Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear accelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

ILC cryogenic systems reference design

A Global Design Effort (GDE) began in 2005 to study a TeV scale electron-positron linear accelerator based on superconducting radio-frequency (RF) technology, called the International Linear Collider (ILC). In early 2007, the design effort culminated in a reference design for the ILC, closely based on the earlier TESLA design. The ILC will consist of two 250 GeV linacs, which provide positron-electron collisions for high energy physics research. The particle beams will be accelerated to their final energy in superconducting niobium RF cavities operating at 2 kelvin. At a length of about 12 km each, the main linacs will be the largest cryogenic systems in the ILC. Positron and electron sources, damping rings, and beam delivery systems will also have a large number and variety of other superconducting RF cavities and magnets, which require cooling at liquid helium temperatures. Ten large cryogenic plants with 2 kelvin refrigeration are envisioned to cool the main linacs and the electron and positron sources. Three smaller cryogenic plants will cool the damping rings and beam delivery system components predominately at 4.5 K. This paper describes the cryogenic systems concepts for the ILC.

43 PARTICLE ACCELERATORS↗

Real-Time Target Position Estimation Using Stereoscopic Kilovoltage/Megavoltage Imaging and External Respiratory Monitoring for Dynamic Multileaf Collimator Tracking

Purpose: To develop a real-time target position estimation method using stereoscopic kilovoltage (kV)/megavoltage (MV) imaging and external respiratory monitoring, and to investigate the performance of a dynamic multileaf collimator tracking system using this method. Methods and Materials: The real-time three-dimensional internal target position estimation was established by creating a time-varying correlation model that connected the external respiratory signals with the internal target motion measured intermittently using kV/MV imaging. The method was integrated into a dynamic multileaf collimator tracking system. Tracking experiments were performed for 10 thoracic/abdominal traces. A three-dimensional motion platform carrying a gold marker and a separate one-dimensional motion platform were used to reproduce the target and external respiratory motion, respectively. The target positions were detected by kV (1 Hz) and MV (5.2 Hz) imaging, and external respiratory motion was captured by an optical system (30 Hz). The beam-target alignment error was quantified as the positional difference between the target and circular beam center on the MV images acquired during tracking. The correlation model error was quantified by comparing a model estimate and measured target positions. Results: The root-mean-square errors in the beam-target alignment that had ranged from 3.1 to 7.6 mm without tracking were reduced to <1.5 mm with tracking, except during the model building period (6 s). The root-mean-square error in the correlation model was submillimeters in all directions. Conclusion: A novel real-time target position estimation method was developed and integrated into a dynamic multileaf collimator tracking system and demonstrated an average submillimeter geometric accuracy after initializing the internal/external correlation model. The method used hardware tools available on linear accelerators and therefore shows promise for clinical implementation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Practical transverse matching of a high intensity SNS linac

It is important to accomplish adequate matching for a high intensity linear accelerator such as the SNS linac to minimize the mismatch and potential beam loss. In the early stage of the SNS linac design, there was a discussion over whether to match the core or to match the tail. A study shows that the matching by minimizing rms emittances reduces both the core emittance and the beam tail, providing a robust matching for the SNS Drift Tube Linac, when an emittance scanner is available. For the transverse matching of other sections of the SNS linac where only wire-scanners are available, we use beam size data obtained from multiple wire-scanners installed in series to do the matching with the help of an envelope code such as Trace3D. It is verified that matching is improved through the matching technique based on the beam profile measurements from wire-scanners in series.

43 PARTICLE ACCELERATORS↗

The super separator spectrometer (S{sup 3}) for SPIRAL2 stable beams.

