Search NASA⌕ Search

SEARCH · Search NASA

Results for “data intensive computing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Raptor

Raptor is an efficient Python-based tool for predicting the formation and morphology of stochastic lack of fusion defects in metal AM processes. A major obstacle for the qualification and certification of additively manufactured parts in critical applications continues to be performance variability caused in part by porosity-related defects. High-fidelity process models that could predict these defect features are currently too computationally expensive for component-level analysis. To address this, Raptor employs a high-performance geometric method to model the dynamic melt pool rather than relying on computationally intensive thermal fluid dynamics. This allows Raptor to rapidly identify regions of unmelted material that correspond to lack of fusion pores. The efficiency of this approach significantly reduces the time and resources needed for generating 3D defect predictions, which enables users to conduct large-scale parameter studies and evaluate how process variations affect part quality. The framework offers operational flexibility; users can execute simulations through a simple command line interface or integrate core functions as a library within larger computational workflows. Simulation outputs include 3D porosity maps for visualization and tools for quantitative morphological analysis. These results are suitable for direct comparison with experimental characterization data from methods such as X-ray computed tomography and can be used for statistical process optimization.

Subraveti, Vamsi [Vanderbilt Univ., Nashville, TN ↗

Automated Assembly Progress Monitoring in Modular Construction Factories Using Computer Vision-Based Instance Segmentation

Modular construction has recently gained interest as a transformative construction method. In this method, a large portion of the construction is performed inside factories, where processes are fast-paced and interdependent; therefore, any deviation from the schedule can delay the production. Such deviations are frequent in modular factories due to the labor-intensive nature of the tasks. This propagation of delays can be mitigated by continuously monitoring each process; however, current manual monitoring methods are laborious, and recently proposed contact sensor-based methods are intrusive to the work. In addition, recent computer vision-based monitoring methods inside factories are limited to detection algorithms that fail to provide the pixel-level accuracy required for assembly progress monitoring in highly occluded factory scenes, and they require a large number of manual annotations. Therefore, this paper proposes a method to monitor the installation of subassemblies in modular construction factories using mask R-CNN instance segmentation and improves the data efficiency of the model using a copy-paste augmentation method. This method was validated on the CCTV videos captured from a modular construction factory in the US, resulting in a 9% mAP improvement in segmentation.

computer vision↗

Inversion of dynamical Bragg intensities to complex structure factors by iterated projections. For Ultramic. 2020. ("Pico" Festschrift, May 2021)

We discuss a method for recovering complex structure factors from many simultaneously excited Bragg beam intensities is described. The method is applied to simulated transmission electron diffraction data over a wide range of crystal thickness and beam energies. The method is based on iterated projections between structure and scattering matrices, which are related by a matrix unitary transformation, exponential, which we invert. The algorithm removes multiple-scattering perturbations from diffraction data and might be extended to other fields, including X-ray and neutron diffraction and cryo-electron microscopy. Because coherent multiple scattering involves interference between Bragg beams, the method also solves the phase problem. Unlike dynamical inversion from electron microscope images or ptychography data, the method, which starts with Bragg beam intensities, provides complex structure factors unaffected by focusing errors or resolution limitations imposed by lenses. We provide inversions from simulated data with 441 simultaneously excited Bragg beams over a range of thickness and beam energy. We discuss the retrieval of chirality information from enantiomorphs, the efficient incorporation of symmetry information using the irreducible representation of the group of structure matrices, and the effect of HOLZ lines to provide three-dimensional information.

97 MATHEMATICS AND COMPUTING↗

Baltimore Social-Environmental Collaborative (BSEC) Doppler Lidar & Derived Products

