Search NASA⌕ Search

SEARCH · Search NASA

Results for “Acceleration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 811 records · Page 45

TH-EF-204-02: Small Field Radiation Therapy: Physics and Recent Recommendations From IAEA and ICRU

Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment delivery systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in contrast to dosimetry of conventional fields To learn about detectors suitable for small fields To learn about the role of Monte Carlo simulations in determination of small field output factors To provide an overview of the IAEA small field dosimetry recommendations To provide an overview of the content of the ICRU report on Prescribing, Reporting and Recording of Small Field Radiation Therapy. To learn about special technical considerations in delivering IMRT and SBRT treatments To appreciate specific challenges of IMRT implementation J. Seuntjens, Natural Sciences and Engineering Research Council; Canadian Institutes of Health Research.

60 APPLIED LIFE SCIENCES↗

TH-EF-204-03: Determination of Small Field Output Factors, Advantages and Limitations of Monte Carlo Simulation

Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment delivery systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in contrast to dosimetry of conventional fields To learn about detectors suitable for small fields To learn about the role of Monte Carlo simulations in determination of small field output factors To provide an overview of the IAEA small field dosimetry recommendations To provide an overview of the content of the ICRU report on Prescribing, Reporting and Recording of Small Field Radiation Therapy. To learn about special technical considerations in delivering IMRT and SBRT treatments To appreciate specific challenges of IMRT implementation J. Seuntjens, Natural Sciences and Engineering Research Council; Canadian Institutes of Health Research.

60 APPLIED LIFE SCIENCES↗

TH-EF-204-04: Experience of IMRT and Other Conformal Techniques in Russia

Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment delivery systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in contrast to dosimetry of conventional fields To learn about detectors suitable for small fields To learn about the role of Monte Carlo simulations in determination of small field output factors To provide an overview of the IAEA small field dosimetry recommendations To provide an overview of the content of the ICRU report on Prescribing, Reporting and Recording of Small Field Radiation Therapy. To learn about special technical considerations in delivering IMRT and SBRT treatments To appreciate specific challenges of IMRT implementation J. Seuntjens, Natural Sciences and Engineering Research Council; Canadian Institutes of Health Research.

60 APPLIED LIFE SCIENCES↗

TH-EF-204-05: Application of Small-Field Treatment: The Promises and Pitfalls of SBRT

Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment delivery systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in contrast to dosimetry of conventional fields To learn about detectors suitable for small fields To learn about the role of Monte Carlo simulations in determination of small field output factors To provide an overview of the IAEA small field dosimetry recommendations To provide an overview of the content of the ICRU report on Prescribing, Reporting and Recording of Small Field Radiation Therapy. To learn about special technical considerations in delivering IMRT and SBRT treatments To appreciate specific challenges of IMRT implementation J. Seuntjens, Natural Sciences and Engineering Research Council; Canadian Institutes of Health Research.

60 APPLIED LIFE SCIENCES↗

TH-EF-204-06: Closing

Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT). SRT is characterized by sharp dose gradients for individual fields and their resultant dose distributions. For appropriate targets, small field radiotherapy offers improved treatment quality by allowing better sparing of organs at risk while delivering the prescribed target dose. Specialized small field treatment delivery systems, such as robotic-controlled linear accelerators, gamma radiosurgery units, and dynamic arc linear accelerators may utilize rigid fixation, image guidance, and tumor tracking, to insure precise dose delivery to static or moving targets. However, in addition to great advantages, small field delivery techniques present special technical challenges for dose calibration due to unique geometries and small field sizes not covered by existing reference dosimetry protocols such as AAPM TG-51 or IAEA TRS 398. In recent years extensive research has been performed to understand small field dosimetry and measurement instrumentation. AAPM, IAEA and ICRU task groups are expected to provide soon recommendations on the dosimetry of small radiation fields. In this symposium we will: 1] discuss the physics, instrumentation, methodologies and challenges for small field radiation dose measurements; 2] review IAEA and ICRU recommendations on prescribing, recording and reporting of small field radiation therapy; 3] discuss selected clinical applications and technical aspects for specialized image-guided, small field, linear accelerator based treatment techniques such as IMRT and SBRT. Learning Objectives: To learn the physics of small fields in contrast to dosimetry of conventional fields To learn about detectors suitable for small fields To learn about the role of Monte Carlo simulations in determination of small field output factors To provide an overview of the IAEA small field dosimetry recommendations To provide an overview of the content of the ICRU report on Prescribing, Reporting and Recording of Small Field Radiation Therapy. To learn about special technical considerations in delivering IMRT and SBRT treatments To appreciate specific challenges of IMRT implementation J. Seuntjens, Natural Sciences and Engineering Research Council; Canadian Institutes of Health Research.

