Search NASA⌕ Search

SEARCH · Search NASA

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

The faint limit of the Hubble Space Telescope faint object spectrograph and rejection of the cosmic-ray background

The faintest object which can be observed with the Hubble Space Telescope (HST) Faint Object Spectrograph (FOS) is set by the detector cosmic-ray background and not by object flux. We use data from Beaver and Lyons to show that 48% of the background counts are from cosmic rays which each generate a near instantaneous burst of two or more counts. Setting the FOS threshold parameter REJLIM = 1, which rejects all frames with more than one count increases the ratio of signal-to-dark counts (S/D) by a factor of 1.94, regardless of the frame time or the object signal, because half of the dark counts which arrive in single counts (from either cosmic-ray bursts or thermal dark current photoemission) are rejected at the same rate as the object signal. But the signal-to-noise ratio (SNR proportional to S/square root of S + D) increases by at most a factor of 1.35, and for realistic parameters and taking into account dead time, we expect a gain in SNR of only 1.18. If a diode has failed and now emits noise, no data at all will be recorded. The chance of this occurring is approximately = 10% , and for this reason we do not recommend the use of REJLIM. The two-point correlation function of dark counts per pixel has strong peaks every four pixels, caused by the action of quarter-stepping on the counts from large bursts. The counts from such bursts spread over at least 80-100 diodes, and we show that such bursts can be rejected during data reduction if the data are recorded in RAPID mode with individual exposures of about 35 seconds. The SNR of the spectrum can also be improved by weighting each exposure by its SNR (a function ofthe mean dark count rate at that time), since dark varies by a factor of 2 around an orbit. These two procedures together increase the SNR by a factor of 1.1.3 (a 28% gain in exposure time) in regions of a spectrum where the object is much fainter than the background. We find that the Ly-alpha and O I sky emission lines give at most 4 (counts/array/s/sq arcsec), and typically half this number. With a small frame time and a small entrance aperture, these counts cause REJLIM = 1 to reject only a few percent of the data. We discuss only the HST FOS blue side detector, but the same ideas apply to any photon counter which records bursts of noise, and the calculations resemble those for the loss of signal due to coincidences in photon counters. In the ideal photon counter the dark counts are readily distinguished from photons. One way to do this is to add detectors which records only dark current, so that every cosmic ray produces more than one count and the instrument can be operated in an anti-coincidence mode.

Tytler, David↗

Modeling the stellar contribution to the Galactic component of the diffuse soft X-ray background. I - Background fluxes and number counts

A combination of a stellar Galaxy model based on optical data, stellar X-ray luminosity functions derived from the full Einstein base, and a model for X-ray absorption derived from hydrogen column densities are used to estimate the contribution to the diffuse soft X-ray background flux from the main-sequence A, F, G, K, and M stars, and RS CVn stars, at various energies ranging from 0.1 to about 5 keV. Previous discrepancies between earlier estimates of the stellar contribution to the diffuse soft X-ray background are resolved; this stellar contribution to the diffuse soft X-ray background is found to be under 3 percent for photon energies less than energy I and J bands (about 0.8-2 keV), at a threshold sensitivity for point source detection about 10 exp -10 ergs/s sq cm. At low latitudes, stellar contribution estimates are less than 3 percent below 0.3 keV, 7-40 percent in the medium-energy bands, and 27-70 percent in the I and J bands. It is shown that while dM stars are the major contributors to the diffuse stellar flux, other stellar types contribute as much as 40 percent of this flux at the higher energies in the passband studied.

Kashyap, V.↗

BOREAS Landsat MSS Imagery: Digital Counts

The Boreal Ecosystem-Atmospheric Study (BOREAS) Staff Science Satellite Data Acquisition Program focused on providing the research teams with the remotely sensed satellite data products they needed to compare and spatially extend point results. The Earth Resources Technology Satellite (ERTS) Program launched the first of a series of satellites (ERTS-1) in 1972. Part of the NASA Earth Resources Survey Program, the ERTS Program and the ERTS satellites were later renamed Landsat to better represent the civil satellite program's prime emphasis on remote sensing of land resources. Landsat satellites 1 through 5 carry the Multispectral Scanner (MSS) sensor. Canada for Remote Sensing (CCRS) and BOREAS personnel gathered a set of MSS images of the BOREAS region from Landsat satellites 1, 2, 4, and 5 covering the dates of 21 Aug 1972 to 05 Sep 1988. The data are provided in binary image format files of various formats. The Landsat MSS imagery is available from the Earth Observing System Data and Information System (EOSDIS) Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC).

