Search NASA⌕ Search

SEARCH · Search NASA

Results for “side load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Avoiding Braess' Paradox Through Collective Intelligence

In an Ideal Shortest Path Algorithm (ISPA), at each moment each router in a network sends all of its traffic down the path that will incur the lowest cost to that traffic. In the limit of an infinitesimally small amount of traffic for a particular router, its routing that traffic via an ISPA is optimal, as far as cost incurred by that traffic is concerned. We demonstrate though that in many cases, due to the side-effects of one router's actions on another routers performance, having routers use ISPA's is suboptimal as far as global aggregate cost is concerned, even when only used to route infinitesimally small amounts of traffic. As a particular example of this we present an instance of Braess' paradox for ISPA'S, in which adding new links to a network decreases overall throughput. We also demonstrate that load-balancing, in which the routing decisions are made to optimize the global cost incurred by all traffic currently being routed, is suboptimal as far as global cost averaged across time is concerned. This is also due to "side-effects", in this case of current routing decision on future traffic. The theory of COllective INtelligence (COIN) is concerned precisely with the issue of avoiding such deleterious side-effects. We present key concepts from that theory and use them to derive an idealized algorithm whose performance is better than that of the ISPA, even in the infinitesimal limit. We present experiments verifying this, and also showing that a machine-learning-based version of this COIN algorithm in which costs are only imprecisely estimated (a version potentially applicable in the real world) also outperforms the ISPA, despite having access to less information than does the ISPA. In particular, this COIN algorithm avoids Braess' paradox.

Wolpert , David H.↗

MPEX High Heat Flux Plasma Dump Design, Manufacture, and Articles Test

Here, the Material Plasma Exposure eXperiment (MPEX) device is a steady-state linear plasma device currently in the final design phase at the Oak Ridge National Laboratory. This device will reach ion fluences up to 10 31 m -2 and will be used to expose neutron-irradiated materials to divertor-relevant plasmas and to study the effects of plasma-material interactions. These studies will elucidate the complex effects of plasmas with divertor candidate materials capable of withstanding high heat flux and high fluences for next-generation fusion devices. Bidirectional plasma will be generated using a high-power (200 kW) helicon source. Plasma will be confined by superconducting magnets. The last plasma-facing component on the upstream side of the MPEX device is the dump, which has been designed to intercept plasma and energetic particles. The dump will have a total heat load of 9.2 kW. A copper alloy (Glidcop AL-15) was selected for use in the water-cooled flange design because of its high thermal conductivity, its retaining strength at elevated temperatures, and its ability to be used in the high-temperature braze joints used in this application. Titanium-zirconium-molybdenum (TZM) tiles are brazed to the Glidcop AL-15 flange using high-temperature braze alloy. External water-cooling channels are used on the dump flange to prevent water leakage inside the vacuum space. This article discusses the details of the high heat flux dump design, including the computational fluid dynamics (CFD) and structural analyses performed to validate the design to meet the operational requirements of the MPEX device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modelling a rotating shaft as an elastically restrained Bernoulli-Euler beam

Industrial rotating machines may be exposed to severe dynamic excitations due to resonant working regimes. Dealing with the bending vibration, problem of a machine rotor, the shaft—and attached discs—can be simply modelled using the Bernoulli-Euler beam theory, as a continuous beam subjected to a specific set of boundary conditions. In this study, the authors recall Rayleigh’s method to propose an iterative strategy, which allows for the determination of natural frequencies and mode shapes of continuous beams taking into account the effect of attached concentrated masses and rotational inertias, including different stiffness coefficients at the right and the left end sides. The algorithm starts with the exact solutions from Bernoulli-Euler’s beam theory, which are then updated through Rayleigh’s quotient parameters. Several loading cases are examined in comparison with the experimental data and examples are presented to illustrate the validity of the model and the accuracy of the obtained values.

42 ENGINEERING↗

AGGREGATE: dAta-driven modelinG preservinG contRollable dEr for outaGe mAnagemenT and rEsiliency (Final Report)

