Search NASA⌕ Search

SEARCH · Search NASA

Results for “error fields”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Spin-orbit couplings within the equation-of-motion coupled-cluster framework: Theory, implementation, and benchmark calculations

We present a formalism and an implementation for calculating spin-orbit couplings (SOCs) within the EOM-CCSD (equation-of-motion coupled-cluster with single and double substitutions) approach. The following variants of EOM-CCSD are considered: EOM-CCSD for excitation energies (EOM-EE-CCSD), EOM-CCSD with spin-flip (EOM-SF-CCSD), EOM-CCSD for ionization potentials (EOM-IP-CCSD) and electron attachment (EOM-EA-CCSD). We employ a perturbative approach in which the SOCs are computed as matrix elements of the respective part of the Breit-Pauli Hamiltonian using zeroth-order non-relativistic wave functions. We follow the expectation-value approach rather than the response-theory formulation for property calculations. Both the full two-electron treatment and the mean-field approximation (a partial account of the two-electron contributions) have been implemented and benchmarked using several small molecules containing elements up to the fourth row of the periodic table. The benchmark results show the excellent performance of the perturbative treatment and the mean-field approximation. When used with an appropriate basis set, the errors with respect to experiment are below 5% for the considered examples. The findings regarding basis-set requirements are in agreement with previous studies. The impact of different correlation treatment in zeroth-order wave functions is analyzed. Overall, the EOM-IP-CCSD, EOM-EA-CCSD, EOM-EE-CCSD, and EOM-SF-CCSD wave functions yield SOCs that agree well with each other (and with the experimental values when available). Using an EOM-CCSD approach that provides a more balanced description of the target states yields more accurate results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Accurate determination of solvation free energies of neutral organic compounds from first principles

The main goal of molecular simulation is to accurately predict experimental observables of molecular systems. Another long-standing goal is to devise models for arbitrary neutral organic molecules with little or no reliance on experimental data. While separately these goals have been met to various degrees, for an arbitrary system of molecules they have not been achieved simultaneously. For biophysical ensembles that exist at room temperature and pressure, and where the entropic contributions are on par with interaction strengths, it is the free energies that are both most important and most difficult to predict. We compute the free energies of solvation for a diverse set of neutral organic compounds using a polarizable force field fitted entirely to ab initio calculations. The mean absolute errors (MAE) of hydration, cyclohexane solvation, and corresponding partition coefficients are 0.2 kcal/mol, 0.3 kcal/mol and 0.22 log units, i.e. within chemical accuracy. The model (ARROW FF) is multipolar, polarizable, and its accompanying simulation stack includes nuclear quantum effects (NQE). The simulation tools’ computational efficiency is on a par with current state-of-the-art packages. The construction of a wide-coverage molecular modelling toolset from first principles, together with its excellent predictive ability in the liquid phase is a major advance in biomolecular simulation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gyrokinetic neoclassical study of the bootstrap current in the tokamak edge pedestal with fully non-linear Coulomb collisions

As a follow-up on the drift-kinetic study of the non-local bootstrap current in the steep edge pedestal of tokamak plasma by Koh et al. [Phys. Plasmas 19, 072505 (2012)], a gyrokinetic neoclassical study is performed with gyrokinetic ions and drift-kinetic electrons. Besides the gyrokinetic improvement of ion physics from the drift-kinetic treatment, a fully non-linear Fokker-Planck collision operator—that conserves mass, momentum, and energy—is used instead of Koh et al.'s linearized collision operator in consideration of the possibility that the ion distribution function is non-Maxwellian in the steep pedestal. An inaccuracy in Koh et al.'s result is found in the steep edge pedestal that originated from a small error in the collisional momentum conservation. The present study concludes that (1) the bootstrap current in the steep edge pedestal is generally smaller than what has been predicted from the small banana-width (local) approximation [e.g., Sauter et al., Phys. Plasmas 6, 2834 (1999) and Belli et al., Plasma Phys. Controlled Fusion 50, 095010 (2008)], (2) the plasma flow evaluated from the local approximation can significantly deviate from the non-local results, and (3) the bootstrap current in the edge pedestal, where the passing particle region is small, can be dominantly carried by the trapped particles in a broad trapped boundary layer. A new analytic formula based on numerous gyrokinetic simulations using various magnetic equilibria and plasma profiles with self-consistent Grad-Shafranov solutions is constructed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Physics-constrained deep learning of nonlinear normal modes of spatiotemporal fluid flow dynamics

