Search NASA⌕ Search

SEARCH · Search NASA

Results for “power flow initialization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Radiatively cooled magnetic reconnection experiments driven by pulsed power

We present evidence for strong radiative cooling in a pulsed-power-driven magnetic reconnection experiment. Two aluminum exploding wire arrays, driven by a 20 MA peak current, 300 ns rise time pulse from the Z machine (Sandia National Laboratories), generate strongly driven plasma flows (MA≈7) with anti-parallel magnetic fields, which form a reconnection layer (SL≈120) at the mid-plane. The net cooling rate far exceeds the Alfvénic transit rate (τcool−1/τA−1≫1), leading to strong cooling of the reconnection layer. We determine the advected magnetic field and flow velocity using inductive probes positioned in the inflow to the layer, and inflow ion density and temperature from analysis of visible emission spectroscopy. A sharp decrease in x-ray emission from the reconnection layer, measured using filtered diodes and time-gated x-ray imaging, provides evidence for strong cooling of the reconnection layer after its initial formation. X-ray images also show localized hotspots, regions of strong x-ray emission, with velocities comparable to the expected outflow velocity from the reconnection layer. These hotspots are consistent with plasmoids observed in 3D radiative resistive magnetohydrodynamic simulations of the experiment. X-ray spectroscopy further indicates that the hotspots have a temperature (170 eV) much higher than the bulk layer (≤75 eV) and inflow temperatures (about 2 eV) and that these hotspots generate the majority of the high-energy (>1 keV) emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hyperaccretion during tidal disruption events: Weakly bound debris envelopes and jets

After the destruction of the star during a tidal disruption event (TDE), the cataclysmic encounter between a star and the supermassive black hole (SMBH) of a galaxy, approximately half of the original stellar debris falls back onto the hole at a rate that can initially exceed the Eddington limit by orders of magnitude. We argue that the angular momentum of this matter is too low to allow it to attain a disk-like configuration with accretion proceeding at a mildly super-Eddington rate, the excess energy being carried away by a combination of radiative losses and radially distributed winds. Instead, we propose that the infalling gas traps accretion energy until it inflates into a weakly bound, quasi-spherical structure with gas extending nearly to the poles. We study the structure and evolution of such 'zero-Bernoulli accretion' flows as a model for the super-Eddington phase of TDEs. We argue that such flows cannot stop extremely super-Eddington accretion from occurring, and that once the envelope is maximally inflated, any excess accretion energy escapes through the poles in the form of powerful jets. We compare the predictions of our model to Swift J1644+57, the putative super-Eddington TDE, and show that it can qualitatively reproduce some of its observed features. Similar models, including self-gravity, could be applicable to gamma-ray bursts from collapsars and the growth of SMBH seeds inside quasi-stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Recovering Residual Xenon Propellant for an Ion Propulsion System

Future nuclear-powered Ion-Propulsion- System-propelled spacecraft such as Jupiter Icy Moon Orbiter (JIMO) will carry more than 10,000 kg of xenon propellant. Typically, a small percentage of this propellant cannot be used towards the end of the mission because of the pressure drop requirements for maintaining flow. For large missions such as JIMO, this could easily translate to over 250 kg of unusable xenon. A proposed system, the Xenon Recovery System (XRS), for recovering almost all of the xenon remaining in the tank, would include a cryopump in the form of a condenser/evaporator that would be alternatively cooled by a radiator, then heated electrically. When the pressure of the xenon in the tank falls below 0.7 MPa (100 psia), the previously isolated XRS will be brought online and the gas from the tank would enter the cryopump that is initially cooled to a temperature below saturation temperature of xenon. This causes xenon liquefaction and further cryopumping from the tank till the cryopump is full of liquid xenon. At this point, the cryopump is heated electrically by small heaters (70 to 80 W) to evaporate the liquid that is collected as high-pressure gas (<7 MPa; 1,000 psia) in an intermediate accumulator. Check valves between the tank and the XRS prevent the reverse flow of xenon during the heating cycle. The accumulator serves as the high-pressure source of xenon gas to the Xenon Feed System (XFS) downstream of the XRS. This cycle is repeated till almost all the xenon is recovered. Currently, this system is being baselined for JIMO.