S{sup 3} (Super Separator Spectrometer) is a device designed for experiments with the very high intensity stable beams of LINAG, the superconducting linear accelerator of GANIL, which will be built in the framework of SPIRAL2. These beams can reach intensities exceeding 100p{mu}A for lighter ions. These unprecedented intensities open new opportunities in several physics domains, e.g. super-heavy and very-heavy element properties, spectroscopy at and beyond the dripline, isomer and ground state properties, and the products of multi-nucleon transfer and deep-inelastic reactions. An international collaboration has been formed for proposing physics experiments and developing technical solutions for this new instrument. We present here the optical layout of the spectrometer and the studies of its multipole magnets.

43 PARTICLE ACCELERATORS↗

Theory of photoemission from cathodes with disordered surfaces

Linear-accelerator-based applications like x-ray free electron lasers, ultrafast electron diffraction, electron beam cooling, and energy recovery linacs use photoemission-based cathodes in photoinjectors for electron sources. Most of these photocathodes are typically grown as polycrystalline materials with disordered surfaces. In order to understand the mechanism of photoemission from such cathodes and completely exploit their photoemissive properties, it is important to develop a photoemission formalism that properly describes the subtleties of these cathodes. Here, the Dowell–Schmerge (D–S) model often used to describe the properties of such cathodes gives the correct trends for photoemission properties like the quantum efficiency (QE) and the mean transverse energy (MTE) for metals; however, it is based on several unphysical assumptions. In the present work, we use Spicer’s three-step photoemission formalism to develop a photoemission model that results in the same trends for QE and MTE as the D–S model without the need for any unphysical assumptions and is applicable to defective thin-film semiconductor cathodes along with metal cathodes. As an example, we apply our model to Cs 3 Sb thin films and show that their near-threshold QE and MTE performance is largely explained by the exponentially decaying defect density of states near the valence band maximum.

43 PARTICLE ACCELERATORS↗

Beam test of a grid-less multi-harmonic buncher.

The Argonne Tandem Linear Accelerator System (ATLAS) is the first superconducting heavy-ion linac in the world. Currently ATLAS is being upgraded with the Californium Rare Ion Breeder Upgrade (CARIBU). The latter is a funded project to expand the range of shortlived, neutron-rich rare isotope beams available for nuclear physics research at ATLAS. To avoid beam losses associated with the existing gridded multi-harmonic buncher (MHB), we have developed and built a grid-less four-harmonic buncher with fundamental frequency of 12.125 MHz. In this paper, we report the results of the MHB commissioning and ATLAS beam performance with the new buncher.

43 PARTICLE ACCELERATORS↗

Residual Resistance Data from Cavity Production Projects at Jefferson Lab

A fundamental limitation towards achieving high quality factors in superconducting radio-frequency cavities is the so-called residual resistance. Understanding and controlling the residual resistance has important implications towards improving the efficiency and reduce the operating cost of continuous wave superconducting linear accelerators. In this contribution we will report on the residual resistance values obtained from measurements of the quality factor of a large set of cavities, with resonant frequency between 805 MHz and 1.5 GHz, all of them processed and tested at Jefferson Lab. Surface treatments included both buffered chemical polishing and electropolishing. The results indicate an approximate value of the residual resistance of about 7-10 n Omega.

43 PARTICLE ACCELERATORS↗

Electron beam quality control using an amorphous silicon EPID

An amorphous silicon EPID has been investigated to determine whether it is capable of quality control constancy measurements for linear accelerator electron beams. The EPID grayscale response was found to be extremely linear with dose over a wide dose range and, more specifically, for exposures of 95-100 MU. Small discrepancies of up to 0.8% in linearity were found at 6 MeV (8-15 MeV showed better agreement). The shape of the beam profile was found to be significantly altered by scatter in air over the approximately 60 cm gap between the end of the applicator and the EPID. Nevertheless, relative changes in EPID-measured profile flatness and symmetry were linearly related to changes in these parameters at 95 cm focus to surface distance (FSD) measured using a 2D diode array. Similar results were obtained at 90 deg. and 270 deg. gantry angles. Six months of daily images were acquired and analyzed to determine whether the device is suitable as a constancy checker. EPID output measurements agreed well with daily ion chamber measurements, with a 0.8% standard deviation in the difference between the two measurement sets. When compared to weekly parallel plate chamber measurements, this figure dropped to 0.5%. A Monte Carlo (MC) model of the EPID was created and demonstrated excellent agreement between MC-calculated profiles in water and the EPID at 95 and 157 cm FSD. Good agreement was also found with measured EPID profiles, demonstrating that the EPID provides an accurate measurement of electron profiles. The EPID was thus shown to be an effective method for performing electron beam daily constancy checks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dosimetry experiments at the MEDUSA Facility (Little Mountain).