The AGGREGATE project team successfully developed and validated various modules for outage management. Brief summaries of each module are provided to showcase their strength for outage management and restoration for a distribution system with a high penetration of connected distribution energy resources (DERs). In recent years, inverter-based DERs have been widely deployed in distribution system. A most of behind-the-meter (BTM) solar power generation is not visible to the utility. The data-driven DER and load estimation modules are using machine learning (ML) and artificial intelligence (AI) to manage this issue, which provides an opportunity for distribution system operators (DSOs) to operate systems and make decisions in real-time for a distribution system with a high penetration of DERs deployed. Also, the estimated DER and true load can be further leveraged in network aggregation and cold-load pick up estimation for reducing the computing complexity and providing for fast restoration. After load demand and DER power generations have been estimated, the information will support topology and state estimation (SE). The topology estimation module demonstrated the viability of mixed integer linear programming (MILP) formulation to estimate the most likely operational radial topology and outage sections using power flow measurements, historical/estimated load and DERs data and smart meter ping measurements. Formulation includes continuous (power flow, load and DERs data) and binary measurements (smart meter ping measurements) in a single formulation. Errors in continuous data and binary data are modeled as normal distribution and Bernoulli distribution, respectively. In the future distribution grid, the power injection from controllable DERs will be essential for efficient and resilient grid operation. However, determining the optimal DER injections and restoration actions is dependent on knowledge of the system states. State estimation (SE), already the cornerstone of transmission energy management systems, will become commonplace in distribution management systems as more measurements become available from deployment of automated metering infrastructure (AMI). Observability analysis is the first step in SE, as it determines the sufficiency of the available measurements for accurately estimating the current system states. A new type of pseudo-measurement called a Correlational Measurement (CM) is introduced in this module, to enhance the observability of the system to enable more accurate SE. CMs encapsulate knowledge of correlation between demand patterns for similar classes of loads as well as injection patterns for same-technology renewable DERs. During grid contingency scenarios, DERs have been traditionally disconnected, without any fault ride-through capabilities. However, with new regulations and better technology, it is feasible for these resources to contribute to the grid’s restoration after an adverse event and hence enhance resilience. The controllability module proposes a two-step restoration scheme for the power system restoration process by leveraging additional degrees of freedom in power electronics interfaced DERs for mitigating voltage problems. In a resilience mode without the utility system, the distribution grid relies on DERs to serve critical load. In such a severe event with multiple faults on the distribution feeders, actuation of various protective devices (PDs) divides the distribution system into electrical islands. The undetected actuated PDs due to fault current contributions from DERs can delay the restoration process, thereby reducing the system resilience. The Advanced Outage Management (AOM) and the Advanced Feeder Restoration (AFR) modules developed in this project provide improved system resilience with multiple DERs. AOM identifies the faulted sections and actuated PDs in a distribution system with DERs by incorporating smart meter data. The most credible outage scenario including fault locations, PD actuations, and fault indicator (FI) failures is identified by a set of binary integer linear programming incorporating hypotheses. The AFR module serves to restore a distribution system with available energy resources taking into consideration the availability of utility sources and DERs. By partitioning the system into islands, critical load will be served with the available generation resources within islands based on the solution of a MILP. When the utility systems become available, the optimal path will be determined by a spanning tree search algorithm that reconnects these islands back to substations and restores the remaining load. The transmission and distribution (T&D) co-simulation module was used to validate the effect of a control action performed on the distribution side assets as it propagates to the transmission side. This ensures that the control action performed results in a feasible operating point on both the transmission and the distribution system. In addition to validation, the team used the T&D co-simulation module to demonstrate how distribution system assets can be used to mitigate issues on the transmission system. Specifically, the team demonstrated that appropriate switching operations on the distribution side can alleviate the line overload condition on the transmission side without causing new operational constraint violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Prediction of unsteady aerodynamic loadings caused by trailing edge control surface motions in subsonic compressible flow: Computer program description

A digital computer program has been developed to calculate unsteady loadings caused by motions of lifting surfaces with trailing edge control based on the subsonic kernal function approach. The pressure singularities at hinge line and side edges have been extracted analytically as a preliminary step to solving the integral by collocation. The program calculates generalized aerodynamic forces for user supplied deflection modes. Optional intermediate output includes pressure at an array of points, and sectional generalized forces. From one to four controls on the half span can be accommodated.

Redman, M. C.↗

Computation of supersonic laminar viscous flow past a pointed cone at angle of attack in spinning and coning motion

Computational results obtained with a parabolic Navier-Stokes marching code are presented for supersonic viscous flow past a pointed cone at angle of attack undergoing a combined spinning and coning motion. The code takes into account the asymmetries in the flow field resulting from the motion and computes the asymmetric shock shape, crossflow and streamwise shear, heat transfer, crossflow separation and vortex structure. The side force and moment are also computed. Reasonably good agreement is obtained with the side force measurements of Schiff and Tobak. Comparison is also made with the only available numerical inviscid analysis. It is found that the asymmetric pressure loads due to coning motion are much larger than all other viscous forces due to spin and coning, making viscous forces negligible in the combined motion.

