Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Rapid monitoring of fermentations: a feasibility study on biological 2,3-butanediol production

2,3-butanediol (2,3-BDO) is an economically important platform chemical that can be produced by the fermentation of sugars using an engineered strain of Zymomonas mobilis . These fermentations require continuous monitoring and modification of fermentation conditions to maximize 2,3-BDO yields and minimize the production of the undesired coproducts glycerol and acetoin. Because of the time required for sampling and off-line chromatographic measurement of fermentation samples, the ability of fermentation scientists to modify fermentation conditions in a timely manner is limited. The goal of this study was to test if near-infrared spectroscopy (NIRS) along with multivariate statistics could reduce the time needed for this analysis and enable real-time monitoring and control of the fermentation. In this work we developed partial least squares (PLS) calibration models to predict the concentrations of glucose, xylose, 2,3-BDO, acetoin, and glycerol in fermentations via NIRS using two different spectrometers and two different spectroscopy modalities. We first evaluated the feasibility of rapid NIRS monitoring through experiments where we measured the signals from each analyte of interest and built NIRS-based PLS models using spectra from synthetic samples containing uncorrelated concentrations of these analytes. All analytes showed unique spectral signatures, and this initial modeling showed that all analytes could be detected simultaneously. We then began work with samples from laboratory fermentation experiments and tested the feasibility of regression model development across two spectral collection modalities (at-line and on-line) and two instruments: a laboratory-grade instrument and a low-cost instrument with a more limited spectral range. All modalities showed promise in the ability to monitor Z. mobilis fermentations of glucose and xylose to 2,3-BDO. The low-cost instrument displayed a lower signal-to-noise ratio than the laboratory-grade instrument, which led to comparatively lower performance overall, but still provided sufficient accuracy to monitor fermentation trends. While the ease of use of on-line monitoring systems was favored as compared to at-line systems due to the lack of sampling required and potential for automated process control, we observed some decrease in performance due to the additional complexity of the sample matrix. We have demonstrated that NIRS combined with multivariate analysis can be used for at-line and on-line monitoring of the concentrations of glucose, xylose, 2,3-BDO, acetoin, and glycerol during Z. mobilis fermentations. The decrease in signal-to-noise ratio when using a low-cost spectrometer led to greater prediction error than the laboratory-grade spectrometer for at-line monitoring. The on-line monitoring modality showed great promise for real time process control via NIRS.

09 BIOMASS FUELS↗

Calibration and Localization of Optically Pumped Magnetometers Using Electromagnetic Coils

In this paper, we propose a method to estimate the position, orientation, and gain of a magnetic field sensor using a set of (large) electromagnetic coils. We apply the method for calibrating an array of optically pumped magnetometers (OPMs) for magnetoencephalography (MEG). We first measure the magnetic fields of the coils at multiple known positions using a well-calibrated triaxial magnetometer, and model these discreetly sampled fields using vector spherical harmonics (VSH) functions. We then localize and calibrate an OPM by minimizing the sum of squared errors between the model signals and the OPM responses to the coil fields. We show that by using homogeneous and first-order gradient fields, the OPM sensor parameters (gain, position, and orientation) can be obtained from a set of linear equations with pseudo-inverses of two matrices. The currents that should be applied to the coils for approximating these low-order field components can be determined based on the VSH models. Computationally simple initial estimates of the OPM sensor parameters follow. As a first test of the method, we placed a fluxgate magnetometer at multiple positions and estimated the RMS position, orientation, and gain errors of the method to be 1.0 mm, 0.2°, and 0.8%, respectively. Lastly, we calibrated a 48-channel OPM array. The accuracy of the OPM calibration was tested by using the OPM array to localize magnetic dipoles in a phantom, which resulted in an average dipole position error of 3.3 mm. The results demonstrate the feasibility of using electromagnetic coils to calibrate and localize OPMs for MEG.

