Search NASA⌕ Search

SEARCH · Search NASA

Results for “load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Impacts of cellulase deactivation at the moving air–liquid interface on cellulose conversions at low enzyme loadings

Background: We recently confirmed that the deactivation of T. reesei cellulases at the air–liquid interface reduces microcrystalline cellulose conversion at low enzyme loadings in shaken flasks. It is one of the main causes for lowering of cellulose conversions at low enzyme loadings. However, supplementing cellulases with small quantities of surface-active additives in shaken flasks can increase cellulose conversions at low enzyme loadings. It was also shown that cellulose conversions at low enzyme loadings can be increased in unshaken flasks if the reactions are carried for a longer time. This study further explores these recent findings to better understand the impact of air–liquid interfacial phenomena on enzymatic hydrolysis of cellulose contained in Avicel, Sigmacell, α-cellulose, cotton linters, and filter paper. The impacts of solids and enzyme loadings, supplementation with nonionic surfactant Tween 20 and xylanases, and application of different types of mixing and reactor designs on cellulose hydrolysis were also evaluated.Results: Avicel cellulose conversions at high solid loading were more than doubled by minimizing loss of cellulases to the air–liquid interface. Maximum cellulose conversions were high for surface-active supplemented shaken flasks or unshaken flasks because of low cellulase deactivation at the air–liquid interface. The nonionic surfactant Tween 20 was unable to completely prevent cellulase deactivation in shaken flasks and only reduced cellulose conversions at unreasonably high concentrations.Conclusions: High dynamic interfacial areas created through baffles in reactor vessels, low volumes in high-capacity vessels, or high shaking speeds severely limited cellulose conversions at low enzyme loadings. Precipitation of cellulases due to aggregation at the air–liquid interface caused their continuous deactivation in shaken flasks and severely limited solubilization of cellulose.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of watershed-derived mass loads to prioritize TMDL decision-making

A total maximum daily load (TMDL) for oxygen demanding substances is being implemented in the San Joaquin River (SJR) in California (USA) due to frequently occurring low dissolved oxygen conditions. The SJR is a eutrophic river, heavily impacted by agriculture. A mass balance was developed to identify the sources of oxygen-demanding substances and nutrients to the river with the objective of providing a scientific basis for management actions needed to meet TMDL requirements. Data were collected for flow and water quality and mass loads calculated for sites within the main stem of the SJR, river inputs (tributaries), and diversions in the study area. Using a quadrant analysis, tributary flows and loads are ranked to identify targets for water quality improvement efforts. Additionally, all mass loads were summed (inputs minus diversions) and compared with observed loads at the downstream limit of the study area. The mass balance analysis identifies major contributors of mass loads and mass balance closure is assessed for each constituent. These analysis methods inform the TMDL process which includes a load allocation, and is useful for determining locations for implementation of improvement projects needed to improve the health of the river.

54 ENVIRONMENTAL SCIENCES↗

Plutonium loading capacity of reillex™ hpq anion exchange column - AFS-2 plutonium flowsheet for mox

Radioactive plutonium (Pu) anion exchange column experiments using scaled HB-Line designs were performed to investigate the dependence of column loading performance on the feed composition in the H-Canyon dissolution process for plutonium oxide (PuO 2 ) product shipped to the Mixed Oxide (MOX) Fuel Fabrication Facility (MFFF). These loading experiments show that a representative feed solution containing ~5 g Pu/L can be loaded onto Reillex™ HPQ resin from solutions containing 8 M total nitrate and 0.1 M KF provided that the F is complexed with Al to an [Al]/[F] molar ratio range of 1.5-2.0. Lower concentrations of total nitrate and [Al]/[F] molar ratios may still have acceptable performance but were not tested in this study. Loading and washing Pu losses should be relatively low (<1%) for resin loading of up to 60 g Pu/L. Loading above 60 g Pu/L resin is possible, but Pu wash losses will increase such that 10-20% of the additional Pu fed may not be retained by the resin as the resin loading approaches 80 g Pu/L resin.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Load Balancing Scientific Applications

