Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy conservation code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Managing the Drivers of Air Flow and Water Vapor Transport in Existing Single-Family Homes

This report is a revision of an earlier report titled: Measure Guideline: Managing the Drivers of Air Flow and Water Vapor Transport in Existing Single-Family Homes. Revisions include: Information in the text box on page 1 was revised to reflect the most accurate information regarding classifications as referenced in the 2012 International Residential Code. “Measure Guideline” was dropped from the title of the report. An addition was made to the reference list.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Selecting Ventilation Systems for Existing Homes

This report, developed by Building America research team CARB, addresses adding or improving mechanical ventilation systems to existing homes. The goal of this report is to assist decision makers and contractors in making informed decisions when selecting ventilation systems for homes. With more air-sealed envelopes, a mechanical means of removing contaminants is critical for indoor environmental quality and building durability. The purpose of ventilation is to remove contaminants from homes, and this report discusses where, when, and how much ventilation is appropriate in a home, including examination of relevant codes and standards. Choosing the "best" system is not always straightforward; selecting a system involves balancing performance, efficiency, cost, required maintenance, and several other factors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Completing the Circuit: Workforce Development for Advanced Building Construction and Grid-Interactive Efficient Buildings

This paper will present key findings from a future-oriented qualitative study investigating likely futures for the next 5-10 years in the architecture, engineering, construction, and operations industry. This research offers an original contribution to the buildings industry by articulating an actionable framework to more effectively build connections between built environment fields. Whereas the ideal of interdisciplinary, research driven practice underlies the approach to pedagogy at many schools of architecture, innovation in the profession, such as the integrated design process, has been limited. This project applies Legitimation Code Theory (LCT) to the analysis of data gathered from interviews and a review of industry reports.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

THREE-DIMENSIONAL SIMULATIONS OF MAGNETOHYDRODYNAMIC TURBULENCE BEHIND RELATIVISTIC SHOCK WAVES AND THEIR IMPLICATIONS FOR GAMMA-RAY BURSTS

Relativistic astrophysical phenomena such as gamma-ray bursts (GRBs) and active galactic nuclei often require long-lived strong magnetic fields that cannot be achieved by shock compression alone. Here, we report on three-dimensional special-relativistic magnetohydrodynamic (MHD) simulations that we performed using a second-order Godunov-type conservative code to explore the amplification and decay of macroscopic turbulence dynamo excited by the so-called Richtmyer-Meshkov instability (RMI; a Rayleigh-Taylor-type instability). This instability is an inevitable outcome of interactions between shock and ambient density fluctuations. We find that the magnetic energy grows exponentially in a few eddy-turnover times because of field-line stretching and then, following the decay of kinetic turbulence, decays with a temporal power-law exponent of -0.7. The magnetic energy fraction can reach {epsilon}{sub B} {approx} 0.1 but depends on the initial magnetic field strength, which can diversify the observed phenomena. We find that the magnetic energy grows by at least two orders of magnitude compared to the magnetic energy immediately behind the shock, provided the kinetic energy of turbulence injected by the RMI is greater than the magnetic energy. This minimum degree of amplification does not depend on the amplitude of the initial density fluctuations, while the growth timescale and the maximum magnetic energy depend on the degree of inhomogeneity in the density. The transition from Kolmogorov cascade to MHD critical balance cascade occurs at {approx}1/10th the initial inhomogeneity scale, which limits the maximum synchrotron polarization to less than {approx}2%. We derive analytical formulas for these numerical results and apply them to GRBs. New results include the avoidance of electron cooling with RMI turbulence, the turbulent photosphere model via RMI, and the shallow decay of the early afterglow from RMI. We also perform a simulation of freely decaying turbulence with relativistic velocity dispersion. We find that relativistic turbulence begins to decay much more quickly than one eddy-turnover time because of rapid shock dissipation, which does not support the relativistic turbulence model by Narayan and Kumar.

