Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed algorithm”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Streamline integration as a method for two-dimensional elliptic grid generation

We propose a new numerical algorithm to construct a structured numerical elliptic grid of a doubly connected domain. Our method is applicable to domains with boundaries defined by two contour lines of a two-dimensional function. Furthermore, we can adapt any analytically given boundary aligned structured grid, which specifically includes polar and Cartesian grids. The resulting coordinate lines are orthogonal to the boundary. Grid points as well as the elements of the Jacobian matrix can be computed efficiently and up to machine precision. In the simplest case we construct conformal grids, yet with the help of weight functions and monitor metrics we can control the distribution of cells across the domain. Our algorithm is parallelizable and easy to implement with elementary numerical methods. We assess the quality of grids by considering both the distribution of cell sizes and the accuracy of the solution to elliptic problems. Among the tested grids these key properties are best fulfilled by the grid constructed with the monitor metric approach. - Graphical abstract: - Highlights: • Construct structured, elliptic numerical grids with elementary numerical methods. • Align coordinate lines with or make them orthogonal to the domain boundary. • Compute grid points and metric elements up to machine precision. • Control cell distribution by adaption functions or monitor metrics.

97 MATHEMATICS AND COMPUTING↗

Coherent x-ray diffraction imaging of paint pigmentparticles by scanning a phase plate modulator

We have implemented a coherent x-ray diffraction imaging technique that scans a phase plate to modulate wave-fronts of the x-ray beam transmitted by samples. The method was applied to measure a decorative alkyd paint containing iron oxide red pigment particles. By employing an iterative algorithm for wave-front modulation phase retrieval, we obtained an image of the paint sample that shows the distribution of the pigment particles and is consistent with the result obtained from a transmission x-ray microscope. The technique has been experimentally proven to be a feasible coherent x-ray imaging method with about 120 nm spatial resolution and was shown to work well with industrially relevant specimens.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Estimation of distributions via multilevel Monte Carlo with stratified sampling

We design and implement a novel algorithm for computing a multilevel Monte Carlo (MLMC) estimator of the joint cumulative distribution function (CDF) of a vector-valued quantity of interest in problems with random input parameters and initial conditions. Our approach combines MLMC with stratified sampling of the input sample space by replacing standard Monte Carlo at each level with stratified Monte Carlo initialized with proportionally allocated samples. We show that the resulting stratified MLMC (sMLMC) algorithm is more efficient than its standard MLMC counterpart due to the additional variance reduction provided by the stratification of the random parameter's domain, especially at the coarsest levels. Additional computational cost savings are obtained by smoothing the indicator function with a Gaussian kernel, which proves to be an efficient and robust alternative to recently developed polynomial-based techniques.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Distributed Coordination of Demand-side Flexible Resources in Microgrid with All-Time Feasibility

The prevalence of distributed renewable generators motivates microgrid operators to exploit demand-side flexible resources (DFRs). Due to their dispersed nature, distributed DFR coordination has been a vibrant research area, while there are several issues awaiting to be addressed. On one hand, DFR power is internally coupled through power flow, while DFR usually cannot access grid information. On the other hand, in time-restricted scenarios, solution feasibility cannot be guaranteed by conventional dual-based algorithms. To fill these gaps, we propose a distributed DFR coordination framework with all-time feasibility. The proposed framework accounts for the distinct access of microgrid entities to grid information. A distributed and all-time feasible algorithm is proposed for optimal DFR coordination, which allows DFRs to make local decisions without violating constraints throughout iterations. The effectiveness of the proposed algorithm is demonstrated through case studies. The impact of peer-to-peer communication links on algorithm convergence is also investigated, which emphasizes the balance between communication investment and algorithm performance.

