Search NASA⌕ Search

SEARCH · Search NASA

Results for “storage performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

I/O in Machine Learning Applications on HPC Systems: A 360-degree Survey

Growing interest in Artificial Intelligence (AI) has resulted in a surge in demand for faster methods of Machine Learning (ML) model training and inference. This demand for speed has prompted the use of high performance computing (HPC) systems that excel in managing distributed workloads. Because data is the main fuel for AI applications, the performance of the storage and I/O subsystem of HPC systems is critical. In the past, HPC applications accessed large portions of data written by simulations or experiments or ingested data for visualizations or analysis tasks. ML workloads perform small reads spread across a large number of random files. This shift of I/O access patterns poses several challenges to modern parallel storage systems. In this paper, we survey I/O in ML applications on HPC systems, and target literature within a 6-year time window from 2019 to 2024. We define the scope of the survey, provide an overview of the common phases of ML, review available profilers and benchmarks, examine the I/O patterns encountered during offline data preparation, training, and inference, and explore I/O optimizations utilized in modern ML frameworks and proposed in recent literature. Lastly, we seek to expose research gaps that could spawn further R&D.

97 MATHEMATICS AND COMPUTING↗

Long-Term Performance of Reference Electrodes in Alkaline Radioactive Waste Storage Environments

Accurate measurements of corrosion potential are important for assessing the likelihood of internal localized corrosion and stress corrosion cracking of carbon steel tanks used for storing radioactive wastes. Reference electrodes in underground radioactive waste storage tanks are challenging to deploy, and more difficult to extract and replace frequently due to radiological exposure and disposal constraints. Hence, electrodes that exhibit stable performance over long periods of immersion in these waste environments are desirable. The present study evaluates the stability of reference electrodes used in radioactive waste storage tanks over a much longer period than previously studied. Long-term tests on Ag/AgCl and Hg/HgO reference electrodes were performed in nonradioactive simulants formulated from wastes stored at the Hanford site. Electrode degradation, which was studied by various in situ and ex situ evaluation techniques, was correlated to changes in electrode fill chemistry from waste intrusion via the porous frit junction. An intentional contamination study was performed to better understand and predict contamination effects on electrode potential drift.

Materials Science↗

Integrated Large-Scale Data Management Platform for Photovoltaic Power Conversion Equipment (PCE) Reliability Data

To meet the demand for accuracy and real-time capability of PV system degradation evaluation, massive volume data is needed to run high-fidelity and high-efficiency simulations and perform advanced data analysis. However, PV farm operators have a series of difficulties with PV inverter data, such as data collection from multiple channels, massive data storage, data management and massive data analysis. To address these challenges, we developed an integrated data management platform capable of data acquisition, processing, storage, query, and performing big data analysis utilizing AI algorithms. The platform can also achieve data correctness verification and provide an effective distributed data management solution to retrieve massive data and establish a connection to distributed computational frameworks.

data management platform↗

Integrated Large-Scale Data Management Platform for Photovoltaic Power Conversion Equipment (PCE) Reliability Data: Preprint

To meet the demand for accuracy and real-time capability of PV system degradation evaluation, massive volume data is needed to run high-fidelity and high-efficiency simulations and perform advanced data analysis. However, PV farm operators have a series of difficulties with PV inverter data, such as data collection from multiple channels, massive data storage, data management and massive data analysis. To address these challenges, we developed an integrated data management platform capable of data acquisition, processing, storage, query, and performing big data analysis utilizing AI algorithms. The platform can also achieve data correctness verification and provide an effective distributed data management solution to retrieve massive data and establish a connection to distributed computational frameworks.

data management↗

Battery Test Manual For 12 Volt Start/Stop Hybrid Electric Vehicles (Revision 1)

This manual was prepared by and for the United Stated Advanced Battery Consortium (USABC) Electrochemical Energy Storage Team. It is based on the targets established for 12 Volt Start/Stop energy storage development and is similar (with some important changes) to an earlier manual for the former FreedomCAR program. The specific procedures were developed primarily to characterize the performance of energy storage devices relative to the USABC requirements. However, it is anticipated that these procedures will have some utility for characterizing 12 Volt Start/Stop hybrid energy storage device behavior in general.