47 OTHER INSTRUMENTATION↗

Nanometer scale high-aspect-ratio trench etching at controllable angles using ballistic reactive ion etching

We demonstrate a low pressure reactive ion etching process capable of patterning nanometer scale angled sidewalls and three dimensional structures in photoresist. At low pressure the plasma has a large dark space region where the etchant ions have very large highly-directional mean free paths. Mounting the sample entirely within this dark space allows for etching at angles relative to the cathode with minimal undercutting, resulting in high-aspect ratio nanometer scale angled features. By reversing the initial angle and performing a second etch we create three-dimensional mask profiles.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Quantitative gamma-spectrometry of nuclear material under conditions of limited information about assayed objects

Canberra Industries has developed a specialized software package, Advanced In-Situ Object Counting System (A-ISOCS), which is based on absolute gamma-spectrometric measurements. It is intended for the verification of the quantity of nuclear materials under conditions where measurements are challenged by incomplete information on the properties of assayed objects which are inspected by the International Atomic Energy (IAEA)'s inspectors. A-ISOCS introduces a technique, which is called the automated optimization that allows the users to determine unknown sample parameters as well as the mass and isotopic composition of nuclear materials. The optimization process is carried out by using benchmarks referring the information included within the gamma-ray spectrum of the measured item. For each benchmark, Figure-of-Merit (FOM) is calculated and used to find the most consistent quantitative result (the best solution) corresponded to the minimized FOM. We have evaluated the capabilities and performance of A-ISOCS based on the measurements of uranium standard reference material samples, which have well-known geometry parameters and physical properties. In addition the applicability of the software to field measurements was assessed with an extensive set of gamma-ray spectra from holdup materials collected at uranium bulk handling facilities. This paper summarizes the results of our evaluation activity. (authors)

36 MATERIALS SCIENCE↗

High-Dimensional Bayesian Optimization via Semi-Supervised Learning with Optimized Unlabeled Data Sampling

We introduce a novel semi-supervised learning approach, named Teacher-Student Bayesian Optimization (TSBO ), integrating the teacher-student paradigm into BO to minimize expensive labeled data queries for the first time. TSBO incorporates a teacher model, an unlabeled data sampler, and a student model. The student is trained on unlabeled data locations generated by the sampler, with pseudo labels predicted by the teacher. The interplay between these three components implements a unique selective regularization to the teacher in the form of student feedback. This scheme enables the teacher to predict high-quality pseudo labels, enhancing the generalization of the GP surrogate model in the search space. To fully exploit TSBO , we propose two optimized unlabeled data samplers to construct effective student feedback that well aligns with the objective of Bayesian optimization. Furthermore, we quantify and leverage the uncertainty of the teacher-student model for the provision of reliable feedback to the teacher in the presence of risky pseudo-label predictions. TSBO demonstrates significantly improved sample-efficiency in several global optimization tasks under tight labeled data budgets. The implementation is available at https://github.com/reminiscenty/TSBO-Official.

Yin, Yuxuan↗

Controlled removal of hydrogen atoms from H-terminated silicon surfaces

The controlled formation of dangling bond structures on a H-terminated silicon surface is the first step in an atomically precise method of fabrication of silicon quantum electronic devices. An ultrahigh vacuum scanning tunneling microscope (STM) tip is used to selectively desorb hydrogen atoms from a Si(100)-2x1:H surface by injecting electrons with the sample held at a positive bias voltage. The authors propose a lithography method that allows the STM to operate under negative bias imaging conditions and simultaneously desorb H atoms as required. A high frequency signal is added to the negative bias voltage to deliver the required energy for hydrogen removal. The resulting current at this frequency and its harmonics are filtered to minimize their effect on the operation of the STM’s feedback control loop. The authors show that the chance of tip-sample crash during the lithography process is reduced by employing this method. They also demonstrate that this approach offers a significant potential for controlled and precise removal of H atoms from a H-terminated silicon surface and thus may be used for the fabrication of practical silicon-based atomic-scale devices.

42 ENGINEERING↗

Multi-Fidelity Stochastic Economic Dispatch for Operating Low Carbon Power Grids

Grid operators can address the inherently stochastic nature of renewables by solving a two-stage stochastic programming model that minimizes the cost of dispatch decisions while accounting for the complex grid dynamics. It is common to use a sample average approximation to estimate the expectation of the second stage costs in this model. However, the large sample count needed for numerical accuracy makes effective modeling large-scale electric grids computationally intractable. We introduce a control variate multi-fidelity estimator for the second-stage recourse that enables high quality dispatch decisions in real-time with a reduced computational burden. We obtain a hierarchy of model fidelities by linearizing the AC power flow system representation to DC power flow, and by relaxing transmission and voltage network constraints. We evaluate the performance of our proposed method on a synthetic grid with 73 buses against a deterministic baseline with persistence forecast and a high-fidelity reference. Our analysis shows a computational speed-up of 7.62x with a minimal loss in accuracy. The multi-fidelity method is well suited to fidelity combinations that use a simplified network topology in their lower fidelity model and is an attractive option for applications where accurate grid modeling needed on a limited computational budget.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Obscuration-dependent evolution of active galactic nuclei