In this study, we present a physics-constrained deep learning method to discover and visualize from data the invariant nonlinear normal modes (NNMs) which contain the spatiotemporal dynamics of the fluid flow potentially containing strong nonlinearity. Specifically, we develop a NNM-physics-constrained convolutional autoencoder (NNM-CNN-AE) integrated with a multi-temporal-step dynamics prediction block to learn the nonlinear modal transformation, the NNMs containing the spatiotemporal dynamics of the flow, and reduced-order reconstruction and long-time future-state prediction of the flow fields, simultaneously. In test cases, we apply the developed method to analyze different flow regimes past a cylinder, including laminar flows with low Reynolds number in transient and steady states (RD = 100) and high Reynolds number flow (RD = 1000), respectively. The results indicate that the identified NNMs are able to reveal the nonlinear spatiotemporal dynamics of these flows, and the NNMs-based reduced-order modeling consistently achieves better accuracy with orders of magnitudes smaller errors in construction and prediction of the nonlinear velocity and vorticity fields, compared to the linear proper orthogonal decomposition (POD) method and the Koopman-constrained-CNN-AE using the same number or dimension of modes. We perform an analysis of the modal energy distribution of NNMs and find that compared to POD modes, the few fundamental NNMs capture a very high level of total energy of the flow, which is advantageous for reduced-order modeling and representation of the complex flows. Finally, we discuss the potentials and limitations of the presented method.

Mechanics↗

Communication: Quantitative multi-site frequency maps for amide I vibrational spectroscopy

An accurate method for predicting the amide I vibrational spectrum of a given protein structure has been sought for many years. Significant progress has been made recently by sampling structures from molecular dynamics simulations and mapping local electrostatic variables onto the frequencies of individual amide bonds. Agreement with experiment, however, has remained largely qualitative. Previously, we used dipeptide fragments and isotope-labeled constructs of the protein G mimic NuG2b as experimental standards for developing and testing amide I frequency maps. Here, we combine these datasets to test different frequency-map models and develop a novel method to produce an optimized four-site potential (4P) map based on the CHARMM27 force field. Together with a charge correction for glycine residues, the optimized map accurately describes both experimental datasets, with average frequency errors of 2–3 cm{sup −1}. This 4P map is shown to be convertible to a three-site field map which provides equivalent performance, highlighting the viability of both field- and potential-based maps for amide I spectral modeling. The use of multiple sampling points for local electrostatics is found to be essential for accurate map performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessing Impacts of Waves on Hub-Height Winds off the U.S. West Coast Using Lidar Buoys and Coupled Modeling Approaches

Given the importance of offshore wind energy development to the U.S. clean energy targets, it is vital to be able to characterize the wind resource in that environment accurately. Toward that end, two Bureau of Ocean Energy Management buoys equipped with Doppler lidar are being maintained by Pacific Northwest National Laboratory on behalf of the Department of Energy and deployed to regions of potential offshore wind development. In addition to standard meteorological and oceanographic measurements, the buoys document the wind profile between about 40 m and 250 m above the sea surface through Doppler lidar retrievals. After a multiyear deployment of two buoys along the U.S. East Coast, the buoys were redeployed to the U.S. West coast from 2020 – 2022 to locations near the Humboldt and Morro Bay lease areas. The buoys provide nearly continuous, multiyear datasets that can be used to evaluate predictions of hub-height (~100 m) wind speed for standard atmospheric models in the region. In the absence of measurements at the study site, offshore wind developers rely on model-based data to assess site conditions. Potential sources of model error in this environment include under-resolution or misrepresentation of coastal topographically forced flows, marine boundary layer dynamics and the evolution of their associated cloud and turbulence fields, the role of upwelling and other currents on surface heat fluxes into the boundary layer, and the impact of wave fields on surface momentum fluxes and thus the wind speed profile. In particular, most predictive models of wind speed do not predict wave fields at all, relying on parameterizations to represent their effects. In thus study, we focus on evaluating the role of wind / wave interactions on modeled hub-height wind speed and error by using the Coupled Ocean–Atmosphere–Wave–Sediment–Transport Modeling System to capture two-way interactions between an atmospheric model (Weather Research and Forecasting (WRF)) and a wave model (WAVEWATCHIII (WW3)) and compare to both stand-alone WRF and one-way coupled WRF / WW3 configurations. Our approach is similar to that used in Gaudet et al. (2022) to evaluate wind / wave coupling over the U.S. East Coast, but applied to the very different environment of the U.S. West Coast. We show examples for two cases, a cold-season frontal case and a warm-season low-level jet case. We find that wind / wave coupling makes little impact on model error for these cases at the location of the lidar buoys, for which other misrepresentations of model physics seems to be responsible for model-observation discrepancies. However, domain-wide evaluations, which also make use of the National Buoy Data Center network, show that a two-way coupling approach is less prone to systematic errors in the hub-height wind field than the one-way coupled approach. WRF resolution of kilometer-scale or less is needed to properly capture the sharp wind speed gradients that can be found along the coastline, and WW3 simulations driven by the downscaled WRF produce better bulk and spectral wave fields when compared to observations. Implications of the results for wind resource characterization are then discussed.

