Search NASA⌕ Search

SEARCH · Search NASA

Results for “source configuration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Beyond Californium—A Neutron Generator Alternative for Dosimetry and Instrument Calibration in the U.S.

Many evaluations of neutron survey instruments, area monitors and personal dosimeters rely on neutron reference radiations from 252Cf, a source of spontaneous fission neutrons that produces high dose rates from an almost point source geometry. Its characteristics are generally more favorable when compared to (a,n), photoneutron and reactor-based sources of neutrons. The source is typically used in two standardized configurations: unmoderated, to yield a fission energy spectrum, or placed within a heavy-water moderating sphere to produce a softened spectrum that is more appropriate for evaluating devices used in nuclear power plant work environments. The U.S. Department of Energy (DOE) 252Cf Loan/Lease Program was terminated in 2009, and the replacement of high-activity sources is increasingly cost prohibitive for laboratories that formerly benefited from that program, including the Pacific Northwest National Laboratory (PNNL) and National Institute of Standards and Technology (NIST). Neutron generators, based on the D-T and D-D fusion reactions, are becoming economically competitive with 252Cf and are recognized internationally as important calibration and test standards. Researchers from NIST and PNNLare jointly considering the practicality and technical challenges of implementing neutron generators as calibration standards in the U.S. This article reviews characteristics of isotope-based sources, leading to rationale behind increasing favor of electronically-generated neutron options. The evaluation of a D-T system at PNNL has revealed primary challenges in adapting generators to the task of calibration and testing in which neutron characteristics must be accurately determined. Concepts for modifying the generated neutron spectra to achieve particular targeted spectra, simulating 252Cf or workplace environments, are discussed.

Calibration, californium-252, Dosimeter Irradiatio↗

Operating Characteristics of a 15-cm dia. Ion Engine for Small Planetary Spacecraft

A 15-cm diameter, scaled-down version of the NASA light-weight 30-cm ion engine has been developed for potential application to very small planetary spacecraft. Integration of the 15-cm ion source into 4x15-cm segmented engine configuration results in a 30-cm equivalent engine which can be throttled over a 7-to-1 input power variation with a constant beam current in each of the four segments. Throttling the segmented engine by turning off individual segments can result in a significant decrease in the required service life (and qualification requirements) of the ion source components.

grids segmented ion engine↗

A CLUSTER OF COMPACT RADIO SOURCES IN W40

We present deep 3.6 cm radio continuum observations of the H II region W40 obtained using the Very Large Array (VLA) in its A and B configurations. We detect a total of 20 compact radio sources in a region of 4' x 4', with 11 of them concentrated in a band with 30'' of extent. We also present JHK photometry of the W40 cluster taken with the QUIRC instrument on the University of Hawaii 2.2 m telescope. These data reveal that 15 of the 20 VLA sources have infrared counterparts, and 10 show radio variability with periods less than 20 days. Based on these combined radio and IR data, we propose that eight of the radio sources are candidate ultracompact H II regions, seven are likely to be young stellar objects, and two may be shocked interstellar gas.

79 ASTRONOMY AND ASTROPHYSICS↗

Surface Slope Metrology on Deformable Soft X-ray Mirrors

We report on the current state of surface slope metrology on deformable mirrors for soft x-rays at the Advanced Light Source (ALS). While we are developing techniques for in situ at-wavelength tuning, we are refining methods of ex situ visible-light optical metrology to achieve sub-100-nrad accuracy. This paper reports on laboratory studies, measurements and tuning of a deformable test-KB mirror prior to its use. The test mirror was bent to a much different optical configuration than its original design, achieving a 0.38 micro-radian residual slope error. Modeling shows that in some cases, by including the image conjugate distance as an additional free parameter in the alignment, along with the two force couples, fourth-order tangential shape errors (the so-called bird shape) can be reduced or eliminated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Apparent Monte Carlo Source Convergence Problem with BWR Fuel Depleted with Partial Control Blade Insertion

