Search NASA⌕ Search

SEARCH · Search NASA

Results for “imagers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Statistical detection of differentially abundant ions in mass spectrometry-based imaging experiments with complex designs

Mass Spectrometry Imaging (MSI) characterizes changes in chemical composition between regions of biological samples such as tissues. This translates into a statistical goal of class comparison, i.e. determining analytes that change in abundance between conditions more systematically than as expected by random variation. To reach accurate and reproducible conclusions, statistical analysis must appropriately reflect the initial research question, the design of the MSI experiment, and all the associated sources of variation. This manuscript highlights the importance of following these general statistical principles. Using the example of two case studies with complex experimental designs, and with dierent strategies of data acquisition, we demonstrate the extent to which choices made at key points of this workflow impact the results, and provide suggestions for appropriate design and analysis of MSI experiments that aim at detecting dierentially abundant analytes.

NanoDESI, mass spectrometry, MSIQuickView↗

Noninvasive Assessment of Tumor Microenvironment Using Dynamic Contrast-Enhanced Magnetic Resonance Imaging and {sup 18}F-Fluoromisonidazole Positron Emission Tomography Imaging in Neck Nodal Metastases

Purpose: To assess noninvasively the tumor microenvironment of neck nodal metastases in patients with head-and-neck cancer by investigating the relationship between tumor perfusion measured using dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and hypoxia measured by {sup 18}F-fluoromisonidazole ({sup 18}F-FMISO) positron emission tomography (PET). Methods and Materials: Thirteen newly diagnosed head-and-neck cancer patients with metastatic neck nodes underwent DCE-MRI and {sup 18}F-FMISO PET imaging before chemotherapy and radiotherapy. The matched regions of interests from both modalities were analyzed. To examine the correlations between DCE-MRI parameters and standard uptake value (SUV) measurements from {sup 18}F-FMISO PET, the nonparametric Spearman correlation coefficient was calculated. Furthermore, DCE-MRI parameters were compared between nodes with {sup 18}F-FMISO uptake and nodes with no {sup 18}F-FMISO uptake using Mann-Whitney U tests. Results: For the 13 patients, a total of 18 nodes were analyzed. The nodal size strongly correlated with the {sup 18}F-FMISO SUV ({rho} = 0.74, p < 0.001). There was a strong negative correlation between the median k{sub ep} (redistribution rate constant) value ({rho} = -0.58, p = 0.042) and the {sup 18}F-FMISO SUV. Hypoxic nodes (moderate to severe {sup 18}F-FMISO uptake) had significantly lower median K{sup trans} (volume transfer constant) (p = 0.049) and median k{sub ep} (p = 0.027) values than did nonhypoxic nodes (no {sup 18}F-FMISO uptake). Conclusion: This initial evaluation of the preliminary results support the hypothesis that in metastatic neck lymph nodes, hypoxic nodes are poorly perfused (i.e., have significantly lower K{sup trans} and k{sub ep} values) compared with nonhypoxic nodes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pathologic Validation of a Model Based on Diffusion-Weighted Imaging and Dynamic Contrast-Enhanced Magnetic Resonance Imaging for Tumor Delineation in the Prostate Peripheral Zone