17 WIND ENERGY↗

Characterization of the onboard imaging unit for the first clinical magnetic resonance image guided radiation therapy system

Purpose: To characterize the performance of the onboard imaging unit for the first clinical magnetic resonance image guided radiation therapy (MR-IGRT) system. Methods: The imaging performance characterization included four components: ACR (the American College of Radiology) phantom test, spatial integrity, coil signal to noise ratio (SNR) and uniformity, and magnetic field homogeneity. The ACR phantom test was performed in accordance with the ACR phantom test guidance. The spatial integrity test was evaluated using a 40.8 × 40.8 × 40.8 cm{sup 3} spatial integrity phantom. MR and computed tomography (CT) images of the phantom were acquired and coregistered. Objects were identified around the surfaces of 20 and 35 cm diameters of spherical volume (DSVs) on both the MR and CT images. Geometric distortion was quantified using deviation in object location between the MR and CT images. The coil SNR test was performed according to the national electrical manufacturers association (NEMA) standards MS-1 and MS-9. The magnetic field homogeneity test was measured using field camera and spectral peak methods. Results: For the ACR tests, the slice position error was less than 0.10 cm, the slice thickness error was less than 0.05 cm, the resolved high-contrast spatial resolution was 0.09 cm, the resolved low-contrast spokes were more than 25, the image intensity uniformity was above 93%, and the percentage ghosting was less than 0.22%. All were within the ACR recommended specifications. The maximum geometric distortions within the 20 and 35 cm DSVs were 0.10 and 0.18 cm for high spatial resolution three-dimensional images and 0.08 and 0.20 cm for high temporal resolution two dimensional cine images based on the distance-to-phantom-center method. The average SNR was 12.0 for the body coil, 42.9 for the combined torso coil, and 44.0 for the combined head and neck coil. Magnetic field homogeneities at gantry angles of 0°, 30°, 60°, 90°, and 120° were 23.55, 20.43, 18.76, 19.11, and 22.22 ppm, respectively, using the field camera method over the 45 cm DSV. Conclusions: The onboard imaging unit of the first commercial MR-IGRT system meets ACR, NEMA, and vendor specifications.

60 APPLIED LIFE SCIENCES↗

Analysis and correction of errors in nanoscale particle tracking using the Single-pixel interior filling function (SPIFF) algorithm

Particle tracking, which is an essential tool in many fields of scientific research, uses algorithms that retrieve the centroid of tracked particles with sub-pixel accuracy. However, images in which the particles occupy a small number of pixels on the detector, are in close proximity to other particles or suffer from background noise, show a systematic error in which the particle sub-pixel positions are biased towards the center of the pixel. This “pixel locking” effect greatly reduces particle tracking accuracy. In this report, we demonstrate the severity of these errors by tracking experimental (and simulated) imaging data of optically trapped silver nanoparticles and single fluorescent proteins. We show that errors in interparticle separation, angle and mean square displacement are significantly reduced by applying the corrective Single-Pixel Interior Filling Function (SPIFF) algorithm. Our work demonstrates the potential ubiquity of such errors and the general applicability of SPIFF correction to many experimental fields.

