Search NASA⌕ Search

SEARCH · Search NASA

Results for “parameter sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Mesospheric Water Vapor Retrieved from SABER/TIMED Measurements

The SABER instrument on board the TIMED satellite is a limb scanning infrared radiometer designed to measure temperature and minor constituent vertical profiles and energetics parameters in the mesosphere and lower thermosphere (MLT) The H2O concentrations are retrieved from 6.3 micron band radiances. The interpretation of this radiance requires developing a non-LTE H2O model that includes energy exchange processes with the system of O3 and O2 vibrational levels populated at the daytime through a number of photoabsorption and photodissociation processes. We developed a research model base on an extended H2O non-LTE model of Manuilova coupled with the novel model of the electronic kinetics of the O2 and O3 photolysis products suggested by Yankosvky and Manuilova. The performed study of this model helped u to develop and test an optimized operational model for interpretation of SABER 6.3 micron band radiances. The sensitivity of retrievals to the parameters of the model is discussed. The H2O retrievals are compared to other measurements for different seasons and locations.

Feofilov, Arte, G.↗

An enhancement to the NA4 gear vibration diagnostic parameter

A new vibration diagnostic parameter for health monitoring of gears, NA4*, is proposed and tested. A recently developed gear vibration diagnostic parameter NA4 outperformed other fault detection methods at indicating the start and initial progression of damage. However, in some cases, as the damage progressed, the sensitivity of the NA4 and FM4 parameters tended to decrease and no longer indicated damage. A new parameter, NA4* was developed by enhancing NA4 to improve the trending of the parameter. This allows for the indication of damage both at initiation and also as the damage progresses. The NA4* parameter was verified and compared to the NA4 and FM4 parameters using experimental data from single mesh spur and spiral bevel gear fatigue rigs. The primary failure mode for the test cases was naturally occurring tooth surface pitting. The NA4* parameter is shown to be a more robust indicator of damage.

Decker, Harry J.↗

Variation of Local Liquid-Water Concentration About and Ellipsoid of Fineness Ratio 5 Moving in a Droplet Field

Trajectories of water droplets about an ellipsoid of revolution with a fineness ratio of 5 (which often approximates the shape of an aircraft fuselage or missile) were computed with the aid of a differential analyzer. Analyses of these trajectories indicate that the local concentration of liquid water at various points about an ellipsoid in flight through a droplet field varies considerably and under some conditions may be several times the free-stream concentration. Curves of the local concentration factor as a function of spatial position were obtained and are presented in terms of dimensionless parameters Re(sub 0) (free-stream Reynolds number) and K (inertia), which contain flight and atmospheric conditions. These curves show that the local concentration factor at any point is very sensitive to change in the dimensionless parameters Re(sub 0) and K. These data indicate that the expected local concentration factors should be considered when choosing the location of, or when determining antiicing heat requirements for, water- or ice-sensitive devices that protrude into the stream from an aircraft fuselage or missile. Similarly, the concentration factor should be considered when choosing the location on an aircraft of instruments that measure liquid-water content or droplet-size distribution in the atmosphere.

Dorsch, Robert G.↗

Development of a laboratory prototype water quality monitoring system suitable for use in zero gravity

The development of a laboratory prototype water quality monitoring system for use in the evaluation of candidate water recovery systems and for study of techniques for measuring potability parameters is reported. Sensing techniques for monitoring of the most desirable parameters are reviewed in terms of their sensitivities and complexities, and their recommendations for sensing techniques are presented. Rationale for selection of those parameters to be monitored (pH, specific conductivity, Cr(+6), I2, total carbon, and bacteria) in a next generation water monitor is presented along with an estimate of flight system specifications. A master water monitor development schedule is included.

Misselhorn, J. E.↗

Model-based parameter estimation using cardiovascular response to orthostatic stress

This paper presents a cardiovascular model that is capable of simulating the short-term (< or approximately equal to 3 min) transient hemodynamic response to gravitational stress and a gradient-based optimization method that allows for the automated estimation of model parameters from simulated or experimental data. We perform a sensitivity analysis of the transient heart rate response to determine which parameters of the model impact the heart rate dynamics significantly. We subsequently include only those parameters in the estimation routine that impact the transient heart rate dynamics substantially. We apply the estimation algorithm to both simulated and real data and showed that restriction to the 20 most important parameters does not impair our ability to match the data.

