At least 793 records · Page 44

Performance analysis of a noncoherently combined large aperture optical heterodyne receiver

The performance of a noncoherently combined, multiple-mirror heterodyne receiver is analyzed. It is shown that in the absence of atmospheric turbulence, the performance of the noncoherently combined receiver is inferior to that of a monolithic, diffraction-limited receiver with equivalent aperture area. However, when atmospheric turbulence is taken into consideration, the efficiency of a monolithic aperture heterodyne receiver is limited by the phase coherence length of the atmosphere and generally does not improve with increasing aperture size. In constrast, the performance of a noncoherently combined system improves with an increasing number of receivers. Consequently, given a fixed collecting area, the noncoherently combined system can offer superior performance. The performance of the noncoherently combined heterodyne receiver is studied by analyzing the combining loss of the receiver SNR. It is shown that, given the collecting area, the performance of the combined receiver is optimized when the diameter of each of the individual receivers is on the order of the phase coherence length gamma sub 0 of the atmospheric turbulence.

Chen, C.-C.↗

Performance analysis of a noncoherently combined large aperture optical heterodyne receiver

The performance of a noncoherently combined (NC) multiple-mirror heterodyne receiver is analyzed. With no atmospheric turbulence (AT), the performance of the NC receiver is shown to the inferior to that of a monolithic diffraction-limited receiver with equivalent aperture area. When AT is taken into consideration, however, the efficiency of a monolithic receiver is limited by the phase coherence length of the atmosphere, and generally does not improve with increasing aperture size. In contrast, the performance of an NC system improves with an increasing number of receivers. Consequently, given a fixed collecting area, the NC system can offer superior performance. The performance of the NC heterodyne receiver is studied by analyzing the combining loss of the receiver SNR. It is shown that, given a constant collecting area, the performance of the NC receiver is optimized when the diameter of each of the individual receivers is on the order of the phase coherence length of the AT.

Chen, Chien-Chung↗

An automated system for the alignment of large area modular solar simulators

A real-time optical alignment and diagnostic system is being assembled for installation at the Space Environment Simulation Laboratory. This system will be used to measure and analyze the performance of optical components, assemblies, and full modules. This information, in turn, is used to align assemblies and modules. The system capability includes such functions as the generation and updating of a catalog, which serves as permanent record, in addition to providing the capability to predict in-chamber performance of optics combinations before they are mounted in the chamber.

Vincent, J. P.↗

Performance of PLL synchronized optical PPM communication systems

Receiver timing synchronization of an optical PPM communication system can be achieved using a phase-locked loop (PLL) if the photodetector output is properly processed. The synchronization performance is shown to improve with increasing signal power and decreasing loop bandwidth. The bit error rate performance of the PLL synchronized PPM system is analyzed and compared to that of the perfectly synchronized system. It is shown that the increase in signal power needed to compensate for the imperfect sychronization is small (less than 0.1 dB) for loop bandwidths less than 0.1 percent of the slot frequency.

Chen, C.-C.↗

Gamma-ray mirror technology for NDA of spent fuel

Direct measurements of gamma rays emitted by fissile material have been proposed as an alternative to measurements of the gamma rays from fission products. From a safeguards applications perspective, direct detection of uranium (U) and plutonium (Pu) K-shell fluorescence emission lines and specific lines from some of their isotopes could lead to improved shipper-receiver difference or input accountability at the start of Pu reprocessing. However, these measurements are difficult to implement when the spent fuel is in the line-of-sight of the detector, as the detector is exposed to high rates dominated by fission product emissions. To overcome the combination of high rates and high background, grazing incidence multilayer mirrors have been proposed as a solution to selectively reflect U and Pu hard X-ray and soft gamma rays in the 90 to 420 keV energy into a high-purity germanium (HPGe) detector shielded from the direct line-of-sight of spent fuel. Several groups demonstrated that K-shell fluorescence lines of U and Pu in spent fuel could be detected with Ge detectors. In the field of hard X-ray optics the performance of reflective multilayer coated reflective optics was demonstrated up to 645 keV at the European Synchrotron Radiation Facility. Initial measurements conducted at Oak Ridge National Laboratory with sealed sources and scoping experiments conducted at the ORNL Irradiated Fuels Examination Laboratory (IFEL) with spent nuclear fuel further demonstrated the pass-band properties of multilayer mirrors for reflecting specific emission lines into 1D and 2D HPGe detectors, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Space infrared telescope facility wide field and diffraction limited array camera (IRAC)

The wide-field and diffraction limited array camera (IRAC) is capable of two-dimensional photometry in either a wide-field or diffraction-limited mode over the wavelength range from 2 to 30 microns with a possible extension to 120 microns. A low-doped indium antimonide detector was developed for 1.8 to 5.0 microns, detectors were tested and optimized for the entire 1.8 to 30 micron range, beamsplitters were developed and tested for the 1.8 to 30 micron range, and tradeoff studies of the camera's optical system performed. Data are presented on the performance of InSb, Si:In, Si:Ga, and Si:Sb array detectors bumpbonded to a multiplexed CMOS readout chip of the source-follower type at SIRTF operating backgrounds (equal to or less than 1 x 10 to the 8th ph/sq cm/sec) and temperature (4 to 12 K). Some results at higher temperatures are also presented for comparison to SIRTF temperature results. Data are also presented on the performance of IRAC beamsplitters at room temperature at both 0 and 45 deg angle of incidence and on the performance of the all-reflecting optical system baselined for the camera.