60 APPLIED LIFE SCIENCES↗

Experimental studies of the magnetic structure and plasma dynamics in current sheets (a review)

Based on measurements of magnetic fields in current sheets, spatial distributions of the electric current and electrodynamic forces in successive stages of the sheet evolution are determined. Two new effects manifesting themselves mostly in the late stages of the current sheet evolution have been discovered, namely, expansion of the current flow region at the periphery of the sheet and the appearance of a region with inverse currents, which gradually expands from the periphery toward the center of the sheet. Using spectroscopic methods, generation of superthermal plasma flows accelerated along the sheet width from the center toward the periphery has been revealed and investigated. The measured energies of accelerated plasma ions satisfactorily agree with the Ampère forces determined from magnetic measurements. The excitation of inverse currents additionally confirms the motion of high-speed plasma flows from the center of the current sheet toward its side edges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A performance model for the communication in fast multipole methods on high-performance computing platforms

Exascale systems are predicted to have approximately 1 billion cores, assuming gigahertz cores. Limitations on affordable network topologies for distributed memory systems of such massive scale bring new challenges to the currently dominant parallel programing model. Currently, there are many efforts to evaluate the hardware and software bottlenecks of exascale designs. It is therefore of interest to model application performance and to understand what changes need to be made to ensure extrapolated scalability. The fast multipole method (FMM) was originally developed for accelerating N-body problems in astrophysics and molecular dynamics but has recently been extended to a wider range of problems. Its high arithmetic intensity combined with its linear complexity and asynchronous communication patterns make it a promising algorithm for exascale systems. In this paper, we discuss the challenges for FMM on current parallel computers and future exascale architectures, with a focus on internode communication. We focus on the communication part only; the efficiency of the computational kernels are beyond the scope of the present study. We develop a performance model that considers the communication patterns of the FMM and observe a good match between our model and the actual communication time on four high-performance computing (HPC) systems, when latency, bandwidth, network topology, and multicore penalties are all taken into account. To our knowledge, this is the first formal characterization of internode communication in FMM that validates the model against actual measurements of communication time. The ultimate communication model is predictive in an absolute sense; however, on complex systems, this objective is often out of reach or of a difficulty out of proportion to its benefit when there exists a simpler model that is inexpensive and sufficient to guide coding decisions leading to improved scaling. The current model provides such guidance.

Computer Science↗

Comparison of nested geometry treatments within GPU-based Monte Carlo neutron transport simulations of fission reactors

Monte Carlo (MC) neutron transport provides detailed estimates of radiological quantities within fission reactors. This involves tracking individual neutrons through a computational geometry. CPU-based MC codes use multiple polymorphic tracker types with different tracking algorithms to exploit the repeated configurations of reactors, but virtual function calls have high overhead on the GPU. The Shift MC code was modified to support GPU-based tracking with three strategies: dynamic polymorphism with virtual functions, static polymorphism, and a single tracker type with tree-based acceleration. On the Frontier supercomputer these methods achieve 77.8%, 91.2%, and 83.4%, respectively, of the tracking rate obtained using a specialized tracker optimized for rectilinear-grid-based reactors. This indicates that all three methods are suitable for typical reactor problems in which tracking does not dominate runtime. The flexibility of the single tracker method is highlighted with a hexagonal-grid microreactor problem, performed without hexagonal-grid-specific tracking routines, providing a 2.19× speedup over CPU execution.

97 MATHEMATICS AND COMPUTING↗

Efficient method for the measurement of lifetime optical damage performance of thin film coatings from laser damage size analysis

Here, a laser damage test method based on damage size analysis (DSA) is described that simplifies the derivation of the lifetime optical damage threshold of film materials critical in the design of devices used in high-repetition-rate, high-power laser systems. The DSA method presented here is solely based on imaging to measure the damage site size produced from exposure to a known Gaussian-shaped beam with a fixed, systematically selected fluence well above the ablation threshold. The method locates the damage boundary produced from repeated exposures, using images with a high contrast, and maps it to the beam profile to extract a lifetime laser damage fluence threshold value. We validate the DSA approach using a few relevant transparent film material systems and by comparing it to the standard S /1 laser damage test method. The DSA method can be more efficient and accelerate materials development and validation necessary to support the design of high-power repetition-rated lasers and optoelectronic devices.