Hall, Forrest G.↗

Pulse shape discrimination of Cs 2 LiYCl 6 :Ce 3+ detectors at high count rate based on triangular and trapezoidal filters

Cs 2 LiYCl 6 :Ce 3+ (CLYC) detectors have demonstrated the capability to simultaneously detect γ-rays and thermal and fast neutrons with medium energy resolution, reasonable detection efficiency, and substantially high pulse shape discrimination performance. In this work, a disadvantage of CLYC detectors is the long scintillation decay times, which causes pulse pile-up at moderate input count rate. Pulse processing algorithms were developed based on triangular and trapezoidal filters to discriminate between neutrons and γ-rays at high count rate. The algorithms were first tested using low-rate data. They exhibit a pulse-shape discrimination performance comparable to that of the charge comparison method, at low rate. Then, they were evaluated at high count rate. Neutrons and γ-rays were adequately identified with high throughput at rates of up to 375 kcps. The algorithm developed using the triangular filter exhibits discrimination capability marginally higher than that of the trapezoidal filter based algorithm irrespective of low or high rate. The algorithms exhibit low computational complexity and are executable on an FPGA in real-time. Finally, they are also suitable for application to other radiation detectors whose pulses are piled-up at high rate owing to long scintillation decay times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A HYBRID MODEL FOR THE EVOLUTION OF GALAXIES AND ACTIVE GALACTIC NUCLEI IN THE INFRARED

We present a comprehensive investigation of the cosmological evolution of the luminosity function of galaxies and active galactic nuclei (AGNs) in the infrared (IR). Based on the observed dichotomy in the ages of stellar populations of early-type galaxies on one side and late-type galaxies on the other, the model interprets the epoch-dependent luminosity functions at z {>=} 1.5 using a physical approach for the evolution of proto-spheroidal galaxies and of the associated AGNs, while IR galaxies at z < 1.5 are interpreted as being mostly late-type ''cold'' (normal) and ''warm'' (starburst) galaxies. As for proto-spheroids, in addition to the epoch-dependent luminosity functions of stellar and AGN components separately, we have worked out, for the first time, the evolving luminosity functions of these objects as a whole (stellar plus AGN component), taking into account in a self-consistent way the variation with galactic age of the global spectral energy distribution. The model provides a physical explanation for the observed positive evolution of both galaxies and AGNs up to z {approx_equal} 2.5 and for the negative evolution at higher redshifts, for the sharp transition from Euclidean to extremely steep counts at (sub-)millimeter wavelengths, as well as the (sub-)millimeter counts of strongly lensed galaxies that are hard to account for by alternative, physical or phenomenological, approaches. The evolution of late-type galaxies and z < 1.5 AGNs is described using a parametric phenomenological approach. The modeled AGN contributions to the counts and to the cosmic infrared background (CIB) are always sub-dominant. They are maximal at mid-IR wavelengths: the contribution to the 15 and 24 {mu}m counts reaches 20% above 10 and 2 mJy, respectively, while the contributions to the CIB are of 8.6% and of 8.1% at 15 {mu}m and 24 {mu}m, respectively. The model provides a good fit to the multi-wavelength (from the mid-IR to millimeter waves) data on luminosity functions at different redshifts and on number counts (both global and per redshift slices). A prediction of the present model, useful to test it, is a systematic variation with wavelength of the populations dominating the counts and the contributions to the CIB intensity. This implies a specific trend for cross-wavelength CIB power spectra, which is found to be in good agreement with the data.

79 ASTRONOMY AND ASTROPHYSICS↗

Verification Data Pattern Recognition and Change Detection at the Neutron Instrument Level

As the pressure on International Atomic Energy Agency (IAEA) safeguards resources increases, there is a drive to essentially “do more with less.” New ways of using current verification instrumentation and visualizing the collected data are needed, coupled with maintaining and sustaining the current safeguards instrumentation fleet. This paper explores how to innovate with current safeguards neutron instrumentation using data-driven algorithms at the instrument level. A concept is described for upgrading current neutron counting systems with modern electronics by leveraging electronics developments in other fields (e.g., high-energy physics) to facilitate full list mode data acquisition and, therefore, expand existing analyses to pattern recognition and change detection at the instrument level. The aim is to advance correlated neutron counting by improving the reliability of detecting nuclear material diversion and, at the same time, to improve the sustainability of those systems. It is likely that upgrading existing systems with new hardware and software is more cost-effective than replacing systems with other novel systems that might meet this need. A specific project example is highlighted in which a system was upgraded by retrofitting the standard uranium neutron collar detector with new electronics; as a result, verification data can be analyzed in new ways. A new neutron analysis method, the “List Mode Response Matrix,” has been developed to analyze every pulse train from the detector array and thus enable the verification of spatial information about the assay item for safeguards inspections. This project has improved the reliability of resolving individual fuel pin locations within a given fresh fuel assembly and the percentage of partial defects detected. Herein, the overall concept of upgrading current neutron counting systems is discussed with respect to the potential increase in analysis capabilities. In addition, the details and results of the list mode collar project are discussed.