We aim to constrain the evolution of active galactic nuclei (AGNs) as a function of obscuration using an X-ray-selected sample of ∼2000 AGNs from a multi-tiered survey including the CDFS, AEGIS-XD, COSMOS, and XMM-XXL fields. The spectra of individual X-ray sources are analyzed using a Bayesian methodology with a physically realistic model to infer the posterior distribution of the hydrogen column density and intrinsic X-ray luminosity. We develop a novel non-parametric method that allows us to robustly infer the distribution of the AGN population in X-ray luminosity, redshift, and obscuring column density, relying only on minimal smoothness assumptions. Our analysis properly incorporates uncertainties from low count spectra, photometric redshift measurements, association incompleteness, and the limited sample size. We find that obscured AGNs with N {sub H} > 10{sup 22} cm{sup –2} account for 77{sub −5}{sup +4}% of the number density and luminosity density of the accretion supermassive black hole population with L {sub X} > 10{sup 43} erg s{sup –1}, averaged over cosmic time. Compton-thick AGNs account for approximately half the number and luminosity density of the obscured population, and 38{sub −7}{sup +8}% of the total. We also find evidence that the evolution is obscuration dependent, with the strongest evolution around N {sub H} ≈ 10{sup 23} cm{sup –2}. We highlight this by measuring the obscured fraction in Compton-thin AGNs, which increases toward z ∼ 3, where it is 25% higher than the local value. In contrast, the fraction of Compton-thick AGNs is consistent with being constant at ≈35%, independent of redshift and accretion luminosity. We discuss our findings in the context of existing models and conclude that the observed evolution is, to first order, a side effect of anti-hierarchical growth.

79 ASTRONOMY AND ASTROPHYSICS↗

Estimation of Syringyl Units in Wood Lignins by FT-Raman Spectroscopy

Syringyl (S) lignin content and the syringyl-to-guaiacyl (S/G) lignin ratio are important characteristics of wood and lignocellulosic biomass. While numerous methods are available for estimating S lignin units and the S/G ratio, in this work, a new method based on Raman spectroscopy that uses the 370 cm –1 Raman band-area intensity (370-area) was developed. The reliability of the Raman method for determining S content was first tested by the quantitative analysis of three syringyl lignin models by sampling them, separately, in dioxane and in Avicel. Good linear correlations between the 370 cm –1 intensity and model concentrations were obtained. Next, the percent syringyl (%S) lignin units in various woods were measured by correlating the 370 cm –1 Raman intensity data with values of S units in lignin determined by three regularly used methods, namely, thioacidolysis, DFRC, and 2D-HSQC NMR. The former two methods take into account only the monomers cleaved from β–O–4-linked lignin units, whereas the NMR method reports S content on the whole cell wall lignin. When the 370-area intensities and %S values from the regularly used methods were correlated, good linear correlations were obtained (R 2 = 0.767, 0.731, and 0.804, respectively, for the three methods). The correlation with the highest R 2 , i.e., with the 2D NMR approach, is introduced for estimating S units in wood lignins by Raman spectroscopy as, in principle, both represent the whole cell wall lignin and not just the portion of lignin that gets cleaved to release monomers. The Raman analysis method is quick, uses minimal harmful chemicals, is carried out nondestructively, and is insensitive to the wet or dry state of the sample. The only limitations are that the sample of wood contains at least 30% S and not be significantly fluorescent, although the latter can be mitigated in some cases.