Oak Ridge National Laboratory (ORNL) and the US Nuclear Regulatory Commission (NRC) have initiated a multiyear project to investigate application of burnup credit (BUC) to boiling-water reactor (BWR) fuel in storage and transportation casks and spent fuel pools (SFPs). Ideally, a single combination of all operating parameters including moderator density and axial burnup profiles, control blade exposure, and others can be identified to allow a simple, bounding approach to BWR BUC. One aspect of this investigation involves examining the effect of control blade insertion during operation on discharged assembly reactivity. In the course of these calculations, an apparent source convergence problem was discovered for fuel that has experienced partial blade insertion for the entire lifetime of the assembly. The source convergence problem appears not to impact k{sub eff}, but it manifests in predictions of the axial fission density profile. This phenomenon is of interest in identifying areas of concern with BWR BUC since it has not been studied as thoroughly as BUC for pressurized-water (PWR) reactor fuel. There may also be interest in this configuration for further study of a realistic source Monte Carlo convergence problem as opposed to some earlier manufactured source convergence problems through careful selection of initial conditions. This summary presents the depletion conditions used to generate the problem, a description of the models, a background based on well-behaved calculations, the identification of the problem, and attempts made to resolve the problem. Only a brief description of the depletion conditions and models is possible within the limited scope of this summary. Finally, conclusions are presented. This summary identifies a source convergence problem in the process of investigating BUC for BWR spent fuel. The depletion scenario which created the depleted fuel and burnable absorber compositions included a control blade inserted in the bottom 14 nodes throughout the entire depletion. This insertion is slightly over half the length of the assembly, and it appears to create two regions of nearly equal reactivity. As expected, one region is near the top of the assembly, and the other region is near the middle of the assembly. This node includes significant {sup 239}Pu generation as a result of rodded operation, but it is also the top node of the full lattice zone. While the calculated k{sub eff} values appear to be statistically equivalent, the axial neutron production profile varies significantly among independent simulations of the same model. A range of standard approaches has been used to attempt to resolve the source convergence problem and determine the true axial neutron production profile. This profile is of interest in cask criticality safety analysis because it influences the interaction among assemblies loaded in the cask. The forthcoming SCALE 6.2 release will include source convergence testing based on Shannon entropy, which may assist in identifying these types of problems in the future. It should be noted that this source convergence problem results from the depletion conditions and the final distribution of fissile and absorber material within the discharged fuel assembly. The results, while entirely generated within the SCALE code system, are representative of any Monte Carlo program attempting to calculate k{sub eff} for such a system. The most important conclusion of this work is that the BUC criticality safety community must be aware of the potential for this type of source convergence problem. Analysts must approach such partially rodded scenarios with caution and critically examine the results. Fortunately, it is extremely unlikely that BWR assemblies would experience the bladed operation necessary to create this particular source convergence problem. These results may also have some bearing on the analysis of PWR BUC for new plant designs such as AP1000 that incorporate significant rodded operations. In a broader context, the source convergence problem identified here could have been magnified if it had occurred in a Monte Carlo depletion simulation. It may be possible to identify this type of problem in a depletion calculation by comparing the apparently converged fluxes between steps to ensure that no oscillations or other serious shifts are occurring. The depletion calculations performed in this work were performed with a two-dimensional deterministic code and are therefore not subject to this problem. These results may also raise questions about the validity of 2D depletion models with extruded geometry in the 3D k{sub eff} calculation. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radiation Sources and Criticality Safety - 14392

This paper consists essentially of a two part discussion concerning the effects that extraneous radiation sources have on fissionable material systems with respect to criticality and criticality safety. The first part (sections 2 and 3) concentrates on a qualitative discussion about extraneous radiation sources and definitions associated with the criticality of neutron chain reacting systems. The second part (section 4), while it does not constitute a rigorous proof, focuses more on the mathematics governing neutron distribution in general and fissionable material systems. The goal of both parts is the same, i.e. to dispel the notion that a subcritical system can be driven critical by simply supplying a source of neutrons to make up losses. Either part, or both, can be relied on as references in situations in which a criticality safety concern is inappropriately raised for situations where extraneous radiation sources are utilized to perform measurements with subcritical configurations of special nuclear materials. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

A SYNCHRONIZED FIR/VUV LIGHT SOURCE AT JEFFERSON LAB

We describe a dual free-electron laser (FEL) configuration on the UV Demo FEL at Jefferson Lab that allows simultaneous lasing at FIR/THz and UV wavelengths. The FIR/THz source would be an FEL oscillator with a short wiggler providing nearly diffraction-limited pulses with pulse energy exceeding 50 microJoules. The FIR source would use the exhaust beam from a UVFEL. The coherent harmonics in the VUV from the UVFEL are out-coupled through a hole. The FIR source uses a shorter resonator with either hole or edge coupling to provide very high power FIR pulses. Simulations indicate excel-lent spectral brightness in the FIR region with over 100 W/cm-1 output.

