At least 793 records · Page 44

Forecasting the Decay of Hybrid Perovskite Performance Using Optical Transmittance or Reflected Dark-Field Imaging

The practicality and economic viability of hybrid perovskite solar cells hinge on their operational lifetime, and methods for forecasting the performance of perovskites under different operational stresses are urgently needed. Here, we explore the evolution of material-level optoelectronic properties as MAPbI 3 degrades and discover universal behaviors where the carrier diffusion length (L D ) decays before quasi-Fermi-level splitting (ΔE F ), regardless of the specific stress protocol (oxygen, humidity, thermal stress, or a combination). We employ a machine learning greedy feature selection model that uses initially measured properties to predict the time it takes L D to decrease to 85% of its initial value with a prediction accuracy of 12.8%. This model reveals a strong correlation between the initial rate of transmittance change and the time until loss of transport. We translate this material-level finding to photovoltaic device-level forecasting by demonstrating that the rate of change of transmittance is equivalent to the rate of change of the spatial standard deviation of dark-field image intensity (i.e., scattered light intensity) collected in reflection mode (and thus applicable to devices with opaque contacts). Furthermore, this work demonstrates that transmittance and scattering methods are highly effective for accelerated material (and device) stability evaluation and forecasting.

14 SOLAR ENERGY↗

Assessment of task‐based performance from five clinical DBT systems using an anthropomorphic breast phantom

Purpose Digital breast tomosynthesis (DBT) is a limited‐angle tomographic breast imaging modality that can be used for breast cancer screening in conjunction with full‐field digital mammography (FFDM) or synthetic mammography (SM). Currently, there are five commercial DBT systems that have been approved by the U.S. FDA for breast cancer screening, all varying greatly in design and imaging protocol. Because the systems are different in technical specifications, there is a need for a quantitative approach for assessing them. In this study, the DBT systems are assessed using a novel methodology with an inkjet‐printed anthropomorphic phantom and four alternative forced choice (4AFC) study scheme. Method A breast phantom was fabricated using inkjet printing and parchment paper. The phantom contained 5‐mm spiculated masses fabricated with potassium iodide (KI)‐doped ink and microcalcifications (MCs) made with calcium hydroxyapatite. Images of the phantom were acquired on all five systems with DBT, FFDM, and SM modalities where available using beam settings under automatic exposure control. A 4AFC study was conducted to assess reader performance with each signal under each modality. Statistical analysis was performed on the data to determine proportion correct (PC), standard deviations, and levels of significance. Results For masses, overall detection was highest with DBT. The difference in PC was statistically significant between DBT and SM for most systems. A relationship was observed between increasing PC and greater gantry span. For MCs, performance was highest with DBT and FFDM compared to SM. The difference between PC of DBT and PC of SM was statistically significant for all manufacturers. Conclusions This methodology represents a novel approach for evaluating systems. This study is the first of its kind to use an inkjet‐printed anthropomorphic phantom with realistic signals to assess performance of clinical DBT imaging systems.

Ikejimba, Lynda C.↗

Spherical nanoindentation stress–strain curves

Although indentation experiments have long been used to measure the hardness and Young's modulus, the utility of this technique in analyzing the complete elastic–plastic response of materials under contact loading has only been realized in the past few years – mostly due to recent advances in testing equipment and analysis protocols. This paper provides a timely review of the recent progress made in this respect in extracting meaningful indentation stress–strain curves from the raw datasets measured in instrumented spherical nanoindentation experiments. These indentation stress–strain curves have produced highly reliable estimates of the indentation modulus and the indentation yield strength in the sample, as well as certain aspects of their post-yield behavior, and have been critically validated through numerical simulations using finite element models as well as direct in situ scanning electron microscopy (SEM) measurements on micro-pillars. Much of this recent progress was made possible through the introduction of a new measure of indentation strain and the development of new protocols to locate the effective zero-point of initial contact between the indenter and the sample in the measured datasets. As a result, this has led to an important key advance in this field where it is now possible to reliably identify and analyze the initial loading segment in the indentation experiments.

