Search NASA⌕ Search

SEARCH · Search NASA

Results for “importance sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

ISOTOPIC COMPOSITIONS OF URANIUM REFERENCE MATERIALS

Uranium isotopic compositions of a variety of U standard materials were measured at Lawrence Livermore National Laboratory and are reported here. Both thermal ionization mass spectrometry (TIMS) and multi-collector inductively couple plasma mass spectrometry (MC-ICPMS) were used to determine ratios of the naturally occurring isotopes of U. Establishing an internally coherent set of isotopic values for a range of U standards is essential for inter-laboratory comparison of small differences in {sup 238}U/{sup 235}U, as well as the minor isotopes of U. Differences of {approx} 1.3{per_thousand} are now being observed in {sup 238}U/{sup 235}U in natural samples, and may play an important role in understanding U geochemistry where tracing the origin of U is aided by U isotopic compositions. The {sup 238}U/{sup 235}U ratios were measured with a TRITON TIMS using a mixed {sup 233}U-{sup 236}U isotopic tracer to correct for instrument fractionation. this tracer was extremely pure and resulted in only very minor corrections on the measured {sup 238}U/{sup 235}U ratios of {approx} 0.03. The values obtained for {sup 238}U/{sup 235}U are: IRMM184 = 137.698 {+-} 0.020 (n = 15), SRM950a = 137.870 {+-} 0.018 (n = 8), and CRM112a = 137.866 {+-} 0.030 (n = 16). Uncertainties represent 2 s.d. of the population. The measured value for IRMM184 is in near-perfect agreement with the certified value of 137.697 {+-} 0.042. However, the U isotopic compositions of SRM950a and CRM112a are not certified. Minor isotopes of U were determined with a Nu Plasma HR MC-ICPMS and mass bias was corrected by sample/standard bracketing to IRMM184, using its certified {sup 238}U/{sup 235}U ratio. Thus, the isotopic compositions determined using both instruments are compatible. The values obtained for {sup 234}U/{sup 235}U are: SRM950a = (7.437 {+-} 0.043) x 10{sup -3} (n = 18), and CRM112a = (7.281 {+-} 0.050) x 10{sup -3} (n = 16), both of which are in good agreement with published values. The value for {sup 236}U/{sup 235}U in SRM950a was determined to be (8.48 {+-} 2.63) x 10{sup -6}, whereas {sup 236}U was not detected in CRM112a. They are currently obtaining the U isotopic composition of CRM129a. Preliminary results suggest that the {sup 238}U/{sup 235}U ratio is within error, but slightly lower than the certified value of 137.71.

58 GEOSCIENCES↗

Comparison of EXAFS Foil Spectra from Around the World

The EXAFS spectra of Cu and Pd foil from many different beamlines and synchrotrons are compared to address the dependence of the amplitude reduction factor (S{sub 0}{sup 2}) on beamline specific parameters. Even though S{sub 0}{sup 2} is the same parameter as the EXAFS coordination number, the value for S{sub 0}{sup 2} is given little attention, and is often unreported. The S{sub 0}{sup 2} often differs for the same material due to beamline and sample attributes, such that no importance is given to S{sub 0}{sup 2}-values within a general range of 0.7 to 1.1. EXAFS beamlines have evolved such that it should now be feasible to use standard S{sub 0}{sup 2} values for all EXAFS measurements of a specific elemental environment. This would allow for the determination of the imaginary energy (Ei) to account for broadening of the EXAFS signal rather than folding these errors into an effective S{sub 0}{sup 2}-value. To test this concept, we model 11 Cu-foil and 6 Pd-foil EXAFS spectra from around the world to compare the difference in S{sub 0}{sup 2}- and Ei-values.

