Search NASA⌕ Search

SEARCH · Search NASA

Results for “network monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Spatio-Temporal Variability of Groundwater Storage in India

Groundwater level measurements from 3907 monitoring wells, distributed within 22 major river basins of India, are assessed to characterize their spatial and temporal variability. Ground water storage (GWS) anomalies (relative to the long-term mean) exhibit strong seasonality, with annual maxima observed during the monsoon season and minima during pre-monsoon season. Spatial variability of GWS anomalies increases with the extent of measurements, following the power law relationship, i.e., log-(spatial variability) is linearly dependent on log-(spatial extent).In addition, the impact of well spacing on spatial variability and the power law relationship is investigated. We found that the mean GWS anomaly sampled at a 0.25 degree grid scale closes to unweighted average over all wells. The absolute error corresponding to each basin grows with increasing scale, i.e., from 0.25 degree to 1 degree. It was observed that small changes in extent could create very large changes in spatial variability at large grid scales. Spatial variability of GWS anomaly has been found to vary with climatic conditions. To our knowledge, this is the first study of the effects of well spacing on groundwater spatial variability. The results may be useful for interpreting large scale groundwater variations from unevenly spaced or sparse groundwater well observations or for siting and prioritizing wells in a network for groundwater management. The output of this study could be used to maintain a cost effective groundwater monitoring network in the study region and the approach can also be used in other parts of the globe.

Groundwater monitoring↗

Cyber-Physical Smart Light Control System Integration with Smart Grid using Zigbee

This paper presents a hardware-in-the-loop cyber-physical system architecture design to monitor and control smart lights connected to the active distribution grid. The architecture uses Zigbee-based (IEEE 802.15.4) wireless sensor networks and publish-subscribe architecture to exchange monitoring and control signals between smart-light actuators (SLAs) and a smart-light central controller (SLCC). Each SLA integrated into a smart light consists of a Zigbee-based endpoint module to send and receive signals to and from the SLCC. The SLCC consists of a Zigbee-based coordinator module, which further exchanges the monitoring and control signals with the active distribution management system over the TCP/IP communication network. The monitoring signals from the SLAs include light status, brightness level, voltage, current, and power data, whereas, the control signals to the SLAs include light intensity, turn ON, turn OFF, standby, and default settings. We have used our existing hardware-in-the-loop (HIL) cyber-physical system (CPS) security SCADA testbed to process signals received from the SLCC and respond suitable control signals based on the smart light schedule requirements, system operation, and active distribution grid dynamic characteristics. We have integrated the proposed cyber-physical smart light control system (CPSLCS) testbed to our existing HIL CPS SCADA testbed. We use the integrated testbed to demonstrate the efficacy of the proposed algorithm by real-time performance and latency between the SLCC and SLAs. The experiments demonstrated significant results by 100% realtime performance and low latency while exchanging data between the SLCC and SLAs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Using SF 6 and Xe to Monitor Gas Migration Through Explosion-Generated Fracture Networks

Here we describe a field study where tracer gas was injected into a subsurface cavity created by a small chemical explosion beneath the water table. The main objective of the study is to compare the migration of sulfur hexafluoride (SF 6 ) and xenon (Xe) through an explosion-generated fracture network and to study the influence of ground water on gas transport. A mixture of tracer gases (50% of SF 6 and 50% of Xe) was injected on 31 October 2018 and gas sampling continued until 8 November 2018. We observe similar trends in SF 6 and Xe concentrations at four ground surface sampling sites. The changes in the SF 6 /Xe ratios with time show that more SF 6 than Xe is observed during the barometric pressure lows when the absolute measured concentrations are highest. Conversely, the ratio SF 6 /Xe is less than 1 during the high-pressure intervals when absolute measured concentrations are low. The results of the experiment suggest that during barometric pressure lows the tracer is migrating to the surface primarily by advective gas phase transport, whereas during barometric pressure highs, advection is suppressed and near-surface evaporation of interstitial pore fluid with tracer dissolved in it becomes more important. Thus, the results of the experiment show that the gas concentrations at the surface are controlled by the combined effects of the gas dissolution into pore water and the barometric pressure fluctuations.