36 MATERIALS SCIENCE↗

Neutral-atom entanglement using adiabatic Rydberg dressing

Here we revisit the implementation of a two-qubit entangling gate, the Mølmer-Sørensen gate, using the adiabatic Rydberg dressing paradigm for neutral atoms as studied in [A. Mitra et al., Phys. Rev. A 101, 030301(R) (2020)]. We study the implementation of rapid adiabatic passage using a two-photon transition, which does not require the use of an ultraviolet laser, and can be implemented using only amplitude modulation of one field with all laser frequencies fixed. We find that entangling gate fidelities, comparable to the one-photon excitation, are achievable with the two-photon excitation. Moreover, we address how the adiabatic dressing protocol can be used to implement entangling gates outside the regime of a perfect Rydberg blockade. We show that, by using adiabatic dressing, we can achieve scaling of the gate fidelity set by the fundamental limits to entanglement generated by the Rydberg interactions while simultaneously retaining a limited population in the doubly excited Rydberg state. This allows for fast high-fidelity gates for atoms separated beyond the blockade radius.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-delayed entanglement from coherently coupled nonlinear cavities

The output fields of a pair of coherently coupled nonlinear optical cavities are found to exhibit strong optical entanglement. For sufficiently strong coupling time-delayed quantum correlations are observed providing a resource for quantum information protocols such as all-optical quantum memories. A straightforward experimental implementation applicable to whispering gallery mode resonators such as microtoroids is proposed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electroweak probes of ground state densities

Background: Elastic electron scattering has been used for decades to paint the most accurate picture of the proton distribution in atomic nuclei. This stands in stark contrast to the neutron distribution that is traditionally probed using hadronic reactions that are hindered by large uncertainties in the reaction mechanism. Spurred by new experimental developments, it is now possible to gain valuable insights into the neutron distribution using exclusively electroweak probes. Purpose: In this work, we aim to assess the information content and complementarity of the following three electroweak experiments in constraining the neutron distribution of atomic nuclei: (a) parity-violating elastic electron scattering, (b) coherent elastic neutrino-nucleus scattering, and (c) elastic electron scattering of unstable nuclei. Methods: Relativistic mean-field models informed by the properties of finite nuclei and neutron stars are used to compute ground state densities and form factors of a variety of nuclei. All the models follow the same fitting protocol, except for the assumed—and presently unknown—value of the neutron skin thickness of 208 Pb. This enables one to tune the density dependence of the symmetry energy without compromising the success in reproducing well known physical observables. Results: We found that the ongoing PREX-II and upcoming CREX campaigns at Jefferson Lab will play a vital role in constraining the weak form factor of xenon and argon, liquid noble gases that are used for the detection of both neutrinos and dark matter particles. Conclusions: Remarkable new advances in experimental physics have opened a new window into ground state densities of atomic nuclei using solely electroweak probes. The diversity and versatility of these experiments reveal powerful correlations that impose important nuclear structure constraints. In turn, these constraints provide quantitative theoretical uncertainties that are instrumental in searches for new physics and insights into the behavior of dense matter.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comment on 'Existence of long-lived isomeric states in naturally-occurring neutron-deficient Th isotopes'

In their article ''Existence of Long-Lived Isomeric States in Naturally-Occuring Neutron-Deficient Th Isotopes''[Phys. Rev. C 76, 021303 (2007)], Marinov et al. fail to demonstrate that basic mass spectrometric protocols, such as abundance sensitivity, linearity, and freedom from possible interferences, have been met. In particular, the claim that four isomeric states of Th have been discovered, using an inductively coupled plasma-sector field mass spectrometer (ICP-SFMS), with abundances from (1-10)x10{sup -11} relative to {sup 232}Th, cannot be accepted, given the known abundance sensitivities of other sector field mass spectrometers. Accelerator mass spectrometry is the only mass spectrometric methodology capable of measuring relative abundances of the magnitude claimed by Marinov et al.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Local Measurement of Tropospheric HO(x)

In March of 1992 a workshop sponsored by NASA and NSF was held at SRI International to assess the current ability to measure atmospheric OH and HO2. The measurement techniques reviewed during the workshop for detection of OH included five laser-induced fluorescence schemes, five laser-based adsorption techniques, and four non-laser methods. Six instruments or instrument concepts for HO2 detection, including chemical amplification, conversion to OH with subsequent OH detection, or direct spectroscopic detection of the HO2 were also discussed. The conclusions from the workshop identify several measurement techniques for OH and HO2 that are ready for field tests. These have the ability to measure the radicals with sufficient sensitivity and accuracy to form meaningful comparison with atmospheric model predictions. The workshop conclusions also include recommendations for informal and formal intercomparison protocols.