Fazio, Giovanni G.↗

Use of the sampling theorem to speed up near-field physical optics scattering calculations

Physical optics scattering calculations performed on the DSN 34-m beam-waveguide antennas at Ka-band (32 GHz) require approximately 12 hr of central processing unit time on a Cray Y-MP2 computer. This is excessive in terms of resource utilization and turnaround time. Typically, the calculations involve five surfaces, and the calculations are done two surfaces at a time. The sampling theorem is used to reduce the number of current values that must be calculated over the second surface by performing a physical optics integration over the first surface. The additional number of current values required on the second surface by subsequent physical optics integrations is obtained by interpolation over the original current values. Time improvements on the order of a factor of 2 to 4 were obtained for typical scattering pairs.

Cramer, P. W.↗

Contamination Effects on EUV Optics

During ground-based assembly and upon exposure to the space environment, optical surfaces accumulate both particles and molecular condensibles, inevitably resulting in degradation of optical instrument performance. Currently, this performance degradation (and the resulting end-of-life instrument performance) cannot be predicted with sufficient accuracy using existing software tools. Optical design codes exist to calculate instrument performance, but these codes generally assume uncontaminated optical surfaces. Contamination models exist which predict approximate end-of-life contamination levels, but the optical effects of these contamination levels can not be quantified without detailed information about the optical constants and scattering properties of the contaminant. The problem is particularly pronounced in the extreme ultraviolet (EUV, 300-1,200 A) and far (FUV, 1,200-2,000 A) regimes due to a lack of data and a lack of knowledge of the detailed physical and chemical processes involved. Yet it is in precisely these wavelength regimes that accurate predictions are most important, because EUV/FUV instruments are extremely sensitive to contamination.

Tveekrem, J.↗

Performance Assessment of Portable Optical Particle Spectrometer (POPS)

Accurate representation of atmospheric aerosol properties is a long-standing problem in atmospheric research. Modern pilotless aerial systems provide a new platform for atmospheric in situ measurement. However, small airborne platforms require miniaturized instrumentation due to apparent size, power, and weight limitations. A Portable Optical Particle Spectrometer (POPS) is an emerged instrument to measure ambient aerosol size distribution with high time and size resolution, designed for deployment on a small unmanned aerial system (UAS) or tethered balloon system (TBS) platforms. This study evaluates the performance of a POPS with an upgraded laser heater and additional temperature sensors in the aerosol pathway. POPS maintains its performance under different environmental conditions as long as the laser temperature remains above 25 °C and the aerosol flow temperature inside the optical chamber is 15 °C higher than the ambient temperature. The comparison between POPS and an Ultra-High Sensitivity Aerosol Spectrometer (UHSAS) suggests that the coincidence error is less than 25% when the number concentration is less than 4000 cm –3 . The size distributions measured by both of them remained unaffected up to 15,000 cm –3 . While both instruments’ sizing accuracy is affected by the aerosol chemical composition and morphology, the influence is more profound on the POPS.

47 OTHER INSTRUMENTATION↗

Optical Navigation Attitude Estimation and Calibration Performance Improvement using Outlier Rejection

Spacecraft optical navigation (OpNav) systems process a sequence of images of celestial bodies against a starfield background to estimate the position and velocity of the vehicle. While attitude is sometimes available from an onboard star tracker, it is often desirable to recognize the background stars in the OpNav images to better align the image. While many image processing algorithms exist for finding stars, efficiency and reliability remain key issues in the presence of extended bodies(e.g. the Moon, Earth), especially when attempting to solve the full lost-in-space problem. Some star outliers(stars identified with high residuals)could appear in the camera field of view, however using them in the attitude estimation or camera calibration would lead to less accurate results. Therefore, we require new and robust approaches to remove these outliers before any further processing. The emphasis of the work is on developing a simple and robust iterative technique to detect and reject the outliers which could be found in any frame during the lost in space attitude determination or during the camera calibration. These outliers are determined based on the residuals of the centroids of the detected stars and the corresponding location using the star catalog. If the residuals exceed a predetermined threshold value, the object will be detected as an outlier and will be removed before another attitude determination and calibration iteration is performed. The performance for both attitude determination and on-orbit camera calibration are improved by an almost two-fold increase in accuracy when applying this outlier rejection technique.

OpNav↗

Ultrafast Optical Microscopy of Single Monolayer Molybdenum Disulfide Flakes

We performed ultrafast optical microscopy on single flakes of atomically thin CVD-grown molybdenum disulfide, using non-degenerate femtosecond pump-probe spectroscopy to excite and probe carriers above and below the indirect and direct band gaps. These measurements reveal the influence of layer thickness on carrier dynamics when probing near the band gap. Furthermore, fluence-dependent measurements indicate that carrier relaxation is primarily influenced by surface-related defect and trap states after above-bandgap photoexcitation. Furthermore, the ability to probe femtosecond carrier dynamics in individual flakes can thus give much insight into light-matter interactions in these two-dimensional nanosystems.