The largest supercomputers have millions of independent processors, and concurrency levels are rapidly increasing. For ideal efficiency, developers of the simulations that run on these machines must ensure that computational work is evenly balanced among processors. Assigning work evenly is challenging because many large modern parallel codes simulate behavior of physical systems that evolve over time, and their workloads change over time. Furthermore, the cost of imbalanced load increases with scale because most large-scale scientific simulations today use a Single Program Multiple Data (SPMD) parallel programming model, and an increasing number of processors will wait for the slowest one at the synchronization points. To address load imbalance, many large-scale parallel applications use dynamic load balance algorithms to redistribute work evenly. The research objective of this dissertation is to develop methods to decide when and how to load balance the application, and to balance it effectively and affordably. We measure and evaluate the computational load of the application, and develop strategies to decide when and how to correct the imbalance. Depending on the simulation, a fast, local load balance algorithm may be suitable, or a more sophisticated and expensive algorithm may be required. We developed a model for comparison of load balance algorithms for a specific state of the simulation that enables the selection of a balancing algorithm that will minimize overall runtime.

97 MATHEMATICS AND COMPUTING↗

Research, Development and Demonstration of Peak Load Reduction on Distribution Feeders Using Distributed Energy Resources for the City of Fort Collins

This project titled “Research, Development and Demonstration of Peak Load Reduction on Distribution Feeders Using Distributed Energy Resources for the City of Fort Collins” evolved in response to the Department of Energy’s (DOE) Funding Opportunity Announcement (FOA) Number DE-PS26-07NT43119. Also referred to as the Fort Collins Renewable and Distributed System Integration (RDSI) Project, the effort was undertaken by a diverse group of local government, higher education and business organizations; and was driven by three overarching goals: I. Fulfill the requirements of the DOE FOA’s Area of Interest 2: Renewable and Distributed System Integration; most notably, to demonstrate the ability to reduce electric system distribution feeder peak load by 15% or more through the coordinated use of Distributed Energy Resources (DER). II. Advance the expertise, technologies and infrastructure necessary to support the long term vision of the Fort Collins Zero Energy District (FortZED) and move towards creating a zero energy district in the Fort Collins “Old Town” area. III. Further the goals of the City of Fort Collins Energy Policy, including the development of a Smart Grid-enabled distribution system in Fort Collins, expanded use of renewable energy, increased energy conservation, and peak load reduction. Through the collaborative efforts of the partner organizations, the Fort Collins RDSI project was successful in achieving all three of these goals. This report is organized into two distinct sections corresponding to the two phases of the project: • Part 1: Feeder Peak Load Reduction and the FortZED Initiative. • Part 2: Forming and Operating Utility Microgrids and Managing Load and Production Variability The original project scope addressed the Part 1 feeder peak load reduction. That work took place from 2009 through 2011 and was largely complete when the project scope was amended to include a demonstration of microgrid operations. While leveraging the assets, partner relationships, and lessons learned from Part 1, Part 2 was managed and executed as a distinct and substantially independent sub-project during the spring and summer of 2013. Both Parts 1 and 2 of the overall RDSI project can be viewed as cohesive stand-alone bodies of work and are presented as such within this report. In addition to the narratives, this document includes two Appendices that were compiled to supplement information about the various aspects of activities performed during Parts 1 and 2 of the project. Moreover, these Appendices are organized (as outlined below) so as to directly relate to the narratives in Part 1 and 2 of this report. • Appendix - Part 1: describes the roles of each project participant in regards to the feeder peak load reduction effort, and • Appendix - Part 2: deals with the microgrid research/demonstration.