This repository contains all processed Doppler‐lidar outputs from the PSU lidar deployed for the Baltimore Social‐Environmental Collaborative (BSEC) project. Vertical Stare Scans (fixed‐beam, vertical profiling): 1 Hz backscatter intensity (m⁻¹ sr⁻¹), signal‐to‐noise ratio (unitless), and Doppler vertical‐velocity (m s⁻¹) on ~30 m range gates, stored as CF-compliant NetCDF. Wind Profiles (horizontal‐wind retrieval): daily NetCDF outputs of retrieved horizontal wind speed (m s⁻¹) and direction (degrees), computed from the angled‐scan returns. Profile Statistics (summary statistics on the vertical velocity): 15 min windows (default) of mean, variance, skewness, kurtosis, high-frequency variance, etc., as a function of height; saved as CF-compliant NetCDF files. Boundary Layer Height (BLH) (fuzzy-logic output): 15 min BLH estimates (m), with lower/upper fuzzy bounds (m) and a quality flag (0–4) indicating data status (e.g., no data, good, below range, ran out of signal, cloud-topped). Cloud Base Height (Haar-gradient detection): 15 min estimates of cloud-base height (m) with a cloud-detection quality flag (0–3: none, low, moderate, high). All five product streams are organized by year and date under their own top-level folders (01_Vertical_Stare_Scans/ through 05_Cloud_Height/). Each folder contains a data_ /YYYY/ subdirectory with daily CF-compliant NetCDF outputs (96 windows per day at 15 min intervals). Global attributes in each file include creation history, version (2.0.0), institution, and source. Instrument & MeasurementsThe PSU Doppler Lidar samples aerosol backscatter (m⁻¹ sr⁻¹), signal-to-noise ratio, and radial velocity at ~1 Hz. Vertical stare scans point the beam straight up; after collecting angled scans through multiple elevation angles, the "Wind Profiles" product contains the fully retrieved horizontal wind speed and direction. Data were collected continuously at ~30 m range resolution, with a typical height ceiling of ~12 km. How to Use Open any NetCDF with Python's xarray, MATLAB, or similar CF-compliant tools. Stare scans and angled-scan retrievals (Wind Profiles) are CF-compliant daily NetCDF files. Profile-Statistics, BLH, and Cloud Height files are daily 15 min summaries (96 time steps per file). Inspect the included variables (e.g., vertical_velocity_variance, wind_speed, BLH, cloud_base_height) for your analyses. Use the quality flags (BLH_flag, cloud_flag) to filter out poor-quality retrievals. For more information or questions about processing methods, please contact:Nicholas E. Prince ⟨nec5299@psu.edu⟩Penn State Department of Meteorology & Atmospheric Science

Air Quality↗

SCinet Architecture: Featured at the International Conference for High Performance Computing,Networking, Storage and Analysis 2016

SCinet is the purpose-built network that operates during the International Conference for High Performance Computing,Networking, Storage and Analysis (Super Computing or SC). Created each year for the conference, SCinet brings to life a high-capacity network that supports applications and experiments that are a hallmark of the SC conference. The network links the convention center to research and commercial networks around the world. This resource serves as a platform for exhibitors to demonstrate the advanced computing resources of their home institutions and elsewhere by supporting a wide variety of applications. Volunteers from academia, government and industry work together to design and deliver the SCinet infrastructure. Industry vendors and carriers donate millions of dollars in equipment and services needed to build and support the local and wide area networks. Planning begins more than a year in advance of each SC conference and culminates in a high intensity installation in the days leading up to the conference. The SCinet architecture for SC16 illustrates a dramatic increase in participation from the vendor community, particularly those that focus on network equipment. Software-Defined Networking (SDN) and Data Center Networking (DCN) are present in nearly all aspects of the design.

Lyonnais, Marc↗

ASC Data Science Infrastructure Project June 2023 [Slides]

Data Science Infrastructure (DSI) Project offers a standardized but flexible way of storing data and associated metadata to support AI/ML and data intensive scientific workflows: Establish requirements via use case interviews; Develop DSI framework to support flexible, secure, and accessible data stores tailored to researcher needs; Augment existing institutional frameworks for code management, performance testing and file indexing via automated DSI interfaces; Deploy DSI framework to support key use cases in collaboration with domain scientists.

