Search NASA⌕ Search

SEARCH · Search NASA

Results for “source characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Effects of gamma, electron beam, and X-ray irradiation on the plastic components of a universal bone cement mixer medical device

Due to market and regulatory pressures, many healthcare manufacturers are considering alternatives to cobalt-60 gamma radiation, including accelerator-based electron beam (E-beam) and X-ray radiation for product sterilization. In this work, the effects of irradiation on a representative medical product, comprised of eight distinct polymer materials, were directly compared for three radiation technologies – cobalt-60 gamma, E-beam, and X-ray – at four dose levels (15, 25, 50, and 70 kGy). The objective was to determine how radiation effects (deleterious or beneficial) are influenced by source and dose level, with the specific goal of determining whether E-beam radiation and/or X-ray radiation could be viable alternatives to gamma radiation for device sterilization. Here, the specific product considered is a single-use medical device for orthopedic surgery, the Stryker Instruments MixeVac III bone cement mixer, which is currently sterilized using gamma radiation from cobalt-60 sources. Following ASTM International standards and input from the manufacturer, we characterized the effects of the three radiation sources on product functionality as well as on the mechanical and optical properties of the constituent polymers. Results indicate that although measurable differences in properties between the standard gamma irradiated materials and the alternative E-beam and X-ray irradiated materials were observed, those differences were small. Statistically significant differences were noted in the case of yellowness index for polyvinyl chloride, high-density polyethylene, and polycarbonate, and in the case of tensile elongation at break for high impact polystyrene and polyvinyl chloride. In general, the results of this study support the viability of E-beam and X-ray radiation as alternative options to cobalt-60 gamma radiation for sterilization of Stryker single-use universal bone cement mixer medical devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Seismoacoustic Analysis of the Large Surface Explosion Coupling Experiment Using a Large- N Seismic Array

Seismoacoustic signals at local distance (<~10 km) are widely used as important constraints on source parameters for near-surface events, yet the seismoacoustic wave generation and energy partitioning are not fully understood. Spatially dense sensors could provide observations in high resolution to capture the full wavefield for better understanding wave propagation and improving source estimation. Recently, spatially dense observations of the local seismoacoustic wavefield produced by a pair of 1-ton surface explosions have been recorded using a large-N seismic array. This large-N array consists of 446 geophones and covers an area of approximately 2×2.5 km 2 . The two surface explosions occur at the same location but at different times with different atmospheric conditions. Both seismic and air–ground coupled acoustic waves from the two surface explosions are well observed. Analyses of signals recorded by the large-N seismic array show different acoustic wave speed and amplitude for the two explosions. A strong spatial variability in acoustic wave speed and amplitude for each explosion is also observed. Finally, the observations suggest the important role of local atmosphere state on wave propagation and source estimation and demonstrate how the use of a large-N capability can improve characterization of the propagation medium and source.

58 GEOSCIENCES↗

The challenge: Safe management on spent and disused sealed radioactive source in Thailand - 15654

When sealed radioactive sources are no longer in use, they should be returned back to the country of origin. However, most of them could not be returned to the country of origin, therefore the safety management of spent and disused radioactive source is need. Thailand Institute of Nuclear Technology (TINT) where is as the national waste management center, has the duty to ensure on the safety and the security for long term storage of spent and disused sealed sources before final disposal. The Radioactive Waste Management Center at TINT, is authorized to operate treatment, conditioning and storage of radioactive waste. This paper will describe the proper operational procedures on characterization technique, identification of unknown sources, volume reduction technique, re-packaging, registration and record keeping of spent and disused radioactive source. The successful results exhibit that the record keeping of spent and disused source is developed, and the national inventory of spent and disused source is up to date. This paper would confirm the safety management of radioactive waste in Thailand. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evidence for autotrophic growth of purple sulfur bacteria using pyrite as electron and sulfur source

