Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Origin of the quasi-quantized Hall effect in ZrTe 5

The quantum Hall effect (QHE) is traditionally considered to be a purely two-dimensional (2D) phenomenon. Recently, however, a three-dimensional (3D) version of the QHE was reported in the Dirac semimetal ZrTe 5 . It was proposed to arise from a magnetic-field-driven Fermi surface instability, transforming the original 3D electron system into a stack of 2D sheets. Here, we report thermodynamic, spectroscopic, thermoelectric and charge transport measurements on such ZrTe 5 samples. The measured properties: magnetization, ultrasound propagation, scanning tunneling spectroscopy, and Raman spectroscopy, show no signatures of a Fermi surface instability, consistent with in-field single crystal X-ray diffraction. Instead, a direct comparison of the experimental data with linear response calculations based on an effective 3D Dirac Hamiltonian suggests that the quasi-quantization of the observed Hall response emerges from the interplay of the intrinsic properties of the ZrTe 5 electronic structure and its Dirac-type semi-metallic character.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Open Source Visualization and Analysis Platform for 3D Reconstructions of Materials by Transmission Electron Microscopy

Three-dimensional characterization of materials at the nano- and meso-scale has become possible with transmission and scanning transmission electron microscopes (S/TEM). Its importance has extended to a wide class of nanomaterials such as hydrogen fuel cells, solar cells, industrial catalysts, new battery materials and semiconductor devices, as well as spanning high-tech industry, universities, and national labs. While capable instrumentation is abundant, this rapidly expanding demand for high-resolution tomography is bottlenecked by software that is instead tailored for lower-dose, biological applications and not optimized for higher-resolution materials applications. Existing tomography fails to utilize the chemical information provided by S/TEM spectrometers. To address this problem, this project delivered a scalable, fully functional, freely-distributable, open Source materials tomography package with a modern user interface that enables automated acquisition, alignment, and real-time reconstruction of raw tomography data, and provides advanced segmentation, three-dimensional chemical visualization and analysis optimized for materials applications. It has established an extendable framework capable of automation for high-throughput for the tomography of materials from data acquisition to visualization. Phase I and II delivered a full-featured, cross-platform, clean and integrated application for S/TEM materials tomography. It can read projection data from the microscope, with graphical tools for alignment of data, tomographic reconstruction, segmentation, and visualization of the reconstructed 3D volume. The entire pipeline can be saved to an XML state file, enabling fully reproducible data processing and analysis with a full Python environment for the development of custom algorithms, processing, and analysis requirements. Phase IIB extended the application to provide real-time tomographic reconstruction, "live updates" as data is processed, analysis of big data, and multi-channel tomography. Here, quantitative assessment of nanomaterials can occur as data is being recorded on a 3D visualization platform that accommodates additional information from multiple channels. We provide unmatched high-throughput tomography, where the complete tomographic pipeline from measurement to 3D visualization can occur rapidly. The project was extended to offer capabilities for micro-CT, X-ray, neutron, focused ion beam, atomic electron tomography and atom probe tomography. With over 600 transmission electron microscopes worldwide and approximately 50 coming online each year, the demand and impact of an open-source tomography tool is large. Significant opportunities exist in high-tech industry, universities, and national labs to enable or enhance three-dimensional imaging at the nanoscale and bring automated high-throughput approaches that will accelerate progress in materials characterization and metrology. The project supports a service based business model by enabling lab-specific acquisition and processing customization and integration-support and development that will be provided into Phase III and beyond.

36 MATERIALS SCIENCE↗

Diode-based additive manufacturing of metals using an optically-addressable light valve

We present that Selective Laser Melting (SLM) of metal powder bed layers, whereby 3D metal objects can be printed from a digital file with unprecedented design flexibility, is spurring manufacturing innovations in medical, automotive, aerospace and textile industries. Because SLM is based on raster-scanning a laser beam over each layer, the process is relatively slow compared to most traditional manufacturing methods (hours to days), thus limiting wider spread use. Here we demonstrate the use of a large area, photolithographic method for 3D metal printing, using an optically-addressable light valve (OALV) as the photomask, to print entire layers of metal powder at once. An optical sheet of multiplexed ~5 kW, 20 ms laser diode and ~1 MW, 7 ns Q-switched laser pulses are used to selectively melt each layer. Finally, the patterning of near infrared light is accomplished by imaging 470 nm light onto the transmissive OALV, which consists of polarization-selective nematic liquid crystal sandwiched between a photoconductor and transparent conductor for switching.