Li, Hongyi [Iowa State Univ., Ames, IA (United Sta↗

Accurate Automatic Delineation of Heterogeneous Functional Volumes in Positron Emission Tomography for Oncology Applications

Purpose: Accurate contouring of positron emission tomography (PET) functional volumes is now considered crucial in image-guided radiotherapy and other oncology applications because the use of functional imaging allows for biological target definition. In addition, the definition of variable uptake regions within the tumor itself may facilitate dose painting for dosimetry optimization. Methods and Materials: Current state-of-the-art algorithms for functional volume segmentation use adaptive thresholding. We developed an approach called fuzzy locally adaptive Bayesian (FLAB), validated on homogeneous objects, and then improved it by allowing the use of up to three tumor classes for the delineation of inhomogeneous tumors (3-FLAB). Simulated and real tumors with histology data containing homogeneous and heterogeneous activity distributions were used to assess the algorithm's accuracy. Results: The new 3-FLAB algorithm is able to extract the overall tumor from the background tissues and delineate variable uptake regions within the tumors, with higher accuracy and robustness compared with adaptive threshold (T{sub bckg}) and fuzzy C-means (FCM). 3-FLAB performed with a mean classification error of less than 9% +- 8% on the simulated tumors, whereas binary-only implementation led to errors of 15% +- 11%. T{sub bckg} and FCM led to mean errors of 20% +- 12% and 17% +- 14%, respectively. 3-FLAB also led to more robust estimation of the maximum diameters of tumors with histology measurements, with <6% standard deviation, whereas binary FLAB, T{sub bckg} and FCM lead to 10%, 12%, and 13%, respectively. Conclusion: These encouraging results warrant further investigation in future studies that will investigate the impact of 3-FLAB in radiotherapy treatment planning, diagnosis, and therapy response evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-536: Inhomogeneity Correction in Planning of Gamma Knife Treatments for Acoustic Schwannoma

Purpose: To find out the dose difference on targets and organs at risk for the treatment of acoustic schwannoma if the inhomogeneity correction (Convolution algorithm) is applied. Methods: Images of patients treated for acoustic schwannoma with Gamma Knife using TMR 10 algorithm were retrieved from database and replanned with Convolution and TMR 10 algorithm respectively. These patients were treated using a preplan scheme in following: (1) Before the actual treatment day, using the MRI image that was taken without a head frame on the patient's skull, a pre-treatment plan was made based on the default skull coordinates in the Gamma Knife treatment planning system (LGP); (2) then on treatment day, a head frame was placed on the patient's skull, and a CT image was taken. The CT image with head frame was registered and fused with the completed preplan; (3) the treatment plan was finalized and the treatment was delivered. To find out the dosimetry impact of inhomogeneity correction, we used the retrieved CT images to replan the treatment using Convolution algorithm in LGP software version 10.1.1. The dose distributions and the dose volume histograms for targets and OARs were compared for these two dose calculation algorithms. Results: The dose calculated with the Convolution algorithm in general is slightly lower than the one from TMR 10 around the boney area. The effect from the inhomogeneity correction is observable but not significant, and varies with the location of the tumor. Conclusion: Inhomogeneity correction slightly improve the dose accuracy for acoustic schwannoma Gamma Knife treatments although the correction may not be very significant. Our Result provides evidence for dose prescription adjustment to treat acoustic schwannoma. The actual clinical outcome of switching from using TMR10 to using Convolution needs to be further investigated.

60 APPLIED LIFE SCIENCES↗

Stochastic characterization of phase detection algorithms in phase-shifting interferometry

Phase-shifting interferometry (PSI) is the preferred non-contact method for profiling sub-nanometer surfaces. Based on monochromatic light interference, the method computes the surface profile from a set of interferograms collected at separate stepping positions. Errors in the estimated profile are introduced when these positions are not located correctly. In order to cope with this problem, various algorithms that minimize the effects of certain types of stepping errors (linear, sinusoidal, etc.) have been developed. Despite the relatively large number of algorithms suggested in the literature, there is no unified way of characterizing their performance when additional unaccounted random errors are present. Here, we suggest a procedure for quantifying the expected behavior of each algorithm in the presence of independent and identically distributed (i.i.d.) random stepping errors, which can occur in addition to the systematic errors for which the algorithm has been designed. As a result, the usefulness of this method derives from the fact that it can guide the selection of the best algorithm for specific measurement situations.