A series of experiments on the MEDUSA linear accelerator radiation test facility were performed to evaluate the difference in dose measured using different methods. Significant differences in dosimeter-measured radiation dose were observed for the different dosimeter types for the same radiation environments, and the results are compared and discussed in this report.

43 PARTICLE ACCELERATORS↗

Designs for a Linac-Ring LHeC

We consider three scenarios for the recirculating electron linear accelerator (RLA) of a linac-ring type electron-proton collider based on the LHC (LHeC): (i) a pulsed linac with a final beam energy of 60 GeV ['p-60'], (ii) a higher luminosity configuration with two cw linacs and energy-recovery (ERL) also at 60 GeV ['erl'], and (iii) a high energy option using a pulsed linac with 140-GeV final energy ['p-140']. We discuss parameters, synchrotron radiation, footprints, and performance for the three scenarios.

43 PARTICLE ACCELERATORS↗

Los Alamos neutron science center nuclear weapons stewardship and unique national scientific capabilities

This presentation gives an overview of the Los Alamos Neutron Science Center (LANSCE) and its contributions to science and the nuclear weapons program. LANSCE is made of multiple experimental facilities (the Lujan Center, the Weapons Neutron Research facility (WNR), the Ultra-Cold Neutron facility (UCN), the proton Radiography facility (pRad) and the Isotope Production Facility (IPF)) served by the its kilometer long linear accelerator. Several research areas are supported, including materials and bioscience, nuclear science, materials dynamics, irradiation response and medical isotope production. LANSCE is a national user facility that supports researchers worldwide. The LANSCE Risk Mitigation program is currently in progress to update critical accelerator equipment to help extend the lifetime of LANSCE as a key user facility. The Associate Directorate of Business Sciences (ADBS) plays an important role in the continued success of LANSCE. This includes key procurement support, human resource support, technical writing support, and training support. LANSCE is also the foundation of the future signature facility MARIE (Matter-Radiation Interactions in Extremes).

43 PARTICLE ACCELERATORS↗

Variable Energy 2-MeV S-Band Linac for X-ray and Other Applications

This paper describes the design and operation of a compact, 2-MeV, S-band linear accelerator (linac) with variable energy tuning and short-pulse operation down to 15 ps with 100-A peak current. The design consists of a buncher cavity for short-pulse operation and two coupled resonator sections for acceleration. Single-pulse operation is accomplished through a fast injector system with a 219-MHz subharmonic buncher. The machine is intended to support a variety of applications, such as x-ray and electron beam diagnostic development, and recently, electron diffraction studies of phase transitions in shocked materials.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status of the NSLS-II Injection System Design

The NSLS-II is a new ultra-bright 3rd generation 3 GeV light source that will be built at Brookhaven National Laboratory. Its design is well under way. The requirements for the compact injector complex, which will continuously provide 3 GeV electrons for top-off injection into the storage ring, are demanding: high reliability, relatively high charge and low losses. The injector consists of a linear accelerator, a full-energy booster, as well as transport lines, and an injection straight section. In this paper we give an overview of the NSLS-II injector, discuss its status, specifications, and the design challenges.

