Search NASA⌕ Search

SEARCH · Search NASA

Results for “gap analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Marginal Gaps between 2 Calcium Silicate and Glass Ionomer Cements and Apical Root Dentin

Introduction: The outcome of periapical surgery has been directly improved with the introduction of novel material formulations. The aim of the study was to compare the retrograde obturation quality of the following materials: calcium silicate (Biodentine; Septodont, Saint-Maur-des-Fosses, France), mineral trioxide aggregate (MTA+; Cerkamed Company, Stalowa Wola, Poland), and glass ionomer cement (Fuji IX; GC Corporation, Tokyo, Japan). Methods: Materials' wettability was calculated concerning the contact angles of the cements measured using a glycerol drop. Cements' porosity was determined using mercury intrusion porosimetry and micro computed tomographic (mu CT) imaging. Extracted upper human incisors were retrofilled, and mu CT analysis was applied to calculate the volume of the gap between the retrograde filling material and root canal dentin. Experiments were performed before and after soaking the materials in simulated body fluid (SBF). Results: No statistically significant differences were found among the contact angles of the studied materials after being soaked in SBF. The material with the lowest nanoporosity (Fuji IX: 2.99% and 4.17% before and after SBF, respectively) showed the highest values of microporosity (4.2% and 3.1% before and after SBF, respectively). Biodentine had the lowest value of microporosity (1.2% and 0.8% before and after SBF, respectively) and the lowest value of microgap to the root canal wall ({[}10 +/- 30] x 10(-3) mm(3)). Conclusions: Biodentine and MTA possess certain advantages over Fuji IX for hermetic obturation of retrograde root canals. Biodentine shows a tendency toward the lowest marginal gap at the cement-to-dentin interface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ECAR-3386 AS-RUN THERMAL ANALYSIS OF THE AGC-3 EXPERIMENT

The third Advanced Graphite Creep (AGC-3) experiment was designed to irradiate various types of graphite specimens at a temperature of 900°C. The specimens were irradiated in an instrumented leadout capsule experiment in the east flux trap of the ATR during cycles 152B, 154B, 155A, and 155B. Temperature was monitored using twelve thermocouples located at various elevations in the reactor core, and a helium-argon gas mixture was used for gas gap temperature control of the specimens. The purpose of this analysis is to calculate specimen temperature using measured data on reactor power and helium-argon gas flows, and as-run calculations of heating rates and displacement per atom (DPA) in graphite. The accuracy of the model is assessed by comparing measured and calculated thermocouple temperatures. Uncertainty in gas gaps may preclude an accurate temperature calculation. In these cases, adjustments are made to the thermal model in order to reconcile the measured and calculated thermocouple temperature and to ensure the accuracy of the calculated specimen temperature.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

ECAR-2322 As-Run Thermal Analysis Of The AGC-2 Experiment

The second Advanced Graphite Creep (AGC-2) experiment was designed to irradiate various types of graphite specimens at a temperature of 600°C. The specimens were irradiated in an instrumented leadout capsule experiment in the south flux trap of the ATR during cycles 149A, 1498, 1508, 151A, and 1518. Temperature was monitored using twelve thermocouples located at various elevations in the reactor core, and a helium-argon gas mixture was used for gas gap temperature control of the specimens. The purpose of this analysis is to calculate specimen temperature using measured data on reactor power and helium-argon gas flows, and as-run calculations of heating rates and displacement per atom (DPA) in graphite. The accuracy of the model is assessed by comparing measured and calculated thermocouple temperatures. Uncertainty in gas gaps may preclude an accurate temperature calculation. In these cases, adjustments are made to the thermal model in order to reconcile the measured and calculated thermocouple temperature and to ensure the accuracy of the calculated specimen temperature.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental investigation and CFD analysis on cross flow in the core of PMR200