Worrall, Louise G.↗

An experimental comparison of triggered and random pulse train uncertainties

In this paper we present an experimental comparison of signal-triggered and randomly triggered based analysis algorithms of neutron multiplicity data. Traditional shift register type signal-triggered multiplicity analysis of singles, doubles and triples rates is compared with analysis using randomly triggered gates. Two methods of random gate generation are explored - non-overlapping gates (Feyrunan approach) and periodic overlapping gates (fast accidentals). Using californium sources with low, medium and high rate in combination with AmLi sources (as a surrogate for plutonium) we investigate relative standard deviation (RSD) of data in order to determine if there are parameter spaces in which one of the measurement methods should be preferred. Neutron correlation analysis is a commonly used NDA technique to assay plutonium mass. The data can be collected in two distinct ways: using signal-triggered or randomly triggered counting gates. Analysis algorithms were developed for both approaches to determine singles (S), doubles (D) and triples (7) rates from the measured sample. Currently the most commonly implemented technique to collect neutron coincidence data utilizes shift register based electronics. Shift register uses signal-triggered counting gates to generate foreground multiplicity distribution of correlated+accidental events and a random gate (opened after a predefined long delay following the signal trigger) to generate background multiplicity distribution of accidental events. Modern shift registers include fast accidental option to sample data with a fixed clock frequency. This way a set of overlapping gates is used to generate background multiplicity distributions in order to improve the measurement precision. In parallel to shift register approach the Feynman variance technique is frequently used, which utilizes set of consecutive non-overlapping gates. In general, different user communities (e.g. safeguards, nuclear material accountancy, emergency response) have used only one of the two analysis methods for the nuclear material assay. The aim of this study is to provide a systematic comparison of the precision of the measured S, D, T rates and {sup 240}Pu effective mass obtained using the above mentioned pulse train sampling techniques. In order to perform this task, a LANL developed list mode based data acquisition system is used, where the entire pulse train is recorded and subsequently analyzed. The list mode acquisition brings an essential advantage for this type of comparison, since the very same pulse train can be analyzed using signal-triggered as well as randomly triggered counting gates. The aim of this study is not only to compare the precision of signal-triggered versus random triggered sampling techniques, but also to investigate the influence of fast accidental sampling on the precision of signal-triggered results. In addition the different random sampling techniques used in safeguards are investigated. For this purpose we implement two types of random sampling - non-overlapping gates (Feynrnan approach) and periodic overlapping gates (fast accidentals). In the following sections the equations utilized in the pulse train analysis are described, experimental setup and measurement techniques are discussed and finally the results are summarized and discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CNO Processing in Massive Algol Binaries

This program, used ultraviolet observations by the IUE Observatory along with other tools to search for abundance anomalies indicative of CNO processing in the secondary (mass-donating) stars of six interacting binary systems. Related IUE-based activities were also undertaken under this grant. Two Supplements to the grant were awarded. Supplement No. 1 was in connection with the NASA Grant Supplements for Education program, for a workshop for elementary school science teachers. The two sessions of the workshop were held October 24 and November 14, 1992. Eighteen school teachers from central Pennsylvania, grades 1-7, participated in the workshop, for which they received one unit of in-service training credit from their Intermediate Unit. Supplement No. 2 was awarded for additional IUE observations of the Algol stars V342 Aql and TU Mon. Observations of all six candidate stars were made with IUE, and attention was narrowed to TU Mon in particular, for which further IUE observations were made using Director's discretionary time. Observations of TU Mon were also carried out with the Voyager UV spectrometers, and optical spectroscopy was obtained on several occasions at Penn State's Black Moshannon Observatory. Photometric data on TU Mon were acquired by Dr. Paul Etzel at Mt. Laguna Observatory (MLO). McGouldrick was employed part-time during the Fall academic semester to assist in accessing the IUE Archive, and to correlate data on some cataclysmic variables and related objects that were observed with both IUE and the Voyager Far Ultraviolet Spectrometers. Approximately 21 relevant binary systems were observed with the Voyager UVS over the past decade, and a paper is being prepared for eventual publication that will serve as an index to the UVS data archive on these stars, providing observation dates, mean count rates in far and extreme UV bands, and a discussion of the relevant literature concerning the far UV behavior (including correlative IUE information from the archive and the literature). Much of the activity under the grant was in connection with V342 Aquilae, a 3.39 day Algol system thought to be in a state of rapid mass transfer. The goal was to combine optical and ultraviolet data to arrive at a robust, informative interpretation of this unique binary system. Complete orbital phase coverage of V342 Aql was obtained spectroscopically and photometrically.