42 ENGINEERING↗

Influence of robust optimization in intensity-modulated proton therapy with different dose delivery techniques

Purpose: The distal edge tracking (DET) technique in intensity-modulated proton therapy (IMPT) allows for high energy efficiency, fast and simple delivery, and simple inverse treatment planning; however, it is highly sensitive to uncertainties. In this study, the authors explored the application of DET in IMPT (IMPT-DET) and conducted robust optimization of IMPT-DET to see if the planning technique's sensitivity to uncertainties was reduced. They also compared conventional and robust optimization of IMPT-DET with three-dimensional IMPT (IMPT-3D) to gain understanding about how plan robustness is achieved. Methods: They compared the robustness of IMPT-DET and IMPT-3D plans to uncertainties by analyzing plans created for a typical prostate cancer case and a base of skull (BOS) cancer case (using data for patients who had undergone proton therapy at our institution). Spots with the highest and second highest energy layers were chosen so that the Bragg peak would be at the distal edge of the targets in IMPT-DET using 36 equally spaced angle beams; in IMPT-3D, 3 beams with angles chosen by a beam angle optimization algorithm were planned. Dose contributions for a number of range and setup uncertainties were calculated, and a worst-case robust optimization was performed. A robust quantification technique was used to evaluate the plans' sensitivity to uncertainties. Results: With no uncertainties considered, the DET is less robust to uncertainties than is the 3D method but offers better normal tissue protection. With robust optimization to account for range and setup uncertainties, robust optimization can improve the robustness of IMPT plans to uncertainties; however, our findings show the extent of improvement varies. Conclusions: IMPT's sensitivity to uncertainties can be improved by using robust optimization. They found two possible mechanisms that made improvements possible: (1) a localized single-field uniform dose distribution (LSFUD) mechanism, in which the optimization algorithm attempts to produce a single-field uniform dose distribution while minimizing the patching field as much as possible; and (2) perturbed dose distribution, which follows the change in anatomical geometry. Multiple-instance optimization has more knowledge of the influence matrices; this greater knowledge improves IMPT plans' ability to retain robustness despite the presence of uncertainties.

61 RADIATION PROTECTION AND DOSIMETRY↗

Distributed Energy Management for Networked Microgrids with Hardware-in-the-Loop Validation

For the cooperative operation of networked microgrids, a distributed energy management considering network operational objectives and constraints is proposed in this work. Considering various ownership and privacy requirements of microgrids, utility directly interfaced distributed energy resources (DERs) and demand response, a distributed optimization is proposed for obtaining optimal network operational objectives with constraints satisfied through iteratively updated price signals. The alternating direction method of multipliers (ADMM) algorithm is utilized to solve the formulated distributed optimization. The proposed distributed energy management provides microgrids, utility-directly interfaced DERs and responsive demands the opportunity of contributing to better network operational objectives while preserving their privacy and autonomy. Results of numerical simulation using a networked microgrids system consisting of several microgrids, utility directly interfaced DERs and responsive demands validate the soundness and accuracy of the proposed distributed energy management. The proposed method is further tested on a practical two-microgrid system located in Adjuntas, Puerto Rico, and the applicability of the proposed strategy is validated through hardware-in-the-loop (HIL) testing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Poster — Thur Eve — 11: Validation of the orthopedic metallic artifact reduction tool for CT simulations at the Ottawa Hospital Cancer Centre

Metallic implants in patients can produce image artifacts in kilovoltage CT simulation images which can introduce noise and inaccuracies in CT number, affecting anatomical segmentation and dose distributions. The commercial orthopedic metal artifact reduction algorithm (O-MAR) (Philips Healthcare System) was recently made available on CT simulation scanners at our institution. This study validated the clinical use of O-MAR by investigating its effects on CT number and dose distributions. O-MAR corrected and uncorrected images were acquired with a Philips Brilliance Big Bore CT simulator of a cylindrical solid water phantom that contained various plugs (including metal) of known density. CT number accuracy was investigated by determining the mean and standard deviation in regions of interest (ROI) within each plug for uncorrected and O-MAR corrected images and comparing with no-metal image values. Dose distributions were calculated using the Monaco treatment planning system. Seven open fields were equally spaced about the phantom around a ROI near the center of the phantom. These were compared to a “correct” dose distribution calculated by overriding electron densities a no-metal phantom image to produce an image containing metal but no artifacts. An overall improvement in CT number and dose distribution accuracy was achieved by applying the O-MAR correction. Mean CT numbers and standard deviations were found to be generally improved. Exceptions included lung equivalent media, which is consistent with vendor specified contraindications. Dose profiles were found to vary by ±4% between uncorrected or O-MAR corrected images with O-MAR producing doses closer to ground truth.