36 MATERIALS SCIENCE↗

Controlled synthesis of three-dimensional hierarchical Bi{sub 2}WO{sub 6} microspheres with optimum photocatalytic activity

Highlights: Black-Right-Pointing-Pointer The synthesized method is very simple. It can be widely used in the production. Black-Right-Pointing-Pointer The morphology is novel and the property is fine. Black-Right-Pointing-Pointer The formation of 3D hierarchical microsphere can be induced by changing the concentration of KNO{sub 3}. -- Abstract: Three-dimensional (3D) hierarchical Bi{sub 2}WO{sub 6} microsphere and octahedral Bi{sub 2}WO{sub 6} have been synthesized by a facile hydrothermal method using KNO{sub 3} solution and distilled water as solvent, respectively. The obtained products were characterized by X-ray diffraction, scanning electron microscopy, N{sub 2} adsorption/desorption, and UV-vis diffuse reflectance spectroscopy in detail. The concentration of KNO{sub 3} played a key role in the formation of 3D hierarchical Bi{sub 2}WO{sub 6} microspheres. A possible formation mechanism of Bi{sub 2}WO{sub 6} microsphere was proposed. The photocatalytic activity of the as-synthesized products was evaluated by monitoring the degradation of MB solution under sunlight irradiation. It was found that the photocatalytic activity of the 3D hierarchical Bi{sub 2}WO{sub 6} microsphere was superior to the octahedral Bi{sub 2}WO{sub 6}, which was attributed to the larger surface area and special hierarchical structure of Bi{sub 2}WO{sub 6} microsphere.

36 MATERIALS SCIENCE↗

Scanning photoelectron microscope for nanoscale three-dimensional spatial-resolved electron spectroscopy for chemical analysis

In order to achieve nondestructive observation of the three-dimensional spatially resolved electronic structure of solids, we have developed a scanning photoelectron microscope system with the capability of depth profiling in electron spectroscopy for chemical analysis (ESCA). We call this system 3D nano-ESCA. For focusing the x-ray, a Fresnel zone plate with a diameter of 200 {mu}m and an outermost zone width of 35 nm is used. In order to obtain the angular dependence of the photoelectron spectra for the depth-profile analysis without rotating the sample, we adopted a modified VG Scienta R3000 analyzer with an acceptance angle of 60 deg. as a high-resolution angle-resolved electron spectrometer. The system has been installed at the University-of-Tokyo Materials Science Outstation beamline, BL07LSU, at SPring-8. From the results of the line-scan profiles of the poly-Si/high-k gate patterns, we achieved a total spatial resolution better than 70 nm. The capability of our system for pinpoint depth-profile analysis and high-resolution chemical state analysis is demonstrated.

36 MATERIALS SCIENCE↗

SU-F-E-13: Design and Fabrication of Gynacological Brachytherapy Shielding & Non Shielding Applicators Using Indigenously Developed 3D Printing Machine

Purpose: In this innovative work we have developed Gynecological Brachytherapy shielding & Non Shielding Applicators and compared with the commercially available applicators by using the indigenously developed 3D Printing machine. Methods: We have successfully indigenously developed the 3D printing machine. Which contain the 3 dimensional motion platform, Heater unit, base plate, ect… To fabricate the Gynecological Brachytherapy shielding & non shielding applicators the 3D design were developed in the computer as virtual design. This virtual design is made in a CAD computer file using a 3D modeling program. Separate programme for the shielding & non shielding applicators. We have also provided the extra catheter insert provision in the applicator for the multiple catheter. The DICOM file of the applicator were then converted to stereo Lithography file for the 3D printer. The shielding & Non Shielding Applicators were printed on a indigenously developed 3D printer material. The same dimensions were used to develop the applicators in the acrylic material also for the comparative study. A CT scan was performed to establish an infill-density calibration curve as well as characterize the quality of the print such as uniformity and the infill pattern. To commission the process, basic CT and dose properties of the printing materials were measured in photon beams and compared against water and soft tissue. Applicator were then scanned to confirm the placement of multiple catheter position. Finally dose distributions with rescanned CTs were compared with those computer-generated applicators. Results: The doses measured from the ion Chamber and X-Omat film test were within 2%. The shielded applicator reduce the rectal dose comparatively with the non shielded applicator. Conclusion: As of submission 3 unique cylinders have been designed, printed, and tested dosimetrically. A standardizable workflow for commissioning custom 3D printed applicators was codified and will be reported.

