Search NASA⌕ Search

SEARCH · Search NASA

Results for “forensics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Machine learning for fundamental spectroscopic and thermodynamic data of actinides and lanthanides

Accurately modeling optical spectra with absolute radiometric intensities is vital for nuclear forensics applications that depend on characterizing optical emissions from energetic nuclear phenomena. This requires precise knowledge of the individual atomic transition probabilities, known as Einstein A-coefficients, for each emission line. Obtaining these values theoretically or experimentally is often impractical due to the complex electronic structures and the number of transitions involved in atoms relevant to nuclear applications. In this study, we explore the use of machine learning to predict the Einstein A coefficients for atomic transitions. Seven models were evaluated that ranged from deep learning to decision tree algorithms, and found that gradient boosting performed best, specifically the Extreme Gradient Boosting (XGB) architecture, achieving a precision of 86% across transitions of 36 elements. Furthermore, the model was cross-validated using published transition probabilities reported in the literature and applied to estimate Pu plasma temperatures from a previous experiment conducted at Savannah River National Laboratory.

Atomic spectroscopy↗

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup↗

Evaluation of dried blood spot sampling for verification of exposure to chemical threat agents

Abstract Purpose Exposure to chemical threat agents (CTAs), including nerve agents, the vesicating agent sulfur mustard, and opioids, remains a significant threat to warfighter and civilian populations. Definitive analytical methods to verify exposure to CTAs require shipping refrigerated or frozen biomedical samples to reference laboratories for analysis. Logistical and financial burdens arise as the transport of biomedical samples is subject to strict restrictions and complex packaging, which, if done incorrectly, can lead to sample deterioration. The use of dried blood spot (DBS) sampling could provide operational improvements for collecting, storing, and shipping important forensic samples. Therefore, this effort focuses on developing DBS techniques with Mitra® 30-µL volumetric absorptive microsampling (VAMS®) devices for use in CTA exposure verification. Methods VAMS® devices were loaded and dried with human whole blood that was exposed to the metabolites pinacolyl methylphosphonic acid (PMPA), ethyl methylphosphonic acid (EMPA), 1,1’sulfonylbis[2-(methylsulfinyl)ethane] (SBMSE), norfentanyl, norcarfentanil, norsufentanil, and norlofentanil. Following extraction from the VAMS® devices, metabolites were detected using liquid chromatography-tandem mass spectrometry (LC–MS/MS). The methods were validated for performance by assessing sensitivity, precision, accuracy, and recovery. Results These methods were sensitive to 1 ng/mL for SBMSE, 0.5 ng/mL for PMPA, EMPA, and norfentanyl; 0.1 ng/mL for norlofentanil, and 0.05 ng/mL for norsufentanil and norcarfentanil. All methods met acceptable precision and accuracy criteria with favorable recovery. Conclusions These results demonstrated the utility of VAMS® in stabilizing human whole blood and show promise as an improved collection method for verification of exposure to various CTAs.

Toxicology↗

Static, mixed-array total evaporation for improved quantitation of plutonium minor isotopes in small samples

Actinide isotope measurements are a critical signature capability in the modern nuclear forensics “toolbox”, especially when interrogating anthropogenic constituents in real-world scenarios. Unfortunately, established methodologies, such as traditional total evaporation via thermal ionization mass spectrometry, struggle to confidently measure low abundance isotope ratios (<10 -6 ) within already limited quantities of sample. Herein, we investigate the application of static, mixed array total evaporation techniques as a straightforward means of improving plutonium minor isotope measurements, which have been resistant to enhancement in recent years because of elevated radiologic concerns. Furthermore, results are presented for small sample (~20 ng) applications involving a well-known plutonium isotope reference material, CRM-126a, and compared with traditional total evaporation methods.

07 ISOTOPE AND RADIATION SOURCES↗

Mass Spectral Library Quality Assurance by Inter-Library Comparison

A method to discover and correct errors in mass spectral libraries is described. Comparing across a set of highly curated reference libraries compounds that have the same chemical structure quickly identifies entries that are outliers. In cases where three or more entries for the same compound are compared, the outlier as determined by visual inspection was almost always found to contain the error. These errors were either in the spectrum itself or in the chemical descriptors that accompanied it. The method is demonstrated on finding errors in compounds of forensic interest in the NIST/EPA/NIH Mass Spectral Library. The target list of compounds checked was the Scientific Working Group for the Analysis of Seized Drugs (SWGDRUG) mass spectral library. Some examples of errors found are described. A checklist of errors that curators should look for when performing inter-library comparisons is provided. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial Benchmarking of the Liquid Sampling-Atmospheric Pressure Glow Discharge-Orbitrap System Against Traditional Atomic Mass Spectrometry Techniques for Nuclear Applications