47 OTHER INSTRUMENTATION↗

Optimization of FRAM precision for isotopic measurements on large samples of low-burnup PuO2

The gamma ray spectrum of plutonium contains measurable gamma rays ranging in energy from 60 keV to above 1 MeV. The FRAM gamma ray isotopic analysis code can analyze data from all types of HPGe detectors in this energy range typically using planar detectors in the energy range 60-210 keV or 120-451 keV and using coaxial detectors in the energy ranges 120-451 keV or 200-1001 keV. The statistical measurement precision depends upon the detector/energy range combination as well as the characteristics of the sample and any addition filters. In this paper we carry out the optimization of measurement precision for the important case of a multi-kg sample of low bumup PuO{sub 2} contained in a DOE 3013 Standard-compatible long-teml storage container.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Surfactant-assisted one-pot sample preparation for label-free single-cell proteomics

Large numbers of cells are generally required for quantitative global proteome profiling due to surface adsorption losses associated with sample processing. Such bulk measurement obscures important cell-to-cell variability (cell heterogeneity) and makes proteomic profiling impossible for rare cell populations (e.g., circulating tumor cells (CTCs)). Here we report a surfactant-assisted one-pot sample preparation coupled with mass spectrometry (MS) method termed SOP-MS for label-free global single-cell proteomics. SOP-MS capitalizes on the combination of a MS-compatible nonionic surfactant, n-Dodecyl-β-D-maltoside, and hydrophobic surface-based low-bind tubes or multi-well plates for ‘all-in-one’ one-pot sample preparation. This ‘all-in-one’ method including elimination of all sample transfer steps maximally reduces surface adsorption losses for effective processing of single cells, thus improving detection sensitivity for single-cell proteomics. This method allows convenient label-free quantification of hundreds of proteins from single human cells and ~1200 proteins from small tissue sections (close to ~20 cells). When applied to a patient CTC-derived xenograft (PCDX) model at the single-cell resolution, SOP-MS can reveal distinct protein signatures between primary tumor cells and early metastatic lung cells, which are related to the selection pressure of anti-tumor immunity during breast cancer metastasis. The approach paves the way for routine, precise, quantitative single-cell proteomics.

36 MATERIALS SCIENCE↗

XPS Analysis of Nanostructured Materials and Biological Surfaces

This paper examines the types of information that XPS can provide about a variety of nano-structured materials. Although it is sometimes not considered a “nano-scale analysis method” XPS can provide a great deal of information about elemental distributions, layer or coating structure and thicknesses, surface functionality, and even particles sizes on the 1-20 nm scale for samples types that may not be readily analyzed by other methods. This information is important for both synthetic nanostructured or nanosized materials and a variety of natural materials with nanostructure. Although the links between nanostructure materials and biological systems may not at first be obvious, many biological molecules and some organisms are the sizes of nanoparticles. The nanostructure of cells and microbes plays a significant role in how they interact with their environment. The interaction of biomolecules with nanoparticles is important for medical and toxicity studies. The interaction of biomolecules is important for sensor function and many nanomaterials are now the active elements in sensors. This paper first discusses how nanostructures influences XPS data as part of understanding how simple models of sample structure and data analysis can be used to extract information about the physical and chemical structure of the materials being analyzed. Equally important, aspects of sample and analysis limitations and challenges associated with understanding nanostructured materials are indicated. Examples of the application of XPS to nanostructured and biological systems and materials are provided.

