Search NASA⌕ Search

SEARCH · Search NASA

Results for “APPLIANCES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Transactive Home Energy Management Systems: The Impact of Their Proliferation on the Electric Grid

Approximately 100 million singlefamily homes in the United States account for 36% of the electricity load, and often they determine the peak system load, especially on hot summer days when residential air-conditioning use is high. Traditional building power profiles are changing. Currently, there is an increased use of energy-efficient building materials and designs, which decreases building loads. In addition, there is an increased adoption of rooftop solar photovoltaic (PV), which leads to bidirectional power flow and significant power ramps as PV output decreases in the late afternoon. Building power profiles are likely to change even more as residential energy storage products proliferate. Therefore, a better understanding of residential electricity demand is key to addressing the envisioned transition of the electric power system from its traditional structure to one that is transactive.

25 ENERGY STORAGE↗

Data-based Aggregate Model of Refrigerators for Electric Power Grid Services

Electrical power system stability under high penetration of intermittent renewable energy generation, such as wind and solar energy, has become a high concern. It is unpredictable and hard to control due to little inertial behavior characteristic to these generation resources. To help mitigate possibly undesirable frequency excursions, demand-side frequency control presents an emerging solution. By observing the frequency deviation, devices could switch operating modes for a short time to rebalance generation. To analyze device level control algorithms, aggregate models for their behavior are needed. Refrigerators are household devices that could help with load modulation. This paper uses real measured data to analyze the refrigerator behavior, learn about its operating mode and power consumption ranges. A Markov chain process is proposed to model the transition of a refrigerator population from one operating mode to another, such that the overall load is modulated according to the control input. The Markov-chain model can be used to design control so that the overall load is modulated according to the control input.

Markov chain model, demand response, refrigerator,↗

Energetic Potential for Demand Response in Detached Single Family Homes in Austin, TX

This study builds a generalized tool to quantify the maximum peak load reduction achievable with residential demand response and distributed energy resources (DERs). The tool is demonstrated by using empirical energy usage data from detached single family households within the service territory of Austin Energy - the local municipal utility in Austin, TX. The demand response optimization algorithm shifts energy usage of four controllable, high-consumption residential devices to off-peak hours: HVAC (heating, ventilation, and air conditioning) systems, electric water heaters, electric vehicles, and pool pumps. In addition, rooftop solar generation on individual residences is considered to reduce net load to the utility, and an energy storage system optimization model performing energy arbitrage further reduces peak demand. Results from the aggregate demand response and battery optimization study indicate that peak demand for the 2017 summer peak in Austin Energy could have been reduced by 26 MW or 2.9%. Here, by considering the combined effect of controllable consumer loads, solar generation, and energy storage systems, this study highlights the potential of strategic demand response and energy arbitrage to reduce peak demand at the distribution level.

14 SOLAR ENERGY↗

Non-Intrusive Energy Disaggregation Using Non-Negative Matrix Factorization With Sum-to-k Constraint

Energy disaggregation or non-intrusive load monitoring addresses the issue of extracting device-level energy consumption information by monitoring the aggregated signal at one single measurement point without installing meters on each individual device. Energy disaggregation can be formulated as a source separation problem, where the aggregated signal is expressed as linear combination of basis vectors in a matrix factorization framework. In this paper, an approach based on Sum-to-k constrained non-negative matrix factorization (S2K-NMF) is proposed. By imposing the sum-to-k constraint and the non-negative constraint, S2K-NMF is able to effectively extract perceptually meaningful sources from complex mixtures. The strength of the proposed algorithm is demonstrated through two sets of experiments: Energy disaggregation in a residential smart home; and heating, ventilating, and air conditioning components energy monitoring in an industrial building testbed maintained at the Oak Ridge National Laboratory. Furthermore, extensive experimental results demonstrate the superior performance of S2K-NMF as compared to state-of-the-art decomposition-based disaggregation algorithms.