Non-NASA Center↗

Preliminary Error Budget for the Reflected Solar Instrument for the Climate Absolute Radiance and Refractivity Observatory

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) plans to observe climate change trends over decadal time scales to determine the accuracy of climate projections. The project relies on spaceborne earth observations of SI-traceable variables sensitive to key decadal change parameters. The mission includes a reflected solar instrument retrieving at-sensor reflectance over the 320 to 2300 nm spectral range with 500-m spatial resolution and 100-km swath. Reflectance is obtained from the ratio of measurements of the earth s surface to those while viewing the sun relying on a calibration approach that retrieves reflectance with uncertainties less than 0.3%. The calibration is predicated on heritage hardware, reduction of sensor complexity, adherence to detector-based calibration standards, and an ability to simulate in the laboratory on-orbit sources in both size and brightness to provide the basis of a transfer to orbit of the laboratory calibration including a link to absolute solar irradiance measurements. The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission addresses the need to observe high-accuracy, long-term climate change trends and to use decadal change observations as the most critical method to determine the accuracy of climate change projections such as those in the IPCC Report. A rigorously known accuracy of both decadal change observations as well as climate projections is critical in order to enable sound policy decisions. The CLARREO Project will implement a spaceborne earth observation mission designed to provide rigorous SI traceable observations (i.e., radiance, reflectance, and refractivity) that are sensitive to a wide range of key decadal change variables, including: 1) Surface temperature and atmospheric temperature profile 2) Atmospheric water vapor profile 3) Far infrared water vapor greenhouse 4) Aerosol properties and anthropogenic aerosol direct radiative forcing 5) Total and spectral solar irradiance 6) Broadband reflected and emitted radiative fluxes 7) Cloud properties 8) Surface albedo There are two methods the CLARREO mission will rely on to achieve these critical decadal change benchmarks: direct and reference inter-calibration. A quantitative analysis of the strengths and weaknesses of the two methods has led to the recommended CLARREO mission approach. The project consists of two satellites launched into 90-degree, precessing orbits separated by 90 degrees. The instrument suite receiver on each spacecraft includes one emitted infrared spectrometer, two reflected solar spectrometers: dividing the spectrum from ultraviolet through near infrared, and one global navigation receiver for radio occultation. The measurements will be acquired for a period of three years minimum, with a five-year lifetime goal, enabling follow-on missions to extend the climate record over the decades needed to understand climate change. The current work concentrates on the reflected solar instrument giving an overview of its design and calibration approach. The calibration description includes the approach to achieving an SI-traceable system on orbit. The calibration overview is followed by a preliminary error budget based on techniques currently in place at the National Institute of Standards and Technology (NIST).

Thome, Kurtis↗

Fine Sun Sensor Field of View Calibration

The fine Sun sensor (FSS) used on many spacecraft consists of two independent single-axis sensors, nominally mounted perpendicularly, that detect Sun angle across a typical field of view of +/- 32 degrees. The nonlinear function that maps the measured counts into an observed angle is called the transfer function. The FSS transfer function provided by the manufacturer consists of nine parameters for each of the two sensitive axes. An improved transfer function has been previously reported that achieves a significant accuracy improvement across the entire field of view. This new function expands the parameter set to 12 coefficients per axis and includes cross terms combining counts from both axes. To make best use of the FSS for spacecraft attitude determination, it must be calibrated after launch. We are interested in simplifying the postlaunch calibration procedure for estimating improvements to the 24 parameters in the transfer function. This paper discusses how to recombine the terms of the transfer function to reduce their redundancy without decreasing its accuracy and then presents an attitude dependent procedure for estimating the parameters. The end result is a calibration algorithm that is easier to use and does not sacrifice accuracy. Results of calibration using on-orbit data are presented.