ABSTRACT Purple sulfur bacteria (PSB) are capable of anoxygenic photosynthesis via oxidizing reduced sulfur compounds and are considered key drivers of the sulfur cycle in a range of anoxic environments. In this study, we show that Allochromatium vinosum (a PSB species) is capable of autotrophic growth using pyrite as the electron and sulfur source. Comparative growth profile, substrate characterization, and transcriptomic sequencing data provided valuable insight into the molecular mechanisms underlying the bacterial utilization of pyrite and autotrophic growth. Specifically, the pyrite-supported cell cultures (“py”’) demonstrated robust but much slower growth rates and distinct patterns from their sodium sulfide-amended positive controls. Up to ~200-fold upregulation of genes encoding various c - and b -type cytochromes was observed in “py,” pointing to the high relevance of these molecules in scavenging and relaying electrons from pyrite to cytoplasmic metabolisms. Conversely, extensive downregulation of genes related to LH and RC complex components indicates that the electron source may have direct control over the bacterial cells’ photosynthetic activity. In terms of sulfur metabolism, genes encoding periplasmic or membrane-bound proteins (e.g., FccAB and SoxYZ) were largely upregulated, whereas those encoding cytoplasmic proteins (e.g., Dsr and Apr groups) are extensively suppressed. Other notable differentially expressed genes are related to flagella/fimbriae/pilin(+), metal efflux(+), ferrienterochelin(−), and [NiFe] hydrogenases(+). Characterization of the biologically reacted pyrite indicates the presence of polymeric sulfur. These results have, for the first time, put the interplay of PSB and transition metal sulfide chemistry under the spotlight, with the potential to advance multiple fields, including metal and sulfur biogeochemistry, bacterial extracellular electron transfer, and artificial photosynthesis. IMPORTANCE Microbial utilization of solid-phase substrates constitutes a critical area of focus in environmental microbiology, offering valuable insights into microbial metabolic processes and adaptability. Recent advancements in this field have profoundly deepened our knowledge of microbial physiology pertinent to these scenarios and spurred innovations in biosynthesis and energy production. Furthermore, research into interactions between microbes and solid-phase substrates has directly linked microbial activities to the surrounding mineralogical environments, thereby enhancing our understanding of the relevant biogeochemical cycles. Our study represents a significant step forward in this field by demonstrating, for the first time, the autotrophic growth of purple sulfur bacteria using insoluble pyrite (FeS2) as both the electron and sulfur source. The presented comparative growth profiles, substrate characterizations, and transcriptomic sequencing data shed light on the relationships between electron donor types, photosynthetic reaction center activities, and potential extracellular electron transfer in these organisms capable of anoxygenic photosynthesis. Furthermore, the findings of our study may provide new insights into early-Earth biogeochemical evolutions, offering valuable constraints for understanding the environmental conditions and microbial processes that shaped our planet’s history.

59 BASIC BIOLOGICAL SCIENCES↗

NGC 1980 Is Not a Foreground Population of Orion: Spectroscopic Survey of Young Stars with Low Extinction in Orion A

We perform a spectroscopic survey of the foreground population in Orion A with MMT/Hectospec. We use these data, along with archival spectroscopic data and photometric data, to derive spectral types, extinction values, and masses for 691 stars. Using the Spitzer Space Telescope data, we characterize the disk properties of these sources. We identify 37 new transition disk (TD) objects, 1 globally depleted disk candidate, and 7 probable young debris disks. We discover an object with a mass of less than 0.018–0.030 M {sub ⊙}, which harbors a flaring disk. Using the H α emission line, we characterize the accretion activity of the sources with disks, and confirm that the fraction of accreting TDs is lower than that of optically thick disks (46% ± 7% versus 73% ± 9%, respectively). Using kinematic data from the Sloan Digital Sky Survey and APOGEE INfrared Spectroscopy of the Young Nebulous Clusters program (IN-SYNC), we confirm that the foreground population shows similar kinematics to their local molecular clouds and other young stars in the same regions. Using the isochronal ages, we find that the foreground population has a median age of around 1–2 Myr, which is similar to that of other young stars in Orion A. Therefore, our results argue against the presence of a large and old foreground cluster in front of Orion A.

79 ASTRONOMY AND ASTROPHYSICS↗

In situ temperature synthesis and characterization of ferroelectric PZN-4.5PT nanoparticles’ thin films using synchrotron light source

Despite the excellent properties of Pb(Zn 1/3 Nb 2/3 )O 3 -4.5PbTiO 3 (PZN-4.5PT) single crystals, the greatest difficulty for their application on electronic devices is to make them to thin layers related to the difficulty to make them as ceramic materials. In this paper, we use the combined USAXS/SAXS/WAXS instrument at 9ID beamline at APS-ANL for in situ characterization of PZN-4.5PT inorganic perovskite nanoparticles thin films deposited on nanotextured silicon to understand the phase transitions and determine the observed microcrystals' structure. Here, the sample was annealed from ambient to 1000°C. The results revealed structure changes in the nanoparticles' thin films which could be explained by the new phase that can be assigned to the Pb 3 (PO 4 )2-based component. The peak at 31° indicates the presence of the rhombohedral phase perovskites assigned to the nanoparticles. WAXS characterization permitted to identification of many transitions during thermal annealing like dehydration or dihydroxylation of phosphorus gel -OH bonds and internal water.