42 ENGINEERING↗

An Evaluation of the HVAC Load Potential for Providing Load Balancing Service

This paper investigates the potential of providing aggregated intra-hour load balancing services using heating, ventilating, and air-conditioning (HVAC) systems. A direct-load control algorithm is presented. A temperature-priority-list method is used to dispatch the HVAC loads optimally to maintain consumer-desired indoor temperatures and load diversity. Realistic intra-hour load balancing signals were used to evaluate the operational characteristics of the HVAC load under different outdoor temperature profiles and different indoor temperature settings. The number of HVAC units needed is also investigated. Modeling results suggest that the number of HVACs needed to provide a {+-}1-MW load balancing service 24 hours a day varies significantly with baseline settings, high and low temperature settings, and the outdoor temperatures. The results demonstrate that the intra-hour load balancing service provided by HVAC loads meet the performance requirements and can become a major source of revenue for load-serving entities where the smart grid infrastructure enables direct load control over the HAVC loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Local Communication in Populations of Thermostatically Controlled Loads

Thermostatically controlled loads (TCLs) have shown great potential for demand response (DR) in electric grid operations. However, it has been commonly seen that DR events using TCLs may cause load synchronization and unwanted oscillatory effects, especially in homogeneous populations. In an attempt to mitigate the negative impacts of DR events, a decentralized method is proposed that modifies each thermostat behavior based on the activity of a small number of nearby TCLs. This feedback introduces the possibility of instability in the aggregate behavior. A stability analysis is performed on a linearized model of the aggregate system and the results of that analysis compared to simulation results. The proposed modification of thermostat behavior results in fourfold reduction in the post-DR peak while suppressing ensuing oscillations at the expense of a modest increase in compressor cycling. Further, the linearized model also provides insight into the aggregate behavior of the population.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Endoluminal ultrasound applicators for MR-guided thermal ablation of pancreatic tumors: Preliminary design and evaluation in a porcine pancreas model

Purpose: Endoluminal ultrasound may serve as a minimally invasive option for delivering thermal ablation to pancreatic tumors adjacent to the stomach or duodenum. The objective of this study was to explore the basic feasibility of this treatment strategy through the design, characterization, and evaluation of proof-of-concept endoluminal ultrasound applicators capable of placement in the gastrointestinal (GI) lumen for volumetric pancreas ablation under MR guidance. Methods: Two variants of the endoluminal applicator, each containing a distinct array of two independently powered transducers (10 × 10 mm 3.2 MHz planar; or 8 × 10 × 20 mm radius of curvature 3.3 MHz curvilinear geometries) at the distal end of a meter long flexible catheter assembly, were designed and fabricated. Transducers and circulatory water flow for acoustic coupling and luminal cooling were contained by a low-profile polyester balloon covering the transducer assembly fixture. Each applicator incorporated miniature spiral MR coils and mechanical features (guiding tips and hinges) to facilitate tracking and insertion through the GI tract under MRI guidance. Acoustic characterization of each device was performed using radiation force balance and hydrophone measurements. Device delivery into the upper GI tract, adjacent to the pancreas, and heating characteristics for treatment of pancreatic tissue were evaluated in MR-guided ex vivo and in vivo porcine experiments. MR guidance was utilized for anatomical target identification, tracking/positioning of the applicator, and MR temperature imaging (MRTI) for PRF-based multislice thermometry, implemented in the real-time RTHawk software environment. Results: Force balance and hydrophone measurements indicated efficiencies of 48.8% and 47.8% and −3 dB intensity beam-widths of 3.2 and 1.2 mm for the planar and curvilinear transducers, respectively. Ex vivo studies on whole-porcine carcasses revealed capabilities of producing ablative temperature rise (ΔT > 15 °C) contours in pancreatic tissue 4–40 mm long and 4–28 mm wide for the planar transducer applicator (1–13 min sonication duration, ∼4 W/cm{sup 2} applied acoustic intensity). Curvilinear transducers produced more selective heating, with a narrower ΔT > 15 °C contour length and width of up to 1–24 mm and 2–7 mm, respectively (1–7 min sonication duration, ∼4 W/cm{sup 2} applied acoustic intensity). Active tracking of the miniature spiral coils was achieved using a Hadamard encoding tracking sequence, enabling real-time determination of each coil’s coordinates and automated prescription of imaging planes for thermometry. In vivo MRTI-guided heating trials in three pigs demonstrated capability of ∼20 °C temperature elevation in pancreatic tissue at 2 cm depths from the applicator, with 5–7 W/cm{sup 2} applied intensity and 6–16 min sonication duration. Dimensions of thermal lesions in the pancreas ranged from 12 to 28 mm, 3 to 10 mm, and 5 to 10 mm in length, width, and depth, respectively, as verified through histological analysis of tissue sections. Multiple-baseline reconstruction and respiratory-gated acquisition were demonstrated to be effective strategies in suppressing motion artifacts for clear evolution of temperature profiles during MRTI in the in vivo studies. Conclusions: This study demonstrates the technical feasibility of generating volumetric ablation in pancreatic tissue using endoluminal ultrasound applicators positioned in the stomach lumen. MR guidance facilitates target identification, device tracking/positioning, and treatment monitoring through real-time multislice PRF-based thermometry.

