Search NASA⌕ Search

SEARCH · Search NASA

Results for “replacement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Replaceable Sensor System for Bioreactor Monitoring

A sensor system was proposed that would monitor spaceflight bioreactor parameters. Not only will this technology be invaluable in the space program for which it was developed, it will find applications in medical science and industrial laboratories as well. Using frequency-domain-based fluorescence lifetime technology, the sensor system will be able to detect changes in fluorescence lifetime quenching that results from displacement of fluorophorelabeled receptors bound to target ligands. This device will be used to monitor and regulate bioreactor parameters including glucose, pH, oxygen pressure (pO2), and carbon dioxide pressure (pCO2). Moreover, these biosensor fluorophore receptor-quenching complexes can be designed to further detect and monitor for potential biohazards, bioproducts, or bioimpurities. Biosensors used to detect biological fluid constituents have already been developed that employ a number of strategies, including invasive microelectrodes (e.g., dark electrodes), optical techniques including fluorescence, and membrane permeable systems based on osmotic pressure. Yet the longevity of any of these sensors does not meet the demands of extended use in spacecraft habitat or bioreactor monitoring. It was therefore necessary to develop a sensor platform that could determine not only fluid variables such as glucose concentration, pO2, pCO2, and pH but can also regulate these fluid variables with controlled feedback loop.

Mayo, Mike↗

The Revised Space Environment Models in CREME-MC: A Replacement for CREME96

The CREME96 model has been available on the WWW for more than 10 years now. While principally for the estimation of radiation effects on spacecraft electronics, it contains space radiation environment models that have been used for instrument design calculations, estimation of instrumental background, estimation of radiation hazards and many other purposes. Because of the evolution of electronic part design we have found it necessary to revise CREME96, creating CREME-MC. As part of this revision, we are revising and extending the environmental models in CREME96. This talk will describe the revised radiation environment models that are being made available in CREME-MC

Adams, James H., Jr.↗

Visual Image Sensor Organ Replacement: Implementation

Method and system for enhancing or extending visual representation of a selected region of a visual image, where visual representation is interfered with or distorted, by supplementing a visual signal with at least one audio signal having one or more audio signal parameters that represent one or more visual image parameters, such as vertical and/or horizontal location of the region; region brightness; dominant wavelength range of the region; change in a parameter value that characterizes the visual image, with respect to a reference parameter value; and time rate of change in a parameter value that characterizes the visual image. Region dimensions can be changed to emphasize change with time of a visual image parameter.

Maluf, A. David↗

PCB-Caulk Replacement Project Johnson Space Center Houston, TX

Wet method reduced exposure by minimizing overall respirable particulate release. Dry method didn't introduce delays for primer/caulk application. Removed caulks came in many forms, from dry powdery to tarry sticky. Varying textures were not sampled or packaged differently. During the course of the project, EPA modified recommended practices to include full containment for exterior caulk removal. Changes are ongoing. Initial recommendations were directed to school buildings. EPA is researching risks due to caulk. Exposure guidance lacking except for 2 of 209 PCB congeners. Work was safely completed on schedule and under budget.

Young, William M.↗

Ionic Liquids to Replace Hydrazine

A method for developing safe, easy-to-handle propellants has been developed based upon ionic liquids (ILs) or their eutectic mixtures. An IL is a binary combination of a typically organic cation and anion, which generally produces an ionic salt with a melting point below 100 deg C. Many ILs have melting points near, or even below, room temperature (room temperature ionic liquids, RTILs). More importantly, a number of ILs have a positive enthalpy of formation. This means the thermal energy released during decomposition reactions makes energetic ILs ideal for use as propellants. In this specific work, to date, a baseline set of energetic ILs has been identified, synthesized, and characterized. Many of the ILs in this set have excellent performance potential in their own right. In all, ten ILs were characterized for their enthalpy of formation, density, melting point, glass transition point (if applicable), and decomposition temperature. Enthalpy of formation was measured using a microcalorimeter designed specifically to test milligram amounts of energetic materials. Of the ten ILs characterized, five offer higher Isp performance than hydrazine, ranging between 10 and 113 seconds higher than the state-of-the-art propellant. To achieve this level of performance, the energetic cations 4- amino-l,2,4-triazolium and 3-amino-1,2,4-triazolium were paired with various anions in the nitrate, dicyanamide, chloride, and 3-nitro-l,2,4-triazole families. Protonation, alkylation, and butylation synthesis routes were used for creation of the different salts.