09 BIOMASS FUELS↗

First Annual Progress Report on the Procurement and Post-Irradiation Examination of the Selected Samples of Alloy 800H and Grade 92 and 91 Steels

Ferritic-martensitic steel Grade 92, with Grade 91 as a reference, together with austenitic stainless steel (or Incoloy Alloy) 800H and its grain-boundary-engineered version 800H-TMP (Thermo-Mechanical Processing), is investigated in this project. A total of fifteen Grade 92 samples from two or three heats, four T91 samples from two heats, and six 800H and six 800H-TMP samples from one heat were selected, which were primarily irradiated in the Advanced Test Reactor (ATR) of Idaho National Laboratory (INL), with the rest in the High Flux Isotope Reactor (HFIR) of Oak Ridge National Laboratory (ORNL), BOR-60 of Russia, and Phénix reactor of France. The samples were irradiated in the temperature range of 241 to 720°C and a dose range of 1.28 to ~70 displacements per atom. All the INL and ORNL samples and part of the LANL (Los Alamos National Laboratory) samples have been received at the Irradiated Materials Examination and Testing (IMET) hot cell facility. The selected ORNL samples include six Grade 92 and two 800H samples, which were irradiated in the HFIR to 0.46–14.66 dpa at 400 to ~720°C. The Grade 92 is an optimized heat and named as G92-2b. The two 800H samples have one sample as the standard solution-annealed condition and the other sample as a TMP condition with a maximized fraction of low-Σ coincidence site lattice (CSL) boundaries. Tensile test of the G92-2b samples were conducted at room temperature in the IMET hot cell. The lower temperature irradiation at 400–496.7°C to 0.52–14.66 dpa resulted in minimal changes in tensile properties. However, the higher temperature irradiation at ~683.3–720°C to 0.46–14.63 dpa tended to reduce yield and tensile strength by about –136 to –311 MPa and plastic elongation by –1 to –3% with the increasing dose. The 800H and 800H-TMP samples were tensile-tested at their irradiation temperature 580°C in the IMET hot cell, which showed >40% increase in yield and tensile strength with nearly 9% reduction in elongation for 800H-TMP compared with 800H. Three of the G92-2b samples, i.e., GB04 (7.44 dpa at ~490°C), GB05 (14.66 dpa at 496.7°C), and GB12 (14.63 dpa at ~720°C), were examined at the LAMDA for Vickers hardness measurements and microstructural characterization by SEM and TEM. Vickers hardness was successfully measured on GB12, which was reduced by is – (112.4 ± 12.3) HV1 from the control sample. However, the Vickers hardness measurements were failed on GB04 and GB05 because the samples were polished too thin to prevent the interference from the substrate (epoxy). The other half of the GB04 and GB05 will be polished for the hardness measurements, as well as nanoindentation studies. Fractography by SEM indicated increased numbers of ductile dimples (or voids) with the increasing irradiation dose, while significantly increased numbers and sizes of dimples with the increasing irradiation temperature. TEM characterization exhibited the presence of Cr 23 C 6 , VN, and Laves precipitates at boundaries and matrix, which showed pronounced precipitate-dislocation interactions (pinning effect). Dense dislocations but limited dislocation loops were observed in the samples, which noticeably reduced in GB12. Additionally, some tiny partially amorphized spherical domains were observed in GB12, which had a normal body-centered cubic lattice parameter of 9Cr steels at the surround regions but ~11% smaller than the lattice parameter of the matrix away from the amorphized spherical domains. Further characterization will be pursued to clarify the new findings.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Rapid Droplet Sampling Interface for Low-Volume, High-Throughput Mass Spectrometry Analysis

Here, we present a rapid droplet sampling interface (RDSI) electrospray ionization mass spectrometry (ESI-MS) system as a high-throughput, low-volume, noncontact, and minimal-carryover approach for characterization of liquids. Liquid characterization was achieved by combining droplet ejection with an open-face microflow capillary with a 2.5 μL/min continuous flow of carrier solvent. Through this implementation, single 0.3 nL droplets containing the analyte effectively mix with 4–8 nL of carrier solvent and create a combined electrospray plume. The carrier solvent continuously cleaned the system, eliminating carryover. A sampling rate of 5 Hz was achieved for droplets containing 1 μM propranolol or 5 μM leu-enkephalin with each droplet fully baseline-resolved (138 ± 32 ms baseline-to-baseline). Using a SCIEX API4000 mass spectrometer, a lower limit of quantification (LLOQ) of propranolol was 15 nM, corresponding to 1.16 fg of propranolol in the droplet, and was linear across 3 orders of magnitude. Further, quantitation could be achieved by adding an isotopically labeled internal standard, as done in conventional ESI. Signal transients were faster than the acquisition speed of the mass spectrometer, resulting in artificially high reproducibility of 15–30% RSD droplet-to-droplet. Analyte–solvent mixing ratios could be controlled by adjusting droplet positioning along the open-face capillary with an optimal position about 0.4 mm from the tip end. The range of analyte coverage was exemplified by measures of peptides and drugs in methanol, water, and buffer solutions. In a comparison to the Open Port Sampling Interface (OPSI) implemented on the same system, the RDSI had 78× greater sensitivity, 6× greater throughput and used significantly less carrier solvent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of gamma-sterilization on the physico-chemical properties of natural sediments