60 APPLIED LIFE SCIENCES↗

On the development of the quantitative texture analysis and its application in solving problems of the Earth sciences

A history of texture analysis (TA) evolution is shown, beginning from the first experimental and theoretical attempts to find and characterize preferred orientations of crystal lattices of grains in real polycrystalline samples. Stages of formation of TA theoretical apparatus, its basic elements, and also application of its capabilities for quantitatively describing anisotropic properties of textured samples are discussed. Attention is also paid to the limitations and difficulties associated with the analysis. The application of the quantitative TA apparatus is demonstrated by example describing elastic properties of textured materials up to multiphase samples containing pores and cracks. A wide scope of TA includes the analysis based on neutron scattering which has been effectively developed at the Frank Laboratory of Neutron Physics. A practical opportunity to determine the bulk crystallographic textures of single-phase and multiphase materials is offered by the use of modern neutron diffractometers, including the SKAT diffractometer at the IBR-2 pulsed reactor. This is especially important for studying samples of natural rocks. The examples given show how the neutron scattering data for the quantitative TA are used in combination with other physical and petrological methods for solving fundamental problems of geology and geophysics based on the analysis of a structure and properties of the Earth’s lithosphere matter. The review includes a detailed list of references of original works concerning the TA elaboration, overview publications and monographs, and also information on the most popular TA-related software.

36 MATERIALS SCIENCE↗

Frequency Regulation Services from Connected Residential Devices: Short Paper

In this paper, we demonstrate the potential benefits that residential buildings can provide for frequency regulation services in the electric power grid. In a hardware-in-the- loop (HIL) implementation, simulated homes along with a physical laboratory home are coordinated via a grid aggregator, and it is shown that their aggregate response has the potential to follow the regulation signal on a timescale of seconds. Connected (communication-enabled), devices in the National Renewable Energy Laboratory's (NREL's) Energy Systems Integration Facility (ESIF) received demand response (DR) requests from a grid aggregator, and the devices responded accordingly to meet the signal while satisfying user comfort bounds and physical hardware limitations. Future research will address the issues of cybersecurity threats, participation rates, and reducing equipment wear-and-tear while providing grid services.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Report on accelerated corrosion studies.

Sandia National Laboratories (SNL) conducted accelerated atmospheric corrosion testing for the U.S. Consumer Product Safety Commission (CPSC) to help further the understanding of the development of corrosion products on conductor materials in household electrical components exposed to environmental conditions representative of homes constructed with problem drywall. The conditions of the accelerated testing were chosen to produce corrosion product growth that would be consistent with long-term exposure to environments containing humidity and parts per billion (ppb) levels of hydrogen sulfide (H{sub 2}S) that are thought to have been the source of corrosion in electrical components from affected homes. This report documents the test set-up, monitoring of electrical performance of powered electrical components during the exposure, and the materials characterization conducted on wires, screws, and contact plates from selected electrical components. No degradation in electrical performance (measured via voltage drop) was measured during the course of the 8-week exposure, which was approximately equivalent to 40 years of exposure in a light industrial environment. Analyses show that corrosion products consisting of various phases of copper sulfide, copper sulfate, and copper oxide are found on exposed surfaces of the conductor materials including wires, screws, and contact plates. The morphology and the thickness of the corrosion products showed a range of character. In some of the copper wires that were observed, corrosion product had flaked or spalled off the surface, exposing fresh metal to the reaction with the contaminant gasses; however, there was no significant change in the wire cross-sectional area.

36 MATERIALS SCIENCE↗

Business Case for Energy Efficiency in Support of Climate Change Mitigation, Economic and Societal Benefits in the United States

This study seeks to provide policymakers and other stakeholders with actionable information towards a road map for reducing energy consumption in the most cost-effective way. A major difference between the current study and some others is that we focus on individual equipment types that might be the subject of policies - such as labels, energy performance standards, and incentives - to affect market transformation in the short term, and on high-efficiency technology options that are available today. The approach of the study is to assess the impact of short-term actions on long-term impacts. “Short term” market transformation is assumed to occur by 2015, while “long-term” energy demand reduction impacts are assessed in 2030. In the intervening years, most but not all of the equipment studied will turn over completely. The 15-year time frame is significant for many products however, indicating that delay of implementation postpones impacts such as net economic savings and mitigation of emissions of carbon dioxide. Such delays would result in putting in place energy-wasting technologies, postponing improvement until the end of their service life, or potentially resulting in expensive investment either in additional energy supplies or in early replacement to achieve future energy or emissions reduction targets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