Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Improving Fission Products at CARIBU: Near Field Detection (Q1/FY24 Quarterly Progress Report)

The article on “Direct Mass Measurements to Inform the Behavior for 128mSb in Nucleosynthesis Environments” by Daniel Hoff et al., recently published in Physical Review Letters. The results of the work are a combination of an extraordinary work on precision mass measurements performed with the Canadian Penning Trap at ANL (the most precise mass measurement of the ground state and the isomeric state in 128Sb performed to date), and an extensive nucleosynthesis theory calculation that include isomers performed by the theorists at LANL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determining g A / g V with High-Resolution Spectral Measurements Using a LiInSe 2 Bolometer

Neutrinoless double beta decay (0νββ) processes sample a wide range of intermediate forbidden nuclear transitions, which may be impacted by quenching of the axial vector coupling constant (g A /g V ), the uncertainty of which plays a pivotal role in determining the sensitivity reach of 0νββ experiments. Here we present measurements performed on a high-resolution LiInSe 2 bolometer in a “source = detector” configuration to measure the spectral shape of the fourfold forbidden β decay of 115 In . The value of g A /g V is determined by comparing the spectral shape of theoretical predictions to the experimental β spectrum taking into account various simulated background components as well as a variety of detector effects. We find evidence of quenching of g A /g V at >5 σ with a model-dependent quenching factor of 0.655 ± 0.002 as compared to the free-nucleon value for the interacting shell model. We also measured the 115 In half-life to be [5.18 ± 0.06(stat) $^{+0.005}_{- 0.015}$(sys)] x 10 14 yr within the interacting shell model framework. This Letter demonstrates the power of the bolometeric technique to perform precision nuclear physics single-β decay measurements, which along with improved nuclear modeling can help reduce the uncertainties in the calculation of several decay nuclear matrix elements including those used in 0νββ sensitivity calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Institute for Sustained Performance, Energy, and Resilience (SuPER)

The University of Tennessee (UTK) and University of Texas at El Paso (UTEP) partnership supported the three main thrusts of the SUPER project---performance, energy, and resilience. The UTK-UTEP effort thus helped advance the main goal of SUPER, which was to ensure that DOE's computational scientists can successfully exploit the emerging generation of high performance computing (HPC) systems. This goal is being met by providing application scientists with strategies and tools to productively maximize performance, conserve energy, and attain resilience. The primary vehicle through which UTK provided performance measurement support to SUPER and the larger HPC community is the Performance Application Programming Interface (PAPI). PAPI is an ongoing project that provides a consistent interface and methodology for collecting hardware performance information from various hardware and software components, including most major CPUs, GPUs and accelerators, interconnects, I/O systems, and power interfaces, as well as virtual cloud environments. The PAPI software is widely used for performance modeling of scientific and engineering applications---for example, the HOMME (High Order Methods Modeling Environment) climate code, and the GAMESS and NWChem computational chemistry codes---on DOE supercomputers. PAPI is widely deployed as middleware for use by higher-level profiling, tracing, and sampling tools (e.g., CrayPat, HPCToolkit, Scalasca, Score-P, TAU, Vampir, PerfExpert), making it the de facto standard for hardware counter analysis. PAPI has established itself as fundamental software infrastructure in every application domain (spanning academia, government, and industry), where improving performance can be mission critical. Ultimately, as more application scientists migrate their applications to HPC platforms, they will benefit from the extended capabilities this grant brought to PAPI to analyze and optimize performance in these environments, whether they use PAPI directly, or via third-party performance tools. Capabilities added to PAPI through this grant include support for new architectures such as the lastest GPU and Xeon Phi accelerators, and advanced power measurement and management features. Another important topic for the UTK team was providing support for a rich ecosystem of different fault management strategies in the context of parallel computing. Our long term efforts have been oriented toward proposing flexible strategies and providing building boxes that application developers can use to build the most efficient fault management technique for their application. These efforts span across the entire software spectrum, from theoretical models of existing strategies to easily assess their performance, to algorithmic modifications to take advantage of specific mathematical properties for data redundancy and to extensions to widely used programming paradigms to empower the application developers to deal with all types of faults. We have also continued our tight collaborations with users to help them adopt these technologies to ensure their application always deliver meaningful scientific data. Large supercomputer systems are becoming more and more power and energy constrained, and future systems and applications running on them will need to be optimized to run under power caps and/or minimize energy consumption. The UTEP team contributed to the SUPER energy thrust by developing power modeling methodologies and investigating power management strategies. Scalability modeling results showed that some applications can scale better with respect to an increasing power budget than with respect to only the number of processors. Power management, in particular shifting power to processors on the critical path of an application execution, can reduce perturbation due to system noise and other sources of runtime variability, which are growing problems on large-scale power-constrained computer systems.