A series of experiments were completed to determine the effects of soil sterilization on various soil chemical properties including U(VI) sorption, soil pH, natural organic matter (NOM), cation exchange capacity (CEC), and iron oxidation state. Soils under investigation were a saprolitic sequence of interbedded weathered shale and limestone collected from the Oak Ridge Reservation (ORR). Sediments were sterilized by either steam sterilization at 121oC or by γ-irradiation using a cobalt-60 source. Subsamples of sediments were pretreated with dithionate-citrate-bicarbonate (DCB) and/or H2O2 to remove reducible Fe(III) oxides and NOM. Results from aerobic U(VI) sorption experiments indicated that γ-sterilized sediments sorbed more U(VI) compared to non-sterile sediments. Results from sorption experiments completed using DCB and H2O2-treated samples indicated that the iron oxide and NOM fractions of the sediment accounted for the majority of U(VI) sorption and that γ-irradiation of these phases resulted in increased sorption of U(VI). Mössbauer spectra of γ-sterilized sedimentsdisplayed a decrease in the amount of ferric iron associated with goethite and a small increase in the amount of reduced iron in silicate minerals compared to spectra from non-sterile samples. Our results suggest that sterilization by γ-irradiation induced iron reduction that may have increased sorption of U(VI) on these sediments.

54 ENVIRONMENTAL SCIENCES↗

Effects of Sterilization on the Physico-Chemical Properties of Natural Sediments From the Oak Ridge Reservation

Batch U(VI) sorption/reduction experiments were completed on sterilized and non-sterilized sediment samples to elucidate biological and geochemical reduction mechanisms. Results from X-ray absorption near-edge structure (XANES) spectroscopy revealed that {gamma}-sterilized sediments were actually better sorbents of U(VI), despite the absence of any measurable biological activity. These results indicate that {gamma}-irradiation induced significant physico-chemical changes in the sediment which is contrary to numerous other studies identifying {gamma}-sterilization as an effective and minimally invasive technique. To identify the extent and method of alteration of the soil as a result of {gamma}-sterilization, untreated soil samples, physically separated size fractions, and chemically extracted fractions of the soil were analyzed pre- and post-sterilization. The effects of sterilization on mineralogy, pH, natural organic matter (NOM), cation exchange capacity (CEC), and iron oxidation state were determined. Results indicated that major mineralogy of the clay and whole sediment samples was unchanged. Sediment pH decreased only slightly with {gamma}-irradiation; however, irradiation produced a significant decrease in CEC of the untreated sediments and affected both the organic and inorganic fractions. Moessbauer spectra of non-sterile and {gamma}-sterilized sediments measured more reduced iron present in {gamma}-sterilized sediments compared to non-sterile samples. Our results suggest that sterilization by {gamma}-irradiation induced iron reduction that may have increased the sorption and/or reduction of U(VI) onto these sediments. However, Moessbauer and batch sorption data are somewhat contradictory, the former indicates that the iron oxide or iron hydroxide minerals are more significantly reduced while the later indicates that reduced clay minerals account for greater sorption of U(VI).

54 ENVIRONMENTAL SCIENCES↗

High-throughput Fluorometric Measurement of Potential Soil Extracellular Enzyme Activities

