Search NASA⌕ Search

SEARCH · Search NASA

Results for “time resolved”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Time-Resolved Imaging Of Transient Plasma

Pulsed capillary discharge is a compact device that is used to perform fast electrical discharge that is used to produce transient plasma. In this work, a more economical imaging technique is developed in order to study the dynamics of the plasma that is formed in a capillary tube. The imaging system consists of two main devices, a four-frame gated micro-channel plate and a Nikon Coolpix5000 camera. The time-resolved imaging that we have performed in order to study the dynamics of the plasma that is formed in a 10 mm long and 1 mm diameter low pressure capillary tube is reported. The images obtained portrayed that the plasma is heated up when the magnitude of the current is around the maximum and cools down when the current magnitude is around the minimum.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spin-orbit torque-driven skyrmion dynamics revealed by time-resolved X-ray microscopy

Magnetic skyrmions are topologically protected spin textures with attractive properties suitable for high-density and low-power spintronic device applications. Much effort has been dedicated to understanding the dynamical behaviours of the magnetic skyrmions. However, experimental observation of the ultrafast dynamics of this chiral magnetic texture in real space, which is the hallmark of its quasiparticle nature, has so far remained elusive. Here, we report nanosecond-dynamics of a 100nm-diameter magnetic skyrmion during a current pulse application, using a time-resolved pump-probe soft X-ray imaging technique. We demonstrate that distinct dynamic excitation states of magnetic skyrmions, triggered by current-induced spin-orbit torques, can be reliably tuned by changing the magnitude of spin-orbit torques. Our findings show that the dynamics of magnetic skyrmions can be controlled by the spin-orbit torque on the nanosecond time scale, which points to exciting opportunities for ultrafast and novel skyrmionic appl ications in the future.

36 MATERIALS SCIENCE↗

Time-resolved unsteady shock motion and spectral analysis of a hypersonic shock-wave/boundary-layer interaction over a double-cone

Direct experimental measurements of double-cone shock-wave/boundary-layer interaction dynamics at Mach 7.2 were collected using a schlieren-based shock-detection algorithm at the University of Texas at San Antonio. The points of flow separation and reattachment were spatially and spectrally evaluated at 300 kHz for time-resolved characterization of the unsteadiness of this flow field. The separation bubble was found to rapidly expand and contract about a large mean length. Spectral analysis of the velocity fluctuations of this motion revealed this behavior to be a turbulent phenomenon, with spectral energy trends consistent with the Kolmogorov theory for the turbulent energy cascade.

Glasby, Ryan [ORNL]↗

Time-resolved measurements of double layer evolution in expanding plasma

Observations in steady-state plasmas confirm predictions that formation of a current-free double layer in a plasma expanding into a chamber of larger diameter is accompanied by an increase in ionization upstream of the double layer. The upstream plasma density increases sharply at the same driving frequency at which a double layer appears. For driving frequencies at which no double layer appears, large electrostatic instabilities are observed. Time-resolved measurements in pulsed discharges indicate that the double layer initially forms for all driving frequencies. However, for particularly strong double layers, instabilities appear early in the discharge and the double layer collapses.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Short- vs . long-range elastic distortion: structural dynamics of a [2 × 2] tetrairon( II ) spin crossover grid complex observed by time-resolved X-Ray crystallography