12 Volt Start/Stop↗

Community Energy Storage Thermal Analysis and Management: Cooperative Research and Development Final Report, CRADA Number CRD-11-445

The goal of this project is to create thermal solutions and models for community energy storage devices using both purpose-designed batteries and EV or PHEV batteries. Modeling will be employed to identify major factors of a device's lifetime and performance. Simultaneously, several devices will be characterized to determine their electrical and thermal performance under controlled conditions. After the factors are identified, a variety of thermal design approaches will be evaluated to improve the performance of energy storage devices. Upon completion of this project, recommendations for community energy storage device enclosures, thermal management systems, and/or battery sourcing will be made. NREL's interest is in both new and aged batteries.

25 ENERGY STORAGE↗

Cyclic Performance Analysis of Hydrogen/Bromine Flow Batteries for Grid-Scale Energy Storage

This paper explores the critical factors dominating the cycle performance of the hydrogen/bromine redox flow battery (RFB). Carbon electrode oxidation to CO2 was seen as the dominant side reaction, which can be prevented by operating the cell below 1.4 V. Crossover of bromide species from the positive to the negative electrode, especially during charge, dominates the coulombic efficiency, and can result in dissolution of the Pt catalyst if an adequate hydrogen supply is not maintained. This paper also describes the tradeoffs in voltaic, energy, and coulombic efficiencies during cycling, including the determination of the peak energy efficiency with respect to the HBr concentration and current density. Long-term cycling demonstrates negligible cell-component degradation over 600 cycles (approximate to 3 months), with capacity loss caused by the bromine from the system, which can be mitigated by proper system design. The data and methodologies provided in this paper can be used to understand better the operation of this and other RFBs.

Cho, KT↗

Low-Cost, High-Performance Carbon Fiber for Compressed Natural Gas Storage Tanks (Final Technical Report – Down Select Report)

The aim of this project is to reduce the cost of Type IV, carbon fiber (CF) composite overwrap compressed gas storage tanks by reducing the cost of CF and CF composites. The project team worked to reduce the cost of CF by exploring and testing opportunities for a low-cost alternative precursor material for CF production to supplant market-dominant and costly polyacrylonitrile (PAN). Concurrently, the team aimed to reduce the cost of the tanks at the composite level by improving the interfacial adhesion between the fibers and the matrix resin through the incorporation of low-cost nanoparticles recycled from waste materials, which would reduce the volume of costly CF required to achieve the same tank performance. At the end of the first year, the project team selected mesophase pitch as the primary precursor candidate from a field of materials based on the superior mechanical performance and cost-saving potential. During the second year, the team produced CFs derived from mesophase pitch achieving an average tensile strength of 365.6 ksi and average tensile modulus of 40.74 Msi. Facility availability for spinning and converting these fibers at greater scale has hindered scale-up demonstration, but the team has identified opportunities to conduct this work in the near term. Cost modeling shows that these mesophase pitch-derived CFs can be up to 40% less expensive than PAN-derived CFs due to the lower cost of the feedstock material, higher throughput, greater conversion yield, and lower cost spinning method and compared to PAN. Additionally, the team has demonstrated at lab-scale that nanoparticle coating CFs can significantly increase the interfacial shear strength and load transfer efficiency of CFs in a matrix. Single filament pull-out testing showed a 27% average increase in max interfacial shear strength due to this coating. A continuous method of applying these coatings to a tow of CF has been developed for scale-up. 26 m tows of coated CFs were produced using this system and formed into composite ring samples for ASTM ring burst testing. Issues with the testing protocol have limited assessment of these results. A prototype Type IV tank was designed to meet ANSI HGV2 standards, and the design criteria set out by DOE, using the CF properties developed by the team paired with a proprietary resin matrix, a polyamide liner, and aluminum end bosses. The tank weighs 153.1 kg and with a total capacity of 5.8 kg H2 (5.6 kg usable), which yields a gravimetric capacity of 1.17 kWh/kg. Cost modeling predicts that the tank will have a projected cost of $15.73/kWh. Tank performance modeling does not include considerations for fiber-matrix load transfer efficiency improvements offered by nanoparticle coating method.