The Prismatic Modular Reactor (PMR) is one of the major Very High Temperature Reactor (VHTR) concepts, which consists of hexagonal prismatic fuel blocks and reflector blocks made of nuclear gradegraphite. However, the shape of the graphite blocks could be easily changed by neutron damage duringthe reactor operation and the shape change can create gaps between the blocks inducing the bypass flow.In the VHTR core, two types of gaps, a vertical gap and a horizontal gap which are called bypass gap and cross gap, respectively, can be formed. The cross gap complicates the flow field in the reactor core by connecting the coolant channel to the bypass gap and it could lead to a loss of effective coolant flow in the fuel blocks. Thus, a cross flow experimental facility was constructed to investigate the cross flow phenomena in the core of the VHTR and a series of experiments were carried out under varying flow rates and gap sizes. The results of the experiments were compared with CFD (Computational Fluid Dynamics) analysis results in order to verify its prediction capability for the cross flow phenomena. Fairly good agreement was seen between experimental results and CFD predictions and the local characteristics of the cross flow was discussed in detail. Based on the calculation results, pressure loss coefficient across the cross gap was evaluated, which is necessary for the thermo-fluid analysis of the VHTR core using a lumped parameter code.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Compositional dependence of optical band gap and refractive index in lead and bismuth borate glasses

Highlights: • Refractive indices increase with increasing PbO/Bi{sub 2}O{sub 3} content. • Optical band gap arises due to direct forbidden transition. • Optical band gaps decrease with increasing PbO/Bi{sub 2}O{sub 3} content. • New empirical relation between the optical band gap and the refractive index. - Abstract: We prepared a series of lead and bismuth borate glasses by varying PbO/Bi{sub 2}O{sub 3} content and studied refractive index and optical band gap as a function of glass composition. Refractive indices were measured very accurately using a Brewster’s angle set up while the optical band gaps were determined by analyzing the optical absorption edge using the Mott–Davis model. Using the Lorentz–Lorentz method and the effective medium theory, we calculated the refractive indices and then compared them with the measured values. Bismuth borate glasses show better agreement between the calculated values of the refractive index and experimental values. We used a differential method based on Mott–Davis model to obtain the type of transition and optical band gap (E{sub opt}) which in turn was compared with the value of E{sub opt} obtained using the extinction coefficient. Our analysis shows that in both lead and bismuth borate glasses, the optical band gap arises due to direct forbidden transition. With increasing PbO/Bi{sub 2}O{sub 3} content, the absorption edge shifts toward longer wavelengths and the optical band gap decreases. This behavior can be explained in terms of changes to the Pb−O/Bi−O chemical bonds with glass composition. We obtained a new empirical relation between the optical band gap and the refractive index which can be used to accurately determine the electronic oxide polarizability in lead and bismuth oxide glasses.

36 MATERIALS SCIENCE↗

Finite-key security analysis of quantum key distribution with imperfect light sources

In recent years, the gap between theory and practice in quantum key distribution (QKD) has been significantly narrowed, particularly for QKD systems with arbitrarily flawed optical receivers. The status for QKD systems with imperfect light sources is however less satisfactory, in the sense that the resulting secure key rates are often overly dependent on the quality of state preparation. This is especially the case when the channel loss is high. Very recently, to overcome this limitation, Tamaki et al proposed a QKD protocol based on the so-called 'rejected data analysis', and showed that its security in the limit of infinitely long keys is almost independent of any encoding flaw in the qubit space, being this protocol compatible with the decoy state method. Here, as a step towards practical QKD, we show that a similar conclusion is reached in the finite-key regime, even when the intensity of the light source is unstable. More concretely, we derive security bounds for a wide class of realistic light sources and show that the bounds are also efficient in the presence of high channel loss. Our results strongly suggest the feasibility of long distance provably secure communication with imperfect light sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of flow coefficients in high-multiplicity 𝑝 + Au, 𝑑 + Au, and 3 He + Au collisions at $\sqrt{s_{NN}}$ = 200 GeV