79 ASTRONOMY AND ASTROPHYSICS↗

Estimation of Seismic Load Demand for a Wind Turbine in the Time Domain: Preprint

Turbines installed in seismically active regions such as the Pacific Rim or the Mediterranean must consider loads induced by base shaking from an earthquake. To account for this earthquake risk, current International Electrotechnical Commission (IEC) certification requirements provide a simplified method for calculating seismic loads which is intended to be conservative. Through the addition of capabilities, it is now possible to simulate earthquake loading of a wind turbine in conjunction other load sources such as wind and control system behavior using the FAST code. This paper presents a comparison of three earthquake loading scenarios of the National Renewable Energy Laboratory (NREL) offshore 5-MW baseline wind turbine: idling; continued operation through an earthquake; and an emergency shutdown initiated by an earthquake. Using a set of 22 earthquake records, simulations are conducted for each load case. A summary of the resulting tower moment demand is presented to assess the influence of operational state on the resulting structural demand.

17 WIND ENERGY↗

Energy Production Demonstrator and Material Testing Station optimization for Megawatt proton beams

A simulation study of the Energy Production Demonstrator (EPD) concept – a solid heavy metal target irradiated by GeV-range intense proton beams and producing more energy than consuming – is carried out. Neutron production, fission, energy deposition, energy gain, testing volume and helium production are simulated using the MARS15 code for tungsten, thorium, and natural uranium targets in the proton energy range 0.5–120 GeV. This study shows that the proton energy range of 2–4 GeV is optimal for both a nat U EPD and the tungsten-based testing station for proton accelerator facilities. Simulation-based conservative estimates not including breeding and fission of plutonium suggest the proton beam current sufficient to produce 1 GW of thermal output power with the nat U EPD while supplying a relatively small fraction of that power to operate the accelerator. The thermal analysis has been performed and has shown that the EPD with a parallel proton beam feeding the core has a potential problem due to a possible core meltdown. In conclusion, a scheme has been proposed with a beam steering on the outer surface of the target; its thermal analysis indicates that slicing the target in shorter parts and maintaining a temperature of 25 °C on their surfaces would to avoid the target meltdown.

43 PARTICLE ACCELERATORS↗

Energy-saving potential evaluation for primary schools with occupant-centric controls

Recent studies demonstrated that there is significant energy-saving potential for primary schools, which heating, ventilation, and air-conditioning (HVAC) systems with occupant-centric control (OCC) is an excellent candidate to save energy. However, such an energy impact has yet to be evaluated for different climate zones as well as different energy code versions, but is critical for technology transfer and deployment. Therefore, this paper conducts comprehensive evaluation on the energy-saving potentials for the primary schools with two advanced OCC strategies: presence-based and counting-based. In this work, ninety-six building energy models with stochastic behavior of occupants are developed and simulated, which consist of two building energy code versions, 16 climate zones, and baseline case (without OCC) and two advanced cases (with OCC). To evaluate the energy saving potentials for OCC, primary schools in the U.S. are used as an example. The results show that there is significant energy-saving potential for primary schools by considering OCC strategies, especially the counting-based case. The energy-saving potential is up to 10.2% for presence-based OCC and 12.41% for counting-based OCC. Furthermore, both climate and code version have a significant impact on energy savings from OCC strategies. The energy-saving potentials vary from 1.79% to 12.41% for different climates and code versions. This evaluation can also contribute to quantify the nationwide energy saving potential for other countries.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Unitary qubit lattice algorithm for three-dimensional vortex solitons in hyperbolic self-defocusing media

To obtain stable vortex structures in three-dimensional (3D) nonlinear optics, Efremidis et al. (2007) have introduced a generalized Nonlinear Schrodinger equation (NLS) in which the transverse quantum vortex components are stabilized by a longitudinal bright soliton: i.e., the elliptic operator ∇ 2 is replaced by its hyperbolic counterpart ∇ ⊥ 2 - ∂ 2 / ∂ z 2 . A new 3D mesoscopic qubit unitary lattice algorithm is developed for this generalized NLS. One introduces 2 qubits for each lattice site and entangles them with a local unitary collision operator. This entanglement is then spread throughout the lattice by nearest neighbor streaming. These interwined operators lead to an extremely well parallelized code on classical supcomputers while their unitary structure will permit encoding onto a quantum computer. Somewhat unexpectedly, the hyperbolic operator can be realized from variations in the collision operator, without introducing variations in the streaming operator. The initial line vortices are generated by Pade asymptotics. The energy constraint is conserved to 10 digit accuracy.