Purpose: For focal boost strategies in the prostate, the robustness of magnetic resonance imaging-based tumor delineations needs to be improved. To this end we developed a statistical model that predicts tumor presence on a voxel level (2.5 Multiplication-Sign 2.5 Multiplication-Sign 2.5 mm3) inside the peripheral zone. Furthermore, we show how this model can be used to derive a valuable input for radiotherapy treatment planning. Methods and Materials: The model was created on 87 radiotherapy patients. For the validation of the voxelwise performance of the model, an independent group of 12 prostatectomy patients was used. After model validation, the model was stratified to create three different risk levels for tumor presence: gross tumor volume (GTV), high-risk clinical target volume (CTV), and low-risk CTV. Results: The model gave an area under the receiver operating characteristic curve of 0.70 for the prediction of tumor presence in the prostatectomy group. When the registration error between magnetic resonance images and pathologic delineation was taken into account, the area under the curve further improved to 0.89. We propose that model outcome values with a high positive predictive value can be used to define the GTV. Model outcome values with a high negative predictive value can be used to define low-risk CTV regions. The intermediate outcome values can be used to define a high-risk CTV. Conclusions: We developed a logistic regression with a high diagnostic performance for voxelwise prediction of tumor presence. The model output can be used to define different risk levels for tumor presence, which in turn could serve as an input for dose planning. In this way the robustness of tumor delineations for focal boost therapy can be greatly improved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Daily Orthogonal Kilovoltage Imaging Using a Gantry-Mounted On-Board Imaging System Results in a Reduction in Radiation Therapy Delivery Errors

Purpose: To determine whether the use of routine image guided radiation therapy (IGRT) using pretreatment on-board imaging (OBI) with orthogonal kilovoltage X-rays reduces treatment delivery errors. Methods and Materials: A retrospective review of documented treatment delivery errors from 2003 to 2009 was performed. Following implementation of IGRT in 2007, patients received daily OBI with orthogonal kV X-rays prior to treatment. The frequency of errors in the pre- and post-IGRT time frames was compared. Treatment errors (TEs) were classified as IGRT-preventable or non-IGRT-preventable. Results: A total of 71,260 treatment fractions were delivered to 2764 patients. A total of 135 (0.19%) TEs occurred in 39 (1.4%) patients (3.2% in 2003, 1.1% in 2004, 2.5% in 2005, 2% in 2006, 0.86% in 2007, 0.24% in 2008, and 0.22% in 2009). In 2007, the TE rate decreased by >50% and has remained low (P = .00007, compared to before 2007). Errors were classified as being potentially preventable with IGRT (e.g., incorrect site, patient, or isocenter) vs. not. No patients had any IGRT-preventable TEs from 2007 to 2009, whereas there were 9 from 2003 to 2006 (1 in 2003, 2 in 2004, 2 in 2005, and 4 in 2006; P = .0058) before the implementation of IGRT. Conclusions: IGRT implementation has a patient safety benefit with a significant reduction in treatment delivery errors. As such, we recommend the use of IGRT in routine practice to complement existing quality assurance measures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterizing the lipid and metabolite changes associated with placental function and pregnancy complications using ion mobility spectrometry-mass spectrometry and mass spectrometry imaging

Successful pregnancy is dependent upon discrete biological events, which include embryo implantation, decidualization, and placentation. Problems associated with each of these events can cause infertility or conditions such as preeclampsia. A greater understanding of the molecular changes associated with these complex processes is necessary to aid in identifying treatments for each condition. Previous nuclear magnetic resonance spectroscopy and mass spectrometry studies have been used to identify metabolites and lipids associated with pregnancy-related complications. However, due to limitations associated with conventional implementations of both techniques, novel technology developments are needed to more fully understand the initiation and development of pregnancy related problems at the molecular level. In this perspective, we describe current analytical techniques for metabolomic and lipidomic characterization of pregnancy complications and discuss the potential for new technologies such as ion mobility spectrometry-mass spectrometry and mass spectrometry imaging to contribute to a better understanding of the molecular changes that affect the placenta and pregnancy outcomes.