14 SOLAR ENERGY↗

Load Composition Model Workflow (BPA TIP-371 Deliverable 1A)

This project is funded under Bonneville Power Administration (BPA) Strategic Partnership Project (SPP) 17-005 between BPA and SLAC National Accelerator Laboratory. The project in a BPA Technology Improvement Project (TIP) that builds on and validates the Composite Load Model developed by the Western Electric Coordinating Council's (WECC) Load Modeling Task Force (LMTF). The composite load model is used by the WECC Modeling and Validation Work Group to study the stability and security of the western electricity interconnection. The work includes development of load composition data sets, collection of load disturbance data, and model development and validation. This work supports reliable and economic operation of the power system. This report was produced for Deliverable 1A of the BPA TIP-371 Project entitled \TIP 371: Advancing the Load Composition Model". The deliverable documents the proposed work ow for the Composite Load Model, which provides the basis for the instrumentation, data acquisition, analysis and data dissemination activities addressed by later phases of the project.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordination and Control of Flexible Building Loads for Renewable Integration; Demonstrations using VOLTTRON

Renewable energy resources such as wind and solar power have a high degree of uncertainty. Large-scale integration of these variable generation sources into the grid is a big challenge for power system operators. Buildings, in which we live and work, consume about 75% of the total electricity in the United States. They also have a large capacity of power flexibility due to their massive thermal capacitance. Therefore, they present a great opportunity to help the grid to manage power balance. In this report, we study coordination and control of flexible building loads for renewable integration. We first present the motivation and background, and conduct a literature review on building-to-grid integration. We also compile a catalog of flexible building loads that have great potential for renewable integration, and discuss their characteristics. We next collect solar generation data from a photovoltaic panel on Pacific Northwest National Laboratory campus, and conduct data analysis to study their characteristics. We find that solar generation output has a strong uncertainty, and the uncertainty occurs at almost all time scales. Additional data from other sources are also used to verify our study. We propose two transactive coordination strategies to manage flexible building loads for renewable integration. We prove the theories that support the two transactive coordination strategies and discuss their pros and cons. In this report, we select three types of flexible building loads—air-handling unit, rooftop unit, and a population of WHs—for which we demonstrate control of the flexible load to track a dispatch signal (e.g., renewable generation fluctuation) using experiment, simulation, or hardware-in-the-loop study. More specifically, we present the system description, model identification, controller design, test bed setup, and experiment results for each demonstration. We show that coordination and control of flexible loads has a great potential to integrate variable generation sources. The flexible loads can successfully track a power dispatch signal from the coordinator, while having little impact on the quality of service to the end-users.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thickness and Load-Deflection of Direct Ink Write (DIW) Polymer Parts

Parts were made by direct ink write (DIW)using a developmental 50 A durometer ink. Thickness and load-deflection were measured at four test locations on each part.Original thickness was measured using a digital thickness gauge (Checkline MTG-DX) with a 28.7-mm-diameter foot applying 0.6 kPa stress. Load-deflection was measured using an Instron 5966 equipped with a 10 kN load cell, 28.68-mm-diameter fixed lower platen, and a 50-mm-diameter spherical seat upper platen. Three load-unload cycles to a compressed thickness of 0.85 mm were performed at a test speed of 1.26 mm/min. The compressed thickness was corrected to account for instrument compliance. Original thickness is given in Table 1. Load-deflection curves(engineering stress vs. compressed thickness)are shown in Figure1. Load-deflection data(uncorrected thickness, compliance-corrected thickness, load, and engineering stress) is provided in Tables 2-4.

