineation in daily practice, when I{sub n}/I{sub t} is {<=}25%, lymph nodes could be delineated in accordance with tumor uptake, keeping an absolute difference in radii <5 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prostate Intrafraction Motion Assessed by Simultaneous kV Fluoroscopy at MV Delivery II: Adaptive Strategies

Purpose: To investigate potential benefits of adaptive strategies for managing prostate intrafractional uncertainties when interfraction motion is corrected online. Methods and Materials: Prostate intrafraction motion was measured using kV fluoroscopy during MV delivery for 571 fractions from 30 hypofractionated radiotherapy patients. We evaluated trending over treatment course using analysis of variance statistics, and we evaluated the ability to correct patient-specific systematic error and apply patient-specific statistical margins after 2 to 15 fractions to compensate 90% of motion. We also evaluated the ability to classify patients into small- and large-motion subgroups based on the first 2 to 20 fractions using discriminant analysis. Results: No time trend was observed over treatment course, and intrafraction motion was patient specific (p < 0.0001). Systematic error in the first week correlated well with that in subsequent weeks, with correlation coefficients of 0.53, 0.50, and 0.41 in right-left (RL), anterior-posterior (AP), and superior-inferior (SI), respectively. After 5 fractions, the adaptive strategy resulted in average margin reductions of 0.3, 0.7, and 0.7 mm in RL, AP, and SI, respectively, with margins ranging from 1 to 3.2 mm in RL, 2 to 7.0 mm in AP, and 2 to 6.6 mm in SI. By contrast, population margins to include the same percentage of motion were 1.7, 4.0, and 4.1 mm. After 2 and 5 fractions, patients were classified into small- and large-motion groups with {approx}77% and {approx}83% accuracy. Conclusions: Adaptive strategies are feasible and beneficial for intrafraction motion management in prostate cancer online image guidance. Patients may be classified into large- and small-motion groups in early fractions using discriminant analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance of a Novel Repositioning Head Frame for Gamma Knife Perfexion and Image-Guided Linac-Based Intracranial Stereotactic Radiotherapy

Purpose: To evaluate the geometric positioning and immobilization performance of a vacuum bite-block repositioning head frame (RHF) system for Perfexion (PFX-SRT) and linac-based intracranial image-guided stereotactic radiotherapy (SRT). Methods and Materials: Patients with intracranial tumors received linac-based image-guided SRT using the RHF for setup and immobilization. Three hundred thirty-three fractions of radiation were delivered in 12 patients. The accuracy of the RHF was estimated for linac-based SRT with online cone-beam CT (CBCT) and for PFX-SRT with a repositioning check tool (RCT) and offline CBCT. The RCT's ability to act as a surrogate for anatomic position was estimated through comparison to CBCT image matching. Immobilization performance was evaluated daily with pre- and postdose delivery CBCT scans and RCT measurements. Results: The correlation coefficient between RCT- and CBCT-reported displacements was 0.59, 0.75, 0.79 (Right, Superior, and Anterior, respectively). For image-guided linac-based SRT, the mean three-dimensional (3D) setup error was 0.8 mm with interpatient ({Sigma}) and interfraction ({sigma}) variations of 0.1 and 0.4 mm, respectively. For PFX-SRT, the initial, uncorrected mean 3D positioning displacement in stereotactic coordinates was 2.0 mm, with {Sigma} = 1.1 mm and {sigma} = 0.8 mm. Considering only RCT setups <1mm (PFX action level) the mean 3D positioning displacement reduced to 1.3 mm, with {Sigma} = 0.9 mm and {sigma} = 0.4 mm. The largest contributing systematic uncertainty was in the superior-inferior direction (mean displacement = -0.5 mm; {Sigma} = 0.9 mm). The largest mean rotation was 0.6{sup o} in pitch. The mean 3D intrafraction motion was 0.4 {+-} 0.3 mm. Conclusion: The RHF provides excellent immobilization for intracranial SRT and PFX-SRT. Some small systematic uncertainties in stereotactic positioning exist and must be considered when generating PFX-SRT treatment plans. The RCT provides reasonable surrogacy for internal anatomic displacement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Liver Tumor Motion With and Without Abdominal Compression Using Cine-Magnetic Resonance Imaging