Crosley, David R.↗

Technical Note: Evaluation of a 160-mm/256-row CT scanner for whole-heart quantitative myocardial perfusion imaging

Purpose: The authors investigated the performance of a recently introduced 160-mm/256-row CT system for low dose quantitative myocardial perfusion (MP) imaging of the whole heart. This platform is equipped with a gantry capable of rotating at 280 ms per full cycle, a second generation of adaptive statistical iterative reconstruction (ASiR-V) to correct for image noise arising from low tube voltage potential/tube current dynamic scanning, and image reconstruction algorithms to tackle beam-hardening, cone-beam, and partial-scan effects. Methods: Phantom studies were performed to investigate the effectiveness of image noise and artifact reduction with a GE Healthcare Revolution CT system for three acquisition protocols used in quantitative CT MP imaging: 100, 120, and 140 kVp/25 mAs. The heart chambers of an anthropomorphic chest phantom were filled with iodinated contrast solution at different concentrations (contrast levels) to simulate the circulation of contrast through the heart in quantitative CT MP imaging. To evaluate beam-hardening correction, the phantom was scanned at each contrast level to measure the changes in CT number (in Hounsfield unit or HU) in the water-filled region surrounding the heart chambers with respect to baseline. To evaluate cone-beam artifact correction, differences in mean water HU between the central and peripheral slices were compared. Partial-scan artifact correction was evaluated from the fluctuation of mean water HU in successive partial scans. To evaluate image noise reduction, a small hollow region adjacent to the heart chambers was filled with diluted contrast, and contrast-to-noise ratio in the region before and after noise correction with ASiR-V was compared. The quality of MP maps acquired with the CT system was also evaluated in porcine CT MP studies. Myocardial infarct was induced in a farm pig from a transient occlusion of the distal left anterior descending (LAD) artery with a catheter-based interventional procedure. MP maps were generated from the dynamic contrast-enhanced (DCE) heart images taken at baseline and three weeks after the ischemic insult. Results: Their results showed that the phantom and animal images acquired with the CT platform were minimally affected by image noise and artifacts. For the beam-hardening phantom study, changes in water HU in the wall surrounding the heart chambers greatly reduced from >±30 to ≤ ± 5 HU at all kVp settings except one region at 100 kVp (7 HU). For the cone-beam phantom study, differences in mean water HU from the central slice were less than 5 HU at two peripheral slices with each 4 cm away from the central slice. These findings were reproducible in the pig DCE images at two peripheral slices that were 6 cm away from the central slice. For the partial-scan phantom study, standard deviations of the mean water HU in 10 successive partial scans were less than 5 HU at the central slice. Similar observations were made in the pig DCE images at two peripheral slices with each 6 cm away from the central slice. For the image noise phantom study, CNRs in the ASiR-V images were statistically higher (p < 0.05) than the non-ASiR-V images at all kVp settings. MP maps generated from the porcine DCE images were in excellent quality, with the ischemia in the LAD territory clearly seen in the three orthogonal views. Conclusions: The study demonstrates that this CT system can provide accurate and reproducible CT numbers during cardiac gated acquisitions across a wide axial field of view. This CT number fidelity will enable this imaging tool to assess contrast enhancement, potentially providing valuable added information beyond anatomic evaluation of coronary stenoses. Furthermore, their results collectively suggested that the 100 kVp/25 mAs protocol run on this CT system provides sufficient image accuracy at a low radiation dose (<3 mSv) for whole-heart quantitative CT MP imaging.

60 APPLIED LIFE SCIENCES↗

Sapphire substrate qubit-based detector for light dark matter search

Harnessing sub-eV energy excitations from light dark matter interaction with a target material is one of the challenges in exploring promising novel materials for dark matter searches. In polar materials like sapphire, dark matter interaction can excite sub-eV optical phonon modes. Furthermore, the anisotropy of sapphire crystal could provide a signature of daily modulation of the dark matter scattering rate, making it a promising target material. We plan to utilize superconducting qubits on a sapphire substrate to take advantage of the excitation of phonons, which scatter and further down-convert to lower-energy phonons. A good fraction of these phonons are expected to reach the qubit superconductor on the substrate and break Cooper pairs. Such a process can cause qubit decoherence, which can be measured using standard qubit readout protocol. In this talk, we describe our ongoing attempt to build such a prototype detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cooling a Mechanical Resonator with Nitrogen-Vacancy Centres Using a Room Temperature Excited State Spin-Strain Interaction

Cooling a mechanical resonator mode to a sub-thermal state has been a long-standing challenge in physics. This pursuit has recently found traction in the field of optomechanics in which a mechanical mode is coupled to an optical cavity. An alternate method is to couple the resonator to a well-controlled two-level system. Here we propose a protocol to dissipatively cool a room temperature mechanical resonator using a nitrogen-vacancy centre ensemble. The spin ensemble is coupled to the resonator through its orbitally-averaged excited state, which has a spin-strain interaction that has not been previously studied. We experimentally demonstrate that the spin-strain coupling in the excited state is 13.5 ± 0.5 times stronger than the ground state spin-strain coupling. Lastly, we then theoretically show that this interaction, combined with a high-density spin ensemble, enables the cooling of a mechanical resonator from room temperature to a fraction of its thermal phonon occupancy.