42 ENGINEERING↗

A dosimetric evaluation of the Eclipse AAA algorithm and Millennium 120 MLC for cranial intensity-modulated radiosurgery

The aim of this study is to assess the accuracy of a convolution-based algorithm (anisotropic analytical algorithm [AAA]) implemented in the Eclipse planning system for intensity-modulated radiosurgery (IMRS) planning of small cranial targets by using a 5-mm leaf-width multileaf collimator (MLC). Overall, 24 patient-based IMRS plans for cranial lesions of variable size (0.3 to 15.1 cc) were planned (Eclipse, AAA, version 10.0.28) using fixed field-based IMRS produced by a Varian linear accelerator equipped with a 120 MLC (5-mm width on central leaves). Plan accuracy was evaluated according to phantom-based measurements performed with radiochromic film (EBT2, ISP, Wayne, NJ). Film 2D dose distributions were performed with the FilmQA Pro software (version 2011, Ashland, OH) by using the triple-channel dosimetry method. Comparison between computed and measured 2D dose distributions was performed using the gamma method (3%/1 mm). Performance of the MLC was checked by inspection of the DynaLog files created by the linear accelerator during the delivery of each dynamic field. The absolute difference between the calculated and measured isocenter doses for all the IMRS plans was 2.5% ± 2.1%. The gamma evaluation method resulted in high average passing rates of 98.9% ± 1.4% (red channel) and 98.9% ± 1.5% (blue and green channels). DynaLog file analysis revealed a maximum root mean square error of 0.46 mm. According to our results, we conclude that the Eclipse/AAA algorithm provides accurate cranial IMRS dose distributions that may be accurately delivered by a Varian linac equipped with a Millennium 120 MLC.

61 RADIATION PROTECTION AND DOSIMETRY↗

Toward real-time performance benchmarks for Ada

The issue of real-time performance measurements for the Ada programming language through the use of benchmarks is addressed. First, the Ada notion of time is examined and a set of basic measurement techniques are developed. Then a set of Ada language features believed to be important for real-time performance are presented and specific measurement methods discussed. In addition, other important time related features which are not explicitly part of the language but are part of the run-time related features which are not explicitly part of the language but are part of the run-time system are also identified and measurement techniques developed. The measurement techniques are applied to the language and run-time system features and the results are presented.

Clapp, Russell M.↗

Early performance of the 12-GHz, 200-watt transmitter experiment package in the communications technology satellite

Measured performance characteristics of the transmitter experiment package (TEP) aboard the Communications Technology Satellite for the first 90 operating days in orbit are presented. The TEP consists of a nominal 200-watt output stage tube (OST), a supporting power processing system (PPS), and a variable-conductance heat pipe system (VCHPS). The OST, a traveling-wave tube augmented with a 10-stage depressed collector, has an overall saturated average efficiency of 51.5 percent and an average saturated radiofrequency (RF) output power at center-band frequency of 240 watts. The PPS operated with a measured efficiency of 86.5 percent to 88.5 percent. The VCHPS, using three pipes to conduct heat from the PPS and the body of the OST to a 52-centimeter by 124-centimeter (20.5-in. by 48.75-in.) radiator fin, maintained by the PPS baseplate temperature below 50 C for all operating conditions. The TEP performance characteristics presented include frequency response, RF output power, efficiency, and distortions. Communications characteristics were evaluated by using both video and audio modulated signals.