3D solitons↗

A kinetic line-driven radiation operator and its application to Gyrokinetics

A velocity dependent, kinetic model for line radiation is developed for continuum kinetic codes. It has been implemented in the full-f gyrokinetic code Gkeyll. The total radiation for a charge state is modeled as an advection in velocity space with a form of $\nabla_v \cdot(v\nu(v)f(v))$, guaranteeing particle conservation. The velocity dependence (in the form of an effective frequency $\nu(v)$) is found through fitting the energy loss of the operator, i.e. the second velocity moment, to the radiation data in the OpenADAS database. Therefore, each individual transition does not need to be evaluated every time step, significantly reducing the computational cost of including line radiation in a kinetic model. The dependence on velocity instead of the usual, temperature, allows the radiation to be computed from non-Maxwellian electron distribution functions: We benchmark the model against a collisional radiative model using isotropic non-Maxwellian distribution functions. A velocity dependent model of radiation can more accurately describe the radiation in the more kinetic regimes expected in reactor-scale devices. The velocity dependence qualitatively captures the quantum mechanical need for a minimum velocity before any radiation occurs.

kinetic↗

AMR Code Simulations of Turbulent Combustion in Confined and Unconfined SDF Explosions

A heterogeneous continuum model is proposed to describe the dispersion and combustion of an aluminum particle cloud in an explosion. It combines the gas-dynamic conservation laws for the gas phase with a continuum model for the dispersed phase, as formulated by Nigmatulin. Inter-phase mass, momentum and energy exchange are prescribed by phenomenological models. It incorporates a combustion model based on the mass conservation laws for fuel, air and products; source/sink terms are treated in the fast-chemistry limit appropriate for such gas dynamic fields, along with a model for mass transfer from the particle phase to the gas. The model takes into account both the afterburning of the detonation products of the booster with air, and the combustion of the Al particles with air. The model equations were integrated by high-order Godunov schemes for both the gas and particle phases. Numerical simulations of the explosion fields from 1.5-g Shock-Dispersed-Fuel (SDF) charge in a 6.6 liter calorimeter were used to validate the combustion model. Then the model was applied to 10-kg Al-SDF explosions in a vented two-room structure and in an unconfined height-of-burst explosion. Computed pressure histories are in reasonable (but not perfect) agreement with measured waveforms. Differences are caused by physical-chemical kinetic effects of particle combustion which induce ignition delays in the initial reactive blast wave and quenching of reactions at late times. Current simulations give initial insights into such modeling issues.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Appendix C – GPRA06 Building Technologies (BT) Program Documentation

The Residential Building Energy Codes project improves the minimum or baseline energy efficiency of new residential buildings requiring code perm its. The project promulgates upgraded energy-efficiency requirements for residential buildings. Similarly, the project works with model energy code groups to upgrade the energy-efficiency requirements of their codes. Federal, state, and local jurisdictions then adopt and implement these upgraded federal and model energy codes. The long-term goal is to improve the minimum energy efficiency by 20% to 25% in new low-rise residential building construction.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Efficient and Zero Net Energy-Ready Plug Loads

