Search NASA⌕ Search

SEARCH · Search NASA

Results for “error reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Galerkin v. discrete-optimal projection in nonlinear model reduction

Discrete-optimal model-reduction techniques such as the Gauss{Newton with Approximated Tensors (GNAT) method have shown promise, as they have generated stable, accurate solutions for large-scale turbulent, compressible ow problems where standard Galerkin techniques have failed. However, there has been limited comparative analysis of the two approaches. This is due in part to difficulties arising from the fact that Galerkin techniques perform projection at the time-continuous level, while discrete-optimal techniques do so at the time-discrete level. This work provides a detailed theoretical and experimental comparison of the two techniques for two common classes of time integrators: linear multistep schemes and Runge{Kutta schemes. We present a number of new ndings, including conditions under which the discrete-optimal ROM has a time-continuous representation, conditions under which the two techniques are equivalent, and time-discrete error bounds for the two approaches. Perhaps most surprisingly, we demonstrate both theoretically and experimentally that decreasing the time step does not necessarily decrease the error for the discrete-optimal ROM; instead, the time step should be `matched' to the spectral content of the reduced basis. In numerical experiments carried out on a turbulent compressible- ow problem with over one million unknowns, we show that increasing the time step to an intermediate value decreases both the error and the simulation time of the discrete-optimal reduced-order model by an order of magnitude.

CFD↗

U.S. NO₂ trends (2005–2013): EPA air quality system (AQS) data versus improved observations from the Ozone Monitoring Instrument (OMI)

Emissions of nitrogen oxides (NO x ) and, subsequently, atmospheric levels of nitrogen dioxide (NO₂) have decreased over the U.S. due to a combination of environmental policies and technological change. Consequently, NO₂ levels have decreased by 30–40% in the last decade. We quantify NO₂ trends (2005–2013) over the U.S. using surface measurements from the U.S. Environmental Protection Agency (EPA) Air Quality System (AQS) and an improved tropospheric NO₂ vertical column density (VCD) data product from the Ozone Monitoring Instrument (OMI) on the Aura satellite.We demonstrate that the current OMI NO₂ algorithm is of sufficient maturity to allow a favorable correspondence of trends and variations in OMI and AQS data. Our trend model accounts for the non-linear dependence of NO₂ concentration on emissions associated with the seasonal variation of the chemical lifetime, including the change in the amplitude of the seasonal cycle associated with the significant change in NO x emissions that occurred over the last decade. The direct relationship between observations and emissions becomes more robust when one accounts for these non-linear dependencies. We improve the OMI NO₂ standard retrieval algorithm and, subsequently, the data product by using monthly vertical concentration profiles, a required algorithm input, from a high-resolution chemistry and transport model (CTM) simulation with varying emissions (2005-2013). The impact of neglecting the time-dependence of the profiles leads to errors in trend estimation, particularly in regions where emissions have changed substantially. For example, trends calculated from retrievals based on time-dependent profiles offer 18% more instances of significant trends and up to 15% larger total NO₂ reduction versus the results based on profiles for 2005. Using a CTM, we explore the theoretical relation of the trends estimated from NO₂ VCDs to those estimated from ground-level concentrations. The model-simulated trends in VCDs strongly correlate with those estimated from surface concentrations (r = 0.83, N = 355). We then explore the observed correspondence of trends estimated from OMI and AQS data. We find a significant, but slightly weaker, correspondence (i.e., r = 0.68, N = 208) than predicted by the model and discuss some of the important factors affecting the relationship, including known problems (e.g., NO z interferents) associated with the AQS data. This significant correspondence gives confidence in trend and surface concentration estimates from OMI VCDs for locations, such as the majority of the U.S. and globe, that are not covered by surface monitoring networks. Using our improved trend model and our enhanced OMI data product, we find that both OMI and AQS data show substantial downward trends from 2005 to 2013, with an average reduction of 38% for each over the U.S. The annual reduction rates inferred from OMI and AQS measurements are larger (–4.8 ± 1.9%/yr, –3.7 ± 1.5%/yr) from 2005 to 2008 than 2010 to 2013 (–1.2 ± 1.2%/yr, –2.1 ± 1.4%/yr). We quantify NO₂ trends for major U.S. cities and power plants; the latter suggest larger negative trend (–4.0 ± 1.5%/yr) between 2005 and 2008 and smaller or insignificant changes (–0.5 ± 1.2%/yr) during 2010-2013.