Microbes in soils and other environments produce extracellular enzymes to depolymerize and hydrolyze organic macromolecules so that they can be assimilated for energy and nutrients. Measuring soil microbial enzyme activity is crucial in understanding soil ecosystem functional dynamics. The general concept of the fluorescence enzyme assay is that synthetic C-, N-, or P-rich substrates bound with a fluorescent dye are added to soil samples. When intact, the labeled substrates do not fluoresce. Enzyme activity is measured as the increase in fluorescence as the fluorescent dyes are cleaved from their substrates, which allows them to fluoresce. Enzyme measurements can be expressed in units of molarity or activity. To perform this assay, soil slurries are prepared by combining soil with a pH buffer. The pH buffer (typically a 50 mM sodium acetate or 50 mM Tris buffer), is chosen for the buffer's particular acid dissociation constant (pKa) to best match the soil sample pH. The soil slurries are inoculated with a nonlimiting amount of fluorescently labeled (i.e. C-, N-, or P-rich) substrate. Using soil slurries in the assay serves to minimize limitations on enzyme and substrate diffusion. Therefore, this assay controls for differences in substrate limitation, diffusion rates, and soil pH conditions; thus detecting potential enzyme activity rates as a function of the difference in enzyme concentrations (per sample). Fluorescence enzyme assays are typically more sensitive than spectrophotometric (i.e. colorimetric) assays, but can suffer from interference caused by impurities and the instability of many fluorescent compounds when exposed to light; so caution is required when handling fluorescent substrates. Likewise, this method only assesses potential enzyme activities under laboratory conditions when substrates are not limiting. Caution should be used when interpreting the data representing cross-site comparisons with differing temperatures or soil types, as in situ soil type and temperature can influence enzyme kinetics.

59 BASIC BIOLOGICAL SCIENCES↗

Uncertainties in Air Exchange using Continuous-Injection, Long-Term Sampling Tracer-Gas Methods

The PerFluorocarbon Tracer (PFT) method is a low-cost approach commonly used for measuring air exchange in buildings using tracer gases. It is a specific application of the more general Continuous-Injection, Long-Term Sampling (CILTS) method. The technique is widely used but there has been little work on understanding the uncertainties (both precision and bias) associated with its use, particularly given that it is typically deployed by untrained or lightly trained people to minimize experimental costs. In this article we will conduct a first-principles error analysis to estimate the uncertainties and then compare that analysis to CILTS measurements that were over-sampled, through the use of multiple tracers and emitter and sampler distribution patterns, in three houses. We find that the CILTS method can have an overall uncertainty of 10-15percent in ideal circumstances, but that even in highly controlled field experiments done by trained experimenters expected uncertainties are about 20percent. In addition, there are many field conditions (such as open windows) where CILTS is not likely to provide any quantitative data. Even avoiding the worst situations of assumption violations CILTS should be considered as having a something like a ?factor of two? uncertainty for the broad field trials that it is typically used in. We provide guidance on how to deploy CILTS and design the experiment to minimize uncertainties.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of an Ion Mobility Spectrometry-Orbitrap Mass Spectrometer Platform

Complex samples benefit from multidimensional measurements where higher resolution enables more complete characterization of biological and environmental systems. To address this challenge, we developed a drift tube-based ion mobility spectrometry-Orbitrap mass spectrometer (IMS-Orbitrap MS) platform. To circumvent the time scale disparity between the fast IMS separation and the much slower Orbitrap MS acquisition, we utilized a dual gate and pseudorandom sequences to multiplexed injection of ions and allowing operation in signal averaging (SA), single multiplexing (SM) and double multiplexing (DM) IMS modes to optimize the signal-to-noise ratio of the measurements. For the SM measurements, a previously developed algorithm was used to reconstruct the IMS data. A new algorithm was developed for the DM analyses involving a two-step process that first recovers the SM data and then decodes the SM data. The algorithm also performs multiple refining procedures in order to minimize demultiplexing artifacts. The new IMS-Orbitrap MS platform was demonstrated by the analysis of proteomic and petroleum samples, where the integration of IMS and high mass resolution proved essential for accurate assignment of molecular formulae.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stochastic average model methods

We consider the solution of finite-sum minimization problems, such as those appearing in nonlinear least-squares or general empirical risk minimization problems. We are motivated by problems in which the summand functions are computationally expensive and evaluating all summands on every iteration of an optimization method may be undesirable. Here we present the idea of stochastic average model (SAM) methods, inspired by stochastic average gradient methods. SAM methods sample component functions on each iteration of a trust-region method according to a discrete probability distribution on component functions; the distribution is designed to minimize an upper bound on the variance of the resulting stochastic model. We present promising numerical results concerning an implemented variant extending the derivative-free model-based trust-region solver POUNDERS, which we name SAM-POUNDERS.

97 MATHEMATICS AND COMPUTING↗