97 MATHEMATICS AND COMPUTING↗

PREDICTING CORONAL MASS EJECTIONS USING MACHINE LEARNING METHODS

Of all the activity observed on the Sun, two of the most energetic events are flares and coronal mass ejections (CMEs). Usually, solar active regions that produce large flares will also produce a CME, but this is not always true. Despite advances in numerical modeling, it is still unclear which circumstances will produce a CME. Therefore, it is worthwhile to empirically determine which features distinguish flares associated with CMEs from flares that are not. At this time, no extensive study has used physically meaningful features of active regions to distinguish between these two populations. As such, we attempt to do so by using features derived from (1) photospheric vector magnetic field data taken by the Solar Dynamics Observatory ’s Helioseismic and Magnetic Imager instrument and (2) X-ray flux data from the Geostationary Operational Environmental Satellite’s X-ray Flux instrument. We build a catalog of active regions that either produced both a flare and a CME (the positive class) or simply a flare (the negative class). We then use machine-learning algorithms to (1) determine which features distinguish these two populations, and (2) forecast whether an active region that produces an M- or X-class flare will also produce a CME. We compute the True Skill Statistic, a forecast verification metric, and find that it is a relatively high value of ∼0.8 ± 0.2. We conclude that a combination of six parameters, which are all intensive in nature, will capture most of the relevant information contained in the photospheric magnetic field.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparative Analysis of Intra-arterial Cone-Beam Versus Conventional Computed Tomography During Hepatic Arteriography for Transarterial Chemoembolization Planning

Purpose: To compare the imaging characteristics of intra-arterial cone-beam computed tomography during hepatic arteriography (CBCTHA) versus intra-arterial computed tomography during hepatic arteriography (CTHA) for intraprocedural transarterial chemoembolization (TACE) planning. Materials and Methods: This single-institution retrospective study included 144 patients (96 men, mean age 67.9 years; 48 women, mean age 62.3 years) who underwent 181 TACE sessions between January 2015 and July 2017. Intraprocedural CBCTHA (111 procedures) or CTHA (70 procedures) was performed for TACE planning. Reformatted maximum intensity projection CBCTHA and CTHA images were reviewed by two radiologists and classified using an ordinal scoring system (for tumor identification, tumor feeder vessel identification, and streaking artifact) and a binary scoring system (for the presence of breathing motion artifact and field of view encompassing the entire liver). Data were analyzed using an F test and a z-score test. Results: There were no significant differences in demographic and tumor characteristics between the CBCTHA and CTHA patient cohorts. CTHA was superior to CBCTHA for tumor identification (P < .0001), tumor feeder vessel identification (P < .05), streaking artifact (P < .0001), and field of view encompassing the entire liver (P < .0001). There was a trend toward a lower frequency of breathing motion artifact with CTHA than with CBCTHA (1.4% vs. 10%; P = .057). Conclusion: CTHA provides improved clinical relevant imaging information compared to CBCTHA for intraprocedural TACE planning. Level of Evidence: Level III, retrospective comparative study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric influences of rotational setup errors on head and neck carcinoma intensity-modulated radiation therapy treatments

The purpose of this work is to investigate the dosimetric influence of the residual rotational setup errors on head and neck carcinoma (HNC) intensity-modulated radiation therapy (IMRT) with routine 3 translational setup corrections and the adequacy of this routine correction. A total of 66 kV cone beam computed tomography (CBCT) image sets were acquired on the first day of treatment and weekly thereafter for 10 patients with HNC and were registered with the corresponding planning CT images, using 2 3-dimensional (3D) rigid registration methods. Method 1 determines the translational setup errors only, and method 2 determines 6-degree (6D) setup errors, i.e., both rotational and translational setup errors. The 6D setup errors determined by method 2 were simulated in the treatment planning system and were then corrected using the corresponding translational data determined by method 1. For each patient, dose distributions for 6 to 7 fractions with various setup uncertainties were generated, and a plan sum was created to determine the total dose distribution through an entire course and was compared with the original treatment plan. The average rotational setup errors were 0.7°± 1.0°, 0.1°±1.9°, and 0.3°±0.7° around left-right (LR), anterior-posterior (AP), and superior-inferior (SI) axes, respectively. With translational corrections determined by method 1 alone, the dose deviation could be large from fraction to fraction. For a certain fraction, the decrease in prescription dose coverage (V{sub p}) and the dose that covers 95% of target volume (D{sub 95}) could be up to 15.8% and 13.2% for planning target volume (PTV), and the decrease in V{sub p} and the dose that covers 98% of target volume (D{sub 98}) could be up to 9.8% and 5.5% for the clinical target volume (CTV). However, for the entire treatment course, for PTV, the plan sum showed that the average V{sub p} was decreased by 4.2% and D{sub 95} was decreased by 1.2 Gy for the first phase of IMRT with a prescription dose of 50 Gy. For CTV, the plan sum showed that the average V{sub p} was decreased by 0.8% and D{sub 98}, relative to prescription dose, was not decreased. Among these 10 patients, the plan sum showed that the dose to 1-cm{sup 3} spinal cord (D{sub 1cm{sup 3}}) increased no more than 1 Gy for 7 patients and more than 2 Gy for 2 patients. The average increase in D{sub 1cm{sup 3}} was 1.2 Gy. The study shows that, with translational setup error correction, the overall CTV V{sub p} has a minor decrease with a 5-mm margin from CTV to PTV. For the spinal cord, a noticeable dose increase was observed for some patients. So to decide whether the routine clinical translational setup error correction is adequate for this HNC IMRT technique, the dosimetric influence of rotational setup errors should be evaluated carefully from case to case when organs at risk are in close proximity to the target.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multireference Equation-of-Motion Driven Similarity Renormalization Group: Theoretical Foundations and Applications to Ionized States