08 HYDROGEN↗

Technical assessment of cryo-compressed hydrogen storage tank systems for automotive applications.

On-board and off-board performance and cost of cryo-compressed hydrogen storage are assessed and compared to the targets for automotive applications. The on-board performance of the system and high-volume manufacturing cost were determined for liquid hydrogen refueling with a single-flow nozzle and a pump that delivers liquid H{sub 2} to the insulated cryogenic tank capable of being pressurized to 272 atm. The off-board performance and cost of delivering liquid hydrogen were determined for two scenarios in which hydrogen is produced by central steam methane reforming (SMR) or by central electrolysis. The main conclusions are that the cryo-compressed storage system has the potential of meeting the ultimate target for system gravimetric capacity, mid-term target for system volumetric capacity, and the target for hydrogen loss during dormancy under certain conditions of minimum daily driving. However, the high-volume manufacturing cost and the fuel cost for the SMR hydrogen production scenario are, respectively, 2-4 and 1.6-2.4 times the current targets, and the well-to-tank efficiency is well short of the 60% target specified for off-board regenerable materials.

08 HYDROGEN↗

Glass Bubbles Insulation for Liquid Hydrogen Storage Tanks

A full-scale field application of glass bubbles insulation has been demonstrated in a 218,000 L liquid hydrogen storage tank. This work is the evolution of extensive materials testing, laboratory scale testing, and system studies leading to the use of glass bubbles insulation as a cost efficient and high performance alternative in cryogenic storage tanks of any size. The tank utilized is part of a rocket propulsion test complex at the NASA Stennis Space Center and is a 1960's vintage spherical double wall tank with an evacuated annulus. The original perlite that was removed from the annulus was in pristine condition and showed no signs of deterioration or compaction. Test results show a significant reduction in liquid hydrogen boiloff when compared to recent baseline data prior to removal of the perlite insulation. The data also validates the previous laboratory scale testing (1000 L) and full-scale numerical modeling (3,200,000 L) of boiloff in spherical cryogenic storage tanks. The performance of the tank will continue to be monitored during operation of the tank over the coming years.