Sedlak, Joseph E.↗

A stochastic differential equation model of diurnal cortisol patterns

Circadian modulation of episodic bursts is recognized as the normal physiological pattern of diurnal variation in plasma cortisol levels. The primary physiological factors underlying these diurnal patterns are the ultradian timing of secretory events, circadian modulation of the amplitude of secretory events, infusion of the hormone from the adrenal gland into the plasma, and clearance of the hormone from the plasma by the liver. Each measured plasma cortisol level has an error arising from the cortisol immunoassay. We demonstrate that all of these three physiological principles can be succinctly summarized in a single stochastic differential equation plus measurement error model and show that physiologically consistent ranges of the model parameters can be determined from published reports. We summarize the model parameters in terms of the multivariate Gaussian probability density and establish the plausibility of the model with a series of simulation studies. Our framework makes possible a sensitivity analysis in which all model parameters are allowed to vary simultaneously. The model offers an approach for simultaneously representing cortisol's ultradian, circadian, and kinetic properties. Our modeling paradigm provides a framework for simulation studies and data analysis that should be readily adaptable to the analysis of other endocrine hormone systems.

NASA Discipline Space Human Factors↗

Characterization of Silicon Carbide Pressure Sensors at 800 °C

We have performed the initial characterization of single crystal 4H silicon carbide (4H-SiC) pressure sensors to determine the operational reliability over time at 800 °C. Important parameters such as the zero pressure offset, bridge resistance, and pressure sensitivity as they are affected by temperature were extracted. These parameters showed relative stability within the prescribed operational envelop of the sensor at 800 °C. Of significance is the increase in pressure sensitivity with increasing temperature beyond 400 °C, to the extent that the sensitivity at 800 °C was higher than the room temperature value. The implication of this result is that the sensor can be inserted further into the high temperature environment, thereby capturing the wider bandwidth of the pressure transients than currently possible.

Okojie, Robert S.↗

Towards an intuitive application of WEC control co-design

A simple co-design example in a reduced parameter space is presented for an oscillating flap device. Initially, the WEC geometry and mass properties are considered along with drivetrain gear ratio, inertia, motor constant and stiffness under both PI and optimal control. This parameter space is reduced to those to which performance is most sensitive for a fixed geometry. The gear ratio, drivetrain stiffness, and flap mass are found to be the most impactful design criteria as they can create orders of magnitude variations in power performance. The performance of the optimized system is compared with several sub-optimal variants in terms of electrical and mechanical power capture, transmission coefficients, and transducer power gain. Notably, though substantial power capture improvements are demonstrated when an optimal controller is employed, this power capture remains sensitive to appropriate selections of drivetrain and flap design parameters, implying that control co-design procedures remain necessary for high-performing WECs. Furthermore, a number of practical caveats and extensions to the presented co-design methodology are suggested, including the characterization of system static friction, especially in the presence of high gear ratios.

Control co-design↗

CO fundamental bands in late-type stars. II - Spectrum simulations for F-K stars

The procedure of Ayres and Wiedemann (1989) was applied to a range of stellar-atmosphere models to study the CO Delta-v = 1 spectrum and to establish its use as a remote sensor of thermal conditions in late-type stars. Spectra were computed to examine the sensitivity of the CO Delta-v = 1 to fundamental stellar parameters and to assess the errors introduced into the spectrum intepretation by uncertain input parameters and non-LTE effects. Results of the sensitivity study demonstrate that CO fundamental spectra are useful probes for the temperature structure of the outer layers of cool stellar atmospheres, but that their value is limited by the uncertainties introduced by non-LTE effects. However, in stars with surface gravities of log g of about 1.5 and greater, the values of these uncertainties are reasonably small.

Wiedemann, Guenter↗

Provably conservative approximations to complex reliability models

Complex models can be the bases for derivation of provably conservative and optimistic reliability models that incorporate a reduced state space and fewer transitions; they accordingly possess solutions that are more cost-effective than those of the original complex models. Design space can thereby be extensively explored without incurring the expense of multiple complex model solutions. A conservative-optimistic pair of derived models produces a band that includes the solution to the complex model. Sensitivity analysis can be performed on this pair of models to determine those parameters of the original model that are most sensitive to change and therefore require further expense in obtaining tighter specifications.