54 ENVIRONMENTAL SCIENCES↗

Mesoscale informed parameter estimation through machine learning: A case-study in fracture modeling

Scale bridging is a critical need in computational sciences, where the modeling community has developed accurate physics models from first principles, of processes at lower length and time scales that influence the behavior at the higher scales of interest. However, it is not computationally feasible to incorporate all of the lower length scale physics directly into upscaled models. This is an area where machine learning has shown promise in building emulators of the lower length scale models, which incur a mere fraction of the computational cost of the original higher fidelity models. We demonstrate the use of machine learning using an example in materials science estimating continuum scale parameters by emulating, with uncertainties, complicated mesoscale physics. Additionally, we describe a new framework to emulate the fine scale physics, especially in the presence of microstructures, using machine learning, and showcase its usefulness by providing an example from modeling fracture propagation. Our approach can be thought of as a data-driven dimension reduction technique that yields probabilistic emulators. Our results show well-calibrated predictions for the quantities of interests in a low-strain simulation of fracture propagation at the mesoscale level. Furthermore, on average, we achieve ~10% relative errors on time-varying quantities like total damage and maximum stresses. Successfully replicating mesoscale scale physics within the continuum models is a crucial step towards predictive capability in multi-scale problems.

36 MATERIALS SCIENCE↗

Modeling injection-induced fault slip using long short-term memory networks

Stress changes due to changes in fluid pressure and temperature in a faulted formation may lead to the opening/shearing of the fault. This can be due to subsurface (geo)engineering activities such as fluid injections and geologic disposal of nuclear waste. Such activities are expected to rise in the future making it necessary to assess their short- and long-term safety. Here, a new machine learning (ML) approach to model pore pressure and fault displacements in response to high-pressure fluid injection cycles is developed. The focus is on fault behavior near the injection borehole. To capture the temporal dependencies in the data, long short-term memory (LSTM) networks are utilized. To prevent error accumulation within the forecast window, four critical measures to train a robust LSTM model for predicting fault response are highlighted: (i) setting an appropriate value of LSTM lag, (ii) calibrating the LSTM cell dimension, (iii) learning rate reduction during weight optimization, and (iv) not adopting an independent injection cycle as a validation set. Several numerical experiments were conducted, which demonstrated that the ML model can capture peaks in pressure and associated fault displacement that accompany an increase in fluid injection. The model also captured the decay in pressure and displacement during the injection shut-in period. Further, the ability of an ML model to highlight key changes in fault hydromechanical activation processes was investigated, which shows that ML can be used to monitor risk of fault activation and leakage during high pressure fluid injections.

58 GEOSCIENCES↗

Open Circuit Potential Method for Thermodynamic Hydricity Measurements of Metal Hydrides

Metal hydrides are prevalent in many catalytic reactions, and thermodynamic hydricity has emerged as a useful parameter for understanding and predicting key hydride transfer steps with these intermediates. An open circuit potentiometry method for determining the hydricity of metal hydrides with a single thermodynamic parameter is reported. The open circuit potential (OCP) of a solution containing a metal hydride and its conjugate hydride acceptor, along with a conjugate acid/base pair, is coupled with known values for the acid pK a and H + /H – reduction potential to determine the hydricity. Here, the reliability of the method was established by using potentiometry to obtain the hydricity of three hydride complexes with varying supporting ligands and transition metal elements in acetonitrile solvent, all within error of previously reported values. Advantages and drawbacks of this method are discussed, and a recommended workflow for practitioners is introduced.