36 MATERIALS SCIENCE↗

Precision engineering of biological function with large-scale measurements and machine learning

As synthetic biology expands and accelerates into real-world applications, methods for quantitatively and precisely engineering biological function become increasingly relevant. This is particularly true for applications that require programmed sensing to dynamically regulate gene expression in response to stimuli. However, few methods have been described that can engineer biological sensing with any level of quantitative precision. Here, we present two complementary methods for precision engineering of genetic sensors: in silico selection and machine-learning-enabled forward engineering. Both methods use a large-scale genotype-phenotype dataset to identify DNA sequences that encode sensors with quantitatively specified dose response. First, we show that in silico selection can be used to engineer sensors with a wide range of dose-response curves. To demonstrate in silico selection for precise, multi-objective engineering, we simultaneously tune a genetic sensor’s sensitivity (EC 50 ) and saturating output to meet quantitative specifications. In addition, we engineer sensors with inverted dose-response and specified EC 50 . Second, we demonstrate a machine-learning-enabled approach to predictively engineer genetic sensors with mutation combinations that are not present in the large-scale dataset. We show that the interpretable machine learning results can be combined with a biophysical model to engineer sensors with improved inverted dose-response curves.

59 BASIC BIOLOGICAL SCIENCES↗

High-dimensional maximum-entropy phase space tomography

Reconstructing 4D or 6D phase space distributions from 1D or 2D measurements is a challenging inverse problem encountered in particle accelerators. Entropy maximization is an established method to incorporate prior information in the reconstruction, but it is typically infeasible in high-dimensional spaces. In this paper, I review two recent approaches to high-dimensional entropy maximization. The first approach utilizes differentiable simulations and a class of generative models known as normalizing flows, whereas the second approach employs the method of Lagrange multipliers and Markov Chain Monte Carlo (MCMC) sampling. My aim is to provide a short explanation of each method using a common notation. I conclude by mentioning several unsolved problems in phase space tomography.

Hoover, Austin [ORNL] (ORCID:0000000153136962)↗

Modeling Long-term Creep Performance for Welded Nickel-base Superalloy Structures for Power Generation Systems

The goal of this project is to model long-term creep performance for nickel-base superalloy weldments in high temperature power generation systems. The project uses physics-based modeling methodologies and algorithms for predicting alloy properties in heterogeneous material structures. The modeling methodology will be demonstrated on a gas turbine combustor liner weldment of Haynes 282 precipitate-strengthened nickel-base superalloy. The major developments are: (1) microstructure-property relationships under creep conditions and microstructure characterization (2) modeling inhomogeneous microstructure in superalloy weld (3) modeling mesoscale plastic deformation in superalloy weld and (4) a constitutive creep model that accounts for weld and base metal microstructure and their long term evolution. The developed modeling technology is aimed to provide a more efficient and accurate assessment of a material’s long-term performance compared with current testing and extrapolation methods. This modeling technology will also accelerate development and qualification of new materials in advanced power generation systems. This document is a final technical report for the project, covering efforts conducted from October 2014 to December 2016.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of High-Performance Cast Crankshafts. Final Technical Report