Spin crossover complexes (SCO) are among the most studied molecular switches due to their potential use in displays, sensors, actuators and memory components. A prerequisite to using these materials is the understanding of the structural changes following the spin transition at out-of-equilibrium conditions. So far, out-of-equilibrium studies in SCO solids have been focused on mononuclear complexes, though a growing number of oligonuclear SCO complexes showing cooperative effects are being reported. Here, we use time-resolved pink Laue crystallography to study the out-of-equilibrium dynamics of a [2 × 2] tetranuclear metallogrid of the form [Fe II 4 L Me 4 ](BF 4 ) 4 ·2MeCN ([L Me ] - = 4-methyl-3,5-bis{6-(2,2'-bipyridyl)}pyrazolate). The out-of-equilibrium spin state switching induced by a ps laser pulse demonstrates that the metallogrid exhibits a multi-step response similar to that reported for mononuclear complexes. Contrary to the mononuclear complexes, the metallogrid shows two types of elastic distortions at different time scales. The first is a short-range distortion that propagates over the entire Fe 4 grid complex during the ps time scale, and it is caused by the rearrangement of the coordination sphere of the photo-switching ion and the constant feedback between strongly linked metal ions. The second is a long-range distortion caused by the anisotropic expansion of the lattice during the ns time scale, observed in mononuclear materials. The structural analysis demonstrates that the long-range prevails over the short-range distortion, inducing the largest deformation of both the entire grid and the coordination sphere of each metal ion. The present study sheds light on the out-of -equilibrium dynamics of a non-cooperative oligonuclear complex.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Buried Interface and Luminescent Coupling Analysis with Time-Resolved Two-Photon Excitation Microscopy in II-VI and III-V Semiconductor Heterostructures

Semiconductor heterostructures are used in high-efficiency solar cells and in other electronic devices. Solar cells can't reach thermodynamic efficiency limits in part due to the charge carrier recombination, and efforts are applied to understand and reduce recombination. We describe a novel experimental approach to identify and quantify recombination losses at semiconductor interfaces. Using time-resolved two-photon excitation microscopy, we generate carriers at well-defined absorber depths and find that the red spectral shift of the photoluminescence (PL) emission can be used as a 'spectroscopic ruler' to identify recombination depth up to 30 um. We apply this analysis to quantify Shockley-Read-Hall recombination at the buried CdTe/CdTe interface, where 15 um thick epitaxial CdTe is grown by the molecular beam epitaxy on the single crystal CdTe substrate. We also measure luminescent coupling between the GaInP and GaAs layers in heterostructures grown by the metal-organic chemical vapor deposition. Our results resolve important limitations for accurate 3D charge carrier lifetime tomography. Earlier we analyzed recombination due to extended defects and grain boundaries with the lateral resolution sufficient to resolve such features (approximately 0.5 um), but interpretation of the carrier lifetime microscopy data for buried interfaces and buried semiconductor layers was a challenge. Using methods described here, the axial (z) coordinate for the PL microscopy measurements becomes as well defined as the lateral (x, y) coordinates, enabling accurate 3D identification and analysis of the charge carrier recombination locations in semiconductor heterostructures.

14 SOLAR ENERGY↗

Protein Structural Dynamics of Wild-Type and Mutant Homodimeric Hemoglobin Studied by Time-Resolved X-Ray Solution Scattering

The quaternary transition between the relaxed (R) and tense (T) states of heme-binding proteins is a textbook example for the allosteric structural transition. Homodimeric hemoglobin (HbI) from Scapharca inaequivalvis is a useful model system for investigating the allosteric behavior because of the relatively simple quaternary structure. To understand the cooperative transition of HbI, wild-type and mutants of HbI have been studied by using time-resolved X-ray solution scattering (TRXSS), which is sensitive to the conformational changes. Herein, we review the structural dynamics of HbI investigated by TRXSS and compare the results of TRXSS with those of other techniques.

Yang, Cheolhee↗

In Situ Time-Resolved X-ray Scattering Study of Isotactic Polypropylene in Additive Manufacturing

In this study, we used a specially designed apparatus, which collects simultaneous temperature and X-ray scattering data, to perform in situ measurements of the filament during MatEx 3D printing. The data show that the MatEx 3D printing extrusion process provides sufficient shear to form shish-kebab structures, which initially nucleate at the filament surface and spread into the filament core. Time-resolved measurements show that the kebab component near the surface relaxes after deposition of the second filament and enhances chain diffusion across the interface. SEM images indicate near complete interfacial merging of the filaments, which results in excellent mechanical properties.