Science & Technology - Other Topics↗

Accuracy of electromagnetic tracking with a prototype field generator in an interventional OR setting

Purpose: The authors have studied the accuracy and robustness of a prototype electromagnetic window field generator (WFG) in an interventional radiology suite with a robotic C-arm. The overall purpose is the development of guidance systems combining real-time imaging with tracking of flexible instruments for bronchoscopy, laparoscopic ultrasound, endoluminal surgery, endovascular therapy, and spinal surgery. Methods: The WFG has a torus shape, which facilitates x-ray imaging through its centre. The authors compared the performance of the WFG to that of a standard field generator (SFG) under the influence of the C-arm. Both accuracy and robustness measurements were performed with the C-arm in different positions and poses. Results: The system was deemed robust for both field generators, but the accuracy was notably influenced as the C-arm was moved into the electromagnetic field. The SFG provided a smaller root-mean-square position error but was more influenced by the C-arm than the WFG. The WFG also produced smaller maximum and variance of the error. Conclusions: Electromagnetic (EM) tracking with the new WFG during C-arm based fluoroscopy guidance seems to be a step forward, and with a correction scheme implemented it should be feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-404: Dosimetric Advantages of Flattening Free Beams to Prone Accelerated Partial Breast Irradiation

Purpose: Prone accelerated partial breast irradiation (APBI) results in dose reduction to the heart and lung. Flattening filter free beams (FFF) reduce out of field dose due to the reduced scatter from the removal of the flattening filter and reduce the buildup region. The aim of this work is to evaluate the dosimetric advantages of FFF beams to prone APBI target coverage and reduction in dose to organs at risk. Methods: Fifteen clinical prone APBI cases using flattened photon beams were retrospectively re-planned in Eclipse-TPS using FFF beams. FFF plans were designed to provide equivalent target coverage with similar hotspots using the same field arrangements, resulting in comparable target DVHs. Both plans were transferred to a prone breast phantom and delivered on Varian-Edge-Linac. GafChromic-film was placed in the coronal plane of the phantom, partially overlapping the treatment field and extending into OARs to compare dose profiles from both plans. Results: FFF plans were comparable to the clinical plans with maximum doses of (108.3±2.3)% and (109.2±2.4)% and mean doses of (104.5±1.0)% and (104.6±1.2)%, respectively. Similar mean dose doses to the heart and contralateral lungs were observed from both plans, whereas the mean dose to the contra-lateral breast was (2.79±1.18) cGy and (2.86±1.40) cGy for FFF and clinical plans respectively. However for both plans the error between calculated and measured doses at 4 cm from the field edge was 10%. Conclusion: The results showed that FFF beams in prone APBI provide dosimetrically equivalent target coverage and improved coverage in superficial target due to softer energy spectra. Film analysis showed that the TPS underestimates dose outside field edges for both cases. The FFF measured plans showed less dose outside the beam that might reduce the probability of secondary cancers in the contralateral breast.

60 APPLIED LIFE SCIENCES↗

On-Board Imaging Validation of Optically Guided Stereotactic Radiosurgery Positioning System for Conventionally Fractionated Radiotherapy for Paranasal Sinus and Skull Base Cancer

Purpose: To evaluate the positioning accuracy of an optical positioning system for stereotactic radiosurgery in a pilot experience of optically guided, conventionally fractionated, radiotherapy for paranasal sinus and skull base tumors. Methods and Materials: Before each daily radiotherapy session, the positioning of 28 patients was set up using an optical positioning system. After this initial setup, the patients underwent standard on-board imaging that included daily orthogonal kilovoltage images and weekly cone beam computed tomography scans. Daily translational shifts were made after comparing the on-board images with the treatment planning computed tomography scans. These daily translational shifts represented the daily positional error in the optical tracking system and were recorded during the treatment course. For 13 patients treated with smaller fields, a three-degree of freedom (3DOF) head positioner was used for more accurate setup. Results: The mean positional error for the optically guided system in patients with and without the 3DOF head positioner was 1.4 {+-} 1.1 mm and 3.9 {+-} 1.6 mm, respectively (p <.0001). The mean positional error drifted 0.11 mm/wk upward during the treatment course for patients using the 3DOF head positioner (p = .057). No positional drift was observed in the patients without the 3DOF head positioner. Conclusion: Our initial clinical experience with optically guided head-and-neck fractionated radiotherapy was promising and demonstrated clinical feasibility. The optically guided setup was especially useful when used in conjunction with the 3DOF head positioner and when it was recalibrated to the shifts using the weekly portal images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Geometric and dosimetric accuracy of dynamic tumor-tracking conformal arc irradiation with a gimbaled x-ray head