The integration of the liquid sampling-atmospheric pressure glow discharge (LS-APGD) ion source with Orbitrap mass spectrometers has resulted in new opportunities in the field of isotope ratio mass spectrometry. In a field that has been dominated by thermal ionization mass spectrometry (TIMS) and inductively coupled plasma mass spectrometry (ICP-MS) on quadrupole and scanning-mode sector field analyzer platforms for highly accurate and precise measurements, the LS-APGD-Orbitrap system offers a benchtop instrument capable of meeting the rigorous International Target Values for measurement uncertainty for uranium (U). In order to benchmark the LS-APGD-Orbitrap, a series of U certified reference materials with increasing {sup 235}U isotopic composition were analyzed. By using U samples ranging in enrichment from 1 to 80%, the ability of the system to measure isotope ratios over a wide range is demonstrated. This analysis represents the first time that the LS-APGD-Orbitrap system has been used to analyze highly enriched U samples, allowing for the measurement of each of the U isotopes, including {sup 234}U and {sup 236}U-related species, which had not been achieved previously. Ultimately, the LS-APGD-Orbitrap system was able to measure CRM U-800 (assayed as {sup 235}U / {sup 238}U = 4.265622) as 4.266922, with a combined uncertainty, (u{sub c}), of 0.040%. These results are compared to those obtained using traditional elemental mass spectrometers including TIMS and ICP-MS-based instruments. The effectiveness of the LS-APGD-Orbitrap MS system for measuring U isotopes shows excellent promise in nuclear forensics, safeguards, and other nuclear weapon-based applications. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Molybdenum isotope compositions of uranium ore concentrates by double spike MC-ICP-MS

The molybdenum (Mo) isotope composition of uranium ore concentrate (UOC) has been proposed as a nuclear forensic signature due to the ubiquitous presence of Mo in the nuclear fuel cycle and to the possibility that different UOC production pathways lead to characteristic Mo isotope fractionation. Furthermore, Mo forms a volatile hexafluoride which leads to the retainment of Mo in the nuclear fuel cycle through U enrichment and reactor operation processes. As a result, it is possible that the nuclear fuel cycle generates a rich array of Mo isotope signatures. The first step in interpreting Mo isotope signatures generated during the nuclear fuel cycle is to characterize the Mo isotope composition of starting materials. In this study, a suite of UOC samples were analyzed for their Mo isotope composition in order to constrain the range of Mo isotope compositions entering the front end of the nuclear fuel cycle. Analytical protocols were developed to purify Mo from a U rich matrix prior to Mo isotope analysis by double spike MC-ICP-MS. A >3‰ variation in the 98 Mo/ 95 Mo ratio was observed in the suite of UOC samples with δ 98 Mo ranging from -1.15 to +1.96‰ relative to the NIST 3134 Mo standard reference material. The δ98Mo range observed in the UOC samples is very similar to the δ 98 Mo range observed in crustal igneous rocks and Mo-bearing minerals, suggesting that Mo isotope variability in UOC is driven by variability in the parent U ores. However, Mo isotope fractionation during UOC production is evident with one of the UOC samples being isotopically heavy relative to its parent U ore by 0.75‰, suggesting that different UOC production processes also contribute to the total Mo isotope variability observed. Overall, it is expected that the Mo isotope signatures generated during enrichment and reactor process will be clearly discernible from those generated during UOC production.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Understanding neutron capture processes in uranium deposits using combined U-Sm-Nd isotopic compositions

Valuable insights into the history and evolution of a geologic deposit can be found by investigating neutron capture reactions. Thermal neutron capture reactions occur within both the samarium (Sm) and the uranium (U) systems, where 149 Sm and 235 U can capture neutrons to become 150 Sm and 236 U, respectively. Although largely unexplored, paired measurements of 150 Sm and 236 U could be important for understanding neutron capture effects within uranium ore bodies, and such measurements are potentially useful in nuclear forensics for assessing a material's provenance or mineral exploration. In this work, we refined measurement procedures of Sm isotope compositions utilizing MC-ICPMS. While geologic reference materials were found to have indistinguishable Sm isotope compositions, we found significant isotope variations consistent with nuclear field shift among synthetic Sm standards. Here, this observation highlights that future high-precision Sm isotope investigations need to carefully evaluate synthetic standard(s) against geologic reference materials until an unfractionated and agreed-upon standard is identified. Here, we applied this method to a set of nine uranium ores from the South Australian Beverley North uranium deposits. Although 236 U excesses had been previously reported for these U ores, we found no measurable isotopic shifts in 149 Sm- 150 Sm at the current level of precision (±5 parts per million). One possible explanation for this disparity in the observed neutron capture signatures between U and Sm is that the source(s) of the U and Sm in these ores may be decoupled. This is consistent with the finding that these ores have variable 143 Nd/ 144 Nd, thus demonstrating that diverse sources were involved in the formation of the Beverley North deposits. Alternatively, this deposit may be too young (<50Ma) to have accumulated measurable neutron capture effects in Sm to be detected with the methods employed here.

