Search NASA⌕ Search

SEARCH · Search NASA

Results for “variable generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 793 records · Page 44

Multi-mode power split hybrid transmission with two planetary gear mechanisms

A multi-mode, power-split hybrid transmission system having two planetary gear (PG) sets connected to one engine, two electric motors, one output shaft, and each other by several clutches, brakes, and direct connection elements. Depending on the specific location and actuation of the various clutch and brake elements, the multi-mode, power-split hybrid transmission system can be run in one of several modes (e.g. electric drive, power-split, parallel hybrid, series hybrid, electronic continuously variable transmission (eCVT), generator, neutral, and the like).

33 ADVANCED PROPULSION SYSTEMS↗

Integrated Transportation-Energy Systems Modeling

Transportation is currently the least-diversified energy demand sector, with over 90% of global transportation energy use coming from petroleum product. After over a century of petroleum dominance, however, many leading experts anticipate major electrification trends that could disrupt the transportation energy demand landscape. These changes in electricity demand complement profound changes happening within electric power supply systems, including integration of variable renewables, distributed generation and storage, and greater participation in power system planning and operations from traditionally passive consumers. This broader context underscores the importance of understanding how transportation electrification will impact electricity demand, including changes in the load shapes that characterize the system and the opportunity to leverage flexible EV charging to more cost-effectively balance demand and supply. This talk provides an overview of recent findings on infrastructure requirements to support EV adoption, integration challenges and the impact of EV on power systems, and opportunities to leverage flexible (or smart) EV charging to support power system planning and operations.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Control strategies for coupling thermal energy storage systems with small modular reactors - 188

The contribution of intermittent (renewable) energy sources such as wind and solar continues to increase as renewables improve in both efficiency and price-point. However, the variability of renewables generates additional challenges for the electric grid in the form of rapidly varying electric loads. Proposed options for accommodating this load have included operating nuclear reactors in a load follow mode, or operating the reactor at or near steady state and bypassing steam directly to the condenser. Both of these strategies result in lost energy potential. In addition to lost energy potential, load follow operation can result in increased stress on the fuel and other mechanical components. A more attractive approach is to operate the reactor at or near steady state and bypass excess steam to a thermal energy storage system. The thermal energy can then be recovered, either for electric generation during periods of peak electric demand, or for use in ancillary applications such as desalination and hydrogen production. Sensible Heat Thermal Energy Storage is a mature technology currently used in solar energy systems. This research focuses on the design and coupling of such a system to Small Modular Reactors (SMRs), typical of Integral Pressurized Water Reactor (IPWR) designs currently under development. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Short-term Electricity Price Forecasting with Constrained Regressors

The volatility of electricity price presents a challenge to market participants as their decision-making process are highly depend on the accuracy of price forecasts. However, there is growing empirical evidence of increasing price volatility and price spikes in electricity markets as a result of variable renewable energy generation, extreme weather events, and other factors. The distribution shift caused by spikes in electricity price data differentiates the forecasting tasks from other renewable energy sources. Moreover, the observations may be compromised by cyberattacks and thus not available in the testing phase. To this end, we propose a Similarity-Enhanced Electricity Decomposition Forecasting model (SEED-Forecaster) to address the missing response problem and spikes capturing in short-term electricity price forecasting. The effectiveness of the proposed framework is tested on real-world electricity price data from California Independent System Operator (CAISO). Numerical results of case studies show that the proposed SEED-Forecsater can enhance forecasting performance, particularly in capturing electricity spikes, even under conditions without regressors during testing stage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling and Power-Hardware-in-the-Loop Validation of Synchronous Wind: An Inverterless Grid-Forming Wind Power Plant: Preprint

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators has attracted substantial attention in power systems research; however, the limited over-current capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also known as Type-5 wind turbine generator (WTG), offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high penetration levels of renewable generation. A Type-5 WTG interfaces to the electric grid via a synchronous generator (SG) driven by a variable-speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation and the generator shaft remains synchronous to the grid. This paper developed and tested a high-fidelity model of Type-5 WTG under power-hardware-in-the-loop (PHIL) testing environment. The PHIL demonstration showed that a Type-5 WTGs inherently behaves as a GFM unit and can obtain similar performance in terms of power responses, wind rotor dynamics, and efficiency compared to Type-3 WTG in high wind conditions. The developed model also provides further insight on how Type-5 WTGs can benefit the smooth transition to power systems with high integration level of inverter-based resources.

grid strength↗

Cooling and Heating Season Impacts of Right-Sizing of Fixed- and Variable-Capacity Heat Pumps With Attic and Indoor Ductwork

A new generation of central, ducted variable-capacity heat pump systems has come on the market, promising very high cooling and heating efficiency. They are controlled differently than standard fixed-capacity systems. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they vary their cooling and heating output over a wide range (approximately 40% - 118% of nominal full capacity), thus staying 'on' for 60% - 100% more hours per day compared to fixed -capacity systems. Experiments in this research examined the performance of 2-ton and 3-ton fixed- and variable-capacity systems and the impacts of system oversizing.