36 MATERIALS SCIENCE↗

Bendable X-ray Optics at the ALS: Design, Tuning, Performance and Applications

We review the development at the Advanced Light Source (ALS) of bendable x-ray optics widely used for focusing of beams of soft and hard x-rays. Typically, the focusing is divided in the tangential and sagittal directions into two elliptically cylindrical reflecting elements, the so-called Kirkpatrick-Baez (KB) pair [1]. Because fabrication of elliptical surfaces is complicated, the cost of directly fabricated tangential elliptical cylinders is often prohibitive. This is in contrast to flat optics, that are simpler to manufacture and easier to measure by conventional interferometry. The figure of a flat substrate can be changed by placing torques (couples) at each end. Equal couples form a tangential cylinder, and unequal couples can approximate a tangential ellipse or parabola. We review the nature of the bending, requirements and approaches to the mechanical design, and describe a technique developed at the ALS Optical Metrology Laboratory (OML) for optimal tuning of bendable mirrors before installation in the beamline [2]. The tuning technique adapts a method previously used to adjust bendable mirrors on synchrotron radiation beamlines [3]. However, in our case, optimal tuning of a bendable mirror is based on surface slope trace data obtained with a slope measuring instrument--in our case, the long trace profiler (LTP). We show that due to the near linearity of the bending problem, the minimal set of data, necessary for tuning of two benders, consists of only three slope traces measured before and after a single adjustment of each bending couple. We provide an algorithm that was used in dedicated software for finding optimal settings for the mirror benders. The algorithm is based on the method of regression analysis with experimentally found characteristic functions of the benders. The resulting approximation to the functional dependence of the desired slope shape provides nearly final settings for the benders. Moreover, the characteristic functions of the benders found in the course of tuning, can be used for retuning of the optics to a new desired shape without removing it from the beamline and re-measuring with the LTP. The result of practical use of the developed technique to precisely tune a KB mirror used at the ALS for micro-focusing is also presented. We also describe a simple ray trace using the profiler data which shows expected performance in the beamline and compare the simulation with experimental data. In summary, we also discuss the next steps in the systematic improvement of optical performance for the application of KB pairs in synchrotron beamlines at the ALS.

47 OTHER INSTRUMENTATION↗

Detection Performance of Upgraded "Polished Panel" Optical Receiver Concept on the Deep-Space Network's 34 Meter Research Antenna

The development and demonstration of a "polished panel" optical receiver concept on the 34 meter research antenna of the Deep Space Network (DSN) has been the subject of recent papers. This concept would enable simultaneous reception of optical and microwave signals by retaining the original shape of the main reflector for microwave reception, but with the aluminum panels polished to high reflectivity to enable focusing of optical signal energy as well. A test setup has been installed on the DSN's 34 meter research antenna at Deep Space Station 13 (DSS-13) of NASA's Goldstone Communications Complex in California, and preliminary experimental results have been obtained. This paper describes the results of our latest efforts to improve the point-spread function (PSF) generated by a custom polished panel, in an attempt to reduce the dimensions of the PSF, thus enabling more precise tracking and improved detection performance. The design of the new mechanical support structure and its operation are described, and the results quantified in terms of improvements in collected signal energy and optical communications performance, based on data obtained while tracking the planet Jupiter with the 34 meter research antenna at DSS-13.

photon-bucket receiver↗

Methane Quantification Performance of the Quantitative Optical Gas Imaging (QOGI) System Using Single-Blind Controlled Release Assessment

Quantitative optical gas imaging (QOGI) system can rapidly quantify leaks detected by optical gas imaging (OGI) cameras across the oil and gas supply chain. A comprehensive evaluation of the QOGI system’s quantification capability is needed for the successful adoption of the technology. This study conducted single-blind experiments to examine the quantification performance of the FLIR QL320 QOGI system under near-field conditions at a pseudo-realistic, outdoor, controlled testing facility that mimics upstream and midstream natural gas operations. The study completed 357 individual measurements across 26 controlled releases and 71 camera positions for release rates between 0.1 kg Ch 4 /h and 2.9 kg Ch 4 /h of compressed natural gas (which accounts for more than 90% of typical component-level leaks in several production facilities). The majority (75%) of measurements were within a quantification factor of 3 (quantification error of –67% to 200%) with individual errors between –90% and 831%, which reduced to –79% to +297% when the mean of estimates of the same controlled release from multiple camera positions was considered. Performance improved with increasing release rate, using clear sky as plume background, and at wind speeds ≤1 mph relative to other measurement conditions.

42 ENGINEERING↗

Parameter Uncertainties for a 10-Meter Ground-Based Optical Reception Station

Performance uncertainties for a 10-m optical reception station may arise from the nature of the communications channel or from a specific technology choice. Both types of uncertainties are described in this article to develop an understanding of the limitations imposed by them and to provide a rational basis for making technical decisions. The performance at night will be considerably higher than for daytime reception.

Shaik, K.↗