36 MATERIALS SCIENCE↗

Microdischarge extreme ultraviolet source with alkali metal vapor for surface morphology application

We have characterized a discharge-produced potassium plasma extreme ultraviolet (XUV) source. Potassium ions produced strong broadband emission around 40 nm with a bandwidth of 8 nm (full width at half-maximum). By comparison with atomic structure calculations, the broadband emission is found to be primarily due to 3d-3p transitions in potassium ions ranging from K{sup 2+} to K{sup 4+}. The current-voltage characteristics of the microdischarge suggest that the source operates in a hollow cathode mode and consequently the emitting ions may be localized on the potassium electrode surface at the hole into the capillary. To understand the spectral behavior from the potassium plasmas we compared the spectra from the discharge-produced plasma with that from a laser-produced plasma. The spectra from the different (electric and laser) plasmas at the same electron temperature (12 eV) were almost the same. This compact capillary XUV source with a photon energy of 30 eV is a useful XUV emission source for surface morphology applications.

74 ATOMIC AND MOLECULAR PHYSICS↗

Direction-dependent Corrections in Polarimetric Radio Imaging. I. Characterizing the Effects of the Primary Beam on Full-Stokes Imaging

Next generation radio telescope arrays are being designed and commissioned to accurately measure polarized intensity and rotation measures (RMs) across the entire sky through deep, wide-field radio interferometric surveys. Radio interferometer dish antenna arrays are affected by direction-dependent (DD) gains due to both instrumental and atmospheric effects. In this paper, we demonstrate the effect of DD errors of the parabolic dish antenna array on the measured polarized intensities of radio sources in interferometric images. We characterize the extent of polarimetric image degradation due to the DD gains through wide-band VLA simulations of representative point-source simulations of the radio sky at L band (1–2 GHz). We show that at the 0.5 gain level of the primary beam there is significant flux leakage from Stokes I to Q , U amounting to 10% of the total intensity. We further demonstrate that while the instrumental response averages down for observations over large parallactic angle intervals, full-polarization DD correction is required to remove the effects of DD leakage. We also explore the effect of the DD beam on the RM signals and show that while the instrumental effect is primarily centered around 0 rad-m{sup −2}, the effect is significant over a broad range of RM requiring full polarization DD correction to accurately reconstruct the RM synthesis signal.

79 ASTRONOMY AND ASTROPHYSICS↗

Pinned Clouds over Industrial Sources of Heat during TRACER

An analysis of stereo-camera data from the Tracking Aerosol Convection Interactions Experiment (TRACER) campaign in Houston, Texas, reveals the existence of pinned clouds sitting atop industrial heat sources. These are not plumes of vapor and condensate emanating from stacks: The pinned shallow cumuli have cloud bases at about the lifting condensation of near-surface air. On many mornings, the pinned clouds are the only shallow cumuli in the field of view of the stereo cameras, persisting by themselves for at least an hour. On those mornings, the lower atmosphere straddles the boundary between stable and unstable, and the waste heat from industrial facilities is able to pin moist convection overhead. When solar heating of the surface becomes sufficient later in the morning, those mornings transition to having widespread shallow moist convection. Occurring within the field of view of the stereo cameras and other TRACER instruments, these pinned clouds represent steady plume-like moist convection triggered by known heat sources in a well-characterized atmosphere, making them a rich target for further study. Significance Statement This article introduces steady-state cumulus clouds observed during the Tracking Aerosol Convection Interactions Experiment (TRACER) campaign that were pinned to industrial heat sources. These pinned clouds were present in the early morning only when conditions were primed for moist convection, but for which there was not yet enough solar heating to trigger widespread convection. They persist in a statistical steady state and therefore provide a natural setting to explore the mechanisms controlling convective dynamics, which play a central role in Earth’s atmospheric circulation and radiative balance.

Atmosphere↗

The ion-gas-neutral interactions with surfaces-2 (IGNIS-2) facility for the study of plasma–material interactions

The Ion-Gas-Neutral Interactions with Surfaces-2 (IGNIS-2) surface science facility has been designed at the Pennsylvania State University with the specific purpose of enabling experiments to study plasma–material interactions. This in situ surface modification and characterization facility consists of multiple reconfigurable substations that are connected through a central transfer chamber. This fully connected vacuum system ensures that the physical and chemical properties of samples are not altered between surface modification and analysis. The modification techniques in IGNIS-2 include a low-energy (<300 eV), high-flux (up to 1016 cm−2 s−1) broad-beam ion source, a liquid metal dropper, a lithium injection system, an RF sputter source, and an evaporator. Its characterization techniques include charged particle-based techniques, such as low-energy ion scattering (enabled by two <5 keV ion sources) and x-ray photoelectron spectroscopy, and photon and light-based techniques, such as x-ray fluorescence, multi-beam optical stress sensors, and optical cameras. All of these techniques can be utilized up to mTorr pressures, allowing both in situ and in operando studies to be conducted. Results are presented on lithium wetting experiments of argon-irradiated tungsten-based composites, surface stress measurements of tungsten films during deuterium ion irradiation, and temperature-programmed desorption of deuterium-irradiated graphite to demonstrate the in situ capabilities of this new facility.