60 APPLIED LIFE SCIENCES↗

SU-F-19A-01: APBI Brachytherapy Treatment Planning: The Impact of Heterogeneous Dose Calculations

Purpose: To quantify the difference in dose to PTV-EVAL and OARs (skin and rib) as calculated by (TG43) and heterogeneous calculations (CCC). Methods: 25 patient plans (5 Contura and 20 SAVI) were selected for analysis. Clinical dose distributions were computed with a commercially available treatment planning algorithm (TG43-D-(w,w)) and then recomputed with a pre-clinical collapsed cone convolution algorithm (CCCD-( m,m)). PTV-EVAL coverage (V90%, V95%), and rib and skin maximum dose were compared via percent difference. Differences in dose to normal tissue (V150cc, V200cc of PTV-EVAL) were also compared. Changes in coverage and maximum dose to organs at risk are reported in percent change, (100*(TG43 − CCC) / TG43)), and changes in maximum dose to normal tissue are absolute change in cc (TG43 − CCC). Results: Mean differences in V90, V95, V150, and V200 for the SAVI cases were −0.2%, −0.4%, −0.03cc, and −0.14cc, respectively, with maximum differences of −0.78%, −1.7%, 1.28cc, and 1.01cc, respectively. Mean differences in the 0.1cc dose to the rib and skin were −1.4% and −0.22%, respectively, with maximum differences of −4.5% and 16%, respectively. Mean differences in V90, V95, V150, and V200 for the Contura cases were −1.2%, −2.1%, −1.8cc, and −0.59cc, respectively, with maximum differences of −2.0%, −3.16%, −2.9cc, and −0.76cc, respectively. Mean differences in the 0.1cc dose to the rib and skin were −2.6% and −3.9%, respectively, with maximum differences of −3.2% and −5.7%, respectively. Conclusion: The effects of translating clinical knowledge based on D-(w,w) to plans reported in D-(m,m) are minimal (2% or less) on average, but vary based on the type and placement of the device, source, and heterogeneity information.

60 APPLIED LIFE SCIENCES↗

Scalable FBP decomposition for cone-beam CT reconstruction

Filtered Back-Projection (FBP) is a fundamental compute intense algorithm used in tomographic image reconstruction. Cone-Beam Computed Tomography (CBCT) devices use a cone-shaped X-ray beam, in comparison to the parallel beam used in older CT generations. Distributed image reconstruction of cone-beam datasets typically relies on dividing batches of images into different nodes. This simple input decomposition, however, introduces limits on input/output sizes and scalability.We propose a novel decomposition scheme and reconstruction algorithm for distributed FPB. This scheme enables arbitrarily large input/output sizes, eliminates the redundancy arising in the end-to-end pipeline and improves the scalability by replacing two communication collectives with only one segmented reduction. Finally, we implement the proposed decomposition scheme in a framework that is useful for all current-generation CT devices (7th gen). In our experiments using up to 1024 GPUs, our framework can construct 40963 volumes, for real-world datasets, in under 16 seconds (including I/O).

Chen, Peng↗

Identifying and tracking bubbles and drops in simulations: A toolbox for obtaining sizes, lineages, and breakup and coalescence statistics

Knowledge of bubble and drop size distributions in two-phase flows is important for characterizing a wide range of phenomena, including combustor ignition, sonar communication, and cloud formation. The physical mechanisms driving the background flow also drive the time evolution of these distributions. Accurate and robust identification and tracking algorithms for the dispersed phase are necessary to reliably measure this evolution and thereby quantify the underlying mechanisms in interface-resolving flow simulations. The identification of individual bubbles and drops traditionally relies on an algorithm used to identify connected regions. This traditional algorithm can be sensitive to the presence of spurious structures. A cost-effective refinement is proposed to maximize volume accuracy while minimizing the identification of spurious bubbles and drops. An accurate identification scheme is crucial for distinguishing bubble and drop pairs with large size ratios. The identified bubbles and drops need to be tracked in time to obtain breakup and coalescence statistics that characterize the evolution of the size distribution, including breakup and coalescence frequencies, and the probability distributions of parent and child bubble and drop sizes. An algorithm based on mass conservation is proposed to construct bubble and drop lineages using simulation snapshots that are not necessarily from consecutive time steps. These lineages are then used to detect breakup and coalescence events, and obtain the desired statistics. Accurate identification of large-size-ratio bubble and drop pairs enables accurate detection of breakup and coalescence events over a large size range. Accurate detection of successive breakup and coalescence events requires that the snapshot interval be an order of magnitude smaller than the characteristic breakup and coalescence times to capture these successive events while minimizing the identification of repeated confounding events. Together, these algorithms serve as a toolbox for detailed analysis of two-phase simulations, and enable insights into the mechanisms behind bubble and drop formation and evolution in flows of practical importance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spreader-Bar Radiation Detection System Enhancements: A Modeling and Simulation Study

