Search NASA⌕ Search

SEARCH · Search NASA

Results for “software based”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Modeling performance of data collection systems for high-energy physics

Exponential increases in scientific experimental data are outpacing silicon technology progress, necessitating heterogeneous computing systems—particularly those utilizing machine learning (ML)—to meet future scientific computing demands. The growing importance and complexity of heterogeneous computing systems require systematic modeling to understand and predict the effective roles for ML. We present a model that addresses this need by framing the key aspects of data collection pipelines and constraints and combining them with the important vectors of technology that shape alternatives, computing metrics that allow complex alternatives to be compared. For instance, a data collection pipeline may be characterized by parameters such as sensor sampling rates and the overall relevancy of retrieved samples. Alternatives to this pipeline are enabled by development vectors including ML, parallelization, advancing CMOS, and neuromorphic computing. By calculating metrics for each alternative such as overall F1 score, power, hardware cost, and energy expended per relevant sample, our model allows alternative data collection systems to be rigorously compared. We apply this model to the Compact Muon Solenoid experiment and its planned high luminosity-large hadron collider upgrade, evaluating novel technologies for the data acquisition system (DAQ), including ML-based filtering and parallelized software. The results demonstrate that improvements to early DAQ stages significantly reduce resources required later, with a power reduction of 60% and increased relevant data retrieval per unit power (from 0.065 to 0.31 samples/kJ). However, we predict that further advances will be required in order to meet overall power and cost constraints for the DAQ.

Olin-Ammentorp, Wilkie (ORCID:0000000224729862)↗

Serpent and MCNP Calculations of the Energy Deposition in the Transformational Challenge Reactor

This paper focuses on the calculation of the energy deposition in the Transformational Challenge Reactor by two major Monte Carlo codes: Serpent and MCNP. The first software computation relies on Kinetic Energy Released per unit Mass (KERMA) factors while the second one relies on Q-values. The results from these two independent computation methodologies are in very good agreement; however, Serpent runs much faster than MCNP (for the same computational model) and allows for a detailed energy deposition distribution from a 1-mm-side square mesh with a relative statistical error between 0.5% and 1%. This detailed energy deposition is suitable for multiphysics analyses aimed at design optimizations. In order to calculate the energy deposition, Serpent needs enhanced ACE files (distributed by the software developers). Unlike other Monte Carlo software that uses inputs based on Python or Java languages, the Serpent input syntax is very similar to that of MCNP; a Python script can convert a MCNP input to a Serpent input in seconds. For simulations not requiring the calculation of the energy deposition, Serpent can also read nuclear data from MCNP ACE files, which eventually improves the comparison of the results of the two codes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

NeedATool: A NEEDLET ANALYSIS TOOL FOR COSMOLOGICAL DATA PROCESSING

We introduce NeedATool (Needlet Analysis Tool), a software for data analysis based on needlets, a wavelet rendition which is powerful for the analysis of fields defined on a sphere. Needlets have been applied successfully to the treatment of astrophysical and cosmological observations, and in particular to the analysis of cosmic microwave background (CMB) data. Usually, such analyses are performed in real space as well as in its dual domain, the harmonic one. Both spaces have advantages and disadvantages: for example, in pixel space it is easier to deal with partial sky coverage and experimental noise; in the harmonic domain, beam treatment and comparison with theoretical predictions are more effective. During the last decade, however, wavelets have emerged as a useful tool for CMB data analysis, since they allow us to combine most of the advantages of the two spaces, one of the main reasons being their sharp localization. In this paper, we outline the analytical properties of needlets and discuss the main features of the numerical code, which should be a valuable addition to the CMB analyst's toolbox.

79 ASTRONOMY AND ASTROPHYSICS↗

Arecibo pulsar survey using ALFA. IV. Mock spectrometer data analysis, survey sensitivity, and the discovery of 40 pulsars

