Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerating cavity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

Active Q-Switched X-Ray Regenerative Amplifier Free-Electron Laser

Despite tremendous progress in x-ray free-electron laser (FEL) science over the last decade, future applications still demand fully coherent, stable x-rays that have not been demonstrated in existing X-ray FEL facilities. Here in this Letter, we describe an active Q-switched x-ray regenerative amplifier FEL scheme to produce fully coherent, high-brightness, hard x rays at a high-repetition rate. By using simple electron-beam phase space manipulation, we show this scheme is flexible in controlling the x-ray cavity quality factor Q and hence the output radiation. We report both theoretical and numerical studies on this scheme with a wide range of accelerator, x-ray cavity, and undulator parameters.

47 OTHER INSTRUMENTATION↗

Simulation of Conduction Cooled SRF Cavity

SRF cavities are used heavily in high energy physics research, but the operational complexities of SRF cavities prevent their widespread use in industry. One notable complexity of operating an SRF cavity is liquid helium coolant, and replacing liquid helium with cryocooler conduction cooling is an important research and development interest. As part of this effort, a system consisting of a 650 MHz single cell cavity, a commercial grade pulse tube refrigerator, and a thermal conduction link was simulated through finite element analysis. The electromagnetic fields inside the cavity, heat flow through the system, and temperature distribution of the thermal link and cavity were calculated. Based on the simulation, we found that a 2 W @ 4.2 K pulse tube refrigerator is capable of cooling a single cell Nb 3 Sn coated cavity operating at up to 12 MV/m accelerating gradient. The maximum simulated temperature of the cavity was below 7 K, and the thermal conduction link was shown to significantly attenuate the cryocooler thermal oscillations at the location of the cavity

43 PARTICLE ACCELERATORS↗

Recirculating Linear Accelerators for Future Muon Facilities

Neutrino Factories (NF) and Muon Colliders (MC) require rapid acceleration of short-lived muons to multi-GeV and TeV energies. A Recirculating Linear Accelerator (RLA) that uses superconducting RF structures can provide exceptionally fast and economical acceleration to the extent that the focusing range of the RLA quadrupoles allows each muon to pass several times through each high-gradient cavity. A new concept of rapidly changing the strength of the RLA focusing quadrupoles as the muons gain energy is being developed to increase the number of passes that each muon will make in the RF cavities, leading to greater cost effectiveness.

43 PARTICLE ACCELERATORS↗

Technological Issues and High Gradient Test Results on X-Band Molybdenum Accelerating Structures

Two 11.424 GHz single cell standing wave accelerating structures have been fabricated for high gradient RF breakdown studies. Both are brazed structures: one made from copper and the other from sintered molybdenum bulk. The tests results are presented and compared to those of similar devices constructed at SLAC (Stanford Linear Accelerator Center) and KEK (Ko Enerugi Kasokuki Kenkyu Kiko). The technological issues to build both sections are discussed.

43 PARTICLE ACCELERATORS↗

Compact, high-efficiency accelerators driven by low-voltage solid-state amplifiers

A compact particle accelerator can include two or more cavities disposed along an axis of the particle accelerator, each of which is coupled to two or more drivers. The accelerator can also include a power supply coupled to the two or more drivers such that a particle beam traveling along the axis is accelerated. The power supply can be an interface with a commercial power outlet, battery power, or a combination thereof depending upon the use case. Example configurations of the accelerator include hand held or mobile devices that are capable of delivering up to and greater than a 1 MeV electron beam.

42 ENGINEERING↗

Compact, high-efficiency accelerators driven by low-voltage solid-state amplifiers

A compact particle accelerator can include two or more cavities disposed along an axis of the particle accelerator, each of which is coupled to two or more drivers. The accelerator can also include a power supply coupled to the two or more drivers such that a particle beam traveling along the axis is accelerated. The power supply can be an interface with a commercial power outlet, battery power, or a combination thereof depending upon the use case. Example configurations of the accelerator include hand held or mobile devices that are capable of delivering up to and greater than a 1 MeV electron beam.

Nguyen, Dinh Cong↗

Pulsed-Focusing Recirculating Linacs for Muon Acceleration

Neutrino Factories and Muon Colliders require rapid acceleration of short-lived muons to multi-GeV and TeV energies. A Recirculating Linear Accelerator (RLA) that uses International Linear Collider (ILC) RF structures can provide exceptionally fast and economical acceleration to the extent that the focusing range of the RLA quadrupoles allows each muon to pass several times through each high-gradient cavity. A new concept of rapidly changing the strength of the RLA focusing quadrupoles as the muons gain energy is being developed to increase the number of passes that each muon will make in the RF cavities, leading to greater cost effectiveness. We discus the optics and technical requirements for RLA designs, using RF cavities capable of simultaneous acceleration of both mu+ and mu- species, with pulsed Linac quadrupoles to allow the maximum number of passes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Latest Progress in Designs and Testings of PIP-II Power Couplers

Proton Improvement Plan – II (PIP-II) project is under go in Fermi National Laboratory. Main part of the project is 800 MeV proton superconducting accelerator which includes 116 superconducting cavities of 5 different types and three 162.5, 325 and 650 MHz frequencies. Key elements of accelerator which determine a reliable operation are main couplers for superconducting cavities. This paper describes the latest progress in design and testing of main couplers for PIP-II projects.