Source record↗

Dissociation of performance and subjective measures of workload

A theory is presented to identify sources that produce dissociations between performance and subjective measures of workload. The theory states that performance is determined by (1) amount of resources invested, (2) resource efficiency, and (3) degree of competition for common resources in a multidimensional space described in the multiple-resources model. Subjective perception of workload, multidimensional in nature, increases with greater amounts of resource investment and with greater demands on working memory. Performance and subjective workload measures dissociate when greater resources are invested to improve performance of a resource-limited task; when demands on working memory are increased by time-sharing between concurrent tasks or between display elements; and when performance is sensitive to resource competition and subjective measures are more sensitive to total investment. These dissociation findings and their implications are discussed and directions for future research are suggested.

Yeh, Yei-Yu↗

Measurements of matrix cracking and delamination caused by impact on composite plates

Tests were performed measuring the locations and extents of delaminations and matrix crackings in 3-in. by 3-in. Fiberite T300/934 graphite/epoxy plates impacted by 1/2-in. diameter aluminum spheres. Plates with six ply orientations were tested. The impactor speeds ranged from 700 to 1300 in/sec. The plates were inspected by C-scan both before and after impact. The plates were also dissected after impact and examined visually for damage. In addition, the longitudinal and transverse tensile, compressive, and shear properties of the material were measured.

Wu, Hsi-Yung T.↗

Force Measurements of Single and Double Barrier DBD Plasma Actuators in Quiescent Air

We have performed measurements of the force induced by both single (one electrode insulated) and double (both electrodes insulated) dielectric barrier discharge plasma actuators in quiescent air. We have shown that, for single barrier actuators, as the electrode diameter decreased below those values previously studied the induced Force increases exponentially rather than linearly. This behavior has been experimentally verified using two different measurement techniques: stagnation probe measurements of the induced flow velocity and direct measurement of the force using an electronic balance. In addition, we have shown the the induced force is independent of the material used for the exposed electrode. The same techniques have shown that the induced force of a double barrier actuator increases with decreasing narrow electrode diameter.

Hoskinson, Alan R.↗

4D Emittance Measurements Using Multiple Wire and Waist Scan Methods in the ATF Extraction Line

Emittance measurements performed in the diagnostic section of the Accelerator Test Facility (ATF) extraction line since 1998 led to vertical emittances three times larger than the expected ones, with a strong dependence on intensity. An experimental program is pursued to investigate potential sources of emittance growth and find possible remedies. This requires efficient and reliable emittance measurement techniques. In the past, several phase-space reconstruction methods developed at SLAC and KEK have been used to estimate the vertical emittance, based on multiple location beam size measurements and dedicated quadrupole scans. These methods have been shown to be very sensitive to measurement errors and other fluctuations in the beam conditions. In this context new emittance measurements have been performed revisiting these methods and newly developed ones with a systematic approach to compare and characterise their performance in the ATF extraction line.

43 PARTICLE ACCELERATORS↗

So ware-Defined Network Solutions for Science Scenarios: Performance Testing Framework and Measurements

High-performance scientific work flows utilize supercomputers, scientific instruments, and large storage systems. Their executions require fast setup of a small number of dedicated network connections across the geographically distributed facility sites. We present Software-Defined Network (SDN) solutions consisting of site daemons that use dpctl, Floodlight, ONOS, or OpenDaylight controllers to set up these connections. The development of these SDN solutions could be quite disruptive to the infrastructure, while requiring a close coordination among multiple sites; in addition, the large number of possible controller and device combinations to investigate could make the infrastructure unavailable to regular users for extended periods of time. In response, we develop a Virtual Science Network Environment (VSNE) using virtual machines, Mininet, and custom scripts that support the development, testing, and evaluation of SDN solutions, without the constraints and expenses of multi-site physical infrastructures; furthermore, the chosen solutions can be directly transferred to production deployments. By complementing VSNE with a physical testbed, we conduct targeted performance tests of various SDN solutions to help choose the best candidates. In addition, we propose a switching response method to assess the setup times and throughput performances of different SDN solutions, and present experimental results that show their advantages and limitations.