36 MATERIALS SCIENCE↗

Quantized resistance revealed at the criticality of the quantum anomalous Hall phase transitions

In multilayered magnetic topological insulator structures, magnetization reversal processes can drive topological phase transitions between quantum anomalous Hall, axion insulator, and normal insulator states. Here we report an examination of the critical behavior of two such transitions: the quantum anomalous Hall to normal insulator (QAH-NI), and quantum anomalous Hall to axion insulator (QAH-AXI) transitions. By introducing a new analysis protocol wherein temperature dependent variations in the magnetic coercivity are accounted for, the critical behavior of the QAH-NI and QAH-AXI transitions are evaluated over a wide range of temperature and magnetic field. Despite the uniqueness of these different transitions, quantized longitudinal resistance and Hall conductance are observed at criticality in both cases. Furthermore, critical exponents were extracted for QAH-AXI transitions occurring at magnetization reversals of two different magnetic layers. The observation of consistent critical exponents and resistances in each case, independent of the magnetic layer details, demonstrates critical behaviors in quantum anomalous Hall transitions to be of electronic rather than magnetic origin. Our finding offers a new avenue for studies of phase transition and criticality in QAH insulators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single hole spin relaxation probed by fast single-shot latched charge sensing

Hole spins have recently emerged as attractive candidates for solid-state qubits for quantum computing. Their state can be manipulated electrically by taking advantage of the strong spin-orbit interaction (SOI). Crucially, these systems promise longer spin coherence lifetimes owing to their weak interactions with nuclear spins as compared to electron spin qubits. Here we measure the spin relaxation time T 1 of a single hole in a GaAs gated lateral double quantum dot device. We propose a protocol converting the spin state into long-lived charge configurations by the SOI-assisted spin-flip tunneling between dots. By interrogating the system with a charge detector we extract the magnetic-field dependence of T 1 ∝ B -5 for fields larger than B = 0.5 T, suggesting the phonon-assisted Dresselhaus SOI as the relaxation channel. This coupling limits the measured values of T 1 from ~400 ns at B = 1.5 T up to ~60 μs at B = 0.5 T.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On the application of the MARTINI coarse-grained model to immersion of a protein in a phospholipid bilayer

An important step in the simulation of a membrane protein in a phospholipid bilayer is the correct immersion of the protein in the bilayer. Crystal structures are determined without the bilayer. Particularly for proteins with monotopic domains, it can be unclear how deeply and in which orientation the protein is being inserted in the membrane. We have previously developed a procedure combining coarse-grain (CG) with all-atom (AA) molecular dynamics (MD) simulations to insert and simulate a cytochrome P450 (CYP) possessing an N-terminal transmembrane helix connected by a flexible linker region to a globular domain that dips into the membrane. The CG simulations provide a computationally efficient means to explore different orientations and conformations of the CYP in the membrane. Converged configurations obtained in the CG simulations are then refined in AA simulations. Here, we tested different variants of the MARTINI CG model, differing in the water model, the treatment of long-range non-bonded interactions, and the implementation (GROMACS 4.5.5 vs 5.0.4), for this purpose. We examined the behavior of the models for simulating a 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine (POPC) bilayer in water and for the immersion of CYP3A4 in a POPC bilayer, and compared the CG-MD results with the previously reported experimental and simulation results. We also tested the methodology on a set of four other CYPs. Finally, we propose an optimized protocol for modeling such protein-membrane systems that provides the most plausible configurations and is computationally efficient; this incorporates the standard non-polar water model and the GROMACS 5.0.4 implementation with a reaction field treatment of long-range interactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Micrometer-resolved film dosimetry using a microscope in microbeam radiation therapy