The objective of this project was to develop technologies that would enable the production of cast crankshafts that can replace high performance forged steel crankshafts. To achieve this, the Ultimate Tensile Strength (UTS) of the new material needs to be 850 MPa with a desired minimum Yield Strength (YS; 0.2% offset) of 615 MPa and at least 10% elongation. Perhaps more challenging, the cast material needs to be able to achieve sufficient local fatigue properties to satisfy the durability requirements in today’s high performance gasoline and diesel engine applications. The project team focused on the development of cast steel alloys for application in crankshafts to take advantage of the higher stiffness over other potential material choices. The material and process developed should be able to produce high-performance crankshafts at no more than 110% of the cost of current production cast units, perhaps the most difficult objective to achieve. To minimize costs, the primary alloy design strategy was to design compositions that can achieve the required properties with minimal alloying and post-casting heat treatments. An Integrated Computational Materials Engineering (ICME) based approach was utilized, rather than relying only on traditional trial-and-error methods, which has been proven to accelerate alloy development time. Prototype melt chemistries designed using ICME were cast as test specimens and characterized iteratively to develop an alloy design within a stage-gate process. Standard characterization and material testing was done to validate the alloy performance against design targets and provide feedback to material design and manufacturing process models. Finally, the project called for Caterpillar and General Motors (GM) to develop optimized crankshaft designs using the final material and manufacturing processing path developed. A multi-disciplinary effort was to integrate finite element analyses by engine designers and geometry-specific casting simulations with existing materials models to optimize crankshaft cost and performance. Prototype crankshafts of the final design were to be produced and validated using laboratory bench testing and on-engine durability testing. ICME process simulation tools were used to investigate a broad range of processing concepts. These concepts included casting orientation, various mold and core materials, and various filling and feeding strategies. Each crankshaft was first simulated without gating and risers, which is termed natural solidification. The natural solidification results were used as a baseline for strategy development of each concept. Casting process simulations and ICME tools were proven to be reasonable predictors of real world results. Potential alloys were developed that could meet the project material property goals with appropriate normalization and temper treatments. For the alloys considered, post-normalization temper treatments proved to be necessary to achieve the desired yield strengths and elongations and appropriate heat treatments were designed using ICME tools. The experimental data of all the alloys were analyzed in combination with ICME tools to establish chemistry-process-structure relations. Several GM small gas engine (SGE) crankshafts were successfully cast in sand molds using two different sprue, runner, gate, riser, chill designs. These crankshafts were cast in two different steel alloys developed during the project, but casting finishing (e.g. riser removal) remains a cost challenge. A long list of future work was left unfinished when this project was unexpectedly terminated.

36 MATERIALS SCIENCE↗

The Michigan New Technology Training and Research (MNTR) Translational Program in Nuclear Medicine (Final Report)

The Michigan New Technology Training and Research (MNTR) Translational Program in Nuclear Medicine and Molecular Imaging This project established the Michigan New Technology Training and Research (MNTR) translational program, focused on the acceleration of new clinical molecular imaging methods. Molecular imaging approaches to imaging are a very flexible and powerful development, with many recent examples advancing the diagnosis and guiding the management of human disease. These methods depend on the design, synthesis and testing of new radiotracers (molecules designed to target specific cells or tissues in the body), labeled with short-lived radioactive atoms (positron emitters). The new radiotracers are imaged in the human body using positron emission tomography (PET) imaging. The University of Michigan PET Center has considerable experience in the discovery, development, refinement and initial human applications of new PET radiotracers. An emerging impediment to efficient availability of new PET radiotracers, however, involves the regulatory environment at multiple levels. Many potentially successful ideas are delayed or even prevented from entering human use by these barriers. In the current grant, we provided hands-on experience for the next generation of young scientists working in molecular imaging so that they are equipped to effectively move new ideas and radiotracers from the research laboratory to the nuclear medicine clinic (bench-to-bedside). For new radiotracer development, oversight by the Food and Drug Administration (FDA), the Nuclear Regulatory Commission (NRC), and local institutional committees and reviews are required. These aspects of translation from laboratory to clinic are often omitted from the formal training of new scientists, but were provided to three trainees via direct mentorship in the MNTR program. The MNTR training program built on the translational successes of the University of Michigan Division of Nuclear Medicine and capitalized on our strengths (facilities, faculty, a wide-ranging selection of projects, and the experience and commitment to bring new radiotracers into human studies) to systematically train three fellows in radiochemistry and nuclear medicine. Integrated training in development, validation and clinical translation of new PET radiotracers occurred through practical involvement in multiple research projects, each at a different stage along the pathway from bench-to-bedside. Each trainee obtained experience of the entire process over about 2 years. Projects involved development of new radiotracers for neurodegenerative disorders (e.g. Alzheimer disease), movement disorders (e.g. Parkinson disease, progressive supranuclear palsy) and neurodevelopmental syndromes (e.g. Tourette syndrome) as well as new radiochemistry methods for synthesizing radiotracers. Each project was pursued in a close collaboration between the fellow trainee and both the clinical and basic science faculty at the University of Michigan PET Center, and provided an unprecedented opportunity for the highest-level training in academic radiochemistry and nuclear medicine research. The project has resulted in 17 peer-reviewed publications to date, and at least 4 more are in preparation. Additionally, 1 book chapter and 26 conference presentations have resulted from this grant. Upon completion of the MNTR Program, the trainees have emerged as translational scientists wielding the necessary skill-set (practical research experience, multidisciplinary training, regulatory know-how) to embark on successful careers in translational molecular imaging, bringing continued advances in the field to bear on important human disorders. As a metric of the Program’s success, one fellow has already secured employment in the field, while the other two are finishing writing papers; they wish to also stay in the radiochemistry and nuclear medicine community, and are currently applying for jobs.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A large-scale benchmarking of deterministic and stochastic derivative-free optimization algorithms