43 PARTICLE ACCELERATORS↗

Bipolar lead acid battery development

A modular bipolar battery configuration is under development at Johnson Control, Inc. (JCI) and the Jet Propulsion Laboratory (JPL). The battery design, incorporating proven lead acid electrochemistry, yields a rechargeable, high-power source that is light weight and compact. This configuration offers advantages in power capability, weight, and volume over conventional monopolar batteries and other battery chemistries. The lead acid bipolar battery operates in a sealed, maintenance-free mode allowing for maximum application flexibility. It is ideal for high-voltage and high-power applications.

Eskra, Michael↗

Three–Dimensional Acoustic Multipole Waveform Inversion at Yasur Volcano, Vanuatu

Acoustic waveform inversions can provide estimates of volume flow rate and erupted mass, enhancing the ability to estimate volcanic emissions. Previous studies have generally assumed a simple acoustic source (monopole); however, more complex and accurate source reconstructions are possible with a combination of equivalent sources (multipole). We deployed a high–density acoustic network around Yasur volcano, Vanuatu, including acoustic sensors on a tethered aerostat that was moved every ~15–60 min. Using this unique data set we invert for the acoustic multipole source mechanism using a grid search approach for 80 events to examine volume flow rates and dipole strengths. Our method utilizes finite–difference time–domain modeling to obtain the full 3–D Green's functions that account for topography. Inversion results are compared using a monopole–only, multipole (monopole and dipole), simulations that do not include topography, and those that use a subset of sensors. We find that the monopole source is a good approximation when topography is considered. However, initial compression amplitude is not fully captured by a monopole source so source directionality cannot be ruled out. The monopole solution is stable regardless of whether a monopole–only or multipole inversion is performed. Inversions for the dipole components produce estimates consistent with observed source directionality, though these inversions are somewhat unstable given station configurations of typical deployments. Furthermore, our results suggest that infrasound waveform inversion shows promise for realistic quantitative source estimates, but additional work is necessary to fully explore inversion stability, uncertainty, and robustness.

58 GEOSCIENCES↗

Method and apparatus for testing surface characteristics of a material

A method, apparatus and system for testing characteristics of a material sample is provided. The system includes an apparatus configured to house the material test sample while defining a sealed volume against a surface of the material test sample. A source of pressurized fluid is in communication with, and configured to pressurize, the sealed volume. A load applying apparatus is configured to apply a defined load to the material sample while the sealed volume is monitored for leakage of the pressurized fluid. Thus, the inducement of surface defects such as microcracking and crazing may be detected and their effects analyzed for a given material. The material test samples may include laminar structures formed of, for example, carbon cloth phenolic, glass cloth phenolic, silica cloth phenolic materials or carbon-carbon materials. In one embodiment the system may be configured to analyze the material test sample while an across-ply loading is applied thereto.

Johnson, David L.↗

Cooling technique

An apparatus and a method are provided. Use is made of a wick structure configured to receive a liquid and generate vapor in when such wick structure is heated by heat transferred from heat sources to be cooled off. A vapor channel is provided configured to receive the vapor generated and direct said vapor away from the wick structure. In some embodiments, heat conductors are used to transfer the heat from the heat sources to the liquid in the wick structure.