54 ENVIRONMENTAL SCIENCES↗

Understanding the Space Weathering of Mercury Through Laboratory Experiments

Introduction: Airless surfaces across the solar system are continually modified by energetic particles from solar wind and micrometeoroid bombardment [1,2]. This process is known as space weathering, and it alters the chemical, microstructural, and optical properties of surface regoliths on airless bodies, including Mercury. On the Moon and S-type asteroids, the reflectance spectral signatures of space weathering include reddening (increasing reflectance with increasing wavelength), darkening (lowering of reflectance), and the attenuation of characteristic absorption bands [2]. Such spectral changes are driven by the production of Fe-bearing nanoparticles(npFe) through both solar wind irradiation and micrometeoroid bombardment. While our understanding of space weathering for the Moon and near-Earth S-types asteroids is advanced, insight into how these processes operate on other planetary bodies is limited. In particular, Mercury experiences a uniquely intense space weathering environment than planetary counterparts at 1 AU, including a moreintense solar wind flux and higher velocity micrometeoroid impacts [4]. Additionally, Mercury has a surface composition unique in the inner solar system, including regions of the surface with very low albedo known as the low reflectance material (LRM), which is enriched in carbon, likely graphite, up to 4wt.% [5].In addition, the concentration of Fe across Mercury’s surface islow (<2 wt.%) compared to the Moonor S-type asteroids asteroids[6]. Our understanding of the effects of space weathering on C-rich and Fe-poor phases is limited. Since Fe plays a critical role inthe development of space weathering characteristicson other airless surfaces(e.g., npFe), its limited availability may significantly affect the development of space weathering features in Mercury surface materials. We can simulate space weathering processes in the laboratory to explore their effects on the microstructural, chemical, and spectral characteristics of Mercury surface materials[7]. Here we used pulsed laser irradiation to simulate the short duration, high-temperature events associated with micrometeoroid impacts. We performed coordinated analyses including reflectance spectroscopy and electron microscopy to investigate the spectral, chemical, and microstructural changes in these mercurian analog samples. Methods: For these experiments, we usedforsteritic olivine with varying FeOcontents, a mineral phase proposed to be abundant on the surface of Mercury. We mixed each sample with graphite to simulate LRM regions of the surface. Wesynthesized the olivinesamplesat 1-bar at NASA’s Johnson Space Centerand prepared pressed powder pellets for laser irradiation [8].We prepared three samples, each with a base layer of olivineto maintain structural integrity and topped witha surface layer containing the graphite-olivine mixture: 1) Sample SC-001 San Carlos olivine(Fo90.91),2)Sample F-S-002 with0.05 wt.% FeO olivine, and 3) F-T-004 with 0.53 wt.% FeO olivine. Each sample was mixed with 5 wt.% powdered graphite and had grain sizes ranging from 45to 125μm. We irradiated each sample usinga pulsed Nd-YAG laser, (l=1064 nm, ~6 ns pulse duration, energy of 48 mJ/pulse) while undervacuumat Northern Arizona University. The laser was rastered1x and then 5x over the surfaceof each sample to simulate progressive space weathering. We collected in situreflectance spectra from the samples after each laser pulse witha Nicolet IS50 Fourier-Transform Infrared spectrometer (lfrom 0.65-2.5 μm). We used an FEI Nova NanoSEM200scanning electron microscope (SEM) and a Hitachi TM4000 Plus benchtop SEM at Purdue University to image the surface morphology and topography of the samples. We extracted thin sections for analysis in the transmission electron microscope(TEM)using the FEI Helios NanoLab 660 focused ion beam (FIB) SEM at the University of Arizona.We performed analysis of the microstructural and chemical characteristics of the samples using the 200 keV JEOL 2500 scanning TEM at Johnson Space Center. Reflectance Spectroscopy Results:Reflectance spectra for each sample are shown in Fig. 1.SC-001:The spectrum of the unirradiated sample exhibits a weak 1.0 μm absorption feature, associated with Fe2+in the olivine,and low overall reflectance (Fig. 1a). Thereflectance and the depth of the absorption band increases after 1x laser raster but are at their lowest after 5x laser rasters.F-T-004:The unirradiated sample has a blue-sloped spectrum with low reflectance without identifiable absorption features (Fig. 1b). With progressive laser irradiation, the sample reflectance increases and becomes strongly red-sloped.F-S-002:The unirradiated sample exhibits a dark, blue-slopedspectrum. The brightness of the sample increases significantly from <0.2average reflectance over >0.8 reflectance in the most irradiated sampleand thespectral slope also becomesslightly reddened (Fig. 1c). Microstructural and Chemical Analysis: Two primary alteration textures were observed in the samples exposed to simulated space weathering: 1) fluffy C-rich,and 2) vesiculated melt. The fluffy C-rich texture is composed oflow-densitydeposits distributed across the surface of the sample(Fig. 2A). Analysis of a FIB section extracted from a low-density C-rich region in sample SC-001 reveals multiple globule-type deposits, discrete from stacked graphite, likely produced via melting from the laser irradiation [9].The vesiculated melt textureis smooth and uniformly distributed across isolated regions of the sample surface. The vesicles measure up to 100s of nmin diameter. Analysis of a FIB section from this texture was extracted from sample F-T-004 reveals a layer of amorphous melt material, close to 100 nm thick and uniform across the FIB section (Fig. 2B). Isolated regions of this melt layer contain small nanoparticles, <5 nm in diameter. Chemical analysis through energy dispersive X-ray spectroscopy reveals the composition of this layer is enriched in Si and depleted in Mg and O compared to the underlying sample. Implications for Space Weathering on Mercury: Previous experiments simulating space weathering of Mercury have showndarkening and reddening of spectra[7,10].However, our use of low-Fe materials and graphite to create a sample set more analogous to the mercurian surface. Our results indicate that sample composition plays a significant and important role in the space weathering of Mercury. In particular, our spectral data demonstrates a strong correlation between spectral slope, Fe content, and simulated space weathering. While the variation in FeO content between samples F-S-002 and F-T-004 is <0.6 wt.%, the spectra deviate from flat to strongly red-sloped(F-T-004). This reddeningmay be linked to the presence of very small nanoparticles observed in the melt textures extracted from sample F-T-004. For the SC-001 sample, the fluffy C-rich textures may be developed by the amalgamation of small graphite particles into these unique morphologies. Such observations indicate that space weathering on Mercury may result in both familiar and new microstructural and chemical characteristics. References: [1]Hapke B. (2001) J. Geophys. Res.-Planet.,106,10039–10073. [2]Pieters C.M. and Noble S.K. (2016) J. Geophys. Res-Planet., 121, 1865–1884. [3] Lucey P.G., and Riner, M.A. (2011) Icarus,212, 451-462.[4]CintalaM.J.(1992)J. Geophys. Res.-Planet.,97,947–973.[5]Klima R.L.et al.(2018)Geophys.Res.Letters, 45, 2945–2953. [6]Nittler L.R., et al. (2011) Science 333, 1847-1850.[7]Sasaki S. and Kurahashi E. (2004) Space weathering on Mercury, Adv.Space Res., 33, 2152-2155.[8] Vander KaadenK.E., et al. (2018) LPSCXLIX, Abstract 1230. [9] McGlaun M.L. et al. (2019) LPSCL, Abstract 2019. [10] TrangD.et al. (2018)LPSCXLIX,Abstract2083