Plug loads are the devices plugged into common electrical outlets. Modern buildings contain hundreds of these devices which, together, are responsible for at least 25 percent of the energy use in California buildings. Energy consumed by plug loads is increasing because the “Internet of Things” is, to a great extent, the “Internet of Plug Loads.” This project developed technologies that will reduce the energy use of plug loads. Two crosscutting strategies were investigated in detail: (1) technologies to reduce standby power use to near zero, and (2) methods to increase the use of direct current (DC) as a power source. Two new approaches to reduce standby to near zero were developed and have potential applicability to a wide range of devices. Prototype DC appliances were developed to demonstrate energy savings by bypassing power supplies and avoiding other losses. Networks of DC-powered devices can save even more energy and provide other benefits, such as resiliency during power outages. A unique category of energy-using devices was identified that provide life safety, health, and security to building occupants. Their installation or use is dictated by building codes, health providers, insurance companies, and other entities—none of whom would ordinarily prioritize energy efficiency. In the case of ground fault circuit interrupts (GFCIs), savings of 80 percent appear possible, simply by adopting the most efficient designs. Home medical equipment, particularly oxygen concentrators, are a rising category of energy use where significant savings are possible. This report also reviews the codes, standards, and other policies that affect energy use of plug loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Implications of In-Line Filtration in California

Occupant concern about indoor air quality (IAQ) issues has led to the increased use of more effective air filters in residential heating and cooling systems. This study performed measurements in ten California houses to determine the effects of changing filter performance and related characteristics on the energy use of the heating and cooling systems. Multiple filters were evaluated covering a wide range of filter effectiveness from simple low filtration fiberglass filters up to high efficiency filters that might be used by occupants concerned about IAQ. Sophisticated analysis and simulation tools used the field-testing results to determine filter impacts for a wide range of parameters and California climates. The results indicate that for MERV 10/11/13 filters the effects on energy use are moderate (<5%) over a wide range of performance conditions and climates. Using higher MERV 16 filters can lead to significantly increased energy use (>5%). The high airflow resistance of MERV 16 filters led to excess noise in some test houses from air bypassing the filter and the blower motor. Filter loading rates varied more from house to house than by MERV rating and overall were quite low in many of the homes. Filter related energy use does not need to be addressed for filters of MERV 10/11/13 and MERV 16 filters should only be used with low leakage tested ducts unless the filter is mounted at the blower compartment. MERV 16 filters should only be used if the filter area is sufficient to prevent noise issues and if the duct system has low air flow resistance and low leakage. Filters should be labeled for their air flow resistance, or static pressure at a particular flow rate, that would allow codes and standards to reference a particular performance specification and allow contractors and homeowners to make informed purchases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Kinetic particle simulations in a global toroidal geometry

The gyrokinetic toroidal code has been upgraded for global simulations by coupling the core and scrape-off layer regions across the separatrix with field-aligned particle-grid interpolations. A fully kinetic particle pusher for high frequency waves (ion cyclotron frequency and beyond) and a guiding center pusher for low frequency waves have been implemented using cylindrical coordinates in a global toroidal geometry. The two integrators correctly capture the particle orbits and agree well with each other, conserving energy and canonical angular momentum. As a verification and application of this new capability, ion guiding center simulations have been carried out to study ion orbit losses at the edge of the DIII-D tokamak for single null magnetic separatrix discharges. The ion loss conditions are examined as a function of the pitch angle for cases without and with a radial electric field. We report the simulations show good agreement with past theoretical results and with the experimentally observed feature in which high energy ions flow out along the ion drift orbits and then hit the divertor plates. A measure of the ion direct orbit loss fraction shows that the loss fraction increases with the ion energy for DIII-D in the initial velocity space. Finally, as a further verification of the capability of the new code, self-consistent simulations of zonal flows in the core region of the DIII-D tokamak were carried out. All DIII-D simulations were performed in the absence of turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of the parallel nonlinearity on zonal flows and heat transport in global gyrokinetic particle-in-cell simulations

