Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Improved molecular level identification of organic compounds using comprehensive two-dimensional chromatography, dual ionization energies and high resolution mass spectrometry

A new analytical methodology combining comprehensive two-dimensional gas chromatography (GC×GC), dual ionization energies and high resolution time of flight mass spectrometry has been developed that improves molecular level identification of organic compounds in complex environmental samples. GC×GC maximizes compound separation providing cleaner mass spectra by minimizing erroneous fragments from interferences and co-eluting peaks. Traditional electron ionization (EI, 70 eV) provides MS fragmentation patterns that can be matched to published EI MS libraries while vacuum ultraviolet photoionization (VUV, 10.5 eV) yields MS with reduced fragmentation enhancing the abundance of the molecular ion providing molecular formulas when combined with high resolution mass spectrometry. We demonstrate this new approach by applying it to a sample of organic aerosol. In this sample, 238 peaks were matched to EI MS library data with FM ≥ 800 but a fifth (42 compounds) were determined to be incorrectly identified because the molecular formula was not confirmed by the VUV MS data. This highlights the importance of using a complementary technique to confirm compound identifications even for peaks with very good matching statistics. In total, 171 compounds were identified by EI MS matching to library spectra with confirmation of the molecular formula from the high resolution VUV MS data and were not dependent on the matching statistics being above a threshold value. A large number of unidentified peaks were still observed with FM < 800, which in routine analysis would typically be neglected. Where possible, these peaks were assigned molecular formulas from the VUV MS data (211 in total). In total, the combination of EI and VUV MS data provides more than twice as much molecular level peak information than traditional approaches and improves confidence in the identification of individual organic compounds. The molecular formula data from the VUV MS data was used, in conjunction with GC×GC retention times and the observed EI MS, to generate a new, searchable EI MS library compatible with the standard NIST MS search program. This library is deliberately dynamic and editable so that other end users can add new entries and update existing entries as new information becomes available.A new analytical methodology has been developed to improve molecular level identification of organic compounds in complex samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Use of an Open Port Sampling Interface Coupled to Electrospray Ionization for the On-Line Analysis of Organic Aerosol Particles

A simple design for an open port sampling interface coupled to electrospray ionization (OPSI-ESI) is presented for the analysis of organic aerosols. The design uses minimal modifications to a Bruker electrospray (ESI) emitter to create a continuous flow, self-aspirating open port sampling interface. Considerations are presented for introducing aerosol to the open port sampling interface including aerosol gas flow and solvent flow rates. The device has been demonstrated for use with an aerosol of nicotine as well as aerosol formed in the pyrolysis of biomass. Upon comparison with extractive electrospray ionization (EESI), this device has similar sensitivity with increased reproducibility by nearly a factor of three. The device has the form factor of a standard Bruker/Agilent ESI emitter and can be used without any further instrument modifications. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-Wavelength Dielectrometer (MWD) Sensor For Planetary Subsurface Exploration

NASA's mission to Moon, Mars, and Beyond envisions landing of a light weight measurement platform on the planetary surface. The Multi-Wavelength Dielectrometer (MWD) on-board consists of essential electronics and metallic plates acting as electrodes attached to the body of such platform. An electric signal applied to one of the electrodes acting as a cathode sets up electric field pattern (in the soil medium) between the cathode and other electrodes acting as anodes. The electrodes are swept through multiple wavelengths (1Hz-1MHz) and the electric current drawn by the electrodes is measured at each frequency. The measured current whose amplitude and phase depend upon electrode spacing, dielectric constant of the subsurface soil, and the frequency is then used to estimate electrical properties of the soil. In this paper the MWD sensor that will measure the dielectric properties of Moon/Mars s soil is presented. A procedure to process the MWD measured data for extracting the soil properties is also described. Assuming the subsurface soil structure as multilayer strata having varying electric properties, an electric equivalent circuit of the multiple electrodes configuration placed on a multi-layer soil sample is obtained. The current drawn by the equivalent circuit from the low frequency signal generator is then calculated. By minimizing the difference between the model s estimated current and measured MWD data the electric properties of soil samples are extracted. Experimental and simulated results will be presented to validate the proposed procedure for extracting soil properties.