36 MATERIALS SCIENCE↗

Load Test of Alum-a-Lift Serial No. 33053261

An Alum-A-Lift A800CSPD-60 (Lift) was procured to support mechanical testing of programmatic equipment. This testing will take place within the Bldg. 131 Hi Bay. The design of the Lift procured for the purposes at LLNL was a modification of a machine that had previously been engineered and sold by Alum-a-Lift, see Fig. 1. The modification was to shorten the boom from a 56 in. length to a 28 in. length. The modified design is illustrated in Fig. 2. The Lift was fabricated and shipped to LLNL, received ~ June 2022. Upon arrival, it was successfully evaluated for “no-load” performance capability. Upon inspection of the documentation provided by Alum-a-Lift, it was noted that the load test was performed to qualify the machine for a lifting capacity of 200 lb. The LLNL requirement was that the capacity of the machine be 400 lb. Conversations with the vendor, Alum-A-Lift, followed this discovery. Rather than send the machine back to the vendor for load testing, discussions concurred that LLNL would load test the machine and Alum-A-Lift would provide the relevant load test placard to be placed on the machine subsequent to the successful load test. This MESN provides documentation of the load test to qualify the Alum-a-Lift to its’ rated capacity of 400 lb.

42 ENGINEERING↗

Radioisotope Power System Cask Trailer Chiller Low Heat Load Study

This report documents the study of the Radioisotope Thermoelectric Generator Transport System (RTGTS) chillers capability to transport a Radioisotope Power System (RPS) with low heat loads in the cask. Tests of the RTGTS chillers included setting the glycol/water (coolant) temperature to a control set point of 40° and 60°F while applying heat loads ranging from 2500 to 0 W heat load. The tests performed showed that the chiller systems could handle the entire range of heat loads. However, a noise/vibration started to occur when the set point was 60°F with low heat loads. Three recommended changes to the RTGTS chillers are recommended with varying implementation windows. The first is an operational change that can be implemented immediately. The RTGTS chillers should have a set point of 40°F when transporting an RPS less than 1500 W. The second is a short-term change (within the next two years) augmenting RPS heat by utilizing one RTGTS onboard heater (2500 W) while transporting an RPS with less than 1500 W which will also require a change to the Instrument and Data Acquisition System (IDAS) to allow monitoring and possible control of power to the onboard heaters. However, if the heater does fail during transport, no emergency actions or immediate repairs will be required due to the chillers’ ability to handle low heat loads. Running a 2500 W heater when transporting low heat loads aids in prolonging the life of the chillers. The remaining recommended long-term change is to replace the current chillers with a new portable or permanently installed chiller system in the next five to ten years. This time frame takes advantage of the proven reliability and durability of the current chillers while the new chillers are phased in and proven to the RPS program.

42 ENGINEERING↗

Characterizing IHE Response to Multiple Shock Loading

The response of high explosives to shock loading is traditionally measured with a steady loading pressure. In many accident scenarios involving fragment impact, however, a loading duration that is shorter than the build up to detonation may occur. Fragments passing through multiple materials before reaching a high explosive charge may produce loading that is comprised of more than one shock wave. Additionally, the build up to detonation in high explosive corner turning loads the explosive a short duration pressure pulse, since rarefactions can often rapidly overtake the reactive wave. For these reasons, we have studied the response of the insensitive high explosive (IHE) materials PBX 9502 and LX-17 to complex loadings of varied intensity and duration. We refer to a single loading of limited duration as a “thin pulse”, whereas more complex scenarios were studied with an impactor that produces a double shock in the explosive. The following report presents experimental data and analyses of thin pulse shock initiation and double shock experiments designed to guide development of models of Insensitive High Explosives (IHEs) under controlled one-dimensional conditions relevant to accident scenarios and corner turning. Thin pulse shock initiation data on PBX 9502 and LX-17 were obtained under varied pulse duration, pressed density, and temperature conditions in order to probe various parameters essential for the development of a physics-based Cheetah reactive flow hotspot model. In situ pressure gauges provide insight into the degree of reaction in the explosive that are not obtainable with optical PDV measurements or distance measurements such as run to detonation. Double shock data was obtained to inform a Composition Aware Cheetah model which can be applied to any TATB-based IHEs. This model supports efforts to find a new IHE formulation and potentially incorporate new binders into IHE formulations. Simulations of each experiment are included to demonstrate the utility of these focused experiments to developing models of HE behavior. One-dimensional gas gun experiments are essential for characterizing shocked HE behavior and informing HE models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimization of Canister Loading Patterns in Dual Purpose Canisters for Criticality Suppression