Agarwal, R.↗

Supersonic Laminar Viscous Flow Past a Cone at Angle of Attack in Spinning and Coning Motion

Computational results obtained with a parabolic Navier-Stokes marching code are presented for supersonic viscous flow past a pointed cone at angle of attack undergoing a combined spinning and coning motion. The code takes into account the asymmetries in the flowfield resulting from the motion and computes the asymmetric shock shape, crossflow and streamwise shear, heat transfer, crossflow separation and vortex structure. The side force and moment are also computed. Reasonably good agreement is obtained with the side force measurements of Schiff and Tobak. Comparison is also made with the only available numerical inviscid analysis. It is found that the asymmetric pressure loads due lo coning motion are much larger than all other viscous forces due lo spin and coning, making viscous forces negligible in the combined motion.

Agarwal, Ramesh↗

Scintillator based fiber optic plate for neutron imaging applications and the like

A chalcopyrite, colquiriite, neutron absorber loaded glass, or plastic scintillator based fiber optic plate for use in a neutron imaging system, including: a plurality of optical fiber segments disposed side-by-side adjacent to one another in a parallel array; and a binder material disposed between and coupling the plurality of optical fiber segments together. A diffuse reflective material is optically coupled to the plurality of first ends of the plurality of optical fiber segments. An optical detector device is optically coupled to the plurality of second ends of the plurality of optical fiber segments opposite the diffuse reflective material. Optionally, the fiber optic plate further includes a diffuse reflective material disposed one or more of on an exterior surface of each of the plurality of optical fiber segments and between the plurality of optical fiber segments.

42 ENGINEERING↗

THERMAL STRUCTURAL AND SHOCK EVENT EVALUATIONS OF THE FUELING PELLET INJECTION SYSTEM FOR ITER

The US is among seven partner nations in a collaborative effort to design, build, and demonstrate fusion’s ability to be a large-scale carbon free energy source. Each country has its own Domestic Agencies (DA) that contribute directly to the ITER project. US ITER, which is a DOE Office of Science project managed by Oak Ridge National Laboratory, is developing world class engineering solutions to the design, construction, and assembly of the burning plasma experiment that can demonstrate the scientific and technological feasibility of fusion. US ITER’s scope includes completing the preliminary and final design, qualifying materials and processes for manufacture and testing, executing manufacturing, and delivering the Fueling Pellet Injection System (FPIS) to the ITER site for assembly. The US-ITER FPIS system is designed to inject cryogenically frozen pellets of deuterium-tritium (D-T) into the plasma. The FPIS has two main functions: 1. Provide a steady supply of deuterium and tritium fuel, 2. Mitigating the impact of edge localized modes on the plasma facing components. The FPIS will have the capability to reside in three port cells within a tritium second barrier containment cask. Each pellet cask contains three flight tubes linking with penetrations on the torus cryopump housing and vacuum vessel (VV): two for the magnetic high field side (HFS) pellet injection and one for the magnetic low field side (LFS) pellet injection. This paper presents results of the thermal-structural analyses of the FPIS flight tube structural components when subjected to various loads such as electromagnetic (EM) loads, nuclear heating, seismic, and operational, and dynamic shock events. The resulting temperatures and stresses under combined conditions have been found to satisfy the design criteria to ensure safe and reliable operation of the FPIS flight tubes within the vacuum vessel.

Martinez, Oscar↗

Detailed Fission Power 2D-Mapping of AFIP-2 Experiment in ATR CFT Position

The NNSA (National Nuclear Security Administration) RERTR (Reduced Enrichment for Research and Test Reactors) program assigned INL (Idaho National Laboratory) the responsibility of developing and demonstrating high uranium density research reactor fuel forms to enable the use of low enriched uranium (LEU) in the research reactors around the world. A series of full-size fuel plate irradiation tests are proposed for the ATR (Advanced Test Reactor). Labeled the AFIP (ATR Full-size-plates In center flux trap Position) experiments, these tests will be conducted in the ATR center flux trap. The AFIP-2 experiment will contain two full size fuel plates fabricated at the Oak Ridge National Laboratory-Y-12 (ORNL). The nominal fuel zone is rectangular in shape having a designed length of 21.5-in (54.6l-cm), width of 1.6-in (4.064-cm), and uniform thickness of 0.014-in (0.03556-cm). This gives a nominal fuel zone volume of 0.482 in3 (7.89 cm3) in each fuel plate. The test holder accommodates two independent test trains. Each test train is designed to hold 2 plates, for a total of 4 plates per test holder. AFIP-2 test plates will be irradiated at a peak surface heat flux of about 350 W/cm2 and discharged at a peak U-235 burn-up of about 70 at.%. Based on limited irradiation testing of the monolithic (U10Mo) fuel form, it is desirable to keep the peak fuel temperature below 250°C; to achieve this, it will be necessary to keep plate heat fluxes below 500 W/cm2. Due to the heavy U-235 loading and width of 1.6-in (4.064 cm), the neutron self-shielding will increase the local-to-average-ratio fission power near the sides of the fuel plates. To assure the AFIP-2 experiment will comply with the ATR safety requirements, a very detailed 2 dimensional (2D) Y-Z fission power profile was evaluated to best predict the fuel plate temperature distribution. The ability to accurately predict fuel plate power and burnup are essential in the AFIP-2 fuel test train design and the irradiated fuel performance evaluation. We obtained the required power and heat generation rates within test train for the thermal analyses. A detailed MCNP Y-Z mini-plate fuel model was developed. The Y-Z model divides each fuel mini-plate into 30 equal intervals in Y and Z directions. The MCNP-calculated results and the detailed Y-Z fission power mapping were used to help design the AFIP-2 fuel test assembly to ensure that the capsule thermal-hydraulic limits will not exceed the ATR safety limit.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Submodule-Level Decentralized Control for Cascaded Quadruple Active Bridge-Based Medium-Voltage Converters: Preprint