Flow coefficients (𝑣 2 and 𝑣 3 ) are measured in high-multiplicity 𝑝 + Au, 𝑑 + Au, and 3 He + Au collisions at a center-of-mass energy of $\sqrt{s_{NN}}$ = 200 GeV using the STAR detector. The measurements utilize two-particle correlations with a pseudorapidity requirement of |𝜂| < 0.9 and a pair gap of |Δ⁢𝜂| > 1.0. The primary focus is on analysis methods, particularly the subtraction of nonflow contributions. Four established nonflow subtraction methods are applied to determine 𝑣 𝑛 , validated using the HIJING event generator. 𝑣 𝑛 values are compared across the three collision systems at similar multiplicities; this comparison cancels the final-state effects and isolates the impact of initial geometry. While 𝑣 2 values show differences among these collision systems, 𝑣 3 values are largely similar, consistent with expectations of subnucleon fluctuations in the initial geometry. The ordering of 𝑣 𝑛 differs quantitatively from previous measurements using two-particle correlations with a larger rapidity gap, which, according to model calculations, can be partially attributed to the effects of longitudinal flow decorrelations. As a result, the prospects for future measurements to improve our understanding of flow decorrelation and subnucleonic fluctuations are also discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

PARTICLE IMAGE VELOCIMETRY MEASUREMENTS IN A REPRESENTATIVE GAS-COOLED PRISMATIC REACTOR CORE MODEL: FLOW IN THE COOLANT CHANNELS AND INTERSTITIAL BYPASS GAPS

Core bypass flow is one of the key issues with the prismatic Gas Turbine-Modular Helium Reactor, and it refers to the coolant that navigates through the interstitial, non-cooling passages between the graphite fuel blocks instead of traveling through the designated coolant channels. To determine the bypass flow, a double scale representative model was manufactured and installed in the Matched Index-of-Refraction flow facility; after which, stereo Particle Image Velocimetry (PIV) was employed to measure the flow field within. PIV images were analyzed to produce vector maps, and flow rates were calculated by numerically integrating over the velocity field. It was found that the bypass flow varied between 6.9-15.8% for channel Reynolds numbers of 1,746 and 4,618. The results were compared to computational fluid dynamic (CFD) pre-test simulations. When compared to these pretest calculations, the CFD analysis appeared to under predict the flow through the gap.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Prioritizing Nuclear Data Needs Using Uncertainty Analysis

Nuclear security modeling applications can often depend on very different types of lower fidelity data with significant gaps and inconsistencies. Analyzing the impact of these uncertainties on specific nuclear materials, configurations, and detection technologies provides valuable insight when determining where data improvements are needed the most. This paper describes the development and application of emerging uncertainty analysis tools that can be used to perform nuclear data uncertainty analysis and to identify and rank the impacts of individual nuclear data on national security applications. These tools constitute the framework of a comprehensive data uncertainty analysis capability that can provide improved quantitative and objective information on nuclear data needs. This information can be used to augment subject matter expert judgement. This cross-cutting research and development (R&D) capability can be applied to identify gaps and weaknesses in nuclear data to help prioritize future data investments. This in turn can help maximize benefits for specific agency missions. Lessons learned from the analysis of an illustrative example problem involving the measurement of plutonium in a neutron multiplicity counter are described herein, and areas for further methods and nuclear data uncertainty data development are provided.

Wieselquist, William↗

Strategies and Software for Machine Learning Accelerated Discovery in Transition Metal Chemistry

Machine learning the electronic structure of open shell transition metal complexes presents unique challenges, including robust and automated data set generation. In this report we introduce tools that simplify data acquisition from density functional theory (DFT) and validation of trained machine learning models using the molSimplify automatic design (mAD) workflow. We demonstrate this workflow by training and comparing the performance of LASSO, kernel ridge regression (KRR), and artificial neural network (ANN) models using heuristic, topological revised autocorrelation (RAC) descriptors we have recently introduced for machine learning inorganic chemistry. On a series of open shell transition metal complexes, we evaluate set aside test errors of these models for predicting the HOMO level and HOMO–LUMO gap. The best performing models are ANNs, which show 0.15 and 0.25 eV test set mean absolute errors on the HOMO level and HOMO–LUMO gap, respectively. Poor performing KRR models using the full 153-feature RAC set are improved to nearly the same performance as the ANNs when trained on down-selected subsets of 20–30 features. Analysis of the essential descriptors for HOMO level and HOMO–LUMO gap prediction as well as comparison to subsets previously obtained for other properties reveal the paramount importance of nonlocal, steric properties in determining frontier molecular orbital energetics. We demonstrate our model performance on diverse complexes and in the discovery of molecules with target HOMO–LUMO gaps from a large 15,000 molecule design space in minutes rather than days that full DFT evaluation would require.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spacially-Resolved Diagnostics and Modeling of Micro-Discharges (Final Report)