Purpose: The Vero4DRT system has the capability for dynamic tumor-tracking (DTT) stereotactic irradiation using a unique gimbaled x-ray head. The purposes of this study were to develop DTT conformal arc irradiation and to estimate its geometric and dosimetric accuracy. Methods: The gimbaled x-ray head, supported on an O-ring gantry, was moved in the pan and tilt directions during O-ring gantry rotation. To evaluate the mechanical accuracy, the gimbaled x-ray head was moved during the gantry rotating according to input command signals without a target tracking, and a machine log analysis was performed. The difference between a command and a measured position was calculated as mechanical error. To evaluate beam-positioning accuracy, a moving phantom, which had a steel ball fixed at the center, was driven based on a sinusoidal wave (amplitude [A]: 20 mm, time period [T]: 4 s), a patient breathing motion with a regular pattern (A: 16 mm, average T: 4.5 s), and an irregular pattern (A: 7.2–23.0 mm, T: 2.3–10.0 s), and irradiated with DTT during gantry rotation. The beam-positioning error was evaluated as the difference between the centroid position of the irradiated field and the steel ball on images from an electronic portal imaging device. For dosimetric accuracy, dose distributions in static and moving targets were evaluated with DTT conformal arc irradiation. Results: The root mean squares (RMSs) of the mechanical error were up to 0.11 mm for pan motion and up to 0.14 mm for tilt motion. The RMSs of the beam-positioning error were within 0.23 mm for each pattern. The dose distribution in a moving phantom with tracking arc irradiation was in good agreement with that in static conditions. Conclusions: The gimbal positional accuracy was not degraded by gantry motion. As in the case of a fixed port, the Vero4DRT system showed adequate accuracy of DTT conformal arc irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Model of Procedure Usage – Results from a Qualitative Study to Inform Design of Computer-Based Procedures

The nuclear industry is constantly trying to find ways to decrease the human error rate, especially the human errors associated with procedure use. As a step toward the goal of improving procedure use performance, researchers, together with the nuclear industry, have been looking at replacing the current paper-based procedures with computer-based procedure systems. The concept of computer-based procedures is not new by any means; however most research has focused on procedures used in the main control room. Procedures reviewed in these efforts are mainly emergency operating procedures and normal operating procedures. Based on lessons learned for these previous efforts we are now exploring a more unknown application for computer based procedures - field procedures, i.e. procedures used by nuclear equipment operators and maintenance technicians. The Idaho National Laboratory, the Institute for Energy Technology, and participants from the U.S. commercial nuclear industry are collaborating in an applied research effort with the objective of developing requirements and specifications for a computer-based procedure system to be used by field operators. The goal is to identify the types of human errors that can be mitigated by using computer-based procedures and how to best design the computer-based procedures to do this. The underlying philosophy in the research effort is “Stop – Start – Continue”, i.e. what features from the use of paper-based procedures should we not incorporate (Stop), what should we keep (Continue), and what new features or work processes should be added (Start). One step in identifying the Stop – Start – Continue was to conduct a baseline study where affordances related to the current usage of paper-based procedures were identified. The purpose of the study was to develop a model of paper based procedure use which will help to identify desirable features for computer based procedure prototypes. Affordances such as note taking, markups, sharing procedures between fellow coworkers, the use of multiple procedures at once, etc. were considered. The model describes which affordances associated with paper based procedures should be transferred to computer-based procedures as well as what features should not be incorporated. The model also provides a means to identify what new features not present in paper based procedures need to be added to the computer-based procedures to further enhance performance. The next step is to use the requirements and specifications to develop concepts and prototypes of computer-based procedures. User tests and other data collection efforts will be conducted to ensure that the real issues with field procedures and their usage are being addressed and solved in the best manner possible. This paper describes the baseline study, the construction of the model of procedure use, and the requirements and specifications for computer-based procedures that were developed based on the model. It also addresses how the model and the insights gained from it were used to develop concepts and prototypes for computer based procedures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data clustering for the high-resolution alignment of microstructure and strain fields