Koelfgen, Syri↗

Laser Diffraction Techniques Replace Sieving for Lunar Soil Particle Size Distribution Data

Sieving was used extensively until 1999 to determine the particle size distribution of lunar samples. This method is time-consuming, and requires more than a gram of material in order to obtain a result in which one may have confidence. This is demonstrated by the difference in geometric mean and median for samples measured by [1], in which a 14-gram sample produced a geometric mean of approx.52 micrometers, whereas two other samples of ~1.5 grams resulted in gave means of approx.63 and approx.69 micrometers. Sample allocations for sieving are typically much smaller than a gram, and many of the sample allocations received by our lab are 0.5 to 0.25 grams in mass. Basu [2] has described how the finest fraction of the soil is easily lost in the sieving process, and this effect is compounded when sample sizes are small.

Cooper, Bonnie L.↗

Replacing the CCSDS Telecommand Protocol with Next Generation Uplink

Better performing Forward Error Correction on the forward link along with adequate power in the data open an uplink operations trade space that enable missions to: Command to greater distances in deep space (increased uplink margin) Increase the size of the payload data (latency may be a factor) Provides space for the security header/trailer of the CCSDS Space Data Link Security Protocol Note: These higher rates could be used for relief of emergency communication margins/rates and not limited to improving top-end rate performance. A higher performance uplink could also reduce the requirements on flight emergency antenna size and/or the performance required from ground stations. Use of a selective repeat ARQ protocol may increase the uplink design requirements but the resultant development is deemed acceptable, due the factor of 4 to 8 potential increase in uplink data rate.

Low Density Parity Check (LDPC)↗

Replacing the Polarizer Wheel with a Polarization Camera to Increase the Temporal Resolution and Reduce the Overall Complexity of a Solar Coronagraph

Experiments that require linearly polarized brightness measurements, traditionally have obtained three successive images through a linear polarizer that is rotated through three well-defined angles and the images are combined to get the linearly polarized brightness. This technique requires a mechanism to hold the linear polarizer in place and to precisely turn it through the three angles. Obviously, the temporal resolution is lost in such a scenario, since the three images that are used to derive the linearly polarized brightness are taken at three different times. Specifically, in a dynamic corona that is in constant reshaping of its structures, the linearly polarized brightness image produced in this manner may not yield true values all around the corona. In this regard, with the advent of the polarization camera, the linearly polarized brightness can be measured from a single image. This also eliminates the need for a linear polarizer and the associated rotator mechanisms and can contribute toward lower weight, size, power requirements, overall risk of the instrument, and most importantly, increase the temporal resolution. We evaluate the capabilities of a selected polarization camera and how these capabilities could be tested in a ground experiment conducted in conjunction with a total solar eclipse. The ground experiment requires the measurement of the linearly polarized brightness, also known as K-corona, in a corona that also contains unpolarized brightness, known as F-corona, in order to measure three important physical properties pertaining to coronal electrons, namely, the electron density, electron temperature, and the electron speed.

Reginald, Nelson L.↗

Summary of Space Environment Magnetometer and Particle Replacement Experiment (SEMPRE) Study

As part of the GOES-R series follow on architecture study following the NOAA Satellite Observing System Architecture (NSOSA) study, a study team evaluated the feasibility of accommodating the GOES in-situ instruments (Magnetometer and Particle Detectors) on a dedicated spacecraft with no impact to the overall baseline mission cost assuming two large observatories. The accommodations cost on a primary operational type observatory are non-negligible requiring: a large non-magnetic boom to reduce the impact of the spacecraft interference on the magnetometer; and strict contamination control and magnetic cleanliness to prevent magnetic contamination near the magnetometers. These, along with the additional interface complexities greatly increase the cost of larger spacecraft by extending integration time with a large marching army. By contrast, a dedicated mission provides flexibility in location and refresh rate not afforded when these sensors are launched as secondary payloads. This study performed an informal industry survey of small form-factor instruments currently flying or in process of being developed. The study identified three potential particle detector suites and multiple magnetometers that will satisfy the requirements while having low enough volume and mass to allow accommodation on a rideshare class spacecraft. Using the largest of the identified particle detector suites, the Goddard Space Flight Center Mission Design Lab developed a design for a rideshare spacecraft that will accommodate the particle detector suite and magnetometer. The cost of the spacecraft, based on multiple cost models, is comparable to the cost of accommodating the magnetometer and particle detector suite on two (East and West) larger main observatories.

Todirita, Monica↗