Wade, Richard A.↗

The minimum crystal size needed for a complete diffraction data set

A formula for absolute scattering power is derived to include spot fading arising from radiation damage and the crystal volume needed to collect diffraction data to a given resolution is calculated. In this work, classic intensity formulae were united with an empirical spot-fading model in order to calculate the diameter of a spherical crystal that will scatter the required number of photons per spot at a desired resolution over the radiation-damage-limited lifetime. The influences of molecular weight, solvent content, Wilson B factor, X-ray wavelength and attenuation on scattering power and dose were all included. Taking the net photon count in a spot as the only source of noise, a complete data set with a signal-to-noise ratio of 2 at 2 Å resolution was predicted to be attainable from a perfect lysozyme crystal sphere 1.2 µm in diameter and two different models of photoelectron escape reduced this to 0.5 or 0.34 µm. These represent 15-fold to 700-fold less scattering power than the smallest experimentally determined crystal size to date, but the gap was shown to be consistent with the background scattering level of the relevant experiment. These results suggest that reduction of background photons and diffraction spot size on the detector are the principal paths to improving crystallographic data quality beyond current limits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparisons of the dimensionality and features of simulated Landsat-4 MSS and TM data

The spectral characteristics of the Landsat-4 MSS and TM are compared using signal counts simulated from field-measured reflectance spectra. The Dave atmospheric model and prelaunch sensor characteristics are also used in the simulation. Comparison is made based on individual bands and Tasseled Cap transformed data. TM bands 2, 3, and 4 are shown to contain virtually all the information contained in the four MSS bands. Tasseled Cap transformed data from the six reflective bands of the TM are shown to contain at least one and possibly two additional dimensions of information beyond the two dimensions in MSS data, while still providing a direct association with the MSS Tasseled Cap features.

Crist, E. P.↗

Energetic charged particles in the Uranian magnetosphere

The cosmic ray instrument on Voyager 2 obtained detailed charged particle data on the path the spacecraft followed through the newly-discovered Uranian magnetosphere. Notably, the electron counts did not rise above background until the spacecraft was deep in the magnetosphere. The data further indicated that the satellites Miranda, Ubriel and Ariel impose a sweep effect on MeV electrons, which move radially inward from some source in the outer magnetosphere or the magnetotail. The energetic particle data also supported a firm pitch angle dependence for proton energy spectra in the 1-8 MeV range. Finally, the particle density data were commensurate with a dipole magnetic field tilted 60.1 deg in relation to the planet and rotating every 17.4 hr, close to estimates from other instruments.

Stone, E. C.↗

Impact Factors for Microinvasion in Patients With Hepatocellular Carcinoma: Possible Application to the Definition of Clinical Tumor Volume

Purpose: To evaluate the degree of invasion of hepatocellular carcinoma (HCC) microscopically that will provide a potential application for gross tumor volume to clinical tumor volume (GTV-to-CTV) expansion. Methods and Materials: From January 2002 to January 2006, 149 HCC patients were selected from those who had undergone surgical resection. Pathology slides and clinical data of all patients were reviewed, including platelet counts, serum alpha-fetoprotein (AFP) levels, degree of liver cirrhosis, tumor size, capsular status, portal vein invasion, TNM stage, and histologic tumor grade. The distance between the tumor margin (or fibrous capsule) and the invasive lesions was measured by senior pathologists. Results: Of these 149 patients, 79 (53.0%) patients presented with tumor microinvasion between 0.5 and 4 mm. This degree of microinvasion was inversely correlated with lower platelet counts and positively correlated with higher AFP levels, larger tumor sizes, portal vein invasion, and advanced TNM stage. Microinvasion distances less than or equal to 2 mm were found in 96.1% of patients (74/77) with tumor dimensions less than or equal to 5 cm and in 94.5% of patients (85/90) with AFP levels less than 400 mug/l. Conclusions: Based on our study findings, GTV-to-CTV expansions of 4 mm for HCC are required to conceal the gross tumor and any microscopic disease with 100% accuracy. Tumor size and AFP levels are the simplest indicators for determining the GTV-to-CTV distance for HCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transport study of intense-laser-produced fast electrons in solid targets with a preplasma created by a long pulse laser