M S Thompson↗

Picoelectrospray Ionization Mass Spectrometry Using Narrow-bore Chemically Etched Emitters

Electrospray ionization mass spectrometry (ESI-MS) at flow rates below ~10 nL/min has been only sporadically explored due to difficulty in reproducibly fabricating emitters that can operate at lower flow rates. Here we demonstrate narrow orifice chemically etched emitters for stable electrospray at flow rates as low as 400 pL/min. Depending on the analyte concentration, we observe two types of MS signal response as a function of flow rate. At low concentrations, an optimum flow rate is observed slightly above 1 nL/min, while the signal decreases monotonically with decreasing flow rates at higher concentrations. In spite of lower MS signal, the ion utilization efficiency increases exponentially with decreasing flow rate in all cases. No unimolecular response was observed within this flow rate range during the analysis of an equimolar mixture of peptides, indicating that ionization efficiency is an analyte-dependent characteristic in given experimental conditions. While little to no gain in signal-to-noise was achieved at ultralow flow rates for concentration-limited analyses, experiments consuming the same amount of analyte suggest that mass-limited analyses will benefit strongly from the use of low flow rates and avoiding unnecessary sample dilution. By operating under optimal conditions, consumption of just 500 zmol of sample yielded signal-to-noise ratios ~10 for some peptides. These findings have important implications for the analysis of trace biological samples.