36 MATERIALS SCIENCE↗

Establishment of time‐resolved fluoroimmunoassay of IgG4 based on magnetic microspheres

Abstract Background The abnormal increase in serum IgG4 level is an important clinical symptom of IgG4‐related disease (IgG4‐RD), and the detection of serum IgG4 level is a powerful tool for the diagnosis of IgG4‐RD. This study was conducted to establish a simple and rapid immunoassay for the determination of human serum IgG4 levels. Methods Based on the competition method, a novel immunoassay was established for the determination of human serum IgG4 using a combination of time‐resolved fluoroimmunoassay (TRFIA) and magnetic microspheres. IgG4 was coupled with magnetic microspheres and competed with IgG4 in the samples to bind the Eu 3+ ‐labeled anti‐IgG4 antibody. The immunocomplex was separated and washed in a magnetic field, and the fluorescence counts were measured according to the number of dissociated europium ions. Results The analytical sensitivity of IgG4‐TRFIA based on magnetic microspheres was 0.006 g/L, and the detection range was 0.006–20 g/L under optimal conditions. The precision, recovery, and specificity of this immunoassay were demonstrated to be acceptable. The clinical application of IgG4‐TRFIA based on magnetic microspheres was evaluated and compared with that of immunonephelometry. The results showed that the two detection methods had a good correlation, with a correlation coefficient of .9871. Conclusion IgG4‐TRFIA based on magnetic microspheres has the advantages of high sensitivity, wide detection range, and short analysis time and has the potential to become a useful tool for the diagnosis of IgG4‐RD.

Wu, Qingqing↗

Deriving the intermediate spectra and photocycle kinetics from time-resolved difference spectra of bacteriorhodopsin. The simpler case of the recombinant D96N protein

The bacteriorhodopsin photocycle contains more than five spectrally distinct intermediates, and the complexity of their interconversions has precluded a rigorous solution of the kinetics. A representation of the photocycle of mutated D96N bacteriorhodopsin near neutral pH was given earlier (Varo, G., and J. K. Lanyi. 1991. Biochemistry. 30:5008-5015) as BRhv-->K<==>L<==>M1-->M2--> BR. Here we have reduced a set of time-resolved difference spectra for this simpler system to three base spectra, each assumed to consist of an unknown mixture of the pure K, L, and M difference spectra represented by a 3 x 3 matrix of concentration values between 0 and 1. After generating all allowed sets of spectra for K, L, and M (i.e., M1 + M2) at a 1:50 resolution of the matrix elements, invalid solutions were eliminated progressively in a search based on what is expected, empirically and from the theory of polyene excited states, for rhodopsin spectra. Significantly, the average matrix values changed little after the first and simplest of the search criteria that disallowed negative absorptions and more than one maximum for the M intermediate. We conclude from the statistics that during the search the solutions strongly converged into a narrow region of the multidimensional space of the concentration matrix. The data at three temperatures between 5 and 25 degrees C yielded a single set of spectra for K, L, and M; their fits are consistent with the earlier derived photocycle model for the D96N protein.

NASA Program Exobiology↗

Time-resolved dosimetry using a pinpoint ionization chamber as quality assurance for IMRT and VMAT

Purpose: To develop a method to verify the dose delivery in relation to the individual control points of intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) using an ionization chamber. In addition to more effective problem solving during patient-specific quality assurance (QA), the aim is to eventually map out the limitations in the treatment chain and enable a targeted improvement of the treatment technique in an efficient way. Methods: Pretreatment verification was carried out for 255 treatment plans that included a broad range of treatment indications in two departments using the equipment of different vendors. In-house developed software was used to enable calculation of the dose delivery for the individual beamlets in the treatment planning system (TPS), for data acquisition, and for analysis of the data. The observed deviations were related to various delivery and measurement parameters such as gantry angle, field size, and the position of the detector with respect to the field edge to distinguish between error sources. Results: The average deviation of the integral fraction dose during pretreatment verification of the planning target volume dose was −2.1% ± 2.2% (1 SD), −1.7% ± 1.7% (1 SD), and 0.0% ± 1.3% (1 SD) for IMRT at the Radboud University Medical Center (RUMC), VMAT (RUMC), and VMAT at the Wellington Blood and Cancer Centre, respectively. Verification of the dose to organs at risk gave very similar results but was generally subject to a larger measurement uncertainty due to the position of the detector at a high dose gradient. The observed deviations could be related to limitations of the TPS beam models, attenuation of the treatment couch, as well as measurement errors. The apparent systematic error of about −2% in the average deviation of the integral fraction dose in the RUMC results could be explained by the limitations of the TPS beam model in the calculation of the beam penumbra. Conclusions: This study showed that time-resolved dosimetry using an ionization chamber is feasible and can be largely automated which limits the required additional time compared to integrated dose measurements. It provides a unique QA method which enables identification and quantification of the contribution of various error sources during IMRT and VMAT delivery.