43 PARTICLE ACCELERATORS↗

AASC Coated Cavities

The price of niobium is a significant part of the cost of superconducting RF cavity production. One route to significant cost reduction is to use cavities that have a thin layer of niobium deposited on a less expensive substrate. However, to date, all attempts to use thin films of niobium in superconducting RF cavities have resulted in cavity performance that does not meet the requirements for modern linear accelerators. Fermilab will provide two (2) cavities to AASC. AASC will coat the two (2) cavities with niobium using its high-purity deposition method. AASC will return the coated cavities to Fermilab for Quality Assurance (QA) testing. If the coatings pass preliminary QA tests performed at Fermilab, they will be subjected to RF testing at Fermilab and their performance will be evaluated relative to solid niobium cavities.

43 PARTICLE ACCELERATORS↗

Nb3Sn Multilayer Sequential Sputtering at Jefferson Lab

Nb3Sn-coated Nb SRF cavities are studied due to their potential of providing a higher accelerating gradient over Nb SRF cavities. Magnetron sputtering can be a feasible alternative to conventional tin vapor diffusion process to fabricate Nb3Sn for SRF cavities. By depositing Nb and Sn layers separately and annealing afterwards, the stoichiometry of the coated films can be controlled to create Nb3Sn. To understand the formation of Nb3Sn at higher annealing temperatures, a comparative study of deposition and processing conditions is required. We have sputtered Nb and Sn multilayers and post-deposition annealed at 850, 950, 1000, 1100 and 1200 °C for 3 hours. The structural properties of the annealed films were characterized by X-ray diffraction (XRD) and compared to as-coated films. The film microstructures and compositions were examined by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). The superconducting transition of the films were measured by surface resistivity data obtained down to cryogenic temperatures. A new cavity deposition system with a cylindrical magnetron has been designed to implement the sequential sputtering technique onto a single-cell cavity.

Eremeev, Grigory↗

High-gradient two-beam electron accelerator

The main goal for this project was to design, build, and evaluate a detuned-cavity, collinear, two-beam accelerator structure. Testing was to be at the Yale University Beam Physics Laboratory, under terms of a sub-grant from Omega-P to Yale. Facilities available at Yale for this project include a 6-MeV S-band RF gun and associated beam line for forming and transporting a ~1 A drive beam , a 300 kV beam source for use as a test beam, and a full panoply of laboratory infrastructure and test equipment. During the first year of this project, availability and functionality of the 6-MeV drive beam and 300 kV test beam were confirmed, and the beam line was restored to a layout to be used with the two-beam accelerator project. Major efforts during the first year were also focused on computational design and simulation of the accelerator structure itself, on beam dynamics, and on beam transport. Effort during the second year was focussed on building and preparing to test the structure, including extensive cold testing. Detailed results from work under this project have been published in twelve archival journal articles, listed in Section IV of the technical report.

43 PARTICLE ACCELERATORS↗

STANDARDIZATION OF CEBAF 12 GEV UPGRADE CAVITY TESTING

CEBAF 12GeV upgrade project includes 80 new 7-cell cavities to form 10 cryomodules. Each cavity underwent RF qualification at 2.07K using a high power accelerating gradient test and an HOM survey in Jefferson Lab's Vertical Testing Area (VTA) before cavity string assembly. In order to ensure consistently high quality data, updated cavity testing procedures and analysis were implemented and used by a group of VTA operators. For high power tests, a cavity testing procedure was developed and used in conjunction with a LabVIEW program to collect the test data. Additionally while the cavity was at 2.07K, an HOM survey was performed using a network analyzer and a combination of Excel and Mathematica programs. Data analysis was standardized and an online logbook, Pansophy, was used for data storage and mining. The Pansophy system allowed test results to be easily summarized and searchable across all cavity tests. In this presentation, the CEBAF 12GeV upgrade cavity testing procedure, method for data analysis, and results reporting results will be discussed.