Environmental Molecular Sciences Laboratory↗

REDSHIFT EVOLUTION IN BLACK HOLE-BULGE RELATIONS: TESTING C IV-BASED BLACK HOLE MASSES

We re-examine claims for redshift evolution in black hole-bulge scaling relations based on lensed quasars. In particular, we refine the black hole (BH) mass estimates using measurements of Balmer lines from near-infrared spectroscopy obtained with Triplespec at Apache Point Observatory. In support of previous work, we find a large scatter between Balmer and UV line widths, both Mg IIlambdalambda2796, 2803 and C IVlambdalambda1548, 1550. There is tentative evidence that C III]lambda1909, despite being a blend of multiple transitions, may correlate well with Mg II, although a larger sample is needed for a real calibration. Most importantly, we find no systematic changes in the estimated BH masses for the lensed sample based on Balmer lines, providing additional support to the interpretation that black holes were overly massive compared to their host galaxies at high redshift.

79 ASTRONOMY AND ASTROPHYSICS↗

Improved Nested Sampling and Surrogate-Enabled Comparison With Other Marginal Likelihood Estimators

Estimating marginal likelihood is of central importance to Bayesian model selection and/or model averaging. The nested sampling method has been recently used together with the Metropolis-Hasting (M-H) sampling algorithm for estimating marginal likelihood. This study develops a new implementation of nested sampling by using the DiffeRential Evolution Adaptive Metropolis (DREAMzs) sampling algorithm. The two implementations of nested sampling are evaluated for four models of a synthetic groundwater flow modeling. The DREAMzs-based nested sampling outperforms the M-H-based nested sampling in terms of their accuracy, convergence, efficiency, and stability, which is attributed to the fact that DREAMzs is more robust than M-H for parameter sampling. The nested sampling method is also compared with four other methods (arithmetic mean, harmonic mean, stabilized harmonic mean, and thermodynamic integration) commonly used for estimating marginal likelihood and posterior probability of the four groundwater models. The comparative study requires hundreds of millions of model executions, which would not be possible without using surrogate models to replace the original models. Using the arithmetic mean estimator as the reference, the comparison reveals that thermodynamic integration outperforms nested sampling in terms of accuracy and stability, whereas nested sampling is more computationally efficient to reach to convergence. Here, the harmonic mean and stabilized harmonic mean methods give the worst marginal likelihood estimation. Accurate marginal likelihood estimation is important for accurate estimation of posterior model probability and better predictive performance of Bayesian model averaging.

54 ENVIRONMENTAL SCIENCES↗

A Method for Rapid and Precise Triple Oxygen Isotope Measurements via High-Temperature Conversion to CO Followed by Nickel-Catalyzed CO to CO 2 Conversion and Laser Spectroscopy