Anions↗

RMP Enhanced Transport and Rotation Screening in DIII-D Simulations

The application of resonant magnetic perturbations (RMP) to DIII-D plasmas at low collisionality has achieved ELM suppression, primarily due to a pedestal density reduction. The mechanism of the enhanced particle transport is investigated in 3D MHD simulations with the NIMROD code. The simulations apply realistic vacuum fields from the DIII-D I-coils, C-coils and measure intrinsic error fields to an EFIT reconstructed DIII-D equilibrium, and allow the plasma to respond to the applied fields while the fields are fixed at the boundary, which lies in the vacuum region. A non-rotating plasma amplifies the resonant components of the applied fields by factors of 2-5. The poloidal velocity forms E x B convection cells crossing the separatrix, which push particles into the vacuum region and reduce the pedestal density. Low toroidal rotation at the separatrix reduces the resonant field amplitudes, but does not strongly affect the particle pumpout. At higher separatrix rotation, the poloidal E x B velocity is reduced by half, while the enhanced particle transport is entirely eliminated. A high collisionality DIII-D equilibrium with an experimentally measured rotation profile serves as the starting point for a simulation with odd parity I-coil fields that can ultimately be compared with experimental results. All of the NIMROD results are compared with analytic error field theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of SNS Beamline Shielding Configurations using MCNPX Accelerated by ADVANTG

Shielding analyses for the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory pose significant computational challenges, including highly anisotropic high-energy sources, a combination of deep penetration shielding and an unshielded beamline, and a desire to obtain well-converged nearly global solutions for mapping of predicted radiation fields. The majority of these analyses have been performed using MCNPX with manually generated variance reduction parameters (source biasing and cell-based splitting and Russian roulette) that were largely based on the analyst's insight into the problem specifics. Development of the variance reduction parameters required extensive analyst time, and was often tailored to specific portions of the model phase space. We previously applied a developmental version of the ADVANTG code to an SNS beamline study to perform a hybrid deterministic/Monte Carlo analysis and showed that we could obtain nearly global Monte Carlo solutions with essentially uniform relative errors for mesh tallies that cover extensive portions of the model with typical voxel spacing of a few centimeters. The use of weight window maps and consistent biased sources produced using the FW-CADIS methodology in ADVANTG allowed us to obtain these solutions using substantially less computer time than the previous cell-based splitting approach. While those results were promising, the process of using the developmental version of ADVANTG was somewhat laborious, requiring user-developed Python scripts to drive much of the analysis sequence. In addition, limitations imposed by the size of weight-window files in MCNPX necessitated the use of relatively coarse spatial and energy discretization for the deterministic Denovo calculations that we used to generate the variance reduction parameters. We recently applied the production version of ADVANTG to this beamline analysis, which substantially streamlined the analysis process. We also tested importance function collapsing (in space and energy) capabilities in ADVANTG. These changes, along with the support for parallel Denovo calculations using the current version of ADVANTG, give us the capability to improve the fidelity of the deterministic portion of the hybrid analysis sequence, obtain improved weight-window maps, and reduce both the analyst and computational time required for the analysis process.

43 PARTICLE ACCELERATORS↗

SU-G-IeP3-05: Effects of Image Receptor Technology and Dose Reduction Software On Radiation Dose Estimates for Fluoroscopically-Guided Interventional (FGI) Procedures