Deshpande, Manohar↗

Automation of Laser Plasma Focused Ion Beam Microscopy for Next-Gen Energy Materials

Automation can revolutionize the use of ultrafast laser ablation and plasma-focused ion beam (PFIB) techniques for high-throughput, reproducible cross-sectioning and various sample preparation in materials characterization. As these methods become essential for analyzing complex energy materials and next-generation devices, efficient, standardized workflows are needed to minimize variability and enhance precision. This work highlights our advancements in developing automated processes for sample preparation that integrates machine learning, workflow optimization, and large-scale data acquisition to improve efficiency and scalability in applications such as electrolyzers, photovoltaic cells, and microelectronics. To streamline cross-sectioning and lamella fabrication, we have implemented fully automated workflows that standardize laser ablation and PFIB milling sequences. These workflows incorporate pre-programmed protocols for material removal, alignment, and thinning, reducing user intervention and ensuring consistency across different sample types. Machine learning algorithms further enhance automation by predicting optimal milling strategies and adapting parameters based on material properties and sectioning requirements. This approach significantly improves throughput while maintaining the structural integrity of prepared samples for high-resolution imaging and analysis, including transmission electron microscopy. Beyond sample preparation, our automation platform enables the acquisition of large, high-resolution datasets through serial sectioning, image alignment, and 3D reconstruction. These automated routines facilitate multi-scale characterization, capturing structural and compositional details from the nanoscale to the device level. By reducing variability and increasing efficiency, our automated approach enhances defect analysis, failure diagnostics, and process optimization, accelerating advancements in materials research and device engineering.

36 MATERIALS SCIENCE↗

Cryo-STEM Tomography with Inpainting

Traditionally, microscopists have worked with the Nyquist-Shannon theory of sampling, which states that to be able to reconstruct the image fully it needs to be sampled at a rate of at least twice the highest spatial frequency in the image. This sampling rate assumes that the image is sampled at regular intervals and that every pixel contains information that is crucial for the image (it even assumes that noise is important). Images in general, and especially low dose S/TEM images, contain significantly less information than can be encoded by a grid of pixels (which is why image compression works). Mathematically speaking, the image data has a low dimensional or sparse representation. Through the application of compressive sensing methods [1,2,3] this representation can be found using pre-designed measurements that are usually random for implementation simplicity. These measurements and the compressive sensing reconstruction algorithms have the added benefit of reducing noise. This reconstruction approach can be extended into higher dimensions, whereby the random sampling in each 2-D image can be extended into: a sequence of tomographic projections (i.e. tilt images); a sequence of video frames (i.e. incorporating temporal resolution and dynamics); spectral resolution (i.e. energy filtering an image to see the distribution of elements); and ptychography (i.e. sampling a full diffraction image at each location in a 2-D grid across the sample). This approach has been employed experimentally for materials science samples requiring low-dose imaging [2], and can be readily applied to biological samples. Figure 1 shows the resolution possible in a complex biological system, mouse pancreatic islet beta cells [4], when tomogram slices are reconstructed using subsampling. Reducing the number of pixels (1/6 pix and 1/3*1/3) shows minimal degradation compared to the reconstructions using all pixels (all data and 1/3 tilt). Although subsampling 1/6 of the tilts (1/6 of overall dose) degrades the reconstruction to the point that the cellular structures cannot be identified. Using 1/3 of both the pixels and the tilts provides a high quality image at 1/9 the overall dose even for this most basic and rapid demonstration of the CS methods. Figure 2 demonstrates the theoretical tomogram reconstruction quality (vertical axis) as undersampling (horizontal axis) is increased; we examined subsampling pixels and tilt-angles individually and a combined approach in which both pixels and tilts are sub-sampled. Note that subsampling pixels maintains high quality reconstructions (solid lines). Using the inpainting algorithm to obtain tomograms can automatically reduce the dose applied to the system by an order of magnitude. Perhaps the best way to understand the impact is to consider that by using inpainting (and with minimal hardware changes), a sample that can normally withstand a dose of ~10 e/Å2 can potentially be imaged with an “equivalent quality” to a dose level of 103 e/Å2. To put this in perspective, this is approaching the dose level used for the most advanced images, in terms of spatial resolution, for inorganic systems. While there are issues for biological specimens beyond dose (structural complexity being the most important one), this sampling approach allows the methods that are traditionally used for materials science to be applied to biological systems [5]. References: [1] A Stevens, H Yang, L Carin et al. Microscopy 63(1), (2014), pp. 41. [2] L Kovarik, A Stevens, A Liyu et al. Appl. Phys. Lett. 109, 164102 (2016) [3] A Stevens, L Kovarik, P Abellan et al. Adv. Structural and Chemical Imaging 1(10), (2015), pp. 1. [4] MD Guay, W Czaja, MA Aronova et al. Scientific Reports 6, 27614 (2016) [5] Supported by the Chemical Imaging, Signature Discovery, and Analytics in Motion Initiatives at PNNL. PNNL is operated by Battelle Memorial Inst. for the US DOE; contract DE-AC05-76RL01830.