Purpose: Microbeam radiation therapy (MRT) is a still preclinical tumor therapy approach that uses arrays of a few tens of micrometer wide parallel beams separated by a few 100 μm. The production, measurement, and planning of such radiation fields are a challenge up to now. Here, the authors investigate the feasibility of radiochromic film dosimetry in combination with a microscopic readout as a tool to validate peak and valley doses in MRT, which is an important requirement for a future clinical application of the therapy. Methods: Gafchromic{sup ®} HD-810 and HD-V2 films are exposed to MRT fields at the biomedical beamline ID17 of the European Synchrotron Radiation Facility (ESRF) and are afterward scanned with a microscope. The measured dose is compared with Monte Carlo calculations. Image analysis tools and film handling protocols are developed that allow accurate and reproducible dosimetry. The performance of HD-810 and HD-V2 films is compared and a detailed analysis of the resolution, noise, and energy dependence is carried out. Measurement uncertainties are identified and analyzed. Results: The dose was measured with a resolution of 5 × 1000 μm{sup 2} and an accuracy of 5% in the peak and between 10% and 15% in the valley region. As main causes for dosimetry uncertainties, statistical noise, film inhomogeneities, and calibration errors were identified. Calibration errors strongly increase at low doses and exceeded 3% for doses below 50 and 70 Gy for HD-V2 and HD-810 films, respectively. While the grain size of both film types is approximately 2 μm, the statistical noise in HD-V2 is much higher than in HD-810 films. However, HD-810 films show a higher energy dependence at low photon energies. Conclusions: Both film types are appropriate for dosimetry in MRT and the microscope is superior to the microdensitometer used before at the ESRF with respect to resolution and reproducibility. However, a very careful analysis of the image data is required. Dosimetry at low photon energies should be performed with great caution due to the energy sensitivity of the films. In this respect, HD-V2 films showed to have an advantage over HD-810 films. However, HD-810 films have a lower statistical noise level. When a higher resolution is required, e.g., for the dosimetry of pencil beam irradiations, noise may render HD-V2 films inapplicable.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Changuinola peat soil characteristics and gas emission raw data October 2019

This dataset comprises radiocarbon and geochemical measurements from peat and porewater samples collected across various depths at a site in Bocas del Toro, Panama. The study focuses on carbon cycling dynamics in tropical peatlands by examining carbon isotopic signatures (¹⁴C and ¹³C) and elemental compositions of bulk peat, dissolved organic carbon (DOC), carbon dioxide (CO₂), and methane (CH₄). Key parameters include radiocarbon ages and isotopic ratios (δ¹³C) of bulk peat, concentrations of carbon (%C) and nitrogen (%N), and radiocarbon content of porewater gases and dissolved organic carbon (DOC). The data provide insights into the vertical and spatial distribution of carbon sources and possible preservation and decomposition processes within tropical peat profiles, offering critical information for understanding carbon storage and greenhouse gas emissions in these ecosystems.This dataset is comprised of one main data folder containing (1) file-level metadata; (2) data dictionary; (3) field metadata; (4) carbon isotopic signatures (¹⁴C and ¹³C); (5) concentrations of carbon (%C) and nitrogen (%N); (6) radiocarbon content of porewater carbon dioxide (CO₂), and methane (CH₄) ; (7) porewater DOC; (8) bulk peat sampling protocol; (9) porewater sampling protocol; (10) porewater gas collection methods; and (11) gas extraction methods. All files are in .csv format and can be opened with any software that supports this file types.

54 ENVIRONMENTAL SCIENCES↗

Overview of NASA Glenn Aero/Mobile Communication Demonstrations

The Glenn Research Center at Lewis Field (GRC) has been involved with several other NASA field centers on various networking and RF communications demonstrations and experiments since 1998. These collaborative experiments investigated communications technologies new to aviation, such as wideband Ku satcom, L-band narrowband satcom, and IP (Internet Protocol), using commercial off-the-shelf (COTS) components These technologies can be used to distribute weather and hazard data, air traffic management and airline fleet management information, and passenger cabin Internet service.

Brooks, David↗

Overview of NASA Glenn Aero/Mobile Communications Demonstrations

The Glenn Research Center at Lewis Field (GRC) has been involved with several other NASA field centers on various networking and RF communications demonstrations and experiments since 1998. These collaborative experiments investigated communications technologies new to aviation, such as wideband Ku satcom, L-band narrowband satcom, and IP (Internet Protocol), using commercial off-the-shelf (COTS) components These technologies can be used to distribute weather and hazard data, air traffic management and airline fleet management information, and passenger cabin Internet service.

Brooks, David↗