Purpose: To investigate the effects of image receptor technology and dose reduction software on radiation dose estimates for most frequently performed fluoroscopically-guided interventional (FGI) procedures at a tertiary health care center. Methods: IRB approval was obtained for retrospective analysis of FGI procedures performed in the interventional radiology suites between January-2011 and December-2015. This included procedures performed using image-intensifier (II) based systems which were subsequently replaced, flat-panel-detector (FPD) based systems which were later upgraded with ClarityIQ dose reduction software (Philips Healthcare) and relatively new FPD system already equipped with ClarityIQ. Post procedure, technologists entered system-reported cumulative air kerma (CAK) and kerma-area product (KAP; only KAP for II based systems) in RIS; these values were analyzed. Data pre-processing included correcting typographical errors and cross-verifying CAK and KAP. The most frequent high and low dose FGI procedures were identified and corresponding CAK and KAP values were compared. Results: Out of 27,251 procedures within this time period, most frequent high and low dose procedures were chemo/immuno-embolization (n=1967) and abscess drainage (n=1821). Mean KAP for embolization and abscess drainage procedures were 260,657, 310,304 and 94,908 mGycm{sup 2}, and 14,497, 15,040 and 6307 mGycm{sup 2} using II-, FPD- and FPD with ClarityIQ- based systems, respectively. Statistically significant differences were observed in KAP values for embolization procedures with respect to different systems but for abscess drainage procedures significant differences were only noted between systems with FPD and FPD with ClarityIQ (p<0.05). Mean CAK reduced significantly from 823 to 308 mGy and from 43 to 21 mGy for embolization and abscess drainage procedures, respectively, in transitioning to FPD systems with ClarityIQ (p<0.05). Conclusion: While transitioning from II- to FPD- based systems was not associated with dose reduction for the most frequently performed FGI procedures, substantial dose reduction was noted with relatively newer systems and dose reduction software.

60 APPLIED LIFE SCIENCES↗

Dosimetric Effect of Intrafraction Motion and Residual Setup Error for Hypofractionated Prostate Intensity-Modulated Radiotherapy With Online Cone Beam Computed Tomography Image Guidance

Purpose: To quantify the dosimetric effect and margins required to account for prostate intrafractional translation and residual setup error in a cone beam computed tomography (CBCT)-guided hypofractionated radiotherapy protocol. Methods and Materials: Prostate position after online correction was measured during dose delivery using simultaneous kV fluoroscopy and posttreatment CBCT in 572 fractions to 30 patients. We reconstructed the dose distribution to the clinical tumor volume (CTV) using a convolution of the static dose with a probability density function (PDF) based on the kV fluoroscopy, and we calculated the minimum dose received by 99% of the CTV (D{sub 99}). We compared reconstructed doses when the convolution was performed per beam, per patient, and when the PDF was created using posttreatment CBCT. We determined the minimum axis-specific margins to limit CTV D{sub 99} reduction to 1%. Results: For 3-mm margins, D{sub 99} reduction was {<=}5% for 29/30 patients. Using post-CBCT rather than localizations at treatment delivery exaggerated dosimetric effects by {approx}47%, while there was no such bias between the dose convolved with a beam-specific and patient-specific PDF. After eight fractions, final cumulative D{sub 99} could be predicted with a root mean square error of <1%. For 90% of patients, the required margins were {<=}2, 4, and 3 mm, with 70%, 40%, and 33% of patients requiring no right-left (RL), anteroposterior (AP), and superoinferior margins, respectively. Conclusions: For protocols with CBCT guidance, RL, AP, and SI margins of 2, 4, and 3 mm are sufficient to account for translational errors; however, the large variation in patient-specific margins suggests that adaptive management may be beneficial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combined iterative reconstruction and image-domain decomposition for dual energy CT using total-variation regularization