43 PARTICLE ACCELERATORS↗

Beam dynamics simulations of the NML photoinjector at Fermilab

Fermilab is currently constructing a superconducting RF (SRF) test linear accelerator at the New Muon Lab (NML). Besides testing SRF accelerating modules for ILC and Project-X, NML will also eventually support a variety of advanced accelerator R&D experiments. The NML incorporates a 40 MeV photoinjector capable of providing electron bunches with variable parameters. The photoinjector is based on the 1+1/2 cell DESY-type gun followed by two superconducting cavities. It also includes a magnetic bunch compressor, a round-to-flat beam transformer and a low-energy experimental area for beam physics experiments and beam diagnostics R&D. In this paper, we explore, via beam dynamics simulations, the performance of the photoinjector for different operating scenarios.

43 PARTICLE ACCELERATORS↗

Neutron Cross Section Measurements at ORELA for Improved Nuclear Data and Their Application

Many older neutron cross-section evaluations from libraries such as ENDF/B-VI or JENDL-3.2 exhibit deficiencies or do not cover energy ranges that are important for criticality safety applications. These deficiencies may occur in the resolved and unresolved-resonance regions. Consequently, these evaluated data may not be adequate for nuclear criticality calculations where effects such as self-shielding, multiple scattering, or Doppler broadening are important. To support the Nuclear Criticality Predictability Program, neutron cross-section measurements have been initiated at the Oak Ridge Electron Linear Accelerator (ORELA). ORELA is the only high-power white neutron source with excellent time resolution still operating in the United States. It is ideally suited to measure fission, neutron total, and capture cross sections in the energy range from 1 eV to {approx}600 keV, which is important for many nuclear criticality safety applications.

43 PARTICLE ACCELERATORS↗

Experiment to Detect Accelerating Modes in a Photonic Bandgap Fiber

An experimental effort is currently underway at the E-163 test beamline at Stanford Linear Accelerator Center to use a hollow-core photonic bandgap (PBG) fiber as a high-gradient laser-based accelerating structure for electron bunches. For the initial stage of this experiment, a 50pC, 60 MeV electron beam will be coupled into the fiber core and the excited modes will be detected using a spectrograph to resolve their frequency signatures in the wakefield radiation generated by the beam. They will describe the experimental plan and recent simulation studies of candidate fibers.

43 PARTICLE ACCELERATORS↗

E166: Polarized Positrons and Polarimetry

A proof-of-principle experiment has been carried out in the Final Focus Test Beam (FFTB) at Stanford Linear Accelerator Center (SLAC) to demonstrate production of polarized positrons in a manner suitable for implementation at the International Linear Collider (ILC). A helical undulator of 2.54 mm period and 1 -m length produced circularly polarized photons with a first harmonic endpoint energy of 8 MeV when traversed by a 46.6 GeV electron beam. The polarized photons were converted to polarized positrons in a 0.2-radiation-length tungsten target. The polarization of these positrons was measured using a Compton transmission polarimeter to have peak value in excess of 80%.

43 PARTICLE ACCELERATORS↗

Fabrication of Cryogenic Manganite Bolometers to Measure the Total Energy at the LCLS Free Electron X-ray Laser

We are developing cryogenic bolometers to measure the total energy of the Linac Coherent Light Source (LCLS) free electron X-ray laser that is currently being built at the Stanford Linear Accelerator Center. LCLS will produce ultrashort {approx}200 fs X-ray laser pulses with {approx}10{sup 13} photons at 0.8 keV up to {approx}10{sup 12} photons at 8 keV per pulse at a repeat interval as short as 8 ms, and will be accompanied by a halo of spontaneous undulator radiation. Our bolometer consists of a 375 {micro}m thick Si absorber and a Nd{sub 0.67}Sr{sub 0.33}MnO{sub 3} sensor operated at its metal-insulator transition. It will measure the total energy of each pulse with a precision of <1%, and is designed to meet the conflicting requirements of radiation hardness, sensitivity, linearity over a dynamic range of three orders of magnitude, and readout speed compatible with the LCLS pulse rate. Here we discuss bolometer design and fabrication, and the photoresponse of prototype devices to pulsed optical lasers.

42 ENGINEERING↗