We present a formulation and implementation of an equation-of-motion (EOM) extension of the multireference driven similarity renormalization group (MR-DSRG) formalism for ionization potentials (IP-EOM-DSRG). The IP-EOM-DSRG formalism results in a Hermitian generalized eigenvalue problem, delivering accurate ionization potentials for strongly correlated systems. The EOM step scales as O(N 5 ) with the basis set size N, allowing for efficient calculation of spectroscopic properties, such as transition energies and intensities. The IP-EOM-DSRG formalism is combined with three truncation schemes of the parent MR-DSRG theory: an iterative nonperturbative method with up to two-body excitations [MR-LDSRG(2)] and second- and third-order perturbative approximations [DSRG-MRPT2/3]. We benchmark these variants by computing (1) the vertical valence ionization potentials of a series of small molecules at both equilibrium and stretched geometries; (2) the spectroscopic constants of several low-lying electronic states of the OH, CN, N 2 + , and CO + radicals; and (3) the binding curves of low-lying electronic states of the CN radical. A comparison with experimental data and theoretical results shows that all three IP-EOM-DSRG methods accurately reproduce the vertical ionization potentials and spectroscopic constants of these systems. Notably, the DSRG-MRPT3 and MR-LDSRG(2) versions outperform several state-of-the-art multireference methods of comparable or higher cost.

Hamiltonians↗

BraggNet: integrating Bragg peaks using neural networks

Neutron crystallography offers enormous potential to complement structures from X-ray crystallography by clarifying the positions of low-Z elements, namely hydrogen. Macromolecular neutron crystallography, however, remains limited, in part owing to the challenge of integrating peak shapes from pulsed-source experiments. To advance existing software, this article demonstrates the use of machine learning to refine peak locations, predict peak shapes and yield more accurate integrated intensities when applied to whole data sets from a protein crystal. The artificial neural network, based on the U-Net architecture commonly used for image segmentation, is trained using about 100 000 simulated training peaks derived from strong peaks. After 100 training epochs (a round of training over the whole data set broken into smaller batches), training converges and achieves a Dice coefficient of around 65%, in contrast to just 15% for negative control data sets. Integrating whole peak sets using the neural network yields improved intensity statistics compared with other integration methods, including k-nearest neighbours. These results demonstrate, for the first time, that neural networks can learn peak shapes and be used to integrate Bragg peaks. In conclusion, it is expected that integration using neural networks can be further developed to increase the quality of neutron, electron and X-ray crystallography data.

97 MATHEMATICS AND COMPUTING↗

Shedding light on U.S. small and midsize data centers: Exploring insights from the CBECS survey

As demand for digital services accelerates, the energy and environmental footprint of data centers faces increasing scrutiny. While hyperscale cloud facilities have driven efficiency gains, small and midsize U.S. data centers remain a critical yet underexamined segment with significant untapped potential for energy savings. This study leverages data from the Commercial Buildings Energy Consumption Survey (CBECS) to analyze trends in server stocks, computing customers, cooling system adoption and efficiency, and geospatial distribution from 2012 to 2018. Findings reveal a sharp decline in small and midsize data centers, from 1.764 million to 1.398 million, with server counts dropping from 5.177 million to 4.262 million—aligning with the broader shift toward cloud computing. More than 40 % of servers in small data centers and 55 % in midsize data centers are housed in office buildings, and over half of all servers are concentrated in climate zones 5A (cold), 3A (mixed-humid), and 4A (mixed-humid), with the highest densities in metropolitan hubs. While direct expansion units remain the dominant cooling system, a clear transition toward more energy-efficient solutions, particularly air economizers, is evident. By integrating server and cooling system distributions, we estimate Power Usage Effectiveness (PUE) and Water Usage Effectiveness (WUE) for U.S. data centers by size and year. Results show that midsize data centers are more energy-efficient but more water-intensive due to the widespread use of water-cooled chillers. These findings highlight the trade-offs in cooling system selection and provide a critical foundation for policies aimed at enhancing efficiency in an evolving data center landscape.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The impacts of dental filling materials on RapidArc treatment planning and dose delivery: Challenges and solution