The on-going Arecibo Pulsar-ALFA (PALFA) survey began in 2004 and is searching for radio pulsars in the Galactic plane at 1.4 GHz. Here we present a comprehensive description of one of its main data reduction pipelines that is based on the PRESTO software and includes new interference-excision algorithms and candidate selection heuristics. This pipeline has been used to discover 40 pulsars, bringing the survey’s discovery total to 144 pulsars. Of the new discoveries, eight are millisecond pulsars (MSPs; P<10 ms) and one is a Fast Radio Burst (FRB). This pipeline has also re-detected 188 previously known pulsars, 60 of them previously discovered by the other PALFA pipelines. We present a novel method for determining the survey sensitivity that accurately takes into account the effects of interference and red noise: we inject synthetic pulsar signals with various parameters into real survey observations and then attempt to recover them with our pipeline. We find that the PALFA survey achieves the sensitivity to MSPs predicted by theoretical models but suffers a degradation for P≳100 ms that gradually becomes up to ∼10 times worse for P>4 s at DM<150 pc cm{sup −3}. We estimate 33 ± 3% of the slower pulsars are missed, largely due to red noise. A population synthesis analysis using the sensitivity limits we measured suggests the PALFA survey should have found 224 ± 16 un-recycled pulsars in the data set analyzed, in agreement with the 241 actually detected. The reduced sensitivity could have implications on estimates of the number of long-period pulsars in the Galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

CASSIS: THE CORNELL ATLAS OF SPITZER/INFRARED SPECTROGRAPH SOURCES

We present the spectral atlas of sources observed in low resolution with the Infrared Spectrograph on board the Spitzer Space Telescope. More than 11,000 distinct sources were extracted using a dedicated algorithm based on the SMART software with an optimal extraction (AdOpt package). These correspond to all 13,000 low-resolution observations of fixed objects (both single source and cluster observations). The pipeline includes image cleaning, individual exposure combination, and background subtraction. Particular attention is given to bad pixel and outlier rejection at the image and spectra levels. Most sources are spatially unresolved so that optimal extraction reaches the highest possible signal-to-noise ratio. For all sources, an alternative extraction is also provided that accounts for all of the source flux within the aperture. CASSIS provides publishable quality spectra through an online database together with several important diagnostics, such as the source spatial extent and a quantitative measure of detection level. Ancillary data such as available spectroscopic redshifts are also provided. The database interface will eventually provide various ways to interact with the spectra, such as on-the-fly measurements of spectral features or comparisons among spectra.

79 ASTRONOMY AND ASTROPHYSICS↗

The evolution of contact prediction: Evidence that contact selection in statistical contact prediction is changing

Over the last few years, the field of protein structure prediction has been transformed by increasingly-accurate contact prediction software. These methods are based on the detection of coevolutionary relationships between residues from multiple sequence alignments. However, despite speculation, there is little evidence of a link between contact prediction and the physico-chemical interactions which drive amino-acid coevolution. Furthermore, existing protocols predict only a fraction of all protein contacts and it is not clear why some contacts are favoured over others. Using a dataset of 863 protein domains, we assessed the physico-chemical interactions of contacts predicted by CCMpred, MetaPSICOV, and DNCON2, as examples of direct coupling analysis, meta-prediction, and deep learning. We considered correctly-predicted contacts and compared their properties against the protein contacts that were not predicted. Predicted contacts tend to form more bonds than non-predicted contacts, which suggests these contacts may be more important than contacts that were not predicted. Comparing the contacts predicted by each method, we found that metaPSICOV and DNCON2 favour accuracy whereas CCMPred detects contacts with more bonds. This suggests that the push for higher accuracy may lead to a loss of physico-chemically important contacts. These results underscore the connection between protein physico-chemistry and the coevolutionary couplings that can be derived from multiple sequence alignments. This relationship is likely to be relevant to protein structure prediction and functional analysis of protein structure and may be key to understanding their utility for different problems in structural biology. We use publicly-available databases. Our code is available for download at http://opig.stats.ox.ac.uk/.

59 BASIC BIOLOGICAL SCIENCES↗

Fitting dynamical x-ray diffraction data over the World Wide Web.

The first implementation of fitting X-ray Bragg diffraction profiles from strained multilayer crystals at a remote web-based X-ray software server is presented. The algorithms and the software solutions involved in the process are described. The suggested technology can be applied to a wide range of scientific research and has the potential to promote remote collaborations across scientific communities.

99 GENERAL AND MISCELLANEOUS↗

Dragonfly : an implementation of the expand–maximize–compress algorithm for single-particle imaging

Single-particle imaging (SPI) with X-ray free-electron lasers has the potential to change fundamentally how biomacromolecules are imaged. The structure would be derived from millions of diffraction patterns, each from a different copy of the macromolecule before it is torn apart by radiation damage. The challenges posed by the resultant data stream are staggering: millions of incomplete, noisy and un-oriented patterns have to be computationally assembled into a three-dimensional intensity map and then phase reconstructed. In this paper, the Dragonfly software package is described, based on a parallel implementation of the expand–maximize–compress reconstruction algorithm that is well suited for this task. Auxiliary modules to simulate SPI data streams are also included to assess the feasibility of proposed SPI experiments at the Linac Coherent Light Source, Stanford, California, USA.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of geometrical factors for quantitative angle-resolved photoelectron spectroscopy