Mineral exploration↗

Measuring the Noble Metal and Iodine Composition of Extracted Noble Metal Phase from Spent Nuclear Fuel Using Instrumental Neutron Activation Analysis

Mass quantities of noble metal and iodine nuclides in the metallic noble metal phase extracted from spent fuel are measured using instrumental neutron activation analysis (NAA). Nuclide presence is predicted using fission yield analysis, and mass quantification is derived from standard gamma spectroscopy and radionuclide decay analysis. The nuclide compositions of noble metal phase derived from two dissolution methods, UO2 fuel dissolved in nitric acid and UO2 fuel dissolved in ammonium-carbonate and hydrogen-peroxide solution, are compared. Lastly, the implications of the rapid analytic speed of instrumental NAA are discussed in relation to potential nuclear forensics applications.

Palomares, R. I.↗

A new thorium-229 reference material

A new reference material was characterized for 229 Th molality and thorium isotope amount ratios. This reference material is intended for use in nuclear forensic analyses as an isotope dilution mass spectrometry spike. The reference material value and expanded uncertainty (k = 2) for the 229 Th molality is (1.1498 ± 0.0016)×10 -10 mol g -1 solution. The value and expanded uncertainty (k = 2) for the n( 230 Th)/n( 229 Th) ratio is (5.18 ± 0.26)×10 -5 and the n( 232 Th)/n( 229 Th) ratio is (3.815 ± 0.092)×10 -4 .

07 ISOTOPE AND RADIATION SOURCES↗

Determination of the 161 Tb half-life

There is significant interest in the use of terbium radioisotopes for applications in cancer therapy and diagnosis. Of these, 161 Tb, a medium energy beta- and prolific auger emitter, is being investigated as a potential alternative to 177 Lu. The higher proportion of conversion electron and Auger electron emissions, and variety of low-energy gammas make 161 Tb an attractive targeted theranostic. As a product of nuclear fission, 161 Tb is also of importance to nuclear forensics. The current evaluated half-life of 6.89(2) d has a standard uncertainty that contributes significantly to the standard uncertainty of decay calculated activity determination. Furthermore, the accuracy of this evaluated half-life has been called into question by measurements reported recently at the Institute of Radiation Physics (IRP), Switzerland. In this work, the half-life of 161 Tb was measured at three independent laboratories located in the United Kingdom and United States of America for a total of five determinations using three independent measurement techniques. In conclusion, the half-life determined for 161 Tb of 6.9637(29) d confirms the observed 1 % relative increase observed by IRP, though the reported half-lives in this work and at IRP are significantly different (ζ-score = 3.1).

half-life↗

Use of Compton suppression gamma ray spectrometry to determine 239 Pu

We report 239 Pu has been characterized by gamma-ray spectroscopy for a level higher than the usual environmental ones typically needing alpha spectrometry, ICP-MS or TIMS. The higher activities typically have applications in reprocessing, safeguards verification, and nuclear forensics. For activities of hundreds of Bq/g, it is possible to use gamma ray spectrometry for 239 Pu characterization. A soil reference standard of 185 Bq/g (75 ng/g) was measured on a 79% efficient HPGe with a digital Compton suppression system. The ratios of the counting statistics for suppressed and unsuppressed uncertainties for various 239 Pu photopeaks were determined. The effects of self-attenuation on the low energy gamma rays were evaluated, and it was determined that Compton suppression was an effective characterization method of 239 Pu after accounting for self-attenuation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Editorial overview: Omics