An investigation of radiation detectors on crane-mounted platforms was performed to understand the limitations and optimal capability of these types of systems. Crane-mounted systems are primarily focused on crane-mounted radiation detector systems, where the detectors are mounted on a spreader-bar platform. Spreader bars are attached with cables to a crane at seaports to load and unload containers from cargo ships. The bars can spread from 20 feet to 53 feet using hydraulics, allowing a single bar to move a variety of container lengths. Spreader-bars are also used on straddle carriers, which move containers around the laydown yard in the port. Spreader bar radiation detection (SBRD) systems are commercially available from at least two companies. These systems employ a set of spectroscopic sensors placed on the underside of a gantry crane and held near the top of a cargo container for detection. These systems have been previously tested and some issues and limitations observed. Radiation detectors mounted on spreader-bars are single sided systems (observing cargo only from the top) and it is therefore challenging to obtain the same sensitivity as double-sided systems (for example, portal monitors) especially when considering the possible amounts of intervening cargo that could be present. The approximately exponential attenuation of gamma rays in intervening dense cargo presents an inherent limitation to detection. However, SBRD systems hold detectors closer to the container, have a longer dwell time, and may have lower background (over the ship); all of these aspects help mitigate the single-sided issue. In addition, there are operational considerations that make spreader-bar radiation systems attractive. These include scanning for radiation during other operations (loading, unloading or container movement) which minimizes additional time for scanning, incorporating the radiation detection into existing equipment to minimize initial cost, and in the case of ship unloading, scanning the containers before reaching the laydown yard. This study is focused on researching optimized configurations of SBRD systems, including number of detectors, locations, and best use of detector data, to determine a reasonable limit on the capability of these types of systems. The results will help support decisions on where and how these systems might be effectively deployed, and could be used for future specification development for SBRD acquisition. The next phase of this research and investigation into SBRD systems and quantification of the possible improved capability with an enhanced SBRD is the focus of this report. Supporting this investigation, detailed models of an enhanced SBRD system were created using a 3D radiation transport code, and models were run to simulate the data from sources and background for a realistic cargo-loading port environment. The enhanced SBRD had increased detector material (numbers of detectors) compared to the commercial systems, with a distribution providing more uniform coverage. Measurements using small industrial sources were made with an enhanced SBRD system developed by Sandia National Laboratory to support model validation to establish credibility for the simulations of these threat and background scenarios. A significant simulation effort was undertaken to simulate sources of interest within a 40-foot cargo container. In order to estimate the performance of a generalized SBRD system in scenarios including background and cargo, a highly enriched uranium (HEU) test source (with 3x10 -8 232 U by weight) within a wood cargo model was simulated for a 40-foot cargo container. This source was placed at a variety of locations, and the flux from the source was multiplied as necessary to create estimated minimal detectable quantities (MDQ) figures for various quantities of HEU. Simulated data sets were produced corresponding to a complete container offloading scenario for a large number of statistical realizations. Significant work was performed on both the algorithm development and the container cargo distributions entering the US, and the result of this modeling, validation, and simulation effort was a set of estimates of the performance of a variety of radiation detection algorithms in this cargo-screening environment. In the case of algorithms, a variety of contemporary radiation detection and identification approaches were employed, and the optimal approaches to selecting time and location subsets of detector data were explored. In all cases, algorithm performance was compared, and the best approaches were suggested along with the best expected performance from the enhanced SBRD. In general, template-matching schemes employing a limited set of regression parameters tend to provide best results. The improvements of an enhanced SBRD with increased detector material and improved algorithms result in an effective MDQ of 10 kg of HEU in ~50 percent of the imported cargo in 40-foot containers, assuming a random source location. This is approximately two times the capability of the estimated performance of the commercial systems. For an MDQ of the 10 kg HEU source located in the worst location (bottom of the 40-foot container), the volume of cargo scanned drops to 10% for the enhanced SBRD, again a factor of two or more larger than the commercial systems. Enhancing the SBRD systems by adding more detectors, providing a more uniform coverage, and incorporating more advanced algorithms will result in a significant increase in capability. Although this investigation provided some indication of the performance capabilities of an enhanced SBRD system, additional work is needed to estimate the capability for other container configurations, such as the 20 and 45 foot containers. Since the 20-foot container weight limit is similar to the 40-foot, more dense cargo is typically shipped in 20-foot containers. This will result in a smaller percentage of cargo scanned for the 20-foot containers (for a particular source quantity) compared to the 40-foot containers. In addition to other configuration, other source material needs to be investigated to understand the capabilities for the entire threat space, where only HEU is considered in this work.