Purpose: Dual-energy CT (DECT) is being increasingly used for its capability of material decomposition and energy-selective imaging. A generic problem of DECT, however, is that the decomposition process is unstable in the sense that the relative magnitude of decomposed signals is reduced due to signal cancellation while the image noise is accumulating from the two CT images of independent scans. Direct image decomposition, therefore, leads to severe degradation of signal-to-noise ratio on the resultant images. Existing noise suppression techniques are typically implemented in DECT with the procedures of reconstruction and decomposition performed independently, which do not explore the statistical properties of decomposed images during the reconstruction for noise reduction. In this work, the authors propose an iterative approach that combines the reconstruction and the signal decomposition procedures to minimize the DECT image noise without noticeable loss of resolution. Methods: The proposed algorithm is formulated as an optimization problem, which balances the data fidelity and total variation of decomposed images in one framework, and the decomposition step is carried out iteratively together with reconstruction. The noise in the CT images from the proposed algorithm becomes well correlated even though the noise of the raw projections is independent on the two CT scans. Due to this feature, the proposed algorithm avoids noise accumulation during the decomposition process. The authors evaluate the method performance on noise suppression and spatial resolution using phantom studies and compare the algorithm with conventional denoising approaches as well as combined iterative reconstruction methods with different forms of regularization. Results: On the Catphan©600 phantom, the proposed method outperforms the existing denoising methods on preserving spatial resolution at the same level of noise suppression, i.e., a reduction of noise standard deviation by one order of magnitude. This improvement is mainly attributed to the high noise correlation in the CT images reconstructed by the proposed algorithm. Iterative reconstruction using different regularization, including quadratic orq-generalized Gaussian Markov random field regularization, achieves similar noise suppression from high noise correlation. However, the proposed TV regularization obtains a better edge preserving performance. Studies of electron density measurement also show that our method reduces the average estimation error from 9.5% to 7.1%. On the anthropomorphic head phantom, the proposed method suppresses the noise standard deviation of the decomposed images by a factor of ∼14 without blurring the fine structures in the sinus area. Conclusions: The authors propose a practical method for DECT imaging reconstruction, which combines the image reconstruction and material decomposition into one optimization framework. Compared to the existing approaches, our method achieves a superior performance on DECT imaging with respect to decomposition accuracy, noise reduction, and spatial resolution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling electron beam irradiation of methane

We built a chemical kinetic model for the electron beam irradiation of methane and report simulation results with dose rates ranging from 2 to 200 kGy s -1 at 298 K and 1 atm pressure. The model contains 92 species and 778 gas-phase reactions. We report the time evolution of concentrations of stable products (including H 2 , C 2 H 6 , C 3 H 8 , C 2 H 4 , C 3 H 6 , C 4 H 10 , C 2 H 2 , and C 3 H 4 ) as well as some radicals and ions. Here we discuss how yields of products depend on dose rate and how they change during the course of irradiation. To understand the processes controlling product formation, we quantify the extent to which various reactions produce and destroy major products and the key radicals and ions. Normalized sensitivity coefficients are computed for the production of stable products to gain further insight into factors controlling product yields. We were able to reduce the mechanism to 63 species and 331 reactions while incurring less than 5% error in the final concentrations of stable products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimizing Collimator Margins for Isotoxically Dose-Escalated Conformal Radiation Therapy of Non-Small Cell Lung Cancer

Purpose: Isotoxic dose escalation schedules such as IDEAL-CRT [isotoxic dose escalation and acceleration in lung cancer chemoradiation therapy] (ISRCTN12155469) individualize doses prescribed to lung tumors, generating a fixed modeled risk of radiation pneumonitis. Because the beam penumbra is broadened in lung, the choice of collimator margin is an important element of the optimization of isotoxic conformal radiation therapy for lung cancer. Methods and Materials: Twelve patients with stage I-III non-small cell lung cancer (NSCLC) were replanned retrospectively using a range of collimator margins. For each plan, the prescribed dose was calculated according to the IDEAL-CRT isotoxic prescription method, and the absolute dose (D{sub 99}) delivered to 99% of the planning target volume (PTV) was determined. Results: Reducing the multileaf collimator margin from the widely used 7 mm to a value of 2 mm produced gains of 2.1 to 15.6 Gy in absolute PTV D{sub 99}, with a mean gain ± 1 standard error of the mean of 6.2 ± 1.1 Gy (2-sided P<.001). Conclusions: For NSCLC patients treated with conformal radiation therapy and an isotoxic dose prescription, absolute doses in the PTV may be increased by using smaller collimator margins, reductions in relative coverage being offset by increases in prescribed dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimal Submodule Capacitor Sizing for Modular Multilevel Converters with Common Mode Voltage Injection and Circulating Current Control