Purpose: The presence of high-density material in the oral cavity creates dose perturbation in both downstream and upstream directions at the surfaces of dental filling materials (DFM). In this study, the authors have investigated the effect of DFM on head and neck RapidArc treatment plans and delivery. Solutions are proposed to address (1) the issue of downstream dose perturbation, which might cause target under dosage, and (2) to reduce the upstream dose from DFM which may be the primary source of mucositis. In addition, an investigation of the clinical role of a custom-made plastic dental mold/gutter (PDM) in sparing the oral mucosa and tongue reaction is outlined.Methods: The influence of the dental filling artifacts on dose distribution was investigated using a geometrically well-defined head and neck intensity modulated radiation therapy (IMRT) verification phantom (PTW, Freiberg, Germany) with DFM inserts called amalgam, which contained 50% mercury, 25% silver, 14% tin, 8% copper, and 3% other trace metals. Three RapidArc plans were generated in the Varian Eclipse System to treat the oral cavity using the same computer tomography (CT) dataset, including (1) a raw CT image, (2) a streaking artifacts region, which was replaced with a mask of 10 HU, and (3) a 2 cm-thick 6000 HU virtual filter [a volume created in treatment planning system to compensate for beam attenuation, where the thickness of this virtual filter is based on the measured percent depth dose (PDD) data and Eclipse calculation]. The dose delivery for the three plans was verified using Gafchromic-EBT2 film measurements. The custom-made PDM technique to reduce backscatter dose was clinically tested on four head and neck cancer patients (T3, N1, M0) with DFM, two patients with PDM and the other two patients without PDM. The thickness calculation of the PDM toward the mucosa and tongue was purely based on the measured upstream dose. Patients’ with oral mucosal reaction was clinically examined initially and weekly during the course of radiotherapy.Results: For a RapidArc treatment technique, the backscatter dose from the DFM insert was measured to be 9.25 ± 2.17 in the IMRT-verification-phantom. The measured backscatter upstream dose from DFM for a single-field was 22% higher than without the DFM, whereas the downstream dose was lower by 14%. The values of homogeneity index for the plans with and without the application of mask were 0.09 and 0.14, respectively. The calculated mean treatment planning volume (PTV) dose differed from the delivered dose by 13% and was reduced to 2% when using the mask and virtual filter together. A grade 3 mucosa reaction was observed in the control group after 22–24 fractions (44–48 Gy). In contrast, no grade 3 mucositis was observed in the patients wearing the PDM after 25–26 fractions (50–52 Gy).Conclusions: The backscatter from the DFM for a single, parallel-opposed fields, and RapidArc treatment technique was found significant. The application of mask in replacing streaking artifacts can be useful in improving dose homogeneity in the PTV. The use of a virtual filter around the teeth during the planning phase reduces the target underdosage issue in the phantom. Furthermore, a reduction in mucositis is observed in the head and neck patients with the use of PDM.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fire Intensity Data for Validation of the Radiative Transfer Equation

A set of experiments and test data are outlined in this report that provides radiation intensity data for the validation of models for the radiative transfer equation. The experiments were performed with lightly-sooting liquid hydrocarbon fuels that yielded fully turbulent fires 2 m diameter). In addition, supplemental measurements of air flow and temperature, fuel temperature and burn rate, and flame surface emissive power, wall heat, and flame height and width provide a complete set of boundary condition data needed for validation of models used in fire simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

From Chaos to Clarity: Autonomous Materials Discovery for Extreme Environments [Slides]