Environmental Molecular Sciences Laboratory↗

Chemical Imaging of Atmospheric Biomass Burning Particles from North American Wildfires

The effects of biomass burning aerosols (BBA) on radiative forcing and cloud formation depend on chemical composition and the internal structures of individual particles within smoke plumes. To improve our understanding of the chemical and physical properties of BBA emitted at different times of the day and their evolution during atmospheric aging, we conducted a study as a part of the Fire Influence on Regional to Global Environments and Air Quality field campaign. Particle samples were collected onboard a research aircraft from smoke plumes from a wildfire in eastern Oregon during late afternoon and nighttime flights on August 28, 2019. A time-resolved aerosol collector was used to collect samples on substrates for offline spectromicroscopic imaging to investigate the single-particle characteristics of BBA particles. Approximately 20,400 individual particles from 10 selected samples were analyzed using computer-controlled scanning electron microscopy coupled with energy-dispersive X-ray microanalysis, revealing their elemental composition, morphology, and viscosity. Elemental microanalysis indicated that aged potassium is likely found in the form of K 2 SO 4 , KNO 3 , and possible K-organic salts. Further chemical speciation and carbon bonding mapping within individual particles were conducted using synchrotron-based scanning transmission X-ray microscopy (STXM) coupled with near edge X-ray absorption fine structure (NEXAFS) spectroscopy. Real-time, water-soluble light absorption measurements were acquired using a particle-into-liquid sampler instrument coupled to a liquid waveguide capillary cell and total organic analyzer. In the late afternoon samples, 65% of the total particle number population consisted entirely of organic components, compared to 46% in the nighttime particles. These differences were attributed to discrepancies in composition at the time of emission and to the daytime condensation and accumulation of photochemically formed secondary organic material on existing BBA particles, a process that halts at night. Microscopy images indicated that particle viscosity was lower in the nighttime particles (<10 1 Pa·s), likely due to increased relative humidity and a higher contribution from hygroscopic inorganic components. The chemical heterogeneity of individual particles was quantified using STXM-derived mixing state parameters. The nature of carbon bonding within individual particles was inferred from the extent of carbon sp 2 hybridization derived from NEXAFS spectra. Average percentages of sp 2 hybridization range between 40% and 60%, with no noticeable differences between late afternoon and nighttime flights. These findings were compared with the online optical properties of both late afternoon and nighttime smoke plumes, providing valuable insights into the complex relationship between chemical composition and optical properties of BBA particles at different times of the day.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Unimodal Imaging of Monovalent Metal-Chelator Complexes and Lipids by MALDI Imaging Mass Spectrometry

Careful regulation of monovalent metal ions (M + ) is necessary to maintain a functional cellular system. Of these ions, appropriate sodium (Na + ) and potassium (K + ) concentrations are particularly integral for electrochemical signaling, as well as the secondary transport of nutrients and waste. Dysregulation of M + homeostasis can disrupt these mechanisms, potentially influencing the metabolism of downstream biomolecules such as lipids. Thus, the relationship between M + abundances and related biomolecular distributions must be elucidated to better understand the physiology of healthy and disordered tissues. Traditional techniques for imaging biological metal distributions include SIMS, LA-ICP-MS, and XRF; however, these capabilities are limited to elemental analysis or the analysis of molecular fragments and must be paired with other modalities to visualize distributions of more complex biomolecules within the same or similar samples. Conversely, matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI IMS) is a powerful tool often used for mapping such biomolecular distributions, but current methods are unable to detect metals within tissue. This study illustrates a novel methodology that adds metal detection to the MALDI IMS repertoire through which the simultaneous detection of M + metals and lipids is achievable. Using a robotic sprayer for homogeneous application, on-tissue deposition of the chelator deferiprone (DEF) enables subsequent detection of the ionizable metal-chelator complex by MALDI without hindering lipid detection. Our work provides proof-of-concept data for the simultaneous detection of K + , Na + , and intact lipids using MALDI IMS.