The emergence of small-scale deformation mapping by a combination of scanning electron microscopy and digital image correlation (SEM-DIC) has enabled full-field investigations into the complex roles of microstructure on microscale deformation mechanisms. However, these investigations are hindered by errors in alignment between the microstructure data, generally acquired by electron backscatter diffraction (EBSD), and the microscale strain data obtained by SEM-DIC. Distortions, stitching artifacts, and spatial resolution differences between microstructure and strain fields can lead to misalignments on the order of μms. This alignment uncertainty introduces error into microstructure-strain localization analyses and precludes the examination of deformation mechanisms near grain boundaries. To improve alignment between EBSD-obtained grain boundaries and SEM-DIC strain data, an approach was created wherein a mantle was first established around the EBSD-acquired grain boundaries. Strain data was then clustered within this mantle using a k-means algorithm to identify grain boundary strain localization, and these boundary points were fit to obtain a continuous curve for each individual boundary. Clustered point outliers, such as those due to grain boundary-local dislocation slip, were statistically identified by using an absolute error threshold and removed from the grain boundary fit. The ending identification of grain boundaries in the microscale strain data is significantly improved from EBSD-identified boundaries.

36 MATERIALS SCIENCE↗

Exploring the Early Lightning Notification of an Electric Field Mill at the Savannah River Site

At the Savannah River Site (SRS), employees receive automated broadcast notification about lightning only after three strikes have already occurred near the site boundary. To increase employee safety, it is preferential to give employees lead time before lightning strikes occur. We compared measurements from an on-site electric field mill to lightning detection data from the National Lightning Detection Network and the Geostationary Lightning Mapper. Using a difference threshold, we determined that the electric field mill provided a lead time greater than 6 minutes for 95% of lightning events from 2009-2020, with an average lead time of 56 minutes. Detection of events were limited to a 7-mile radius around the field mill. We also identified that the field mill threshold generated many false detections not clearly identified. False detections and detections from only precipitation can be reduced by using a second threshold without creating too many missed detections (Type II errors). The two thresholds used together provide the best information about rapidly changing electric fields and aid in advanced detection necessary to improve the lightning warning system used at SRS.

42 ENGINEERING↗

Analysis of Integrated Vapor Transport Biases

Abstract High-fidelity analyses and forecasts of integrated vapor transport (VT) are central to the study of Earth’s hydrological cycle as well as high-impact phenomena such as monsoons and atmospheric rivers. The impact of the in-line analysis correction-based additive inflation (ACAI) on IVT biases and forecast errors is examined within the Navy Earth System Prediction Capability (Navy ESPC) global coupled system. The ACAI technique uses atmospheric analysis corrections from the data assimilation system to approximate model bias and as a representation of stochastic model error to simultaneously reduce systematic and random errors and improve ensemble performance. ACAI reduces the global average magnitude of the 7- and 14-day IVT bias by 16%–17% during Northern Hemisphere summer, reaching 70% reductions in some tropical regions. The global average IVT bias reduction is similar to the bias reduction for low-level wind speed bias and considerably smaller than the bias reduction in total precipitable water. The localized regions where ACAI increases IVT bias occur where the control IVT biases change sign and structure with increasing forecast lead time, such as the South Asian monsoon region. Substituting analyzed wind or moisture fields for the forecast fields when calculating the forecast IVT confirms that, on average, wind errors dominate the IVT error calculation in the tropics, although wind and moisture error contributions are comparable in the extratropics. The existence of regions where using either analyzed winds or analyzed moisture increases IVT bias or mean absolute error reveals areas with compensating errors.