The pursuit of advanced functional materials for energy applications demands an understanding of their behavior under the most challenging conditions. Extreme environments, characterized by intense radiation, high temperatures, and corrosive chemistries, push materials to their limits, often revealing unexpected behaviors and degradation pathways. Traditional materials research approaches, relying on trial-and-error experimentation, are often slow and resource-intensive, ill-suited to the complexities of extreme environments. This talk will explore the transformative potential of autonomous materials science in revolutionizing our understanding of materials synthesis and degradation in extreme environments. By integrating advanced microscopy techniques, artificial intelligence, and robotic experimentation, we can accelerate the discovery and design of resilient materials for a sustainable future. The presentation will highlight recent breakthroughs in autonomous microscopy, computer vision, and machine learning, showcasing their ability to unravel complex material transformations at the atomic scale. The talk will also delve into the challenges and opportunities associated with deploying autonomous systems to probe extreme environments, emphasizing the importance of robust algorithms, real-time data analysis, and adaptive experimentation. The ultimate goal is to empower scientists with unprecedented capabilities to explore, understand, and engineer materials that can withstand the harshest conditions, paving the way for innovations in energy, aerospace, and beyond.

14 SOLAR ENERGY↗

From Chaos to Clarity: Autonomous Materials Discovery for Extreme Environments

The pursuit of advanced functional materials for energy applications demands an understanding of their behavior under the most challenging conditions. Extreme environments, characterized by intense radiation, high temperatures, and corrosive chemistries, push materials to their limits, often revealing unexpected behaviors and degradation pathways. Traditional materials research approaches, relying on trial-and-error experimentation, are often slow and resource-intensive, ill-suited to the complexities of extreme environments. This talk will explore the transformative potential of autonomous materials science in revolutionizing our understanding of materials synthesis and degradation in extreme environments. By integrating advanced microscopy techniques, artificial intelligence, and robotic experimentation, we can accelerate the discovery and design of resilient materials for a sustainable future. The presentation will highlight recent breakthroughs in autonomous microscopy, computer vision, and machine learning, showcasing their ability to unravel complex material transformations at the atomic scale. The talk will also delve into the challenges and opportunities associated with deploying autonomous systems to probe extreme environments, emphasizing the importance of robust algorithms, real-time data analysis, and adaptive experimentation. Our ultimate goal is to empower scientists with unprecedented capabilities to explore, understand, and engineer materials that can withstand the harshest conditions, paving the way for innovations in energy, aerospace, and beyond.

artificial intelligence↗

MRI-Based Computed Tomography Metal Artifact Correction Method for Improving Proton Range Calculation Accuracy

Purpose: Computed tomography (CT) artifacts can severely degrade dose calculation accuracy in proton therapy. Prompted by the recently increased popularity of magnetic resonance imaging (MRI) in the radiation therapy clinic, we developed an MRI-based CT artifact correction method for improving the accuracy of proton range calculations. Methods and Materials: The proposed method replaces corrupted CT data by mapping CT Hounsfield units (HU number) from a nearby artifact-free slice, using a coregistered MRI. MRI and CT volumetric images were registered with use of 3-dimensional (3D) deformable image registration (DIR). The registration was fine-tuned on a slice-by-slice basis by using 2D DIR. Based on the intensity of paired MRI pixel values and HU from an artifact-free slice, we performed a comprehensive analysis to predict the correct HU for the corrupted region. For a proof-of-concept validation, metal artifacts were simulated on a reference data set. Proton range was calculated using reference, artifactual, and corrected images to quantify the reduction in proton range error. The correction method was applied to 4 unique clinical cases. Results: The correction method resulted in substantial artifact reduction, both quantitatively and qualitatively. On respective simulated brain and head and neck CT images, the mean error was reduced from 495 and 370 HU to 108 and 92 HU after correction. Correspondingly, the absolute mean proton range errors of 2.4 cm and 1.7 cm were reduced to less than 2 mm in both cases. Conclusions: Our MRI-based CT artifact correction method can improve CT image quality and proton range calculation accuracy for patients with severe CT artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of various interpolants available in DICE

This report evaluates several interpolants implemented in the Digital Image Correlation Engine (DICe), an image correlation software package developed by Sandia. By interpolants we refer to the basis functions used to represent discrete pixel intensity data as a continuous signal. Interpolation is used to determine intensity values in an image at non - pixel locations. It is also used, in some cases, to evaluate the x and y gradients of the image intensities. Intensity gradients subsequently guide the optimization process. The goal of this report is to inform analysts as to the characteristics of each interpolant and provide guidance towards the best interpolant for a given dataset. This work also serves as an initial verification of each of the interpolants implemented.

97 MATHEMATICS AND COMPUTING↗