High-power, low-voltage DC (LVDC) loads, such as AI data centers, electric vehicle fast-charging hubs, and hydrogen electrolyzers, are accelerating the deployment of solid-state transformers (SSTs) that directly interface medium-voltage AC (MVAC) to LVDC, streamlining power delivery. This paper proposes a submodule-level decentralized control strategy for an SST comprising a cascaded H-bridge (CHB) active rectifier on the MVAC side and per-module quadruple-active-bridge (QAB) converters on the LVDC side with local controllers. The proposed strategy eliminates the need for high-fidelity, real-time cross-isolation communication by synchronizing all active bridges to a common heartbeat signal and enabling the primary- and secondary-side controllers to generate independent local control signals (phase shifts). The resultant phase shifts naturally govern average and double-line frequency power transfer between active bridges, enabling each side to meet its control objectives using only local measurements. Detailed controller design considerations are presented based on a stability analysis. Comprehensive electromagnetic-transient simulations demonstrate tight DC-link voltage regulation, high-quality grid currents, and robust operation under load transients and grid disturbances, without real-time communication among the submodule controllers. These results indicate that the proposed scheme can significantly enhance the reliability, scalability, and flexibility of cascaded bridge-based medium-voltage converters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrolyzers Enhancing Flexibility in Electric Grids

This paper presents a real-time simulation with hardware-in-the-loop (HIL) based approach for verifying the performance of electrolyzer systems in providing grid support. Hydrogen refueling stations premdominantly use electrolyzer systems to generate hydrogen, and are proposed to have the potential of becoming smarter loads which can pro-actively provide grid services. Based on experimental findings electrolyzer systems are observed to have a high level of controllability and hence can add flexibility to the grid from demand side. Greater awareness and controllability is proposed, developed, implemented, and tested by a 'frond end controller' in real-time environment. It can optimize the operation of electrolyzer systems based on the information collected by a communication module. Real-time tests are performed to verify the performance of front end controller driven electrolyzers to provide grid support that enables greater economic revenue and grid support for hydrogen producers under dynamic conditions. The front end controller proposed in this paper is tested with electrolyzers, however it is proposed as a generic control topology that is applicable to any load.

08 HYDROGEN↗

Influence of shockwave profile on ejection of micron-scale material from shocked Sn surfaces: an experimental study

This effort experimentally investigates the relationship between shock-breakout pressure and the amount of micron-scale fragments ejected (ejecta) upon shock release at the metal/vacuum interface of Sn targets shocked with a supported shockwave. The results are compared with an analogous set derived from HE shocked Sn targets, Taylor shockwave loading. The supported shock-pulse was created by impacting a Sn target with a Ti64 (Ti-6Al-4V) impactor that was accelerated using a powder gun. Ejecta production at the free-surface or back-side of the Sn targets were characterized through use of piezoelectric pins and Asay foils, and heterodyne velocimetry verified the time of shock release and the breakout pressure.