For conventional angle-resolved x-ray photoelectron spectroscopy (ARXPS), the area under the core-level peaks depends mainly on the in-depth distribution of chemical species at the top surface of a specimen. But the x-ray photoelectron spectroscopy (XPS) intensity is also affected by tool-related geometrical factors such as the shape of the x-ray beam, the spectrometer analysis volume, and the manipulator rotation axis. Data analysis is therefore typically based on normalization with respect to the signal from the substrate. Here, we present an original method to perform quantitative ARXPS without normalization, involving evaluation of these geometrical factors. The method is illustrated for a multiprobe XPS system using a methodology based on a specific software (XPSGeometry{sup Registered-Sign }), but is a general process that can be adapted to all types of XPS equipment, even those not specifically designed for ARXPS. In that case, this method enables bringing the sample as close as possible to the manipulator axis of rotation in order to perform automatic acquisitions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Numerical Simulations of Cathodoluminescence Measurements in Thin-Film Solar Cells

Cathodoluminescence (CL) measurements can be applied to assess grain-boundary (GB) and grain-interior (GI) recombination in thin-film solar cell materials and made quantitative if we can develop CL models that account for material and measurement complexities. Recently, we developed a three-dimensional numerical CL model, based in MATLAB, that simulates the GI CL intensity as a function of four parameters: grain size, GI lifetime, and GB and surface recombination velocities. The model assumes that GB electrostatic potentials are screened by the high excesscarrier densities used in the CL measurement such that transport is governed by ambipolar diffusion. Here, we develop models to address directly GB potentials and their effects on these measurements. First, we transfer the MATLAB-based model to COMSOL software, and then introduce shallow donors to the GBs to produce potentials. We also develop a two-dimensional model in COMSOL to simulate CL GB contrast with GB potentials. Simulations indicate that GB potentials can increase or decrease CL intensities relative to the zero-potential case. However, the high electron-beam currents typically applied in CL measurements minimize the impact of GB potentials.

14 SOLAR ENERGY↗

An approach to using conventional brachytherapy software for clinical treatment planning of complex, Monte Carlo-based brachytherapy dose distributions

Certain brachytherapy dose distributions, such as those for LDR prostate implants, are readily modeled by treatment planning systems (TPS) that use the superposition principle of individual seed dose distributions to calculate the total dose distribution. However, dose distributions for brachytherapy treatments using high-Z shields or having significant material heterogeneities are not currently well modeled using conventional TPS. The purpose of this study is to establish a new treatment planning technique (Tufts technique) that could be applied in some clinical situations where the conventional approach is not acceptable and dose distributions present cylindrical symmetry. Dose distributions from complex brachytherapy source configurations determined with Monte Carlo methods were used as input data. These source distributions included the 2 and 3 cm diameter Valencia skin applicators from Nucletron, 4-8 cm diameter AccuBoost peripheral breast brachytherapy applicators from Advanced Radiation Therapy, and a 16 mm COMS-based eye plaque using {sup 103}Pd, {sup 125}I, and {sup 131}Cs seeds. Radial dose functions and 2D anisotropy functions were obtained by positioning the coordinate system origin along the dose distribution cylindrical axis of symmetry. Origin:tissue distance and active length were chosen to minimize TPS interpolation errors. Dosimetry parameters were entered into the PINNACLE TPS, and dose distributions were subsequently calculated and compared to the original Monte Carlo-derived dose distributions. The new planning technique was able to reproduce brachytherapy dose distributions for all three applicator types, producing dosimetric agreement typically within 2% when compared with Monte Carlo-derived dose distributions. Agreement between Monte Carlo-derived and planned dose distributions improved as the spatial resolution of the fitted dosimetry parameters improved. For agreement within 5% throughout the clinical volume, spatial resolution of dosimetry parameter data {<=}0.1 cm was required, and the virtual brachytherapy source data set included over 5000 data points. On the other hand, the lack of consideration for applicator heterogeneity effect caused conventional dose overestimates exceeding an order of magnitude in regions of clinical interest. This approach is rationalized by the improved dose estimates. In conclusion, a new technique was developed to incorporate complex Monte Carlo-based brachytherapy dose distributions into conventional TPS. These results are generalizable to other brachytherapy source types and other TPS.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-BRE-16: VMAT Commissioning and Quality Assurance (QA) of An Elekta Synergy-STM Linac Using ICOM Test HarnessTM