60 APPLIED LIFE SCIENCES↗

Time-resolved tracking of cellulose biosynthesis and assembly during cell wall regeneration in live Arabidopsis protoplasts

Cellulose, the most abundant polysaccharide on earth composing plant cell walls, is synthesized by coordinated action of multiple enzymes in cellulose synthase complexes embedded within the plasma membrane. Multiple chains of cellulose fibrils form intertwined extracellular matrix networks. It remains largely unknown how newly synthesized cellulose is assembled into an intricate fibril network on cell surfaces. Here, we have established an in vivo time-resolved imaging platform to continuously visualize cellulose biosynthesis and fibril network assembly onArabidopsis thalianaprotoplast surfaces as the primary cell wall regenerates. Our observations provide the basis for a model of cellulose fibril network development in protoplasts driven by an interplay of multiscale dynamics that includes rapid diffusion and coalescence of nascent cellulose fibrils, processive elongation of single fibrils, and cellulose fibrillar network rearrangement during maturation. This study provides fresh insights into the dynamic and mechanistic aspects of cell wall synthesis at the single-cell level.

Science & Technology - Other Topics↗

Time Resolved 3-D Mapping of Atmospheric Aerosols and Clouds During the Recent ARM Water Vapor IOP

The HARLIE lidar was deployed at the ARM SGP site in north central Oklahoma and recorded over 100 hours of data on 16 days between 17 September and 6 October 2000 during the recent Water Vapor Intensive Operating Period (IOP). Placed in a ground-based trailer for upward looking scanning measurements of clouds and aerosols, HARLIE provided a unique record of time-resolved atmospheric backscatter at 1 micron wavelength. The conical scanning lidar images atmospheric backscatter along the surface of an inverted 90 degree (full angle) cone up to an altitude of 20 km. 360 degree scans having spatial resolutions of 20 meters in the vertical and 1 degree in azimuth were obtained every 36 seconds. Various boundary layer and cloud parameters are derived from the lidar data, as well as atmospheric wind vectors where there is Sufficiently resolved structure that can be traced moving through the surface described by the scanning laser beam. Comparison of HARLIE measured winds with radiosonde measured winds validates the accuracy of this new technique for remotely measuring atmospheric winds without Doppler information.

Schwemmer, Geary↗

Time-resolved interferometric measurements of plasma density evolution in laser-driven capacitor-coil targets

Laser-driven capacitor-coil targets provide a compact platform for generating strong magnetic fields and are widely used in magnetized high-energy-density (HED) plasma experiments. In addition to magnetic-field generation, these targets also produce plasma in the coil region, which can influence the subject physical processes and interact with secondary targets or external plasmas in their applications. However, direct, time-resolved measurements of the plasma density surrounding the coil remain limited. Here, we report interferometric measurements of the plasma density evolution in laser-driven capacitor-coil targets irradiated by the University of Osaka LFEX laser. Two-dimensional electron density maps reveal two distinct plasma sources loading the coil region: plasma generated in the coil itself and plasma produced by laser ablation of the target plates. These results provide quantitative information on plasma loading and evolution in capacitor-coil targets and are directly relevant to the design and modeling of magnetized HED plasma experiments.