Purpose: Abdominal compression (AC) can be used to reduce respiratory liver motion in patients undergoing liver stereotactic body radiotherapy. The purpose of the present study was to measure the changes in three-dimensional liver tumor motion with and without compression using cine-magnetic resonance imaging. Patients and Methods: A total of 60 patients treated as a part of an institutional research ethics board-approved liver stereotactic body radiotherapy protocol underwent cine T2-weighted magnetic resonance imaging through the tumor centroid in the coronal and sagittal planes. A total of 240 cine-magnetic resonance imaging sequences acquired at one to three images each second for 30-60 s were evaluated using an in-house-developed template matching tool (based on the coefficient correlation) to measure the magnitude of the tumor motion. The average tumor edge displacements were used to determine the magnitude of changes in the caudal-cranial (CC) and anteroposterior (AP) directions, with and without AC. Results: The mean tumor motion without AC of 11.7 mm (range, 4.8-23.3) in the CC direction was reduced to 9.4 mm (range, 1.6-23.4) with AC. The tumor motion was reduced in both directions (CC and AP) in 52% of the patients and in a single direction (CC or AP) in 90% of the patients. The mean decrease in tumor motion with AC was 2.3 and 0.6 mm in the CC and AP direction, respectively. Increased motion occurred in one or more directions in 28% of patients. Clinically significant (>3 mm) decreases were observed in 40% and increases in <2% of patients in the CC direction. Conclusion: AC can significantly reduce three-dimensional liver tumor motion in most patients, although the magnitude of the reduction was smaller than previously reported.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accurate Analysis of the Change in Volume, Location, and Shape of Metastatic Cervical Lymph Nodes During Radiotherapy

Purpose: To establish a method for the accurate acquisition and analysis of the variations in tumor volume, location, and three-dimensional (3D) shape of tumors during radiotherapy in the era of image-guided radiotherapy. Methods and Materials: Finite element models of lymph nodes were developed based on computed tomography (CT) images taken before the start of treatment and every week during the treatment period. A surface geometry map with a volumetric scale was adopted and used for the analysis. Six metastatic cervical lymph nodes, 3.5 to 55.1 cm{sup 3} before treatment, in 6 patients with head and neck carcinomas were analyzed in this study. Three fiducial markers implanted in mouthpieces were used for the fusion of CT images. Changes in the location of the lymph nodes were measured on the basis of these fiducial markers. Results: The surface geometry maps showed convex regions in red and concave regions in blue to ensure that the characteristics of the 3D tumor geometries are simply understood visually. After the irradiation of 66 to 70 Gy in 2 Gy daily doses, the patterns of the colors had not changed significantly, and the maps before and during treatment were strongly correlated (average correlation coefficient was 0.808), suggesting that the tumors shrank uniformly, maintaining the original characteristics of the shapes in all 6 patients. The movement of the gravitational center of the lymph nodes during the treatment period was everywhere less than {+-}5 mm except in 1 patient, in whom the change reached nearly 10 mm. Conclusions: The surface geometry map was useful for an accurate evaluation of the changes in volume and 3D shapes of metastatic lymph nodes. The fusion of the initial and follow-up CT images based on fiducial markers enabled an analysis of changes in the location of the targets. Metastatic cervical lymph nodes in patients were suggested to decrease in size without significant changes in the 3D shape during radiotherapy. The movements of the gravitational center of the lymph nodes were almost all less than {+-}5 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Esophageal Stenosis Associated With Tumor Regression in Radiotherapy for Esophageal Cancer: Frequency and Prediction