Ganapathi, Gani↗

Initial Thrust Measurements of Marshall's Ion-ioN Thruster

Electronegative ion thrusters are a variation of traditional gridded ion thruster technology differentiated by the production and acceleration of both positive and negative ions. Benefits of electronegative ion thrusters include the elimination of lifetime-limiting cathodes from the thruster architecture and the ability to generate appreciable thrust from both charge species. While much progress has been made in the development of electronegative ion thruster technology, direct thrust measurements are required to unambiguously demonstrate the efficacy of the concept and support continued development. In the present work, direct thrust measurements of the thrust produced by the MINT (Marshall's Ion-ioN Thruster) are performed using an inverted-pendulum thrust stand in the High-Power Electric Propulsion Laboratory's Vacuum Test Facility-1 at the Georgia Institute of Technology with operating pressures ranging from 4.8 x 10(exp -5) and 5.7 x 10(exp -5) torr. Thrust is recorded while operating with a propellant volumetric mixture ratio of 5:1 argon to nitrogen with total volumetric flow rates of 6, 12, and 24 sccm (0.17, 0.34, and 0.68 mg/s). Plasma is generated using a helical antenna at 13.56 MHz and radio frequency (RF) power levels of 150 and 350 W. The acceleration grid assembly is operated using both sinusoidal and square waveform biases of +/-350 V at frequencies of 4, 10, 25, 125, and 225 kHz. Thrust is recorded for two separate thruster configurations: with and without the magnetic filter. No thrust is discernable during thruster operation without the magnetic filter for any volumetric flow rate, RF forward Power level, or acceleration grid biasing scheme. For the full thruster configuration, with the magnetic filter installed, a brief burst of thrust of approximately 3.75 mN +/- 3 mN of error is observed at the start of grid operation for a volumetric flow rate of 24 sccm at 350 W RF power using a sinusoidal waveform grid bias at 125 kHz and +/- 350 V. Similar bursts in thrust are observed using a square waveform grid bias at 10 kHz and +/- 350 V for volumetric flow rates of 6, 10, and 12 sccm at 150, 350, and 350 W respectively. The only operating condition that exhibits repeated thrust spikes throughout thruster operation is the 24 sccm condition with a 5:1 mixture ratio at 150 W RF power using the 10 kHz square waveform acceleration grid bias. Thrust spikes for this condition measure 3 mN with an error of +/- 2.5 mN. There are no operating conditions tested that show continuous thrust production.

Caruso, Natalie R. S.↗

Evaluating the Suitability for CO 2 Storage at the FutureGen 2.0 Site, Morgan County, Illinois, USA

FutureGen 2.0 site will be the first near-zero emission power plant with fully integrated long-term storage in a deep, non-potable saline aquifer in the United States. The proposed FutureGen 2.0 CO 2 storage site is located in northeast Morgan County, Illinois, U.S.A., forty-eight kilometres from the Meredosia Energy Center where a large-scale oxy-combustion demonstration will be conducted. The demonstration will involve > 90% carbon capture, which will produce more than one million metric tons (MMT) of CO 2 per year. The CO 2 will be compressed at the power plant and transported via pipeline to the storage site. To examine CO 2 storage potential of the site, a 1,467m characterization well (FGA#1) was completed in December 2011. The target reservoir for CO 2 storage is the Mt. Simon Sandstone and Elmhurst Sandstone Member of the lower Eau Claire Formation for a combined thickness of 176 m. Confining beds of the overlying Lombard and Proviso Members (upper Eau Claire Formation) reach a thickness of 126 m. Characterization of the target injection zone and the overlying confining zone was based on wellbore data, cores, and geophysical logs, along with surface geophysical (2-D seismic profiles, magnetic and gravity), and structural data collected during the initial stage of the project . Based on this geological model, 3D simulations of CO 2 injection and redistribution were conducted using STOMP-CO 2 , a multiphase flow and transport simulator. After this characterization stage, it appears that the injection site is a suitable geologic system for CO 2 sequestration and that the injection zone is sufficient to receive up to 33 MMT of CO 2 at a rate of 1.1 MMT/yr. GHGT-11 conference