Purpose: To establish a set of tests based on the iCOM software that can be used to commission and perform periodic QA of VMAT delivery on the Elekta Synergy-S, commonly known as the Beam Modulator (BM). Methods: iCOM is used to create and deliver customized treatment fields to characterize the system in terms of 1) MLC positioning accuracy under static and dynamic delivery with full gantry rotation, 2) MLC positioning with known errors, 3) Maximum dose rate, 4) Maximum MLC speed, 5) Maximum gantry speed, 6) Synchronization: gantry speed versus dose rate, and 7) Synchronization: MLC speed versus dose rate. The resulting images were captured on the iView GT and exported in DICOM format to Dosimetry Check™ system for visual and quantitative analysis. For the initial commissioning phase, the system tests described should be supplemented with extensive patient QAs covering all clinically relevant treatment sites. Results: The system performance test suite showed that on our Synergy-S, MLC positioning was accurate under both static and dynamic deliveries. Intentional errors of 1 mm were also easily identified on both static and dynamic picket fence tests. Maximum dose rate was verified with stop watch to be consistently between 475-480 MU/min. Maximum gantry speed and MLC speed were 5.5 degree/s and 2.5 cm/s respectively. After accounting for beam flatness, both synchronization tests, gantry versus dose rate and MLC speed versus dose rate, were successful as the fields were uniform across the strips and there were no obvious cold/hot spots. Conclusion: VMAT commissioning and quality assurance should include machine characterization tests in addition to patient QAs. Elekta iCOM is a valuable tool for the design of customized VMAT field with specific MU, MLC leaf positions, dose rate, and indirect control of MLC and gantry speed at each of its control points.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-J-153: Reconstructing 4D Cone Beam CT Images for Clinical QA of Lung SABR Treatments

Purpose: To verify that the planned Primary Target Volume (PTV) and Internal Gross Tumor Volume (IGTV) fully enclose a moving lung tumor volume as visualized on a pre-SABR treatment verification 4D Cone Beam CT. Methods: Daily 3DCBCT image sets were acquired immediately prior to treatment for 10 SABR lung patients using the on-board imaging system integrated into a Varian TrueBeam (v1.6: no 4DCBCT module available). Respiratory information was acquired during the scan using the Varian RPM system. The CBCT projections were sorted into 8 bins offline, both by breathing phase and amplitude, using in-house software. An iterative algorithm based on total variation minimization, implemented in the open source reconstruction toolkit (RTK), was used to reconstruct the binned projections into 4DCBCT images. The relative tumor motion was quantified by tracking the centroid of the tumor volume from each 4DCBCT image. Following CT-CBCT registration, the planning CT volumes were compared to the location of the CBCT tumor volume as it moves along its breathing trajectory. An overlap metric quantified the ability of the planned PTV and IGTV to contain the tumor volume at treatment. Results: The 4DCBCT reconstructed images visibly show the tumor motion. The mean overlap between the planned PTV (IGTV) and the 4DCBCT tumor volumes was 100% (94%), with an uncertainty of 5% from the 4DCBCT tumor volume contours. Examination of the tumor motion and overlap metric verify that the IGTV drawn at the planning stage is a good representation of the tumor location at treatment. Conclusion: It is difficult to compare GTV volumes from a 4DCBCT and a planning CT due to image quality differences. However, it was possible to conclude the GTV remained within the PTV 100% of the time thus giving the treatment staff confidence that SABR lung treatements are being delivered accurately.

60 APPLIED LIFE SCIENCES↗

SU-E-T-500: Initial Implementation of GPU-Based Particle Swarm Optimization for 4D IMRT Planning in Lung SBRT