Reynolds, Carolyn A.↗

Evaluation of an active magnetic resonance tracking system for interstitial brachytherapy

Purpose: In gynecologic cancers, magnetic resonance (MR) imaging is the modality of choice for visualizing tumors and their surroundings because of superior soft-tissue contrast. Real-time MR guidance of catheter placement in interstitial brachytherapy facilitates target coverage, and would be further improved by providing intraprocedural estimates of dosimetric coverage. A major obstacle to intraprocedural dosimetry is the time needed for catheter trajectory reconstruction. Herein the authors evaluate an active MR tracking (MRTR) system which provides rapid catheter tip localization and trajectory reconstruction. The authors assess the reliability and spatial accuracy of the MRTR system in comparison to standard catheter digitization using magnetic resonance imaging (MRI) and CT. Methods: The MRTR system includes a stylet with microcoils mounted on its shaft, which can be inserted into brachytherapy catheters and tracked by a dedicated MRTR sequence. Catheter tip localization errors of the MRTR system and their dependence on catheter locations and orientation inside the MR scanner were quantified with a water phantom. The distances between the tracked tip positions of the MRTR stylet and the predefined ground-truth tip positions were calculated for measurements performed at seven locations and with nine orientations. To evaluate catheter trajectory reconstruction, fifteen brachytherapy catheters were placed into a gel phantom with an embedded catheter fixation framework, with parallel or crossed paths. The MRTR stylet was then inserted sequentially into each catheter. During the removal of the MRTR stylet from within each catheter, a MRTR measurement was performed at 40 Hz to acquire the instantaneous stylet tip position, resulting in a series of three-dimensional (3D) positions along the catheter’s trajectory. A 3D polynomial curve was fit to the tracked positions for each catheter, and equally spaced dwell points were then generated along the curve. High-resolution 3D MRI of the phantom was performed followed by catheter digitization based on the catheter’s imaging artifacts. The catheter trajectory error was characterized in terms of the mean distance between corresponding dwell points in MRTR-generated catheter trajectory and MRI-based catheter digitization. The MRTR-based catheter trajectory reconstruction process was also performed on three gynecologic cancer patients, and then compared with catheter digitization based on MRI and CT. Results: The catheter tip localization error increased as the MRTR stylet moved further off-center and as the stylet’s orientation deviated from the main magnetic field direction. Fifteen catheters’ trajectories were reconstructed by MRTR. Compared with MRI-based digitization, the mean 3D error of MRTR-generated trajectories was 1.5 ± 0.5 mm with an in-plane error of 0.7 ± 0.2 mm and a tip error of 1.7 ± 0.5 mm. MRTR resolved ambiguity in catheter assignment due to crossed catheter paths, which is a common problem in image-based catheter digitization. In the patient studies, the MRTR-generated catheter trajectory was consistent with digitization based on both MRI and CT. Conclusions: The MRTR system provides accurate catheter tip localization and trajectory reconstruction in the MR environment. Relative to the image-based methods, it improves the speed, safety, and reliability of the catheter trajectory reconstruction in interstitial brachytherapy. MRTR may enable in-procedural dosimetric evaluation of implant target coverage.

60 APPLIED LIFE SCIENCES↗

Prediction of Alpha-Particle-Immune Gate-All-Around Field-Effect Transistors (GAA-FET) Based SRAM Design

Alpha particles are known to be a major source of particles creating soft errors in semiconductor devices, such as content flipping in Static Random-Access Memory (SRAM). Recent advancements in transistor nodes have led to the introduction of Gate-All-Around Field Effect Transistors (GAA-FETs), which have better gate control, thus better electrostatics. Moreover, the introduction of bottom dielectric isolation (BDI) eliminates substrate leakage and thus is expected to enhance its radiation hardness. It is thus important to explore if one can design an SRAM that is completely radiation-hard to alpha particles. In this paper, using 3D Technology Computer-Aided-Design (TCAD) simulations, we show that it is possible to design an SRAM using GAA-FET technology so that it is immune to single alpha particle radiation error. In other words, with the design, there will be no single-event upset (SEU) due to alpha particles. We first use ab initio calculations in PHITS to show that there is a maximum linear energy transfer (LET), LET max , for the alpha particle in Si and Si x Ge 1-x . Based on that, by de signing a sub-7nm GAA-FET-based SRAM with BDI, we show that the SRAM does not flip even if the particle strike is in the worst-case scenario for LET > LET max .

42 ENGINEERING↗