Glass bubble↗

LOCO with Constraints and Improved Fitting Technique

LOCO has been a powerful beam-based diagnostics and optics control method for storage rings and synchrotrons worldwide ever since it was established at NSLS by J. Safranek. This method measures the orbit response matrix and optionally the dispersion function of the machine. The data are then fitted to a lattice model by adjusting parameters such as quadrupole and skew quadrupole strengths in the model, BPM gains and rolls, corrector gains and rolls of the measurement system. Any abnormality of the machine that affects the machine optics can then be identified. The resulting lattice model is equivalent to the real machine lattice as seen by the BPMs. Since there are usually two or more BPMs per betatron period in modern circular accelerators, the model is often a very accurate representation of the real machine. According to the fitting result, one can correct the machine lattice to the design lattice by changing the quadrupole and skew quadrupole strengths. LOCO is so important that it is routinely performed at many electron storage rings to guarantee machine performance, especially after the Matlab-based LOCO code became available. However, for some machines, LOCO is not easy to carry out. In some cases, LOCO fitting converges to an unrealistic solution with large changes to the quadrupole strengths {Delta}K. The quadrupole gradient changes can be so large that the resulting lattice model fails to find a closed orbit and subsequent iterations become impossible. In cases when LOCO converges, the solution can have {Delta}K that is larger than realistic and often along with a spurious zigzag pattern between adjacent quadrupoles. This degeneracy behavior of LOCO is due to the correlation between the fitting parameters - usually between neighboring quadrupoles. The fitting scheme is therefore less restrictive over certain patterns of changes to these quadrupoles with which the correlated quadrupoles fight each other and the net effect is very inefficient {chi}{sup 2} reduction, i.e., small {chi}{sup 2} reduction with large changes of {Delta}K. Under effects of random noise, the fitting solution tends to crawl toward these patterns and ends up with unrealistically large {Delta}K. Such a solution is not very useful in optics correction because after the solution is dialed in, the quadrupoles will not respond as predicted by the lattice model due to magnet hysteresis. We will show that adding constraints to the fitting parameters is an effective way to combat this problem of LOCO. In fact, it improves optics calibration precision even for machines that don't show severe degeneracy behavior. LOCO fitting is essentially to solve a nonlinear least square problem with an iterative approach. The linear least square technique is applied in each iteration to move the solution toward the minimum. This approach is commonly referred to as the Gauss-Newton method. By using singular value decomposition (SVD) to invert the Jacobian matrix, this method has generally been very successful for LOCO. However, this method is based on a linear expansion of the residual vector over the fitting parameters which is valid only when the starting solution is sufficiently close to the real minimum. The fitting algorithm can have difficulties to converge when the initial guess is too far off. For example, it's possible for the {chi}{sup 2} merit function to increase after an iteration instead of decrease. This situation can be improved by using more robust nonlinear least square fitting algorithms, such as the Levenberg-Marquardt method. We will discuss the degeneracy problem in section 2 and then show how the constrained fitting can help in section 3. The application of Levenberg-Marquadt method to LOCO is shown in section 4. A summary is given in section 5.

43 PARTICLE ACCELERATORS↗

A systematic approach to resolve high impedance of multifunctional energy storage composites

Previous work has proposed and characterized the structural and electrical performance of Multifunctional Energy Storage Composite (MESC) structures: structural elements with embedded lithium-ion batteries which were developed by the Structures and Composite Laboratory (SACL) at Stanford University. This work conducts a comprehensive parametric study over the design variables in the manufacturing process to determine the root cause of increased DC impedance compared to commercial pouch cell batteries. Several MESC samples were assembled under various controlled environmental temperatures and pressures. The samples underwent Hybrid Peak Pulse Characterization (HPPC) to approximate the DC impedance as a function of state of charge (SOC). Failure limits of the battery with respect to assembly temperature and pressure were tested, and an MESC manufacturing simulation model was constructed in Abaqus to validate the manufacturing limits. Samples assembled without enough temperature or pressure failed due to a lack of structural integrity or hermetic seal. Conversely, samples which underwent elevated temperatures and pressures resulted in high DC impedance due to nonuniform electrolyte wetting. This work resolves the primary concern of MESC by achieving comparable DC impedance to commercial pouch cells of the same chemistry and testing procedure.

25 ENERGY STORAGE↗

Modeling of a thermal energy storage system based on coupled metal hydrides (magnesium iron – sodium alanate) for concentrating solar power plants

Concentrating solar power plants represent low cost and efficient solutions for renewable electricity production only if adequate thermal energy storage systems are included. Metal hydride thermal energy storage systems have demonstrated the potential to achieve very high volumetric energy densities, high exergetic efficiencies, and low costs. The current work analyzes the technical feasibility and the performance of a storage system based on the high temperature Mg 2 FeH 6 hydride coupled with the low temperature Na 3 AlH 6 hydride. To accomplish this, a detailed transport model has been set up and the coupled metal hydride system has been simulated based on a laboratory scale experimental configuration. Proper kinetics expressions have been developed and included in the model to replicate the absorption and desorption process in the high temperature and low temperature hydride materials. The system showed adequate hydrogen transfer between the two metal hydrides, with almost complete charging and discharging, during both thermal energy storage and thermal energy release. The system operating temperatures varied from 450°C to 500°C, with hydrogen pressures between 30 bar and 70 bar. This makes the thermal energy storage system a suitable candidate for pairing with a solar driven steam power plant. The model results, obtained for the selected experimental configuration, showed an actual thermal energy storage system volumetric energy density of about 132 kWh/m 3 , which is more than 5 times the U.S. Department of Energy SunShot target (25 kWh/m 3 ).