54 ENVIRONMENTAL SCIENCES↗

NASA Space Launch System Operations Outlook

The National Aeronautics and Space Administration's (NASA) Space Launch System (SLS) Program, managed at the Marshall Space Flight Center (MSFC), is working with the Ground Systems Development and Operations (GSDO) Program, based at the Kennedy Space Center (KSC), to deliver a new safe, affordable, and sustainable capability for human and scientific exploration beyond Earth's orbit (BEO). Larger than the Saturn V Moon rocket, SLS will provide 10 percent more thrust at liftoff in its initial 70 metric ton (t) configuration and 20 percent more in its evolved 130-t configuration. The primary mission of the SLS rocket will be to launch astronauts to deep space destinations in the Orion Multi- Purpose Crew Vehicle (MPCV), also in development and managed by the Johnson Space Center. Several high-priority science missions also may benefit from the increased payload volume and reduced trip times offered by this powerful, versatile rocket. Reducing the lifecycle costs for NASA's space transportation flagship will maximize the exploration and scientific discovery returned from the taxpayer's investment. To that end, decisions made during development of SLS and associated systems will impact the nation's space exploration capabilities for decades. This paper will provide an update to the operations strategy presented at SpaceOps 2012. It will focus on: 1) Preparations to streamline the processing flow and infrastructure needed to produce and launch the world's largest rocket (i.e., through incorporation and modification of proven, heritage systems into the vehicle and ground systems); 2) Implementation of a lean approach to reach-back support of hardware manufacturing, green-run testing, and launch site processing and activities; and 3) Partnering between the vehicle design and operations communities on state-of-the-art predictive operations analysis techniques. An example of innovation is testing the integrated vehicle at the processing facility in parallel, rather than sequentially, saving both time and money. These themes are accomplished under the context of a new cross-program integration model that emphasizes peer-to-peer accountability and collaboration towards a common, shared goal. Utilizing the lessons learned through 50 years of human space flight experience, SLS is assigning the right number of people from appropriate backgrounds, providing them the right tools, and exercising the right processes for the job. The result will be a powerful, versatile, and capable heavy-lift, human-rated asset for the future human and scientific exploration of space.

Hefner, William Keith↗

Modeling of a Solid Oxide Fuel Cell as Part of a Predictive Functional Model for Aerospace Fuel-Cell Systems

This paper will discuss initial efforts at modeling a solid oxide fuel cell (SOFC) for aerospace applications. Fuel cells historically have been used in spacecraft from the Gemini to the Shuttle era for providing spacecraft power with the added benefit of producing water for crew use. However, there are many potential applications for fuel cells and electrolyzers in spaceflight, including oxygen generation, in-situ resource utilization (ISRU) and propellant production. This proof-of-concept model has been developed using a commercial multiphysics modeling software package. Two-dimensional and one-dimensional isothermal models were created based on a certain SOFC design and results were compared to test data from the real system. Local Butler-Volmer kinetic relations were adjusted, and an effective porous medium approach was taken in order to capture how the many interconnects between cells in the gas channels affected fluid flow. The model was able to reproduce polarization curves derived from test data within around 0.02 Volts for a given current density. This model could be adapted to model a solid oxide electrolyzer, proton exchange membrane fuel cell, or other type of fuel cell technology in order to understand how these types of technologies could fit into broader spacecraft designs and advance the capabilities of spaceflight systems.