Purpose: To determine clinical factors for predicting the frequency and severity of esophageal stenosis associated with tumor regression in radiotherapy for esophageal cancer. Methods and Materials: The study group consisted of 109 patients with esophageal cancer of T1-4 and Stage I-III who were treated with definitive radiotherapy and achieved a complete response of their primary lesion at Kyushu University Hospital between January 1998 and December 2007. Esophageal stenosis was evaluated using esophagographic images within 3 months after completion of radiotherapy. We investigated the correlation between esophageal stenosis after radiotherapy and each of the clinical factors with regard to tumors and therapy. For validation of the correlative factors for esophageal stenosis, an artificial neural network was used to predict the esophageal stenotic ratio. Results: Esophageal stenosis tended to be more severe and more frequent in T3-4 cases than in T1-2 cases. Esophageal stenosis in cases with full circumference involvement tended to be more severe and more frequent than that in cases without full circumference involvement. Increases in wall thickness tended to be associated with increases in esophageal stenosis severity and frequency. In the multivariate analysis, T stage, extent of involved circumference, and wall thickness of the tumor region were significantly correlated to esophageal stenosis (p = 0.031, p < 0.0001, and p = 0.0011, respectively). The esophageal stenotic ratio predicted by the artificial neural network, which learned these three factors, was significantly correlated to the actual observed stenotic ratio, with a correlation coefficient of 0.864 (p < 0.001). Conclusion: Our study suggested that T stage, extent of involved circumference, and esophageal wall thickness of the tumor region were useful to predict the frequency and severity of esophageal stenosis associated with tumor regression in radiotherapy for esophageal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Assessment of Optimal Individual Position (Prone Versus Supine) for Breast Radiotherapy: Volumetric and Dosimetric Correlations in 100 Patients

Purpose: Damage to heart and lung from breast radiotherapy is associated with increased cardiovascular mortality and lung cancer development. We conducted a prospective study to evaluate which position is best to spare lung and heart from radiotherapy exposure. Methods and Materials: One hundred consecutive Stage 0-IIA breast cancer patients consented to participate in a research trial that required two computed tomography simulation scans for planning both supine and prone positions. The optimal position was defined as that which best covered the contoured breast and tumor bed while it minimized critical organ irradiation, as quantified by the in-field heart and lung volume. The trial was designed to plan the first 100 patients in each position to study correlations between in-field volumes of organs at risk and dose. Results: Fifty-three left and 47 right breast cancer patients were consecutively accrued to the trial. In all patients, the prone position was optimal for sparing lung volume compared to the supine setup (mean lung volume reduction was 93.5 cc for right and 103.6 cc for left breast cancer patients). In 46/53 (87%) left breast cancer patients best treated prone, in-field heart volume was reduced by a mean of 12 cc and by 1.8 cc for the other 7/53 (13%) patients best treated supine. As predicted, supine-prone differences in in-field volume and mean dose of heart and lung were highly correlated (Spearman's correlation coefficient for left breast cancer patients was 0.90 for heart and 0.94 for lung and 0.92 for right breast cancer patients for lung). Conclusions: Prone setup reduced the amount of irradiated lung in all patients and reduced the amount of heart volume irradiated in 87% of left breast cancer patients. In-field organ volume is a valid surrogate for predicting dose; the trial continued to the planned target of 400.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Risk Factors of Symptomatic Communicating Hydrocephalus After Stereotactic Radiosurgery for Unilateral Vestibular Schwannoma: The Implication of Brain Atrophy

Purpose: To identify the effect of brain atrophy on the development of symptomatic communicating hydrocephalus (SCHCP) after stereotactic radiosurgery (SRS) for sporadic unilateral vestibular schwannomas (VS). Methods and Materials: A total of 444 patients with VS were treated with SRS as a primary treatment. One hundred eighty-one patients (40.8%) were male, and the mean age of the patients was 53 {+-} 13 years (range, 11-81 years). The mean follow-up duration was 56.8 {+-} 35.8 months (range, 12-160 months). The mean tumor volume was 2.78 {+-} 3.33 cm{sup 3} (range, 0.03-23.30 cm{sup 3}). The cross-sectional area of the lateral ventricles (CALV), defined as the combined area of the lateral ventricles at the level of the mammillary body, was measured on coronal T1-weighted magnetic resonance images as an indicator of brain atrophy. Results: At distant follow-up, a total of 25 (5.6%) patients had SCHCP. The median time to symptom development was 7 months (range, 1-48 months). The mean CALV was 334.0 {+-} 194.0 mm{sup 2} (range, 44.70-1170 mm{sup 2}). The intraclass correlation coefficient was 0.988 (95% confidence interval [CI], 0.976-0.994; p < 0.001). In multivariate analysis, the CALV had a significant relationship with the development of SCHCP (p < 0.001; odds ration [OR] = 1.005; 95% CI, 1.002-1.007). Tumor volume and female sex also had a significant association (p < 0.001; OR = 1.246; 95% CI, 1.103-1.409; p < 0.009; OR = 7.256; 95% CI, 1.656-31.797, respectively). However, age failed to show any relationship with the development of SCHCP (p = 0.364). Conclusion: Brain atrophy may be related to de novo SCHCP after SRS, especially in female patients with a large VS. Follow-up surveillance should be individualized, considering the risk factors involved for each patient, for prompt diagnosis of SCHCP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tumor Size on Abdominal MRI Versus Pathologic Specimen in Resected Pancreatic Adenocarcinoma: Implications for Radiation Treatment Planning