Stevens, Andrew↗

A new Diffractometer for Studies of Liquid-Liquid Interfaces

We have designed a novel, dedicated diffractometer for surface x-ray scattering studies of liquid-liquid and liquid-gas interfaces for the PETRA III High Resolution Diffraction Beamline. Using a double crystal beam-tilter in Bragg geometry this new instrument enables reflectivity and grazing incidence diffraction investigations without moving the sample, which is mechanically decoupled from the rest of the diffractometer. This design minimizes external excitation of surface vibrations, a key prerequisite for studies of liquid interfaces. The instrument operates over the energy range 6.4 keV to 30 keV, the higher energy range being optimal for penetration through liquid sample environments. Vertical momentum transfer up to q{sub z} 2.5 A{sup -1} and lateral q{sub ||} up to 4 A{sup -1}will be available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Open Specy 1.0: Automated (Hyper)spectroscopy for Microplastics

Microplastic spectral analysis is one of the most time-consuming processes in studying microplastic pollution, often requiring days per sample. Researchers are transitioning to automated batch and hyperspectral image analysis techniques to enhance efficiency. Open Specy, initially aimed at manual single-spectrum analysis, has now integrated automated methods. This updated version, Open Specy 1.0, introduces several new features, including two algorithms for automated processing (smoothing and particle compression), an extensive library containing over 40,000 open-source Raman and FTIR spectra, and two machine learning classifiers (logistic regression and k medoids) developed from this library. Furthermore, it includes a revamped user interface, an R package, and a benchmark data set for testing future advancements in automated techniques. Researchers evaluated various configurations for hyperspectral smoothing, particle identification, compression, and splitting, to achieve combined recovery rates between 50 and 150% particle counts, identities, and sizes with a coefficient of variation (CV) of less than 40% (the accredited standard). Mean absorbance times the standard deviation provided a consistent particle identification. Hyperspectral smoothing led to a 96% combined recovery rate and reduced variability (CV = 38%) compared to the 86% recovery (CV = 83%) of nonsmoothed controls. Additionally, compressing spectra for particles was significantly faster (>3x) and showed similar accuracy but with reduced variability than processing each pixel individually. Key challenges persist in automating spectral analysis, particularly in refining particle splitting algorithms, and improving identification routines to minimize false positives and negatives. In conclusion, new methods in sample preparation for better stabilization and dispersion of particles could overcome some of these issues.

13 HYDRO ENERGY↗

Sampling Errors in Monthly Rainfall Totals for TRMM and SSM/I, Based on Statistics of Retrieved Rain Rates and Simple Models

Estimates from TRMM satellite data of monthly total rainfall over an area are subject to substantial sampling errors due to the limited number of visits to the area by the satellite during the month. Quantitative comparisons of TRMM averages with data collected by other satellites and by ground-based systems require some estimate of the size of this sampling error. A method of estimating this sampling error based on the actual statistics of the TRMM observations and on some modeling work has been developed. "Sampling error" in TRMM monthly averages is defined here relative to the monthly total a hypothetical satellite permanently stationed above the area would have reported. "Sampling error" therefore includes contributions from the random and systematic errors introduced by the satellite remote sensing system. As part of our long-term goal of providing error estimates for each grid point accessible to the TRMM instruments, sampling error estimates for TRMM based on rain retrievals from TRMM microwave (TMI) data are compared for different times of the year and different oceanic areas (to minimize changes in the statistics due to algorithmic differences over land and ocean). Changes in sampling error estimates due to changes in rain statistics due 1) to evolution of the official algorithms used to process the data, and 2) differences from other remote sensing systems such as the Defense Meteorological Satellite Program (DMSP) Special Sensor Microwave/Imager (SSM/I), are analyzed.