59 BASIC BIOLOGICAL SCIENCES↗

4D Proxy Imaging of Fracture Dilation and Stress Shadowing Using Electrical Resistivity Tomography During High Pressure Injections into a Dense Rock Formation

Fluid flow through fractured rock systems is governed in large part by the distribution, interconnectivity, and size of fracture apertures. In-situ stress is one of the primary factors controlling fracture aperture, and one that is altered significantly during high-pressure fluid injections or extractions. Interactions between stress, pore pressure, aperture, and fluid flow can result in complex and evolving poroelastic behavior with significant implications regarding the predictability and risk of developing and managing deep subsurface reservoirs (geothermal, fossil energy, and geologic carbon sequestration). In saturated crystalline rocks, bulk electrical conductivity is highly sensitive to porosity, and therefore to fracture aperture size and distribution. We demonstrate the use of time-lapse 3D electrical resistivity tomography for remotely monitoring stress induced changes in aperture distribution during high pressure injections into a fractured rock system at a scale of tens of meters. Results reveal a complex and continuously evolving stress field involving aperture dilations in the natural fracture system and aperture contractions in adjacent zones of shadow stress. Results provide information about the spatiotemporal changes in the system behavior and point to the potential of electrical imaging for autonomously and remotely monitoring evolving stress conditions by proxy through changes in bulk electrical conductivity.

electrical resisitivity tomography, stress, 4D Tim↗

Imaging solid–electrolyte interphase dynamics using operando reflection interference microscopy

The quality of the solid–electrolyte interphase is crucial for the performance of most battery chemistries, but its formation dynamics during operation are not well understood due to a lack of reliable operando characterization techniques. Herein, we report a dynamic, non-invasive, operando reflection interference microscope to enable the real-time imaging of the solid–electrolyte interphase during its formation and evolution processes with high sensitivity. The stratified structure of the solid–electrolyte interphase formed during four distinct steps includes the emergence of a permanent inner inorganic layer enriched in LiF, a transient assembly of an interfacial electrified double layer and a consequent emergence of a temporary outer organic-rich layer whose presence is reversible with electrochemical cycling. Reflection interference microscope imaging reveals an inverse correlation between the thicknesses of two interphasial subcomponents, implying that the permanent inorganic-rich inner layer dictates the organic-rich outer layer formation and lithium nucleation. In conclusion, the real-time visualization of solid–electrolyte interphase dynamics provides a powerful tool for the rational design of battery interphases.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Towards Resolving the Spatial Metabolome with Unambiguous Molecular Annotations in Complex Biological Systems by Coupling Mass Spectrometry Imaging with Structures for Lossless Ion Manipulations

We demonstrate the coupling of liquid extraction surface analysis (LESA) to structures for lossless ion manipulations in conjunction with serpentine ultralong path with extending routing (SLIM SUPER) ion mobility-mass spectrometry (IM-MS) for the unambiguous annotation of important isomeric glycoforms in carbon-fixing communities. A major bottleneck of current mass spectrometry imaging (MSI) methods is their inability to accurately and confidently delineate amongst isomers within a single probing area. Our methodology provides gains in both sensitivity and IM resolution, while simultaneously gaining insight on the spatial distribution of these biological isomers in a mixed organism composed of moss, cyanobacteria and fungus. We envision this methodology will be broadly applicable to other mass spectrometry imaging modalities and invaluable in multiplexed, untargeted, analyses of a single probing location.

Nagy, Gabe↗

Molded plasmonic crystals for detecting and spatially imaging surface bound species by surface-enhanced Raman scattering.

This report introduces a type of plasmonic crystal that consists of metal coated nanostructures of relief molded on a polymer film as a substrate for surface-enhanced Raman scattering (SERS). Such crystals exhibit SERS enhancement factors of {approx} 10{sup 5}, over large areas and with sufficiently high levels of uniformity for precise two-dimensional Raman mapping of surface bound monolayers. The ease of fabrication together with the high sensitivities and spatial resolution that can be achieved suggests an attractive route to SERS substrates for portable chemical warfare agent detection, environmental monitors, noninvasive imaging of biomolecules, and other applications.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Hybrid quantitative simulation on the in-line phase-contrast x-ray imaging of three dimensional samples under actual clinic imaging parameters