Optical emission spectroscopy measurements were performed with added trace probe gases in an an atmospheric pressure direct current (DC) helium microplasma. Spatially resolved measurements (resolution ≈ 6 µm) were taken across a 200 µm slot-type discharge. Stark splitting of the hydrogen Balmer-line was used to investigate the electric field distribution in the cathode sheath region. Electron densities were evaluated from the analysis of the spectral line broadenings of H-β emission. The electron density in the bulk plasma was in the range 3-8 x 10 13 cm -3 . The electric field peaked at the cathode (≈60 kV/cm) and decayed to small values over a distance of ≈ 50 µm (sheath edge) from the cathode. These experimental data were in good agreement with a self-consistent one-dimensional model of the discharge. The dependence of gas temperature on gas flow through the slot-type, atmospheric pressure microplasma in helium or argon was investigated by a combination of experiments and modeling. Spatially-resolved gas temperature profiles across the gap between the two electrodes were obtained from rotational analysis of N 2 (C 3 Π u → B 3 Π g ) emission spectra, with small amounts of N 2 added as actinometer gas. Under the same input power of 20 kW/cm 3 , the peak gas temperature in helium (≈650 K) was significantly lower than that in argon (over 1200 K). This reflects the much higher thermal conductivity of helium gas. The gas temperature decreased with increasing gas flow rate, more so in argon compared to helium. This was consistent with the fact that conductive heat losses dominate in helium microplasmas, while convective heat losses play a major role in argon microplasmas. A plasma-gas flow simulation of the microdischarge, including a chemistry set, a compressible Navier-Stokes (and mass continuity) equation, and a convective heat transport equation, was also performed. Experimental measurements were in good agreement with simulation predictions. Finally, laser scattering experiments were performed at pressures of 100s of Torr in argon or nitrogen. Laser Thomson Scattering (LTS) and Rotational Raman Scattering were employed in a novel, backscattering, confocal configuration. LTS allows direct and simultaneous measurement of both electron density (n e ) and electron temperature (T e ). For 50 mA current and over the pressure range of 300-700 Torr, LTS yielded T e = 0.9 ± 0.3 eV and n e = (6 ± 3) 10 13 cm -3 , in reasonable agreement with the predictions of a mathematical model. Rotational Raman spectroscopy (RRS) was employed for absolute calibration of the LTS signal. RRS was also applied to measure the 3D gas temperature (T g ) in nitrogen DC microdischarges. In addition, diode laser absorption spectroscopy was employed to measure the density of argon metastables (1s 5 in Paschen notations) in argon microdischarges. The gas temperature, extracted from the width of the absorption profile, was compared with T g values obtained by optical emission spectroscopy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bridging the simulator gap: Measuring motivational bias in digital nuclear power plant environments

Using digital NPP simulator facilities for research in Human Reliability Analysis (HRA) and nuclear power research is increasingly popular. For this work, we propose a method for characterizing and quantifying the gap between data collected in a simulator and data that reflect NPP operations. Using novice operators, we demonstrate how to manipulate and measure the impact of the simulator environment on operator actions. A set of biases are proposed to characterize factors introduced by the simulator environment. There are two categories of simulator bias: Environmental Biases (physical differences between the simulator and the control room), and Motivational Biases (cognitive differences between training in a simulator and operating a NPP). This study examines Motivational Bias. A preliminary causal model of Motivational Biases is introduced and tested in a demonstration experiment using 30 student operators. Data from 41 simulator sessions are analyzed. Data include crew characteristics, operator surveys, and time to recognize and diagnose the accident in the scenario. Quantitative models of the Motivational Biases using Structural Equation Modeling (SEM) are proposed. With these models, we estimate how the effects of the scenario conditions are mediated by simulator bias, and we demonstrate how to quantify the strength of these effects.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Revisiting the Valence and Conduction Band Size Dependence of PbS Quantum Dot Thin Films