Triple oxygen isotopic compositions ( 16 O, 17 O, 18 O) have conventionally been measured via isotope ratio mass spectrometry using O 2 as an analyte. Conversion of sample oxygen to O 2 typically utilizes fluorination chemistry or catalytic equilibration between CO 2 and O 2 . Recently, laser spectroscopy has become a viable alternative for triple oxygen isotope (Δ' 17 O) measurements due to its ease and rapid throughput. Laser spectrometers are currently available for Δ' 17 O analysis of either H 2 O or CO 2 as the analyte gas. So far, these instruments have been used to measure Δ' 17 O of water, carbonate (CO 2 liberated by acid digestion), and atmospheric CO 2 samples. Here, we present a new method for high-precision Δ' 17 O analysis of CO 2 via tunable infrared laser direct absorption spectroscopy that is compatible with a wider range of geochemically important materials. This approach involves converting sample oxygen to CO 2 in two steps. First, the sample oxygen is liberated and reduced to CO by high-temperature conversion at 1450 °C in the presence of excess elemental carbon. Then, CO is catalytically converted to CO 2 over hot nickel at 350 °C. The conversion process is rapid (10 to 30 min) and quantitative. Spectroscopic Δ' 17 O analysis of the resulting CO 2 takes approximately 45 min. By measuring several oxygen isotope standards, we demonstrate that the method is precise (1σ = 12 per meg for procedural replicates) and accurate (within 11 per meg of previously reported values). The method can be applied to most pyrolytic materials where quantitative oxygen conversion is attainable, such as sulfate, phosphate, nitrate, and oxide minerals, water, and organic molecules.

Ellis, Nicholas M. [University of California, Berk↗

Artifact-Free Coring Procedures for Removing Samples from Photovoltaic Modules for Microscopic Analysis

An important step in producing more reliable and efficient photovoltaic modules is to establish a relationship between the microscopic properties of modules deployed in the field for many years and efficiency-related parameters. The first step in accomplishing this task is to be able to identify and remove small areas from these modules without causing any damage to these samples. In this work, we will describe two different procedures to core small areas of deployed and stressed solar panels produced with different materials (Si, CIGS, and CdTe), and we will prove that these processes did not damage the cored material. We will also show that the coring procedure changes for different types of photovoltaic modules.

14 SOLAR ENERGY↗

Formation of Kinetically Trapped Nanoscopic Unilamellar Vesicles from Metastable Nanodiscs

Zwitterionic long-chain lipids (e.g., dimyristoyl phosphatidylcholine, DMPC) spontaneously form onion-like, thermodynamically stable structures in aqueous solutions (commonly known as multilamellar vesicles, or MLVs). It has also been reported that the addition of zwitterionic short-chain (i.e., dihexanoyl phosphatidylcholine, DHPC) and charged long-chain (i.e., dimyristoyl phosphatidylglycerol, DMPG) lipids to zwitterionic long-chain lipid solutions results in the formation of unilamellar vesicles (ULVs). Here, we report a kinetic study on lipid mixtures composed of DMPC, DHPC, and DMPG. Two membrane charge densities (i.e., [DMPG]/[DMPC] = 0.01 and 0.001) and two solution salinities (i.e., [NaCl] = 0 and 0.2 M) are investigated. Upon dilution of the high-concentration samples at 50 °C, thermodynamically stable MLVs are formed, in the case of both weakly charged and high salinity solution mixtures, implying that the electrostatic interactions between bilayers are insufficient to cause MLVs to unbind. Importantly, in the case of these samples small angle neutron scattering (SANS) data show that, initially, nanodiscs (also known as bicelles) or bilayered ribbons form at low temperatures (i.e., 10 °C), but transform into uniform size, nanoscopic ULVs after incubation at 10 °C for 20 h, indicating that the nanodisc is a metastable structure. The instability of nanodiscs may be attributed to low membrane rigidity due to a reduced charge density and high salinity. Moreover, the uniform-sized ULVs persist even after being heated to 50 °C, where thermodynamically stable MLVs are observed. This result clearly demonstrates that these ULVs are kinetically trapped, and that the mechanical properties (e.g., bending rigidity) of 10 C nanodiscs favor the formation of nanoscopic ULVs over that of MLVs. From a practical point of view, this method of forming uniform-sized ULVs may lend itself to their mass production, thus making them economically feasible for medical applications that depend on monodisperse lipid-based systems for therapeutic and diagnostic purposes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Application of visual psychophysics to the design of video systems for use in space

A series of two-alternative forced choice experiments was conducted to compare the sharpness of televised moving images sampled using cardinal or diagonal patterns with reference images of varying resolution. The results indicate that both image sampling and resolution orientation play an important role in determining apparent sharpness of the images. If an image has better cardinal than diagonal resolution, the apparent sharpness is significantly greater. Thus, if the polar distribution of resolution is limited by the sampling process, diagonal sampling can be expected to yield a sharper image than cardinal sampling with the same number of pixels.