Abstract - Modular multilevel converters (MMCs), with the filterless and transformer-less features, are considered as a promising topology for high-efficiency medium voltage (MV) high voltage (HV) drive systems. However, at low frequencies (< 30 Hz), a large current ripple flowing through the capacitors of each submodule will cause significant capacitor voltage fluctuation. This paper proposes an optimal submodule capacitor selection based on the common mode voltage injection. The proposed sizing model includes two functions: a) accurately estimating the capacitor voltage ripple based on the drive system parameters; and b) identifying the minimum capacitance of the submodule capacitors based on the allowed maximum capacitor voltage fluctuations. Simulation and hardware-in-the-loop (HIL) test results show that the error between the actual and estimated values of the voltage fluctuation is within 3% using the proposed model.

Capacitor Sizing↗

NISQ+: Boosting quantum computing power by approximating quantum error correction

Quantum computers are growing in size, and design decisions are being made now that attempt to squeeze more computation out of these machines. In this spirit, we design a method to boost the computational power of near-term quantum computers by adapting protocols used in quantum error correction to implement "Approximate Quantum Error Correction (AQEC)." By approximating fully-fledged error correction mechanisms, we can increase the compute volume (qubits × gates, or "Simple Quantum Volume (SQV)") of near-term machines. The crux of our design is a fast hardware decoder that can approximately decode detected error syndromes rapidly. Specifically, we demonstrate a proof-of-concept that approximate error decoding can be accomplished online in near-term quantum systems by designing and implementing a novel algorithm in Single-Flux Quantum (SFQ) superconducting logic technology. This avoids a critical decoding backlog, hidden in all offline decoding schemes, that leads to idle time exponential in the number of T gates in a program. Our design utilizes one SFQ processing module per physical qubit. Employing state-of-the-art SFQ synthesis tools, we show that the circuit area, power, and latency are within the constraints of contemporary quantum system designs. Under pure dephasing error models, the proposed accelerator and AQEC solution is able to expand SQV by factors between 3,402 and 11,163 on expected near-term machines. The decoder achieves a 5% accuracy-threshold and pseudo-thresholds of ~ 5%,4.75%,4.5%, and 3.5% physical error-rates for code distances 3,5,7, and 9. Decoding solutions are achieved in a maximum of ~20 nanoseconds on the largest code distances studied. By avoiding the exponential idle time in offline decoders, we achieve a 10x reduction in required code distances to achieve the same logical performance as alternative designs.

97 MATHEMATICS AND COMPUTING↗

Reducing beta functions in the NSLS-II long straight section for NEXT-III beamlines

The NSLS-II Experimental Tools III (NEXT-III) Project with the goal of building 8-12 new beamlines is ongoing. We were requested to explore the possibility of modifying the long straight section in Cell 26 to accommodate two new undulators for Advanced Nanoscale Imaging (ANI) Beamline and Tender X-ray Nanoprobe (TXN) Beamline. The scope of work includes: linear lattice matching; confirmation of the minimum ID gaps consistent with beam stay-clear limitations; calculation of the X-ray brightness; optimization of the dynamic aperture and momentum acceptance; multi-particle tracking to confirm the injection efficiency does not deteriorate significantly. The beam simulations have to be done using the most recent NSLS-II lattice model with all present insertion devices and realistic magnet errors, misalignments, and apertures. Originally two lattice options were considered for the assessment:1) with single -minimum beta functions and 2) NSLS-II with double-minimum beta functions. However, since the beamlines are not interested in the reduction of the horizontal beta function, just the vertical one, we decided to stop considering the single-minimum option because the current vertical beta is already low (3.3m) and further reducing it at the straight section center can increase it too much at the edge of a long ID, and limit the beam stay-clear. So, this report is focused on the double mini-beta scheme only.