We use a high signal-to-noise X-ray photoelectron spectrum of bulk PbS, GW calculations, and a model assuming parabolic bands to unravel the various X-ray and ultraviolet photoelectron spectral features of bulk PbS as well as determine how to best analyze the valence band region of PbS quantum dot (QD) films. X-ray and ultraviolet photoelectron spectroscopy (XPS and UPS) are commonly used to probe the difference between the Fermi level and valence band maximum (VBM) for crystalline and thin-film semiconductors. However, we find that when the standard XPS/UPS analysis is used for PbS, the results are often unrealistic due to the low density of states at the VBM. Instead, a parabolic band model is used to determine the VBM for the PbS QD films, which is based on the bulk PbS experimental spectrum and bulk GW calculations. Our analysis highlights the breakdown of the Brillioun zone representation of the band diagram for large band gap, highly quantum confined PbS QDs. We have also determined that in 1,2-ethanedithiol-treated PbS QD films the Fermi level position is dependent on the QD size; specifically, the smallest band gap QD films have the Fermi level near the conduction band minimum and the Fermi level moves away from the conduction band for larger band gap PbS QD films. This change in the Fermi level within the QD band gap could be due to changes in the Pb:S ratio. In addition, we use inverse photoelectron spectroscopy to measure the conduction band region, which has similar challenges in the analysis of PbS QD films due to a low density of states near the conduction band minimum.

14 SOLAR ENERGY↗

Designing clay-polymer nanocomposite sorbents for water treatment: A review and meta-analysis of the past decade

Clay-polymer nanocomposites (CPNs) have been studied for two decades as sorbents for water pollutants, but their applicability remains limited. Our aim in this review is to present the latest progress in CPN research using a meta-analysis approach and identify key steps necessary to bridge the gap between basic research and CPN application. Based on results extracted from 99 research articles on CPNs and 8 review articles on other widely studies sorbents, CPNs had higher adsorption capacities for several inorganic and organic pollutant classes (including heavy metals, oxyanions, and dyes, n = 308 observations). We applied principal component analysis, analysis of variance, and multiple linear regressions to test how CPN and pollutant properties correlated with Langmuir adsorption model coefficients. While adsorption was, surprisingly, not influenced by mineral properties, it was influenced by CPN fabrication method, polymer functional groups, and pollutant properties. For example, among the pollutant classes, heavy metals had the highest adsorption capacity but the lowest adsorption affinity. Conversely, dyes had high adsorption affinities, as reflected by the linear correlation between adsorption affinity and pollutant molecular weight. Scaling from ‘basic research’ to ‘technological application’ requires testing CPN performance in real water, application in columns, comparison to commercial sorbents, regeneration, and cost evaluation. However, our survey indicates that of the 158 observations, only 20 compared the CPN's performance to that of a commercial sorbent. We anticipate that this review will promote the design of smart and functional CPNs, which can then evolve into an effective water treatment technology.