Mary Lou Nadeau↗

Modeling of a Solid Oxide Fuel Cell as Part of a Predictive Functional Model for Aerospace Fuel-Cell Systems

This paper will discuss initial efforts at modeling a solid oxide fuel cell (SOFC) for aerospace applications. Fuel cells historically have been used in spacecraft from the Gemini to the Shuttle era for providing spacecraft power with the added benefit of producing water for crew use. However, there are many potential applications for fuel cells and electrolyzers in spaceflight, including oxygen generation, in-situ resource utilization (ISRU) and propellant production. This proof-of-concept model has been developed using a commercial multiphysics modeling software package. Two-dimensional and one-dimensional isothermal models were created based on a certain SOFC design and results were compared to test data from the real system. Local Butler-Volmer kinetic relations were adjusted, and an effective porous medium approach was taken in order to capture how the many interconnects between cells in the gas channels affected fluid flow. The model was able to reproduce polarization curves derived from test data within around 0.02 Volts for a given current density. This model could be adapted to model a solid oxide electrolyzer, proton exchange membrane fuel cell, or other type of fuel cell technology in order to understand how these types of technologies could fit into broader spacecraft designs and advance the capabilities of spaceflight systems.

Mary Lou Nadeau↗

Modeling of a Solid Oxide Fuel Cell as Part of a Predictive Functional Model for Aerospace Fuel-Cell Systems

This paper will discuss initial efforts at modeling a solid oxide fuel cell (SOFC) for aerospace applications. Fuel cells historically have been used in spacecraft from the Gemini to the Shuttle era for providing spacecraft power with the added benefit of producing water for crew use. However, there are many potential applications for fuel cells and electrolyzers in spaceflight, including oxygen generation, in-situ resource utilization (ISRU) and propellant production. This proof-of-concept model has been developed using a commercial multiphysics modeling software package. Two-dimensional and one-dimensional isothermal models were created based on a certain SOFC design and results were compared to test data from the real system. Local Butler-Volmer kinetic relations were adjusted, and an effective porous medium approach was taken in order to capture how the many interconnects between cells in the gas channels affected fluid flow. The model was able to reproduce polarization curves derived from test data within around 0.02 Volts for a given current density. This model could be adapted to model a solid oxide electrolyzer, proton exchange membrane fuel cell, or other type of fuel cell technology in order to understand how these types of technologies could fit into broader spacecraft designs and advance the capabilities of spaceflight systems.

Mary Lou Nadeau↗

Modeling of a Solid Oxide Fuel Cell as Part of a Predictive Functional Model for Aerospace Fuel-Cell Systems

This paper will discuss initial efforts at modeling a solid oxide fuel cell (SOFC) for aerospace applications. Fuel cells historically have been used in spacecraft from the Gemini to the Shuttle era for providing spacecraft power with the added benefit of producing water for crew use. However, there are many potential applications for fuel cells and electrolyzers in spaceflight, including oxygen generation, in-situ resource utilization (ISRU) and propellant production. This proof-of-concept model has been developed using a commercial multiphysics modeling software package. Two-dimensional and one-dimensional isothermal models were created based on a certain SOFC design and results were compared to test data from the real system. Local Butler-Volmer kinetic relations were adjusted, and an effective porous medium approach was taken in order to capture how the many interconnects between cells in the gas channels affected fluid flow. The model was able to reproduce polarization curves derived from test data within around 0.02 Volts for a given current density. This model could be adapted to model a solid oxide electrolyzer, proton exchange membrane fuel cell, or other type of fuel cell technology in order to understand how these types of technologies could fit into broader spacecraft designs and advance the capabilities of spaceflight systems.

