Search NASA⌕ Search

SEARCH · Search NASA

Results for “deconvolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

786 records · Page 44

Ionization electron signal processing in single phase LArTPCs. Part II. Data/simulation comparison and performance in MicroBooNE

The single-phase liquid argon time projection chamber (LArTPC) provides a large amount of detailed information in the form of fine-grained drifted ionization charge from particle traces. To fully utilize this information, the deposited charge must be accurately extracted from the raw digitized waveforms via a robust signal processing chain. Enabled by the ultra-low noise levels associated with cryogenic electronics in the MicroBooNE detector, the precise extraction of ionization charge from the induction wire planes in a single-phase LArTPC is qualitatively demonstrated on MicroBooNE data with event display images, and quantitatively demonstrated via waveform-level and track-level metrics. Improved performance of induction plane calorimetry is demonstrated through the agreement of extracted ionization charge measurements across different wire planes for various event topologies. In addition to the comprehensive waveform-level comparison of data and simulation, a calibration of the cryogenic electronics response is presented and solutions to various MicroBooNE-specific TPC issues are discussed. This work presents an important improvement in LArTPC signal processing, the foundation of reconstruction and therefore physics analyses in MicroBooNE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scatter and Blur Corrections for High-Energy X-Ray Radiography

High-energy X-ray radiography is useful as a highly penetrating method for imaging through dense materials. However, the primary modes of interaction of X-rays at these energies involve scattering or the production of secondary high-energy photons, which can interfere with the image. In addition, detector blurring, often resulting from scatter within the detector, can reduce image sharpness. Both of these processes can be mitigated with the use of convolution kernels, with the main challenge being that the proper kernel to use is not known, particularly for the scatter contribution. By radiographing solid slabs of uniform attenuation, we show that point spread functions and material-specific point scatter functions can be determined to significantly reduce the effect of detector blurring and object scatter. Constraining the fits to the slabs and uniform transmission within the slabs is sufficient to recover these functions. A functional form that reproduces the angular distribution of high-energy bremsstrahlung X-rays is presented for recovering point scatter functions. In conclusion, the method is applied to radiographs of objects from bremsstrahlung X-ray sources operating at 4- and 7.5-MV endpoint energies and a significant increase in sharpness is observed.

Blind deconvolution↗

Development of an immersion fiber optic Raman probe for real-time analysis of molten materials

This study presents an advancement in high-temperature Raman spectroscopy, specifically for analyzing molten materials. It introduces an approach by integrating a fiber-optic Raman probe with a copper block protection system designed to endure extreme thermal conditions. The copper block features an open port designed to accommodate an external telescope with a 3 cm focal length, enabling Raman spectra collection in challenging high-temperature environments. A built-in gas channel ensures a continuous flow of argon gas to prevent flux intrusion. The robust copper block acts as a reliable shield, safeguarding the fiber-optic Raman probe within molten materials. This enhancement maintains the probe's integrity and significantly improves its resilience, making it ideal for rigorous investigations of molten substances. This advancement is particularly relevant in metallurgy, where flux materials impact production quality and efficiency. The ability to acquire Raman signals under elevated thermal conditions offers opportunities for studying molecular dynamics, compositional changes, and chemical interactions within molten substances. This introduced direct immersion probing technique has implications, benefiting both scientific and industrial fields. It holds promise for advancing research and exploration in various contexts, from fundamental scientific inquiries to practical applications in metallurgical processes, where flux materials are critical for optimizing production quality and efficiency. Furthermore, this approach enhances the capabilities of high-temperature Raman spectroscopy, making it a valuable tool for investigating molten materials and their properties in diverse settings.

Argon↗

Guide to using Multiple Regression in Excel (MRCX v.1.1) for Removal of River Stage Effects from Well Water Levels

A software tool was created in Fiscal Year 2010 (FY11) that enables multiple-regression correction of well water levels for river-stage effects. This task was conducted as part of the Remediation Science and Technology project of CH2MHILL Plateau Remediation Company (CHPRC). This document contains an overview of the correction methodology and a user’s manual for Multiple Regression in Excel (MRCX) v.1.1. It also contains a step-by-step tutorial that shows users how to use MRCX to correct river effects in two different wells. This report is accompanied by an enclosed CD that contains the MRCX installer application and files used in the tutorial exercises.

99 GENERAL AND MISCELLANEOUS↗

A Critical Examination of Figure of Merit (FOM). Assessing the Goodness-of-Fit in Gamma/X-ray Peak Analysis

In this paper we develop and investigate several criteria for assessing how well a proposed spectral form fits observed spectra. We consider the classical improved figure of merit (FOM) along with several modifications, as well as criteria motivated by Poisson regression from the statistical literature. We also develop a new FOM that is based on the statistical idea of the bootstrap. A spectral simulator has been developed to assess the performance of these different criteria under multiple data configurations.

97 MATHEMATICS AND COMPUTING↗

Performance of methods for SARS-CoV-2 variant detection and abundance estimation within mixed population samples

The accurate identification of SARS-CoV-2 (SC2) variants and estimation of their abundance in mixed population samples (e.g., air or wastewater) is imperative for successful surveillance of community level trends. Assessing the performance of SC2 variant composition estimators (VCEs) should improve our confidence in public health decision making. Here, we introduce a linear regression based VCE and compare its performance to four other VCEs: two re-purposed DNA sequence read classifiers (Kallisto and Kraken2), a maximum-likelihood based method (Lineage deComposition for Sars-Cov-2 pooled samples (LCS)), and a regression based method (Freyja). We simulated DNA sequence datasets of known variant composition from both Illumina and Oxford Nanopore Technologies (ONT) platforms and assessed the performance of each VCE. We also evaluated VCEs performance using publicly available empirical wastewater samples collected for SC2 surveillance efforts. Bioinformatic analyses were performed with a custom NextFlow workflow (C-WAP, CFSAN Wastewater Analysis Pipeline). Relative root mean squared error (RRMSE) was used as a measure of performance with respect to the known abundance and concordance correlation coefficient (CCC) was used to measure agreement between pairs of estimators. Based on our results from simulated data, Kallisto was the most accurate estimator as it had the lowest RRMSE, followed by Freyja. Kallisto and Freyja had the most similar predictions, reflected by the highest CCC metrics. We also found that accuracy was platform and amplicon panel dependent. For example, the accuracy of Freyja was significantly higher with Illumina data compared to ONT data; performance of Kallisto was best with ARTICv4. However, when analyzing empirical data there was poor agreement among methods and variations in the number of variants detected (e.g., Freyja ARTICv4 had a mean of 2.2 variants while Kallisto ARTICv4 had a mean of 10.1 variants). This work provides an understanding of the differences in performance of a number of VCEs and how accurate they are in capturing the relative abundance of SC2 variants within a mixed sample (e.g., wastewater). Such information should help officials gauge the confidence they can have in such data for informing public health decisions.

60 APPLIED LIFE SCIENCES↗