Bell, Thomas L.↗

STAR CLUSTERS IN M33: UPDATED UBVRI PHOTOMETRY, AGES, METALLICITIES, AND MASSES

The photometric characterization of M33 star clusters is far from complete. In this paper, we present homogeneous UBVRI photometry of 708 star clusters and cluster candidates in M33 based on archival images from the Local Group Galaxies Survey, which covers 0.8 deg{sup 2} along the galaxy's major axis. Our photometry includes 387, 563, 616, 580, and 478 objects in the UBVRI bands, respectively, of which 276, 405, 430, 457, and 363 do not have previously published UBVRI photometry. Our photometry is consistent with previous measurements (where available) in all filters. We adopted Sloan Digital Sky Survey ugriz photometry for complementary purposes, as well as Two Micron All Sky Survey near-infrared JHK photometry where available. We fitted the spectral-energy distributions of 671 star clusters and candidates to derive their ages, metallicities, and masses based on the updated PARSEC simple stellar populations synthesis models. The results of our χ{sup 2} minimization routines show that only 205 of the 671 clusters (31%) are older than 2 Gyr, which represents a much smaller fraction of the cluster population than that in M31 (56%), suggesting that M33 is dominated by young star clusters (<1 Gyr). We investigate the mass distributions of the star clusters—both open and globular clusters—in M33, M31, the Milky Way, and the Large Magellanic Cloud. Their mean values are log (M {sub cl}/M {sub ☉}) = 4.25, 5.43, 2.72, and 4.18, respectively. The fraction of open to globular clusters is highest in the Milky Way and lowest in M31. Our comparisons of the cluster ages, masses, and metallicities show that our results are basically in agreement with previous studies (where objects in common are available); differences can be traced back to differences in the models adopted, the fitting methods used, and stochastic sampling effects.

79 ASTRONOMY AND ASTROPHYSICS↗

Metallographic Characterization of Wrought Depleted Uranium

Metallographic characterization was performed on wrought depleted uranium (DU) samples taken from the longitudinal and transverse orientations from specific locations on two specimens. Characterization of the samples included general microstructure, inclusion analysis, grain size analysis, and microhardness testing. Comparisons of the characterization results were made to determine any differences based on specimen, sample orientation, or sample location. In addition, the characterization results for the wrought DU samples were also compared with data obtained from the metallographic characterization of cast DU samples previously characterized. No differences were observed in microstructure, inclusion size, morphology, and distribution, or grain size in regard to specimen, location, or orientation for the wrought depleted uranium samples. However, a small difference was observed in average hardness with regard to orientation at the same locations within the same specimen. The longitudinal samples were slightly harder than the transverse samples from the same location of the same specimen. This was true for both wrought DU specimens. Comparing the wrought DU sample data with the previously characterized cast DU sample data, distinct differences in microstructure, inclusion size, morphology and distribution, grain size, and microhardness were observed. As expected, the microstructure of the wrought DU samples consisted of small recrystallized grains which were uniform, randomly oriented, and equiaxed with minimal twinning observed in only a few grains. In contrast, the cast DU microstructure consisted of large irregularly shaped grains with extensive twinning observed in most grains. Inclusions in the wrought DU samples were elongated, broken and cracked and light and dark phases were observed in some inclusions. The mean inclusion area percentage for the wrought DU samples ranged from 0.08% to 0.34% and the average density from all wrought DU samples was 1.62E+04/cm 2 . Inclusions in the cast DU samples were equiaxed and intact with light and dark phases observed in some inclusions. The mean inclusion area percentage for the cast DU samples ranged from 0.93% to 1.00% and the average density from all wrought DU samples was 2.83E+04/cm 2 . The average mean grain area from all wrought DU samples was 141 μm 2 while the average mean grain area from all cast DU samples was 1.7 mm2. The average Knoop microhardness from all wrought DU samples was 215 HK and the average Knoop microhardness from all cast DU samples was 264 HK.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Constraints on the surface materials of Ryugu from spectral and water analysis of experimentally-heated CI carbonaceous chondrite

We performed heating experiments of the Orgueil CI chondrite in vacuum conditions at fO2 around I/W to evaluate systematic changes in mineralogy, water contents, and visible to infrared spectral features. Our goal is to interpret the spectra of Ryugu, the target C asteroid of the Hayabusa2 mission, because Ryugu shows spectral features similar to partially dehydrated carbonaceous chondrites. However heated carbonaceous chondrites can be easily contaminated by terrestrial water, which makes it almost impossible for laboratory data to be compared with spectra of asteroids directly. Therefore, our heated samples were analyzed without exposure to the air after experimental heating to minimize the effects of terrestrial water. The depth of the 2.7-µm absorption band and the water content of the heated Orgueil form a positive correlation trend which follows the results of experimental heating of CM and Tagish Lake meteorites using our experimental procedures. It is found that 500-°C heated Orgueil sample shows the best spectral match with Ryugu in terms of the low reflectance (~2%) at visible wavelengths and a weak absorption (~10%) at around 2.72 µm owing to survival of Mg-rich phyllosilicates. We suggest that Ryugu might have experienced heating and dehydration at a temperature around 500 °C, after aqueous alteration, and presently contains a small quantity of hydrated minerals equivalent to 1-2 wt.% of water at the surface.