BA-PIRC↗

Variable Renewable Energy in Long-Term Planning Models: A Multi-Model Perspective

Long-term capacity expansion models of the U.S. electricity sector have long been used to inform electric sector stakeholders and decision makers. With the recent surge in variable renewable energy (VRE) generators - primarily wind and solar photovoltaics - the need to appropriately represent VRE generators in these long-term models has increased. VRE generators are especially difficult to represent for a variety of reasons, including their variability, uncertainty, and spatial diversity. To assess current best practices, share methods and data, and identify future research needs for VRE representation in capacity expansion models, four capacity expansion modeling teams from the Electric Power Research Institute, the U.S. Energy Information Administration, the U.S. Environmental Protection Agency, and the National Renewable Energy Laboratory conducted two workshops of VRE modeling for national-scale capacity expansion models. The workshops covered a wide range of VRE topics, including transmission and VRE resource data, VRE capacity value, dispatch and operational modeling, distributed generation, and temporal and spatial resolution. The objectives of the workshops were both to better understand these topics and to improve the representation of VRE across the suite of models. Given these goals, each team incorporated model updates and performed additional analyses between the first and second workshops. This report summarizes the analyses and model 'experiments' that were conducted as part of these workshops as well as the various methods for treating VRE among the four modeling teams. The report also reviews the findings and learnings from the two workshops. We emphasize the areas where there is still need for additional research and development on analysis tools to incorporate VRE into long-term planning and decision-making.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Differentially Variable Component Analysis (dVCA): Identifying Multiple Evoked Components using Trial-to-Trial Variability

Electric potentials and magnetic fields generated by ensembles of synchronously active neurons in response to external stimuli provide information essential to understanding the processes underlying cognitive and sensorimotor activity. Interpreting recordings of these potentials and fields is difficult as each detector records signals simultaneously generated by various regions throughout the brain. We introduce the differentially Variable Component Analysis (dVCA) algorithm, which relies on trial-to-trial variability in response amplitude and latency to identify multiple components. Using simulations we evaluate the importance of response variability to component identification, the robustness of dVCA to noise, and its ability to characterize single-trial data. Finally, we evaluate the technique using visually evoked field potentials recorded at incremental depths across the layers of cortical area VI, in an awake, behaving macaque monkey.

Knuth, Kevin H.↗

Optimization of a GO2/GH2 Swirl Coaxial Injector Element

An injector optimization methodology, method i, is used to investigate optimal design points for a gaseous oxygen/gaseous hydrogen (GO2/GH2) swirl coaxial injector element. The element is optimized in terms of design variables such as fuel pressure drop, DELTA P(sub f), oxidizer pressure drop, DELTA P(sub 0) combustor length, L(sub comb), and full cone swirl angle, theta, for a given mixture ratio and chamber pressure. Dependent variables such as energy release efficiency, ERE, wall heat flux, Q(sub w) injector heat flux, Q(sub inj), relative combustor weight, W(sub rel), and relative injector cost, C(sub rel), are calculated and then correlated with the design variables. An empirical design methodology is used to generate these responses for 180 combinations of input variables. Method i is then used to generate response surfaces for each dependent variable. Desirability functions based on dependent variable constraints are created and used to facilitate development of composite response surfaces representing some, or all, of the five dependent variables in terms of the input variables. Two examples illustrating the utility and flexibility of method i are discussed in detail. First, joint response surfaces are constructed by sequentially adding dependent variables. Optimum designs are identified after addition of each variable and the effect each variable has on the design is shown. This stepwise demonstration also highlights the importance of including variables such as weight and cost early in the design process. Secondly, using the composite response surface that includes all five dependent variables, unequal weights are assigned to emphasize certain variables relative to others. Here, method i is used to enable objective trade studies on design issues such as component life and thrust to weight ratio.