Settlemyer, Bradley↗

Low Count and Background Radionuclides Analysis - 20488

The US Department of Energy (DOE) is often faced with the need to evaluate radionuclides at low concentrations. When site sample data are likely to be close to threshold activity concentrations of interest, then the means by which the radiochemical analysis is performed and reported is critical. This situation can occur when differentiating from zero (presence/absence) for radionuclides that do not occur naturally, close comparison with environmental background for naturally occurring radionuclides, close comparison with a risk- or dose-based threshold concentrations of interest, or even comparisons across studies. There are several analytical issues that are of concern, but the two that appear to cause incorrect decisions to be made most often involve establishing detection limits and subtracting ambient background conditions in the laboratory. These issues are not critical when radionuclide activity concentrations are large relative to thresholds of concern, but they seem to be poorly understood when it matters. When the comparisons are important and are likely to be close to a threshold of interest, then the general contract with the analytical laboratories needs to be changed so that the right or appropriate data are obtained. The concern is that important decisions are made incorrectly more often as greater scrutiny is placed on DoE's radionuclide cleanup or monitoring decisions by the public and other stakeholders. Examples are presented of problems that have been observed for different projects, both within and outside the realm of DOE and NRC remediation and radioactive waste disposal problems, and solutions are offered that should lead to better data from which important decisions need to be made. The first example is from Los Alamos National Laboratory (LANL) and involves radionuclide concentrations in soil and rock beneath LANL's Material Disposal Area (MDA) G. An initial review of the data led to a conclusion that americium and plutonium are a long way present beneath MDA G. A more thorough review of the data that accounted properly for ambient background and the detection limits that had been established led to the opposite conclusion. Another example is from the Nevada National Security Site where tritium results from one of the wells were unexpectedly high. Proper understanding and analysis of ambient background led to the conclusion that the increased concentrations were not so obvious, and that a different contract with the analytical laboratory was needed to provide more appropriate data to support a better determination. Other examples are used from regulatory review of projects in Nevada, where background levels and secular equilibrium for naturally occurring radionuclides are not established correctly because of analytical issues. The same basic issues have also been found to create difficulties analyzing historical data from the West Valley Demonstration Project. There is evidence in the data that the apparent lack of secular equilibrium where it is expected to exist is related to ambient background subtraction or other analytical issues. A final example is presented for analysis of Tc-99 in samples of depleted uranium. In this case, two different studies that were performed only three months apart provide quite different results. The US Environmental Protection Agency (EPA) established the data quality objectives (DQO) process in the mid-1980's to establish decision performance criteria for data collection. EPA guidance (EPA G-4, for example) clearly distinguishes between DQOs and measurement performance objectives (MQOs) that should be addressed for laboratory analysis of samples. The language of DQOs and MQOs has become confused over time it seems, and the subsequent effects seem to include a lack of attention to decision performance and a routine approach to measurement quality. In order to better address radionuclide sample analysis when the concentrations are close to thresholds of concern, which might be zero for some radionuclides, background for others, and risk-based thresholds for yet others, it is important that routine laboratory analysis methods are adjusted, and that the project team and the laboratory work closely together to ensure that the data meets the MQO requirements of laboratory analysis and reporting of results, and that the MQOs effectively support project-specific DQOs. This basic approach will be applied in Los Alamos in the coming year to the collection of moisture data from underneath MDA T that will be analyzed for americium and neptunium isotopes. Proper understanding of the radiochemistry methods and reporting, and of appropriate statistical methods is critical to the success of such projects, ensuring that the right decisions are made. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Implementation of a System of Gamma Imagers for Measuring Plutonium Holdup