42 ENGINEERING↗

Spherical grating based x-ray Talbot interferometry

Purpose: Grating interferometry is a state-of-the-art x-ray imaging approach, which can acquire information on x-ray attenuation, phase shift, and small-angle scattering simultaneously. Phase-contrast imaging and dark-field imaging are very sensitive to microstructural variation and offers superior contrast resolution for biological soft tissues. However, a common x-ray tube is a point-like source. As a result, the popular planar grating imaging configuration seriously restricts the flux of photons and decreases the visibility of signals, yielding a limited field of view. The purpose of this study is to extend the planar x-ray grating imaging theory and methods to a spherical grating scheme for a wider range of preclinical and clinical applications. Methods: A spherical grating matches the wave front of a point x-ray source very well, allowing the perpendicular incidence of x-rays on the grating to achieve a higher visibility over a larger field of view than the planer grating counterpart. A theoretical analysis of the Talbot effect for spherical grating imaging is proposed to establish a basic foundation for x-ray spherical gratings interferometry. An efficient method of spherical grating imaging is also presented to extract attenuation, differential phase, and dark-field images in the x-ray spherical grating interferometer. Results: Talbot self-imaging with spherical gratings is analyzed based on the Rayleigh–Sommerfeld diffraction formula, featuring a periodic angular distribution in a polar coordinate system. The Talbot distance is derived to reveal the Talbot self-imaging pattern. Numerical simulation results show the self-imaging phenomenon of a spherical grating interferometer, which is in agreement with the theoretical prediction. Conclusions: X-ray Talbot interferometry with spherical gratings has a significant practical promise. Relative to planar grating imaging, spherical grating based x-ray Talbot interferometry has a larger field of view and improves both signal visibility and dose utilization for pre-clinical and clinical applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recovering New Type of Sources by Off-Site Source Recovery Project for WIPP Disposal - 16604

OSRP uses two types of eligible packaging configurations for Cm-244 and Cf-252 disposal to WIPP: an S-100 drum and a 12'' Pipe Overpack (POC) drum. Both types of packaging are WIPP accepted configurations for Contact Handled (CH) waste, which offer different advantages and disadvantages when used in the case of the two isotopes. The S-100 is a poly-shielded type A, 55 gallon drum, containing a 6'' diameter POC. The 12'' POC drum is a type A, 55 gallon drum without the internal poly-shield and with a pipe component of 12'' diameter. The S-100 drum presents the advantage of poly-shielding which is very important for neutron sources, such as the Cf-252, or Cm-244Be, at the expense of reduced internal volume. The 12'' POC drum presents a larger pipe component accommodating many more sources, like Cm-244 alpha emitters or shielded Cf-252, for which the CH dose rate is not an issue. All the sources prepared for disposal to WIPP are required to be special form, as defined in 49 CFR 173.403. When OSRP recovers normal form sources, these can be packaged in a field closable DOT certified Special Form Capsule (SFC) model II or model III, thus becoming special form. These capsules are then packaged in the type-A containers. The difference between the two types of packaging is that the 12'' POC can hold more sources, or a mix of sources and capsules at the expense of less shielding. This becomes important when the TRU content criteria of 100 nCi/g of TRU waste has to be met for the drums that are packaged for WIPP disposal. Measured neutron dose rates for Cm-244 packaged in S-100 agree reasonably well with calculated dose rates based on the models developed with MCNP. Future work will include validating the model for Cm-244 packaged in 12'' POC. A 1:1 ratio of neutron to gamma is expected for Cm-244Be dose rates packaged in S-100 drums. For Cf-252 packaged in S-100 and 12'' POC, the contribution of Cf-250 to the total emission neutron rate had to be taken into account due to the increasing role of Cf-250 as sources age. The uncertainty in the measurement of Cf-252 neutron dose rate for S-100 drum was quite high due to a high neutron background. A larger Cf- 252 source needs to be used for measurements in the future, in order to fully validate the model developed. A better agreement for measured versus calculated rate was obtained for a Cf-252 packaged in 12'' POC. For the WIPP disposal of these sources, OSRP will use the best packaging configuration for these isotopes in order to minimize the dose rate and maximize the TRU content. The S-100 packaging will be used for Cf-252 and Cm-244Be sources, when neutron dose reduction by the poly-shielding is important. Neutron dose rates will be estimated using the new MCNP correlations.

07 ISOTOPE AND RADIATION SOURCES↗

DGEN Aeropropulsion Research Turbofan Source-Diagnostic Test: Experimental Setup and Acoustic-Data Structure

The experimental setup of, and available data from a recent core/combustor-noise source-diagnostic test utilizing a small turbofan engine are described. The 2019 test campaign continued the investigation of the core/combustor-noise component of aircraft-propulsor noise begun in an earlier baseline test, but with a more extensive acoustic-instrumentation layout. The purpose of both tests was to better understand the impact on civilian-transport airport-community noise from turbofan-combustor sources and thereby to lay the foundation for improved noise-prediction methods and noise-mitigation techniques. Simultaneous high-data-rate acoustic measurements were obtained using a circumferential sensor array at the core nozzle exit in conjunction with sideline and farfield microphone arrays. The test matrix contained engine operational points from engine idle to maximum power and was repeated for different circumferential and sideline array configurations, as well as for redundancy. The extensive data set (up to 93 channels of data and various configurations) allows the application of advanced source-separation and phased-array methods to elucidate not only the core-noise structure, but also the propagation characteristics of other propulsion noise sources. The present report provides a detailed description of the different test points, their associated instrumentation layouts, and the structure of the acquired data set. Results from various data analyses are reported separately.