60 APPLIED LIFE SCIENCES↗

SU-E-T-455: Characterization of 3D Printed Materials for Proton Beam Therapy

Purpose: The widespread availability of low cost 3D printing technologies provides an alternative fabrication method for customized proton range modifying accessories such as compensators and boluses. However the material properties of the printed object are dependent on the printing technology used. In order to facilitate the application of 3D printing in proton therapy, this study investigated the stopping power of several printed materials using both proton pencil beam measurements and Monte Carlo simulations. Methods: Five 3–4 cm cubes fabricated using three 3D printing technologies (selective laser sintering, fused-deposition modeling and stereolithography) from five printers were investigated. The cubes were scanned on a CT scanner and the depth dose curves for a mono-energetic pencil beam passing through the material were measured using a large parallel plate ion chamber in a water tank. Each cube was measured from two directions (perpendicular and parallel to printing plane) to evaluate the effects of the anisotropic material layout. The results were compared with GEANT4 Monte Carlo simulation using the manufacturer specified material density and chemical composition data. Results: Compared with water, the differences from the range pull back by the printed blocks varied and corresponded well with the material CT Hounsfield unit. The measurement results were in agreement with Monte Carlo simulation. However, depending on the technology, inhomogeneity existed in the printed cubes evidenced from CT images. The effect of such inhomogeneity on the proton beam is to be investigated. Conclusion: Printed blocks by three different 3D printing technologies were characterized for proton beam with measurements and Monte Carlo simulation. The effects of the printing technologies in proton range and stopping power were studied. The derived results can be applied when specific devices are used in proton radiotherapy.

07 ISOTOPE AND RADIATION SOURCES↗

Image Reconstruction from Sparse-view Data Acquired with Portable X-ray Devices

• Portable X-ray systems enable on-site 3D imaging for non-invasive inspection of suspicious packages and explosives. • Existing reconstruction algorithms (e.g., FDK or Feldkamp, Davis and Kress) require hundreds of projections over 360 degrees. • Sparse-view scan reduces scanning time and setup effort, making it ideal for field use in timecritical scenarios. • Existing reconstruction algorithms introduce severe artifacts when applied to sparse-view data. • We developed a total variation (TV)-based optimization algorithm for yielding 3D images from sparse-view data collected with our portable X-ray imaging system.

Xia, Dan [University of Chicago, Chicago, IL]↗

Real-time microstructure imaging by Laue microdiffraction: A sample application in laser 3D printed Ni-based superalloys

Synchrotron-based Laue microdiffraction has been widely applied to characterize the local crystal structure, orientation, and defects of inhomogeneous polycrystalline solids by raster scanning them under a micro/nano focused polychromatic X-ray probe. In a typical experiment, a large number of Laue diffraction patterns are collected, requiring novel data reduction and analysis approaches, especially for researchers who do not have access to fast parallel computing capabilities. In this article, a novel approach is developed by plotting the distributions of the average recorded intensity and the average filtered intensity of the Laue patterns. Visualization of the characteristic microstructural features is realized in real time during data collection. As an example, this method is applied to image key features such as microcracks, carbides, heat affected zone, and dendrites in a laser assisted 3D printed Ni-based superalloy, at a speed much faster than data collection. Such analytical approach remains valid for a wide range of crystalline solids, and therefore extends the application range of the Laue microdiffraction technique to problems where real-time decision-making during experiment is crucial (for instance time-resolved non-reversible experiments).

36 MATERIALS SCIENCE↗

Technical Note: Development of a 3D printed subresolution sandwich phantom for validation of brain SPECT analysis