58 GEOSCIENCES↗

Ensemble Kalman Filter for Dynamic State Estimation of Power Grids Stochastically Driven by Time-correlated Mechanical Input Power

State and parameter estimation of power transmission networks is important for monitoring power grid operating conditions and analyzing transient stability. Wind power generation depends on fluctuating input power levels, which are correlated in time and contribute to uncertainty in turbine dynamical models. The ensemble Kalman filter (EnKF), a standard state estimation technique, uses a deterministic forecast and does not explicitly model time-correlated noise in parameters such as mechanical input power. However, this uncertainty affects the probability of fault-induced transient instability and increased prediction bias. Here a novel approach is to model input power noise with time-correlated stochastic fluctuations, and integrate them with the network dynamics during the forecast. While the EnKF has been used to calibrate constant parameters in turbine dynamical models, the calibration of a statistical model for a time-correlated parameter has not been investigated. In this study, twin experiments on a standard transmission network test case are used to validate our time-correlated noise model framework for state estimation of unsteady operating conditions and transient stability analysis, and a methodology is proposed for the inference of the mechanical input power time-correlation length parameter using time-series data from PMUs monitoring power dynamics at generator buses.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sampling Approaches for Multi-Domain Internet Performance Measurement Infrastructures

The next-generation of high-performance networks being developed in DOE communities are critical for supporting current and emerging data-intensive science applications. The goal of this project is to investigate multi-domain network status sampling techniques and tools to measure/analyze performance, and thereby provide “network awareness” to end-users and network operators in DOE communities. We leverage the infrastructure and datasets available through perfSONAR, which is a multi-domain measurement framework that has been widely deployed in high-performance computing and networking communities; the DOE community is a core developer and the largest adopter of perfSONAR. Our investigations include development of semantic scheduling algorithms, measurement federation policies, and tools to sample multi-domain and multi-layer network status within perfSONAR deployments. We validate our algorithms and policies with end-to-end measurement analysis tools for various monitoring objectives such as network weather forecasting, anomaly detection, and fault-diagnosis. In addition, we develop a multi-domain architecture for an enterprise-specific perfSONAR deployment that can implement monitoring-objective based sampling and that adheres to any domain-specific measurement policies.

97 MATHEMATICS AND COMPUTING↗

Unsupervised learning from three-component accelerometer data to monitor the spatiotemporal evolution of meso-scale hydraulic fractures

Enhanced geothermal systems can provide a substantial share of the global energy demand. There exist several hurdles in the engineering implementations of such geothermal systems. One such hurdle is the accurate monitoring of the fracture networks created in subsurface through hydraulic stimulation of these systems. Micro seismicity associated with the stimulation is the primary means to locate the event hypocenters for estimating the stimulated rock volume. Existing methods for location the hypocenters are restricted to only the highest amplitude impulsive signals that are simultaneously detected on several sensors. Consequently, a large portion (usually ~99%) of the measurements are left unused. In this paper, an unsupervised manifold-approximation followed by clustering of 3-component accelerometer data is used to analyze the seismicity recorded on a monitoring well. With this method, a larger portion of the measured signal is used for the monitoring of the hydraulic fracture network. We analyze the EGS Collab experiment 1 microseismic data, recorded at the Sanford Underground Research Facility, South Dakota. Using the data from a single three-component accelerometer, the polarization features viz. Azimuth, incidence, rectilinearity, and planarity are used as inputs for the unsupervised manifold approximation followed by clustering. Our study shows that density-based clusters in the projected 3D space correspond to distinct types of hydraulically fractured zones around the injection point. Finally, we show that the temporal evolution of these clusters can be used to track fracture creation and propagation.

58 GEOSCIENCES↗

Monitor and Control of the Deep-Space network via Secure Web

(view graph) NASA lead center for robotic space exploration. Operating division of Caltech/Jet Propulsion Laboratory. Current missions, Voyagers, Galileo, Pathfinder, Global Surveyor. Upcoming missions, Cassini, Mars and New Millennium.

Deep-Space Network communications NCP Data Managem↗

Multi-Year Movements of Blacknose, Finetooth, & Sharpnose Sharks in the US South Atlantic Based on Monitoring Within a Regional-Scale Acoustic Telemetry Network