The effect of preplasma on fast electron generation and transport has been studied using an intense-laser pulse (I=2x10{sup 18} W/cm{sup 2}) at the Osaka University. An external long pulse laser beam (E<1.5 J) was used to create various levels of preplasmas in front of a planar target for a systematic study. Kalpha x-ray emission from a fluorescence layer (copper) was absolutely counted and its spatial distribution was monitored. Experimental data show Kalpha x-ray signal reduction (up to 60%) with an increase in the preplasma level. In addition, a ring structure of Kalpha x rays was observed with a large preplasma. The underlying physics of the ring structure production was studied by integrating the modeling using a radiation hydrodynamics code and a hybrid particle-in-cell code. Modeling shows that the ring structure is due to the thermoelectric magnetic field excited by the long pulse laser irradiation and an electrostatic field due to the fast electrons in the preplasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A NEW STATISTIC FOR ANALYZING BARYON ACOUSTIC OSCILLATIONS

We introduce a new statistic {omega}{sub l}(r{sub s}) for measuring and analyzing large-scale structure and particularly the baryon acoustic oscillations. {omega}{sub l}(r{sub s}) is a band-filtered, configuration space statistic that is easily implemented and has advantages over the traditional power spectrum and correlation function estimators. Unlike these estimators, {omega}{sub l}(r{sub s}) can localize most of the acoustic information into a single dip at the acoustic scale while avoiding sensitivity to the poorly constrained large-scale power (i.e., the integral constraint) through the use of a localized and compensated filter. It is also sensitive to anisotropic clustering through pair counting and does not require any binning of data. We measure the shift in the acoustic peak due to nonlinear effects using the monopole {omega}{sub 0}(r{sub s}) derived from subsampled dark matter (DM) catalogs as well as from mock galaxy catalogs created via halo occupation distribution modeling. All of these are drawn from 44 realizations of 1024{sup 3} particle DM simulations in a 1 h {sup -1} Gpc box at z = 1. We compare these shifts with those obtained from the power spectrum and conclude that the results agree. We therefore expect that distance measurements obtained from {omega}{sub 0}(r{sub s}) and P(k) will be consistent with each other. We also show that it is possible to extract the same amount of acoustic information by fitting over a finite range using either {omega}{sub 0}(r{sub s}) or P(k) derived from equal volume surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

SOFT CORONAL X-RAYS FROM {beta} PICTORIS

A-type stars are expected to be X-ray dark, yet weak emission has been detected from several objects in this class. We present new Chandra/HRC-I observations of the A5 V star {beta} Pictoris. It is clearly detected with a flux of (9 {+-} 2) Multiplication-Sign 10{sup -4} counts s{sup -1}. In comparison with previous data this constrains the emission mechanism and we find that the most likely explanation is an optically thin, collisionally dominated, thermal emission component with a temperature around 1.1 MK. We interpret this component as a very cool and dim corona, with log L{sub X} /L{sub bol} = -8.2 (0.2-2.0 keV). Thus, it seems that {beta} Pictoris shares more characteristics with cool stars than previously thought.

79 ASTRONOMY AND ASTROPHYSICS↗

Real-time online monitoring of radwaste storage: A proof-of-principle test prototype

A prototype array of modular sensors for online monitoring of radioactive waste was developed at INFN-LNS. We implemented a new kind of gamma mini-sensor, based on Silicon Photomultipliers and scintillating fibers, that behaves like a cheap scintillating Geiger-Muller counter. It can be placed in shape of a fine grid around each single waste drum in a repository. After simulating the counting response of thin scintillating fibers to gamma radiation, we verified our simulation results with measurements using radioactive sources. Front-end electronics and an FPGA-based counting system were developed to handle the field data, also implementing data transmission, a graphical user interface and a data storage system. A test of four sensors in a real radwaste storage site was performed with promising results. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