Instruments & Instrumentation↗

Simulation evaluation of NIST air-kerma rate calibration standard for electronic brachytherapy: Simulation of NIST air-kerma rate eBT calibration standard

Purpose: Dosimetry for the model S700 50 kV electronic brachytherapy (eBT) source (Xoft, Inc., a subsidiary of iCAD, San Jose, CA) was simulated using Monte Carlo (MC) methods by Rivard et al. [“Calculated and measured brachytherapy dosimetry parameters in water for the Xoft Axxent x-ray source: An electronic brachytherapy source,” Med. Phys. 33, 4020–4032 (2006)] and recently by Hiatt et al. [“A revised dosimetric characterization of the model S700 electronic brachytherapy source containing an anode-centering plastic insert and other components not included in the 2006 model,” Med. Phys. 42, 2764–2776 (2015)] with improved geometric characterization. Additionally, while these studies examined the dose distribution in water, there have not previously been reports of the eBT source calibration methods beyond that recently reported by Seltzer et al. [“New national air-kerma standard for low-energy electronic brachytherapy sources,” J. Res. Natl. Inst. Stand. Technol. 119, 554–574 (2014)]. Therefore, the motivation for the current study was to provide an independent determination of air-kerma rate at 50 cm in air K air (d = 50 cm) using MC methods for the model S700 eBT source. Methods: Using CAD information provided by the vendor and disassembled sources, an MC model was created for the S700 eBT source. Simulations were run using the mcnp6 radiation transport code for the NIST Lamperti air ionization chamber according to specifications by Boutillon et al. [“Comparison of exposure standards in the 10-50 kV x-ray region,” Metrologia 5, 1–11 (1969)], in air without the Lamperti chamber, and in vacuum without the Lamperti chamber. K air (d = 50 cm) was determined using the *F4 tally with NIST values for the mass energy-absorption coefficients for air. Photon spectra were evaluated over 2π azimuthal sampling for polar angles of 0° ≤ θ ≤ 180° every 1°. Volume averaging was averted through tight radial binning. Photon energy spectra were determined over all polar angles in both air and vacuum using the F4 tally with 0.1 keV resolution. A total of 10 11 simulated histories were run for the Lamperti chamber geometry (statistical uncertainty of 0.14%), with 10 10 histories for the in-air and in-vacuum simulations (statistical uncertainty of 0.04%). The total standard uncertainty in the calculated air-kerma rate determination amounted to 6.8%. Results: MC simulations determined the air-kerma rate at 50 cm from the source with the modeled Lamperti chamber to be (1.850 ± 0.126) × 10 -4 Gy/s, which was within the range of K air (d = 50 cm) values (1.67–2.11) × 10 -4 Gy/s measured by NIST. The ratio of the photon spectra in air and in vacuum were in good agreement above 13 keV, and for θ < 150° where the influence of the Kovar sleeve and the Ag epoxy components caused increased scatter in air. Below 13 keV, the ratio of the photon spectra in air to vacuum exhibited a decrease that was attributed to increased attenuation of the photons in air. Across most of the energy range on the source transverse plane, there was good agreement between the authors' simulated spectra and that measured by NIST. Discrepancies were observed above 40 keV where the NIST spectrum had a steeper fall-off towards 50 keV. Conclusions: Through MC simulations of radiation transport, this study provided an independent validation of the measured air-kerma rate at 50 cm in air at NIST for the model S700 eBT source, with mean results in agreement within 3.3%. Lastly, this difference was smaller than the range (i.e., 23%) of the measured values.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization of a hybrid target multi-keV x-ray source by a multi-parameter statistical analysis of titanium K-shell emission

We studied the titanium K-shell emission spectra from multi-keV x-ray source experiments with hybrid targets on the OMEGA laser facility. Using the collisional-radiative TRANSPEC code, dedicated to K-shell spectroscopy, we reproduced the main features of the detailed spectra measured with the time-resolved MSPEC spectrometer. We developed a general method to infer the N e , T e and T i characteristics of the target plasma from the spectral analysis (ratio of integrated Lyman-α to Helium-α in-band emission and the peak amplitude of individual line ratios) of the multi-keV x-ray emission. Finally, these thermodynamic conditions are compared to those calculated independently by the radiation-hydrodynamics transport code FCI2.