The Surplus Plutonium Disposition (SPD) project is an effort to dilute and dispose of many tonsof weapons grade plutonium. This work will take place in a shielded glovebox to protect workers fromradiological dose. Accurate measurements of the holdup, or material left behind, in the gloveboxes is im-portant for Nuclear Material Control and Accountancy, worker dose minimization, criticality safety, andprocess monitoring. Shielding around the gloveboxes presents an obstacle for the traditional GeneralizedGamma Holdup (GGH) method. The uncertainties associated with that method, at around 28%, arealso detrimental since the amount of holdup must be kept below an established limit with a high level ofconfidence.Passive gamma-ray imaging provides a more complete depiction of the distribution of radioactivematerials. Recent refinement of the method has demonstrated that quantitative information can beextracted from the images with a well-characterized system. A permanently installed system of gamma-ray imagers is currently being developed to measure plutonium holdup in the SPD gloveboxes. Thispaper will report on progress with the development of this system.This application requires that the features of current commercially available instruments from H3Dand PHDS, optimized for measurement performance in a mobile application, be translated into theconstraints of the operational environment with fixed installations. The interaction between facilityconstraints and measurement capabilities will be addressed.A series of measurements with plutonium sources in a mocked-up glovebox geometry with imagersmounted above the ceiling of the glovebox have been taken. Imager performance with respect to angularresolution, minimum measurement time for quantification, and signal-to-noise ratio with a multitudeof sources will be evaluated for those measurements. A series of prototypes of user interfaces will bepresented for display of the data to its various consumers for the purposes of Nuclear Material Controland Accountancy, worker dose minimization, criticality safety, and process monitoring.

Schmitt, Kyle↗

Measurement and QCD analysis of double-differential inclusive jet cross sections in pp collisions at $ \sqrt{s}=8 $ TeV and cross section ratios to 2.76 and 7 TeV

A measurement of the double-differential inclusive jet cross section as a function of the jet transverse momentum p$_{T}$ and the absolute jet rapidity |y| is presented. Data from LHC proton-proton collisions at $ \sqrt{s}=8 $ TeV, corresponding to an integrated luminosity of 19.7 fb$^{−1}$, have been collected with the CMS detector. Jets are reconstructed using the anti-k$_{T}$ clustering algorithm with a size parameter of 0.7 in a phase space region covering jet p$_{T}$ from 74 GeV up to 2.5 TeV and jet absolute rapidity up to |y| = 3.0. The low-p$_{T}$ jet range between 21 and 74 GeV is also studied up to |y| = 4.7, using a dedicated data sample corresponding to an integrated luminosity of 5.6 pb$^{−1}$. The measured jet cross section is corrected for detector effects and compared with the predictions from perturbative QCD at next-to-leading order (NLO) using various sets of parton distribution functions (PDF). Cross section ratios to the corresponding measurements performed at 2.76 and 7 TeV are presented. From the measured double-differential jet cross section, the value of the strong coupling constant evaluated at the Z mass is α$_{S}$(M$_{Z}$) = 0.1164$_{− 0.0043}^{+ 0.0060}$ , where the errors include the PDF, scale, nonperturbative effects and experimental uncertainties, using the CT10 NLO PDFs. Improved constraints on PDFs based on the inclusive jet cross section measurement are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cryogenic-Refined MOSFET Modeling for Oscillator, Frequency Divider, and Amplifier Designs Below 4 K