43 PARTICLE ACCELERATORS↗

Lifting MGARD: Construction of (pre)wavelets on the interval using polynomial predictors of arbitrary order

MGARD (MultiGrid Adaptive Reduction of Data) is an algorithm for compressing and refactoring scientific data, based on the theory of multigrid methods. The core algorithm is built around stable multilevel decompositions of conforming piecewise linear $C^0$ finite element spaces, enabling accurate error control in various norms and derived quantities of interest. In this work, we extend this construction to arbitrary order Lagrange finite elements $\mathbb{Q}_p$, $p \geq 0$, and propose a reformulation of the algorithm as a lifting scheme with polynomial predictors of arbitrary order. Additionally, a new formulation using a compactly supported wavelet basis is discussed, and an explicit construction of the proposed wavelet transform for uniform dyadic grids is described.

Reshniak, Viktor [Oak Ridge National Laboratory (O↗

Case studies in bias reduction and inference for electronic health record data with selection bias and phenotype misclassification

Electronic health records (EHR) are not designed for population‐based research, but they provide easy and quick access to longitudinal health information for a large number of individuals. Many statistical methods have been proposed to account for selection bias, missing data, phenotyping errors, or other problems that arise in EHR data analysis. However, addressing multiple sources of bias simultaneously is challenging. We developed a methodological framework (R package, SAMBA ) for jointly handling both selection bias and phenotype misclassification in the EHR setting that leverages external data sources. These methods assume factors related to selection and misclassification are fully observed, but these factors may be poorly understood and partially observed in practice. As a follow‐up to the methodological work, we demonstrate how to apply these methods for two real‐world case studies, and we evaluate their performance. In both examples, we use individual patient‐level data collected through the University of Michigan Health System and various external population‐based data sources. In case study (a), we explore the impact of these methods on estimated associations between gender and cancer diagnosis. In case study (b), we compare corrected associations between previously identified genetic loci and age‐related macular degeneration with gold standard external summary estimates. These case studies illustrate how to utilize diverse auxiliary information to achieve less biased inference in EHR‐based research.

60 APPLIED LIFE SCIENCES↗

SU-E-J-183: Quantifying the Image Quality and Dose Reduction of Respiratory Triggered 4D Cone-Beam Computed Tomography with Patient- Measured Breathing

Purpose: Respiratory triggered four dimensional cone-beam computed tomography (RT 4D CBCT) is a novel technique that uses a patient's respiratory signal to drive the image acquisition with the goal of imaging dose reduction without degrading image quality. This work investigates image quality and dose using patient-measured respiratory signals for RT 4D CBCT simulations instead of synthetic sinusoidal signals used in previous work. Methods: Studies were performed that simulate a 4D CBCT image acquisition using both the novel RT 4D CBCT technique and a conventional 4D CBCT technique from a database of oversampled Rando phantom CBCT projections. A database containing 111 free breathing lung cancer patient respiratory signal files was used to create 111 RT 4D CBCT and 111 conventional 4D CBCT image datasets from realistic simulations of a 4D RT CBCT system. Each of these image datasets were compared to a ground truth dataset from which a root mean square error (RMSE) metric was calculated to quantify the degradation of image quality. The number of projections used in each simulation is counted and was assumed as a surrogate for imaging dose. Results: Based on 111 breathing traces, when comparing RT 4D CBCT with conventional 4D CBCT the average image quality was reduced by 7.6%. However, the average imaging dose reduction was 53% based on needing fewer projections (617 on average) than conventional 4D CBCT (1320 projections). Conclusion: The simulation studies using a wide range of patient breathing traces have demonstrated that the RT 4D CBCT method can potentially offer a substantial saving of imaging dose of 53% on average compared to conventional 4D CBCT in simulation studies with a minimal impact on image quality. A patent application (PCT/US2012/048693) has been filed which is related to this work.

60 APPLIED LIFE SCIENCES↗