43 PARTICLE ACCELERATORS↗

A High Power CW Input Coupler with Reduced Static and Dynamic Losses

Each niobium cavity employed in superconducting accelerators requires a power coupler that supplies it with up to hundreds of kW’s of CW RF power, which is delivered to the 2K or 4K cold cavity from a Room Temperature (RT) source. Coupler design is a challenging task. It should transmit the minimum possible thermal power flow to the cavity, because a single watt at 2K requires 1 kW of cryogenic system power to remove it. Since the coupler connects the cold cavity to a Room Temperature (RT) power source, it transmits a static thermal load due to its thermal conductivity. Also, the coupler experiences heating by RF fields. This dissipated power partially penetrates to the 2K zone, and is called a dynamic load. From one point of view, the coupler should have low thermal conductivity, in order to decrease the static load. Stainless steel (SS) is usually used for that reason, but it also has low electrical conductivity, which introduces a high dynamic load. Copper plating on the SS is required to improve the electrical conductivity, but it is not reliable and often flakes. One copper flake might cause an electrical discharge and contaminate the surface of the niobium cavity, thus spoiling its Q-factor. In that case, decommissioning of the entire cryomodule is required to restore the cavity Q-factor, which means it is a tremendously expensive procedure. That is why an improved reliability coupler is of very high interest. As a result, the main idea of the proposed project is to completely eliminate the unreliable copper plating by employing solid copper shields to screen the SS pipe from RF fields.

43 PARTICLE ACCELERATORS↗

Rugged Ceramic Window for RF Applications – Phase 1

High-current RF cavities that are needed for many accelerator applications are often limited by the power transmission capability of the pressure barriers (windows) that separate the cavity from the power source. Most efforts to improve RF window design have focused on alumina ceramic, the most popular historical choice, and have not taken advantage of new materials. Alternative window materials have been investigated using a novel Merit Factor comparison and likely candidates have been tested for the material properties which will enable construction in the self-matched window configuration. Window assemblies have also been modeled and fabricated using compressed window techniques which have proven to increase the power handling capability of waveguide windows. Candidate materials have been chosen to be used in fabricating a window for high power testing at Thomas Jefferson National Accelerator Facility.

43 PARTICLE ACCELERATORS↗

PERLE: A High Power Energy Recovery Facility

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab is the first large high power CW recirculating electron accelerator to make use of SRF accelerating structures. The structures are configured in two anti-parallel linacs connected by arcs. Each linac consists of twenty C20/C50 cryomodules each containing eight 5-cell cavities and five C100 upgrade cryomodules each containing eight 7-cell cavities. Accurately classifying the source of cavity faults is critical for improving accelerator performance. A cavity fault triggers a waveform acquisition process where 17 waveform records sampled at 5 kHz are recorded for each of the 8 cavities in the affected cryomodule. The waveform record length is sufficiently long for transient microphonic effects to be observable. This data combined with archived signals sampled at 10 Hz are used to classify faults. Significant time is required for a subject matter expert to analyze and identify the intra-cavity signatures of imminent faults. This paper describes a path forward that utilizes machine learning for automatic fault classification. Post-training identification of the physical origins of faults are discussed, as are potential machine-trained model-free implementations of trip avoidance procedures. These methods should provide new insights into cavity fault mechanisms and facilitate intelligent optimization of cryomodule performance

Kaabi, W.↗

Airloads near the open port of a one-meter airborne telescope

An infrared telescope is mounted in a cavity in the fuselage of a C-141 airplane. The cavity is sealed off from the rest of the fuselage and can be opened to the outside for viewing. A retractable porous spoiler is installed ahead of the opening to inhibit cavity resonance. The paper presents the mean pressures, pressure fluctuations, spectra, phase, and coherence of the pressures in the cavity and on the fuselage near the cavity, along with pertinent acceleration and torque information for the aircraft structure and telescope. It is shown that a moderate spoiler extension controls resonance in normal flight attitudes and produces a cavity environment with approximately the same turbulence intensity as an attached turbulent boundary layer.

Buell, D. A.↗

Test of a coaxial blade tuner at HTS FNAL

A coaxial blade tuner has been selected for the 1.3GHz SRF cavities of the Fermilab SRF Accelerator Test Facility. Results from tuner cold tests in the Fermilab Horizontal Test Stand are presented. Fermilab is constructing the SRF Accelerator Test Facility, a facility for accelerator physics research and development. This facility will contain a total of six cryomodules, each containing eight 1.3 GHz nine-cell elliptical cavities. Each cavity will be equipped with a Slim Blade Tuner designed by INFN Milan. The blade tuner incorporates both a stepper motor and piezo actuators to allow for both slow and fast cavity tuning. The stepper motor allows the cavity frequency to be statically tuned over a range of 500 kHz with an accuracy of several Hz. The piezos provide up to 2 kHz of dynamic tuning for compensation of Lorentz force detuning and variations in the He bath pressure. The first eight blade tuners were built at INFN Milan, but the remainder are being manufactured commercially following the INFN design. To date, more than 40 of the commercial tuners have been delivered.

43 PARTICLE ACCELERATORS↗