Mary Lou Nadeau↗

Recent Developments in the WEC-Sim Open-Source Design Tool: Preprint

WEC-Sim (Wave Energy Converter SIMulator) is an open-source code for simulating wave energy converters, which has been actively developed and applied to simulate a wide variety of device archetypes and has become a popular tool since its initial release in 2014. WEC-Sim is developed jointly by the National Renewable Energy Laboratory (NREL) and Sandia National Laboratories (SNL) within the MATLAB/SIMULINK environment. Figure 1 illustrates a general wave-to-wire model which begins with a deployment site resource characterization, which is used to complete the hydrodynamic simulation of a single WEC (or array), with the power generation profile imported to a grid simulator to understand the influence on the local electrical network. While modelling the entire wave-to-wire is difficult and encompass multiple time scales and physics, WEC-Sim is focused on the hydrodynamics simulation to predict, analyze and optimize WEC dynamics and power performance. WEC-Sim simulations are performed in the time domain based on the radiation and diffraction method using hydrodynamics coefficients derived from boundary element method (BEM) based-frequency-domain potential flow solvers (e.g., WAMIT, NEMOH, Capytaine, or ANSYS-AQWA). Within this level of modeling fidelity, WEC-Sim can handle floating body hydrodynamics, mechanical and electrical power generation methods, advanced control implementation, mooring systems, and other unique applications such as desalination. Table 1 lists additional WEC-Sim functionalities, which are created using prebuilt Simulink blocks and MATLAB scripts that can simulate a wide range of floating systems and the corresponding auxiliary subsystems.

hydrodynamics modeling↗

Applying image processing methods to study hydrodynamic characteristics in a rectangular spouted bed

This paper presents systematic image processing methods for investigating hydrodynamic characteristics in a rectangular spouted bed (30.2 mm × 101.6 mm). The objective is to provide a non-intrusive technique to determine the bed expansion ratio, the jet height and the fountain height due to their significant influence on the hydrodynamics of the entire bed. A high-speed video camera is used in the experiment with Geldart D particles as the bed material. After the image acquisition, image denoising, thresholding, logical and mask operations are applied correspondingly for the boundary discrimination, based on which an algorithm has been developed to determine the bed height successfully. With the discriminated boundary, morphological operations viz. erosion and dilation have been used to accurately determine the jet height and the fountain height. The feasibility of the technique is proven through profiles of bed expansion ratio, jet height and fountain height under three initial bed heights (0.0762 m, 0.102 m, and 0.127 m) for two different nozzle sizes (0.0096 m and 0.0127 m). Depending on the determination of the hydrodynamic characteristics, different flow regimes can be distinguished comprehensively through profiles of the bed expansion ratio and bed pressure drop in combination with the standard deviation of jet/fountain height. The proposed flow regime discrimination verifies the feasibility and effectiveness of the image processing methods in assessing the solids behavior in the spouted beds. Results about the variation of the jet height and the fountain height under current operating conditions as determined by the new technique are also discussed.

20 FOSSIL-FUELED POWER PLANTS↗

Editorial for the Collection "Preparatory Work for the American Wake Experiment (AWAKEN)"

The American WAKE experimeNt (AWAKEN) is a large field campaign focused on gathering observations for improved understanding of atmospheric and wind power plant flow physics, one of the outstanding needs for the wind energy community as described in the Science paper by Veers et al.1 "Grand challenges in wind energy." AWAKEN was planned over several years with an international consortium of numerous stakeholders, including national laboratories, academic researchers, wind turbine manufacturers, and wind farm operators. A highlight of the AWAKEN campaign is the extensive use of remote sensing instrumentation to characterize the atmosphere and its interactions with wind power plants, enabled by recent developments in lidar, radar, and thermodynamic profiling technology. Advanced modeling techniques like mesoscale and large-eddy simulations (LES) also played an important role in the preparation of the experiment and the interpretation of the experimental data collected. This special-topic issue for the Journal of Renewable and Sustainable Energy presents a collection of 12 papers that describe the preparatory work and some initial analyses from the AWAKEN campaign. An overview of the contents of the various papers in this special issue is provided in Sec. II.