Despite their numerical abundance and economic value, the behavior of many small coastal sharks in the US South Atlantic has been only coarsely described. Here we present movement summaries for blacknose (Carcharhinus acronotus), finetooth (C. isodon), and Atlantic sharpnose shark (Rhizoprionodon terraenovae) as they travelled through a regional-scale acoustic telemetry network, offering direct comparisons of habitat utilization, site fidelity, and the extent and timing of coastal migrations. From 2013-2016, 165 total sharks were implanted with acoustic transmitters at Cape Canaveral, Florida, and tracked up to four years. While blacknose sharks were common off east Florida year-round, finetooth sharks were most abundant winter through early spring and sharpnose sharks summer through fall. Blacknose sharks also moved more slowly (mean 0.8 kilometers per hour) and had the broadest depth preferences, while finetooth sharks were strongly shore-associated and sharpnose preferred proportionally deeper waters. All species exhibited low site fidelity when at Cape Canaveral, remaining at the same site for more than 1 hour on average, even when associated with deeper hard-bottom sites. Most finetooth and many blacknose undertook spring migrations as far as Virginia and North Carolina, respectively, before returning to east Florida each winter. Sharpnose also made regular northward movements that were not as obviously seasonally-driven. Multiple individuals of all species, particularly females, returned briefly south to Cape Canaveral in mid-summer, illustrating that coastal migrations in these species are more akin to seasonal expansions of their geographic ranges as opposed to a synchronized shift of the entire population along the coast.

Reyier, Eric↗

Machine learning analysis reveals relationship between pomacentrid calls and environmental cues

Sound production rates of fishes can be used as an indicator for coral reef health, providing an opportunity to utilize long-term acoustic recordings to assess environmental change. As acoustic datasets become more common, computational techniques need to be developed to facilitate analysis of the massive data files produced by long-term monitoring. Machine learning techniques demonstrate an advantage in the identification of fish sounds over manual sampling approaches. Here we evaluated the ability of convolutional neural networks to identify and monitor call patterns for pomacentrids (damselfishes) in a tropical reef region of the western Pacific. A stationary hydrophone was deployed for 39 mo (2014-2018) in the National Park of American Samoa to continuously record the local marine acoustic environment. A neural network was trained—achieving 94% identification accuracy of pomacentrids—to demonstrate the applicability of machine learning in fish acoustics and ecology. The distribution of sound production was found to vary on diel and interannual timescales. Additionally, the distribution of sound production was correlated with wind speed, water temperature, tidal amplitude, and sound pressure level. This research has broad implications for state-of-the-art acoustic analysis and promises to be an efficient, scalable asset for ecological research, environmental monitoring, and conservation planning.

59 BASIC BIOLOGICAL SCIENCES↗

Surface convergence techniques and the prediction of lightning at Kennedy Space Center

This study compares two convergence techniques leading to the prediction of convective development and lightning: the area-averaged technique and a convergence cell approach. The area-averaged technique uses total area divergence across the network to identify the potential for new, local thunderstorm growth. A threshold of 75 x 10 to the -6th/s change in divergence is used to define a convergence event, and a separation of 30 minutes between flashes defines a lightning event. Convergence-lightning life cycles are found to be on the order of 1 hour from beginning convergence to first flash, and more than 2 hours from beginning convergence to the end of lightning. The convergence cell technique measures the strength of the convergence cell, which in turn leads to vertical development. Therefore, the likely lightning location and intensity can be ascertained in the larger network. Several cells can be monitored in the recently expanded Kennedy Space Center forecast network at the same time.

Watson, Andrew I.↗

Rapid deployable global sensing hazard alert system

A rapid deployable global sensing hazard alert system and associated methods of operation are provided. An exemplary system includes a central command, a wireless backhaul network, and a remote monitoring unit. The remote monitoring unit can include a positioning system configured to determine a position of the remote monitoring unit based on one or more signals received from one or more satellites located in Low Earth Orbit. The wireless backhaul network can provide bidirectional communication capability independent of cellular telecommunication networks and the Internet. An exemplary method includes instructing at least one of a plurality of remote monitoring units to provide an alert based at least in part on a location of a hazard and a plurality of positions respectively associated with the plurality of remote monitoring units.