K. Amano↗

Enhancement of induced V polarization due to rough interfaces in polycrystalline V/Fe/V trilayers

The effect of interface roughness on the induced polarization of V in polycrystalline V/Fe/V trilayers was investigated with x-ray magnetic circular dichroism, x-ray resonant magnetic scattering, and polarized neutron reflectometry. Trilayer samples were sputter deposited onto Si substrates at room temperature to minimize interdiffusion. The films were polycrystalline and exhibited an average 0.5 nm root-mean-square interfacial roughness at the Fe/V interfaces. The induced polarization found in V was constrained to the Fe/V interface extending approximately up to 2-3 monolayers into the V and exhibited antiferromagnetic alignment to the Fe layer. A magnetic moment for V ranging between -0.46 and -0.86 {micro}{sub B}/V atom is consistent with the neutron and resonant x-ray data. Notably, this value for structurally rough interfaces is significantly larger than that reported for samples with atomically flat Fe/V interfaces.

36 MATERIALS SCIENCE↗

Effect of Retained Austininte on White Etching Crack Behavior of Carburized AISI 8620 Steel Under Boundary Lubrication

The formation of white etching cracks (WECs) is a dominant failure mode in wind turbine gearbox bearings that can significantly shorten their operating life. Although the phenomenon of WECs has been communicated in the field for more than a decade, the driving mechanisms are still debated, and the impact of proposed mitigation techniques is not quantified. Leading hypotheses to inhibit the formation of WECs center on material solutions, including the use of steel with high levels of retained austenite (RA). The present work aims to explore the impact of RA on the formation of WECs within AISI 8620 steel under boundary lubrication. A three ring-on-roller benchtop test rig was used to replicate WECs in samples with different levels of RA. While varying levels of RA had a minimal effect on time until failure, a significant effect on crack morphology was observed. Additionally, potential underlying mechanisms of White Etching Area formation were elucidated. Under the current test conditions, the microstructural alterations adjacent to the cracks in the lower RA samples were more developed compared to those of the higher RA samples. Additionally, the WEC networks in the high RA samples contained significantly more crack branches than those of the low RA samples.

Bearing failure↗

Algorithm and program for precise determination of unit-cell parameters of single crystal taking into account the sample eccentricity

A technique has been developed to refine the unit-cell parameters of single crystals with minimization of the influence of instrumental errors on the result. The corresponding computational procedure HuberUB is added to the software package of Huber-5042 diffractometer with a point detector and closedcycle helium cryostat Displex DE-202. The parameters of unit cell, its orientation, the goniometer zero angles, the sample eccentricity, the distances in the goniometer, and the radiation wavelength were refined by the nonlinear least-squares method, which allows imposition of constraints on the unit-cell parameters, depending on the crystal symmetry. The technique is approved on a LuB{sub 12} single crystal. The unit-cell parameters are determined in a temperature range of 20–295 K, with an absolute error not larger than 0.0004 Å (the relative error is of ~5 × 10{sup –5}). The estimates of the unit-cell parameters obtained by the proposed method are evidenced to be unbiased. Some specific features of the behavior of parameters in the ranges of 120–140 and 20–50 K are revealed, which correlate with the anomalies of the physical properties of the crystal.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A fixed-target platform for serial femtosecond crystallography in a hydrated environment

For serial femtosecond crystallography at X-ray free-electron lasers, which entails collection of single-pulse diffraction patterns from a constantly refreshed supply of microcrystalline sample, delivery of the sample into the X-ray beam path while maintaining low background remains a technical challenge for some experiments, especially where this methodology is applied to relatively low-ordered samples or those difficult to purify and crystallize in large quantities. This work demonstrates a scheme to encapsulate biological samples using polymer thin films and graphene to maintain sample hydration in vacuum conditions. The encapsulated sample is delivered into the X-ray beam on fixed targets for rapid scanning using the Roadrunner fixed-target system towards a long-term goal of low-background measurements on weakly diffracting samples. As a proof of principle, we used microcrystals of the 24 kDa rapid encystment protein (REP24) to provide a benchmark for polymer/graphene sandwich performance. The REP24 microcrystal unit cell obtained from our sandwiched in-vacuum sample was consistent with previously established unit-cell parameters and with those measured by us without encapsulation in humidified helium, indicating that the platform is robust against evaporative losses. While significant scattering from water was observed because of the sample-deposition method, the polymer/graphene sandwich itself was shown to contribute minimally to background scattering.