17 WIND ENERGY↗

New Developments and Capabilities Within WEC-Sim

WEC-Sim is an open-source software for simulating wave energy converters and has been actively developed and applied since its initial release in 2014 to simulate a wide variety of device archetypes. WEC-Sim is developed jointly by the National Renewable Energy Laboratory and Sandia National Laboratories within the MATLAB/SIMULINK environment. A general wave-to-wire model begins with a deployment site resource characterization, which is used to complete the hydrodynamic simulation of wave energy converters (WEC), with the power generation profile imported to a grid simulator to understand the influence on the local electrical network. While modeling the entire wave-to-wire is difficult and encompasses multiple time scales and physics, WEC-Sim is focused on the hydrodynamics simulation to predict, analyze, and optimize WEC dynamics and power performance. WEC-Sim simulations are performed in the time domain based on the radiation and diffraction method using hydrodynamics coefficients derived from boundary element method (BEM)-based frequency-domain potential flow solvers (e.g., WAMIT, NEMOH, Capytaine, or ANSYS-AQWA). With this level of modeling fidelity, WEC-Sim can handle floating body hydrodynamics, mechanical and electrical power generation methods, advanced control implementation, mooring systems, and other unique applications such as desalination. Additional WEC-Sim functionalities include pre-built Simulink blocks and MATLAB scripts that can simulate a wide range of floating systems and the corresponding auxiliary subsystems. The developers of WEC-Sim continue to release new versions of the software, at least annually, with the latest release in September 2022. These releases include bug fixes, updates to software documentation, as well as new features to expand WEC-Sim's capabilities to model a wide range of WEC concepts. This publication will highlight the new features added to WEC-Sim between versions 4.1.0 to 5.0.1, which spans a 2-year period from June 2020 to September 2022. New features described here include topics such as continuous integration checks, revised Morison Element and nonlinear hydro implementations, run directly from Simulink (required for hardware-in-the-loop execution), BEMIO updates to import Capytaine BEM hydrodynamics, addition of cable blocks, and new wave visualization features.

TIDAL AND WAVE POWER↗

Simulation Framework for Regional Geologic CO 2 Storage Along Arches Province of Midwestern United States

This report presents final technical results for the project Simulation Framework for Regional Geologic CO 2 Storage Infrastructure along Arches Province of the Midwest United States . The Arches Simulation project was a three year effort designed to develop a simulation framework for regional geologic carbon dioxide (CO 2 ) storage infrastructure along the Arches Province through development of a geologic model and advanced reservoir simulations of large-scale CO 2 storage. The project included five major technical tasks: (1) compilation of geologic, hydraulic and injection data on Mount Simon, (2) development of model framework and parameters, (3) preliminary variable density flow simulations, (4) multi-phase model runs of regional storage scenarios, and (5) implications for regional storage feasibility. The Arches Province is an informal region in northeastern Indiana, northern Kentucky, western Ohio, and southern Michigan where sedimentary rock formations form broad arch and platform structures. In the province, the Mount Simon sandstone is an appealing deep saline formation for CO 2 storage because of the intersection of reservoir thickness and permeability. Many CO 2 sources are located in proximity to the Arches Province, and the area is adjacent to coal fired power plants along the Ohio River Valley corridor. Geophysical well logs, rock samples, drilling logs, and geotechnical tests were evaluated for a 500,000 km2 study area centered on the Arches Province. Hydraulic parameters and historical operational information was also compiled from Mount Simon wastewater injection wells in the region. This information was integrated into a geocellular model that depicts the parameters and conditions in a numerical array. The geologic and hydraulic data were integrated into a three-dimensional grid of porosity and permeability, which are key parameters regarding fluid flow and pressure buildup due to CO 2 injection. Permeability data were corrected in locations where reservoir tests have been performed in Mount Simon injection wells. The geocellular model was used to develop a series of numerical simulations designed to support CO 2 storage applications in the Arches Province. Variable density fluid flow simulations were initially run to evaluate model sensitivity to input parameters. Two dimensional, multiple-phase simulations were completed to evaluate issues related to arranging injection fields in the study area. A basin-scale, multiple-phase model was developed to evaluate large scale injection effects across the region. Finally, local scale simulations were also completed with more detailed depiction of the Eau Claire formation to investigate to the potential for upward migration of CO 2 . Overall, the technical work on the project concluded that injection large-scale injection may be achieved with proper field design, operation, siting, and monitoring. Records from Mount Simon injection wells were compiled, documenting more than 20 billion gallons of injection into the Mount Simon formation in the Arches Province over the past 40 years, equivalent to approximately 60 million metric tons CO 2 . The multi-state team effort was useful in delineating the geographic variability in the Mount Simon reservoir properties. Simulations better defined potential well fields, well field arrangement, CO 2 pipeline distribution system, and operational parameters for large-scale injection in the Arches Province. Multiphase scoping level simulations suggest that injection fields with arrays of 9 to 50+ wells may be used to accommodate large injection volumes. Individual wells may need to be separated by 3 to 10 km. Injection fields may require spacing of 25 to 40 km to limit pressure and saturation front interference. Basin-scale multiple-phase simulations in STOMP reflect variability in the Mount Simon. While simulations suggest a total injection rate of 100 million metric tons per year (approximately to a 40% reduction of CO 2 emissions from large point sources across the Arches Province) may be feasible, some areas are more suitable due to favorable geology. Sustainable injection rates were higher in areas where there was higher thickness and reservoir permeability. Distribution of injection across well fields is an effective method to reduce pressure and CO 2 saturation front interference.