Purpose: To make an adaptable, head shaped radionuclide phantom to simulate molecular imaging of the brain using clinical acquisition and reconstruction protocols. This will allow the characterization and correction of scanner characteristics, and improve the accuracy of clinical image analysis, including the application of databases of normal subjects. Methods: A fused deposition modeling 3D printer was used to create a head shaped phantom made up of transaxial slabs, derived from a simulated MRI dataset. The attenuation of the printed polylactide (PLA), measured by means of the Hounsfield unit on CT scanning, was set to match that of the brain by adjusting the proportion of plastic filament and air (fill ratio). Transmission measurements were made to verify the attenuation of the printed slabs. The radionuclide distribution within the phantom was created by adding {sup 99m}Tc pertechnetate to the ink cartridge of a paper printer and printing images of gray and white matter anatomy, segmented from the same MRI data. The complete subresolution sandwich phantom was assembled from alternate 3D printed slabs and radioactive paper sheets, and then imaged on a dual headed gamma camera to simulate an HMPAO SPECT scan. Results: Reconstructions of phantom scans successfully used automated ellipse fitting to apply attenuation correction. This removed the variability inherent in manual application of attenuation correction and registration inherent in existing cylindrical phantom designs. The resulting images were assessed visually and by count profiles and found to be similar to those from an existing elliptical PMMA phantom. Conclusions: The authors have demonstrated the ability to create physically realistic HMPAO SPECT simulations using a novel head-shaped 3D printed subresolution sandwich method phantom. The phantom can be used to validate all neurological SPECT imaging applications. A simple modification of the phantom design to use thinner slabs would make it suitable for use in PET.

60 APPLIED LIFE SCIENCES↗

Tomography Analysis of Orion Artemis 1 Heatshield Sample

The Orion spacecraft, under NASA's Artemis program, is an integral step in humanity's ambitions of deep space exploration, including our return to the Moon and subsequent mission to Mars. The performance of Orion's heatshield is central to ensuring the safety and success of such missions. This presentation offers a comprehensive overview of the process used in and findings derived from tomography scans of an Artemis 1 heatshield sample executed at the Lawrence Berkeley National Laboratory's Advanced Light Source. These tomography scans captured high-resolution X-Ray images of the heatshield's microstructure, allowing advanced imaging to be employed for 3D image segmentation and visualization of the sample. The Porous Media Analysis (PuMA) software stands central to our analysis, offering robust computational algorithms and methodologies to digitally compute properties of the heatshield material. The presentation discusses the following derived metrics: - Volume fractions, representing the spatial distribution and amounts of various components throughout the heatshield’s depth. - Porosity and crack distributions, offering insights into the void space within the material, critical for understanding the heatshield's structural integrity. - Fiber orientation, detailing the alignment and arrangement of fibers, significant for material orthotropy. - Permeability estimates, quantifying the passage of gas through the material, relevant for re-entry conditions and pyrolysis gasses. One distinctive feature of this study is the comparative evaluation against data obtained from tomography scans of the Exploration Flight Test-1 (EFT-1) heatshield. Such a comparison offers multiple insights, including evaluation of the consistency and repeatability of manufacturing processes as well as understanding of any evolutionary changes in heatshield design or material properties.

Micro-tomography↗

Deformation and damage of sintered low-porosity aluminum under planar impact: microstructures and mechanisms

In this paper, plate impact experiments are conducted to study compaction and spallation of 5% porosity aluminum. Free surface velocity histories, the Hugoniot elastic limit (HEL), and spall strengths are obtained at different peak stresses and pulse durations. Scanning electron microscopy, electron backscatter diffraction, and X-ray computed tomography are used to characterize 2D and 3D microstructures. 3D void topology analyses yield rich information on size distribution, shape, orientation, and connectivity of voids. HEL decreases/increases with sample thickness/impact velocity and approaches saturation. Its tensile strength increases with increasing peak stress and shock-induced densification. With the enhanced compaction under increasing impact velocities, spall damage modes change from growth of original voids to inter-particle crack propagation and to “random” nucleation of new voids. Such a change in damage mechanism also gives rise to a distinct decrease in damage extent at high impact velocities. Finally, compaction induces strain localizations around the original voids, while subsequent tension results in grain refinement, and shear deformation zones between staggered cracks.

36 MATERIALS SCIENCE↗

Probing Heterogeneity in Bovine Enamel Composition through Nanoscale Chemical Imaging using Atom Probe Tomography