Tucker, P. Kevin↗

Optimization of a GO2/GH2 Impinging Injector Element

An injector optimization methodology, method i, is used to investigate optimal design points for a gaseous oxygen/gaseous hydrogen (GO2/GH2) impinging injector element. The unlike impinging element, a fuel-oxidizer- fuel (F-O-F) triplet, is optimized in terms of design variables such as fuel pressure drop, (Delta)P(sub f), oxidizer pressure drop, (Delta)P(sub o), combustor length, L(sub comb), and impingement half-angle, alpha, for a given mixture ratio and chamber pressure. Dependent variables such as energy release efficiency, ERE, wall heat flux, Q(sub w), injector heat flux, Q(sub inj), relative combustor weight, W(sub rel), and relative injector cost, C(sub rel), are calculated and then correlated with the design variables. An empirical design methodology is used to generate these responses for 163 combinations of input variables. Method i is then used to generate response surfaces for each dependent variable. Desirability functions based on dependent variable constraints are created and used to facilitate development of composite response surfaces representing some, or all, of the five dependent variables in terms of the input variables. Three examples illustrating the utility and flexibility of method i are discussed in detail. First, joint response surfaces are constructed by sequentially adding dependent variables. Optimum designs are identified after addition of each variable and the effect each variable has on the design is shown. This stepwise demonstration also highlights the importance of including variables such as weight and cost early in the design process. Secondly, using the composite response surface which includes all five dependent variables, unequal weights are assigned to emphasize certain variables relative to others. Here, method i is used to enable objective trade studies on design issues such as component life and thrust to weight ratio. Finally, specific variable weights are further increased to illustrate the high marginal cost of realizing the last increment of injector performance and thruster weight.

Tucker, P. Kevin↗

Model Predictive Control-based Optimal Coordination of Distributed Energy Resources

Distributed energy resources, such as renewable energy resources (wind, solar), energy storage and demand response, can be used to complement conventional generators. The uncertainty and variability due to high penetration of wind makes reliable system operations and controls challenging, especially in isolated systems. In this paper, an optimal control strategy is proposed to coordinate energy storage and diesel generators to maximize wind penetration while maintaining system economics and normal operation performance. The goals of the optimization problem are to minimize fuel costs and maximize the utilization of wind while considering equipment life of generators and energy storage. Model predictive control (MPC) is used to solve a look-ahead dispatch optimization problem and the performance is compared to an open loop look-ahead dispatch problem. Simulation studies are performed to demonstrate the efficacy of the closed loop MPC in compensating for uncertainties and variability caused in the system.

Mayhorn, Ebony T.↗

FIND: A Synthetic weather generator to control drought Frequency, Intensity, and Duration

Water systems worldwide are experiencing climate change-induced shifts in drought properties like frequency, intensity, and duration, affecting water security and reliability. To develop and test effective drought preparedness plans, researchers often use synthetic weather generators to create hydrological scenarios that explore drought variability beyond historical records. Existing weather generators typically allow users to adjust streamflow statistics like percentiles or temporal correlation but do not directly control drought properties of frequency, intensity, and duration. To fill this gap, we propose FIND (Frequency, INtensity, and Duration) synthetic weather generator. FIND incorporates a standardized drought index to directly and in dependently control drought frequency, intensity, and duration in generated streamflow time series while preserving observed hydrological variability. Use cases for FIND include i) water systems analysis applications that seek to train and test drought strategies under historical and plausible future drought conditions, and ii) bottom-up vulnerability studies relating system vulnerability outcomes to specific changes in drought properties of frequency, intensity, and duration. Here, we demonstrate FIND’s versatility through three experiments: replicating historically observed drought properties, generating streamflow scenarios for multiple sites preserving correlation between their drought conditions, and generating a set of scenarios with direct and independent changes in drought properties. FIND source code is openly available for applications beyond the scope of this paper.

42 ENGINEERING↗

Baja California Sur Renewable Integration Study

The goal of the Baja California Sur Renewable Integration Study (BAJA-RIS) is to evaluate the potential impacts of increasing penetrations of wind and solar power on Baja California Sur's bulk power system operations. Studying the impact of wind and solar power on power system operations is interesting and challenging because of the variable and uncertain nature of wind and solar resources. Baja California Sur is a very interesting and relevant region to study renewable integration impacts because its power system is an electrical island; most of its electricity is generated by burning expensive imported fossil fuels (oil and diesel), making it the power system in Mexico with the highest electricity variable generation costs and the most polluting; its electricity consumption is expected to grow significantly; and it has significant renewable energy resource potential in terms of wind power and especially in terms of solar power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Commercial and Industrial Base Intermittent Resource Management Pilot