This presentation summarizes our work in the PrOMMiS project on benchmarking of data-driven optimization algorithms and their applications in self-driving laboratories. This work supports the broader project goal of accelerating the identification of promising separation methods and operating conditions for critical minerals separation processes. We present a systematic benchmarking study of 42 data-driven optimization algorithms on a broad collection of 502 test problems. The results identify BAM, GLCCLUSTER, and MULTIMIN as the most effective optimization solvers, with BAM showing the highest overall performance and solving more than 80% of the benchmark problems. The study also shows that no single solver consistently outperforms the others across all problem types, indicating that our future laboratory applications may benefit from using a small set of strong solvers rather than relying on a single method. The presentation also illustrates an in-silico chemical reactor case study showing that data-driven optimization methods can guide autonomous experimentation in a self-driving laboratory and identify optimal operating conditions within a small number of experiments. Overall, the results provide a basis for selecting efficient optimization methods and demonstrate the practical use of data-driven optimization in self-driving laboratory workflows.

36 MATERIALS SCIENCE↗

Algorithm-guided experimentation for autonomous AI systems in self-driving laboratories

This presentation summarizes our work in the PrOMMiS project on benchmarking of data-driven optimization algorithms and their applications in self-driving laboratories. This work supports the broader project goal of accelerating the identification of promising separation methods and operating conditions for critical minerals separation processes. We present a systematic benchmarking study of 42 data-driven optimization algorithms on a broad collection of 502 test problems. The results identify BAM, GLCCLUSTER, and MULTIMIN as the most effective optimization solvers, with BAM showing the highest overall performance and solving more than 80% of the benchmark problems. The study also shows that no single solver consistently outperforms the others across all problem types, indicating that our future laboratory applications may benefit from using a small set of strong solvers rather than relying on a single method. The presentation also illustrates an in-silico chemical reactor case study showing that data-driven optimization methods can guide autonomous experimentation in a self-driving laboratory and identify optimal operating conditions within a small number of experiments. Overall, the results provide a basis for selecting efficient optimization methods and demonstrate the practical use of data-driven optimization in self-driving laboratory workflows.

36 MATERIALS SCIENCE↗

Design Criteria for High-Gradient Radio-Frequency Linacs

This article will review methods used at the SLAC National Accelerator Laboratory and other world accelerator laboratories to design high-gradient normal conducting accelerating structures. A quest for compact radio-frequency linacs fueled decades of studies toward a higher accelerating gradient. A major phenomena limiting the increase of the gradient is vacuum radio-frequency breakdown; therefore, this paper will address the breakdown physics and discuss approaches that reduce the breakdown probability. This discussion will cover both the electrical design and fabrication technology of the accelerating structures to achieve practical operating accelerating gradients in excess of 100 MV/m. Most of the data described here were obtained during the development of 11 GHz linacs for electron–positron linear colliders, so extrapolation of the results to other frequencies should be performed cautiously.

Dolgashev, Valery A. (ORCID:0000000166715402)↗

Beam echoes in the presence of coupling

Transverse beam echoes could provide a new technique of measuring diusion characteristics orders of magnitude faster than the current methods; however, their interaction with many accelerator parameters is poorly understood. Using a program written in C, we explored the relationship between coupling and echo strength. We found that echoes could be generated in both dimensions, even with a dipole kick in only one dimension. We found that the echo eects are not destroyed even when there is strong coupling, falling o only at extremely high coupling values. We found that at intermediate values of skew quadrupole strength, the decoherence time of the beam is greatly increased, causing a destruction of the echo eects. We found that this is caused by a narrowing of the tune width of the particles. Results from this study will help to provide recommendations to IOTA (Integrable Optics Test Accelerator) for their upcoming echo experiment.

43 PARTICLE ACCELERATORS↗