54 ENVIRONMENTAL SCIENCES↗

Energy-Storing Cryogenic Carbon Capture™ for Utility and Industrial-scale Processes (Final Report)

This project leverages work completed under funding from previous U.S. Department of Energy (DOE) projects and other sources of funding around the Cryogenic Carbon Capture Process™ (CCC). The purpose of this project is to further develop a perturbation of the CCC process that stores energy called the Cryogenic Carbon Capture™ Energy Storing (CCC-ES) process. The successful completion of the tasks in this project has prepared the CCC-ES process for scaling and developed initial plans and a feasibility analysis for an engineering-scale or small-commercial scale system that can store at least 10 MWh of energy. The specific areas of work in this project are: (1) Develop a conceptual, site-specific integrated process flow diagram: Sustainable Energy Solutions (SES) developed a conceptual, site-specific plan including a process flow diagram for integrating CCC-ES at a specific location. The proposed system was based on a typical engineering-scale CCC system designed to capture 30-50 metric tonnes of CO 2 per day (TPD), with modifications and additional changes and equipment put in place to add the energy storage element to the system. The 30-50 TPD scale corresponds to the required 10 MWh of stored energy. This task includes updating simulation software for transient analysis. SES also coordinated with the Jim Bridger Power Plant in Point of Rocks, Wyoming to get site-specific data. Using these data, SES completed site-specific preliminary process flow diagrams, estimated capital and operating costs for the CCC-ES system, and used the upgraded software package to estimate the primary figures of merit. (2) Complete a technoeconomic analysis (TEA): SES completed a full-scale TEA of the CCC-ES system to meet specific success criteria. This TEA used process information from the host site selected above. (3) Technology and data gap assessment for the CCC-ES process: As part of the technology gap assessment, SES performed an assessment of the best alternative energy storage solutions including figures of merit and operational strengths and weaknesses. SES then compared the proposed system with a discussion of how it addresses the weaknesses of alternative systems, showing for example a cost of stored energy at less than $50/MWh and with a roundtrip efficiency of greater than 95%. This assessment includes technical and other risk analyses and technology gaps with research and development needs to commercialize the process by 2030. Finally, work includes a commercialization roadmap/development pathway outlining the major milestones to move to a commercially operating CCC-ES system. (4) Phase II pre-FEED project plan: SES completed a project plan for the Phase II pre-FEED analysis using the same host site as in the Phase I conceptual study.