Aeroacoustics↗

Upgrade of the PNNL TEPC and Multisphere Spectrometer

The Pacific Northwest National Laboratory (PNNL) has used two types of instruments, the tissue equivalent proportional counter (TEPC) and the multisphere spectrometer for characterizing neutron radiation fields in support of neutron dosimetry at the Hanford site. The US Department of Energy recently issued new requirements for radiation protection standards in 10 CFR 835 which affect the way that neutron dose equivalent rates are evaluated. In response to the new requirements, PNNL has upgraded the analyses used in conjunction with the TEPC and multisphere. The analysis software for the TEPC was modified for this effort, and a new analysis code was selected for the multisphere. These new analysis techniques were implemented and tested with measurement data that had been collected in previous measurements. In order to test the effectiveness of the changes, measurements were taken in PNNL’s Low Scatter Room using 252Cf sources in both unmoderated and D2O-moderated configurations that generate well-characterized neutron fields. The instruments were also used at Los Alamos National Laboratory (LANL), in their Neutron Free-in-Air calibration room, also using neutron sources that generate well-characterized neutron fields. The results of the software modifications and the measurements are documented in this report. The TEPC measurements performed at PNNL agreed well with accepted dose equivalent rates using the traditional analysis, agreeing with the accepted value to within 13% for both unmoderated and moderated 252Cf sources. When the new analysis was applied to the TEPC measurement data, the results were high compared to the new accepted value. A similar pattern was seen for TEPC measurements at LANL. Using the traditional analysis method, results for all neutron sources showed good agreement with accepted values, nearly always less than 10%. For the new method of analysis, however, the TEPC responded with higher dose equivalent rates than accepted, by as much as 25%. The reason for the overresponse is that there is very little attenuation of the neutrons by tissue, so it cannot match the effect of attenuation by 1 cm of tissue called for in the new standards. This could be corrected with a modified instrument with a thicker wall, or by analytical means that would need to be developed. The multisphere spectrometer performed reasonably well both at PNNL and at LANL. It could produce a neutron spectrum that was similar to the accepted spectrum, and total flux values were usually within 15% of the accepted values. Dose equivalent rates were usually within 18% of the accepted values. The average energies, however, were usually lower than the accepted values. The performance of this instrument could be much better than seen in this study. If PNNL were to add some moderating spheres to its measurement set and calculate a new set of instrument response functions, performance could be improved. The multisphere could then be a more useful instrument for assessing the dose equivalent rate in the workplace.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CoCoMET v1.0: a unified open-source toolkit for atmospheric object tracking and analysis

Advances in performance and analysis capabilities have accelerated the development of object tracking algorithms for atmospheric research. This has resulted in a growing number of studies using Lagrangian tracking techniques to analyze the evolution of atmospheric phenomena and the underlying processes. However, the increasing complexity and variety of tracking algorithms present a steep learning curve for new users and make it difficult for existing users to compare algorithm performance. We introduce CoCoMET (Community Cloud Model Evaluation Toolkit), an open-source toolkit that addresses these issues. CoCoMET simplifies the process of running multiple tracking algorithms simultaneously and analyzing objects in both model and observational datasets by specifying parameters in a single configuration file. It standardizes input data from different sources into a consistent format and unifies the tracking output across algorithms. CoCoMET enhances the functionality of existing tracking methods by calculating additional properties such as cell growth and dissipation rates, perimeter, surface area, convexity, and irregularity. In addition, CoCoMET includes a novel method for identifying mergers and splits in 2D and 3D tracks and supports the integration of Eulerian/stationary datasets external to the tracking data for process studies. Its potential utility is demonstrated through examples of model intercomparison, model evaluation against observations, and comparisons between tracking algorithms. Designed for open-source environments, CoCoMET will continue to expand with future releases, incorporating more input data types and tracking algorithms.

54 ENVIRONMENTAL SCIENCES↗