97 MATHEMATICS AND COMPUTING↗

Architecture and Methods for Substation SCADA Cybersecurity: Best Practices

There are over 3000 electricity providers in the United States, encompassing investor and publicly owned utilities as well as electric cooperatives. There has been ongoing trends to increasingly automate and provide remote control and monitoring of electric energy delivery systems. The deployment of computer network technologies has increased the efficiency and reliability of electric power infrastructure. However, the increased use of digital communications has also increased the vulnerability to malicious cyber attacks [1]. In 2004 the National Research Councils (National Academies) formed a committee of specialists to address these vulnerabilities and propose possible solutions with an objective to prioritize the R&D needs for developing countermeasures. The committee addressed many potential concerns in the electric power delivery system and classified them based upon different criteria and presented recommendations to minimize the gap between the academic research directions and the needs of the electric utility industry. The complexity and diversity of the electric power delivery system in the U.S. has opened many ports for attackers and intruders [1]. This complexity and diversity is attributed to the fact that power delivery system is a network of substations, transmission and distribution lines, sub-networks of controlling, sensing and monitoring units, and human operator involvement for running the system [1]. Accordingly, any incident such as the occurrence of a fault or disturbance in this complex network cannot be deferred and should be resolved within an order of milliseconds, otherwise there is risk of large-scale outages similar to the occurrences in India and the U.S. in 2003 [2]. There are three main vulnerabilities in supervisory control and data acquisition (SCADA) systems commonly identified—physical vulnerability, cyber vulnerability and personal vulnerability [1]. In terms of cyber threats, SCADA systems are the most critical elements in the electric power grid in the U.S. Unauthorized access to a SCADA system could enable/disable unexpected equipment (such as disable the protection system or a circuit breaker) which could cause large scale disruptions of electric power delivery. This paper provides an overview of power system SCADA technologies in transmission substations (Section 2) and summarizes the best practices for implementing a cyber security program. After introducing SCADA system operations in Section 2, a description of the security challenges for SCADA systems is presented in Section 3. In Section 4, NECRC Critical Infrastructure Protection standards CIP-002 through CIP-009 are summarized. An overview of industry best practices is presented in Section 5.

97 MATHEMATICS AND COMPUTING↗

Defining Detection Limits for Continuous Monitoring Systems for Methane Emissions at Oil and Gas Facilities

Networks of fixed-point continuous monitoring systems are becoming widely used in the detection and quantification of methane emissions from oil and gas facilities in the United States. Regulatory agencies and operators are developing performance metrics for these systems, such as minimum detection limits. Performance characteristics, such as minimum detection limits, would ideally be expressed in emission rate units; however, performance parameters such as detection limits for a continuous monitoring system (CMS) will depend on meteorological conditions, the characteristics of emissions at the site where the CMS is deployed, the positioning of CMS devices in relation to the emission sources, and the amount of time allowed for the CMS to detect an emission source. This means that certifying the performance of a CMS will require test protocols with well-defined emission rates and durations; initial protocols are now being used in field tests. Field testing results will vary, however, depending on meteorological conditions and the time allowed for detection. This work demonstrates methods for evaluating CMS performance characteristics using dispersion modeling and defines an approach for normalizing test results to standard meteorological conditions using dispersion modeling.

Chen, Qining (ORCID:0000000316908091)↗

EVSE Cybersecurity and Resilience

Consequence-driven Cybersecurity Analysis for Extreme Fast Charging Electric Vehicle Infrastructure Electric vehicle (EV) development and associated charging infrastructure are expected to advance rapidly. Thirty percent of all global vehicle sales may be EVs and hybrid EVs by 2025, and they will rely on increasingly sophisticated strategies for grid integration. Next-generation EV charging infrastructure is expected to include interconnected renewable resources, such as photovoltaic (PV) arrays and battery storage systems, along with grid-edge devices. Although distributed energy resources (DERs) are useful in several ways, such as peak shaving at high demand times and backup supply for added resilience, the integration of vehicle charging and DERs could create more avenues for cyberattack. Physical and/or remote access to EV charging station components, including charge ports, power electronics, controllers, and local generation (e.g., PV and energy storage) could be paths to cause power fluctuations, leading to altered operations at the charging station, escalated privileges to administrative systems, exfiltration of financial information (including personally identifiable information), and reduced grid stability. One compromised EV supply equipment component can open the door to a variety of exploitable vulnerabilities. Cloud computing and mobile application control have the potential to expand the threat surface to non-repudiation and firmware integrity challenges. Vendor clouds have access to hundreds of chargers, and if compromised, can scale the attack surface exponentially. The high power and voltage levels of xFC infrastructure (e.g., 400 kW at 1000- V DC) increase the hazards and ability to impact the grid and vehicles more than lower-power charging systems. Legacy communications systems and protocols could also put EV infrastructure at risk of cyberattacks requiring a robust patch management process. Communications networks link EVs and chargers to several stakeholders - including charging station operators, grid operators, vendors/manufacturers, and aggregators - who have both physical and network access to share information for control, monitoring, and analytics. Information in these networks that is vulnerable to compromise includes the state of charge, charging duration, payment information, electricity price, and load control. Analyzing and prioritizing these interconnections risks could help address cybersecurity related to data leakage and manipulation.

charging↗