This scoping study summarizes the challenges with integrating wind and solar generation into the California's electricity grid. These challenges include: Smoothing intra-hour variability; - Absorbing excess renewable energy during over-generation periods; - Addressing morning and evening ramping periods. In addition, there are technical challenges to integrating retail demand response (DR) triggered by the wholesale conditions into the CAISO markets. The study describes the DR programs available to the consumers through the utilities in California and CAISO's ancillary services market because an integration of the wholesale and retail DR requires an understanding of these different offerings and the costs associated with acquiring them. Demand-side active and passive storage systems are proposed as technologies that may be used to mitigate the effects of intermittence due to renewable generation. Commercial building technologies as well as industrial facilities with storage capability are identified as targets for the field tests. Two systems used for ancillary services communications are identified as providing the triggers for DR enablement. Through the field tests, issues related to communication, automation and flexibility of demand-side resources will be explored and the performance of technologies that participate in the field tests will be evaluated. The major outcome of this research is identifying and defining flexibility of DR resources and optimized use of these resources to respond to grid conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of Wildfires on Solar Generation, Reserves and Energy Prices

Wildfire seasons in the Western U.S. become more prolonged and intense in recent years bringing significant variability and uncertainty of solar generation. It greatly challenges the bulk power system and electricity market operation managed by California Independent System Operator (CAISO) as California leads both the wildfire records and the solar power integration. This study presents a screening-level analysis of the impact of wildfires on solar generation, operating reserve and energy prices applying historical real-world wildfire and market operation data. To the best of the authors knowledge, it is a first-of-its-kind study and will lay the foundation for market impact quantification and wildfire mitigation strategies design based on projected wildfire activities in future years.

electricity price↗

Carbon-Free Energy: How Much, How Soon?

The scientific consensus is that carbon emissions need to reach net zero by 2050 to stabilize a global temperature rise below 2 degrees C. Many studies have focused on reaching net zero in the power sector by 2050 and have posited the need for clean firm power sources. Resources such as nuclear, fossil generation with carbon capture and sequestration, or other technologies would be needed to complement variable wind and solar generation.

carbon dioxide↗

Existing Methods for Grid Strength Assessment and Role of Hydropower in Future Grids

The power system is undergoing rapid evolution with increasing penetration of inverter-based resources (IBRs), large loads, microgrids, and power electronic devices. Ensuring reliable and stable operation of the modern power grid is a multi-faceted challenge that requires detailed understanding of this complex system. Dynamic stability is a major concern in maintaining the security of power grids as the generation mixes and large loads transitions to include high shares of power electronic devices. The operation of IBRs in regions with low system strength and higher grid impedances has been found to be the main reason behind many of the power system instabilities that manifest themselves in various types of oscillations and interactions that, if not properly addressed and damped, can jeopardize the reliable operation of the power system. Weak grid conditions compound such stability problems, particularly when many IBRs operate in proximity to and connect to weak power grids. Therefore, it is important to assess grid strength for planning, integration and operation of IBRs for a given power system. In this report, we aim to understand and classify existing methodologies for grid strength assessment, along with their limitations and future needs. Further, we aim to utilize the huge untapped potential in utilizing hydro energy resources in addressing some of the pertinent challenges of grid strength and reliable operation of modern power systems. Hydropower, historically valued for its flexibility and dispatchability, now faces new constraints due to reduced share of synchronous machines in the generation mix and seasonal variability of available water resources. Yet, these same plants present untapped potential beyond energy generation - notably, as providers of critical grid services. This report explores how hydropower plants, particularly through operation as synchronous condensers, can play a pivotal role in strengthening the grid amid evolving system dynamics.

13 HYDRO ENERGY↗

Variable stream control engine for advanced supersonic aircraft design update

The updating of the engine concept for a second-generation supersonic transport, the variable stream control engine (VSCE), in terms of mechanical design definition and estimated performance is discussed. The design definition reflects technology advancements that improve system efficiency, durability and environments were established. The components unique to the VSCE concept, a high performance duct burner and a low noise coannular nozzle, and the high temperature components are identified as critical technologies. Technology advances for the high temperature components (main combustor and turbines) are also discussed. To address the requirements in this area, the technical approach for undertaking a high temperature validation program is defined. The multi-phased effort would include assorted rig and laboratory tests, then culminate with the demonstration of a flight-type main combustor and single-stage high pressure turbine at operating conditions envisioned for a VSCE.

Hunt, R. B.↗