Capturing device characteristic changes at cryogenic temperatures is crucial for cryo-CMOS circuit designs. In this work, we present an isothermal cryogenic-refined modeling approach for CMOS transistors that is simple, low overhead, and easy to implement while offering the required accuracy for predicting circuit performance at the designated temperatures. Guided by die-level measurement data and circuit design principles, the model introduces corrections to only five critical parameters: threshold voltage, carrier mobility, elevated low-frequency flicker noise, dominant high-frequency shot noise, and subthreshold swing (SS). These refinements are implemented around the foundry-provided SPICE model, which is typically validated only down to about 200 K. With these adjustments, the proposed cryogenic-refined model achieves less than 5% error in both large-signal metrics (I–V characteristics) and small-signal parameters (e.g., transconductance) when compared with device measurements at deep-cryogenic temperatures. The methodology is validated in two advanced technologies: TSMC 40-nm CMOS and GlobalFoundries (GF) 45-nm RF-SOI. We further demonstrate its applicability in three representative RF circuits: a 30-GHz LC oscillator, a high-speed current-mode-logic (CML) frequency divider (FD), and a subthreshold Gb/s amplifier, all showing close agreement between simulated predictions and measurements performed at 4 and 2.5 K. Finally, we believe that the proposed approach is implementation-friendly and can significantly accelerate the development of cryo-CMOS integrated circuits.

circuit modeling↗

SU-G-JeP1-13: Innovative Tracking Detector for Dose Monitoring in Hadron Therapy: Realization and Monte Carlo Simulations

Purpose: Development of strategies to monitor range uncertainties is necessary to improve treatment planning in Charged Particle Therapy (CPT) and fully exploit the advantages of ion beams. Our group developed (within the framework of the INSIDE project funded by the Italian research ministry) and is currently building a compact detector Dose Profiler (DP) able to backtrack charged secondary particles produced in the patient during the irradiation. Furthermore we are studying monitoring strategy exploiting charged secondary emission profiles to control the range of the ion beam. Methods: This contribution reports on the DP detector design and construction status. The detector consists of a charged secondary tracker composed of scintillating fiber layers and a LYSO calorimeter for particles energy measurement.The detector layout has been optimized using the FLUKA Monte Carlo (MC) simulation software. The simulation of a 220 MeV Carbon beam impinging on a PMMA target has been performed to study the detector response, exploiting previous secondary radiation measurements performed by our group. The emission profile of charged secondary particles was reconstructed backtracking the particles to their generation point to benchmark the DP performances. Results: The DP construction status, including the technological details will be presented. The feasibility of range monitoring with DP will be demonstrated by means of MC studies. The correlation of the charged secondary particles emission shape with the position of the Bragg peak (BP) will be shown, as well as the spatial resolution achievable on the BP position estimation (less than 3 mm) in the clinical like conditions. Conclusion: The simulation studies supported the feasibility of an accurate range monitoring technique exploiting the use of charged secondary fragments emitted during the particle therapy treatment. The DP experimental tests are foreseen in 2016, at CNAO particle therapy center in Pavia.

60 APPLIED LIFE SCIENCES↗

Implementing Arbitrary/Common Concurrent Writes of CRCW PRAM

The Parallel Random Access Machines (PRAM) abstraction is the simplest and most elegant algorithmic model for the design and analysis of parallel algorithms. It consists of different models categorized based on the underlying memory access mode used, the most powerful of which is the Concurrent Read Concurrent Write (CRCW) model. A PRAM algorithm describes a series of rounds, each of which consists of a collection of operations that can be executed concurrently within the same time step. However, the lack of support for concurrent memory accesses and the prevalence of asynchronous programming models led to the belief that implementing CRCW PRAM algorithms is unattainable and prompted many to avoid this model except for theoretical studies of optimal performance.In this work, we study the arbitrary and common concurrent writes in the CRCW PRAM model and explore implementation challenges on general-purpose systems. Moreover, we examine current practices for implementing common/arbitrary concurrent writes and propose a new efficient lightweight and thread-safe method to implement concurrent writes through leveraging atomic instructions. To demonstrate the efficacy of our method, we developed OpenMP kernels for classical CRCW PRAM algorithms and provide experimental results and comparisons based on run time performance measured over the x86 multicore architecture. Our results show a performance speedup compared to current practices up to 4.5x across all our benchmarks.

Ghanim, Fady↗