42 ENGINEERING↗

Micro-Photoluminescence Characterization of Low Density Droplet GaAs Quantum Dots for Single Photon Sources

The GaAs quantum dots in AlGaAs barriers were grown by droplet epitaxy, emitting around 700 nm in wavelength which is compatible with low cost Si based detectors. The excitation power dependent and time resolved micro-photoluminescence measurements identified optical characteristics of exciton and biexciton states which are attributed to good quantum confinements in GaAs QDs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and characterization of a spatially distributed multibeam field emission x-ray source for stationary digital breast tomosynthesis

Digital breast tomosynthesis (DBT) is a limited angle computed tomography technique that can distinguish tumors from its overlying breast tissues and has potentials for detection of cancers at a smaller size and earlier stage. Current prototype DBT scanners are based on the regular full-field digital mammography systems and require partial isocentric motion of an x-ray tube over certain angular range to record the projection views. This prolongs the scanning time and, in turn, degrades the imaging quality due to motion blur. To mitigate the above limitations, the concept of a stationary DBT (s-DBT) scanner has been recently proposed based on the newly developed spatially distributed multibeam field emission x-ray (MBFEX) source technique using the carbon nanotube. The purpose of this article is to evaluate the performance of the 25-beam MBFEX source array that has been designed and fabricated for the s-DBT system. The s-DBT system records all the projection images by electronically activating the multiple x-ray beams from different viewing angles without any mechanical motion. The configuration of the MBFEX source is close to the published values from the Siemens Mammomat system. The key issues including the x-ray flux, focal spot size, spatial resolution, scanning time, beam-to-beam consistency, and reliability are evaluated using the standard procedures. In this article, the authors describe the design and performance of a distributed x-ray source array specifically designed for the s-DBT system. They evaluate the emission current, current variation, lifetime, and focal spot sizes of the source array. An emission current of up to 18 mA was obtained at 0.5x0.3 mm effective focal spot size. The experimentally measured focal spot sizes are comparable to that of a typical commercial mammography tube without motion blurring. Trade-off between the system spatial resolution, x-ray flux, and scanning time are also discussed. Projection images of a breast phantom were collected using the x-ray source array from 25 different viewing angles without motion. These preliminary results demonstrate the feasibility of the proposed s-DBT scanner. The technology has the potential to increase the resolution and reduce the imaging time for DBT. With the present design of 25 views, they demonstrated experimentally the feasibility of achieving 11 s scanning time at full detector resolution with 0.5x0.3 mm source resolution without motion blur. The flexibility in configuration of the x-ray source array will also allow system designers to consider imaging geometries that are difficult to achieve with the conventional single-source rotating approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operating a radio-frequency plasma source on water vapor

A magnetically enhanced radio-frequency (rf) plasma source operating on water vapor has an extensive list of potential applications. In this work, the use of a rf plasma source to dissociate water vapor for hydrogen production is investigated. This paper describes a rf plasma source operated on water vapor and characterizes its plasma properties using a Langmuir probe, a residual gas analyzer, and a spectrometer. The plasma source operated first on argon and then on water vapor at operating pressures just over 300 mtorr. Argon and water vapor plasma number densities differ significantly. In the electropositive argon plasma, quasineutrality requires n{sub i}{approx_equal}n{sub e}, where n{sub i} is the positive ion density. But in the electronegative water plasma, quasineutrality requires n{sub i+}=n{sub i-}+n{sub e}. The positive ion density and electron density of the water vapor plasma are approximately one and two orders of magnitude lower, respectively, than those of argon plasma. These results suggest that attachment and dissociative attachment are present in electronegative water vapor plasma. The electron temperature for this water vapor plasma source is between 1.5 and 4 eV. Without an applied axial magnetic field, hydrogen production increases linearly with rf power. With an axial magnetic field, hydrogen production jumps to a maximum value at 500 W and then saturates with rf power. The presence of the applied axial magnetic field is therefore shown to enhance hydrogen production.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-Destructive Characterization of Engineering Materials Using High-Energy X-rays at the Advanced Photon Source

High energy X-rays can penetrate large components and samples made from engineering alloys. Brilliant synchrotron sources like the Advanced Photon Source (APS) combined with unique experimental setups are increasingly allowing scientists and engineers to non-destructively characterize the state of materials across a range of length scales. In this article, some of the new developments at the APS, namely the high energy diffraction microscopy technique for grain-by-grain maps and aperture-based techniques for aggregate maps, are described.

36 MATERIALS SCIENCE↗