Purpose 4D-IMRT planning, combined with dynamic MLC tracking delivery, utilizes the temporal dimension as an additional degree of freedom to achieve improved OAR-sparing. The computational complexity for such optimization increases exponentially with increase in dimensionality. In order to accomplish this task in a clinically-feasible time frame, we present an initial implementation of GPU-based 4D-IMRT planning based on particle swarm optimization (PSO). Methods The target and normal structures were manually contoured on ten phases of a 4DCT scan of a NSCLC patient with a 54cm3 right-lower-lobe tumor (1.5cm motion). Corresponding ten 3D-IMRT plans were created in the Eclipse treatment planning system (Ver-13.6). A vendor-provided scripting interface was used to export 3D-dose matrices corresponding to each control point (10 phases × 9 beams × 166 control points = 14,940), which served as input to PSO. The optimization task was to iteratively adjust the weights of each control point and scale the corresponding dose matrices. In order to handle the large amount of data in GPU memory, dose matrices were sparsified and placed in contiguous memory blocks with the 14,940 weight-variables. PSO was implemented on CPU (dual-Xeon, 3.1GHz) and GPU (dual-K20 Tesla, 2496 cores, 3.52Tflops, each) platforms. NiftyReg, an open-source deformable image registration package, was used to calculate the summed dose. Results The 4D-PSO plan yielded PTV coverage comparable to the clinical ITV-based plan and significantly higher OAR-sparing, as follows: lung Dmean=33%; lung V20=27%; spinal cord Dmax=26%; esophagus Dmax=42%; heart Dmax=0%; heart Dmean=47%. The GPU-PSO processing time for 14940 variables and 7 PSO-particles was 41% that of CPU-PSO (199 vs. 488 minutes). Conclusion Truly 4D-IMRT planning can yield significant OAR dose-sparing while preserving PTV coverage. The corresponding optimization problem is large-scale, non-convex and computationally rigorous. Our initial results indicate that GPU-based PSO with further software optimization can make such planning clinically feasible. This work was supported through funding from the National Institutes of Health and Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-F-T-288: Impact of Trajectory Log Files for Clarkson-Based Independent Dose Verification of IMRT and VMAT

Purpose: To investigate the effect of the trajectory files from linear accelerator for Clarkson-based independent dose verification in IMRT and VMAT plans. Methods: A CT-based independent dose verification software (Simple MU Analysis: SMU, Triangle Products, Japan) with a Clarksonbased algorithm was modified to calculate dose using the trajectory log files. Eclipse with the three techniques of step and shoot (SS), sliding window (SW) and Rapid Arc (RA) was used as treatment planning system (TPS). In this study, clinically approved IMRT and VMAT plans for prostate and head and neck (HN) at two institutions were retrospectively analyzed to assess the dose deviation between DICOM-RT plan (PL) and trajectory log file (TJ). An additional analysis was performed to evaluate MLC error detection capability of SMU when the trajectory log files was modified by adding systematic errors (0.2, 0.5, 1.0 mm) and random errors (5, 10, 30 mm) to actual MLC position. Results: The dose deviations for prostate and HN in the two sites were 0.0% and 0.0% in SS, 0.1±0.0%, 0.1±0.1% in SW and 0.6±0.5%, 0.7±0.9% in RA, respectively. The MLC error detection capability shows the plans for HN IMRT were the most sensitive and 0.2 mm of systematic error affected 0.7% dose deviation on average. Effect of the MLC random error did not affect dose error. Conclusion: The use of trajectory log files including actual information of MLC location, gantry angle, etc should be more effective for an independent verification. The tolerance level for the secondary check using the trajectory file may be similar to that of the verification using DICOM-RT plan file. From the view of the resolution of MLC positional error detection, the secondary check could detect the MLC position error corresponding to the treatment sites and techniques. This research is partially supported by Japan Agency for Medical Research and Development (AMED)

60 APPLIED LIFE SCIENCES↗

Constructing Hardware in a Scale Embedded Language

Chisel is a new open-source hardware construction language developed at UC Berkeley that supports advanced hardware design using highly parameterized generators and layered domain-specific hardware languages. Chisel is embedded in the Scala programming language, which raises the level of hardware design abstraction by providing concepts including object orientation, functional programming, parameterized types, and type inference. From the same source, Chisel can generate a high-speed C++-based cycle-accurate software simulator, or low-level Verilog designed to pass on to standard ASIC or FPGA tools for synthesis and place and route.

Bachan, John↗

ACME Priority Metrics (A-PRIME)

A-PRIME, is a collection of scripts designed to provide Accelerated Climate Model for Energy (ACME) model developers and analysts with a variety of analysis of the model needed to determine if the model is producing the desired results, depending on the goals of the simulation. The software is csh scripts based at the top level to enable scientist to provide the input parameters. Within the scripts, the csh scripts calls code to perform the postprocessing of the raw data analysis and create plots for visual assessment.

Evans, KatherineJ.↗

Image Search for Scientific Data (camBIR) v1.0

camBIR is the CAMERA based image retrieval, a software that takes several different kinds of imagery, such as 2 dimensional images, both scientific as well as non scientific. camBIR is specially designed for training different kinds of Deep Convolutional Neural Network, including new Deep Learning architectures, such as ResNet, Inception-ResNet, NasNet, DenseNet…. It can be used to automate the classification, sort and rank of X-ray imagery such as microCT, GISAXS, GIWAXS, SAXS and WAXS.

Ushizima, Daniela↗