36 MATERIALS SCIENCE↗

Enhancing pairwise state-transition weights: A new weighting scheme in simulated tempering that can minimize transition time between a pair of conformational states

Simulated tempering (ST) is a widely used enhancing sampling method for Molecular Dynamics simulations. As one expanded ensemble method, ST is a combination of canonical ensembles at different temperatures and the acceptance probability of cross-temperature transitions is determined by both the temperature difference and the weights of each temperature. One popular way to obtain the weights is to adopt the free energy of each canonical ensemble, which achieves uniform sampling among temperature space. However, this uniform distribution in temperature space may not be optimal since high temperatures do not always speed up the conformational transitions of interest, as anti-Arrhenius kinetics are prevalent in protein and RNA folding. Here, we propose a new method: Enhancing Pairwise State-transition Weights (EPSW), to obtain the optimal weights by minimizing the round-trip time for transitions among different metastable states at the temperature of interest in ST. The novelty of the EPSW algorithm lies in explicitly considering the kinetics of conformation transitions when optimizing the weights of different temperatures. We further demonstrate the power of EPSW in three different systems: a simple two-temperature model, a two-dimensional model for protein folding with anti-Arrhenius kinetics, and the alanine dipeptide. The results from these three systems showed that the new algorithm can substantially accelerate the transitions between conformational states of interest in the ST expanded ensemble and further facilitate the convergence of thermodynamics compared to the widely used free energy weights. We anticipate that this algorithm is particularly useful for studying functional conformational changes of biological systems where the initial and final states are often known from structural biology experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Detailed modeling of the video signal and optimal readout of charge-coupled devices

This paper provides a practical design methodology to calculate an optimal filter for noise reduction in the readout of charge-coupled devices (CCDs) taking into account the charge transfer and feedthroughs due to capacitive coupling in the CCD. A detailed analysis of the dynamics of the video signal and charge transfer is presented, including the circuital modeling of the output stage of the CCD and the dynamics of the electronics in the video chain before the analog-to-digital (AD) converter. This model is used to compute an optimal filter that minimizes the variance of the pixel noise and uses the samples of the charge transfer, before the charge is fully settled. This is necessary to enhance the performance of previous results that also use optimal filters but do not use the transition samples, while also reducing the pixel readout time, resulting in faster readouts. As a proof of concept for the optimal filter, we present in this paper novel experimental results using a Skipper CCD, which has a floating sense node that allows to measure the charge packet an arbitrary number of times. However, this technique can be applied to any CCD that has a readout system that digitally samples the video signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tuning transition metal nanoparticles on a non-traditional support via experimental design

The ability to control metal nanoparticle size and morphology on supported catalysts is crucial for optimizing catalytic performance in targeted applications. Here, this work presents a systematic approach for tuning Ni particle and crystallite size on an unconventional, low-porosity silica fume support through select thermal treatments. The catalyst was synthesized via the deposition of nickelocene onto silica fume, resulting in well-dispersed Ni nanoparticles. A face-centered central composite design was employed to systematically assess the effects of time, temperature, and sintering gas environment on metal particle growth. The results demonstrate that the sintering gas environment is the primary factor governing particle and crystallite evolution, with temperature as the next most significant influence. Nickel nanoparticles sintered at temperatures of 650 °C and above under inert conditions exhibited substantial growth and polycrystalline structures, whereas samples treated in oxidative environments formed NiO, restricting particle mobility. Minimally oxidative (500 ppm O₂) environments facilitated rapid sintering while effectively removing residual ligands from the one-step nickelocene deposition process. Extensive structural characterization via a combination of scanning transmission electron microscopy, X-ray diffraction, hydrogen temperature programmed reduction, and small-angle X-ray scattering revealed that oxidative treatments enhanced metal-support interactions, as evidenced by increased reduction temperatures and narrower particle size distributions. These findings establish quantitative relationships between sintering parameters and Ni nanoparticle characteristics, providing a framework for rational catalyst design through controlled thermal treatments. This methodology is broadly applicable to other catalytic systems and provides a quantitative foundation for catalyst design.

CVD↗