Purpose: We assessed the accuracy of abdominal magnetic resonance imaging (MRI) for determining tumor size by comparing the preoperative contrast-enhanced T1-weighted gradient echo (3-dimensional [3D] volumetric interpolated breath-hold [VIBE]) MRI tumor size with pathologic specimen size. Methods and Materials: The records of 92 patients who had both preoperative contrast-enhanced 3D VIBE MRI images and detailed pathologic specimen measurements were available for review. Primary tumor size from the MRI was independently measured by a single diagnostic radiologist (P.M.) who was blinded to the pathology reports. Pathologic tumor measurements from gross specimens were obtained from the pathology reports. The maximum dimensions of tumor measured in any plane on the MRI and the gross specimen were compared. The median difference between the pathology sample and the MRI measurements was calculated. A paired t test was conducted to test for differences between the MRI and pathology measurements. The Pearson correlation coefficient was used to measure the association of disparity between the MRI and pathology sizes with the pathology size. Disparities relative to pathology size were also examined and tested for significance using a 1-sample t test. Results: The median patient age was 64.5 years. The primary site was pancreatic head in 81 patients, body in 4, and tail in 7. Three patients were American Joint Commission on Cancer stage IA, 7 stage IB, 21 stage IIA, 58 stage IIB, and 3 stage III. The 3D VIBE MRI underestimated tumor size by a median difference of 4 mm (range, −34-22 mm). The median largest tumor dimensions on MRI and pathology specimen were 2.65 cm (range, 1.5-9.5 cm) and 3.2 cm (range, 1.3-10 cm), respectively. Conclusions: Contrast-enhanced 3D VIBE MRI underestimates tumor size by 4 mm when compared with pathologic specimen. Advanced abdominal MRI sequences warrant further investigation for radiation therapy planning in pancreatic adenocarcinoma before routine integration into the treatment planning process.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multivariate Normal Tissue Complication Probability Modeling of Heart Valve Dysfunction in Hodgkin Lymphoma Survivors

Purpose: To establish a multivariate normal tissue complication probability (NTCP) model for radiation-induced asymptomatic heart valvular defects (RVD). Methods and Materials: Fifty-six patients treated with sequential chemoradiation therapy for Hodgkin lymphoma (HL) were retrospectively reviewed for RVD events. Clinical information along with whole heart, cardiac chambers, and lung dose distribution parameters was collected, and the correlations to RVD were analyzed by means of Spearman's rank correlation coefficient (Rs). For the selection of the model order and parameters for NTCP modeling, a multivariate logistic regression method using resampling techniques (bootstrapping) was applied. Model performance was evaluated using the area under the receiver operating characteristic curve (AUC). Results: When we analyzed the whole heart, a 3-variable NTCP model including the maximum dose, whole heart volume, and lung volume was shown to be the optimal predictive model for RVD (Rs = 0.573, P<.001, AUC = 0.83). When we analyzed the cardiac chambers individually, for the left atrium and for the left ventricle, an NTCP model based on 3 variables including the percentage volume exceeding 30 Gy (V30), cardiac chamber volume, and lung volume was selected as the most predictive model (Rs = 0.539, P<.001, AUC = 0.83; and Rs = 0.557, P<.001, AUC = 0.82, respectively). The NTCP values increase as heart maximum dose or cardiac chambers V30 increase. They also increase with larger volumes of the heart or cardiac chambers and decrease when lung volume is larger. Conclusions: We propose logistic NTCP models for RVD considering not only heart irradiation dose but also the combined effects of lung and heart volumes. Our study establishes the statistical evidence of the indirect effect of lung size on radio-induced heart toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of 4-Dimensional Computed Tomography Ventilation With Nuclear Medicine Ventilation-Perfusion Imaging: A Clinical Validation Study