The great complexity of biological systems and their environment poses similarly vast challenges for accurate analytical evaluations of their identity, structure and quantity. Post genomic science, has predicted much regarding the static populations of biological systems, but a further challenge for analysis is to test the accuracy of these predictions, as well as provide a better representation of the transient nature of the molecules of life. Accurate measurements of biological systems have wide applications for biological, forensic, biotechnological and healthcare fields. Therefore, the holy grail is to find a technique which can identify and quantify biological molecules with high throughput, sensitivity and robustness, as well evaluate molecular structure(s) in order to understand how the specific molecules interact and function. While wrapping all of these characteristics into one platform may sound difficult, ion mobility spectrometry (IMS) is addressing all of these challenges. Over the last decade, the number of analytical studies utilizing IMS for the evaluation of complex biological and environmental samples has greatly increased. In most cases IMS is coupled with mass spectrometry (IM-MS), but even alone IMS provides the unique capability of rapidly assessing a molecule’s structure, which can be extremely difficult with other techniques. The robustness of the IMS measurement is bourne out by its widespread use in security, environmental and military applications. The multidimensional IM-MS measurements however have been proven to be ever more powerful, as applied to complex mixtures as they enable the evaluation of both the structure and mass of every molecular component in a sample during a single measurement, without the need for continual reference calibration.

Barran, Perdita↗

A global metagenomic map of urban microbiomes and antimicrobial resistance

We present a global atlas of 4,728 metagenomic samples from mass-transit systems in 60 cities over 3 years, representing the first systematic, worldwide catalog of the urban microbial ecosystem. This atlas provides an annotated, geospatial profile of microbial strains, functional characteristics, antimicrobial resistance (AMR) markers, and genetic elements, including 10,928 viruses, 1,302 bacteria, 2 archaea, and 838,532 CRISPR arrays not found in reference databases. We identified 4,246 known species of urban microorganisms and a consistent set of 31 species found in 97% of samples that were distinct from human commensal organisms. Profiles of AMR genes varied widely in type and density across cities. Cities showed distinct microbial taxonomic signatures that were driven by climate and geographic differences. These results constitute a high-resolution global metagenomic atlas that enables discovery of organisms and genes, highlights potential public health and forensic applications, and provides a culture-independent view of AMR burden in cities.

59 BASIC BIOLOGICAL SCIENCES↗

High-dimensional isotomics, part 2: Observations of over 100 constraints on methionine's isotome

The abundances of different isotopic forms of a compound, or isotopologues, will vary based on its physical and chemical history. The number of isotopologues increases combinatorically with the size of a molecule, and even small molecules such as amino acids have thousands of potentially observable isotopic variants. However, due to the analytical challenges of separating and observing isotopologues, only a few dimensions of isotopic diversity are routinely measured. Overcoming these challenges requires both an experimental method to observe many isotopic properties and a theoretical framework for interpreting these experiments. In Part 1, we presented such a theoretical framework; here, we demonstrate an experimental method, which we apply to methionine. Our approach uses a Q Exactive HF Orbitrap to perform several “M + N experiments”, where a sample is ionized, a subset of its isotopologues with cardinal mass N daltons greater than the unsubstituted isotopologue is selected and fragmented, and the proportions of all detectable isotopic forms of those fragment ions are quantified. We perform M + 1, M + 2, M + 3, and M + 4 experiments of a methionine sample and standard where the sample has a 100 ‰ enrichment of 13C at the methyl carbon relative to the natural 13C abundance at that position in the standard, and is otherwise identical to the standard. We observe isotopic forms of 8 fragment ion species for each version of the M + N experiment. With the assistance of a forward model of expected mass spectra, we identify isotopic peaks for each fragment ion based on observed mass and abundance, screen these for data quality, and quantify abundances for 146 unique isotopic peaks at precisions of ≈ 0.3–3 ‰. We present our direct observations and use them to reconstruct the concentrations of 19 individual singly, doubly, and triply-substituted isotopologues; doing so gives fewer constraints and broader error bars than working with the direct observations, but may be more interpretable for some applications. We also examine possibilities for measuring additional peaks, which are primarily limited by the detection limit of the Orbitrap-IRMS method. We then suggest some possible uses of our direct measurements for chemical forensics and hypothesis testing. Furthermore, our results demonstrate the diversity of isotopic constraints currently observable and interpretable for organic molecules.