crane-mounted↗

Stochastic simulation of electron avalanches on supercomputers

In the paper, we present a three-dimensional parallel Monte Carlo algorithm named ELSHOW which is developed for simulation of electron avalanches in gases. Parallel implementation of the ELSHOW was made on supercomputers with different architectures (massive parallel and hybrid ones). Using the ELSHOW, calculations of such integral characteristics as the number of particles in an avalanche, the coefficient of impact ionization, the drift velocity, and the others were made. Also, special precise computations were made to select an appropriate size of the time step using the technique of dependent statistical tests. Particularly, the algorithm consists of special methods of distribution modeling, a lexicographic implementation scheme for “branching” of trajectories, justified estimation of functionals. A comparison of the obtained results for nitrogen with previously published theoretical and experimental data was made.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

HIGH-RESOLUTION LINEAR POLARIMETRIC IMAGING FOR THE EVENT HORIZON TELESCOPE

Images of the linear polarizations of synchrotron radiation around active galactic nuclei (AGNs) highlight their projected magnetic field lines and provide key data for understanding the physics of accretion and outflow from supermassive black holes. The highest-resolution polarimetric images of AGNs are produced with Very Long Baseline Interferometry (VLBI). Because VLBI incompletely samples the Fourier transform of the source image, any image reconstruction that fills in unmeasured spatial frequencies will not be unique and reconstruction algorithms are required. In this paper, we explore some extensions of the Maximum Entropy Method (MEM) to linear polarimetric VLBI imaging. In contrast to previous work, our polarimetric MEM algorithm combines a Stokes I imager that only uses bispectrum measurements that are immune to atmospheric phase corruption, with a joint Stokes Q and U imager that operates on robust polarimetric ratios. We demonstrate the effectiveness of our technique on 7 and 3 mm wavelength quasar observations from the VLBA and simulated 1.3 mm Event Horizon Telescope observations of Sgr A* and M87. Consistent with past studies, we find that polarimetric MEM can produce superior resolution compared to the standard CLEAN algorithm, when imaging smooth and compact source distributions. As an imaging framework, MEM is highly adaptable, allowing a range of constraints on polarization structure. Polarimetric MEM is thus an attractive choice for image reconstruction with the EHT.

79 ASTRONOMY AND ASTROPHYSICS↗

Application of the MCMC Method for the Calibration of DSMC Parameters

A Markov Chain Monte Carlo (MCMC) algorithm was employed to obtain a calibrated distribution for the hard sphere diameter, the VHS reference diameter, and the temperature viscosity exponent of argon, for use in the Direct Simulation Monte Carlo (DSMC) method. Shock-tube experiments from Alsmeyer [1] were used to provide the necessary calibration data for use in the MCMC method. The DSMC method used in this work employs the algorithm of Bird [2], with modifications to allow for the efficient simulation of a 1D shock. When calibrating for the hard sphere diameter (the temperature viscosity exponent is set to 0.5 for the hard sphere method), the results of the MCMC method agree with a simple brute-force method, and a single value for the hard-sphere diameter is obtained. For the VHS method, however, when simultaneously calibrating the VHS reference diameter and the temperature viscosity exponent, we find that normalized density data alone does not provide sufficient information to obtain a single solution for both parameters. Instead we find a band in parameter space where acceptable solutions are obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