Objective: The aim of this study was to determine the heterogeneity in chemical composition of bovine enamel using atom probe tomography, and thereby evaluate the suitability of bovine enamel as a substitute for human enamel in in vitro dental research. Design: Enamel samples from extracted bovine incisor teeth were first sectioned using a diamond saw and then milled into needle-like samples (<100 nm diameter) by focused ion beam (FIB) coupled with a scanning electron microscope (SEM). The samples were then analyzed in the atom probe to acquire three-dimensional (3D) images and quantify the atomic chemistry and distribution in bovine enamel. Results: For the first time, the atomic-level composition and clustering of major constituents and impurities within bovine enamel were determined and imaged. We discovered that the chemical composition of bovine enamel is spatially inhomogeneous at the atomic scale. The average bulk Ca/P ratio, ~1.4, was in agreement with previously reported literature values from alternative conventional methods. When assessed locally at the atomic scale, the Ca/P ratio varied between 1.1 and 2.03. We also discovered that the Mg impurities were significantly segregated throughout the enamel, and such clustering influenced the variation of Ca/P ratios. The increase in Mg concentrations, near the Mg clusters, correlated with increased Ca and decreased P concentrations. Conclusion: In conclusion, the presented findings of variability in local composition should be taken into account when interpreting dental research results from bovine enamel.

59 BASIC BIOLOGICAL SCIENCES↗

High-RRR thin-films of NB produced using energetic condensation from a coaxial, rotating vacuum ARC plasma (CEDTM)

We have recently demonstrated unprecedentedly high values of RRR (up to 542) in thin-films of pure Nb deposited on a-plane sapphire and MgO crystal substrates. The Nb films were grown using a vacuum arc discharge struck between a reactor grade Nb cathode rod (RRR {approx} 30) and a coaxial, semi-transparent Mo mesh anode, with a heated substrate placed just outside it. The substrates were pre-heated for several hours prior to deposition at different temperatures. Low pre-heat temperatures (<300 C) and deposition temperatures (<300 C) give low RRR (<50) films, whereas higher pre-heat (700 C) and coating temperatures (500 C) give RRR=214 on a-sapphire and RRR=542 on MgO. XRD (Bragg-Brentano scans and Pole Figures), EBSD and SIMS data reveal several features: (1) on asapphire, higher temperatures show better 3D registry for epitaxial growth of Nb; the crystal structure evolves from textured, polycrystalline (with twins) to single-crystal; (2) on MgO, there is a transition from {l_brace}110{r_brace} planes to {l_brace}100{r_brace} as the temperature is increased beyond 500 C. The dramatic increase in RRR (from {approx}10 at <300 C to {approx}500 at >600 C) is correlated with better epitaxial crystal structure in both a-sapphire and MgO substrate grown films. However, the SIMS data reveal that the most important requirement for high-RRR Nb films on either substrate is the reduction of impurities in the film, especially hydrogen. The hydrogen content in the MgO grown films is 1000 times lower than in bulk Nb tested as a reference from SRF cavity grade Nb. This result has potential implications for SRF accelerators. Coating bulk Nb cavities with an MgO layer followed by our CEDTM deposited Nb films, might create superior SRF cavities that would avoid Q-slope and operate at higher peak fields.

08 HYDROGEN↗

Regularization approach for tomosynthesis X-ray inspection

X-ray inspection is intended to be used as an escalation technique for inspection of carbon fiber reinforced plastics (CFRP) in aerospace applications, especially in case of unclear indications from ultrasonic or other NDT modalities. Due to their large dimensions, most aerospace components cannot be scanned by conventional computed tomography. In such cases, X-ray Laminography may be applied, allowing a pseudo 3D slice-by-slice reconstruction of the sample with Tomosynthesis. However, due to the limited angle acquisition geometry, reconstruction artifacts arise, especially at surfaces parallel to the imaging plane. To regularize the Tomosynthesis approach, we propose an additional prescan of the object to detect outer sample surfaces. We recommend the use of contrasted markers which are temporarily attached to the sample surfaces. The depth position of the markers is then derived from that prescan. As long as the sample surface remains simple, few markers are required to fit the respective object surfaces. The knowledge about this surface may then be used to regularize the final Tomosynthesis reconstruction, performed with markerless projections. Eventually, it can also serve as prior information for an ART reconstruction or to register a CAD model of the sample. The presented work is carried out within the European FP7 project QUICOM. We demonstrate the proposed approach within a simulation study applying an acquisition geometry suited for CFRP part inspection. A practical verification of the approach is planned later in the project.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coherent electronic-vibrational dynamics in deuterium bromide probed via attosecond transient-absorption spectroscopy