Glenn, William E.↗

Abundant ammonia and nitrogen-rich soluble organic matter in samples from asteroid (101955) Bennu

Organic matter in meteorites reveals clues about early Solar System chemistry and the origin of molecules important to life, but terrestrial exposure complicates interpretation. Samples returned from the B-type asteroid Bennu by the Origins, Spectral Interpretation, Resource Identification, and Security–Regolith Explorer mission enabled us to study pristine carbonaceous astromaterial without uncontrolled exposure to Earth’s biosphere. Here we show that Bennu samples are volatile rich, with more carbon, nitrogen and ammonia than samples from asteroid Ryugu and most meteorites. Nitrogen-15 isotopic enrichments indicate that ammonia and other N-containing soluble molecules formed in a cold molecular cloud or the outer protoplanetary disk. We detected amino acids (including 14 of the 20 used in terrestrial biology), amines, formaldehyde, carboxylic acids, polycyclic aromatic hydrocarbons and N-heterocycles (including all five nucleobases found in DNA and RNA), along with ~10,000 N-bearing chemical species. All chiral non-protein amino acids were racemic or nearly so, implying that terrestrial life’s left-handed chirality may not be due to bias in prebiotic molecules delivered by impacts. The relative abundances of amino acids and other soluble organics suggest formation and alteration by low-temperature reactions, possibly in NH 3 -rich fluids. Bennu’s parent asteroid developed in or accreted ices from a reservoir in the outer Solar System where ammonia ice was stable.

79 ASTRONOMY AND ASTROPHYSICS↗

Abundant Ammonia and Nitrogen-Rich Soluble Organic Matter in Samples From Asteroid (101955) Bennu

Organic matter in meteorites reveals clues about early Solar System chemistry and the origin of molecules important to life, but terrestrial exposure complicates interpretation. Samples returned from the B-type asteroid Bennu by the Origins, Spectral Interpretation, Resource Identifcation, and Security–Regolith Explorer mission enabled us to study pristine carbonaceous astromaterial without uncontrolled exposure to Earth’s biosphere. Here we show that Bennu samples are volatile rich, with more carbon, nitrogen and ammonia than samples from asteroid Ryugu and most meteorites. Nitrogen-15 isotopic enrichments indicate that ammonia and other N-containing soluble molecules formed in a cold molecular cloud or the outer protoplanetary disk. We detected amino acids (including 14 of the 20 used in terrestrial biology), amines, formaldehyde, carboxylic acids, polycyclic aromatic hydrocarbons and N-heterocycles (including all fve nucleobases found in DNA and RNA), along with ~10,000 N-bearing chemical species. All chiral non-protein amino acids were racemic or nearly so, implying that terrestrial life’s left-handed chirality may not be due to bias in prebiotic molecules delivered by impacts. The relative abundances of amino acids and other soluble organics suggest formation and alteration by low-temperature reactions, possibly in NH3-rich fuids. Bennu’s parent asteroid developed in or accreted ices from a reservoir in the outer Solar System where ammonia ice was stable.