66↗

Field Study of Performance, Comfort, and Sizing of Two Variable-Speed Heat Pumps Installed in a Single 2-Story Residence

With the recent advancements in the application of variable-speed (VS) compressors to residential HVAC systems, opportunities are now available to size heat pumps (HPs) to more effectively meet heating and cooling loads in many of the climate zones in the US with limited use of inefficient resistance heat. This is in contrast to sizing guidance for traditional single-speed HPs that limits the ability to oversize with regard to cooling loads, because of risks of poor dehumidification during the cooling season and increased cycling losses. VS-drive HPs can often run at 30-40% of their rated cooling capacity to reduce cycling losses, and can adjust fan speed to provide better indoor humidity control. Detailed air-side performance data was collected on two VS-drive heat pumps installed in a single unoccupied research house in Knoxville, TN, a mixed-humid climate. One system provided space conditioning for the upstairs, while the other unit provided space conditioning for the downstairs. Occupancy was simulated by operating the lights, shower, appliances, other plug loads, etc. to simulate the sensible and latent loads imposed on the building space by internal electric loads and human occupants according to the Building America Research Benchmark (2008). The seasonal efficiency and energy use of the units are calculated. Annual energy use is compared to that of the single speed minimum efficiency HPs tested in the same house previously. Sizing of the units relative to the measured building load and manual J design load calculations is examined. The impact of the unit sizing with regards to indoor comfort is also evaluated.

Munk, Jeffrey D↗

AC Power Flow Based DLMP Calculation and Decomposition Method to Smooth Power Fluctuation of Distributed Renewable Energy Sources

As the penetration of renewable energy sources increases, the growing renewable power variability brings ramping issues to power systems. Meanwhile, the development of distributed energy resources (DERs) makes the distribution systems to provide both energy and ancillary services. To incentivise individual resources and customers to alleviate ramping issues on the demand side, a two-stage distribution locational marginal price (DLMP) calculation and decomposition method is developed to formulate the marginal power ramping price for DERs. In the first stage of the proposed method, a distribution system operator market scheduling model based on AC optimal power flow is designed to estimate the optimal operating point of the distribution system. Subsequently, the voltage and power flow constraints are linearised in stage two to calculate DLMP. Finally, based on the Lagrange function and sensitivity factors, DLMP is decomposed to the marginal costs for active/reactive power, voltage management, power loss and power variability. Case studies demonstrate that the proposed model can effectively smooth the power fluctuation and reduce the ramping flexibility requirements of distribution systems.

AC optimal power flow↗

Evaluation of flow and heat transfer inside lean pre-mixed combustor systems under reacting flow conditions

The objective of the present work was to develop methodologies to measure heat transfer within a reacting gas turbine combustor. To accomplish this, an optically accessible research combustor system was designed and constructed at Virginia Tech, capable of operating at 650 K inlet temperature, maximum air mass flow rates of 1.3 kg/s, and flame temperatures over 1800 K. Flow and heat transfer measurements at non-reacting and reacting conditions were carried out for Reynolds numbers (Re) with respect to the combustor diameter ranging from ~11 500 to ~140 000 (depending on the condition). Particle Image Velocimetry (PIV) was used to measure the non-reacting flow field within the burner, leading to the identification of coherent structures in the flow that accounted for over 30% of the flow fluctuation kinetic energy along the swirling jet shear layers. The capability of infrared (IR) thermography to image surface temperatures through a fused silica (quartz) glass was demonstrated at non-reacting conditions. IR thermography was then used to measure the non-reacting steady state heat transfer along the combustor liner. A peak in heat transfer was identified at ~1 nozzle diameter downstream of the combustor dome plate. The peak Nusselt number along the liner was over 18 times higher than that predicted from fully developed turbulent pipe flow correlations, which have traditionally been used to estimate flame side combustor heat transfer. For the reacting measurements, a novel time-dependent heat transfer methodology was developed that allowed for the investigation of transient heat loads, including those occurring during engine ignition and shutdown. The methodology was validated at non-reacting conditions, by comparing results from an experiment with changing flow temperature, to the results obtained at steady state. The difference between the time-dependent and the steady state measurements were between 3% and 17.3% for different mass flow conditions. The time-dependent methodology was applied to reacting conditions for combustor Reynolds numbers of ~12 000 and ~24 000. At an equivalence ratio of ~0.5 and a combustor Reynolds number of ~12 000, the peak heat load location in reaction was shifted downstream by 0.2 nozzle diameters compared to the non-reacting cases. At higher equivalence ratios, and more visibly at a Reynolds number of ~24 000, the heat transfer distribution along the combustor liner exhibited two peaks, upstream and downstream of the impingement location (X/DN = 0.8-1.0 and X/DN ≈ 2.5). Reacting PIV was performed at Re = 12 000 showing the presence of a strong corner recirculation, which could potentially convect reactants upstream of the impingement point, leading to the double peak structure observed. The methodologies developed have provided insight into heat transfer within gas turbine combustors. The methods can be used to explore additional conditions and expand the dataset beyond what is presented, to fully characterize reacting combustor heat transfer.

42 ENGINEERING↗