In this paper, the influence of the parallel nonlinearity on zonal flows and heat transport in global particle-in-cell ion-temperature-gradient simulations is studied. Although this term is in theory orders of magnitude smaller than the others, several authors [L. Villard, P. Angelino, A. Bottino et al., Plasma Phys. Contr. Fusion 46, B51 (2004); L. Villard, S. J. Allfrey, A. Bottino et al., Nucl. Fusion 44, 172 (2004); J. C. Kniep, J. N. G. Leboeuf, and V. C. Decyck, Comput. Phys. Commun. 164, 98 (2004); J. Candy, R. E. Waltz, S. E. Parker et al., Phys. Plasmas 13, 074501 (2006)] found different results on its role. The study is performed using the global gyrokinetic particle-in-cell codes TORB (theta-pinch) [R. Hatzky, T. M. Tran, A. Koenies et al., Phys. Plasmas 9, 898 (2002)] and ORB5 (tokamak geometry) [S. Jolliet, A. Bottino, P. Angelino et al., Comput. Phys. Commun. 177, 409 (2007)]. In particular, it is demonstrated that the parallel nonlinearity, while important for energy conservation, affects the zonal electric field only if the simulation is noise dominated. When a proper convergence is reached, the influence of parallel nonlinearity on the zonal electric field, if any, is shown to be small for both the cases of decaying and driven turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Linearised Fokker–Planck collision model for gyrokinetic simulations

We introduce a gyrokinetic, linearised Fokker–Planck collision model that satisfies conservation laws and is accurate at arbitrary collisionalities. The differential test-particle component of the operator is exact; the integral field-particle component is approximated using a spherical harmonic and a modified Laguerre polynomial expansion developed by Hirshman and Sigmar (1976 Phys. Fluids 19 1532). The numerical methods of the implementation in the δf-gyrokinetic code stella (Barnes et al 2019 J. Comput. Phys. 391 365–80) are discussed, and conservation properties of the operator are demonstrated. The collision model is then benchmarked against the collision model of the gyrokinetic solver GS2 in the limiting cases of a reduced test-particle collision operator and energy- and momentum-conserving operator. The accuracy of the full collision model is investigated by solving the parallel Spitzer-Härm problem for the transport coefficients. It is shown that retaining collisional energy flux and higher-order terms in the field-particle operator reduces errors in the transport coefficients from 10%–25% for a simple momentum- and energy-conserving model to under 1%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fenestration System Performance Research, Testing, and Evaluation

The US DOE was and is instrumental to NFRC's beginning and its continued success. The 2005 to 2009 funding enables NFRC to continue expanding and create new, improved ratings procedures. Research funded by the US DOE enables increased fenestration energy rating accuracy. International harmonization efforts supported by the US DOE allow the US to be the global leader in fenestration energy ratings. Many other governments are working with the NFRC to share its experience and knowledge toward development of their own national fenestration rating process similar to the NFRC's. The broad and diverse membership composition of NFRC allows anyone with a fenestration interest to come forward with an idea or improvement to the entire fenestration community for consideration. The NFRC looks forward to the next several years of growth while remaining the nation's resource for fair, accurate, and credible fenestration product energy ratings. NFRC continues to improve its rating system by considering new research, methodologies, and expanding to include new fenestration products. Currently, NFRC is working towards attachment energy ratings. Attachments are blinds, shades, awnings, and overhangs. Attachments may enable a building to achieve significant energy savings. An NFRC rating will enable fair competition, a basis for code references, and a new ENERGY STAR product category. NFRC also is developing rating methods to consider non specular glazing such as fritted glass. Commercial applications frequently use fritted glazing, but no rating method exists. NFRC is testing new software that may enable this new rating and contribute further to energy conservation. Around the world, many nations are seeking new energy conservation methods and NFRC is poised to harmonize its rating system assisting these nations to better manage and conserve energy in buildings by using NFRC rated and labeled fenestration products. As this report has shown, much more work needs to be done to continues research to improve existing ratings and develop new ones. NFRC needs to continue the work it has begun in several nations to implement the NFRC rating system that has been introduced. Many nations are eager to accept the expertise NFRC can offer to achieve energy conservation goals. NFRC looks forward to a continues partnership with the US Department of Energy to cooperatively achieve both.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