Daniel P Glavin↗

Environment Partitioning and Reactivity of Polybrominated Diphenylethers

Polybrominated diphenyl ethers (PBDEs) are an important class of flame retardants. Annual global demand for these compounds was over 67,000 metric tons in 2001. PBDEs have recently been extensively investigated as environmental contaminants because they have been detected in air, sediment, and tissue samples from urban and remote areas. Important issues include quantifying PBDE partitioning in various environmental compartments, and elucidating transformation pathways. The partitioning of PBDE congeners to aerosols was estimated for 16 sites in the United States, Canada, and Mexico. The aerosol particles were PM2.5, the total suspended particle (TSP) concentration varied between 3.0 - 55.4 micro g/cubic meter, and the organic fraction ranged from 11 - 41%; these data are published values for each site. It is estimated that the largest fraction of each PBDE associated with the aerosol particles occurs in Mexico City, and the smallest fraction in Colorado Plateau. Although the organic fraction in Mexico City is about 60% of that observed in the Colorado Plateau, the TSP is larger by a factor of about 18.5, and it is the difference in TSP that strongly influences the fraction of particle-bound PBDE in this case. PBDE partitioning to PM2.5 particles also varies seasonally because of temperature variations. For the less brominated congeners the percentage that is particle-bound is relatively low, regardless of air temperature. In contrast, the heavier congeners exhibit a significant temperature dependence: as the temperature decreases (fall, winter) the percentage of PBDE that is particle-bound increases. The partitioning calculations complement experimental data indicating that decabromodiphenyl ether (DBDE) dissolved in hexane transforms very rapidly when irradiated with solar light. DBDE is the most highly brominated PBDE congener (10 bromine atoms) and occurs in the commercial formulation which is subject to the largest global demand.

Hua, Inez↗

Broadband, 920-nm mirror thin film damage competition

This year’s competition proposed to survey the state-of-the-art broadband, near-IR multilayer dielectric (MLD) mirrors designed for ultra-short, pulsed laser applications. The requirements for the coatings were a minimum reflection of 99.5% at 45-degree incidence angle for S-polarization from 830 nm to 1010 nm and group delay dispersion (GDD) < ± 50 fs 2 . The participants in this effort selected the coating materials, coating design, and deposition method. Samples were damage tested at a single testing facility to enable direct comparison among the participants using a 25 ± 5 fs OPCPA laser system operating at 5 Hz. A double blind test assured sample and submitter anonymity. The damage performance results, sample rankings, details of the deposition processes, coating materials and substrate cleaning methods are shared here. We found that multilayer coatings using tantala and/or hafnia as high index materials were top performers within several coating deposition groups. Specifically, dense coatings by ion-beam sputtering (IBS), magnetron sputtering (MS), and electron-beam ion assisted deposition (e-beam IAD) exhibited highest damage initiation onset (LIDT) while e-beam coatings were low performers. In addition, damage growth onset (LDGT) was also examined and the results are reported here for all samples as this performance metric plays an important role in establishing the safe operational conditions for larger aperture, ultrashort pulsed lasers. As a result, not all coating samples in the survey met the GDD requirements stated above and associated measurements are discussed in the context of the present and past competitions focused on similar broadband, near-IR MLD coatings.

42 ENGINEERING↗

Creation and characterization of warm dense matter isochorically heated by an intense laser-driven proton beam to temperatures exceeding 100 eV

The warm dense matter (WDM) is an exotic state of matter encountered in inertial confinement implosions for fusion energy, as well as the interiors of giant planets like Jupiter, brown dwarfs, the atmospheres of white dwarfs, neutron star crusts, and newly discovered exo-planets. One efficient way to create WDM is to use protons accelerated by a high-intensity short-pulse laser to isochorically heat dense samples to WDM states. Despite its importance, direct temperature measurements within WDM targets are scarce. This study utilizes an intense proton beam generated by the kilojoule EP laser further focused and guided by a curved foil and cone structure to efficiently heat a thin copper sample. A high-resolution streaked spectrometer tuned to copper K α fluorescence lines provided bulk temperature measurements every ~2 ps, revealing temperatures exceeding 100 eV in under 50 ps. Particle-in-cell simulations of proton transport and energy deposition closely matched the observed heating dynamics, including transverse temperature gradients revealed by the broadening of K α lines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