This report documents work performed in support of the US Department of Energy Office of Nuclear Energy (NE) Spent Fuel and Waste Disposition, Spent Fuel and Waste Science and Technology, under work breakdown structure element 1.08.01.03.05, “Direct Disposal of Dual Purpose Canisters.” In particular, this report fulfills milestone M3SF-22PN010305094, “Application of AI/ML techniques to optimize DPC loading,” within work package SF-22PN01030509, “Direct Disposal of Dual Purpose Canisters - PNNL.” This report continues the process of examining the potential for using loading optimization as a disposal criticality suppression technique. This latest update to the report added: 1. A validation of the artificial neural network (ANN) reactivity prediction tool against as-loaded dual-purpose canisters from the UNF-ST&DARDS database 2. Refinement of the algorithm to incorporate an additional DPC design to improve the predictions 3. Investigation of a storage and transportation focused loading optimization algorithm. A key result from this year’s work is that the ANN performance was significantly improved by including the additional model for the NUHOMS canisters and it is apparent that fuel type specific modeling considerations should be incorporated into the ANN in future work. The GRASP-enabled adaptive multi-objective memetic algorithm with partial clustering (GAMMA-PC) algorithm was evaluated as a tool for storage and transportation oriented optimization. The GAMMA-PC optimization routine considers decay heat at loading, the time between loading and when the canister is eligible for transportation and minimizes the number of casks loaded. Future work will develop a dose minimization optimization routine.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Loading Path Dependence of Forming Limit Diagram of a TRIP800 Steel

In this paper, the microstructure-based finite element modeling method is used in investigating the loading path dependence of formability of transformation induced plasticity (TRIP) steels. For this purpose, the effects of different loading path on the forming limit diagrams (FLD) of TRIP steels are qualitatively examined using the representative volume element (RVE) of a commercial TRIP800 steel. First, the modeling method was introduced, where a combined isotropic/kinematic hardening rule is adopted for the constituent phases in order to rightly describe the cyclic deformation behaviors of TRIP steels during the forming process with combined loading paths which may include the unloading between the two consecutive loadings. Material parameters for the constituent phases remained the same as those in the authors’ previous study [1] except for some adjustments for the martensite phase due to the introduction of the new combined hardening rule. Based on the new material parameters and new hardening rule, the predicted deformation behaviors of the TRIP800 steel show quite similar qualitative trends to those reported in other experimental works. Pseudo-forming limit strain diagrams (Pseudo-FLD) for the TRIP800 steel were, then, obtained for various loading paths. The computational results show that, similar to other single phase materials, the TRIP800 steel shows very sensitive loading path dependence in the strain-based forming limit diagrams (strain-FLD), but does not in the stress-based forming limit diagrams (stress-FLD), and that the phase transformation does not have significant effects on the FLD for the TRIP800 steel. From the observations in this study, the current modeling methods can be used in examining the qualitative trends of FLD of TRIP steels under different loading paths/prestrains.

Forming limit diagram↗

Fuel Effects on Advanced Compression Ignition Load Limits

In order to increase the efficiency of light-duty gasoline engines, the Co-Optimization of Fuels and Engines (Co-Optima) initiative from the U.S. Department of Energy is investigating multi-mode combustion strategies. Multi-mode combustion can be describe as using conventional spark-ignited combustion at high loads, and at the part-load operating conditions, various advanced compression ignition (ACI) strategies are being investigated to increase efficiency. Of particular interest to the Co-Optima initiative is the extent to which optimal fuel properties and compositions can enable higher efficiency ACI combustion over larger portions of the operating map. Extending the speed-load range of these ACI modes can enable greater part-load efficiency improvements for multi-mode combustion strategies. In this manuscript, we investigate fuel effects for six different fuels, including four with a research octane number (RON) of 98 and differing fuel chemistries, iso-octane, and a market representative E10 fuel, on the load limits for two different ACI strategies: spark-assisted compression ignition (SACI) and partial fuel stratification-gasoline compression ignition (PFS-GCI) operation. Experimental results show that limits to intake boosting limit high load operation for most fuels, but high smoke emissions for high particulate matter index (PMI) fuels under SACI conditions could also be a limitation. Contrastingly, low load is limited by combustion efficiency, but these effects have more pronounced variation with fuel chemistry for PFS-GCI than with SACI. Additional, distinct effects affecting autoignition timing and peak heat release at higher speeds were identified for fuels having different low temperature heat release (LTHR) propensities for both ACI modes.