A hybrid model combining Monte Carlo method with diffraction theory of wave optics has been developed and applied to quantitatively simulate the in-line diffractive phase-contrast x-ray imaging of three dimensional tissue samples under actual clinic imaging parameters. The primary microcosmic interactions of medical-energy x-ray within matter including photoabsorption, Compton scattering, and coherent scattering, have been taken into account in the Monte Carlo simulation. A diffraction processing based on Fresnel diffraction theory is carried out to simulate the macroscopic diffraction effect. A comparison with experiment results has also been performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Visible imaging and spectroscopy of disruption runaway electrons in DIII-D

The first visible light images of synchrotron emission from disruption runaway electrons are presented. The forward-detected continuum radiation from runaways is identified as synchrotron emission by comparing two survey spectrometers and two visible fast cameras viewing in opposite toroidal directions. Analysis of the elongation of 2D synchrotron images of oval-shaped runaway beams indicates that the velocity pitch angle v{sub Up-Tack }/v{sub ||} ranges from 0.1 to 0.2 for the detected electrons, with energies above 25 MeV. Analysis of synchrotron intensity from a camera indicates that the tail of the runaway energy distribution reaches energies up to 60 MeV, which agrees with 0D modeling of electron acceleration in the toroidal electric field generated during the current quench. A visible spectrometer provides an independent estimate of the upper limit of runaway electron energy which is roughly consistent with energy determined from camera data. Synchrotron spectra reveal that approximately 1% of the total post-thermal quench plasma current is carried by the detected high-energy runaway population with energies in the range of 25-60 MeV; the bulk of the plasma current thus appears to be carried by relativistic electrons with energy less than 25 MeV. In addition to stable oval shapes, runaway beams with other shapes and internal structure are sometimes observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A new method for imaging nuclear threats using cosmic ray muons

Muon tomography is a technique that uses cosmic ray muons to generate three-dimensional images of volumes using information contained in the Coulomb scattering of the muons. Advantages of this technique are the ability of cosmic rays to penetrate significant overburden and the absence of any additional dose delivered to subjects under study beyond the natural cosmic ray flux. Disadvantages include the relatively long exposure times and poor position resolution and complex algorithms needed for reconstruction. Furthermore, we demonstrate a new method for obtaining improved position resolution and statistical precision for objects with spherical symmetry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-dimensional wave-number spectral analysis techniques for phase contrast imaging turbulence imaging data on large helical device

An analysis method for unfolding the spatially resolved wave-number spectrum and phase velocity from the 2D CO{sub 2} laser phase contrast imaging system on the large helical device is described. This is based on the magnetic shear technique which identifies propagation direction from 2D spatial Fourier analysis of images detected by a 6 × 8 detector array. Because the strongest modes have wave-number at the lower end of the instrumental k range, high resolution spectral techniques are necessary to clearly resolve the propagation direction and hence the spatial distribution of fluctuations along the probing laser beam. Multiple-spatial point cross-correlation averaging is applied before calculating the spatial power spectrum. Different methods are compared, and it is found that the maximum entropy method (MEM) gives best results. The possible generation of artifacts from the over-narrowing of spectra are investigated and found not to be a significant problem. The spatial resolution Δρ (normalized radius) around the peak wave-number, for conventional Fourier analysis, is ∼0.5, making physical interpretation difficult, while for MEM, Δρ ∼ 0.1.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Communication: X-ray coherent diffractive imaging by immersion in nanodroplets

Lensless x-ray microscopy requires the recovery of the phase of the radiation scattered from a specimen. Here, we demonstrate a de novo phase retrieval technique by encapsulating an object in a superfluid helium nanodroplet, which provides both a physical support and an approximate scattering phase for the iterative image reconstruction. The technique is robust, fast-converging, and yields the complex density of the immersed object. As a result, images of xenon clusters embedded in superfluid helium droplets reveal transient configurations of quantum vortices in this fragile system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