14 SOLAR ENERGY↗

Ensuring Profitability of Energy Storage

Energy storage (ES) is a pivotal technology for dealing with the challenges caused by the integration of renewable energy sources. It is expected that a decrease in the capital cost of storage will eventually spur the deployment of large amounts of ES. These devices will provide transmission services, such as spatiotemporal energy arbitrage, i.e., storing surplus energy from intermittent renewable sources for later use by loads while reducing the congestion in the transmission network. This paper proposes a bilevel program that determines the optimal location and size of storage devices to perform this spatiotemporal energy arbitrage. This method aims to simultaneously reduce the system-wide operating cost and the cost of investments in ES while ensuring that merchant storage devices collect sufficient profits to fully recover their investment cost. Finally, the usefulness of the proposed method is illustrated using a representative case study of the ISO New England system with a prospective wind generation portfolio.

25 ENERGY STORAGE↗

A metric for evaluating conformance robustness during geologic CO 2 sequestration operations

A metric for quantifying the robustness of a designation of conformance of a geologic CO 2 sequestration (GCS) project during its operational phase is developed and demonstrated. Conformance in this context is a measure of the degree to which the sequestration system is understood and can be accurately modeled along with the degree to which the storage system is performing as designed. The robustness of conformance quantifies the degree to which parameter values can deviate from their current nominal estimates and still produce model forecasts that meet the performance criteria for the GCS operation. We develop and demonstrate the approach on a simplified scenario to illustrate the concept using a single uncertain parameter (homogeneous reservoir permeability) and a single performance criterion (critical pressure at a monitoring well in the reservoir; i.e., one that may displace brine from the reservoir to an overlying drinking water aquifer for example). Increased confidence in conformance assessment as more monitoring data are obtained is incorporated through the standard error of the coefficient (reservoir permeability in the case presented here), which we designate as the concordance metric. As more monitoring data become available during the course of the GCS operation, the standard error of the coefficient decreases (in general), thereby leading to increased conformance robustness as a larger deviation from nominal is required to fail to meet performance criteria. Increasing conformance robustness over time builds confidence that a GCS project will continue to meet performance criteria during the life-span of the project, thereby supporting designations of conformance. Furthermore a lack of conformance robustness provides a critical warning that the performance criteria of the GCS operation are not robust against probabilistic and non-probabilistic uncertainty in model conceptualization and/or model parameters.

58 GEOSCIENCES↗

New Advanced Stable Electrolytes for High-voltage Electrochemical Energy Storage

To improve the performance, reliability, and safety of Li-ion batteries, new advanced materials need to be integrated into the cell design. Specifically, the DOE roadmap recognizes the importance in the automotive industry of the development of new electrolytes with improved electrochemical and thermal stability for advance cathodes with higher operating voltages, higher energy density, and reduced cost.

25 ENERGY STORAGE↗

Applications of XPS in the characterization of Battery materials

In this study, technological development requires reliable power sources where energy storage devices are emerging as a critical component. Wide range of energy storage devices, Redox-flow batteries (RFB), Lithium ion based batteries (LIB), and Lithium-sulfur (LSB) batteries are being developed for various applications ranging from grid-scale level storage to mobile electronics. Material complexities associated with these energy storage devices with unique electrochemistry are formidable challenge which needs to be address for transformative progress in this field. X-ray photoelectron spectroscopy (XPS) - a powerful surface analysis tool - has been widely used to study these energy storage materials because of its ability to identify, quantify and image the chemical distribution of redox active species. However, accessing the deeply buried solid-electrolyte interfaces (which dictates the performance of energy storage devices) has been a challenge in XPS usage. Herein we report our recent efforts to utilize the XPS to gain deep insight about these interfaces under realistic conditions with varying electrochemistry involving RFB, LIB and LSB.

25 ENERGY STORAGE↗