33 ADVANCED PROPULSION SYSTEMS↗

Static and dynamic load measurements in aerospace decelerator canopy fabrics with metal foil strain gages.

A test program was conducted to determine the feasibility of using conventional metal foil strain gages to measure load-time relationships on thin fabric membranes while these membranes were loaded under simulated aerodynamic decelerator conditions. Uniaxial and biaxial tests were made at fabric strain levels up to about 10%. Loadings were made both statically and dynamically, with the fastest load time being 0.015 second for zero to full load on uniaxial test specimens. For the biaxial tests, plane strain conditions were assumed, and by using experimentally determined strain-load relationships, principal loads were determined from the perpendicularly oriented strain-gage pairs. Although the complex stress-strain behavior of decelerator fabrics prevents the attainment of normally expected strain-gage accuracy, utilization of the techniques described can lead to meaningful measurements for the decelerator stress analyst.

Hoffman, I. S.↗

Pneumatic load compensating or controlling system

A pneumatic load compensating or controlling system for restraining a load with a predetermined force or applying a predetermined force to the load is described; it includes a source of pressurized air, a one-way pneumatic actuator operatively connected to a load, and a fluid conduit fluidically connecting the actuator with the source of pressurized air. The actuator is of the piston and cylinder type, and the end of the fluid conduit is connected to the upper or lower portion of the cylinder whereby the actuator alternatively and selectively restrains the load with a predetermined force or apply a predetermined force to the load. Pressure regulators are included within the system for variably selectively adjusting the pressurized fluid to predetermined values as desired or required; a pressure amplifier is included within the system for multiplying the pressurized values so as to achieve greater load forces. An accumulator is incorporated within the system as a failsafe operating mechanism, and visual and aural alarm devices, operatively associated with pressure detecting apparatus, readily indicate the proper or improper functioning of the system.

Rogers, J. R.↗

Dynamic blade loading in the ERDA/NASA 100 kW and 200 kW wind turbines

Dynamic blade loads, including aerodynamic, gravitational, and inertial effects, are presented for two large horizontal-axis wind turbines: the ERDA-NASA 100 kW Mod-0 and 200 kw Mod-0A wind power systems. Calculated and measured loads are compared for an experimental Mod-0 machine in operation. Predicted blade loads are also given for the higher power Mod-0A wind turbine now being assembled for operation as part of a municipal power plant. Two major structural modifications have been made to the Mod-0 wind turbine for the purpose of reducing blade loads. A stairway within the truss tower was removed to reduce the impulsive aerodynamic loading caused by the tower wake on the downwind rotor blades. Also, the torsional stiffness of the yaw drive mechanism connecting the turbine nacelle to the tower was doubled to reduce rotor-tower interaction loads. Measured reductions in load obtained by means of these two modifications equaled or exceeded predictions.

Spera, D. A.↗

Voyager design and flight loads comparison

Estimates of flight loads for Voyager 1 and Voyager 2 are summarized. These member loads are obtained by using the measured flight accelerations at the launch vehicle/spacecraft interface as forcing functions for the Voyager mathematical model. The flight loads are compared to the Voyager design loads obtained from the shock spectra/impedance method and to the loads obtained using space vehicle transient loads analysis. Finally, based on these data, an assessment of the shock spectra/impedance loads method used for Voyager is presented.

Chen, J. C.↗