03 NATURAL GAS↗

Variable-Speed Power-Turbine Research at Glenn Research Center

The main rotors of the NASA Large Civil Tilt-Rotor (LCTR) notional vehicle operate over a wide speed-range, from 100 percent at takeoff to 54 percent at cruise. The variable-speed power turbine (VSPT) offers one approach by which to effect this speed variation. VSPT aerodynamics challenges include high work factors at cruise, wide (40 to 60 ) incidence-angle variations in blade and vane rows over the speed range, and operation at low Reynolds numbers. Rotordynamics challenges include potential responsiveness to shaft modes within the 50 percent VSPT speed-range. A research effort underway at NASA Glenn Research Center, intended to address these key aerodynamic and rotordynamic challenges, is described. Conceptual design and 3-D multistage RANS and URANS analyses, conducted internally and under contract, provide expected VSPT sizing, stage-count, performance and operability information, and maps for system studies. Initial steps toward experimental testing of incidence-tolerant blading in a transonic linear cascade are described, and progress toward development/improvement of a simulation capability for multistage turbines with low Reynolds number transitional flow is summarized. Preliminary rotordynamics analyses indicate that viable concept engines with 50 percent VSPT shaft-speed range. Assessments of potential paths toward VSPT component-level testing are summarized.

Welch, Gerard E.↗

Thermodynamic Model and Initial Experimental Investigation of Air Dehumidification through Electrically Charged Vapor Capturing Electrostatic Droplets

The removal of water vapor from the air to reduce relative humidity is a well known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation with the goal to reduce the energy consumption associated with dehumidification. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. In this thesis, a broad theoretical investigation to study the electrostatically enhanced condensation processes was carried out. These processes consist of the use of highly charged particles, preferably highly charged water droplets to attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. The electrical charge promotes the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation on curved surfaces and, consequently, the equilibrium between evaporation and condensation is shifted towards condensation. This investigation resulted in the development of a thermodynamics model, which was able to predict an effective size range of the charged droplets for optimal dehumidification, under ideal conditions. The range resulted in about 2 to 4 m in diameter, while the electrical charge was kept to the maximum limit predicted by the Rayleigh model. A sensitivity analysis on the variation of the size and the charge of the charged droplets was also performed. In terms of dehumidification rates, when six electrospray heads, i.e. the maximum number of heads tested in the experimental campaign, were considered, the model predicted very limited rates, way lower than the target of this research, i.e. a dehumidification rate in terms of relative humidity of 5 % with an air flow rate of 5 cfm. While ways to increase this rate existed, their implementation proved difficult for this initial investigation. According to the requirements predicted by the model, the use of electrosprays appeared the most suitable solution for the production of small but highly charged droplets. The electrospray features and operational modes were studied in detail and an electrospray assembly was designed to be tested in this initial experimental investigation. For this initial investigation, an experimental system was designed and built to validate the thermodynamics model and with the goal to achieve a dehumidification rate of 5 % in terms of relative humidity with an air flow rate of 5 cfm. The experimental system consisted of a wind tunnel test apparatus, dew point sensors, thermocouples for temperature measurements, pressure sensors and other devices. The experimental system was equipped with a computerized data acquisition and storage system. The system was suitable to evaluate the air water content differential before and after the test section where the electrospray heads were installed. The air water content differential was evaluated in terms of the ∆ω/ω_1 ratio, to eliminate the dependence on the dry bulb temperature along the test apparatus. This work presented initial experimental data for electrostatically enhanced dehumidification processes. Working parameters, such as air and water flow rates, high voltage potentials and polarity, deionized water types with different electrical conductivity, were varied to find the best combination for an improved dehumidification. With the set up used and the conditions considered, it was never possible to achieve a 5 % dehumidification rate with 5 cfm. In general, the dehumidification rate was always limited and lower than 1 % for all the air flow rates considered and mainly within the uncertainty of the dew point sensors. These results confirmed the already limited predictions of the thermodynamics model, for ideal conditions and the interesting and promising results obtained in some experimental investigations available in the open literature were not achievable in this thesis. The more probable reasons were the higher air flow rates considered and the complete absence of the use of cooling power, which was mainly implemented to facilitate the vapor condensation.

Morcelli, Stefano↗