Purpose: Four-dimensional computed tomography (4DCT) ventilation imaging provides lung function information for lung cancer patients undergoing radiation therapy. Before 4DCT-ventilation can be implemented clinically it needs to be validated against an established imaging modality. The purpose of this work was to compare 4DCT-ventilation to nuclear medicine ventilation, using clinically relevant global metrics and radiologist observations. Methods and Materials: Fifteen lung cancer patients with 16 sets of 4DCT and nuclear medicine ventilation-perfusion (VQ) images were used for the study. The VQ-ventilation images were acquired in planar mode using Tc-99m-labeled diethylenetriamine-pentaacetic acid aerosol inhalation. 4DCT data, spatial registration, and a density-change-based model were used to compute a 4DCT-based ventilation map for each patient. The percent ventilation was calculated in each lung and each lung third for both the 4DCT and VQ-ventilation scans. A nuclear medicine radiologist assessed the VQ and 4DCT scans for the presence of ventilation defects. The VQ and 4DCT-based images were compared using regional percent ventilation and radiologist clinical observations. Results: Individual patient examples demonstrate good qualitative agreement between the 4DCT and VQ-ventilation scans. The correlation coefficients were 0.68 and 0.45, using the percent ventilation in each individual lung and lung third, respectively. Using radiologist-noted presence of ventilation defects and receiver operating characteristic analysis, the sensitivity, specificity, and accuracy of the 4DCT-ventilation were 90%, 64%, and 81%, respectively. Conclusions: The current work compared 4DCT with VQ-based ventilation using clinically relevant global metrics and radiologist observations. We found good agreement between the radiologist's assessment of the 4DCT and VQ-ventilation images as well as the percent ventilation in each lung. The agreement lessened when the data were analyzed on a regional level. Our study presents an important step for the integration of 4DCT-ventilation into thoracic clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prognostic Value and Reproducibility of Pretreatment CT Texture Features in Stage III Non-Small Cell Lung Cancer

Purpose: To determine whether pretreatment CT texture features can improve patient risk stratification beyond conventional prognostic factors (CPFs) in stage III non-small cell lung cancer (NSCLC). Methods and Materials: We retrospectively reviewed 91 cases with stage III NSCLC treated with definitive chemoradiation therapy. All patients underwent pretreatment diagnostic contrast enhanced computed tomography (CE-CT) followed by 4-dimensional CT (4D-CT) for treatment simulation. We used the average-CT and expiratory (T50-CT) images from the 4D-CT along with the CE-CT for texture extraction. Histogram, gradient, co-occurrence, gray tone difference, and filtration-based techniques were used for texture feature extraction. Penalized Cox regression implementing cross-validation was used for covariate selection and modeling. Models incorporating texture features from the 33 image types and CPFs were compared to those with models incorporating CPFs alone for overall survival (OS), local-regional control (LRC), and freedom from distant metastases (FFDM). Predictive Kaplan-Meier curves were generated using leave-one-out cross-validation. Patients were stratified based on whether their predicted outcome was above or below the median. Reproducibility of texture features was evaluated using test-retest scans from independent patients and quantified using concordance correlation coefficients (CCC). We compared models incorporating the reproducibility seen on test-retest scans to our original models and determined the classification reproducibility. Results: Models incorporating both texture features and CPFs demonstrated a significant improvement in risk stratification compared to models using CPFs alone for OS (P=.046), LRC (P=.01), and FFDM (P=.005). The average CCCs were 0.89, 0.91, and 0.67 for texture features extracted from the average-CT, T50-CT, and CE-CT, respectively. Incorporating reproducibility within our models yielded 80.4% (±3.7% SD), 78.3% (±4.0% SD), and 78.8% (±3.9% SD) classification reproducibility in terms of OS, LRC, and FFDM, respectively. Conclusions: Pretreatment tumor texture may provide prognostic information beyond that obtained from CPFs. Models incorporating feature reproducibility achieved classification rates of ∼80%. External validation would be required to establish texture as a prognostic factor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