Smotherman, M.↗

Modeling the X-Ray Process, and X-Ray Flaw Size Parameter for POD Studies

Nondestructive evaluation (NDE) method reliability can be determined by a statistical flaw detection study called probability of detection (POD) study. In many instances the NDE flaw detectability is given as a flaw size such as crack length. The flaw is either a crack or behaving like a crack in terms of affecting the structural integrity of the material. An alternate approach is to use a more complex flaw size parameter. The X-ray flaw size parameter, given here, takes into account many setup and geometric factors. The flaw size parameter relates to X-ray image contrast and is intended to have a monotonic correlation with the POD. Some factors such as set-up parameters including X-ray energy, exposure, detector sensitivity, and material type that are not accounted for in the flaw size parameter may be accounted for in the technique calibration and controlled to meet certain quality requirements. The proposed flaw size parameter and the computer application described here give an alternate approach to conduct the POD studies. Results of the POD study can be applied to reliably detect small flaws through better assessment of effect of interaction between various geometric parameters on the flaw detectability. Moreover, a contrast simulation algorithm for a simple part-source-detector geometry using calibration data is also provided for the POD estimation.

Khoshti, Ajay↗

Modeling the X-ray Process, and X-ray Flaw Size Parameter for POD Studies

Nondestructive evaluation (NDE) method reliability can be determined by a statistical flaw detection study called probability of detection (POD) study. In many instances, the NDE flaw detectability is given as a flaw size such as crack length. The flaw is either a crack or behaving like a crack in terms of affecting the structural integrity of the material. An alternate approach is to use a more complex flaw size parameter. The X-ray flaw size parameter, given here, takes into account many setup and geometric factors. The flaw size parameter relates to X-ray image contrast and is intended to have a monotonic correlation with the POD. Some factors such as set-up parameters, including X-ray energy, exposure, detector sensitivity, and material type that are not accounted for in the flaw size parameter may be accounted for in the technique calibration and controlled to meet certain quality requirements. The proposed flaw size parameter and the computer application described here give an alternate approach to conduct the POD studies. Results of the POD study can be applied to reliably detect small flaws through better assessment of effect of interaction between various geometric parameters on the flaw detectability. Moreover, a contrast simulation algorithm for a simple part-source-detector geometry using calibration data is also provided for the POD estimation.

Koshti, Ajay M.↗

The compositional structure and the effects of exothermicity in a nonpremixed planar jet flame

Results are presented of direct numerical simulation (DNS) of a randomly perturbed compressible, spatially developing two-dimensional planar jet under the influence of a finite rate chemical reaction of the type F + O yields product. The objectives of the simulations are to assess the compositional structure of the flame and to determine the influence of reaction exothermicity by means of statistical sampling of the DNS generated data. It is shown that even with this idealized kinetics model the simulated results exhibit features in accord with experimental data. These results indicate that the Damkohler number is an important parameter in determining the statistical composition of the reacting field and that the results are not very sensitive to the mechanism by which this parameter is varied. It is demonstrated that as the intensity of mixing is increased and the effect of finite rate chemistry is more pronounced, the magnitudes of the ensemble mean and variance of the product mass fraction decrease and those of the reactants' mass fraction increase. Also, at higher mixing rates the joint probability density functions of the reactants' mass fractions shift towards higher values within the composition domain, indicating a lower reactedness.

Steinberger, C. J.↗

MXER Simulation Study (Appendix B)

The task of prediction of the motion of a momentum exchange system with a 9-digit accuracy is extremely challenging, and it is relentlessly testing our ability to gain fundamental insights into the nature of the tether dynamics in this system. It has been show that the modal decomposition approach developed in the first part of this study is a very powerful and precise tool for the simulation of the dynamics of momentum exchange tethers. However, to get a prediction with required accuracy using this tool, one must have precise inputs, including the initial state, system parameters, and the environmental models. In simulations, the tether tip positioning has been observed to be quite sensitive to even small variations of the parameters involved in the calculations. It is therefore imperative that precise estimation and control algorithms be developed to compensate for the inevitable uncertainties and support high precision rendezvous.

Levin, E. M.↗

Model updating based on sensitivities of system matrices

A new approach, which allows the physical parameters to be adjusted and preserves the structural connectivity condition, is developed in this paper. This approach is based on the sensitivities of the mass and stiffness matrices with respect to physical parameters in an attempt to use test data to correct the analytical model. The analytical mass and stiffness matrices can be corrected simultaneously. The modal data of the updated model dramatically converges to that of the test model. A numerical example is presented to illustrate the feasibility of this approach. Comparisons with the other methods are also given.

Huang, Hsin-Hsen↗