42 ENGINEERING↗

Intrinsic axion insulating behavior in antiferromagnetic MnBi 6 Te 10

A striking feature of time-reversal symmetry (TRS) protected topological insulators (TIs) is that they are characterized by a half integer quantum Hall effect on the boundary when the surface states are gapped by time-reversal breaking perturbations. While TRS-protected TIs have become increasingly under control, magnetic analogs are still a largely unexplored territory with novel rich structures. In particular, magnetic topological insulators can also host a quantized axion term in the presence of lattice symmetries. Since these symmetries are naturally broken on the boundary, the surface states can develop a gap without external manipulation. In this work, we combine theoretical analysis, density-functional calculations and experimental evidence to reveal intrinsic axion insulating behavior in MnBi 6 Te 10 . Additionally, the quantized axion term arises from the simplest possible mechanism in the antiferromagnetic regime where it is protected by inversion symmetry and the product of a fractional translation and TRS. The anticipated gapping of the Dirac surface state at the edge is subsequently experimentally established using angle resolved photoemission spectroscopy (ARPES). As a result, this system provides the magnetic analog of the simplest TRS-protected TI with a single, gapped Dirac cone at the surface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of Mg{sub x}Cd{sub 1−x}O applying density functional theory: Stability, structural phase transition and electronic properties

Stability of B1 and B2 phases of Mg{sub x}Cd{sub 1−x}O is studied by calculating the formation energy within the framework of density functional theory applying the crystalline-orbital program package. Structural and electronic properties of the two polymorphs are reported for x=0.25, 0.50 and 0.75. The equilibrium lattice constants and bulk moduli are computed. Enthalpy calculations show pressure induced B1→B2 phase transitions at 92 GPa, 138 GPa and 212 GPa, respectively, for Mg{sub 0.25}Cd{sub 0.75}O, Mg{sub 0.50}Cd{sub 0.50}O and Mg{sub 0.75}Cd{sub 0.25}O compositions. Formation energy of ternary oxides in the B1 phase is negative with respect to mixing of B2-MgO with B1-CdO. Mixing B1-MgO with B2-CdO also leads to negative formation energy in Cd rich B1 phase ternary oxides (0≤x≤0.5). Band structure calculations predict direct band gaps in the B1 phase and indirect band gaps in the B2 phase ternary oxides. Mulliken population analysis is performed for the two polymorphs to study the charge transfer. - Graphical abstract: Diagram reveals trends in formation energy while mixing B2-MgO with B1-CdO to form B1-Mg{sub x}Cd{sub 1−x}O. Formation energies obtained from mixing isostructural and nonisostructural components are also shown. Display Omitted - Highlights: • Lattice constants and bulk moduli are computed for Mg{sub 0.25}Cd{sub 0.75}O, Mg{sub 0.50}Cd{sub 0.50}O and Mg{sub 0.75}Cd{sub 0.25}O compositions. • Enthalpy calculations signify pressure induced B1→B2 phase transitions at 92 GPa, 138 GPa and 212 GPa, respectively, in Mg{sub 0.25}Cd{sub 0.75}O, Mg{sub 0.50}Cd{sub 0.50}O and Mg{sub 0.75}Cd{sub 0.25}O. • Band structure calculations predict direct band gaps in the B1 phase ternary oxides. • In the B2 phase ternary oxides band structure calculations show valence band maximum along the Γ–X direction and the conduction band minimum at the Γ point of symmetry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Broadband single-shot electron spectrometer for GeV-class laser-plasma-based accelerators

Laser-plasma-based accelerators can provide electrons over a broad energy range and/or with large momentum spread. The electron beam energy distribution can be controlled via accurate control of laser and plasma properties, and beams with energies ranging from {approx_equal}0.5 to 1000 MeV have been observed. Measuring these energy distributions in a single shot requires the use of a diagnostic with large momentum acceptance and, ideally, sufficient resolution to accurately measure narrow energy spread beams. Such a broadband single-shot electron magnetic spectrometer for GeV-class laser-plasma-based accelerators has been developed at Lawrence Berkeley National Laboratory. Detailed descriptions of the design concept and hardware are presented, as well as a performance evaluation of the spectrometer. The spectrometer covered electron beam energies raging from 0.01 to 1.1 GeV in a single shot, and enabled the simultaneous measurement of the laser properties at the exit of the accelerator through the use of a sufficiently large pole gap. Based on measured field maps and third-order transport analysis, a few percent-level resolution and determination of the absolute energy were achieved over the entire energy range. Laser-plasma-based accelerator experiments demonstrated the capability of the spectrometer as a diagnostic and its suitability for measuring broadband electron sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