58 GEOSCIENCES↗

Separation of rare earth element radioisotopes by reverse-phase high-speed counter-current chromatography

Analytical scale purification of rare earth element (REE) radioisotopes is typically accomplished using cation-exchange resins (e.g. AG 50W-X8) and high-performance liquid chromatography (HPLC). Despite the variety of improvements made since the development of this separation process in the 1950s, nearest neighbor separations remain a challenge, as does the issue of irreversible sample adsorption. Herein, we report a study that evaluates the potential of high-speed counter-current chromatography (HSCCC) as an alternative method for purifying REE elements, with specific reference to separations of fission product REE of interest to nuclear forensics. Complementary HSCCC REE separation experiments, one spiked with radiotracer and REE fission product activity, allowed for in depth analysis of resulting fractions from both an elemental (inductively coupled plasma atomic emission spectroscopy, ICP-AES) and radiological (gamma-ray spectrometry, beta counting) purity perspective. The highly reproducible nature of separation profiles generated from HSCCC instruments was leveraged to simplify work-up of samples containing radioisotopes. Subsequent radioanalytical evaluation revealed minimal carryover of Eu into neighboring Sm and Tb fractions (as indicated by presence of 150Eu), and trace contamination of the Tb fraction with Y (as indicated by presence of 91Y). Subtle differences in stationary phase retention across the two columns were reflected in significant variations in decontamination factors of duplicate parallel separations. Furthermore, these differences paired with obtained distribution of radioisotopes provided valuable insights into future improvements. Collectively, this study represents a significant step forward in development of HSCCC technology for task specific REE radioisotope purification.

07 ISOTOPE AND RADIATION SOURCES↗

Extracting hidden messages in steganographic images

The eventual goal of steganalytic forensic is to extract the hidden messages embedded in steganographic images. A promising technique that addresses this problem partially is steganographic payload location, an approach to reveal the message bits, but not their logical order. It works by finding modified pixels, or residuals, as an artifact of the embedding process. This technique is successful against simple least-significant bit steganography and group-parity steganography. The actual messages, however, remain hidden as no logical order can be inferred from the located payload. This paper establishes an important result addressing this shortcoming: we show that the expected mean residuals contain enough information to logically order the located payload provided that the size of the payload in each stego image is not fixed. The located payload can be ordered as prescribed by the mean residuals to obtain the hidden messages without knowledge of the embedding key, exposing the vulnerability of these embedding algorithms. We provide experimental results to support our analysis.

97 MATHEMATICS AND COMPUTING↗

Chemical, biological, and DNA markers for tracing slaughterhouse effluent

Agricultural practices, if not managed correctly, can have a negative impact on receiving environments via waste disposal and discharge. In this study, a chicken slaughter facility on the rural outskirts of Sydney, Australia, has been identified as a possible source of persistent effluent discharge into a peri-urban catchment. Questions surrounding the facility's environmental management practices go back more than four decades. Despite there having never been a definitive determination of the facility's impact on local stream water quality, the New South Wales Environment Protection Authority (NSW EPA) has implemented numerous pollution reduction requirements to manage noise and water pollution at the slaughter facility. However, assessment of compliance remains complicated by potential additional sources of pollution in the catchment. To unravel this long-standing conundrum related to water pollution we apply a forensic, multiple lines of evidence approach to delineate the origin of the likely pollution source(s). Water samples collected between 2014 and 2016 from irrigation pipes and a watercourse exiting the slaughter facility had elevated concentrations of ammonia (max: 63,000 µg/L), nitrogen (max: 67,000 µg/L) and phosphorus (max: 39,000 µg/L), which were significantly higher than samples from adjacent streams that did not receive direct runoff from the facility. Arsenic, sometimes utilised in growth promoting compounds, was detected in water discharging from the facility up to ~4 times (max 3.84 µg/L) local background values (<0.5 µg/L), with inorganic As{sup (∑V+III)} being the dominant species. The spatial association of elevated water pollution to the facility could not unequivocally distinguish a source and consequently DNA analysis of a suspected pollution discharge event was undertaken. Analysis of catchment runoff from several local streams showed that only water sampled at the downstream boundary of the facility tested positive for chicken DNA, with traces of duck DNA being absent, which was a potential confounder given that wild ducks are present in the area. Further, PCR analysis showed that only the discharge water emanating from the slaughter facility tested positive for a generalized marker of anthropogenic pollution, the clinical class 1 integron-integrase gene. The environmental data collected over a three-year period demonstrates that the slaughter facility is indisputably the primary source of water-borne pollution in the catchment. Moreover, application of DNA and PCR for confirming pollution sources demonstrates its potential for application by regulators in fingerprinting pollution sources. - Highlights: • Multiple lines of evidence approach to delineate the origin of water pollution. • Arsenic speciation and clinical class 1 integron-integrase gene used as indicators. • Multidisciplinary approach for addressing global concerns about agricultural waste.

54 ENVIRONMENTAL SCIENCES↗