Ultrafast laser excitation can trigger multiplex coherent dynamics in molecules. Here, we report attosecond transient-absorption experiments addressing simultaneous probing of electronic and vibrational dynamics in a prototype molecule, deuterium bromide (DBr), following its strong-field ionization. Electronic and vibrational coherences in the ionic X$^2\Pi_{3/2}$ and X$^2\Pi_{1/2}$ states are characterized in the Br-$3d$ core-level absorption spectra via quantum beats with 12.6-fs and 19.9-fs periodicities, respectively. Polarization scans reveal that the phase of the electronic quantum beats depends on the probe direction, experimentally showing that the coherent electronic motion corresponds to the oscillation of the hole density along the ionization-field direction. The vibrational quantum beats are found to maintain a relatively constant amplitude, whereas the electronic quantum beats exhibit a partial decrease in time. Quantum wave-packet simulations show that the decoherence effect from the vibrational motion is insignificant because of the parallel relation between the X$^2\Pi_{3/2}$ and X$^2\Pi_{1/2}$ potentials. Finally, a comparison between the DBr and HBr results suggests that rotation motion is responsible for the decoherence since it leads to initial alignment prepared by the strong-field ionization.

74 ATOMIC AND MOLECULAR PHYSICS↗

MO-FG-CAMPUS-TeP1-04: Pseudo-In-Vivo Dose Verification of a New Mono-Isocentric Technique for the Treatment of Multiple Brain Metastases

Purpose: To validate dose calculation and delivery accuracy of a recently introduced mono-isocentric technique for the treatment of multiple brain metastases in a realistic clinical case. Methods: Anonymized CT scans of a patient were used to model a hollow phantom that duplicates anatomy of the skull. A 3D printer was used to construct the phantom of a radiologically bone-equivalent material. The hollow phantom was subsequently filled with a polymer gel 3D dosimeter which also acted as a water-equivalent material. Irradiation plan consisted of 5 targets and was identical to the one delivered to the specific patient except for the prescription dose which was optimized to match the gel dose-response characteristics. Dose delivery was performed using a single setup isocenter dynamic conformal arcs technique. Gel dose read-out was carried out by a 1.5 T MRI scanner. All steps of the corresponding patient’s treatment protocol were strictly followed providing an end-to-end quality assurance test. Pseudo-in-vivo measured 3D dose distribution and calculated one were compared in terms of spatial agreement, dose profiles, 3D gamma indices (5%/2mm, 20% dose threshold), DVHs and DVH metrics. Results: MR-identified polymerized areas and calculated high dose regions were found to agree within 1.5 mm for all targets, taking into account all sources of spatial uncertainties involved (i.e., set-up errors, MR-related geometric distortions and registration inaccuracies). Good dosimetric agreement was observed in the vast majority of the examined profiles. 3D gamma index passing rate reached 91%. DVH and corresponding metrics comparison resulted in a satisfying agreement between measured and calculated datasets within targets and selected organs-at-risk. Conclusion: A novel, pseudo-in-vivo QA test was implemented to validate spatial and dosimetric accuracy in treatment of multiple metastases. End-to-end testing demonstrated that our gel dosimetry phantom is suited for such QA procedures, allowing for 3D analysis of both targeting placement and dose.

60 APPLIED LIFE SCIENCES↗

Nanoparticle-enhanced absorptivity of copper during laser powder bed fusion

We report laser powder bed fusion (LPBF) of pure copper for thermal and electrical applications is hampered by its low near-infrared absorptivity and high thermal diffusivity. These material properties make it very difficult to localize the thermal energy needed to produce high density 3D printed parts. Modification of metal powders via nanoparticle additives is a promising approach to increasing absorptivity, but the effect of nanoparticles on absorptivity and melting behavior during LPBF is not well understood. In this study, we developed an in situ calorimetry system to measure effective absorptivity during LPBF on copper substrates. We decorated copper substrates using three nanoparticle systems (CuS, TiB 2 , multilayer graphene flakes) and demonstrated an enhanced absorptivity of the decorated substrates relative to pure copper. Graphene nanoflakes resulted in the highest improved absorption relative to pure copper from 0.09 to 0.48, due to their stability at high laser scanning powers. A thermomechanical model with convective heat transfer provided confidence in the measurements by reproducing the experimental melt pool traces. Full 3D cylindrical prints demonstrated an improvement in relative density of the copper-graphene powder prints (in the range of 0.930–0.992), relative to that of as-purchased copper powder prints (in the range of 0.854–0.972). This work provides a fundamental study of nanoparticle-enabled LPBF of highly reflective metals and demonstrates a viable route for expanding the library of reliably printable metals.

36 MATERIALS SCIENCE↗