Zhang, Yang [Princeton University, NJ (United Stat↗

Visualization of Thermal and Strain Dynamics in X-ray Optics by Time-Resolved Rocking Curve Imaging

The absorption of intense X-ray pulses from free-electron lasers by X-ray crystal optics triggers rapid thermal and mechanical responses, including lattice compression, expan- sion, and strain-wave propagation, which dynamically modify diffraction conditions and wavefront properties. These effects pose significant challenges for next-generation high- repetition-rate X-ray sources, particularly for crystal monochromators used in XFEL beam- lines and self-seeding. Here, we demonstrate time-resolved rocking curve imaging (TrRCI) of X-ray Bragg optics with high spatial resolution (6.4 μm) and sub-1-μrad angular resolu- tion, enabling direct visualization of lattice dynamics from nanoseconds to microseconds. By combining a high-flux beamline at SPring-8, a scintillator-coupled sCMOS detector, and a synchronized femtosecond laser system, we capture lattice dynamics induced by tran- sient laser heating with a strain sensitivity on the order of 10−6 . Our results reveal transient lattice deformation and the propagation of laser-induced strain waves over millimeter-scale distances. This approach provides experimental benchmarks for understanding heat-load effects in high-repetition-rate X-ray optics.

Source record↗

Time-resolved measurement of electron beam neutralization

An intense relativistic electron beam (IREB) incident on a target generates positive ions by stimulated and thermal desorption of adsorbed gas, and subsequent electron impact ionization. These ions are accelerated upstream by the beam space-charge potential, thereby partially neutralizing the beam. If there is enough neutralization, the repulsive space-charge force can be overcome by the magnetic-pinch force due to the beam current. This so-called ion focusing is responsible for time dependent defocusing of the radiographic source spot. Since a single monolayer of adsorbed gas has a surface density of about 10 15 /cm 2 and is formed in about one second in a one micro-Torr vacuum, there is always enough adsorbed gas to make this a concern in our accelerators. Therefore, time-resolved measurements of the degree of neutralization are valuable for better understanding of this process with an eye to mitigation for improvement of our radiography. Moreover, these measurements would aid quantification of uncertainties due to these effects when using invasive beam diagnostics, such as OTR imaging targets.

43 PARTICLE ACCELERATORS↗

Time Resolved Irradiance of an Integrating Sphere Illuminated by a Mode-Locked Optical Parametric Oscillator

Tunable laser based illumination sources have been adopted by a number of recent hyperspectral instruments for pre-launch spectral radiometric calibration. Some of these sources use mode-locked cavity configurations, which produce a pulse train and create an undesirable fluctuation in the radiometric source at the mode locking frequency. Although typically this frequency is several orders of magnitude higher than the instrument response, care must be taken to ensure the resultant calibration is not biased due to detector or electronic saturation effects. The temporal averaging properties of an integrating sphere can be used to reduce high frequency fluctuations to an acceptable level. In this work, the time resolved output of an integrating sphere coupled with a mode-locked source was measured. A 76 cm diameter sphere with 30 cm output aperture was illuminated using a mode-locked pulse train at 76 MHz, with single pulse durations of 12 ps. The time constant of the sphere was found to be 36 ns, and the resultant temporal averaging of pulses produced a maximum time varying irradiance at the output of 20% of the mean. The form of this time variance is a sawtooth pattern, with a sharp rise during the introduction of each pulse into the sphere followed by a slower decay between pulses. A comparison of instrument calibration data generated with this integrating sphere using both a mode locked source and a continuous wave source is also given. .

McAndrew, Brendan↗

A von Hamos x-ray spectrometer based on a segmented-type diffraction crystal for single-shot x-ray emission spectroscopy and time-resolved resonant inelastic x-ray scattering studies

We report on the design and performance of a wavelength-dispersive type spectrometer based on the von Hamos geometry. The spectrometer is equipped with a segmented-type crystal for x-ray diffraction and provides an energy resolution in the order of 0.25 eV and 1 eV over an energy range of 8000 eV-9600 eV. The use of a segmented crystal results in a simple and straightforward crystal preparation that allows to preserve the spectrometer resolution and spectrometer efficiency. Application of the spectrometer for time-resolved resonant inelastic x-ray scattering and single-shot x-ray emission spectroscopy is demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